HHC Hand-Held Communicator. User s Guide
|
|
- Gregory Burns
- 5 years ago
- Views:
Transcription
1 HHC Hand-Held Communicator Siemens Energy, Inc. Oil & Gas Solutions Telge Road Houston, Texas USA Document No.: SEI-OG-DLS-002 Page 1 of 9 Siemens AG 2010
2 Description: The is used for field service and configuration of the Siemens Digital Level Sensor. It is powered by four (4) AA type Batteries and generates 12V 70mA power for a single sensor or external power, and can be used for communicating with multiple sensors. A picture of the HHC-1000 is shown in Figure 1. Pin connections are shown in Figure 2. Commands: After turning the unit ON, the will appear. The following commands may then be used to configure the level sensing system. The screens shown apply to Software Version Unit Number F1 Set Points F2 Data Request F3 System Read Set Points Press 1 to set the HHC to Sensor Unit # F1 = Set Points Menu *Status Line Battery Voltage, Alpha Indicator, Current System Unit Number and Baud Rate. F1 SET POINTS F1 Communications F2 Level F3 Temperature 4-20 ma Set Points Commands F1 = Communications sub-menu F2 = Level sub-menu F3 = Temperature sub-menu = 4_20 ma sub-menu Document No.: SEI-OG-DLS-002 Page 2 of 9 Siemens AG 2010
3 F1/F1 COMMUNCATIONS F1 Search For Sensor F2 Baud Rate F3 Rx To Tx Delay Assign Unit Number Communication Commands F1 = Searches for Sensor with unknown unit number F2 = Set the Sensor Baud Rate F3 = Set Rx to Tx Time Delay = Address Sensor Unit Number F1/F2 Level Commands LEVEL F1 Number of Floats F2 Level Offset F3 F1 = Set the Number of floats F2 = Set the Level Offset Document No.: SEI-OG-DLS-002 Page 3 of 9 Siemens AG 2010
4 F1/F3 Temperature Commands TEMPERATURE F1 F2 Temp Offset F3 F2 = Set Temperature offset F1/ 4_20mA F1 Poll Period F2 4_20mA Min F3 4_20mA Max 4_20ma Commands F1 = Set polling period for 4_20 board F2 = Set minimum level for 4 ma F3 = Set maximum level for 20mA Document No.: SEI-OG-DLS-002 Page 4 of 9 Siemens AG 2010
5 1 Unit Number F1 Set Points F2 Data Request F3 System Read Set Points F2 = Data Request Menu F2 Data Request F1 Level & Temp F2 Level & Temp Cont. F3 4_20mA Output Version Data Request Commands F1 = Display Level and Temperature F2 = Continuous Display of Level and Temperature F3 = 4_20mA Engineering Value = Sensor Software Version Document No.: SEI-OG-DLS-002 Page 5 of 9 Siemens AG 2010
6 1 Unit Number F1 Set Points F2 Data Request F3 System Read Set Points F3 = System Menu F3 SYSTEM F1 Read Mode F2 Terminal F3 Backlight Timer System Commands F1 = Read Mode (either Smart or Real) F2 = Terminal for custom commands F3 = Setup for Timer (Max 90sec) Document No.: SEI-OG-DLS-002 Page 6 of 9 Siemens AG 2010
7 1 Unit Number F1 Set Points F2 Data Request F3 System Read Set Points = Read Set Points Menu READ SET POINTS 1 F1 Number Of Floats F2 Level Offset F3 Temperature Offset MORE Read Set Points 1 Commands F1 = Read Number of Floats F2 = Read Level Offsets F3 = Read Temperature Offsets = More sub-menu / Read Set Points 2 Commands READ SET POINTS 2 F1 Switch Distance F2 Total Switches F3 Rx to Tx Delay 4_2-mA Config F1 = Read Switch Distance F2 = Read Total Switches F3 = Read Rx to Tx Display = 4_20mA Configuration Document No.: SEI-OG-DLS-002 Page 7 of 9 Siemens AG 2010
8 Special Commands: Increase Contrast - Press and hold ENTER and Tap + key. Decrease Contrast - Press and hold ENTER and Tap - key. Turn Backlight ON - Press ENTER and UP ARROW Turn Backlight OFF - Press ENTER and DN ARROW Hidden Keyboard Symbols, in NUMERIC mode: X =? U = * HHC-100 Specifications: Communication: 4 or 2 wire RS485 interface, 1200 and 9600 Baud Rate. Power: 4 AA type batteries, or External 12VDC. Display: LCD (128x64) with back light and front panel contrast adjustment. Other: Auto POWER-OFF after 3 minutes (10 second warning) Document No.: SEI-OG-DLS-002 Page 8 of 9 Siemens AG 2010
9 Figure 1 Figure 2 HHC-1000 Pin Connections Contact Information: For further information or for assistance, please contact: Siemens Energy, Inc. Oil & Gas Solutions Telge Road Houston, TX Phone: +1 (888) or +1 (281) oilandgaslcm.energy@siemens.com Document No.: SEI-OG-DLS-002 Page 9 of 9 Siemens AG 2010
INSTRUCTION MANUAL R.C. SYSTEMS CO. INC. WaveNet Site Survey Tool
INSTRUCTION MANUAL R.C. SYSTEMS CO. INC. WaveNet Site Survey Tool Warning: Read & understand contents of this manual prior to operation. Failure to do so could result in serious injury or death. PH. 409-986-9800
More informationTX-1AA TRANSMITTER. Note:
TX-1AA TRANSMITTER Physical Dimensions: 2.95 x 1.07 Power Requirements: 1 AA Cell Alkaline Typical Duration: 30 Hours Maximum Duration: 70 Hours Free Air Range Test: 20 Feet This transmitter can be programmed
More informationBandMaster V Manual. Installation
BandMaster V Manual Installation Installing and configuring the BM-5 BandMaster V is a simple process. All the configuration process is done from the front panel. Installation and configuration steps are
More informationMate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater
Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater For additional information contact matedev@outbackpower.com Page 1 of 20 Revision History Revision 2.0:
More informationAddendum 1.4_2. (Addendum to MX420 Operator s Manual)
_2 (Addendum to MX420 ) September, 2007 Table of Contents About this document..1 MX575 Heading & Rate of Turn 2 MX575 as a D/GPS Compass only 2 MX575 as a D/GPS Compass with Navigation Functionality.....4
More informationOperator Manual 1.4 FRACSIM MINI
FracSim Meters FracSim Meters was founded with the intention of providing specifically designed tools for the well service industry. Our goal is to provide quality tools with a robust design to meet the
More information9320 Manual Portable Battery Powered Indicator
9320 Manual Portable Battery Powered Indicator Interface, Inc. 7401 E. Butherus Dr. Scottsdale, AZ 85260 800-947-5598 480-948-1924 (fax) www.interfaceforce.com CONTENTS INTRODUCTION...2 USER OPERATION...2
More informationHub and Cluster. ogramming Manual. Pro MAN3090
Hub and Cluster Pro ogramming Manual MAN3090 Contents Introduction 3 Radio Channels 28 System Overview 3 Currently Used 30 RCC RCC Ch 30 System Design 4 Device RCC Ch 30 Manual Select 30 Compatibility
More information10 Amperes max. test current Micro-Ohm Meter Model : MO-2014 OPERATION MANUAL
10 Amperes max. test current Micro-Ohm Meter Model : MO-2014 Your purchase of this Micro-Ohm METER marks a step forward for you into the field of p r e c i s i o n measurement. Although this Micro-Ohm
More informationREH FC-BMS3 Modbus Manual
67404 02-15 (HKT) REH FC-BMS3 Modbus Manual REH FC-BMS3 REH TA3 REH TD3 REH DT3 REH CT3 www.rehau.uk Modbus registers for REH FC-BMS3 software Version 5.0 and up Modbus SLAVE communication settings: 38.4
More informationWDD-2977C / WDD-2977VDN
WDD-2977C / WDD-2977VDN V.09I 2 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK), NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
More informationBATTERY MONITOR User Manual
BATTERY MONITOR User Manual Manual Version: BM-2016-1 TABLE OF CONTENTS 1 INTRODUCTION... 1 1.1 Product Description... 1 1.2 Key Features... 1 1.3 Versioning... 1 2 PRODUCT OVERVIEW... 2 2.1 Battery Monitor
More informationLEICA SR20 GPS RECEIVER USE AND DATA PROCESSING FOR TOPOGRAPHICAL SURVEYING IN ORDER TO REHABILITATE A COMMUNAL ROAD
LEICA SR20 GPS RECEIVER USE AND DATA PROCESSING FOR TOPOGRAPHICAL SURVEYING IN ORDER TO REHABILITATE A COMMUNAL ROAD Miluț Marius, Călina Jenica, Croitoru Alin, Buzatu Claudiu, Iosif Gheorghe University
More informationAR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features
AR-DN-RS232 An-10 / Rapid RS232 Interface Product Guide Overview The AR-DN-RS232 is a device that is used as a 2 way gateway between third party systems and the CP An-10 or Rapid lighting control systems
More informationSCM-800-PELCO. EIGHT INPUT CODE MERGER for PELCO RS-422 CAMERA CONTROL CODE.
SCM-800-PELCO EIGHT INPUT CODE MERGER for PELCO RS-422 CAMERA CONTROL CODE www.sennetech.net Sennetech, Inc. 6455 W. Bath Rd. Perry, MI 48872 U.S.A. Ph (517) 675-1150 Fax(517) 675-1151 1 SCM-800-Pelco
More informationSE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller
SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller Version 10 2 HMI Display The User HMI is configurable and allows display functions such as Date, Time, Outdoor
More informationWelcome to the KNG-P150S
Welcome to the KNG-P150S Features and Specs 512 Channels 32 Groups of 16 Channels High/Low Power 5 Watts High 2 Watts Low Multi-line Alphanumeric Display 3 year warranty Buttons and Switches Buttons and
More informationFieldMaster GS. Power/Energy Analyzer User Manual
FieldMaster GS Power/Energy Analyzer User Manual FieldMaster GS Power/Energy Analyzer User Manual Software Version 2.10 Manual Part Number 0217-378-00 EA 2002, Coherent, Inc. 1 2 FieldMaster GS Contents
More informationModbus Integration Integration for Modbus Functionality for VT8300 Series
Modbus Integration Integration for Modbus Functionality for VT8300 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS
More informationKurz Instruments Inc. 19 August 2010
BUILT-IN ZERO-MIDSPAN-SPAN DRIFT CHECK/CALIBRATOR Introduction Continuous Emissions Monitoring Systems (CEMS) have a long term stability verification requirement. Most of the equipment is verified using
More informationConfiguration Program for OZ4HZ Version 2 Tracker (rev ).
Configuration Program for OZ4HZ Version 2 Tracker (rev. 2008-12-08). The tracker is configured with a Windows program witch can be downloaded from the website. www.aargang64.dk/aprs Use a standard null-modem
More informationTT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-
-Key Features- DS Instruments Power Meter 50 to 7000MHz Frequency Counter 100 to 7000MHz R4 RF Power Meter, Signal Generator, Frequency Counter Signal Generator 300 to 9600MHz Internal 31dB Step Attenuator
More informationWRM-10 TM TRANSFORMER WINDING RESISTANCE METER
WRM-10 TM TRANSFORMER WINDING RESISTANCE METER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 June 2009 Revision
More informationOption H2, Modbus communication Automatic Gen-set Controller H SW version 2.33.X
Description of options Option H2, Modbus communication Automatic Gen-set Controller 4189340356H SW version 2.33.X Description of option Parameter list DEIF A/S Data tables Parameter table DEIF A/S, Frisenborgvej
More informationProLink Radio. 900 MHz SDI-12 Data Radio Scienterra Limited. Version A-0x0C-1-AC 20 October 2009
ProLink Radio 900 MHz SDI-12 Data Radio Scienterra Limited Version A-0x0C-1-AC 20 October 2009 For sales inquiries please contact: ENVCO Environmental Collective 31 Sandringham Rd Kingsland, Auckland 1024
More informationTECHNICAL DATASHEET #TDAX032100
Preliminary TECHNICAL DATASHEET TDAX032100 2 Bipolar Analog/Digital and 8 Universal Signal Inputs Controller CAN (SAE J1939), Ethernet Two +5V references DIN rail mount P/N: AX032100 Features: SAE J1939
More informationAPPLICATION NOTE DA-100
OZ OPTICS LTD. APPLICATION NOTE DA-100 OZ OPTICS FAMILY OF DIGITAL VARIABLE ATTENUATORS The information/data furnished in this document shall not be duplicated, used or disclosed in whole or in part for
More informationDPF-MAC Auto power factor controller
Digital Electric& Electronics System DPF-MAC Auto power factor controller MULTI POWER FACTOR AUTOMATIC MULTI POWER FACTOR AUTOMATIC Introduction DPF-MAC increases usage efficiency by controlling the power
More informationProduct Specification for model TT Transducer Tester Rev. B
TT Rev B April 20, 2010 Product Specification for model TT Transducer Tester Rev. B The Rapid Controls model TT Rev B transducer tester connects to multiple types of transducers and displays position and
More informationHL 675 Data / Impulse Transmitter set User Manual
HL 675 Data / Impulse Transmitter set User Manual Version 02/2015 TAGHeuer Timin Page 1 / 8 1. Global The Set HL 675 is ideal for transferring Timing Data and Impulses. Its 500mW emitting power and its
More informationOcean Controls KT-5221 Modbus IO Module
Ocean Controls Modbus IO Module 8 Relay Outputs 4 Opto-Isolated Inputs 2 Analog Inputs (10 bit) 1 PWM Output (10 bit) 4 Input Counters Connections via Pluggable Screw Terminals 0-5V or 0-20mA Analog Inputs,
More informationIntroduction to NFC Tester RWC5010A
Introduction to NFC Tester RWC5010A RedwoodComm Contents Overview Key Features Test Setup GUI Architecture Test Jig Automated PC Software Demo 2 Overview RWC5010A NFC Tester A test equipment to test NFC
More informationWarranty conditions are available on this website: only in English version
THE MOST ACCURATE BATTERY POWERED SYSTEM FLOWIZ ( M L 2 5 2 ) C O N V E R T E R W I T H B A T T E R Y S U P P L Y Warranty conditions are available on this website: www.isomag.eu only in English version
More informationDJ-MD5 PC Software Guidance
DJ-MD5 PC Software Guidance Ver, 1.00 2018/08/16 1 Appendix I Public... 4 1. Channel... 4 1 Frequency, call type, power... 4 2 Digital Channel Setting... 5 3 Analog Channel Setting... 6 2. Zone... 7 3.
More informationDC Instruction Manual. Professional FM Transceiver
DC-1074 Professional FM Transceiver Instruction Manual Use of the citizen band radio service is licensed in Australia by ACMA Radiocommunications (Citizen Band Radio Stations) Class Licence and in New
More informationLH Series Sensor Configurator Software User Manual rev. D 1/11/2012
LH Series Sensor Configurator Software User Manual 150307 rev. D 1/11/2012 Contents Contents LH Series Sensor Overview...3 Theory of Operation...4 Outputs...4 4-20mA Analog Output...4 RS-485 Digital Output...5
More informationFluke 125. Getting Started. Industrial ScopeMeter
Fluke 125 Industrial ScopeMeter Getting Started GB Dec 2006, Rev. 1, 09/2009 2006, 2009 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective
More informationO p e r a t i n g I n s t r u c t i o n s
O p e r a t i n g I n s t r u c t i o n s SC Standard / SC Professional SC_EN_10_02 73269 Ostring 17-19 Tel.: +49 71 53 / 30 09-0 Fax: +49 71 53 / 30 09 50 73269 Hochdorf Postfach 11 54 info@single-temp.de
More informationLava LP-4011-E P1 P2 USER MANUAL
Lava LP-4011-E P1 P2 USER MANUAL Introduction Thank you for purchasing Lava LP-4011-E. Lava LP-4011-E is a PMR-product (Private Mobile Radio) that lets you talk to as many people you wish, as often as
More informationUltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER
UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER DESCRIPTION The UltraFlo UFDD Clamp-On Ultrasonic Flow Meter is the ideal flow meter with accurate, easy-to-use, easy-to-install digital doppler technology.
More informationPam 2520 Operating Instructions For firmware version 4.0 and above
Pam 2520 Operating Instructions For firmware version 4.0 and above PAM 2520 Operating Manual June 2002 Issue 4 Page 1 of 30 Contents Contents... 2 1 Introduction... 3 2 Unpacking and Setting Up... 4 2.1
More informationModel OI-6940 Notis Quad 4-Gas Sensor Assembly
Model OI-6940 Notis Quad 4-Gas Sensor Assembly Operation Manual Revision 2.3w Product Overview The Otis Instruments, Inc. Gen II WireFree OI-6940 Notis Quad is a battery-powered explosion-proof 4-gas sensor
More informationB & D Enterprises 1P repeater controller pg 1 INTRODUCTION:
B & D Enterprises 1P repeater controller pg 1 INTRODUCTION: The 1P is a basic repeater controller. The controller uses low power devices and stores all commands and system status in non-volatile EE prom.
More informationFLOWIZ ( M L ) Warranty conditions are available on this website: only in English version
THE MOST ACCURATE BATTERY POWERED SYSTEM FLOWIZ ( M L 2 5 5 ) E l e c t r o m a g n e t i c c o n v e r t e r p o w e r e d b y b a t t e r i e s a n d u n i v e r s a l p o w e r s u p p l y. O p t i
More informationDEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description
Description of options Option H3 Serial communication Profibus DP Multi-line 2 version 2 4189340279I SW 2.42.X Description of option Functional description DEIF A/S Parameter table Data tables DEIF A/S,
More informationPIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics
Product Description Easy to use With the PIECAL 211 you can check & calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for simple hookups. Take
More informationReference for UV-5R Menus by Jim Unroe - KC9HI 2-April-2014
Long Name / Description / / Notes / 0 SQL Carrier Squelch Mutes the speaker of the transceiver in the absence of a strong signal. VHF squelch is either OFF or ON. UHF squelch is either OFF or one of 9
More informationDSC 3000 CONTROLLER-RECEIVER FOR VHF DSC TECHNICAL MANUAL
DSC 3000 CONTROLLER-RECEIVER FOR VHF DSC TECHNICAL MANUAL 700 02-96 910 000 72 ISSUE A2 Skandinavisk Teleindustri SKANTI A/S 34, Kirke Værløsevej - DK 3500 Værløse Denmark All information contained in
More informationSuperSlot Technical Specification Revision 1.0 March 20, 2015
SuperSlot Technical Specification Revision 1.0 March 20, 2015 SuperSlot and the SuperSlot logo are trademarks of Sound Devices, LLC This document is protected under Sound Devices, LLC non-disclosure agreement.
More informationProgramming Instructions for: Kenwood TK-780, 880, 980, 981 (Version 2) W/ KCT-19 Option Connector For use with: Pyramid Communications Model
Programming Instructions for: Kenwood TK-780, 880, 980, 981 (Version 2) W/ KCT-19 Option Connector For use with: Pyramid Communications Model 2012/2016/Merlin Revision E November 25, 2002 1 Introduction...3
More informationLogosol AC/DC Intelligent Servo Drive for Coordinated Control LS-174WP
Features Motors supported: - Panasonic A and S series - Brushless 60/120 commutated - Brush-commutated (DC) motors Up to 20A peak, 12A continuous output current 12 to 90VDC power supply Separate motor
More informationPIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics
Product Description Easy to use With the PIECAL 311 you can check & calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for simple hookups. Take
More informationThe LEBOW 7554 Operator's Manual 7.2
The LEBOW 7554 Operator's Manual 7.2 This manual covers operating version 7.2 of the LEBOW 7554. 11 February 1999 Lebow Products Inc Lebow Products Inc 1728 Maplelawn Rd Troy, MI 48084 1 (800) 803-1164
More information5 MegaPixel Color Camera MAR V2.0 User Manual
5 MegaPixel Color Camera 2014. MAR V2.0 User Manual Safety Precautions Before using the product, please ensure that you read the safety precautions described below. Always ensure that the product is used
More informationCalibration Instruction Manual Emerson 475 Field Communicator. Manual Revision FC.2
Calibration Instruction Manual Emerson 475 Field Communicator Manual Revision FC.2 ABM 2 Wire Radar with HART ABM Sensor Technologies Inc 2013, all rights reserved. Emerson is a registered trademark of
More informationADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /
ADI-100 Interrupter Operator s Manual 526 S. Seminole Bartlesville, OK 74003 918/336-1221 www.sescocp.com ADI - 100 Interrupter FEATURES Clock Accuracy 100% during GPS lock Clock Drift 30 µsec per degree
More informationVersion-E Manual
Version-E180220 Manual Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about installation,
More informationFluke 123/124 Industrial ScopeMeter
Fluke 123/124 Industrial ScopeMeter Getting started GB Sep 2002 2002 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective companies. 1
More informationRemote Radio Control. M880 WAVE2 C Transmitter Range. M880 for Low Integrity Stop Circuit Applications
Application A competitively priced range of remote radio control systems suitable for a wide variety of applications such as industrial doors, forestry machines, recovery vehicle winches / beds, conveyor
More informationKENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents
KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter
More informationSuperSlot Technical Specification Revision August 17, 2015
SuperSlot Technical Specification Revision 1.001 August 17, 2015 SuperSlot and the SuperSlot logo are trademarks of Sound Devices, LLC This document is protected under Sound Devices, LLC non-disclosure
More informationDMC-8 (SKU#ROB )
DMC-8 (SKU#ROB-01-007) Selectable serial or parallel interface Use with Microcontroller or PC Controls 2 DC motors For 5 24 Volt Motors 8 Amps per channel Windows software included Fuse protection Dual
More informationINSTRUCTION MANUAL WIRELESS DATA COLLECTOR MODEL WDC100
INSTRUCTION MANUAL WIRELESS DATA COLLECTOR MODEL WDC100 QUALITY SYSTEM ISO:9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)
More informationUser s manual TPM-RKE Analyzer 9936 Version Daimler Chrysler
User s manual TPM-RKE Analyzer 9936 ersion 06.03 Daimler Chrysler Reference: QS-258DCA-U User guide REGULATORY STATEMENTS This device complies with Part 15 of the FCC Rules. Operation is subject to the
More information200 us/2 ms/20 ms/200 ms, TDS ( PPM ) Real time data logger, Data logger no., RS232 CONDUCTIVITY METER Model : YK-2005CD
200 us/2 ms/20 ms/200 ms, TDS ( PPM ) Real time data logger, 16000 Data logger no., RS232 CONDUCTIVITY METER Model : YK-2005CD TABLE OF CONTENTS 1. FEATURES...1 2. SPECIFICATIONS... 2 2-1 General Specifications...2
More informationGuardian and DL3282 Modem Interface Technical Service Application Note
Guardian and DL3282 Modem Interface Technical Service Application Note OVERVIEW The following document is designed to provide information for the implementation of the Guardian Wireless Modem/Analog Radio
More informationTemp / RH / CO 2 Hand-Held Meter
Temp / RH / CO 2 Hand-Held Meter PRODUCT MANUAL Item # 3440 CONTENTS Specifications 2 Battery 3 LCD Display 3 Keypad 3 Operation 4 Troubleshooting 7 Warranty 8 CE Declaration of Conformity 8 Thank you
More informationSWR TRUE Antenna Analyzer
SWR TRUE Antenna Analyzer Operators Manual Edition Notice! This publication applies to the following COMM-connect A/S products: SWR True, type 3013, SWR Analyzer Hardware release 2 Software release 3013
More informationMIT415 Insulation tester
MIT415 Insulation tester General features o 10V & 100V ESD testing o 25V, 50V, 250V & 500V additional ranges o Insulation testing up to 50Gohms (500V) o Continuity testing at 200mA or 20mA from 0.01ohms
More informationSeismograph Sales Options
Seismograph Sales Options VanguardNewYork.com Providing Seismograph Sales & Monitoring Services to the Construction Industry. Vanguard Construction Solutions provides construction monitoring services in
More informationUSERS MANUAL TR-710.
USERS MANUAL TR-710 www.jotron.com EC Declarations of Conformity, available at www.jotron.com Read this Users Manual fully to familiarise yourself with the equipments functions and facilities. Abbreviations
More informationNetwork VPE Satellite User s Guide
Network VPE Satellite User s Guide 16 to 64 stations in eight-station increments Field programmable for future upgrades Does not require EPROM(s) replacement Operates as a stand-alone controller or under
More informationTDS Ranger Survey Pro CE Version RTK Base on known Control Point. RTK Rover - Localization with Control Points.
TDS Ranger Survey Pro CE Version 2.1.8 RTK Base on known Control Point. RTK Rover - Localization with Control Points. Pre-load control Coordinates and appropriate NGS Geoid 99/96 data files into the Ranger
More informationChapter5 Camera Settings and Other Functions
Chapter5 Camera Settings and Other Functions Changing Camera Settings.. 106 Adding or Deleting a Folder... 106 Keep Settings... 108 Changing the LCD Confirmation Time... 109 Auto Power Off Setting... 110
More informationmicro2r and DX4Win setup guide
Router setup: micro2r and DX4Win setup guide Note: The specific port numbers are not important. The key is consistency - the same port number must be used for a specific function in both Router and the
More informationSeaGauge. User s Manual. Chetco Digital Instruments
SeaGauge User s Manual Chetco Digital Instruments Copyright 2005 Chetco Digital Instruments, Inc. All rights reserved. SeaGauge is a trademark of Chetco Digital Instruments, Inc. SeaSwitch is a trademark
More informationNetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00
NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www
More informationConnecting Mains Electrical Power
Tide Level Monitoring Instrumentation The following documentation details the electrical installation for the tide level monitoring instrumentation and also a summary of the logger configurations required
More information1 Digital input (24Vac or dry contact) Inputs
Fan oil Thermostat Fan oil Thermostat Features: Attractive modern look with large LD and backlight Icons driven information and 1 line of text information 2 Pipes Analog, ON/OFF or Floating 4 Pipes Analog,
More informationSUNDIAL Light Dimmer. User's Manual
Light Dimmer User's Manual 1. PRECAUTIONS Although fuses at the input and outputs of the controller protect its circuits in case of an overload or overvoltage, we recommend installing an additional protection
More informationSTRIKER Series. Owner s Manual
STRIKER Series Owner s Manual Table of Contents Introduction...1 Device Keys... 1 Contacting Garmin Product Support... 1 Selecting the Transducer Type... 1 Zooming on the STRIKER 4... 1 Panning on the
More informationPreliminary. 4-Channel RTD/4-20 ma Wireless Sensor Node SN24R420-4
Preliminary - 4 Analog Channel, Battery Powered Wireless Sensor Node - 2 RTD Inputs and 2 4-20 ma Inputs Plus 2 Switch Inputs - Supports 2- and 3-Wire 100 ohm Platinum RTDs - Switch State and Change-of-State
More informationFC-703C Wireless M-bus Module DATA SHEET
FC-703C Wireless M-bus Module DATA SHEET FRIENDCOM TECHNOLOGY DEVELOPMENT CO.,LTD Address: Comprehensive building, Wanyelong science and technology Park, Liyuan Industrial Zone, Shiyan Street, Bao'an District,
More informationCommunicative heating controller
UC100 Communicative heating controller Summary UC100 is a communicative room heating controller with one PWM output for control of a radiator or electrical heater. It can work autonomously, or in connection
More informationOriginal instructions. SIRe Advanced. Modbus communication ... 2
Original instructions SIRe Advanced Modbus communication GB... 2 SIRe Modbus This manual describes how to connect SIRe Advanced with Modbus/RTU via RS485, the technical specification of the protocol in
More informationCD4 Series with linear image sensor and electronic shutter provides accurate measurement.
3 series Series with linear image sensor and electronic shutter provides accurate measurement. Laser displacement sensor features easy setup and operation. High accuracy of.1µm resolution and ±.1% F.S.
More informationOptical laser distance sensors. Dimensioned drawing
Dimensioned drawing en 02-2012/11 50118552 50 100mm 18-30 V DC We reserve the right to make changes DS_ODSL9L100_en_50118552.fm High resolution 0.01mm Reflection-independent distance information Highly
More informationCOG (Chip-on-Glass) Liquid Crystal Display Module
NHD-C0216AZ-FN-GBW COG (Chip-on-Glass) Liquid Crystal Display Module NHD- Newhaven Display C0216- COG, 2 Lines x 16 Characters AZ- Model F- Transflective N- No Backlight G- STN- Gray B- 6:00 Optimal View
More informationZG07 CO2 Module. ZG07 series CO2 Module. User Manual
ZG07 series CO2 Module User Manual Contents 1 GENERAL DESCRIPTION... 3 2 FEATURES OF DESIGN... 3 3 SPECIFICATION... 4 PIN ASSIGNMENT OF ZG07... 5 3.1 TIMING OF SPIR... 6 3.1.1 Format of Message... 7 1
More informationOPERATIONS MANUAL DP-110 IN-DUCT DIGITAL PSYCHROMETER TABLE OF CONTENTS
DP-110 IN-DUCT DIGITAL PSYCHROMETER OPERATIONS MANUAL Humidity & Temperature Meter with Wet Bulb Temperature and Dew Point Temperature TABLE OF CONTENTS TITLE PAGE INTRODUCTION 3 FEATURES 3 SPECIFICATIONS
More informationMedidores de vibración salida RS232 Datalogger VT-8204 LUTRON manual ingles
English usermanual VT-8204 Vibration Tachometer Your purchase of this VIBRATION TACHOMETER marks a step forward for you into the field of precision measurement. Although this VIBRATION TACHOMETER is a
More informationCMPS11 - Tilt Compensated Compass Module
CMPS11 - Tilt Compensated Compass Module Introduction The CMPS11 is our 3rd generation tilt compensated compass. Employing a 3-axis magnetometer, a 3-axis gyro and a 3-axis accelerometer. A Kalman filter
More informationLC-10 Chipless TagReader v 2.0 August 2006
LC-10 Chipless TagReader v 2.0 August 2006 The LC-10 is a portable instrument that connects to the USB port of any computer. The LC-10 operates in the frequency range of 1-50 MHz, and is designed to detect
More informationStudio Broadcast System
SET UP and USE 1. REGULATORY AND COMPLIANCE STATEMENTS... 3 2. OVERVIEW 2.1 Core Performance Targets 2.2 Specifications 2.3 System Components 2.4 System Block Diagram 3. BP24 UWB BODY PACK TRANSMITTER...
More informationWARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235
WARRANTY Long Range Systems, Inc. warrants the trap release product against any defects that are due to faulty material or workmanship for a one-year period after the original date of consumer purchase.
More informationDigiKeyer and N1MM Logger+ Setup
DigiKeyer and N1MM Logger+ Setup Router setup: Note: The specific port numbers are not important. The key is consistency - the same port number must be used for a specific function in both Router and the
More informationRevision 1. March 21, ADC Operation Manual N 11 th St San Jose CA
Revision 1 March 21, 2017 ADC Operation Manual www.mountztorque.com - 1080 N 11 th St San Jose CA 95112 408.292.2214 1 Index 1. Installation 3 1.1 Required PC specification 3 1.2 Software 3 2. Operation
More informationGuide to the SRX 600 Keypad and LCD Display
Guide to the SRX 600 Keypad and LCD Display 1 of 20 UNDERSTANDING THE LCD/KEYPAD LAYOUT 2 of 20 The keypad and LCD display define the interface through which the receiver is programmed. The program is
More informationST-10 Expert. Horn Analyzer. for serial and parallel resonance Resonators. Bär. Operator Manual.
Bär Elektronik Hauptstrasse 39 CH-8594 Güttingen 0041 71 695 12 83 Horn Analyzer ST-10 Expert for serial and parallel resonance Resonators Operator Manual Version 2.5 www.baer-elektronik.ch ndice 1.0 Controls
More informationOPERATING GUIDE OPERATING GUIDE FOR IC-F5060/F6060 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS OPERATION
OPERATING GUIDE OPERATING GUIDE FOR IC-F060/F6060 SERIES BIIS 100/MDC 100 SYSTEM/ LTR /IDAS OPERATION IMPORTANT Thank you for purchasing this Icom transceiver. The BIIS 100/MDC 100 system/ltr /IDAS (Icom
More information