New Single Straight Tube Type OVAL Coriolis Mass Flowmeter. MK Transmitter : ST9101, ST9801. See general performance table (page 2).

Size: px
Start display at page:

Download "New Single Straight Tube Type OVAL Coriolis Mass Flowmeter. MK Transmitter : ST9101, ST9801. See general performance table (page 2)."

Transcription

1 New Single Straight Tube Type OVAL Coriolis Mass Flowmeter ST MK : ST90, ST980 GENERAL SPECIFICATION GS.No.GBN034-4-E GENERAL The STmass MKII is a user friendly coriolis mass flowmeter capable of making direct mass flowrate measurement with a single straight tube. Combined with our sensor technologies and most advanced electronics techniques accumulated over many years, this perfect full-moon shaped mass flowmeter finds a wide range of applications with a high degree of metering accuracy. FEATURES. The sensor body has a welded one-piece construction made of stainless steel or Hastelloy C in a single straight tube design. 2. The transmitter comes either in a highly sophisticated type, integrally mounted with or separately mounted from the sensor, ST980, and a smallest-in-the-world type, ST Has no pocket for the process fluid to stand - most desirable from an ease-of-cleaning point of view. 4. Process connections may be so finished as to comply with sanitary requirements. 5. The display in the transmitter shows variables, such as the flowrate, density, and temperature, with a touch of a GENERAL SPECIFICATIONS Sensor Unit Item Model Nominal size Wetted Materials Housing Process connection Applicable fluid Temp. Non-explosionproof type Range Explosionproof type ensity measuring range Max. Operating pressure Sensor housing withstands Flow direction Explosionproof construction ST980 ST90 ST980 mode select button(or with a mode select magnet)on the panel. 6. Compact design reduces space requirements for pipelines. 7. Absence of moving parts justifies its use for long life and ease of handling. 8. Communication interface is a standard feature. 9. Explosion-proof construction permits installation in hazardous locations. 0. Certified as a high pressure gas vessel. (The flow tube is made of SUS36L.) escription S00C S05C S025C S040C S050C S080C 5mm or /2 5mm or /2 25mm or 40mm or /2 50mm or 2 80mm or 3 SUS36L or SUS36L+Hastelloy C (S05, S025 only) SUS304 JIS 0, 20K RF, ANSI/JPI 50 RF, IF ferrule Liquid 25~+30 C (For liquid Temp. above 20 C, the transmitter should be of separate type). 20~+30 C 0.5 ~.0g/mL, 0.7 ~.3g/mL,.0 ~.5g/mL Up to 2.45MPa,epends on the process connection pressure rating (see page 2). 2.8MPa Normal or reverse (ST90; normal only) See the transmitter specifications below. Item escription Model ST980(sophisticated model) ST90(compact design) Rangeability Flowrate See general performance table (page 2). Temperature 25~+30 C ( 20~+30 C in the ex. model) Power supply Power consumption Ambient temperature Transmission length (separate type) Explosionproof construction ust and waterproof construction Mounting 85~264VAC 50/60Hz or 20~30VC Max. 25VA 20~+50 C Max. 5 m (exclusive cable used) Combined explosionproof [Exd (ib) II BT3] IP65 Integrally or separately mounted 20~30VC Max. 6VA 20~+55 C Combined explosionproof [Exd (ib) II BT3] IP65 or equiv. Integrally mounted isplay Mass Communication interface Status input 8-digit (7-segment) LC display 4.6kg approx.(5.8kg approx., separate type) HART protocol and Bell 202 Remote zero or optional feature/contact-closure input (From a contact).6kg approx. None Pulse output Analog output Select one from, 2, 3 and 4 below: Voltage pulse 0 :.5V max., : 5V Output impedance 2.2kΩ or open collecter output (0V min.~30vmax.,50ma C),FS:0.~0000Hz Current pulse output (4/20mA) 0 : 4mA, : 20mA 2 Voltage plise output 0 : V max., : 5V 4~20mAC (max. load 600Ω) Two outputs from mass flow, 3 Open collector pulse output 30V, 50mA C max. 4 Analog output (4/20mA) Mass/temp. or temperature. Additional damping:0~200sec. Either or 4 for communications. In frequency output FS: 0.~000Hz Status output rive control voltage output Open collector output (Normal : ON; Abnormal: OFF) Select one from Error, Flow direction, Hi/Lo alam C voltage output (for checking) None None ~ 3 pulse output : Mass OVAL Corporation Head Office: Tokyo; Tel Fax Beijing Office: Tel., Fax Tel Overseas Branch Offices: Seoul, Singapore, Taipei

2 GENERAL PERFORMANCE Item escription Model S00C S05C S025C S040C S050C S080C Normal flow range (kg/min) 0~2 0~40 0~20 0~300 0~600 0~200 Allowable flow range (kg/min) 0~8 0~60 0~80 0~450 0~900 0~800 Min. range (kg/min) 0~.2 0~ 4 0~ 2 0~ 30 0~ 60 0~ 20 Flow rate Accuracy in factory calibration [±0.2% ± zero stability error] of R Repeatability [±0.%±/2 zero stability error] of R Zero stability 0.05% of max flow rate at normal flow range ensity Measuring range 0.5 ~.0g/mL, 0.7 ~.3g/mL,.0 ~.5g/mL (Liquids) Accuracy in factory calibration(option) ±0.004g/mL S00 without density function Analog accuracy ST980 Accuracy at the flow rate ±0.% of FS ST90 Accuracy at the flow rate ±0.3% of FS ISPLAY ST980 : Instantaneous mass flow rate 2: ensity 3: Temperature 4: Totalized flow (mass) 5: Analog out put (Indicate with % of full scale valve) 6: Analog out put 2 (Indicate with % of full scale valve) isplay unit isplay modes are selectable with a sensor of infrared rays behind the display window. ST90 METER ERROR Totalized flow 2 Instantaneous flow rate 3 % Instantaneous flow rate 4 ensity (optional) 5 Temperature Hold the mode selector magnet over this area to Mode select switch area change display modes. Meter Error(%) Guaranteed accuracy range at mass flow (including zero stability error) Actual Meter Error Flow rate % (Normal flow range) 2

3 PRESSURE LOSS S00C 0 S040C p Factor : C p Factor : C Flow rate (kg /min) Flow rate (kg /min) S05C p Factor : C Flow rate (kg /min) S050C p Factor : C Flow rate (kg /min) S025C S080C p Factor : C p Factor : C mpa s Flow rate (kg /min) Flow rate (kg /min) NOTE: Curves for Models S00C through S050C show pressure losses relative to viscosities (from top to bottom) 500, 200, 00, 50, 0, (mpa s). [except S080C Model] How to determine pressure loss. Find the pressure loss factor C from flow rate (kg/min) and viscosity (mpa s) of parameter. ividing the obtained value C by specific gravity d ( for water) gives the pressure loss. That is, P= C (MPa) d 2. For high viscosity liquids not shown in these graphs, Calculate the pressure loss by the following formula: µ2 P2=CX X µ d where P2 : Pressure loss of high viscosity liquid (MPa) µ2 : Viscosity of high-viscosity liquid (mpa s) d: Specific gravity of high-viscosity liquid ( for water) µ : Max. viscosity shown in the graph (mpa s) C : Pressure loss factor found from the max. viscosity curve at a given flow rate. 3

4 ST ST IMENSIONS [Unit in mm] Integrate Type Flange connection Ferrule connection 50 C H Conduit connection G /2 H C F E L Type JIS 0 K ANSI 50 L ø L ø H C øf øg E Mass(kg) S00C S05C S025C S040C S050C S080C Type Nom. Size L H C ø E Mass(kg) S00C 5A S05C 5A S025C /2S S040C 2S S050C 2 /2S S080C Nominal size : A :mm, S :Inch Sanitary version Under preparation Separate Type Flange connection Ferrule connection H C E L Conduit connection G3/4 Terminal box C H F G E L E L JIS 0 K ANSI 50 Type L ø L ø H C øf øg E Mass(kg) S00C S05C S025C S040C S050C S080C Type Nom. Size L H C ø E Mass(kg) S00C 5A S05C 5A S025C /2S S040C 2S S050C 2 /2S S080C Nominal size : A :mm, S :Inch Sanitary version Under preparation Local Mount Type (ST980) <Stand on Type> ST 3 23 U bolt X2(for 2" SGP) Conduit connection(g /2) Non Intrinsically safe side Conduit connection(g /2) Intrinsically safe side 56 4

5 ST ST MK IMENSIONS [Unit in mm] Small size transmitter integrate Type (ST90) NOTE : For non-explosionproof models, pressuretight packing assembly is not furnished. Flange connection isplay switching magnet Flange connection C H Type JIS 0 K ANSI 50 H C øf øg E Mass(kg) L ø L ø S00C F G E L S05C S025C S040C S050C S080C Ferrule connection Ferrule connection Type Nom. size L H C ø E Mass(kg) S00C 5A S05C 5A H C S025C /2S S040C 2S E S050C 2 /2S S080C Nominal size : A :mm, S :Inch Sanitary version Under preparation L REMOTE MEASURING SYSTEM Integrate Type (ST980) MT9603 (Preparation) Sensor Unit Flow rate, Temp., ensity, Analog Output Totalizer EL022 4~20mAC Separate Type ST980 Flowrate Frequency Output Voltage or open collector Totalizer EL023 Batch controller EL80, 870 Sensor Unit Personal Computer Smart Communication Unit EL CS, Computer etc Integrate Type Small size transmitter ST90 Flow indicator EL23 Recorder Hazardous area Non hazardous area Controllers In case of separate type, the sensor unit and transmitter are connected with exclusive cable 2 EL2300: Smart Communication Unit. See General Specification sheet No.GEL02-E. 5

6 WIRING for ST980 Integrate Type A Power Terminal View A External Earth Terminal Power Terminal Enternal Earth Terminal TERMINAL BOAR LINE/+ GN NEUT/ Earth ground either at external G or internal G terminal. EARTH I. S. earth ground terminal (Class A GN terminal) Terminal E must be grounded without fail Terminal for Output Signals Remote Output Signal Connection Terminals Item Terminal No. Label escription Remarks Output Signal Power PULSE + 2 PULSE Pulse output 3 S OUT + Open collector output 4 S OUT Normal: ON; Abnormal: OFF 5 S IN Remote zero input (Form a contact input) 6 S IN COM 7 ANALOG2+ Analog output 2 8 ANALOG2 9 ANALOG+ 0 ANALOG Analog output. GAIN + rive gain output (test output) 2. GAIN Common LINE/+ Power GN Earth ground NEUT/ Power EARTH Class A earth ground work. Use shielded twisted pairs AWG24-6 for output wiring. 2. Max. load resistance is 600Ω for analog output and Frequency output (voltage pulse) transmission length is Max. 0m (at 0kHz) Max. 20m (at 5kHz) Max. 00m (at khz) Max. km (at 00Hz). in C power LINE : + NEUT: 2. Terminal G must be grounded. Terminals to Sensor Category Cable color Subject escription Remarks Sensor to Black SHIEL Bundle BWN/RE, GRN/WHT, BLU/GRY, ORG/PUR/YEL shield wires. Brown (+)RIVE Red ( )RIVE Flow tube drive output Orange (+)TEMP A' Temp. Input (Outer side) Yellow (+)TEMP Temp. Input Green (+)LPO Left position pickoff input Blue (+)RPO Right position pickoff input Purple (+)TEMP Temp. Input (Inner side) Gray ( )RPO Right position pickoff input White ( )LPO Left position pickoff input Use 9-conductor Interconnect cable. Transmission length : Max. 5m 6

7 ST Separate Type (ST980) Terminal Box Exclusive Cable Sensor Terminal Box Separation cover to be applied in a hazardous area Shield wires (Brown/Red) Clip here except for shield wires covering BWN and RE wires. Exclusive cable (Max. 5m) Shield (Protected by black tube) Brown Red Brown Red Separation cover to be applied in a hazardous area (Sensor Terminal Box) Green White Cut Blue Gray Cut Purple Yellow Orange Cut Green White Blue Gray Purple Yellow Orange Shield wires (BWN/RE, GRN/WHY, BLU/GRY, PUR/YEL/ORG) Shield (Protected by black tube) ( Terminal Box) (ST980) NOTE. o not fail to use exclusive cable. 2. Shield wire preparation () end: Bundle the shield wires corresponding with brown/red, green/white, blue/grey, purple/yellow/orange and slip a black sleeve over them as shown in the figure, exercising care to avoid potential contact with the housing and other conductive parts. (2) Sensor end: Slip a black sleeve over the shield wires corresponding with brown/red pair cable as shown in the figure, exercising care to avoid potential contact with the housing and other conductive parts. Clip all other shield wires. How to install the cover. After wiring with the relay terminals, install the cover as shown below. Fix Exclusive cable Separation Cover 7

8 WIRING for ST90 Connecting terminals and Output signals. Terminal No. isplay escription + Power supply 20~30VC Power terminal (20~30VC) Pulse/analog Output terminal (Analog or Pulse output) 4 Intrinsically safe GN Intrinsic safety earth terminal ("Class A" GN work). Analog or Current pulse output Setting of OUT switch in Main unit. (Note : Set in factory on spec.) : ON, 2 : OFF, 3 : OFF, 4 : OFF Terminal base 2 +20~30VC 0V Power ST90 I.S. EX. GN Terminal 3 Load resistancerl 4 4~20mA Analog or 4/20mA Current pulse External GN terminal Class GN Class A GN 2. Voltage pulse output Setting of OUT switch in Main unit. (Note : Set in factory on spec.) : OFF, 2 : ON, 3 : OFF, 4 : ON ST90 Terminal base I.S. EX. GN Terminal External GN terminal 2 +20~30VC Voltage pulse output H : 5V L : 0V Short of 2, 4 makes up 3 wires system (SUP, SIG, COM) H No. 3 of the OUT switch shorts, Class A GN 2 and 4 Internally. In case of OFF, (2) and (4) Class GN are isolated each other. 0V Power 3. Open collector pulse output Setting of OUT switch in Main unit. (Note : Set in factory on spec.) : OFF, 2 : ON, 3 : OFF, 4 : OFF ST90 Terminal base I.S. EX. GN Terminal External GN terminal Class GN + Class A GN +20~30VC 0V Open collector pulse output Max. imposing : 30V, 50mAC Power Short of 2, 4 makes up 3 wires system (SUP, SIG, COM) H No. 3 of the OUT switch shorts, 2 and 4 Internally. In case of OFF, (2) and (4) are isolated each other. 8

9 STANAR INSTALLATION. Typical Installation (See figure at right.) ) Avoid pipeline stresses on the STmass MKII. 2) A The STmass MKII should be supported near and between connections to the process pipelines. 3) Avoid supporting the STmass MKII body directly. 4) Pipeline should be arranged such that the STmass MKII is constantly filled with the process fluid. Avoid, however, to install it in a pocket where slurries may build up. 5) Provide a valve downstream of the meter to allow zeroing by obtaining a true zero flow. We recommend to provide another valve upstream of the meter for servicing or maintenance. Valve Flow Valve 2. Precautions at Installation ) Locate the STmass MKII at least one meter from large transformers, motors, or other sources of electromagnetic induction. Also avoid installation near the sources of excessive vibration, such as motors and pumps. 2) If it is desired to make a measurement of a process fluid requiring heat retention, heat trace may be applied directly to the sensor body. Heat trace should be held below 30 C. Explosionproof models require the temperature to be held below their maximum allowable levels. 3) The sensor unit is of gastight construction. To prevent dew condensation inside in a low temperature application, it is filled with argon gas. For this reason, avoid dropping or giving it impact shocks. 4) In a horizontal run, install the sensor unit with the transmitter up as shown in the figure. 5) A control valve should be located downstream of the STmass MKII. In an arrangement where cavitation may possibly take place, locate it at least 5 meters away. 3. Physical Orientation The sensor unit may be installed either in a horizontal or a vertical line. Installation in a vertical run facilitates fast process fluid replacement and self draining: you can make the most of the desirable characteristics of the single straight-tube STmass MKII. No. 2 Horizontal Piping Vertical Piping Installation Position o not forget to specify the physical orientation when you order. 9

10 PROUCT COE EXPLANATION Sensor Unit Code No. Item escription Model S STmass MK II 0 0 5mm 0 5 5mm Nom. size mm mm mm mm Construction C Local installation S S SUS36L Material S H SUS36L+Hastelloy-C (S05, S025 Only) 3 Flange connection Connection type 4 Ferrule connection JIS 2 ANSI Connection standard 3 JPI 4 IF ferrule 0 Ferrule (5K) Pressure rating 0K 2 20K, 50Lb 2 0.5~.0 g/ml ensity range 3 0.7~.3 g/ml 4.0~.5 g/ml K Integrate type ST980(Temperature range Max.20 C) Installation mode of transmitter R Separate type ST980(Rack mount type MT9603(Preparation)) S small size transmitter Integrate type(st90) Local mount (ST980) Code No. Item escription Model S T Local mount transmitter K Integrate type Type of Construction R Separate type 6 20~30 VC Power supply 7 85~264 VAC 50/60Hz M Mass flow + ensity M T Mass flow + Temperature Analog output T ensity + Temperature M X Mass flow rate Output (voltage pulse output) X ensity Output (voltage pulse output) Mass flow voltage pulse (Option) Frequency output 3 Mass flow open collector pulse 0 Nonexplosionproof TIIS (domestic explosionproof) Explosionproof 2 ATEX (available in near future) 7 NEPSI (china explosionproof) Local mount small size transmitter (ST90) Item Code No. escription Model S T 9 0 S Small size transmitter (Integrate type) Power supply 6 20~30VC isplay LC display provided M 0 0 Mass flow rate analog output 0 0 ensity analog output Output T 0 0 Temperature analog output 0 M Mass flow rate voltage pulse output 0 M 2 Mass flow rate open collector pulse 0 M 3 Mass flow rate current pulse output Selection of pulse output Selection of Analog output NOTE: function is not provided in case of voltage and open collector. 0

11 PLEASE SUPPLY THE FOLLOWING INFORMATION WHEN YOU INQUIRE.. Process fluid 2. Flow range 3. Fluid temperature 4. Operating pressure 5. Ambient temperature 6. Fluid flow direction 7. Nominal size 8. Required accuracy 9. Process connection 0. Explosion-proof. Power supply 2. Output specifications 3.Companion receiver 4. Transmission length 5. Exclusive cable length 6. In case of a separated type transmitter Name Sp.gr. Viscosity Slurry content in a slug flow % Max. Normal Full scale kg/min kg/h Max. C Normal C Min. C Max. MPa Normal MPa Min. MPa Max. C Min. C Left Right Right Left Bottom Top ( Top Bottom) mm inch ± % of reading ± % of full scale Flanged connection(flange rating) Ferrule connection Required Not required Power V AC C (ST90: C only) Volt. pulse : [0] :.5V [] : 5VC min. Out. impedance : 2.2kΩ Frequency output Open collector : Min.0V~Max. 30VC, 50mA Output frequency : Any point from 0.~0000Hz at full scale (ST90: 0.~000Hz at full scale) 4~20mA C Max. load : 600Ω Analog output Additional damping 2 outputs from instant. flow rate,temp. or density (option) 0~200sec.(variable) Alarm output Slug flow 2 High g/ml Low g/ml Totalizer Indicator Recorder Flow controller Batch controller Computer Others Sensor unit ( )m ( )m Receiving instrument In case of separate mounted type m Stand on type w/bracket and 2" U bolts 7. No. of units required 8. Application 9. Other considerations. Special fluids, such as high viscosity fluids and slurries, should be stated precisely and in detail. 2. Option

12 The specification as of July, 2005 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative:

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis

More information

High Performance Coriolis Flowmeters. Transmitter : MT9411. SUS316L, SUS316L +Alloy C, Alloy C Housing

High Performance Coriolis Flowmeters. Transmitter : MT9411. SUS316L, SUS316L +Alloy C, Alloy C Housing Liquid Gas High Performance Coriolis Flowmeters Transmitter : MT94 GENERAL SPECIFICATION GS.No.GBN053E 6 GENERAL The know-how and experience gained in our specialized domain of manufacturing flowmeters

More information

Straight-Tube Coriolis Flowmeter. SUS316L Housing. JIS 10, 20K RF, ASME/JPI 150 RF, IDF ferrule Applicable fluid

Straight-Tube Coriolis Flowmeter. SUS316L Housing. JIS 10, 20K RF, ASME/JPI 150 RF, IDF ferrule Applicable fluid Liquid Straight-Tube oriolis Flowmeter GENERAL SPEIFIATION GS.No. GENERAL Equipped with a sophisticated transmitter (self diagnosis feature, large size display, and field-reconfiguration capability using

More information

Straight-Tube Coriolis Flowmeter

Straight-Tube Coriolis Flowmeter Liquid Straight-Tube oriolis Flowmeter GENERAL SPEIFIATION GS.No. GENERAL Equipped with a sophisticated transmitter (self diagnosis feature, large size display, and field-reconfiguration capability using

More information

Cost-Effective Coriolis Flow Meters. PRO Series Meters

Cost-Effective Coriolis Flow Meters. PRO Series Meters Cost-Effective Coriolis Flow Meters CamCor TM PRO Series Meters GENERAL SPECIFICATION 50284153, Rev. 01 GENERAL Equipped with a sophisticated transmitter (including a selfdiagnostics feature, large display,

More information

High Performance Coriolis Flowmeters

High Performance Coriolis Flowmeters iquid Gas High Performance Coriolis Flowmeters GENERA SPECIFICATION GS.No.GBN120E 20 GENERA Equipped with a sophisticated transmitter (self diagnosis feature, large size display, and field reconfiguration

More information

FLOWPET-NX (Oil Service Mechanical Register)

FLOWPET-NX (Oil Service Mechanical Register) FLOWPET-NX (Oil Service Mechanical Register) GENERAL SPECIFICATION GS.No.GBB322-6-E GENERAL Flowpet-NX is an OVAL flowmeter primarily developed for boiler feed water and fuel oil measurement. Field proven

More information

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG GENERAL SPECIFICATION GS.No.GBB323E-5 GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering

More information

OVAL FLOWMETER. Meter Size: 52, 53, 55, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Magnetic coupling Outer Housing

OVAL FLOWMETER. Meter Size: 52, 53, 55, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Magnetic coupling Outer Housing OVAL FLOWMETER : 5, 53,, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Liquid GENERAL SPECIFICATION GS.No.GBB5E 7 GENERAL The OVAL flowmeter is a positive displacement type flowmeter

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

CamCor TM. CT Series Meters GENERAL FEATURES UNITS ADDITIONAL INFORMATION. GENERAL SPECIFICATION , Rev. 01

CamCor TM. CT Series Meters GENERAL FEATURES UNITS ADDITIONAL INFORMATION. GENERAL SPECIFICATION , Rev. 01 igh-performance Coriolis Flow Meters CamCor TM CT Series Meters GENERA SPECIFICATION 50284154, Rev. 01 GENERA Equipped with a sophisticated transmitter (including extensive diagnostics, a large display,

More information

CamCor TM. CT Series Meters GENERAL FEATURES UNITS ADDITIONAL INFORMATION. GENERAL SPECIFICATION , Rev. 02

CamCor TM. CT Series Meters GENERAL FEATURES UNITS ADDITIONAL INFORMATION. GENERAL SPECIFICATION , Rev. 02 igh-performance Coriolis Flow Meters CamCor TM CT Series Meters GENERA SPECIFICATION 50284154, Rev. 02 GENERA Equipped with a sophisticated transmitter (including extensive diagnostics, a large display,

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

FH CMF Coriolis Mass Flow Meters

FH CMF Coriolis Mass Flow Meters FH CMF Coriolis Mass Flow Meters 1. Introduction Coriolis Mass Flow Meters patented and developed by our company (Chinese Patent No. 03119685.3, 03149996.1) are the leading meters for precision flow measurement.

More information

FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with

FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with GENERAL SPECIFICATION FLOWPET-EG MODEL LS 7 6 7-4 GS.No.GBB323-1-E GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering applications. Field proven

More information

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter Data Sheet DS/FCB300/FCH300-EN Rev. H CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter 4-wire compact device For flow measurement of liquids and gases Measurement made easy CoriolisMaster

More information

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A

More information

OPTIMASS 1000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

Model RFT9709 Transmitter Instruction Manual

Model RFT9709 Transmitter Instruction Manual Model RFT9709 Transmitter Instruction Manual March 1999 Model RFT9709 Transmitter Instruction Manual For technical assistance, phone the Micro Motion Customer Service Department: In the U.S.A., phone

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

Mass Flowmeter CoriolisMaster FCM2000

Mass Flowmeter CoriolisMaster FCM2000 Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving

More information

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-5G

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-5G iquid Inexpensive P for oiler Feed Water and Oil FOWPET-5G GENER SPEIFITION GS.No.G324E 1 GENER FOWPET-5G is an OV flowmeter primarily intended for use in boiler feed water and fuel oil metering applications.

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

OPTIFLUX 1000 Technical Datasheet

OPTIFLUX 1000 Technical Datasheet OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when

More information

ABB FCB330 FCH350 Mass Flowmeter datasheet

ABB FCB330 FCH350 Mass Flowmeter datasheet ABB FCB330 FCH350 Mass Flowmeter datasheet http://www.manuallib.com/abb/fcb330-fch350-mass-flowmeter-datasheet.html State of the art transmitter Easy handling Data safety due to unique sensor memory concept

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Mass Flowmeter CoriolisMaster FCM2000

Mass Flowmeter CoriolisMaster FCM2000 Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving

More information

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

FW9000NN Series SERVO BALANCE-TYPE LEVEL GAUGE OUTLINE APPLICATIONS FEATURES

FW9000NN Series SERVO BALANCE-TYPE LEVEL GAUGE OUTLINE APPLICATIONS FEATURES FW9000NN Series SERVO BALANCE-TYPE LEVEL GAUGE OUTLINE FW9000NN Series is the successor to the well received and widely used FW-9000 series for its reliability and variety of long term application. Using

More information

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For water and wastewater Model LW-1 Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of

More information

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm) KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%

More information

Magnetic Flowmeter Systems

Magnetic Flowmeter Systems Series 8700 Magnetic Flowmeter Systems THE 8700 SERIES... Model 8712 C/U - Easiest to use local operator interface and works with any manufacturer s flowtubes Model 8712H/8707 High-Signal System - Pulsed

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

MaxxFlow HTC Flow Measurement for Dry Bulk Solids EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

ADDMAS CORIOLIS MASS FLOW METER

ADDMAS CORIOLIS MASS FLOW METER ADDMAS CORIOLIS MASS FLOW METER 1. General ADDMAS Series Coriolis Mass Flow meter (here after we call CMF ) is designed according to the coriolis principle. It can be widely used for the process detecting

More information

LZYN Triangle Series Mass Flow Meter

LZYN Triangle Series Mass Flow Meter LZYN Triangle Series Mass Flow Meter 1. General LZYN Triangle Series Mass Flowmeter is designed according to the Coriolis Principle.It can be widely used for the process detecting and custody transfor/fiscal

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

Magnetic Inductive Flowmeter

Magnetic Inductive Flowmeter Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange

More information

LZYN Mass Flowmeter Instruction Manual

LZYN Mass Flowmeter Instruction Manual LZYN Mass Flowmeter Instruction Manual Version 2.4 Shanghai Yinuo Instrument Co., Ltd. Address: No.7508 North Jiasong Road, Shanghai, 201804, China Tel: +86-21-3953 1213 Fax: +86-21-3953 1626 Website:

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor

More information

Mass and Volume Flow Transmitter

Mass and Volume Flow Transmitter IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,

More information

Coriolis Mass Flow Measuring System promass 40 E

Coriolis Mass Flow Measuring System promass 40 E Technical Information TI 055D/06/en 50098284 Coriolis Mass Flow Measuring System promass 40 E The new mass flow measuring system with low cost and basic functionality the economical alternative to conventional

More information

FW-9000 series MOST COMPACT & MOST LIGHT SUPER INTELLIGENT SERVO GAUGE OUTLINE FEATURES

FW-9000 series MOST COMPACT & MOST LIGHT SUPER INTELLIGENT SERVO GAUGE OUTLINE FEATURES MOST COMPACT & MOST LIGHT FW-9000 series SUPER INTELLIGENT SERVO GAUGE OUTLINE FW-9000 SUPER INTELLIGENT TANK GAUGE has been developed based on the technical and field application know-how obtained through

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions

More information

EN-2018 MAGNETIC FLOW METERS

EN-2018 MAGNETIC FLOW METERS EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance

More information

Proline Promass 40E. Technical Information

Proline Promass 40E. Technical Information Technical Information Coriolis Mass Flow Measuring System The mass flow measuring system with low cost and basic functionality. The economical alternative to conventional volume flowmeters. Application

More information

SLIDE VANE FLOW METER SPECIFICATIONS

SLIDE VANE FLOW METER SPECIFICATIONS SLIDE VANE FLOW METER SPECIFICATIONS V20051 17.09 1. Outline Slide vane flow meter is vane type positive displacement flow meter, creating high accuracy measurement and low pressure loss by decreasing

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Rotamass TI Coriolis Mass flow meter

Rotamass TI Coriolis Mass flow meter General Specifications Rotamass TI Coriolis Mass flow meter Rotamass Prime Scope of application Precise flow rate measurement of fluids and gases, multi-phase media and media with specific gas content

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy

More information

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and

More information

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE 2-wire System Level Radar TLR3000 MICROWAVE level meter GENERAL The TLR3000 is a non-contact type continuous level meter using microwaves. It detects a level by measuring a reciprocating time of a microwave

More information

ThermoPLUS Smart Temperature Transmitter

ThermoPLUS Smart Temperature Transmitter No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature

More information

DRS390 High stability, flange mounting

DRS390 High stability, flange mounting DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,

More information

OPTISONIC 7300 Technical Datasheet

OPTISONIC 7300 Technical Datasheet OPTISONIC 7300 Technical Datasheet Ultrasonic gas flowmeter Wide application range No moving parts and no pressure loss Complete solution for gasflow measurement KROHNE CONTENTS OPTISONIC 7300 1 Product

More information

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22 Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)

More information

Level Lance Model 5100

Level Lance Model 5100 Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection

More information

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For oils and fuels Model LF-1 Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run

More information

Model 8800C and Model 8800A Smart Vortex Flowmeter English Rev. JA

Model 8800C and Model 8800A Smart Vortex Flowmeter English Rev. JA Model 8800C and Model 8800A Smart Vortex Flowmeter 00809-0100-4003 English Rev. JA Product Manual Model 8800C and Model 8800A Smart Vortex Flowmeter NOTICE Read this manual before working with the product.

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only

More information

Installation guide 971 SmartRadar LTi

Installation guide 971 SmartRadar LTi Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl

More information

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature

More information

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation Ultrasonic Gas Flowmeter MPU 200 Series B Specifications Issue/Rev. 0.4 (10/11) Bulletin SSKS004 The MPU 200 Series B Ultrasonic Gas Flow Meter is a single path ultrasonic meter with non-intrusive and

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL Version 2.2 MS1016 MTF SERIES VIBRATING PROBES FOR LIQUIDS AND HYC-PKK-312 SWITCHING ISOLATOR INSTALLATION AND OPERATION MANUAL Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire,

More information

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15... Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000

More information

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector No. SS2-MGN200-0200 MagneW3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIEW The MagneW3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter

More information

Smart Displacer Level (Interface) Transmitter DLT100 Series

Smart Displacer Level (Interface) Transmitter DLT100 Series Smart Displacer Level (Interface) Transmitter DLT100 Series Equipped with FISHER FIELDVUE DLC3010 1 Introduction DLT100 series is Smart Displacer Level (Interface) Transmitter equipped with the original

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Technical Information TI 049D/06/en 50097005 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Flow rate measurement in chemical or process applications Features and benefits

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications

More information

LQ510. Density (Consistency) Meter. Introduction. Specifications EJL- 123

LQ510. Density (Consistency) Meter. Introduction. Specifications EJL- 123 Density (Consistency) Meter LQ510 Introduction The LQ510 Sanitary Density Meter is designed for application using clamp connection in the food and beverage industries. The LQ510 uses microwave phase shift

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information