1 Technical Information Proline Promag 50H, 53H Electromagnetic Flow Measuring System Flow measurement in food, beverage, pharmaceutical, or process applications Applications Electromagnetic flowmeter for birectional measurement of liquids with a minimum conductivity of 5 μs/cm: Beverages, e.g. fruit juice, beer, wine Milk products, fruit mixtures Salt solutions Acids and causic solutions, etc. Flow measurement up to 1250 gpm (4700 dm 3 /min) Fluid temperature up to 300 F (+150 C) Process pressures up to 580 psi (40 bar) CIP/SIP cleaning Stainless steel housing Approvals in the food industry/hygiene sector: 3-A authorization, EHE-tested, conformity with FA Application-specific lining materials: PFA Approvals for hazardous area: ATEX, FM, CSA, TIIS Connection to process control system: HART, PROFIBUS P/PA, FOUNATION Fieldbus, MOBUS RS485 Features and benefits Promag measuring devices offer you cost-effective flow measurement with a high degree of accuracy for a wide range of process contions. The Proline transmitter concept comprises: Modular device and operating concept resulting in a higher degree of efficiency Software options for batching, electrode cleaning and pulsating flow Uniform operating concept The tried-and-tested Promag sensors offer: No pressure loss Insensitivity to vibrations Simple installation and commissioning TI048/24/ae/09.07

2 Function and system design Measuring principle Faraday s law of induction states that a voltage is induced in a conductor moving in a magnetic field. In electromagnetic measuring, the flowing meum corresponds to the moving conductor. The induced voltage is proportional to the flow velocity and is detected by two measuring electrodes and transmitted to the amplifier. Flow volume is computed on the basis of the pipe's ameter. The constant magnetic field is generated by a switched rect current of alternating polarity. Ue I I B V Ue = B v Q = A v A Ue = induced voltage B = magnetic induction (magnetic field) = electrode gap v = flow velocity Q = volume flow A = pipe cross-section I = current strength Measuring system The measuring system consists of a transmitter and a sensor. Two versions are available: Compact version: transmitter and sensor form a single mechanical unit. Remote version: transmitter and sensor are installed separately. Transmitter: The Promag 50/53 transmitters incorporate a high impedance amplifier of 1 x ohms or greater. Promag 50 (user interface with push buttons for operation, two-line splay). Promag 53 ( Touch Control without opening the housing, four-line splay). Sensor nominal sizes: 1/12" to 4" (N 2 to 100) 2 Endress+Hauser

3 Input Measured variable Measuring range Flow rate (proportional to induced voltage) Typically v = to 33 ft/s (0.01 to 10 m/s) with the specified measuring accuracy Operable flow range Over 1000 : 1 Input signal Status input (auxiliary input): U = 3 to 30 VC, R i = 5 kω, galvanically isolated. Configurable for: totalizer(s) reset, measured value suppression, error-message reset. Status input (auyiliary input) with PROFIBUS P and MOBUS RS485: U = 3 to 30 VC, R i = 3 kω, galvanically isolated Switching level: 3 to 30 VC, independent of polarity Configurable for: totalizer(s) reset, measured value suppression, error-message reset, batching start/stop (optional), batch totalizer reset (optional) Current input (for Promag 53 only): Active/passive selectable, galvanically isolated, full scale value selectable, resolution: 3 μa, temperature coefficient: typ % o.r./ F (0.005% o.r./ C), o.r. = of reang active: 4 to 20 ma, R i 150 Ω, U out = 24 V C, short-circuit-proof passive: 0/4 to 20 ma, R i 150 Ω, U max = 30 V C Output Output signal Promag 50 Current output: active/passive selectable, galvanically isolated, time constant selectable (0.01 to 100 s), full scale value selectable, temperature coefficient: typ % o.r./ F (0.005% o.r./ C), o.r. = of reang, resolution: 0.5 μa active: 0/4 to 20 ma, R < 700 Ω (HART: R 250 Ω) passive: 4 to 20 ma, operating voltage V S 18 to 30 V C, R i 150 Ω Pulse/frequency output: passive, open collector, 30 V C, 250 ma, galvanically isolated. Frequency output: full scale frequency 2 to 1000 Hz (f max = 1250 Hz), on/off ratio 1:1, pulse width max. 10 s. Pulse output: pulse value and pulse polarity selectable, max. pulse width configurable (0.5 to 2000 ms) PROFIBUS P interface: Transmission technology (Physical ayer): RS485 in accordance with ANSI/TIA/EIA-485-A: 1998, galvanically isolated Profile version 3.0 ata transmission rate: 9.6 kbaud to 12 MBaud Automatic data transmission rate recognition Function blocks: 1 x analog input, 3 x totalizer Output data: volume flow, totalizer Input data: positive zero return (ON/OFF), totalizer control, value for local splay Cyclic data transmission compatible with previous model Promag 33 Bus address adjustable via miniature switches or local splay (optional) at the measuring device Endress+Hauser 3

4 PROFIBUS PA interface: Transmission technology (Physical ayer): IEC (MBP), galvanically isolated Profile version 3.0 Current consumption: 11 ma Permissible supply voltage: 9 to 32 V Bus connection with integrated reverse polarity protection Error current FE (Fault isconnection Electronic): 0 ma Function blocks: 1 x analog input, 1 x totalizer Output data: volume flow, totalizer Input data: positive zero return (ON/OFF), control totalizer, value for local splay Cyclic data transmission compatible with previous model Promag 33 Bus address adjustable via miniature switches or local splay (optional) at the measuring device Promag 53 Current output: active/passive selectable, galvanically isolated, time constant selectable ( s), full scale value selectable, temperature coefficient: typically 0.005% o.r./ C (o.r. = of reang), resolution: 0.5 μa active: 0/4 to 20 ma, R < 700 Ω (HART: R 250 Ω) passive: 4 to 20 ma, operating voltage V S 18 to 30 V C, R i 150 Ω Pulse/frequency output: active/passive selectable, galvanically isolated (Ex i version: only passive) active: 24 V C, 25 ma (max. 250 ma during 20 ms), R > 100 Ω passive: open collector, 30 V C, 250 ma Frequency output: full scale frequency 2 to Hz (f max = Hz), EEx-ia: 2 to 5000 Hz; on/off ratio 1:1; pulse width max. 10 s. Pulse output: pulse value and pulse polarity adjustable, pulse width configurable (0.05 to 2000 ms) PROFIBUS P interface: Transmission technology (Physical ayer): RS485 in accordance with ANSI/TIA/EIA-485-A: 1998, galvanically isolated Profile version 3.0 ata transmission rate: 9.6 kbaud to 12 MBaud Automatic data transmission rate recognition Function blocks: 2 x analog input, 3 x totalizer Output data: volume flow, calculated mass flow, totalizer 1 to 3 Input data: positive zero return (ON/OFF), totalizer control, value for local splay Cyclic data transmission compatible with previous model Promag 33 Bus address adjustable via miniature switches or local splay (optional) at the measuring device Available output combination Page 7 ff. PROFIBUS PA interface: Transmission technology (Physical ayer): IEC (MBP), galvanically isolated Profile version 3.0 Current consumption: 11 ma Permissible supply voltage: 9 to 32 V Bus connection with integrated reverse polarity protection Error current FE (Fault isconnection Electronic): 0 ma Function blocks: 2 x analog input, 3 x totalizer Output data: volume flow, calculated mass flow, totalizer 1 to 3 Input data: positive zero return (ON/OFF), totalizer control, value for local splay Cyclic data transmission compatible with previous model Promag 33 Bus address adjustable via miniature switches or local splay (optional) at the measuring device 4 Endress+Hauser

5 MOBUS interface: Transmission technology (Physical ayer): RS485 in accordance with ANSI/TIA/EIA-485-A: 1998, galvanically isolated MOBUS device type: Slave Adress range: 1 to 247 Bus address adjustable via miniature switches or local splay (optional) at the measuring device Supported MOBUS function codes: 03, 04, 06, 08, 16, 23 Broadcast: supported with the function codes 06, 16, 23 Transmission mode: RTU oder ASCII Supported baudrate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, Baud Response time: irect data access = typically 25 to 50 ms Auto-scan buffer (data range) = typically 3 to 5 ms Available output combination Page 7 ff. FOUNATION Fieldbus interface: FOUNATION Fieldbus H1 Transmission technology (Physical ayer): IEC (MBP), galvanically isolated ITK version 4.01 Current consumption: 12 ma Error current FE (Fault isconnection Electronic): 0 ma Bus connection with integrated reverse polarity protection Function blocks: 5 x analog input, 1 x screte output, 1 x PI Output data: volume flow, calculated mass flow, temperature, totalizer 1 to 3 Input data: positive zero return (ON/OFF), reset totalizer ink Master (M) functionality is supported Signal on alarm Current output failure response selectable (e.g. in accord. with NAMUR Recom. NE 43) Pulse/frequency output failure response selectable Status output (Promag 50) non-conductive by fault or power supply failure Relay output (Promag 53) de-energized by fault or power supply failure oad See Output signal Switching output Status output (Promag 50, Promag 53): Open collector, max. 30 V C / 250 ma, galvanically isolated. Configurable for: error messages, Empty Pipe etection (EP), flow rection, limit values. Relay outputs (Promag 53): Normally closed (NC or break) or normally open (NO or make) contacts available (default: relay 1 = NO, relay 2 = NC), max. 30 V / 0.5 A AC; 60 V / 0.1 A C, galvanically isolated. Configurable for: error messages, Empty Pipe etection (EP), flow rection, limit values, batching contacts. ow flow cutoff alvanic isolation Switch points for low flow cutoff are selectable All circuits for inputs, outputs, and power supply are galvanically isolated from each other. Endress+Hauser 5

6 Power supply Electrical connection Measuring unit A B C d g b d g b a a a b d/(g) (d) HART* PROFIBUS PA* FOUNATION Fieldbus* f d e PA( )/FF( ) 27 PA(+)/FF(+) f d e N (-) 2 1 (+)1 c b N (-) 1 (+) 2 1 c b PROFIBUS P* PROFIBUS P** MOBUS RS485** A (Rx/Tx-N) 27 B (Rx/Tx-P) f d e g A (Rx/Tx-N) 27 B (Rx/Tx-P) f d e g N (-) 1 (+) 2 1 c b N (-) 1 (+) 2 1 c b Connecting the transmitter, cable cross-section max. 16 AW (2.5 mm 2 ) a AView A (field housing) BView B (stainless steel field housing) CView C (wall-mount housing) *) non-changeable communication board **) changeable communication board a Cover of the connection compartment b Cable for power supply: 85 to 260 VAC, 20 to 55 VAC,16 to 62 VC Terminal No. 1: 1 for AC, + for C Terminal No. 2: N for AC, - for C c round terminal for protective conductor d Signal cable: see Terminal assignment Page 7 ff. Fieldbus cable: Terminal No. 26: P (A) / PA (+) / FF (+) / MOBUS RS485 (A) / (PA, FF: with reverse polarity protection) Terminal No. 27: P (B) / PA (-) / FF (-) / MOBUS RS485 (B) / (PA, FF: with reverse polarity protection) e round terminal for signal-cable shield / Fieldbus cable / RS485 line f Service connector for connecting service interface FXA 193 (Fieldcheck, Tof Tool - Fieldtool Package) g Signal cable: see Terminal assignment Page 7 ff. Cable for external termination (only for PROFIBUS P with fixed assignment communication board): Terminal No. 24: +5 V Terminal No. 25: N 6 Endress+Hauser

7 Terminal assignment, Promag 50 Terminal No. (inputs / outputs) Order variant 20 (+) / 21 ( ) 22 (+) / 23 ( ) 24 (+) / 25 ( ) 26 (+) / 27 ( ) 50***-***********W 50***-***********A Frequency output 50***-*********** Status input Status output Frequency output 50***-***********H Current output HART Current output HART Current output HART PROFIBUS PA 50***-***********J 50***-***********S 50***-***********T round connection, power supply Page 6 +5 V (external termination) Frequency output IS, passive Frequency output Ex i, passive PROFIBUS P Current output IS active, HART Current output IS passive, HART Terminal assignment, Promag 53 The inputs and outputs on the communication board can be either permanently assigned or variable, depenng on the version ordered (see table). Replacements for modules which are defective or which have to be replaced can be ordered as accessories. Terminal No. (inputs / outputs) Order variant 20 (+) / 21 ( ) 22 (+) / 23 ( ) 24 (+) / 25 ( ) 26 (+) / 27 ( ) Fixed communication boards (fixed assignment) 53***-***********A Frequency output 53***-***********B Relay output 2 Relay output 1 Frequency output 53***-***********F 53***-*********** 53***-***********H 53***-***********J 53***-***********K 53***-***********Q Status input 53***-***********S 53***-***********T Flexible communication boards Frequency output IS Frequency output IS 53***-***********C Relay output 2 Relay output 1 Frequency output 53***-*********** Status input Relay output Frequency output 53***-*********** Status input Relay output 2 Relay output 1 Current output HART Current output HART PROFIBUS PA IS FOUNATION Fieldbus, IS PROFIBUS PA PROFIBUS P FOUNATION Fieldbus MOBUS RS485 Current output, IS active, HART Current output, IS passive, HART Current output HART Current output HART Current output HART Endress+Hauser 7

8 Terminal No. (inputs / outputs) Order variant 20 (+) / 21 ( ) 22 (+) / 23 ( ) 24 (+) / 25 ( ) 26 (+) / 27 ( ) 53***-***********M Status input Frequency output Frequency output Current output HART 53***-***********N Current output Frequency output Status input MOBUS RS485 53***-***********P Current output Frequency output Status input PROFIBUS P 53***-***********V Relay output 2 Relay output 1 Status input PROFIBUS P 53***-***********2 Relay output Current output Frequency output 53***-***********4 Current input Relay output Frequency output Current output HART Current output HART 53***-***********5 Status input Current input Frequency output Current output HART 53***-***********7 Relay output 2 Relay output 1 Status input MOBUS RS485 round connection, power supply Page 6 Electrical connection remote version Electrode circuit Meas. signal Pipe EP Coil circuit S1 E1 E2 S2 N E S brown white green yellow 2 1 n.c. n.c. n.c E1 E2 N E 1-1/2 to 4 1/12 to 1 n.c. = isolated cable shields, not connected F06-5xHxxxxx-04-xx-xx-en-001 Cable entry Power-supply and signal cables (inputs/outputs): Cable entry M20 x 1.5 (8 to 12 mm) Threads for cable entries 1/2" NPT, 1/2" Connecting cable for remote version: Cable entry M20 x 1.5 (8 to 12 mm) Threads for cable entries 1/2" NPT, 1/2" 8 Endress+Hauser

9 Cable specifications remote version Coil cable: 2 x 18 AW (0.75 mm 2 ) PVC cable with common, braided copper shield (Ø approx. 0.28" / 7 mm) Conductor resistance: 37 Ω/km Capacitance core/core, shield grounded: 120 pf/m Permanent operating temperature: -5 to +180 F ( 20 to +80 C) Cable cross-section: max. 16 AW (2.5 mm 2 ) Signal cable: 3 x 20 AW (0.38 mm 2 ) PVC cable with common, braided copper shield (Ø approx. 0.28" / 7 mm) and invidually shielded cores. With Empty Pipe etection (EP): 4 x 20 AW (0.38 mm 2 ) PVC cable with common, braided copper shield (Ø approx. 0.28" / 7 mm) and invidually shielded cores. Conductor resistance: 50 Ω/km Capacitance core/shield: 420 pf/m Permanent operating temperature: -5 to +180 F ( 20 to +80 C) Cable cross-section: max. 16 AW (2.5 mm 2 ) a b a = signal cable, b = coil current cable (cross-section: max. 16 AW / 2.5 mm 2 ) 1 = core, 2 = core insulation, 3 = core shield, 4 = core jacket, 5 = core strengthening, 6 = cable shield, 7 = outer jacket A Optionally, Endress+Hauser also supplies flexible metal conduit. We recommend such cables for the following cases: Cables laid underground anger of rodent attack evice used with ingress protection NEMA 6P (IP 68) Operation in zones of severe electrical interference: The measuring device complies with the general safety requirements in accordance with EN 61010, the EMC requirements of EN 61326/A1, and NAMUR recommendation NE 21. Caution! rounng is by means of the ground terminals provided for the purpose inside the connection housing. Keep the stripped and twisted lengths of cable shield to the terminals as short as possible. Supply voltage 85 to 260 VAC, 45 to 65 Hz 20 to 55 VAC, 45 to 65 Hz 16 to 62 VC PROFIBUS PA and FOUNATION Fieldbus Non-hazardous: 9 to 32V C Intrinsically safe: 9 to 24 VC Explosion proof: 9 to 32 VC Power consumption AC: <15 VA (inclung sensor) C: <15 W (inclung sensor) Switch-on current: max A (< 50 ms) at 24 VC max. 3 A (< 5 ms) at 260 VAC Endress+Hauser 9

10 Power supply failure Potential equalization asting min. 1 power cycle: EEPROM or T-AT (Promag 53 only) retain the measuring system data in the event of a power supply failure S-AT: exchangeable data storage chip which stores the data of the sensor (nominal ameter, serial number, calibration factor, zero point, etc.) Perfect measurement is only ensured when the meum and the sensor have the same electrical potential. Metal process connections Potential matching usually takes place over the metallic process connection in contact with meum process connections which are rectly mounted on the measuring transmitter. This usually means that adtional potential matching measures are unnecessary. Plastic process connections For plastic process connections, potential matching must be ensured between sensor and meum using adtional ground rings. If these ground rings are missing, this can influence accuracy or destroy the measuring transmitter through the electrochemical decomposition of electrodes Allen screw (process connection) 2 O-ring seals 3 Plastic washer (spacer) or ground ring 4 Sensor A When using ground rings, note the following points: epenng on the option ordered, plastic washers may be installed at the process connections instead of ground rings. These plastic washers serve only as spacers and have no potential equalization function. In adtion, they provide a sealing function at the interface between the sensor and process connection. For this reason, with process connections without ground rings, these plastic washers/seals must not be removed, or must always be installed. round rings can be ordered separately from Endress+Hauser as an accessory. Also make sure that the ground rings are compatible with the electrode material. Otherwise the danger exists that the electrodes could be destroyed by electrochemical corrosion. You can find material data on Page 38 ff. round rings, incl. seals, are mounted inside the process connection. This has no influence on the installation length. You can find the mensions of ground rings on Page Endress+Hauser

11 Performance characteristics Reference operating contions To IN EN and VI/VE 2641: Meum temperature: +28 C ± 2 K Ambient temperature: +22 C ± 2 K Warm-up period: 30 minutes Installation: Inlet run >10 x ia. Outlet run > 5 x ia. Sensor and transmitter grounded. Sensor centered relative to the pipe. Maximum measured error Promag 50: Pulse output: ± 0.5% o.r. ± 1 mm/s (o.r. = of reang) Current output: plus typically ± 5 μa Promag 53: Pulse output: ± 0.2% o.r. ± 2 mm/s (o.r. = of reang) Current output: plus typically ± 5 μa Supply voltage fluctuations have no effect within the specified range. [%] % 0.2 % (1) 6 (2) 13 (4) 20 (6) 26 (8) 33 (10) v in ft/s [m/s] Max. measured error in % of reang F06-5xxxxxxx-05-xx-xx-xx-000 Repeatability max. ± 0.1% o.r. ± 0.5 mm/s (o.r. = of reang) Endress+Hauser 11

12 Operating contions Installation contions Installation instructions Mounting location Correct measuring is possible only if the pipe is full. Avoid the following locations: Highest point of a pipeline. Risk of air accumulating. irectly upstream from an open pipe outlet in a vertical pipe. h 2 x ia F06-5xxxxxxx xx-000 Installation of pumps o not install the sensor on the intake side of a pump. This precaution is to avoid low pressure and the consequent risk of damage to the lining of the measuring tube. Information on the lining's resistance to partial vacuum can be found on Page 18. It might be necessary to install pulse dampers in systems incorporating reciprocating, aphragm or peristaltic pumps. Information on the measuring system's resistance to vibration and shock can be found on Page 17. F06-5xxxxxxx xx Endress+Hauser

13 Partially filled pipes Partially filled pipes with graents necessitate a drain-type configuration. The Empty Pipe etection (EP) function offers adtional protection by detecting empty or partially filled pipes. Caution! Risk of solids accumulating. o not install the sensor at the lowest point in the drain. It is advisable to install a cleaning valve. 2 x ia. 5 x ia. F06-5xxxxxxx xx-002 Vertical pipes Install a siphon (b) or a vent valve (a) downstream of the sensor in vertical pipes longer than 15 ft (5 meters). This precaution is to avoid low pressure and the consequent risk of damage to the lining of the measuring tube. These measures also prevent the system losing prime, which could cause air inclusions. Information on the lining s resistance to partial vacuum can be found on Page 18. a b >15ft(5m) a = vent valve, b = siphon F06-5xxxxxxx xx-003 Endress+Hauser 13

14 Orientation An optimum orientation helps avoid gas and air accumulations and deposits in the measuring tube. Promag, nevertheless, supplies a range of options and accessories for correct measuring of problematic meums: Electrode Cleaning Circuitry (ECC) to remove electrically conductive deposits in the measuring tube, e.g. in accretive meums. Empty Pipe etection (EP) for recognition of partially filled measuring tubes, or for degassing meums or for applications with fluctuating process pressure (only for 1/2" to 4" / N 15 to 100). Vertical orientation: This orientation is ideal for self-emptying piping systems and for use in conjunction with Empty Pipe etection. F06-5xxxxxxx xx-004 Horizontal orientation: The measuring electrode-plane should be horizontal. This prevents brief insulation of the two electrodes by entrained air bubbles. Caution! Empty Pipe etection functions correctly only when the measuring device is installed horizontally and the transmitter housing is facing upward. Otherwise there is no guarantee that Empty Pipe etection will respond if the measuring tube is only partially filled or empty. A A 1 = EP electrode (Empty Pipe etection) except for Promag H 1/12" and 5/32" (N 2, 4) sensors 2 = Measuring electrodes (signal detection) F06-5xxxxxxx xx-xx Endress+Hauser

15 Vibrations Secure the piping and the sensor if vibration is severe. Caution! It is advisable to install sensor and transmitter separately if vibration is excessively severe. Information on resistance to vibration and shock can be found on Page 17. The sensor might require support or adtional attachments, depenng on the application and the length of the piping run. When plastic process connections are used, the sensor must be adtionally supported mechanically. A wall-mounting kit can be ordered separately from Endress+Hauser as an accessory. >30ft(10m) F06-5xxxxxxx xx-006 Inlet and outlet runs If possible, install the sensor well clear of fittings such as valves, T-pieces, elbows, etc. Compliance with the following requirements for the inlet and outlet runs is necessary in order to ensure measuring accuracy: Inlet run 5 x ia. Outlet run 2 x ia. 5 x ia. 2 x ia. F06-5xxxxxxx xx-005 Endress+Hauser 15

16 Adapters Suitable adapters to IN EN 545 (double flange junction sections) can be used to install the sensor in largerameter pipes. The resultant increase in the rate of flow improves measuring accuracy with very slow-moving fluids. The nomogram shown here can be used to calculate the pressure loss caused by reducers and expanders. The nomogram applies only to fluids of viscosity similar to water. 1. Calculate the ratio of the ameters d/. 2. From the nomogram read off the pressure loss as a function of flow velocity (downstream from the reduction) and the d/ ratio. psi [mbar] 1.45 (100) 26 ft/s 8 m/s 23 ft/s 7 m/s max. 8 d 0.14 (10) (1) 20 ft/s 6 m/s 16 ft/s 5 m/s 13 ft/s 4 m/s 10 ft/s 3 m/s 6 ft/s 2 m/s 3 ft/s 1 m/s d/ F06-5xxxxxxx xx-xx-000 ength of connecting cable Permissible cable length max depends on the conductivity of the meum. A minimum conductivity of 20 μs/cm is required for measuring demineralized water. ( S/cm] 200 max (10) 330 (100) 650 (200) ft [m] max ray shaded area = permissible range for meum conductivity max = length of connecting cable in feet [m] Meum conductivity in [μs/cm] F06-5xxxxxxx-05-xx-xx-xx-006 In order to ensure measuring accuracy, moreover, comply with the following instructions when installing the remote version: Secure the cable run or route the cable in a conduit. Movement of the cable can falsify the measuring signal, particularly if the conductivity of the meum is low. Route the cable well clear of electrical machines and switching elements. Ensure potential equalization between sensor and transmitter, if necessary. 16 Endress+Hauser

17 Environment Ambient temperature Transmitter: Standard: -5 to +140 F ( 20 to +60 C) Optional: -40 to +140 F ( 40 to +60 C) Note! At ambient temperatures below -5 F ( 20 C) the readability of the splay may be impaired. Sensor: Flange material carbon steel: 15 to 140 F ( 10 to +60 C) Flange material stainless steel: -40 to +140 F ( 40 to +60 C) Caution! It is not allowed to use the device beyond the min. and max. lining specified temperature values ( Meum temperature range ). Note the following points: Install the device at a shady location. Avoid rect sunlight, particularly in warm climatic regions. If both fluid and ambient temperatures are high, install the transmitter at a remote location from the sensor ( Meum temperature range ). Note! HE or Harsh Environment Protection for sensor: Provides enhanced moisture ingress protection for humid ambient environments. Apply in applications with severe temperature cycling and humid environments. Refer to ordering information, page 43. Storage temperature egree of protection The storage temperature corresponds to the ambient temperature range of the transmitter and sensor (see Ambient temperature ). The measuring device must be protected against rect sunlight during storage in order to avoid unacceptably high surface temperatures. Choose a storage location where moisture does not collect in the measuring device. This will help prevent fungus and bacteria infestation which can damage the liner. o not remove the protective plates or caps on the process connections until the device is ready to install. NEMA 4X (IP 67) for transmitter and sensor Shock and vibration resistance Acceleration up to 2 g by analogy with IEC CIP cleaning SIP cleaning Electromagnetic compatibility (EMC) Possible Possible To EN 61326/A1 and NAMUR recommendation NE 21 Endress+Hauser 17

18 Process contions Meum temperature range The permissible meum temperature depends on the sensor and the sealing material: Sensor: 1/12" to 4" (N 2 to 100): -5 to +300 F ( 20 to +150 C) Seal: EPM: -5 to +265 F ( 20 to +130 C) Silicon: -5 to +300 F ( 20 to +150 C) Viton: -5 to +300 F ( 20 to +150 C) Kalrez: -5 to +300 F ( 20 to +150 C) Conductivity Minimum conductivity: 5 μs/cm for fluids generally 20 μs/cm for demineralised water Note that in the case of the remote version, the minimum conductivity is also influenced by the length of the connecting cable see ength of connecting cable Meum pressure range (nominal pressure) The permissible nominal pressure depends on the process connection and seal: 580 psi (40 bar): flange, weld nipple (with O-ring seal) 230 psi (16 bar): all other process connections Pressure tightness (liner) Nominal ameter Measuring tube lining Resistance to partial vacuum of measuring tube lining imit values for abs. pressure [mbar] at various fluid temperatures [inch] 75 F 175 F 212 F 265 C 300 F 356 F 2 to 100 1/12 to 4" PFA imiting flow The ameter of the pipe and the flow rate determine the nominal ameter of the sensor. The optimum velocity of flow is 6 to 10 ft/s (2 to 3 m/s). The velocity of flow (v), moreover, has to be matched to the physical properties of the meum: v > 6 ft/s (2 m/s:) for mea forming coatings, e.g. in full-fat milk, etc. Flow characteristics (SI units) Nominal ameter Recommended flow rate Factory settings [inch] Min./max. full scale value (v ~ 0.3 or 10 m/s) Full scale value (v ~ 2.5 m/s) Pulse weighting (~ 2 pulse/s) Creepage (v ~ 0.04 m/s) 2 1/12" 0.06 to 1.8 dm 3 /min 0.5 dm 3 /min dm dm 3 /min 4 5/32" 0.25 to 7 dm 3 /min 2 dm 3 /min dm dm 3 /min 8 5/16" 1 to 30 dm 3 /min 8 dm 3 /min 0.10 dm dm 3 /min 15 1/2" 4 to 100 dm 3 /min 25 dm 3 /min 0.20 dm dm 3 /min 25 1" 9 to 300 dm 3 /min 75 dm 3 /min 0.50 dm 3 1 dm 3 /min /2" 25 to 700 dm 3 /min 200 dm 3 /min 1.50 dm 3 3 dm 3 /min 50 2" 35 to 1100 dm 3 /min 300 dm 3 /min 2.50 dm 3 5 dm 3 /min /2" 60 to 2000 dm 3 /min 500 dm 3 /min 5.00 dm 3 8 dm 3 /min 80 3" 90 to 3000 dm 3 /min 750 dm 3 /min 5.00 dm 3 12 dm 3 /min 100 4" 145 to 4700 dm 3 /min 1200 dm 3 /min dm 3 20 dm 3 /min 18 Endress+Hauser

19 Flow characteristics (US units) Nominal ameter Recommended flow rate Factory settings [inch] Min./max. full scale value (v ~ 1.0 or 33 ft/s) Full scale value (v ~ 8 ft/s) Pulse weighting (~ 2 pulse/s) Creepage (v ~ 0.1 ft/s) 1/12" gal/min 0.1 gal/min gal gal/min 5/32" gal/min 0.5 gal/min gal gal/min 5/16" gal/min 2 gal/min 0.02 gal gal/min 1/2" gal/min 6 gal/min 0.05 gal 0.10 gal/min 1" gal/min 18 gal/min 0.20 gal 0.25 gal/min 1 1/2" gal/min 50 gal/min 0.50 gal 0.75 gal/min 2" gal/min 75 gal/min 0.50 gal 1.25 gal/min 2 1/2" gal/min 130 gal/min 1 gal 2.0 gal/min 3" gal/min 200 gal/min 2 gal 2.5 gal/min 4" gal/min 300 gal/min 2 gal 4.0 gal/min Pressure loss Measuring-tube specifications With 5/16" to 4" (N 8 to 100), no pressure loss if the sensor is installed in a pipe of the same nominal ameter. Pressure losses for configurations incorporating adapters to IN EN 545 Page 16. Nominal iameter Pressure rating * Inside ameter of measuring tube ** [inch] EN (IN) [bar] PFA, inches (mm) 2 1/12" 230 / 580 psi (PN 16 / PN 40) 0.09 (2.25) 4 5/32" 230 / 580 psi (PN 16 / PN 40) 0.12 (4.5) 8 5/16" 230 / 580 psi (PN 16 / PN 40) 0.35 (9.0) 15 1/2" 230 / 580 psi (PN 16 / PN 40) 0.63 (16.0) 1" 230 / 580 psi (PN 16 / PN 40) 0.89 (22.6) / 580 psi (PN 16 / PN 40) 1.02 (26.0) /2" 230 psi (PN 16) 1.39 (35.3) 50 2" 230 psi (PN 16) 1.89 (48.1) /2" 230 psi (PN 16) 2.36 (59.9) 80 3" 230 psi (PN 16) 2.86 (72.6) 100 4" 230 psi (PN 16) 3.84 (97.5) * The pressure rating depends on the process connections and the seals (see Page 18). ** Inside ameters of process connections Page 26 ff. Endress+Hauser 19

20 Mechanical construction esign / mensions imensions: Wall-mount housing (non hazardous area and II3 / zone 2) Esc - + E 6.27" (159.5) 9.84" (250) 3.56" (90.5) 8.46" (215) 3.54" (90) 5.31" (135) 1.77" (45) > 1.97" (50) 3.18" (81) 2.08" (53) 3.18" (81) 4.01" (102) 3.20" (81.5) 2.08" (53) 3.74" (95) 0.45" (11.5) 7.55" (192) 0.45" (11.5) A imensions: Remote field housing (II2 / zone 1) 10.4" (265) 9.53" * (242) 9.45 (240) 8.54 * (217) ~8.11 (206) 7.32 (186) 6.57" (167) 13.9" (355) 3.94" (100) 5.24" (133) 7.40" (188) * Blind version Æ 0.34" (8.6 M8) 3.94" (100) 4.84" (123) A Endress+Hauser

21 There is a separate mounting kit for the wall-mounted housing. It can be ordered from Endress+Hauser as an accessory. The following installation variants are possible: Panel-mounted installation Pipe mounting Panel-mounted installation (210 ) (245 ) 4.33 (110) A Pipe mounting Ø 0.79 to 2.75 (20 to 70) ~6.10 (155) A Endress+Hauser 21

22 Compact version, aluminum field housing 1/12" to 1" (N 2 to 25) 8.94" (227) 8.15" * (207) 7.68" (195) 6.61" (168) 6.30" (160) 9.92" (252) 12.5" (317) M K I 2.56" (65) * Blind option mension F06-53Hxxxxx xx-xx-001 Compact version, stainless-steel field housing 1/12" to 1" (N 2 to 25) 8.66" (220) 6.02" (153) 6.7" (171) 10.3" (263) 12.9" (328) M K I 2.56" (65) F06-53Hxxxxx xx-xx-002 Nominal size Pressure ** I K M [inch] psi in (mm) in (mm) in (mm) 2 1/12 230/ (2.25) 3.39 (86) 1.69 (43) M 6x4 4 5/32 230/ (4.5) 3.39 (86) 1.69 (43) M 6x4 8 5/16 230/ (9.0) 3.39 (86) 1.69 (43) M 6x4 15 1/2 230/ (16.0) 3.39 (86) 1.69 (43) M 6x / (22.6) 3.39 (86) 2.09 (53) M 6x / (26.0) 3.39 (86) 2.09 (53) M 6x4 Fitting length depends on process connections Page 27 ff. ** The permissible nominal pressure depends on the process connection and seal: 580 psi (40 bar): flange EN (IN 2501), welded nipples for IN EN ISO 1127 pipes and OT (with O-ring seal) 230 psi (16 bar): all other process connections 22 Endress+Hauser

23 Remote version 1/12" to 1" (N 2 to 25) 4.92" (125) 2.76" (70) 2.95" (75) B C 8.39" (213) M K I F06-xxHxxxxx xx-xx-001 Nominal size Pressure * I B C K M [inch] psi in (mm) in (mm) in (mm) in (mm) in (mm) 2 1/12 230/ (2.25) 3.39 (86) 5.83" (148) 2.56 (65) 1.69 (43) M 6x4 4 5/32 230/ (4.5) 3.39 (86) 5.83" (148) 2.56 (65) 1.69 (43) M 6x4 8 5/16 230/ (9.0) 3.39 (86) 5.83" (148) 2.56 (65) 1.69 (43) M 6x4 15 1/2 230/ (16.0) 3.39 (86) 5.83" (148) 2.56 (65) 1.69 (43) M 6x / (22.6) 3.39 (86) 5.83" (148) 2.56 (65) 2.09 (53) M 6x / (26.0) 3.39 (86) 5.83" (148) 2.56 (65) 2.09 (53) M 6x4 Fitting length depends on process connections Page 27 ff. imensions wall-mounted housing Page 20 * The permissible nominal pressure depends on the process connection and seal: 580 psi (40 bar): flange EN (IN 2501), welded nipples for IN EN ISO 1127 pipes and OT (with O-ring seal) 230 psi (16 bar): all other process connections Wall-mounting kit 4.33" (110) 3.46" (88) 0.28" (7) 5.51 (140) 4.92" (125) 4.72" (120) F06-xxHxxxxx xx-000 Endress+Hauser 23

24 Compact version, aluminum field housing 1-1/2" to 4" (N 40 to 100) 8.94" (227) 8.15" * (207) 7.68" (195) 6.61" (168) M 6.30" (160) B A I K C * Blind option mension F06-53Hxxxxx xx-xx-000 Compact version, stainless-steel field housing 1-1/2" to 4" (N 40 to 100) 8.66" (220) 6.02" (153) 6.7" (171) B A M I K C F06-53Hxxxxx xx-xx-003 Nominal Press. I A * B * C K M [inch] psi in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) (mm) /2" (35.3) 5.51 (140) 12.6 (319) 10.0 (255) 2.52 (64) 5.03 (128) M 8x4 50 2" (48.1) 5.51 (140) 13.5 (344) 10.5 (267) 3.03 (77) 6.02 (153) M 8x /2" (59.9) 5.51 (140) 13.5 (344) 10.5 (267) 3.03 (77) 6.02 (153) M 8x4 80 3" (72.6) 7.87 (200) 15.5 (394) 11.5 (292) 4.02 (102) 7.99 (203) M 12x " (97.5) 7.87 (200) 15.5 (394) 11.5 (292) 4.02 (102) 7.99 (203) M 12x4 Fitting length depends on process connections Page 27 ff. * imensions for aluminum housing, see table below for stainless steel housing. A, SS housing B, SS housing in (mm) in (mm) 13.0 (330) 10.5 (266) 14.0 (355) 10.9 (278) 14.0 (355) 10.9 (278) 16.0 (405) 11.9 (303) 16.0 (405) 11.9 (303) 24 Endress+Hauser

25 Remote version 1-1/2" to 4" (N 40 to 100) 4.92" (125) 2.76" (70) 2.95" (75) B A M C I K F06-xxHxxxxx xx-xx-000 Nominal size Press. I A B C K M [inch] psi in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) /2" (35.3) 5.51 (140) 8.50 (216) 5.96 (151.5) 2.54 (64.5) 5.03 (128) M 8x4 50 2" (48.1) 5.51 (140) 9.49 (241) 6.46 (164.0) 3.03 (77) 6.02 (153) M 8x /2" (59.9) 5.51 (140) 9.49 (241) 6.46 (164.0) 3.03 (77) 6.02 (153) M 8x4 80 3" (72.6) 7.87 (200) 11.4 (290) 7.42 (188.5) 3.99 (101.5) 7.99 (203) M 12x " (97.5) 7.87 (200) 11.4 (290) 7.42 (188.5) 3.99 (101.5) 7.99 (203) M 12x4 Fitting length depends on process connections Page 27 ff. imensions wall-mounted housing Page 20 Endress+Hauser 25

26 Front view 1/12" to 1" (N 2 to 25), without process connection 2.36" (60) 1.64" (41.6) A ±0.004" (0.1) ±0.004" (0.1) 1/12 to 1/2 (N 2 to 15) C 1.34" 0-0.1" (34 ) " A-A 0.15" (4) 2.76" (70) 1.91" (48.5) B ±0.004" (0.1) ±0.004" (0.1) 1 (N 255) 1.73" 0-0.1" (44 ) " B-B 0.15" (4) A ±0.004" (0.1) ±0.004" (0.1) 0.94" (24) 1.65" (42) 0.33" (8.5) M6 0.23" (6) B ±0.004" (0.1) ±0.004" (0.1) 1.10" (28) 2.05" (52) 0.33" (8.5) M6 0.23" (6) F06-5xHxxxxx xx-000 Nominal size (IN) C in (mm) (IN) in ([mm) (ANSI) inches 1/12" to 5/16" (2 to 8) 0.35 (9) 1/2" (15) 0.63 (16) 25 (IN) 1.02 (26) 1" ANSI (25) 0.89" 26 Endress+Hauser

27 Process connections with O-ring seals 1/12" to 1" (N 2 to 25) Weld nipples for IN / 316 SS 5*H**-B*********** Sensor Fits to H x B N Piping IN EN ISO to x x x x (IN) 33.7 x x 52 Fitting length = (2 x ) + 86 mm Weld nipples for IPS/SMS pipe / 316 SS 5*H**-C*********** Sensor Fits to H x B N Piping O/SMS 2 to x x x x (1" ANSI) 33.7 x x 52 Fitting length = (2 x ) + 86 mm F06-xxHxxxxx-06- F06-xxHxxxxx Flange PN 40 EN (IN 2501), Form B / 316 SS 5*H**-*********** Sensor Fits to K M H x B N Flange EN (IN 2501) 2 to 8 N x 42 M 15 N x 42 K 25 (IN) N x 52 Fitting length = (2 x ) + 86 mm Fitting length to VW (200 mm) F06-xxHxxxxx xx-014 Flange CI 150 / ANSI B / 316 SS 5*H**-E*********** Sensor Fits to K M H x B Flange ANSI B16.5 inches inches inches inches inches inches 1/12" to 5/16" 1/2" x 1.65 M K 1/2" 1/2" x " 1" x 2.05 Fitting length = (2 x ) " (86 mm) F06-xxHxxxxx xx-015 Endress+Hauser 27

28 Flange 20 K / JIS B / 316 SS 5*H**-F*********** Sensor Fits to K M H x B N Flange B to 8 N x 42 M 15 N x 42 K 25 (IN) N x 52 Fitting length = (2 x ) + 86 mm F06-xxHxxxxx xx-016 Flange PN 16 / EN (IN 2501) PVF 5*H**-*********** Sensor Fits to M K H x B N Flange EN (IN 2501) 2 to 8 N x 42 M 15 N x 42 K 25 (IN) N x 52 Fitting length = (2 x ) + 86 mm Fitting length to VW (200 mm) The requisite ground rings can be ordered as accessories (Order No. K5HR-****) F06-xxHxxxxx xx-029 Flange CI 150 / ANSI B16.5 PVF 5*H**-H*********** Sensor Fits to Flange M K H x B ANSI B16.5 inches inches inches inches inches inches 1/12" to 5/16" 1/2" x 1.65 M 1/2" 1/2" x 1.65 K 1" 1" x 2.05 Fitting length = (2 x ) " (86 mm) The requisite ground rings can be ordered as accessories (Order No. K5HR-****) F06-xxHxxxxx xx-029 Flange 10K / JIS B2238 PVF 5*H**-J*********** Sensor Fits to M K H x B N Flange B to 8 N x 42 M 15 N x 42 K 25 (IN) N x 52 Fitting length = (2 x ) + 86 mm The requisite ground rings can be ordered as accessories (Order No. K5HR-****) F06-xxHxxxxx xx Endress+Hauser

29 External pipe thread ISO 228 / IN / 316 SS 5*H**-K*********** S Sensor Fits to S H x B Internal thread inches in (mm) inches in (mm) in (mm) inches 1/12" to 5/16" R 3/8" 0.39 (10) 3/8" 1.57 (40) 0.40 (10.1) 2.36 x /2" R 1/2" 0.63 (16) 1/2" 1.57 (40) 0.52 (13.2) 2.36 x " R 1" 0.98 (25) 1" 1.65 (42) 0.65 (16.5) 2.76 x 2.05 Fitting length = (2 x ) " (86 mm) F06 H Internal pipe thread ISO 228 / IN 2999, / 316 SS 5*H**-*********** S Sensor Fits to S H x B External thread inches in (mm) inches in (mm) in (mm) in (mm) inches 1/12" to 5/16" Rp 3/8" 0.35 (9.0) 3/8" 0.87 (22) 1.77 (45) 0.51 (13) 2.36 x /2" Rp 1/2" 0.63 (16.0) 1/2" 1.06 (27) 1.77 (45) 0.55 (14) 2.36 x " Rp 1" 1.07 (27.2) 1" 1.57 (40) 2.01 (51) 0.67 (17) 2.76 x 2.05 Fitting length = (2 x ) " (86 mm) F06-xxHxxxxx xx-027 Hose connection / 316 SS 5*H**-M/N/P*********** Sensor Fits to W H x B Inside ameter in (mm) in (mm) in (mm) in (mm) inches 1/12" to 5/16" 0.51 (13) 0.39 (10.0) 0.51 (13) 1.93 (49) 2.36 x /2" 0.63 (16) 0.50 (12.6) 0.63 (16) 1.93 (49) 2.36 x /2" 0.75 (19) 0.63 (16.0) 0.75 (19) 1.93 (49) 2.36 x 1.65 Fitting length = (2 x ) " (86 mm) F06-xxHxxxxx xx-024 Adhesive fitting PVC 5*H**-R/S*********** Sensor Fits to H x B pipe (mm) (mm) (mm) (mm) 1/12" to 5/16" 1/2" 0.85" (21.5) 1.07" (27.3) 1.52" (38.5) 2.36" x 1.65" N 2 to 8 N x 2 (IN 8062) 20 x 2 (IN 8062) (20.2) (27.0) (38.5) (60 x 42) (20.2) (27.0) (28.0) (60 x 42) Fitting length = (2 x ) " (86 mm) The requisite ground rings can be ordered as accessories (Order No. K5HR-****) F06-xxHxxxxx xx-028 Endress+Hauser 29

30 Process connections with aseptic gasket seal 1/12" to 1" (N 2 to 25 ) Weld nipple for IN / 316 SS 5*H**-U*********** Sensor Fits to H x B N (mm) Piping IN (mm) (mm) (mm) (mm) 2 to 8 14 x x x x (IN) 30 x x 52 Fitting length = (2 x ) + 86 mm If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 22) and process connection () into account. A Weld nipples for OT/SMS / 316 SS 5*H**-V*********** Sensor Fits to H x B Piping O/SMS in (mm) in (mm) in (mm) inches 1/12" to 5/16" 1/2" 0.35 (9.0) 0.50 (12.7) 0.63 (16.1) 2.36 x /2" 3/4" 0.63 (16.0) 0.75 (19.1) 0.63 (16.1) 2.36 x " 1" 0.89 (22.6) 1.0 (25.4) 0.63 (16.1) 2.76 x 2.05 Fitting length = (2 x ) " (86 mm) If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 22) and process connection () into account. A Clamp ISO 2852, Fig / 316 SS 5*H**-W*********** Sensor Fits to Clamp ISO 2852 H x B Piping ISO 2037 / BS iameter in (mm) in (mm) in (mm) in (mm) inches 1" Tube 1" x 0.64" 0.98 (25) 0.89 (22.6) 1.99 (50.5) 1.74 (44.3) 2.76 x 2.05 Fitting length = (2 x ) " (86 mm) If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 22) and process connection () into account. F06 xxhxxxxx xx 023 Clamp IN / 316 SS 5*H**-0*********** Sensor Fits to H x B N Piping IN to 8 Tube 14 x 2 (N 10) x Tube 20 x 2 (N 15) x (IN) Tube 30 x 2 (N 25) x 52 Fitting length = (2 x ) + 86 mm If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 22) and process connection () into account. F06-xxHxxxxx xx Endress+Hauser

31 Tri-clamp 14 AM / 316 SS 5*H**-1*********** Sensor Fits to H x B Piping O in (mm) in (mm) in (mm) inches 1/12" to 5/16" Tube 12.7 x 1.65 (OT 1/2") 0.37 (9.4) 0.98 (25) (28.5) 2.36 x /2" Tube 19.1 x 1.65 (OT 3/4") 1" Tube 25.5 x 1.65 (OT 1") 0.62 (15.8) 0.98 (25) (28.5) 2.36 x (22.1) 1.98 (50.4) 1.12 (28.5) 2.76 x 2.05 A Fitting length = (2 x ) " (86 mm) If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 22) and process connection () into account. Coupling SC IN Threaded adapter / 316 SS 5*H**-2*********** Sensor Fits to H x B N Piping IN to 8 Tube 12 x 1 (N 10) 10 Rd 28 x 1/8" x Tube 18 x 1 or 1.5 (N 15) 25 (IN) Tube 28 x 1 or 1.5 (N 25) 16 Rd 34 x 1/8" x Rd 52 x 1/6" x 52 F06-xxHxxxxx xx-017 Fitting length = (2 x ) + 86 mm If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 22) and process connection () into account. Coupling IN Aseptic threaded adapter, Form A / 316 SS 5*H**-3*********** Sensor Fits to H x B N Piping IN to 8 Tube 13 x 1.5 (N 10) 10 Rd 28 x 1/8" x Tune 19 x 1.5 (N 15) 16 Rd 34 x 1/8" x (IN) Tube 29 x 1.5 (N 25) 26 Rd 52 x 1/6" x 52 Fitting length = (2 x ) + 86 mm If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 22) and process connection () into account. F06-xxHxxxxx xx-021 Flange IN Aseptic grooved flange, Form A / 316 SS 5*H**-4*********** M Sensor Fits to K M H x B N Piping IN to 8 Tube 13 x 1.5 (N 10) x 42 K 15 Tube 19 x 1.5 (N 15) x (IN) Tube 29 x 1.5 (N 25) x 52 Fitting length = (2 x ) + 86 mm If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 22) and process connection () into account. F06-xxHxxxxx xx-022 Endress+Hauser 31

32 Coupling SMS 1145 Threaded adapter / 316 SS 5*H**-5*********** Sensor Fits to SMS 1145 H x B N Piping O iameter 25 (1" ANSI) 1" Rd 40 x 1/6" x 52 Fitting length = (2 x ) + 86 mm If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 22) and process connection () into account. F06-xxHxxxxx-06- Process connections ordered only as accessories (with O-ring seal, 1/12" to 1" / N 2 to 25) External pipe thread / 316 SS KH**-** Sensor Fits to S H x B N NP internal thread [inch] 2 to 8 NPT 3/8" 10 3/8" x 42 S 15 NPT 1/2" 16 1/2" x (1" ANSI) NPT 1" 25 1" x 52 Fitting length = (2 x ) + 86 mm F06-xxHxxxxx xx-025 Internal pipe thread / 316 SS KH**-C** S Sensor Fits to NPT S H x B external thread in (mm) inches in (mm) in (mm) in (mm) inches 1/12" to 5/16" NPT 3/8" 0.35 (8.9) 3/8" 0.87 (22) 1.77 (45) 0.51 (13) 2.36 x /2" NPT 1/2" 0.63 (16.0) 1/2" 1.06 (27) 1.77 (45) 0.55 (14) 2.36 x " ANSI NPT 1" 1.07 (27.2) 1" 1.57 (40) 2.01 (51) 0.67 (17) 2.76 x 2.05 Fitting length = (2 x ) " (86 mm) F06-xxHxxxxx xx Endress+Hauser

33 Process connections orderable only as accessories (with aseptic gasket seal) Tri-Clamp 14 AM / 316 SS KH**-HF*** Sensor Fits to H x B Piping O in (mm) in (mm) in (mm) in (mm) 1/2 (N 15) Tube 25.4 x 1.5 (OT; 1") 0.87 (22.1) 1.98 (50.4) 1.12 (28.5) 2.36 x 1.65 (60 x 42) Fitting length = (2 x ) " (86 mm) If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 22) and process connection () into account. F06-xxHxxxxx-06- round rings (accessories for PVF flanges / PVC adhesive fitting) round ring /316 SS, Alloy C-22, tantalum K5HR **** Sensor B C in (mm) in (mm) in (mm) in (mm) 1/12" to 5/16" 0.35 (9.0) 1.33 (33.9) 0.87 (22.0) 0.69 (17.6) 1/2" 0.63 (16.0) 1.33 (33.9) 1.14 (29.0) 0.97 (24.6) 1" 0.89 (22.6) 1.73 (43.9) 1.44 (36.5) 1.23 (31.2) 0.14" (3.5) Æ B Æ C Æ Æ 0.02" (0.5) 25 (IN) 1.02 (26.0) 1.73 (43.9) 1.53 (39.0) 1.36 (34.6) 0.07" (1.9) 0.13" (3.4) 0.17" (4.5) Endress+Hauser 33

34 Front view 1-1/2" to 4" (N 40 to 100), without process connection K Z Z-Z 90 ±0.5 E C B A Z 60 ±0.5 H F F06-5xHxxxxx xx-001 Nominal size A B C E F H K in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) Thread holes 1-1/2 (40) 4.80 (122.0) 3.39 (86) 2.79 (71.0) 2.01 (51.0) 1.39 (35.3) M (15) 0.71 (18) 4 2 (50) 5.79 (147.0) 3.90 (99) 3.29 (83.5) 2.50 (63.5) 1.89 (48.1) M (15) 0.71 (18) 4 2-1/2 (65) 5.79 (147.0) 4.53 (115) 3.94 (100.0) 2.99 (76.1) 2.36 (59.9) M (15) 0.71 (18) 6 3 (80) 7.76 (197.0) 5.55 (141) 4.76 (121.0) 3.50 (88.9) 2.86 (72.6) M (15) 0.79 (20) 4 4 (100) 7.76 (197.0) 6.38 (162) 5.57 (141.5) 4.50 (114.3) 3.84 (97.5) M (15) 0.79 (20) 6 34 Endress+Hauser

35 Process connections with gasket seal, 1-1/2" to 4"(N 40 to 100) Weld nipples for IN / 316 SS 5*H**-U*********** Sensor N Fits to Piping IN K x x K x x x Fitting length = (2 x ) mm (N 40 65) / mm (N ) If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 24) and process connection () into account. Weld nipples for OT/SMS / 316 SS 5*H**-V*********** Sensor N (mm) Fits to Piping O/SMS (mm) (mm) (mm) (mm) (mm) 1 (mm) K (mm) x x K x x x Fitting length = (2 x ) mm (N 40 65) / mm (N ) If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 24) and process connection () into account. Clamp ISO / 316 SS 5*H**-W*********** Sensor size Fits to Piping ISO 2037 / BS Clamp ISO 2852 iameter in (mm) in (mm) in (mm) in (mm) K inches K 1-1/2" 1.50" 1.5" 1.40 (35.6) 1.99 (50.5) 3.62 (92) 2.70 (68.5) " 2.00" 2" 1.91 (48.6) 2.52 (64.0) 4.13 (105) 2.70 (68.5) /2" 2.50" 2.5" 2.37 (60.3) 3.05 (77.5) 4.76 (121) 2.70 (68.5) " 3.00" 3" 2.87 (72.9) 3.58 (91.0) 5.79 (147) 2.70 (68.5) " 4.00" 4" 3.84 (97.6) 4.69 (119.0) 6.61 (168) 2.70 (68.5) 5.57 Fitting length = (2 x ) " (1-1/2" to 2-/12"), " (3" to 4") If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 24) and process connection () into account. Clamp IN / 316 SS 5*H**-0*********** Sensor N Fits to Piping IN K x x K x x F06-xxHxxxxx-06- F06-xxHxxxxx-06- F06-xxHxxxxx F06-xxHxxxxx x Fitting length = (2 x ) mm (N 40 65) / mm (N ) If pigs are used for cleaning, it is essential to take the inside ameters of measuring tube (Page 24) and process connection () into account. Endress+Hauser 35

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H Technical Information TI 051D/06/en 50097004 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H Flow measurement in hygiene, food and beverage or process applications Features

More information

Proline Promag 55H. Technical Information

Proline Promag 55H. Technical Information Technical Information Proline Promag 55H Electromagnetic Flow Measuring System Flow measurement of liquids with solids content or inhomogeneous liquids in hygienic, food or process applications Application

More information

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Technical Information TI 049D/06/en 50097005 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Flow rate measurement in chemical or process applications Features and benefits

More information

Proline Promag 50H, 53H

Proline Promag 50H, 53H Technical Information Proline Promag 50H, 53H Electromagnetic Flow Measuring System Flow measurement of liquids in hygienic, food or process applications Application Electromagnetic flowmeter for birectional

More information

Technical Information Proline Promag 50H, 53H

Technical Information Proline Promag 50H, 53H TI00048D/06/EN/15.17 71364351 Products Solutions Services Technical Information Proline Promag 50H, 53H Electromagnetic flowmeter The flowmeter for smallest flow rates with a modular electronic concept

More information

Proline Promag 55H. Technical Information

Proline Promag 55H. Technical Information Technical Information Proline Promag 55H Electromagnetic Flow Measuring System Flow rate measurement of liquids with solids content or inhomogeneous liquids in hygiene, food and beverage or process applications

More information

Proline Promag 50W, 53W

Proline Promag 50W, 53W Technical Information Proline Promag 50W, 53W Electromagnetic Flow Measuring System Flow measurement in water or wastewater applications Application Electromagnetic flowmeter for bidirectional measurement

More information

Technical Information Proline Promag 10P

Technical Information Proline Promag 10P TI00094D/06/EN/13.17 71385977 Products Solutions Services Technical Information Electromagnetic flowmeter Flow measurement of liquids in chemical or process applications Application Electromagnetic flowmeter

More information

Proline Promag 10H. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in hygienic, food or process applications

Proline Promag 10H. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in hygienic, food or process applications Technical Information Proline Promag 1H Electromagnetic Flow Measuring System Flow measurement of liquids in hygienic, food or process applications Application Electromagnetic flowmeter for birectional

More information

Proline Promag 55S. Technical Information

Proline Promag 55S. Technical Information Technical Information Proline Promag 55S Electromagnetic Flow Measuring System Flow rate measurement of liquids with solids content or inhomogeneous liquids Application Electromagnetic flowmeter for bidirectional

More information

Proline Promag 50P, 53P

Proline Promag 50P, 53P Technical Information Proline Promag 50P, 53P Electromagnetic Flow Measuring System Flow rate measurement in chemical or process applications Application Electromagnetic flowmeter for bidirectional measurement

More information

Technical Information Proline Promag 55S

Technical Information Proline Promag 55S TI00071D/06/EN/14.17 71385973 Products Solutions Services Technical Information Electromagnetic flowmeter The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics Application

More information

Proline Promag 55S. Technical Information

Proline Promag 55S. Technical Information Technical Information Proline Promag 55S Electromagnetic Flow Measuring System Flow rate measurement of liquids with solids content or inhomogeneous liquids Application Electromagnetic flowmeter for bidirectional

More information

Proline Promag H 200. Technical Information

Proline Promag H 200. Technical Information Technical Information Electromagnetic flow measuring system The device with genuine two-wire technology and for minimal flow rates Application Accurate birectional measurement of liquids with a minimum

More information

Proline Promag 10P. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in chemical or process applications

Proline Promag 10P. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in chemical or process applications Technical Information Proline Promag 10P Electromagnetic Flow Measuring System Flow measurement of liquids in chemical or process applications Application Electromagnetic flowmeter for bidirectional measurement

More information

Proline Promag 23H. Technical Information

Proline Promag 23H. Technical Information Technical Information Proline Promag 23H Electromagnetic Flow Measuring System Two-wire technology Flow measurement of liquids in hygienic, food or process applications Application Electromagnetic flowmeter

More information

Proline Promag 50W, 53W

Proline Promag 50W, 53W Technical Information Proline Promag 50W, 53W Electromagnetic Flow Measuring System Flow measurement in water or wastewater applications Application Electromagnetic flowmeter for bidirectional measurement

More information

Technical Information Proline Promag 53E

Technical Information Proline Promag 53E TI01164D/06/EN/01.14 71249512 Products Solutions Services Technical Information Electromagnetic flowmeter The economical flowmeter with flexible system integration Application The measuring principle is

More information

Electromagnetic Flow Measuring System promag 33

Electromagnetic Flow Measuring System promag 33 Technical Information TI 07D/06/en No. 50063743 Electromagnetic Flow Measuring System promag 33 Flexible System Wide choice of materials for process connections and measuring tube linings, compatible to

More information

Technical Information Proline Promag 10D

Technical Information Proline Promag 10D TI00081D/06/EN/14.16 71314546 Products Solutions Services Technical Information Proline Promag 10D Electromagnetic flowmeter The highly cost-effective flowmeter, available as compact wafer Application

More information

Proline Promag 10W. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications

Proline Promag 10W. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications Technical Information Proline Promag 10W Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications Application Electromagnetic flowmeter for bidirectional measurement

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Promag 55S. Technical Information. Electromagnetic Flow Measuring System Flow rate measurement of liquids with solids content or inhomogeneous liquids

Promag 55S. Technical Information. Electromagnetic Flow Measuring System Flow rate measurement of liquids with solids content or inhomogeneous liquids Technical Information Promag 55S Electromagnetic Flow Measuring System Flow rate measurement of liquids with solids content or inhomogeneous liquids Application Electromagnetic flowmeter for bidirectional

More information

Coriolis Mass Flow Measuring System promass 40 E

Coriolis Mass Flow Measuring System promass 40 E Technical Information TI 055D/06/en 50098284 Coriolis Mass Flow Measuring System promass 40 E The new mass flow measuring system with low cost and basic functionality the economical alternative to conventional

More information

Technical Information Proline Promag H 100

Technical Information Proline Promag H 100 TI01101D/06/EN/02.13 71233383 Products Solutions Services Technical Information Proline Promag H 100 Electromagnetic flowmeter The flowmeter for smallest flow rates with an ultra-compact transmitter Application

More information

Proline Promag 10D. Technical Information. Electromagnetic flow measuring system Flow measurement of liquids in water or wastewater applications

Proline Promag 10D. Technical Information. Electromagnetic flow measuring system Flow measurement of liquids in water or wastewater applications Technical Information Electromagnetic flow measuring system Flow measurement of liquids in water or wastewater applications Application Electromagnetic flowmeter for bidirectional measurement of liquids

More information

Proline Promass 40E. Technical Information

Proline Promass 40E. Technical Information Technical Information Coriolis Mass Flow Measuring System The mass flow measuring system with low cost and basic functionality. The economical alternative to conventional volume flowmeters. Application

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Electromagnetic Flow Measuring System promag 35

Electromagnetic Flow Measuring System promag 35 Technical Information TI 035D/06/en No. 50075884 Electromagnetic Flow Measuring System promag 35 Applications Promag 35 S solves complex flow problems and is used to measure fluids with a high solids content,

More information

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring

More information

Technical Information Proline Promag L 400

Technical Information Proline Promag L 400 TI01045D/06/EN/06.16 71314353 Products Solutions Services Technical Information Proline Promag L 400 Electromagnetic flowmeter The flowmeter with an integrated web server and weight-optimized sensor Application

More information

Proline Promag 50D. Technical Information. Electromagnetic flow measuring system Flow measurement of liquids in water or wastewater applications

Proline Promag 50D. Technical Information. Electromagnetic flow measuring system Flow measurement of liquids in water or wastewater applications Technical Information Electromagnetic flow measuring system Flow measurement of liquids in water or wastewater applications Application Electromagnetic flowmeter for bidirectional measurement of liquids

More information

Proline Promass 80/83 H, I

Proline Promass 80/83 H, I Technical Information Proline Promass 80/83 H, I Coriolis Mass Flow Measuring System The single-tube system with a fit-and-forget design: easy to clean hygienic does not harm the material being measured

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Technical Information Proline Promag W 400

Technical Information Proline Promag W 400 TI01046D/06/EN/05.15 71280405 Products Solutions Services Technical Information Proline Promag W 400 Electromagnetic flowmeter The flowmeter with integrated web server & sensor with EN ISO 12944 corrosion

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

Technical Information Proline Promag W 800

Technical Information Proline Promag W 800 TI00117D/06/EN/02.13 71225832 Products Solutions Services Technical Information Proline Promag W 800 Electromagnetic flowmeter Certified corrosion protection and intelligent energy efficient mode Application

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

Proline Promass 40E. Technical Information

Proline Promass 40E. Technical Information Technical Information Proline Promass 40E Coriolis Mass Flow Measuring System The mass flow measuring system with low cost and basic functionality. The economical alternative to conventional volume flowmeters.

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

Technical Information Proline Promag W 800

Technical Information Proline Promag W 800 TI00117D/06/EN/03.14 71245159 Products Solutions Services Technical Information Proline Promag W 800 Electromagnetic flowmeter Battery powered flowmeter with EN ISO 12944 corrosion protection & intelligent

More information

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive flow Meter fmi 1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Proline Promass 80I, 83I

Proline Promass 80I, 83I Technical Information Proline Promass 80I, 83I Coriolis Mass Flow Measuring System The single-tube system with a "fit-and-forget" design: In-line viscosity measurement easy to clean hygienic does not harm

More information

Proline Promass 80H, 83H

Proline Promass 80H, 83H Technical Information Proline Promass 80H, 83H Coriolis Mass Flow Measuring System The single-tube system with a "fit-and-forget" design: does not harm the material being measured chemical-resistant materials

More information

Brief Operating Instructions Proline Promag 50

Brief Operating Instructions Proline Promag 50 KA0006D/06/EN/8.6 73439 Products Solutions Services Brief Operating Instructions Proline Promag 50 Electromagnetic flowmeter These Brief Operating Instructions are not intended to replace the Operating

More information

Level Limit Switch nivotester FTL 325 P

Level Limit Switch nivotester FTL 325 P Technical Information TI 350F/24/ae Level Limit Switch nivotester FTL 325 P With intrinsically safe signal circuit for connection to the Liquiphant and Soliphant measuring sensor Application Level limit

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Condumax W CLS15 and CLS15D

Condumax W CLS15 and CLS15D Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

Proline Promass 80I, 83I

Proline Promass 80I, 83I Technical Information Proline Promass 80I, 83I Coriolis Mass Flow Measuring System The single-tube system with a "fit-and-forget" design: easy to clean hygienic does not harm the material being measured

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

Proline Promass 80E, 83E

Proline Promass 80E, 83E Technical Information Proline Promass 80E, 83E Coriolis Mass Flow Measuring System Mass flow measuring system offering "Low Cost of Ownership" as an alternative to conventional volumetric flowmeters Application

More information

Technical Information Condumax CLS15D/CLS15

Technical Information Condumax CLS15D/CLS15 TI0009C/07/EN/4.4 7268306 Products Solutions Services Technical Information Condumax CLS5D/CLS5 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 0.0 cm or k = 0. cm Application

More information

Indumax CLS50/CLS50D. Technical Information

Indumax CLS50/CLS50D. Technical Information Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D

More information

Proline Promass 83E. Coriolis Mass Flowmeter. Specifications. The Most Trusted Name In Measurement. Issue/Rev. 0.0 (8/11) Bulletin SS0M029

Proline Promass 83E. Coriolis Mass Flowmeter. Specifications. The Most Trusted Name In Measurement. Issue/Rev. 0.0 (8/11) Bulletin SS0M029 Coriolis Mass Flowmeter Proline Promass 83E Specifications Issue/Rev. 0.0 (8/11) Bulletin SS0M029 Applications The Coriolis measuring principle operates independently of the physical fluid properties,

More information

Technical Information Proline Promass 80E, 83E

Technical Information Proline Promass 80E, 83E TI61D/6/EN/15.15 71281945 Products Solutions Services Technical Information Proline Promass 8E, 83E Coriolis flowmeter The flowmeter for minimized cost of ownership with extended transmitter functionality

More information

Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P

Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P Technical Information TI 056D/24/ae Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P Volume flow measurement of liquids in chemical or process applications Features and benefits

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only

More information

Proline Promag 50. Operating Instructions. Electromagnetic Flow Measuring System

Proline Promag 50. Operating Instructions. Electromagnetic Flow Measuring System Operating Instructions Proline Promag 50 Electromagnetic Flow Measuring System 6 BA046D/06/en/03.05 50097090 Valid as of version: V 2.00.XX (Device software) Brief operating instructions Proline Promag

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

Proline Promass 40E. Technical Information

Proline Promass 40E. Technical Information Technical Information Proline Promass 40E Coriolis Mass Flow Measuring System The mass flow measuring system with low cost and basic functionality. The economical alternative to conventional volume flowmeters.

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring

More information

OPTIFLUX 1000 Technical Datasheet

OPTIFLUX 1000 Technical Datasheet OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

Proline Promass 80A, 83A

Proline Promass 80A, 83A Technical Information Proline Promass 80A, 83A Coriolis Mass Flow Measuring System The single-tube system for highly accurate measurement of very small flows Application The Coriolis measuring principle

More information

Proline Promass 80S, 83S

Proline Promass 80S, 83S Technical Information Proline Promass 80S, 83S Coriolis Mass Flow Measuring System The single-tube system with a "fit-and-forget" design: Easy to clean hygienic drainable does not harm the material being

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Technical Information Proline Promass 80F, 83F

Technical Information Proline Promass 80F, 83F TI11D/6/EN/13.14 7123133 Products Solutions Services Technical Information Proline Promass 8F, 83F Coriolis flowmeter The flowmeter with premium accuracy and robustness with a compact or remote transmitter

More information

JUMO flowtrans MAG S01

JUMO flowtrans MAG S01 Phone: +49 661 6003-0 Fax: +49 661 6003-607 Internet: www.jumo.net Fax: +44 1279 635262 sales@jumo.co.uk Fax: 315-437-5860 info.us@jumo.net Page 1/57 JUMO flowtrans MAG S01 Electromagnetic flowmeter for

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/01.12 71195835 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application The compact measuring

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

Technical Information Dosimag

Technical Information Dosimag TI00066D/06/EN/3. 725587 Products Solutions Services Technical Information Dosimag Electromagnetic flowmeter Flowmeter with maximum repeatability and ultra-compact sensor with hygienic design Application

More information

JUMO flowtrans MAG H01

JUMO flowtrans MAG H01 sales@jumo.co.uk info.us@jumo.net Page 1/50 JUMO flowtrans MAG H01 Electromagnetic flowmeter for hygienic applications Brief description The electromagnetic flowmeter JUMO flowtrans MAG H01 was specially

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Technical Information Condumax CLS21D/CLS21

Technical Information Condumax CLS21D/CLS21 TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Dosimass. Technical Information. Coriolis Mass Flow Measuring System For filling applications

Dosimass. Technical Information. Coriolis Mass Flow Measuring System For filling applications Technical Information Coriolis Mass Flow Measuring System For filling applications Application Suitable for use as a mass or volume flowmeter for filling applications. Liquids with the most diverse properties

More information

Radar Level Measurement micropilot FMR 130 for stilling wells

Radar Level Measurement micropilot FMR 130 for stilling wells Technical Information TI 258F/24/ae Radar Level Measurement micropilot FMR 130 for stilling wells Smart transmitter for non-contact measurement in metallic by-pass pipes and stilling wells Suitable for

More information

IFC 100 Technical Datasheet

IFC 100 Technical Datasheet IFC 100 Technical Datasheet Signal converter for electromagnetic flowmeters Simple and easy to install and start-up Diagnostics of device and application Extremely fast signal conversion The documentation

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. HygienicMaster FEH630 Electromagnetic flowmeter

ABB MEASUREMENT & ANALYTICS DATA SHEET. HygienicMaster FEH630 Electromagnetic flowmeter ABB MEASUREMENT & ANALYTICS DATA SHEET HygienicMaster FEH630 Electromagnetic flowmeter 2 HYGIENICMASTER FEH630 ELECTROMAGNETIC FLOWMETER DS/FEH630-EN REV. C Measurement made easy The clean choice for all

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as

More information

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

Coriolis Mass Flow Measuring System PROline promass 80/83 E

Coriolis Mass Flow Measuring System PROline promass 80/83 E Technical Information TI061D/06/en 50102807 Coriolis Mass Flow Measuring System PROline promass 80/83 E Mass flow measuring system offering Low Cost of Ownership as an alternative to conventional volumetric

More information

IFC 050 Technical Datasheet

IFC 050 Technical Datasheet IFC 050 Technical Datasheet Signal converter for electromagnetic flowmeters For water and wastewater applications Multiple outputs, incl. active pulse output and RS485 Modbus Excellent price/performance

More information