Licence Number 011-7S321 R Annex to Solar Keymark Certificate - Date issued Summary of EN ISO 9806:2013 Test Results Issued by
|
|
- Walter Singleton
- 6 years ago
- Views:
Transcription
1 Licence Number 011-7S321 R Annex to Solar Keymark Certificate - Date issued Summary of EN ISO 9806:2013 Test Results Issued by DIN CERTCO Licence holder Wolf GmbH Deutschland Brand (optional) Street, Number Postcode, City Industriestraße Mainburg Country Web Tel Michael.Klepmeir@wolf.eu Page 1/6 Collector Type CRK-6 Evacuated tubular collector Power output per collector Gb = 850 W/m²; Gd = 150 W/m² ϑm - ϑa 0 K 10 K 30 K 50 K 70 K 104 K m² mm mm mm W W W W W W area (A G ) length width height Power output per m² gross area Performance parameters test method Performance parameters (related to AG) Units Test results Incidence angle modifier test method Bi-directional incidence angle modifiers Incidence angle modifier Transversal Longitudinal Steady state - outdoor η0,hem a1 a2 - W/(m²K) W/(m²K²) Quasi dynamic - outdoor Yes Angle K θt,coll K θl,coll Heat transfer medium for testing Flow rate for testing (per gross area, A G ) Water dm/dt kg/(sm²) Maximum temperature difference for thermal performance calculations Standard stagnation temperature (G = 1000 W/m²; ϑ a = 30 ) Effective thermal capacity, incl. fluid (per gross area, A G ) Maximum operating temperature Maximum operating pressure (ϑ m -ϑ a ) max ϑ stg C/m 2 ϑ max_op p max,op K kj/(km 2 ) kpa Testing laboratory TZS, ITW University Stuttgart Test report(s) 14COL1031OEM06 Dated COL1032Q/1OEM COL456/ Comments of testing laboratory Datasheet version: 5.01, Data sheet based on results of test report 06COL456/7 Stamp & signature of test lab
2 Page 2/6 Annex to Solar Keymark Certificate Licence Number 011-7S321 R Supplementary Information Issued Annual collector output in kwh/collector at mean fluid temperature ϑ m, based on ISO 9806:2013 test results CRK-6 Standard Locations Athens Davos Stockholm Würzburg ϑ m Annual output per m² gross area Fixed or tracking collector Fixed (slope = latitude - 15 ; rounded to nearest 5 ) Annual irradiation on collector plane 1765 kwh/m² 1714 kwh/m² 1166 kwh/m² 1244 kwh/m² Mean annual ambient air temperature Collector orientation or tracking mode South, 25 South, 30 South, 45 South, 35 The collector is operated at constant temperature ϑm (mean of in- and outlet temperatures). The calculation of the annual collector performance is performed with the official Solar Keymark spreadsheet tool Scenocalc Ver (March 2016). A detailed description of the calculations is available at Additional Information Collector heat transfer medium Water-Glycole Hybrid Thermal and Photo Voltaic collector The collector is deemed to be suitable for roof integration The collector was tested successfully according to EN ISO 9806:2013 under the following conditions: Climate class (A, B or C) A -- Maximum tested positive load 2400 Pa Maximum tested negative load 3000 Pa Hail resistance using ice balls (diameter) 35 mm Energy Labelling Information Reference Area, A sol (m 2 ) Data required for CDR (EU) 811/ Reference Area A sol CRK Collector efficiency (η col ) 52 % Remark: Collector efficiency (η col ) is defined in CDR (EU) 811/2013 as collector efficiency of the solar collector at a temperature difference between the solar collector and the surrounding air of 40 K and a global solar irradiance of 1000 W/m², expressed in % and rounded to the nearest integer. Deviating from the regulation η col is based on reference area (A sol ) which is aperture area for values according to EN or gross area for ISO 9806:2013. Data required for CDR (EU) 812/ Reference Area A sol Zero-loss efficiency (η 0 ) First-order coefficient (a 1 ) 0.65 W/(m²K) Second-order coefficient (a 2 ) W/(m²K²) Incidence angle modifier IAM (50 ) Remark: The data given in this section are related to collector reference area (A sol ) which is aperture area for values according to EN or gross area for ISO Consistent data sets for either aperture or gross area can be used in calculations like in the regulation 811 and 812 and simulation programs.
3 Licence Number 011-7S321 R Annex to Solar Keymark Certificate - Date issued Summary of EN ISO 9806:2013 Test Results Issued by DIN CERTCO Licence holder Wolf GmbH Deutschland Brand (optional) Street, Number Postcode, City Industriestraße Mainburg Country Web Tel Michael.Klepmeir@wolf.eu Page 3/6 Collector Type CRK-12 Evacuated tubular collector Power output per collector Gb = 850 W/m²; Gd = 150 W/m² ϑm - ϑa 0 K 10 K 30 K 50 K 70 K 104 K m² mm mm mm W W W W W W area (A G ) length width height Power output per m² gross area Performance parameters test method Performance parameters (related to AG) Units Test results Incidence angle modifier test method Bi-directional incidence angle modifiers Incidence angle modifier Transversal Longitudinal Steady state - outdoor η0,hem a1 a2 - W/(m²K) W/(m²K²) Quasi dynamic - outdoor Yes Angle K θt,coll K θl,coll Heat transfer medium for testing Flow rate for testing (per gross area, A G ) Water dm/dt kg/(sm²) Maximum temperature difference for thermal performance calculations Standard stagnation temperature (G = 1000 W/m²; ϑ a = 30 ) Effective thermal capacity, incl. fluid (per gross area, A G ) Maximum operating temperature Maximum operating pressure (ϑ m -ϑ a ) max ϑ stg C/m 2 ϑ max_op p max,op K kj/(km 2 ) kpa Testing laboratory TZS, ITW University Stuttgart Test report(s) 14COL1031OEMOEM06 Dated COL1032Q/1OEM COL456/ Comments of testing laboratory Datasheet version: 5.01, Data sheet based on results of test report 06COL456/7 Stamp & signature of test lab
4 Page 4/6 Annex to Solar Keymark Certificate Licence Number 011-7S321 R Supplementary Information Issued Annual collector output in kwh/collector at mean fluid temperature ϑ m, based on ISO 9806:2013 test results CRK-12 Standard Locations Athens Davos Stockholm Würzburg ϑ m Annual output per m² gross area Fixed or tracking collector Fixed (slope = latitude - 15 ; rounded to nearest 5 ) Annual irradiation on collector plane 1765 kwh/m² 1714 kwh/m² 1166 kwh/m² 1244 kwh/m² Mean annual ambient air temperature Collector orientation or tracking mode South, 25 South, 30 South, 45 South, 35 The collector is operated at constant temperature ϑm (mean of in- and outlet temperatures). The calculation of the annual collector performance is performed with the official Solar Keymark spreadsheet tool Scenocalc Ver (March 2016). A detailed description of the calculations is available at Additional Information Collector heat transfer medium Water-Glycole Hybrid Thermal and Photo Voltaic collector The collector is deemed to be suitable for roof integration The collector was tested successfully according to EN ISO 9806:2013 under the following conditions: Climate class (A, B or C) A -- Maximum tested positive load 2400 Pa Maximum tested negative load 3000 Pa Hail resistance using ice balls (diameter) 35 mm Energy Labelling Information Reference Area, A sol (m 2 ) Data required for CDR (EU) 811/ Reference Area A sol CRK Collector efficiency (η col ) 53 % Remark: Collector efficiency (η col ) is defined in CDR (EU) 811/2013 as collector efficiency of the solar collector at a temperature difference between the solar collector and the surrounding air of 40 K and a global solar irradiance of 1000 W/m², expressed in % and rounded to the nearest integer. Deviating from the regulation η col is based on reference area (A sol ) which is aperture area for values according to EN or gross area for ISO 9806:2013. Data required for CDR (EU) 812/ Reference Area A sol Zero-loss efficiency (η 0 ) First-order coefficient (a 1 ) 0.65 W/(m²K) Second-order coefficient (a 2 ) W/(m²K²) Incidence angle modifier IAM (50 ) Remark: The data given in this section are related to collector reference area (A sol ) which is aperture area for values according to EN or gross area for ISO Consistent data sets for either aperture or gross area can be used in calculations like in the regulation 811 and 812 and simulation programs.
5 Licence Number 011-7S321 R Annex to Solar Keymark Certificate - Date issued Summary of EN ISO 9806:2013 Test Results Issued by DIN CERTCO Licence holder Wolf GmbH Deutschland Brand (optional) Street, Number Postcode, City Industriestraße Mainburg Country Web Tel Michael.Klepmeir@wolf.eu Page 5/6 Collector Type CRK-18 Evacuated tubular collector Power output per collector Gb = 850 W/m²; Gd = 150 W/m² ϑm - ϑa 0 K 10 K 30 K 50 K 70 K 104 K m² mm mm mm W W W W W W area (A G ) length width height Power output per m² gross area Performance parameters test method Performance parameters (related to AG) Units Test results Incidence angle modifier test method Bi-directional incidence angle modifiers Incidence angle modifier Transversal Longitudinal Steady state - outdoor η0,hem a1 a2 - W/(m²K) W/(m²K²) Quasi dynamic - outdoor Yes Angle K θt,coll K θl,coll Heat transfer medium for testing Flow rate for testing (per gross area, A G ) Water dm/dt kg/(sm²) Maximum temperature difference for thermal performance calculations Standard stagnation temperature (G = 1000 W/m²; ϑ a = 30 ) Effective thermal capacity, incl. fluid (per gross area, A G ) Maximum operating temperature Maximum operating pressure (ϑ m -ϑ a ) max ϑ stg C/m 2 ϑ max_op p max,op K kj/(km 2 ) kpa Testing laboratory TZS, ITW University Stuttgart Test report(s) 14COL1031OEM06 Dated COL1032Q/1OEM COL456/ Comments of testing laboratory Datasheet version: 5.01, Data sheet based on results of test report 06COL456/7 Stamp & signature of test lab
6 Page 6/6 Annex to Solar Keymark Certificate Licence Number 011-7S321 R Supplementary Information Issued Annual collector output in kwh/collector at mean fluid temperature ϑ m, based on ISO 9806:2013 test results CRK-18 Standard Locations Athens Davos Stockholm Würzburg ϑ m Annual output per m² gross area Fixed or tracking collector Fixed (slope = latitude - 15 ; rounded to nearest 5 ) Annual irradiation on collector plane 1765 kwh/m² 1714 kwh/m² 1166 kwh/m² 1244 kwh/m² Mean annual ambient air temperature Collector orientation or tracking mode South, 25 South, 30 South, 45 South, 35 The collector is operated at constant temperature ϑm (mean of in- and outlet temperatures). The calculation of the annual collector performance is performed with the official Solar Keymark spreadsheet tool Scenocalc Ver (March 2016). A detailed description of the calculations is available at Additional Information Collector heat transfer medium Water-Glycole Hybrid Thermal and Photo Voltaic collector The collector is deemed to be suitable for roof integration The collector was tested successfully according to EN ISO 9806:2013 under the following conditions: Climate class (A, B or C) A -- Maximum tested positive load 2400 Pa Maximum tested negative load 3000 Pa Hail resistance using ice balls (diameter) 35 mm Energy Labelling Information Reference Area, A sol (m 2 ) Data required for CDR (EU) 811/ Reference Area A sol CRK Collector efficiency (η col ) 53 % Remark: Collector efficiency (η col ) is defined in CDR (EU) 811/2013 as collector efficiency of the solar collector at a temperature difference between the solar collector and the surrounding air of 40 K and a global solar irradiance of 1000 W/m², expressed in % and rounded to the nearest integer. Deviating from the regulation η col is based on reference area (A sol ) which is aperture area for values according to EN or gross area for ISO 9806:2013. Data required for CDR (EU) 812/ Reference Area A sol Zero-loss efficiency (η 0 ) First-order coefficient (a 1 ) 0.66 W/(m²K) Second-order coefficient (a 2 ) W/(m²K²) Incidence angle modifier IAM (50 ) Remark: The data given in this section are related to collector reference area (A sol ) which is aperture area for values according to EN or gross area for ISO Consistent data sets for either aperture or gross area can be used in calculations like in the regulation 811 and 812 and simulation programs.
Annex to Solar Keymark Certificate - Summary of EN ISO 9806:2013 Test Results
Annex to Solar Keymark Certificate - Summary of EN ISO 9806:2013 Test Results Licence Number 011-7S2434 R Date issued 2017-08-02 Issued by DIN CERTCO Licence holder Ritter Energie- und Umwelttechnik GmbH
More informationAuftrags-Nr.: Order No.: EN ISO 9806:2013 Solar energy - Solar thermal collectors - Test methods
Produkte Prüfbericht-Nr.: 21239900.001 Auftrags-Nr.: Order No.: 21239900 Kunden-Referenz-Nr.: Client Reference No.: 3141884 Auftragsdatum: Order date: 23 January 2017 Auftraggeber: Client: Viessmann Faulquemont
More informationAuftrags-Nr.: Order No.: EN ISO 9806:2013 Solar energy - Solar thermal collectors - Test methods
Produkte Prüfbericht-Nr.: 21239900.002 Auftrags-Nr.: Order No.: 21239900 Kunden-Referenz-Nr.: Client Reference No.: 3141884 Auftragsdatum: Order date: 23 January 2017 Auftraggeber: Client: Viessmann Faulquemont
More informationThe surveillance test is a physical inspection of the product and a comparison with the specifications of the original type tested sample.
SOLAR KEYMARK SPECIFIC SCHEME RULES ANNEX A2. SOLAR KEYMARK SURVEILLANCE TEST Normative annex. Version of 2012-09-09. 1 Introduction This document gives a brief description of the procedure of the so called
More informationProficiency Test. QAiST testing of solar collectors and solar systems Final Report. May, 29 th 2012
Proficiency Test QAiST testing of solar collectors and solar systems 2010-2011 Final Report May, 29 th 2012 Institut für Eignungsprüfung GmbH Daimlerstraße 8, D-45770 Marl Organisation and performance:
More informationTESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING
IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING /ALLOWED SUBCONTACTING = equired by Lab S = May be subcontracted 10.1 Visual inspection
More informationASSEMBLY INSTRUCTIONS. Construction type approved Reg. no S819 F ENERGY AND SANITARY SYSTEMS
Heliostar 252 S4 and 218 S4 FREE-STANDING INSTALLATION vertical ASSEMBLY INSTRUCTIONS Construction type approved Reg. no. 011-7S819 F ENERGY AND SANITARY SYSTEMS Safety instructions Safety instructions
More informationMeasurements of the Electrical Incidence Angle Modifiers of an Asymmetrical Photovoltaic/Thermal Compound Parabolic Concentrating-Collector
Engineering, 2013, 5, 37-43 doi:10.4236/eng.2013.51b007 Published Online January 2013 (http://www.scirp.org/journal/eng) Measurements of the Electrical Incidence Angle Modifiers of an Asymmetrical Photovoltaic/Thermal
More informationHow to Evaluate PV Project Energy Yield
How to Evaluate PV Project Energy Yield There are three main characteristics of a PV module that could affect the real energy generation of a PV plant: Temperature coefficient; Low light performance; IAM
More informationTEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval
Test Report issued under the responsibility of: TEST REPORT IEC 61215: 2005 2nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval Report Reference
More informationaurotherm VFK 990 solar collectors Affordable Solar Hot Water
aurotherm VFK 990 solar collectors Affordable Solar Hot Water 96 TRANSMISSION Works well in limited sunshine COPPER ABSORBER Provides excellent thermal conductivity WEIGHS ONLY 94 POUNDS Ensures easy on-roof
More informationOkram Oy Virtasen Maalitehdas Parainen
1 / 5 Uranus Comparative Analysis Customer: Okram Oy Virtasen Maalitehdas Parainen Target: Sample 29: TM-7742, Väritiimi Petrooliöljymaali uusi C-pohja Sample 31: TM-7411, Väritiimi Petrooliöljymaali uusi
More informationProduct Data Sheet RG160-28/18N/2TDPU-331
RG160-28/18N/2TDPU-331 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationProduct Data Sheet 8214 J/2H4P. The engineer's choice
Product Data Sheet 8214 J/2H4P The engineer's choice 8214 J/2H4P INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface
More informationCONSTRUCTION PRODUCT TECHNICAL CARD
CONSTRUCTION PRODUCT TECHNICAL CARD Product feature: Manufacturer: Flowmeter included ASPOL-FV Łódź, ul. Helska 39/45 www.aspol.com.pl Energeo Product: NOMO R Distributor cabinets with multi-sectional
More informationCONSTRUCTION PRODUCT TECHNICAL CARD
CONSTRUCTION PRODUCT TECHNICAL CARD Product feature: Manufacturer: Flowmeter included ASPOL-FV Łódź, ul. Helska 39/45 www.aspol.com.pl Energeo product: SPIDER R Distributor well with multi-sectional manifolds
More informationAn Analytical Approach Treating Three- Dimensional Geometrical Effects of Parabolic Trough Collectors
An Analytical Approach Treating Three- Dimensional Geometrical Effects of Parabolic Trough Collectors Marco Binotti Guangdong Zhu*, Ph.D., Guangdong.Zhu@nrel.gov Allison Gray National Renewable Energy
More informationBETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES
BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES TM FULL RANGE OF CERTIFIED MODULES Mono Crystalline Watt to 50 Watt Poly (Multi) Crystalline Watt to 80 Watt Glass Cells High Efficiency A-Grade
More informationHM Subsea Series. Technical Datasheet. Turbine Flow Meters. for Subsea Immersion Applications
www.kem-kueppers.com Technical Datasheet HM Subsea Series Turbine Flow Meters for Subsea Immersion Applications Certified according to DIN EN ISO 9001 2 HM Subsea Series Turbine Flow Meters Description
More informationThe European Commission s science and knowledge service
The European Commission s science and knowledge service Joint Research Centre TEMPERATURE COEFFICIENTS OF N-TYPE BIFACIAL SILICON PV MODULES UNDER NATURAL AND SIMULATED SUNLIGHT Juan Lopez-Garcia, Diego
More informationSolar Collector. (Evacuated Tube) Installation Guide, Operation & Maintenance Manual. Working towards a cleaner future
This manual must be kept with the appliance October 2010 Solar Collector (Evacuated Tube) Installation Guide, Operation & Maintenance Manual Working towards a cleaner future The content of this manual
More informationProduct Data Sheet RER190-39/14/2TDMO
RER190-39/14/2TDMO INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating Data...
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationProduct Data Sheet RER220-43/18/2TDMO
RER220-43/18/2TDMO INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating Data...
More informationProduct Data Sheet 3254 J/2H3P
3254 J/2H3P INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 7 3.3
More informationProduct Data Sheet 8452/2HHP. The engineer's choice
Product Data Sheet 8452/2HHP The engineer's choice 8452/2HHP INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Electrical Interface - Input... 5 3.2
More informationChecklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC)
Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC) Applicant: Instrument type: 1. General requirements NOTE: Definitions are based on
More informationLinear Fresnel Collectors. A Technology Overview. SFERA Summer School 2012 June 28, 2012, Almería, Spain. Jan Fabian Feldhoff
Linear Fresnel Collectors A Technology Overview SFERA Summer School 2012 June 28, 2012, Almería, Spain Jan Fabian Feldhoff E-mail: jan.feldhoff@dlr.de www.dlr.de/sf Slide 2 > SFERA Summer School 2012 >
More informationTechnical data GammaTRACER
Technical data GammaTRACER Radiological Properties GT-BASIC GT-WIDE GT-WIDE-XL GT-HIGH Type GM Tube 1 GM, 70003A/E GM, 70003A/E GM, 70031A/E GM, ZP1301/1304 Number of pulses at 100 nsv/h in 10 min 150
More informationHigh-quality pressure transmitter For general industrial applications Model S-20
Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-20 WIKA data sheet PE 81.61 Applications Critical industrial applications Demanding applications
More informationProduct Data Sheet RER225-63/18/2TDO- 406
Product Data Sheet RER225-63/18/2TDO- 406 The engineer's choice RER225-63/18/2TDO-406 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data
More informationTripping Relays AR PIN
Tripping Relays AR PIN The GEWISS Reality The company The GEWISS Group is an international company with more than 1.600 employees and with advanced manufacturing and logistics plants in Italy, Germany,
More informationProduct Data Sheet 8452/2 GHHP
8452/2 GHHP INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating Data... 5 3.3
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationProduct Data Sheet 3252J/2H3PU
3252J/2H3PU INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 7 3.3
More informationExpansion vessels for solar systems
Expansion vessels for solar systems 14 solar plus The Zilmet group Zilmet, an interationally operating company, has with 45 years experience grown to be the biggest European producer of expansion vessels.
More informationProduct Data Sheet 6424/2HP-210
6424/2HP-210 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating Data... 5
More informationFloat switch For industrial applications, plastic version Model RLS-2000
Level measurement Float switch For industrial applications, plastic version Model RLS-2000 WIKA data sheet LM 50.04 Applications Level measurement of liquids in machine building Control and monitoring
More informationOEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)
Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors
More informationThermal efficiency analysis of SkyFuel s advanced, large-aperture, parabolic trough collector
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 00 (2015) 000 000 www.elsevier.com/locate/procedia International Conference on Concentrating Solar Power and Chemical Energy Systems,
More informationComparison of squareness measurements
Slovenský metrologický ústav Slovak Institute of Metrology Slowakisches Institut für Metrologie EUROMET Supplementary Comparison #910 Comparison of squareness measurements Final Report Jiri Mokros, SMU,
More informationProduct Data Sheet 6314/2TDHP. The engineer's choice
Product Data Sheet 6314/2TDHP The engineer's choice 6314/2TDHP INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Electrical Interface - Input... 5 3.2
More informationPRODUCT FAMILY DATASHEET OSRAM DULUX D LED EM
OSRAM DULUX D LED EM LED replacement for CFLni, 2 tubes, with 2-pin G24d base for CCG and AC mains operation AREAS OF APPLICATION General illumination within ambient temperatures from - 20 +35 C Supermarkets
More informationProduct data sheet Palas Fidas 200 E
Product data sheet Palas Fidas 200 E Applications Regulatory environmental monitoring in measuring networks Ambient air measurement campaigns Long-term studies Emission source classification Distribution
More informationInstallation Instructions
Installation Instructions Alpha SolarSmart On Roof Kits for the Installation of Alpha Solar Collectors onto Tile and Slate Type Roofs For Technical help or for Service call... ALPHA HELPLINE Tel: 0 77
More informationWaist-high Railing System from Tempered Glass BH-06 ASSEMBLY AND OPERATION MANUAL
Waist-high Railing System from Tempered Glass BH-06 ASSEMBLY AND OPERATION MANUAL Waist-high Railing System from Tempered Glass BH-06 Assembly & Operation Manual Assembly & Operation Manual Dear Customers!
More informationCONSTRUCTION PRODUCT TECHNICAL CARD
CONSTRUCTION PRODUCT TECHNICAL CARD Product feature: Manufacturer: Flowmeters included ASPOL-FV Łódź, Helska st.39/45 www.aspol.com.pl Energeo product: New BRADO R Distributor well with multi-sectional
More informationOEM radar transmitter, for aggressive media level measurement
OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type
More information50-SDMS-01 SPECIFICATIONS FOR
SPECIFICATIONS FOR CURRENT TRANSFORMERS UP TO 36 KV This specification is property of SEC and subject to change or modification without any notice C O N T E N T S CLAUSE TITLE PAGE NO. ------------ --------
More informationTest Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China
Applicant... : Manufacturer... : Order No.... : Zhejiang ERA Solar Technology Co., Ltd. Sihai Road, Huangyan Economic Development Zone, Taizhou, Zhejiang 318020, P.R. China Zhejiang ERA Solar Technology
More informationRTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC
Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad
More informationTUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report
TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002 Bangalore, May 2017 Certificate No. T -1543 2 / 17 Contents CONTENTS... 2
More informationAutomatic hardness testing devices
Automatic hardness testing devices The measure of hardness, applied to rubber and plastic, is a measure of stiffness obtained from an indentation test. An indentor is pressed into the sample under a given
More information/11 PV/
IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING /ALLOWED SUBCONTACTING = equired by Lab S = May be subcontracted SPTL = Specialized Facility
More informationRG142-TNMNM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR. Regulatory Compliance/Certifications
RG142-TNMNM-3M Product Classification Product Series Product Type RG142 CNT Jumper with interface types and, 3 m RG142 Braided cable assembly General Specifications Body Style, Connector A Body Style,
More informationExplosion proof rotary actuator - On/Off or programmable regulating actuator
Explosion proof rotary actuator - On/Off or programmable regulating actuator Direct mounting for quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Type 3004 can
More informationPressure Transmitter SIL
Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute
More informationSL 200 instrument can process the energy intensity emitted by the solar radiation in a precise place of the earth.
Solarimeter SL 200 Table of contents 1 Introduction...4 2 General information...4 2.1 Measured units...4 2.2 Use...4 3 Operating principle...5 3.1 Keyboard presentation...5 3.2 Instrument offers 3 groups
More information3.2 Measurement of high voltages
DEPT OF HIGH VOLTAGE AND INSULATION ENG, HONGQING UNIVERSITY Part I- hapter 3: Insulation test techniques 3. Measurement of high voltages Instructor: Dr. Jian Li Lecture 7- DEPT OF HIGH VOLTAGE AND INSULATION
More informationPage 1 of 37. ULI-NABL(ELT)-MNRE-0053/2011 Date of issue... : Total number of pages... 37
Page 1 of 37 Test Report issued under the responsibility of: TEST REPORT IEC 61215 PV Module Safety Qualification Requirements for testing Report Reference No.... : ULI-NABL(ELT)-MNRE-0053/2011 Date of
More informationProduct Data Sheet 8214 J/2H4P
The engineer's choice 8214 J/2H4P INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical
More informationClearly Solar Solar Thermal Flat Plate Collector Installation Instructions Horizontal In-roof mounting SRH 2.3
Clearly Solar Solar Thermal Flat Plate Collector Installation Instructions Horizontal In-roof mounting 22-75 SRH 2.3 www.glow-worm.co.uk 1 Guarantee Registration These Clearly Solar Flat Plate collectors
More informationImpact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates
Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates 4th PV Performance Modelling and Monitoring Workshop 22nd and 23rd October, 2015 M. Schweiger TÜV Rheinland Energie
More informationProduct Data Sheet 622/2HHP-021
The engineer's choice 622/2HHP-021 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More informationapogeeinstruments.com Introducing the PV-100 PV Monitoring Package
apogeeinstruments.com Introducing the PV-100 PV Monitoring Package PV Monitoring Package Introducing the new PV monitoring package (PV-100) designed to work with an SMA cluster controller and offered at
More informationHigh-quality pressure transmitter For general industrial applications Model S-10
Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-10 WIKA data sheet PE 81.01 for further approvals see page 4 Applications Machine building
More informationRAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h
APPLICATION Ray is a fully electronic multi-jets compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Ray is equipped with 2 temperature sensors.
More informationHygro-ThermoTransmitter-compact xxx
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 020891/08/07 Hygro-ThermoTransmitter-compact 1.1005.54.xxx 1.1005.54.000/150/161/461/173 1.1005.54.241/441
More information&SPECIFIC FASTENING APPARATUS
HIDDEN SCREW ROOF PANEL PANELSAN &SPECIFIC FASTENING APPARATUS ROOF AND WALL MATERIAL AWARDS ROOF COVERING MATERIAL OF THE YEAR 2014 HIDDEN SCREW ROOF PANEL POLYURETHANE (PUR) POLYISOCYANURATE (PIR) INSULATED
More informationEC centrifugal fan. forward curved, dual inlet with housing (flange)
D3G46-AH- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court
More informationEN Information technology equipment Safety Part 1: General requirements
EN 61010-1 Information technology equipment Safety Part 1: General requirements Report Number....: 14PP083-01_1 Date of issue...: 2013-09-05 Total number of pages... 25 Tested by...: Thomas Rogg (printed
More information.com More than a machine. Power your life. Precise Centre Metal Lathes. Advanced Technology, Complete
Precise Centre Metal Lathes. Advanced Technology, Complete Equipment, Easy-to-Operate. This kind of MM-D420X1000 universal metal lathe machine is a fantastic model for small to medium-size turning works
More informationTUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report
TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19630304.001 Bangalore, JULY 2015 Certificate No. T -1543 2 / 8 Contents CONTENTS... 2
More informationResearch Article Numerical Study of Natural Convection Heat Loss from Cylindrical Solar Cavity Receivers
ISRN Renewable Energy, Article ID 14686, 7 pages http://dx.doi.org/1.1155/214/14686 Research Article Numerical Study of Natural Convection Heat Loss from Cylindrical Solar Cavity Receivers M. Prakash 7TrinityEnclave,OldMadrasRoad,Bangalore5693,India
More informationSKS B2 120 GD 69/11 - MA PB
SKS B2 12 GD 69/11 - MA PB Absolute maximum ratings 1) Symbol Conditions Values Unit I OUT MAX Maximum permanent output current 1 2 A RMS I IN MAX Maximum permanent input current 1 8 A DC V OUT MAX Maximum
More informationFlush pressure transmitter For viscous and solids-containing media Model S-11
Electronic pressure measurement Flush pressure transmitter For viscous and solids-containing media Model S-11 WIKA data sheet PE 81.02 Applications Machine building Hydraulic aggregates General industrial
More informationAnnex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH German Accreditation Body Annex the Accreditation Certificate D-K-15183-01-00 according DIN EN ISOIEC 17025:2005 Period of validity: 19.12.2017 18.12.2022 Holder of
More informationProduct Data Sheet DV4112/2NP-201
The engineer's choice DV4112/2NP-201 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical
More information.com More than a machine. Power your life. Precise Centre Metal Lathes. Advanced Technology, Complete
Precise Centre Metal Lathes. Advanced Technology, Complete Equipment, Easy-to-Operate. This kind of MM-D420X1500 universal metal lathe machine is a fantastic model for small to medium-size turning works
More informationPARATHOM PAR ADV 5.3 W/827 GU10
PARATHOM PAR16 50 36 ADV 5.3 W/827 GU10 PARATHOM PAR16 advanced Dimmable LED reflector lamps PAR16 with retrofit pin base Areas of application _ Spotlighting for accents _ Display cabinets and shop windows
More informationPT481/PT481F/ PT483F1
// Features. Epoxy resin package. Narrow acceptance ( θ : Typ. ± 3 ) 3. High sensitivity ( IC : MIN..mA at E e =.mw/cm ) : / ( IC : MIN..9mA at E e =.mw/cm ) : 4. Visible light cut-off type : /. Long lead
More informationHIGH PERFORMANCE SOLAR DISH CONCENTRATOR FOR STEAM GENERATION
HIGH PERFORMANCE SOLAR DISH CONCENTRATOR FOR STEAM GENERATION 04/10/2013 1.0 INTRODUCTION With the experience gained in the development of solar Heliodish Concentrators (9.0 meter Dia. X 6 nos.) during
More informationThe New Standard in Lightfastness Testing
The New Standard in Lightfastness Testing Xenon Lightfastness Tester Model B02 s The New Standard in Lightfastness Testing Designed specifically to meet ISO 105 B02, the new rotating rack Q-Sun Model
More informationInstallation instructions Vacuum tube collector CRK-12
Installation instructions Vacuum tube collector CRK-12 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de 30 62 290 04/08 GB Index 1. General
More informationPressure transmitter for general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology
More informationSafe Measurements in High-Voltage Environments CSM GmbH Computer-Systeme-Messtechnik
Safe Measurements in High-Voltage Environments < Computer-Systeme-Messtechnik Innovative Measurement and Data Technology Why Measurements are Important! Development and optimization of drive concepts for
More informationA new parabolic trough solar collector
A new parabolic trough solar collector P. Kohlenbach 1, S. McEvoy 1, W. Stein 1, A. Burton 1, K. Wong 1, K. Lovegrove 2, G. Burgess 2, W. Joe 2 and J. Coventry 3 1 CSIRO Energy Technology, PO Box 330,
More informationZHM CT Series. Technical Datasheet. Gear Flow Meters in Cartridge Design for paint applications, optimized with regard to flushing and to weight
www.kem-kueppers.com Technical Datasheet ZM CT Series Gear Flow Meters in Cartridge Design for paint applications, optimized with regard to flushing and to weight Certified zertifiziert according gemäß
More information4728 Gravois Ave. St. Louis, MO SIMAX
http://www.stemmerich.com 4728 Gravois Ave. St. Louis, MO 63116 314-832-7726 SALES 800-325-9528 FAX 314-832-7799 SIMAX DESCRIPTION: In 1837 The Kavalier Glassworks was established, and it has been making
More informationMicro IRHD Laser revolution
Micro IRHD Laser revolution Micro-IRHD Hardness tester with laser centring device and rotating sample holder for the automatic serial measure of O-rings and small rubber parts The instruments is supplied
More informationPressure transmitter for general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology
More informationISS-AX Technical Specifications. Regulator Stage. Sensor Unit. Vph4 Vph3 Vph2 Vph1. Fig 1. Block Diagram
Page: 1 of 8 Solar MEMS Technologies S.L. Sun Sensor ISS-AX Analog sensor Features Two orthogonal axes sun sensor Wide or narrow field of view High accuracy 4 analog outputs Low power consumption Wide
More informationThe New Standard in Lightfastness Testing. Q-Sun B02 Xenon Lightfastness Tester. The Lightfastness Specialists
The New Standard in Lightfastness Testing Q-Sun B02 Xenon Lightfastness Tester The Lightfastness Specialists The New Standard in Lightfastness Testing Designed specifically to meet ISO 105 B02, the new
More informationPressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Ship building Measurement and control technology
More informationGlass Systems. Technical Information on Pilkington Profilit Profiled Glass with System. - English Edition - Pilkington Profilit
Glass Systems Technical Information on Profiled Glass with System - English Edition - The - Delivery Programme Glass thickness 6 mm, flange height mm 6 7 0 K 3 8 K//7 3 6 7 6 6 6 6 6 6 50 39 486 K5 6 K3
More informationProprietary Calibration Certificate
Calibration Mark: 1003196SBR0813 1/6 Proprietary Calibration Certificate Object: thin film solar cell Manufacturer: Solibro Serial number: 130618-3A Internal serial number: SBR003 Calibration mark: 1003196SBR0813
More information