1 Page 1 of 9 Exercise: DSO Function Generator Exercise, Course Objective: Demonstrate the ability to capture, measure and analyze electronic waveforms using the VAS 5051B DSO Congratulations. You have successfully completed the DSO WBT The next step is to complete the DSO Function Generator Exercise. The purpose of this exercise is to give you hands on experience using the DSO based on what you learned previously. In order to complete this exercise, you need a VAS 5051B and an Elenco Electronics FG-500 1Mhz Function Generator. It is essential that you purchase the FG-500 because you will not be able to answer all of the questions in the final assessment unless you use the FG-500 to complete this exercise. The Elenco Electronics FG-500 1Mhz Function Generator can be purchased on-line from one of the following sources (you may be able to locate additional on-line sources as well): On the home page for one of the above sites, type FG-500 in the search field. There are two versions available, the FG-500 (factory assembled version) and the FG-500K (kit version) We strongly recommend that you purchase the FG-500 assembled version and not the FG-500K kit version because it requires soldering and assembly. Once you have the 5051B and the FG-500, you re ready to perform the exercise! Continue to the next page.

2 Page 2 of 9 Note: Do not try to rush through this exercise! Remember that this is a learning process. Try to see how accurately you can complete it, not how quickly. Take your time and make sure that you understand each step before proceeding. 1. To start, configure the FG-500 as follows: Make sure that the FG-500 has a good battery. Turn the Coarse Frequency knob to 10. Turn the Fine Adj. Frequency knob to the left (counter-clockwise) until it stops. Turn the Amplitude knob to the left (counter-clockwise) until it stops. Make sure that the On/Off switch is in the OFF position. It will be turned on in a later step. The Sine/Triangle switch will not be used in this exercise, so it can remain in either position. 2. Start the VAS 5051B DSO by selecting: Test Instruments Go To DSO 3. Connect the DSO to the Function Generator as follows: Connect the DSO 1 red lead to the yellow banana jack labeled Square Wave. Connect the DSO 1 black lead to the black banana jack labeled GND.

3 Page 3 of 9 4. The first waveform is a relatively slow (low frequency) signal. To properly view this waveform, Draw Mode must be used. Select the Measuring Mode button. Select the Draw Mode button. Deselect the Measuring Mode button. 5. Turn the Function Generator ON. You should see a waveform that is similar to the one at left. If the DSO screen does not look like this: Make sure that the battery in the FG- 500 is OK. Go back to the beginning of the exercise and read each step carefully. There are two things wrong with this waveform: The waveform is displaying above the top of the screen (arrow). A waveform should never display above or below the top or bottom of the screen. The individual pulses of the waveform are so compressed that they are unreadable. To remedy these problems, the DSO must be configured to display the waveform properly, which you will do in the next steps.

4 Page 4 of 9 6. To make the waveform fit the screen, the voltage division must be changed: Select Channel A. Since the waveform needs to be smaller, the voltage division must be made larger. Select the voltage division arrow until the Channel A voltage division displays 5 V/Div. Deselect Channel A. The waveform now fits the screen. 7. To make the induvidual pulses of the waveform visible, the time division must be changed: Since the pulses need to be wider, the time division must be smaller. Select the Time/Div. arrow until the time division displays 0.5 s/div. 8. Now take a few moments to experiment with how the voltage and time division buttons alter the appearance of the waveform. First change the voltage division and then the time divsion up and down while observing the changes to the waveform. When finished return them to their previous settings: 5 V/Div. 0.5 s/div.

5 Page 5 of 9 9. Notice that the height of the waveform only occupies about 25% of the screen. While this is perfectly acceptable, it may be possible to make it taller. To do this, the zero point of the waveform must be changed. Select the Channel A button. Move the slider down to the first division above the bottom of the screen as shown at left. Now press the voltage division arrow until the voltage division for Channel A displays 2 V/Div. Deselect the Channel A button. 10. The waveform is now looking good, but there still one problem: The green Channel B waveform (DSO 2) is in the middle of our waveform, which could make it hard to read. Two things can be done to remedy this: Move Channel B to the bottom of the screen (similar to how Channel A was moved previously). Turn Channel B off, which removes it entirely. 11. Let s do both. Select Channel B. To move Channel B, move the slider to the bottom of the screen as shown at left. Now the Channel B waveform doesn t interfere with the Channel A waveform. To turn Channel B off entirely, select the Channel button, then select OFF. This removes the waveform, and may be the best choice for our next step, measuring pulse width. Deselect the Channel button. Deselect the Channel B button.

6 Page 6 of 9 Pulse Width High State Leading Edge Trailing Edge 12. Before proceeding, let s review the names for the parts of a waveform. Knowing the parts of a waveform will help you perform the following steps. Please refer to the Automotive Electrical Signals Glossary for more information. Low State Period Cursor Now measure the amplitude of the high and low signal states. Select the Freeze Frame button. Select the Cursor 1 button. Tap the screen to move the cursor to approximately the middle of one of the high state pulses as shown at left. The high state amplitude can be found in the box labeled Channel A Amplitude. Write the amplitude below. Tap the screen to move the cursor to the middle of one of the low state pulses. The low state amplitude can now be found in the box labeled Channel A Amplitude. Write the amplitude below. Ignore the number in the box labeled Time. Deselect the Freeze Frame button.

7 Page 7 of 9 Cursor 1 Cursor Next, measure the pulse width of the signal. Select the Freeze Frame button. Select the Cursor 1 button. Move Cursor 1 to the left of the leading edge of one of the pulses and then use the Cursor button to move it to the right until the box labeled Channel A Amplitude starts to increase. You aren t worried so much about the amplitude other than to see where it begins to increase. This is the point where the signal turns on. Ignore the number in the box labeled Time. Go to the next step. 15. Select Cursor 2. Move Cursor 2 to the left of the trailing edge of the same pulse and then use the Cursor button to move it to the right until the voltage display labeled Amplitude Diff. A starts to decrease. Again, you aren t worried about the amplitude other than to see where it begins to drop. This is the point where the signal turns off. The box labeled Time Difference is the pulse width of the signal. Read the pulse width and write it below.

8 Page 8 of While the previous waveform had a low frequency, the next waveform has a high frequency. Start by resetting the DSO to its default values. The easiest way to do this is to exit and restart the DSO. Select Go To Select Exit Select Test Instruments and start the DSO Leave the DSO 1 leads in the same positions as the previous steps. 17. To configure the Function Generator: Turn the Coarse Frequency knob to 100K. Leave the other knobs and switches in the same positions as they were in the previous steps. Channel A Channel B 18. The DSO should look like the screen shown at left. To configure the DSO to display this waveform: First move or remove the Channel B waveform from the screen using one of the methods shown previously. Even though this is a high frequency pulsed signal all you see is a flat line for Channel A. This is because the default time and voltage settings are too slow to display the individual pulses of the waveform. You don t know how to set the time and voltage divisions. You could experiment manually, but there is an easier way. When trying to configure the DSO for an unknown signal, use the Auto Setup mode. Select the Measuring Mode button. Select the Auto Setup button. It takes a few seconds for Auto Setup to run When Auto Setup has finished, the measuring mode changes to Auto Level.

9 Page 9 of Your screen should look like the screen shown at left. Now it is time to practice the skills you learned previously. Change the voltage division to make the waveform appear as large as possible in the screen. You need to move the zero point in the waveform so that the waveform does not display above or below the top or bottom of the screen. After completing the previous step write the final voltage division of the waveform below. Change the time division to display at least 5 readable pulses (that are not compressed) on the screen. Write the time division below. Measure the high state amplitude and write it below. Measure the low state amplitude and write it below. Measure the pulse width of the waveform and write it below. 20. Turn the FG-500 OFF. Congratulations! This completes this portion of the DSO WBT. Please take the on-line assessment to get credit for the WBT. You will need the answers from this exercise to take the on-line assessment.

Introduction to Oscilloscopes Instructor s Guide

Introduction to Oscilloscopes Instructor s Guide Introduction to Oscilloscopes A collection of lab exercises to introduce you to the basic controls of a digital oscilloscope in order to make common electronic measurements. Revision 1.0 Page 1 of 25 Copyright

More information

Name EET 1131 Lab #2 Oscilloscope and Multisim

Name EET 1131 Lab #2 Oscilloscope and Multisim Name EET 1131 Lab #2 Oscilloscope and Multisim Section 1. Oscilloscope Introduction Equipment and Components Safety glasses Logic probe ETS-7000 Digital-Analog Training System Fluke 45 Digital Multimeter

More information

54645D. Mixed Signal Oscilloscope

54645D. Mixed Signal Oscilloscope 54645D Mixed Signal Oscilloscope Page 1 of 42 Instructions for the use of the 54645D Mixed Signal Oscilloscope This pamphlet is intended to give you (the student) an overview on the use of the 54645D Mixed

More information

Fluke 125. Getting Started. Industrial ScopeMeter

Fluke 125. Getting Started. Industrial ScopeMeter Fluke 125 Industrial ScopeMeter Getting Started GB Dec 2006, Rev. 1, 09/2009 2006, 2009 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective

More information

HP 16533A 1-GSa/s and HP 16534A 2-GSa/s Digitizing Oscilloscope

HP 16533A 1-GSa/s and HP 16534A 2-GSa/s Digitizing Oscilloscope User s Reference Publication Number 16534-97009 February 1999 For Safety Information, Warranties, and Regulatory Information, see the pages behind the Index Copyright Hewlett-Packard Company 1991 1999

More information

EECS 318 Electronics Lab Laboratory #2 Electronic Test Equipment

EECS 318 Electronics Lab Laboratory #2 Electronic Test Equipment EECS 318 Electronics Lab Laboratory #2 Electronic Test Equipment Objectives: The purpose of this laboratory is to acquaint you with the electronic sources and measuring equipment you will be using throughout

More information

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL UCORE ELECTRONICS www.ucore-electronics.com 2017 Contents 1. Introduction... 2 2. Turn on or turn off... 3 3. Oscilloscope Mode... 4 3.1. Display Description...

More information

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1 UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL FATIH GENÇ UCORE ELECTRONICS www.ucore-electronics.com 2017 - REV1 Contents 1. Introduction... 2 2. Turn on or turn off... 3 3. Oscilloscope Mode... 3 3.1. Display

More information

CI-22. BASIC ELECTRONIC EXPERIMENTS with computer interface. Experiments PC1-PC8. Sample Controls Display. Instruction Manual

CI-22. BASIC ELECTRONIC EXPERIMENTS with computer interface. Experiments PC1-PC8. Sample Controls Display. Instruction Manual CI-22 BASIC ELECTRONIC EXPERIMENTS with computer interface Experiments PC1-PC8 Sample Controls Display See these Oscilloscope Signals See these Spectrum Analyzer Signals Instruction Manual Elenco Electronics,

More information

LAB I. INTRODUCTION TO LAB EQUIPMENT

LAB I. INTRODUCTION TO LAB EQUIPMENT LAB I. INTRODUCTION TO LAB EQUIPMENT 1. OBJECTIVE In this lab you will learn how to properly operate the basic bench equipment used for characterizing active devices: 1. Oscilloscope (Keysight DSOX 1102A),

More information

Sonoma State University Department of Engineering Science Spring 2017

Sonoma State University Department of Engineering Science Spring 2017 EE 110 Introduction to Engineering & Laboratory Experience Saeid Rahimi, Ph.D. Lab 4 Introduction to AC Measurements (I) AC signals, Function Generators and Oscilloscopes Function Generator (AC) Battery

More information

Digital Debug With Oscilloscopes Lab Experiment

Digital Debug With Oscilloscopes Lab Experiment Digital Debug With Oscilloscopes A collection of lab exercises to introduce you to digital debugging techniques with a digital oscilloscope. Revision 1.0 Page 1 of 23 Revision 1.0 Page 2 of 23 Copyright

More information

Faculty of Engineering, Thammasat University

Faculty of Engineering, Thammasat University Faculty of Engineering, Thammasat University Experiment 6: Oscilloscope (For room 506) Objectives: 1. To familiarize you with the Oscilloscope and Function Generator User Manual: Oscilloscope 1 5 9 4 7

More information

EENG-201 Experiment # 4: Function Generator, Oscilloscope

EENG-201 Experiment # 4: Function Generator, Oscilloscope EENG-201 Experiment # 4: Function Generator, Oscilloscope I. Objectives Upon completion of this experiment, the student should be able to 1. To become familiar with the use of a function generator. 2.

More information

Agilent N2740A Education Training Kit for 1000 Series Oscilloscopes

Agilent N2740A Education Training Kit for 1000 Series Oscilloscopes Agilent N2740A Education Training Kit for 1000 Series Oscilloscopes Lab Manual A Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including

More information

Fluke 123/124 Industrial ScopeMeter

Fluke 123/124 Industrial ScopeMeter Fluke 123/124 Industrial ScopeMeter Getting started GB Sep 2002 2002 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective companies. 1

More information

SUPER-ENHANCED POLIVOKS VCA DIY KIT ASSEMBLY INSTRUCTIONS

SUPER-ENHANCED POLIVOKS VCA DIY KIT ASSEMBLY INSTRUCTIONS SUPER-ENHANCED POLIVOKS VCA DIY KIT ASSEMBLY INSTRUCTIONS IF YOU ARE READING THIS, MOST PROBABLY YOU ARE ABOUT TO BUILD ERICA SYNTHS SUPER-ENHANCED POLIVOKS VCA. The Polivoks VCA has distinctive architecture

More information

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope. The Oscilloscope Vision is the art of seeing things invisible. J. Swift (1667-1745) OBJECTIVE To learn to operate a digital oscilloscope. THEORY The oscilloscope, or scope for short, is a device for drawing

More information

Introduction to oscilloscope. and time dependent circuits

Introduction to oscilloscope. and time dependent circuits Physics 9 Intro to oscilloscope, v.1.0 p. 1 NAME: SECTION DAY/TIME: TA: LAB PARTNER: Introduction to oscilloscope and time dependent circuits Introduction In this lab, you ll learn the basics of how to

More information

Introduction to basic laboratory instruments

Introduction to basic laboratory instruments BEE 233 Laboratory-1 Introduction to basic laboratory instruments 1. Objectives To learn safety procedures in the laboratory. To learn how to use basic laboratory instruments: power supply, function generator,

More information

Lab 6 Instrument Familiarization

Lab 6 Instrument Familiarization Lab 6 Instrument Familiarization What You Need To Know: Voltages and currents in an electronic circuit as in a CD player, mobile phone or TV set vary in time. Throughout todays lab you will investigate

More information

2400AT 4 I221 I221 1A 1A T T Rev. Rev B. C

2400AT 4 I221 I221 1A 1A T T Rev. Rev B. C 4 I2211AT Rev. Rev.B I2211AT C 2400AT Contents 1. Introduction 2. Components 3. Before operation 4. Setting up your Model 2400AT 4.1 setting the year 4.2 setting date 4.3 setting time 4.4 setting day line

More information

LAB I. INTRODUCTION TO LAB EQUIPMENT

LAB I. INTRODUCTION TO LAB EQUIPMENT 1. OBJECTIVE LAB I. INTRODUCTION TO LAB EQUIPMENT In this lab you will learn how to properly operate the oscilloscope Agilent MSO6032A, the Keithley Source Measure Unit (SMU) 2430, the function generator

More information

ECE 404 e-notes...copyright 2008 by Gregory M. Wierzba. All rights reserved...fall 2008.

ECE 404 e-notes...copyright 2008 by Gregory M. Wierzba. All rights reserved...fall 2008. ECE 404L: RF ELECTRONICS LABORATORY DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING MICHIGAN STATE UNIVERSITY I. TITLE: Lab III - AM/FM Radio - AM Radio II. PURPOSE: This lab will focus on soldering

More information

Blab Gallery Uploads: How to Reduce and/or Rotate Your Photo Last edited 11/20/2016

Blab Gallery Uploads: How to Reduce and/or Rotate Your Photo Last edited 11/20/2016 Blab Gallery Uploads: How to Reduce and/or Rotate Your Photo Contents & Links QUICK LINK-JUMPS to information in this PDF document Photo Editors General Information Includes finding pre-installed editors

More information

Ph 3455 The Franck-Hertz Experiment

Ph 3455 The Franck-Hertz Experiment Ph 3455 The Franck-Hertz Experiment Required background reading Tipler, Llewellyn, section 4-5 Prelab Questions 1. In this experiment, we will be using neon rather than mercury as described in the textbook.

More information

Lab #1 Lab Introduction

Lab #1 Lab Introduction Cir cuit s 212 Lab Lab #1 Lab Introduction Special Information for this Lab s Report Because this is a one-week lab, please hand in your lab report for this lab at the beginning of next week s lab. The

More information

AgilEye Manual Version 2.0 February 28, 2007

AgilEye Manual Version 2.0 February 28, 2007 AgilEye Manual Version 2.0 February 28, 2007 1717 Louisiana NE Suite 202 Albuquerque, NM 87110 (505) 268-4742 support@agiloptics.com 2 (505) 268-4742 v. 2.0 February 07, 2007 3 Introduction AgilEye Wavefront

More information

LAB II. INTRODUCTION TO LAB EQUIPMENT

LAB II. INTRODUCTION TO LAB EQUIPMENT 1. OBJECTIVE LAB II. INTRODUCTION TO LAB EQUIPMENT In this lab you will learn how to properly operate the oscilloscope Keysight DSOX1102A, the Keithley Source Measure Unit (SMU) 2430, the function generator

More information

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 4. Alternating Current Measurement

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 4. Alternating Current Measurement PHYSICS 171 UNIVERSITY PHYSICS LAB II Experiment 4 Alternating Current Measurement Equipment: Supplies: Oscilloscope, Function Generator. Filament Transformer. A sine wave A.C. signal has three basic properties:

More information

Notes on Experiment #1

Notes on Experiment #1 Notes on Experiment #1 Bring graph paper (cm cm is best) From this week on, be sure to print a copy of each experiment and bring it with you to lab. There will not be any experiment copies available in

More information

2 Oscilloscope Familiarization

2 Oscilloscope Familiarization Lab 2 Oscilloscope Familiarization What You Need To Know: Voltages and currents in an electronic circuit as in a CD player, mobile phone or TV set vary in time. Throughout the course you will investigate

More information

CHAPTER 6. Motor Driver

CHAPTER 6. Motor Driver CHAPTER 6 Motor Driver In this lab, we will construct the circuitry that your robot uses to drive its motors. However, before testing the motor circuit we will begin by making sure that you are able to

More information

Oscilloscope Fundamentals. For Electrical Engineering and Physics Undergraduate Students

Oscilloscope Fundamentals. For Electrical Engineering and Physics Undergraduate Students Oscilloscope Fundamentals For Electrical Engineering and Physics Undergraduate Students Agenda What is an oscilloscope? Probing basics (low-frequency model) Making voltage and timing measurements Properly

More information

FUNCTION GENERATOR KIT

FUNCTION GENERATOR KIT FUNCTION GENERATOR KIT MODEL FG-500K Assembly and Instruction Manual Elenco Electronics, Inc. Copyright 2005 by Elenco Electronics, Inc. All rights reserved. Revised 2005 REV-B 753069 No part of this book

More information

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS 1 EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS The oscilloscope is the most versatile and most important tool in this lab and is probably the best tool an electrical engineer uses. This outline guides

More information

MULT SWP X1K K VERN START FREQ DURATION AMPLITUDE 0 TTL OUT RAMP

MULT SWP X1K K VERN START FREQ DURATION AMPLITUDE 0 TTL OUT RAMP Signal Generators This document is a quick reference guide to the operation of the signal generators available in the laboratories. Major functions will be covered, but some features such as their sweep

More information

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Wyko RST Plus. All users are expected to have read and understood this document.

More information

Lab 1B LabVIEW Filter Signal

Lab 1B LabVIEW Filter Signal Lab 1B LabVIEW Filter Signal Due Thursday, September 12, 2013 Submit Responses to Questions (Hardcopy) Equipment: LabVIEW Setup: Open LabVIEW Skills learned: Create a low- pass filter using LabVIEW and

More information

DXXX Series Servo Programming...9 Introduction...9 Connections HSB-9XXX Series Servo Programming...19 Introduction...19 Connections...

DXXX Series Servo Programming...9 Introduction...9 Connections HSB-9XXX Series Servo Programming...19 Introduction...19 Connections... DPC-11 Operation Manual Table of Contents Section 1 Introduction...2 Section 2 Installation...4 Software Installation...4 Driver Installastion...7 Section 3 Operation...9 D Series Servo Programming...9

More information

EE 4440 Comm Theory Lab 5 Line Codes

EE 4440 Comm Theory Lab 5 Line Codes EE 4440 Comm Theory Lab 5 Line Codes Purpose: The purpose of this lab is to investigate the properties of various line codes. Specific parameters investigated will be wave shape, bandwidth, and transparency.

More information

EE 201 Lab! Tektronix 3021B function generator

EE 201 Lab! Tektronix 3021B function generator EE 201 Lab Tektronix 3021B function generator The function generator produces a time-varying voltage signal at its output terminal. The Tektronix 3021B is capable of producing several standard waveforms

More information

Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope, and Multisim

Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope, and Multisim SCHOOL OF ENGINEERING AND APPLIED SCIENCE DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING ECE 2110: CIRCUIT THEORY LABORATORY Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope,

More information

Advanced Lab LAB 6: Signal Acquisition & Spectrum Analysis Using VirtualBench DSA Equipment: Objectives:

Advanced Lab LAB 6: Signal Acquisition & Spectrum Analysis Using VirtualBench DSA Equipment: Objectives: Advanced Lab LAB 6: Signal Acquisition & Spectrum Analysis Using VirtualBench DSA Equipment: Pentium PC with National Instruments PCI-MIO-16E-4 data-acquisition board (12-bit resolution; software-controlled

More information

Optimizing Images for Digital Projection A few of our Camera Club members have been disappointed that their digital images just don t look the same

Optimizing Images for Digital Projection A few of our Camera Club members have been disappointed that their digital images just don t look the same Optimizing Images for Digital Projection A few of our Camera Club members have been disappointed that their digital images just don t look the same when projected during a digital critique or a slide show.

More information

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization The University of Jordan Mechatronics Engineering Department Electronics Lab.(0908322) Experiment 1: Lab Equipment Familiarization Objectives To be familiar with the main blocks of the oscilloscope and

More information

CPE 310L EMBEDDED SYSTEM DESIGN LABORATORY

CPE 310L EMBEDDED SYSTEM DESIGN LABORATORY CPE 310L EMBEDDED SYSTEM DESIGN LABORATORY LABORATORY 1 LAB SAFETY & LAB EQUIPMENT USE TUTORIAL DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING UNIVERSITY OF NEVADA, LAS VEGAS GOALS: Introduce laboratory

More information

Oscilloscope Operation. Visualizing Signals and Making Measurements

Oscilloscope Operation. Visualizing Signals and Making Measurements Oscilloscope Operation Visualizing Signals and Making Measurements Set Up Oscilloscope Start with the oscilloscope off, with the input plugged into channel one. Press the power button to turn the scope

More information

DL9040/DL9140/DL9240 Series

DL9040/DL9140/DL9240 Series DL9040/DL9140/DL9240 Series Digital Oscilloscope 3rd Edition Thank you for purchasing the DL9000 (DL9040/DL9040L/DL9140/DL9140L/DL9240/DL9240L) Digital Oscilloscope. This operation guide is designed to

More information

Physics 334 Notes for Lab 2 Capacitors

Physics 334 Notes for Lab 2 Capacitors Physics 334 Notes for Lab 2 Capacitors January 19, 2009 Do the Lab Manual sections in the following order 2-1, 2-3, 2-4, 2-2, 2-5, 2-6, 2-8 (Skip 2-7 and 2-9). First, here s a review of some important

More information

Oscilloscope. 1 Introduction

Oscilloscope. 1 Introduction Oscilloscope Equipment: Capstone, BK Precision model 2120B oscilloscope, Wavetek FG3C function generator, 2-3 foot coax cable with male BNC connectors, 2 voltage sensors, 2 BNC banana female adapters,

More information

Optional extras. Varying the basic technique. Making a parchment that is other than square

Optional extras. Varying the basic technique. Making a parchment that is other than square Optional extras Varying the basic technique CTRL + Z is your friend. This is the undo button, and I use it all the time. This handy keyboard shortcut makes experimentation so much more rewarding. Varying

More information

~ Pizzeria ~ The following developer is responsible for the declaration: Astro Corp.

~ Pizzeria ~ The following developer is responsible for the declaration: Astro Corp. ~ Pizzeria ~ The following developer is responsible for the declaration: Astro Corp. 10F, No. 111-1 HSING DE RD, SANCHUNG CITY, TAIPEI COUNTY, TAIWAN Tel:+886-2-8511-0555 Fax:+886-2-8511-0556 E-mail:sales@astrocorp.com.tw

More information

Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS

Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS 2016 15 Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS Right Side Worms FRONT REMOTE CONTROL BACK Left Side Worms Channel Display Up Stop Down Channel

More information

Page 1/10 Digilent Analog Discovery (DAD) Tutorial 6-Aug-15. Figure 2: DAD pin configuration

Page 1/10 Digilent Analog Discovery (DAD) Tutorial 6-Aug-15. Figure 2: DAD pin configuration Page 1/10 Digilent Analog Discovery (DAD) Tutorial 6-Aug-15 INTRODUCTION The Diligent Analog Discovery (DAD) allows you to design and test both analog and digital circuits. It can produce, measure and

More information

DIGITAL STORAGE OSCILLOSCOPES

DIGITAL STORAGE OSCILLOSCOPES DIGITAL STORAGE OSCILLOSCOPES Electronic Measurements Lab Massimo Ortolano 2016 POLITECNICO DI TORINO c 2011 2016 Massimo Ortolano Dipartimento di Elettronica e Telecomunicazioni (DET) Politecnico di Torino

More information

S-COR. FIGURE 1 Wiring Diagram NOTE: To reset S-COR to factory settings, press and! hold < and > buttons upon power up. INSTALLATION INSTRUCTIONS

S-COR. FIGURE 1 Wiring Diagram NOTE: To reset S-COR to factory settings, press and! hold < and > buttons upon power up. INSTALLATION INSTRUCTIONS Section 1 General Description The ClearPath Spectrum Wireless System is comprised of two devices; a Coordinator () that functions in a similar role as traditional wireless system receivers, and a Transceiver

More information

Physics 323. Experiment # 1 - Oscilloscope and Breadboard

Physics 323. Experiment # 1 - Oscilloscope and Breadboard Physics 323 Experiment # 1 - Oscilloscope and Breadboard Introduction In order to familiarise yourself with the laboratory equipment, a few simple experiments are to be performed. References: XYZ s of

More information

Contents. Item. UTD1000L User Manual

Contents. Item. UTD1000L User Manual Preface Dear users: Hello! Thanks for you choosing the brand new UNI-T device. In order to use the instrument correctly, please read the manual thoroughly and especially the Safety Notes part before using

More information

Pingable Envelope Generator

Pingable Envelope Generator Pingable Envelope Generator Kit Builder's Guide for PCB v1.0.3 4mspedals.com PEG This guide is for building a Pingable Envelope Generator (PEG), which is an intermediate-level kit. You should be confident

More information

GXCapture 8.1 Instruction Manual

GXCapture 8.1 Instruction Manual GT Vision image acquisition, managing and processing software GXCapture 8.1 Instruction Manual Contents of the Instruction Manual GXC is the shortened name used for GXCapture Square brackets are used to

More information

2 : AC signals, the signal generator and the Oscilloscope

2 : AC signals, the signal generator and the Oscilloscope 2 : AC signals, the signal generator and the Oscilloscope Expected outcomes After conducting this practical, the student should be able to do the following Set up a signal generator to provide a specific

More information

LLS - Introduction to Equipment

LLS - Introduction to Equipment Published on Advanced Lab (http://experimentationlab.berkeley.edu) Home > LLS - Introduction to Equipment LLS - Introduction to Equipment All pages in this lab 1. Low Light Signal Measurements [1] 2. Introduction

More information

MFJ ENTERPRISES, INC.

MFJ ENTERPRISES, INC. Screwdriver Antenna Controller Model MFJ-1926 INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment! MFJ ENTERPRISES, INC. 300 Industrial Park Road Starkville, MS 39759 USA Tel:

More information

DPC-10. DPC-10 Software Operating Manual. Table of Contents. Section 1. Section 2. Section 3. Section 4. Section 5

DPC-10. DPC-10 Software Operating Manual. Table of Contents. Section 1. Section 2. Section 3. Section 4. Section 5 Table of Contents Section 1 Section 2 Section 3 Section 4 Section 5 About the Software Test Function Programming Functions Connections Basic Mode Connection RC Mode Connection Using the DPC-10 Test Functions

More information

Fluke 192/196/199. MS 190 and MA 190. Users Manual Supplement

Fluke 192/196/199. MS 190 and MA 190. Users Manual Supplement Fluke 192/196/199 MS 190 and MA 190 Users Manual Supplement 4822 872 00979 April 2000, Rev.2, 9/00 2000 Fluke Corporation. All rights reserved. Printed in the Netherlands. All product names are trademarks

More information

THREE-AXIS MORPHING WITH NONLINEAR WAVESHAPERS FREQUENCY +/- 8V SELECT FM/EXT IN AC 10VPP OSC A LINK FREQUENCY MODE SELECT OSC B CV +/- 8V MICRO SD

THREE-AXIS MORPHING WITH NONLINEAR WAVESHAPERS FREQUENCY +/- 8V SELECT FM/EXT IN AC 10VPP OSC A LINK FREQUENCY MODE SELECT OSC B CV +/- 8V MICRO SD PISTON HONDA DUAL WAVETABLE OSCILLATOR THREE-AXIS MORPHING WITH NONLINEAR WAVESHAPERS FREQUENCY SYN C 0-5V MODE SELECT CV +/- 8V PRESET/EDIT 1V/OCT 0-8V CV +/- 8V FM/EXT IN AC 10VPP OSC A LINK FREQUENCY

More information

Oscilloscope Measurements

Oscilloscope Measurements PC1143 Physics III Oscilloscope Measurements 1 Purpose Investigate the fundamental principles and practical operation of the oscilloscope using signals from a signal generator. Measure sine and other waveform

More information

TOP SERVO SIGNAL 5 SERVO SIGNAL 3 SERVO SIGNAL 4 SERVO SIGNAL 6 T B T B T B T B T B SERVO TRIGGER 1 BOTTOM

TOP SERVO SIGNAL 5 SERVO SIGNAL 3 SERVO SIGNAL 4 SERVO SIGNAL 6 T B T B T B T B T B SERVO TRIGGER 1 BOTTOM Micro Miniatures Servo Controller Channel Location of connections and switches TOP SERVO SIGNAL SERVO SIGNAL 7 SERVO SIGNAL 6 SERVO SIGNAL 5 SERVO SIGNAL SERVO SIGNAL SERVO SIGNAL SERVO SIGNAL SIGNAL COMMON

More information

7.0 - MAKING A PEN FIXTURE FOR ENGRAVING PENS

7.0 - MAKING A PEN FIXTURE FOR ENGRAVING PENS 7.0 - MAKING A PEN FIXTURE FOR ENGRAVING PENS Material required: Acrylic, 9 by 9 by ¼ Difficulty Level: Advanced Engraving wood (or painted metal) pens is a task particularly well suited for laser engraving.

More information

Measurement Bench. Accessories. Power supply. Wave form generator. Multimetre. Oscilloscope. Dr. L.Scucchia

Measurement Bench. Accessories. Power supply. Wave form generator. Multimetre. Oscilloscope. Dr. L.Scucchia Measurement Bench Accessories Power supply Wave form generator Multimetre Oscilloscope OSCILLOSCOPE Oscilloscope (1) The oscilloscope allows to display a voltage (vertical axis - Y axis) versus time (horizontal

More information

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial 1 This is a programmed learning instruction manual. It is written for the Agilent DSO3202A Digital Storage Oscilloscope. The prerequisite

More information

04. Two Player Pong. 04.Two Player Pong

04. Two Player Pong. 04.Two Player Pong 04.Two Player Pong One of the most basic and classic computer games of all time is Pong. Originally released by Atari in 1972 it was a commercial hit and it is also the perfect game for anyone starting

More information

Now we re going to put all that knowledge to the test and apply your cyber skills in a wireless environment.

Now we re going to put all that knowledge to the test and apply your cyber skills in a wireless environment. We are devoting a good portion of this course to learning about wireless communications systems and the associated considerations, from modulation to gain to antennas and signal propagation. Why? Because

More information

audionet amp II G2 Owner's Manual Mono - Amplifier

audionet amp II G2 Owner's Manual Mono - Amplifier audionet amp II G2 Mono - Amplifier Owner's Manual Owner's manual The Audionet-Team would like to congratulate you to purchasing the Audionet AMP II G2! Your Audionet AMP II G2 is designed for absolutely

More information

ZOOMAX Butterfly. Handheld Video Magnifier. User s Guide. Version 3.2

ZOOMAX Butterfly. Handheld Video Magnifier. User s Guide. Version 3.2 ZOOMAX Butterfly Handheld Video Magnifier User s Guide Version 3.2 ZOOMAX Technology Co., Limited 9F, Building D, Paradise Software Park, No.3 Xidoumen Road, Xihu District, Hangzhou, China 310012 Copyright

More information

Agilent 33522A Function Arbitrary Waveform Generator. Tektronix TDS 3012B Oscilloscope

Agilent 33522A Function Arbitrary Waveform Generator. Tektronix TDS 3012B Oscilloscope Agilent 33522A Function/Arbitrary Waveform Generator and Tektronix TDS 3012B Oscilloscope Agilent 33522A Function Arbitrary Waveform Generator The signal source for this lab is the Agilent 33522A Function

More information

PIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions

PIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions PIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions Easy to use With the Model 541 you can check & calibrate all your frequency instruments and measure flow sensors. Take it into

More information

UNIVERSITY OF CALIFORNIA, SANTA BARBARA Department of Electrical and Computer Engineering. ECE 2A & 2B Laboratory Equipment Information

UNIVERSITY OF CALIFORNIA, SANTA BARBARA Department of Electrical and Computer Engineering. ECE 2A & 2B Laboratory Equipment Information UNIVERSITY OF CALIFORNIA, SANTA BARBARA Department of Electrical and Computer Engineering ECE 2A & 2B Laboratory Equipment Information Table of Contents Digital Multi-Meter (DMM)... 1 Features... 1 Using

More information

DIGITAL STORAGE OSCILLOSCOPES

DIGITAL STORAGE OSCILLOSCOPES 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com DIGITAL STORAGE OSCILLOSCOPES Digital Storage Oscilloscope 100MS/s Acquisition (40MS/s 2 Acquisition) 100MHz 2 channel. OUTLINE

More information

How to Test OnFILTER Ground EMI Filters

How to Test OnFILTER Ground EMI Filters How to Test OnFILTER Ground EMI Filters Scope Ground EMI filters reduce high-frequency current in ground while preserving other grounding properties and meeting safety requirements This document outlines

More information

Mic Mate Pro. User Manual

Mic Mate Pro. User Manual R Mic Mate Pro User Manual Mic Mate Pro Features Congratulations and thank you for purchasing the MXL Mic Mate Pro. This device is designed to minimize your setup for recording and allow for professional

More information

DSO1000 Oscilloscope Educator s Training Resources. Lab Guide and Tutorial for Undergraduate Electrical Engineering and Physics Students

DSO1000 Oscilloscope Educator s Training Resources. Lab Guide and Tutorial for Undergraduate Electrical Engineering and Physics Students DSO1000 Oscilloscope Educator s Training Resources Lab Guide and Tutorial for Undergraduate Electrical Engineering and Physics Students s1 Notices Agilent Technologies, Inc. 2008-2012 The copyright on

More information

How to prepare your files for competition using

How to prepare your files for competition using How to prepare your files for competition using Many thanks to Margaret Carter Baumgartner for the use of her portrait painting in this demonstration. 2015 Christine Ivers Before you do anything! MAKE

More information

Introduction to Lab Instruments

Introduction to Lab Instruments ECE316, Experiment 00, 2017 Communications Lab, University of Toronto Introduction to Lab Instruments Bruno Korst - bkf@comm.utoronto.ca Abstract This experiment will review the use of three lab instruments

More information

Exercise 2-1. PAM Signals EXERCISE OBJECTIVE DISCUSSION OUTLINE. Signal sampling DISCUSSION

Exercise 2-1. PAM Signals EXERCISE OBJECTIVE DISCUSSION OUTLINE. Signal sampling DISCUSSION Exercise 2-1 PAM Signals EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the generation of both natural and flat-top sampled PAM signals. You will verify how the frequency

More information

STEADY HAND GAME WITH LATCHING LED

STEADY HAND GAME WITH LATCHING LED ESSENTIAL INFORMATION BUILD INSTRUCTIONS CHECKING YOUR PCB & FAULT-FINDING MECHANICAL DETAILS HOW THE KIT WORKS TEST YOUR HAND-EYE COORDINATION WITH THIS STEADY HAND GAME WITH LATCHING LED Version 2.0

More information

/ Digital Oscilloscope

/ Digital Oscilloscope / Digital Oscilloscope 1st Edition Foreword Thank you for purchasing the YOKOGAWA DL1540C/1540CL Digital Oscilloscope. This operation guide explains the basic operations of the digital oscilloscope focusing

More information

Wixey ELECTRONIC DIGITAL READOUT

Wixey ELECTRONIC DIGITAL READOUT Wixey ELECTRONIC DIGITAL READOUT Model WR500 INSTRUCTIONS Step 1- Mounting the readout assembly to your planer 1 Tighten any of the side cover mounting screws (1) and if necessary use a small amount of

More information

LAB 2 Circuit Tools and Voltage Waveforms

LAB 2 Circuit Tools and Voltage Waveforms LAB 2 Circuit Tools and Voltage Waveforms OBJECTIVES 1. Become familiar with a DC power supply and setting the output voltage. 2. Learn how to measure voltages & currents using a Digital Multimeter. 3.

More information

ARS AUGMENTED REALITY SERIES

ARS AUGMENTED REALITY SERIES REQUIRED HARDWARE This tutorial focuses on installing and calibrating the software, but doesn t cover the details of the hardware setup. (Note: Do not plug the Kinect or projector unit until instructed

More information

Axioscan - Startup. 1. Turn on the Axioscan (button to the left) and turn on the computer. 2. Log on and start the ZEN Blue software from the desktop

Axioscan - Startup. 1. Turn on the Axioscan (button to the left) and turn on the computer. 2. Log on and start the ZEN Blue software from the desktop Axioscan - Startup 1. Turn on the Axioscan (button to the left) and turn on the computer 2. Log on and start the ZEN Blue software from the desktop 3. Press ZEN slidescan and Start System 4. Start by changing

More information

Laboratory 1 Generating and viewing signals rev. 20e. Oscilloscope Settings

Laboratory 1 Generating and viewing signals rev. 20e. Oscilloscope Settings 1 2 Laboratory 1 Generating and viewing signals rev. 20e Purpose: Familiarization with the basic functions of an oscilloscope and of a signal generator. Adjusting and measuring specific parameters of signals.

More information

Installation And Programming Instructions For Profile Series With RF Technology

Installation And Programming Instructions For Profile Series With RF Technology Installation And Programming Instructions For Profile Series With RF Technology A7691A www.sargentlock.com 1 Table of Contents General Description Page 2 3 4 5 6 7 Installation of RF Technology Lock...1

More information

Bluetooth Audio Streaming Installation Guide for Becker Radios with AUX feature

Bluetooth Audio Streaming Installation Guide for Becker Radios with AUX feature Courtesy of:discountcarstereo.com Picture for illustration purposes only Bluetooth Audio Streaming Installation Guide for Becker Radios with AUX feature Revised: June 12, 2015 Introduction: Thanks to the

More information

Experiment P50: Transistor Lab 3 Common-Emitter Amplifier (Power Amplifier, Voltage Sensor)

Experiment P50: Transistor Lab 3 Common-Emitter Amplifier (Power Amplifier, Voltage Sensor) PASCO scientific Vol. 2 Physics Lab Manual: P50-1 Experiment P50: Transistor Lab 3 Common-Emitter Amplifier (Power Amplifier, Voltage Sensor) Concept Time SW Interface Macintosh file Windows file semiconductors

More information

The Perception. Is Reality. Test Bench

The Perception. Is Reality. Test Bench Test Bench The Perception Y ou would be hard-pressed to find an automotive technician who has not used an oscilloscope to diagnose a particular problem. Most technicians either own a scope or are planning

More information

Making sense of electrical signals

Making sense of electrical signals Making sense of electrical signals Our thanks to Fluke for allowing us to reprint the following. vertical (Y) access represents the voltage measurement and the horizontal (X) axis represents time. Most

More information

Week 7: Design a Logarithmic Voltmeter. A variation on Experiment 19 Validation by 8pm on October 14

Week 7: Design a Logarithmic Voltmeter. A variation on Experiment 19 Validation by 8pm on October 14 Week 7: Design a Logarithmic Voltmeter A variation on Experiment 19 Validation by 8pm on October 14 Op Amps Will not work if V+ and V- are not connected to +9V and -9V, respectively. Will get extremely

More information

How to blur a background in Photoshop CS3, Elements 9 or later By Steve Zimic

How to blur a background in Photoshop CS3, Elements 9 or later By Steve Zimic This is a technique I developed which allows blurring of the background without any bleeding of the main subject into the background. This technique does require a working knowledge of the various selection

More information