REV DCA DATE DRAWN CHECKED APPROVED PUBLISHED A W /19/13 John Rodriguez Jay Jensen Robert Davis Linda Andujo B W /01/16

Size: px
Start display at page:

Download "REV DCA DATE DRAWN CHECKED APPROVED PUBLISHED A W /19/13 John Rodriguez Jay Jensen Robert Davis Linda Andujo B W /01/16"

Transcription

1 REVISION HISTORY Refer to the DCA and associated markups for a complete description of the changes incorporated in a revision. REV DCA DATE DRAWN CHECKED APPROVED PUBLISHED A W /19/13 John Rodriguez Jay Jensen Robert Davis Linda Andujo B W /01/16 THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. NEITHER RECEIPT NOR POSSESSION OF THIS DOCUMENT CONFERS ANY RIGHT TO REPRODUCE, USE OR DISCLOSE, IN WHOLE OR IN PART, ANY INFORMATION CONTAINED IN THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION FROM WULFSBERG ELECTRONICS. Chelton Avionics, Inc. dba Wulfsberg Electronics Division Prescott, AZ CAGE CODE 1WZE2 A PRINTED COPY OF THIS DOCUMENT MAY NOT BE THE LATEST REVISION. IT IS THE USER S RESPONSIBILITY TO ENSURE THAT HE OR SHE IS USING THE LATEST DOCUMENT REVISION. THE LATEST REVISION MAY BE VIEWED OR PRINTED FROM THE ELECTRONIC DOCUMENT DISTRIBUTION SYSTEM. DOCUMENT TITLE SERVICE BULLETIN, CSB RT NARROW BAND MANDATE INSTALLED (MOD 33) SIZE A LRU RT-5000 DOCUMENT NUMBER REV B Typed signatures indicate approval. Handwritten signature approval of this document is on file at Wulfsberg Electronics, Prescott, Arizona. SCALE: NONE DO NOT SCALE DRAWING Rev. B Page 1 of 13

2 SERVICE BULLETIN EQUIPMENT: RT-5000 DATE: 4/1/2016 BULLETIN NUMBER: CSB RT REVISION: B Section 1. Planning Information 1.0 Implementation Approval Factory Repair Station Only 1.1 Compliance As Required 1.2 Description Configure DSP and enable Narrowband Mandate in the main transceiver using DSP Config Software Tool, rev H or higher and align the motherboard. Identify exceptions to the final test for units with Mod 33 applied. SWID 24 or higher is a pre-requisite for digital units, SWID 25 or higher is a pre-requisite for analog units. Also, configure Narrowband Mandate as required for XTS-5000 installed in RT Applicability Part Number XXX, 6XXX (Digital Capable) identified with SWID 24 or higher. Part Number X01 (Analog) identified with SWID 25 or higher. Note: X represents a variable digit in the part number. 1.4 Reason The FCC has released two orders, FCC and DA , which mandate migration to narrowband for Part 90 operators in certain frequency bands. This order has a deadline for compliance of January 1, As a result of these orders, United States license holders for frequencies in these bands must use 12.5 khz spectral efficient technology. Additionally, dual mode equipment 25/12.5 KHz will no longer be available for new sales in the United States. Only Part 90 mobile radio operations in the MHz VHF band and MHz UHF band fall under the mandate 1.5 Approval N/A 1.6 Costing/Parts and Labor N/A Rev. B Page 2 of 13

3 1.7 Special Equipment Required Quantity Description Part Number 1 P.C. 500 MHz Pentium -Compatible, 256MB of RAM, Microsoft Win2000/XP Professional N/A 1 RS422 Cable, RT Software Load Module, RT5DSPCFG, RT Software Configuration Obtain information for this section from the Software Configuration Index. Software Component (SWID N/A) Location Description Device Type Ver Rev Load Module Part Number N/A N/A N/A N/A N/A N/A N/A 1.8 Weights and Balance N/A 1.9 Electrical Load Data N/A 1.10 Other Publications Affected N/A 1.11 Reference Documents RT-5000 Maintenance Manual (Analog) RT-5000 Maintenance Manual (Digital) Service Bulletin: : SERVICE BULLETIN, CSB RT RT-5000 ANALOG, SWID 25 Service Bulletin: : SERVICE BULLETIN, CSB RT , RT-5000 DIGITAL INSTALL SWID 24 Section 2. Procedure Instructions 2.1 Modification Procedure CAUTION Any disassembly/assembly of this unit must be done at a static safe workstation. Removed modules should be placed in antistatic bags when not installed in the unit Rev. B Page 3 of 13

4 Open the RT-5000 and gain access to the Mother Board, in accordance with the appropriate Maintenance Manual Disassembly Procedure. Perform the following modification: * Note: Unless otherwise noted, the sequence of rework can be adjusted to facilitate the process. 1. Follow the procedure in Appendix A of this document to change the configuration of the DSP and the Main Transceiver. The configuration information that must be loaded is: RT-5000 Part Number MSM Options (if applicable)mm ENABLE FCC Narrowband Mandate 2. Follow the procedure in Appendix B of this document to Narrowband Mandate Flashcode XTS-5000 Tanapa Module. Digital Capable units only. For Analog only RT-5000 LRUs skip to step Follow the procedure in Appendix C of this document to perform Pre-test DSP Loading and Motherboard Alignment. 4. Final System Tests: Follow the procedures IAW the appropriate maintenance manual and verify the test results. All test shall pass with the following exceptions: Transmit test section with the heading: CHANNEL=3 RX FREQUENCY=155MHz TX FREQUENCY=160 MHz Test Name: TXFM SBAND MIC Vrms a. This test result will show FAIL. If this test does not fail, MOD 33 (FCC Narrowband Mandate) has not been implemented correctly. If this test does not fail, repeat Appendix A & C and configure the DSP for Narrowband Mandate Enabled. b. The measured deviation shall be within the range of 1.20 khz to 1.80 khz. If the test result shows FAIL, and the measured deviation is within this range, this test is a PASS. c. Mark each deviation failed test with CSB-51 as an indication that the failure is a PASS IAW with this procedure. 5. Identify the unit with the procedure as described in the Identification Procedure and reassemble the unit in reverse order of disassembly or, if available, in accordance with the Maintenance Manual Assembly Procedure. 2.2 Identification Procedure Mark Hardware Mod 33 on the external LRU Mod Data Label. 2.3 Acceptance Test procedures Perform a complete final acceptance / Return to Service test of the LRU in accordance with the appropriate Maintenance Manual Rev. B Page 4 of 13

5 Section 3. Material Information/Parts Required The parts required to modify this unit in accordance with this procedure are available from Cobham Aerospace at (928) ITEM QTY U/M PART NUMBER DESCRIPTION REF N/A N/A N/A N/A N/A N/A Section 4. Warranty Information This modification is considered to be a product enhancement and is not covered under warranty. Section 5. Illustrations Images provided within the procedure Rev. B Page 5 of 13

6 1. APPENDIX A RT-5000 DSP AND MAIN TRANSCEIVER CONFIGURATION 2. PURPOSE This Appendix describes how to load the RT-5000 s NVM (non-volatile memory) with configuration data using the RT5DSPCFG utility. The appropriate RT-5000 part number must be known prior to invoking this work instruction. 3. RELATED AND REFERENCE DOCUMENTS Document Number Publisher Document Title XXYY Wulfsberg Software Configuration Index, Version XX, Mod YY, RT Wulfsberg Configuration Index Document, RT-5000 Transceiver (Digital) Wulfsberg Interface Specification, Serial Control Bus, RS-422, RT REQUIRED EQUIPMENT AND PARTS Data Obtain the RT-5000 part number specified by the Test Procedure or Work Instruction invoking this work instruction. Software The following software must be installed on the computer prior to invoking this work instruction: RT5DSPCFG (Wulfsberg load module , rev H or greater) Computer (PC) Although RT5DSPCFG should run on any computer capable of running a recent version of Microsoft Windows, the following minimum hardware configuration is recommended: CPU 500 MHz Pentium -compatible CPU Memory 256 MB of RAM Display SVGA (800 X 600) or better display Operating System Microsoft Windows 2000/XP Professional I/O Ports One COM port(s) Cables The PC must be able to communicate with the RT-5000 via RS-422. An RS-422/RS-232 converter must be used so the PC s COM port (RS-232) can communicate with the RT-5000 (RS-422). Breakout Cable (Wulfsberg part number ) Allows access to the RT-5000 s RS-422 lines Rev. B Page 6 of 13

7 RS-422/RS-232 Converter (B&B Electronics Model 422PP9R or equivalent) Converts RS-422 signal levels into RS-232 signal levels 1) Or TSH-5000 Box built to Revision G or higher which includes the RS-232/RS- 422 converter and a switch to allow PC control for the purpose of running this configuration utility. Power Supply The RT-5000 requires a 28V DC, 10A power supply. Procedure 4.1 PREPARE THE RT-5000 TO RECEIVE THE CONFIGURATION DATA If not already connected, connect the PC, RT-5000, Power Supply, Cable, and RS-422/RS-232 Converter as shown in Figure 2. Select PC control on TSH-5000 Serial Box RT5000/PC control switch. Apply power to the RT-5000 Wait 10 seconds for RT-5000 to complete its initialization 4.2 START THE RT5DSPCFG UTILITY Open the RT5DSPCFG utility by double clicking the RT5DSPCFG icon on the Windows Desktop. 4.3 ENTER THE COM PORT NAME Enter the name of the COM (Serial) port to use for communicating with RT-5000 in the COM field. Refer to Figure 1 for the COM field s location. The default is COM CONFIGURE THE DSP Enter the last 4-digits of the RT-5000 part number of the unit being configured in the P/N field. Refer to Figure 1 for the P/N field s location. The default is CONFIGURE MSM OPTIONS (IF APPLICABLE) Place a check in the MSM Option box if this RT-5000 has the Etherstack MSM module installed. Place a check in the Encryption box if the installed Etherstack MSM module supports encryption. Note this option is only available if the MSM Option box is checked. Place a check in the Trunking box if the installed Etherstack MSM module supports trunking. Note this option is only available if the MSM Option box is checked. 4.6 CONFIGURE FCC NARROWBAND MANDATE OPTION If MOD 33 is installed into the radio: Place a check in the Enforce FCC Narrowband Mandate box (i.e. the RT-5000 is to comply with the FCC s narrowband mandate). If MOD 33 is NOT installed into the Radio Ensure that there is NO CHECK in the Enforce FCC Narrowband Mandate box. If there IS a check in this box, uncheck it. (i.e. DISABLE Narrowband Mandate). 4.7 START CONFIGURATION PROCESS Click the Configure button to begin downloading the specified configuration data into the RT If the Unable to open COM error dialog is displayed, RT5DSPCFG was unable to open the COM port specified in 4.3. Ensure the specified COM port is valid for the PC in use, and that no other Rev. B Page 7 of 13

8 programs are using the COM port. If the problem persists, contact the appropriate IT/IS personnel. A sample of the Unable to open COM error dialog is given below. If the Cannot find configuration file error dialog is displayed, RT5DSPCFG was unable to find a data configuration file for the RT-5000 part number specified in 4.4. Ensure the specified part number is correct and try again. If the problem persists, contact the appropriate Engineering personnel. The problem is most likely a missing configuration data file, but could result from an incorrect installation of RT5DSPCFG. A sample of the Cannot find configuration file error dialog is given below. 4.8 AWAIT COMPLETION The configuration process may take several minutes. The progress bar at the bottom of RT5DSPCFG s screen shows the percent complete. RT5DSPCFG s Log Window field displays diagnostic information, including the messages being transmitted over the RS-422 link. Refer to Figure 1 for the Log Window field s location. If the Communication timeout expired error dialog is displayed, RT5DSPCFG was unable to communicate with the RT Ensure the RT-5000 is connected to the PC via the COM port specified in 4.3. Ensure the RT-5000 is powered on and is alive. Cycle power on the RT-5000 and retry. If the problem persists, contact the appropriate Engineering personnel. A sample of the Communication timeout expired error dialog is given below. If the Communication retry limit exceeded error dialog is displayed, RT5DSPCFG detected errors during communication with the RT-5000, and was unable to correct the problem before the retry limit was exceeded. Cycle power on the RT-5000 and retry. If the problem persists, contact the appropriate Engineering personnel. A sample of the Communication retry limit exceeded error dialog is given below Rev. B Page 8 of 13

9 If the RT-5000 successfully configured dialog is displayed, RT5DSPCFG has finished loading the RT-5000 with the required configuration data. A sample of the RT-5000 successfully configured dialog is given below. 4.9 FINISH Close the RT5DSPCFG utility Select RT5K on TSH-5000 Serial Box RT5000/PC control switch. Cycle power on the UUT Return to the procedure that invoked this work procedure Figure 1 RT5DSPCFG Screen Rev. B Page 9 of 13

10 Banana 28V Power Supply RT RS-422 RS422/RS232 Converter RS-232 PC Figure 2 Connection Diagram Rev. B Page 10 of 13

11 1. APPENDIX B NARROWBAND MANDATE FLASHCODE MODIFICATION PROCEDURE (XTS-5000 TANAPA MODULE). The required XTS-5000 Narrowband Mandate state (enable / disable) for this procedure is specified in the calling Test Procedure or Work Instruction. 1.1 IDENTIFY CODEPLUG Note that the UHF-800 does NOT have Narrowband Mandate option capability. Use nn04 ONLY for Enable OR Disable. 1. From table 1, find the required FLASHcode for the required Narrowband Mandate state Enable or Disable. This tells you to use either nn04 OR nn02 codeplug 2. From the same line of table 1, find the XTS-5000 Part Number. This defines nn, where nn = XTS-5000 Part Number dash number from nn in table The document number for the default codeplug will be either nn02 (archnn02) or nn04 (archnn04) per table 1. Frequency Range MHz VHF MHz UHF-LO MHz UHF-HI Frequency Range MHz UHF-800 Narrowband Mandate Flashcode Enable nn04 Disable -nn02 XTS-5000 Part Number Description MHz, XTS MHz, XTS MHz, XTS MHz, XTS MHz, XTS MHz, XTS MHz, XTS MHz, XTS MHz, XTS-5000 Default Flashcode NO Narrowband Mandate Use nn04 ONLY XTS-5000 Part Number Description MHz, XTS MHz, XTS MHz, XTS-5000 Table 1: Flashcode Reference 1.2 LOAD CODEPLUG LOAD CODEPLUG VHF, UHF-LO, UHF-HI 1. Start the MOTOROLA DEPOT TOOL Software, wait for the software to load. 2. Select File -> Open and open the Codeplug identified in Appendix B, Section Select Tools -> Cloning -> Clone Radio -> Read Serial Number and wait for the Depot Tool to finish. 4. Select Tools -> Depot -> Write Codeplug and wait for the Depot Tool to finish. 5. Close the current Codeplug. 6. Select Depot -> Read Codeplug 7. Select Tree View -> Radio Information -> Feature Set 8. Verify that FCC Mandate (Q507) is present ONLY for Narrowband Mandate Enabled XTS Modification complete Rev. B Page 11 of 13

12 1.2.2 LOAD CODEPLUG UHF Start the MOTOROLA DEPOT TOOL Software, wait for the software to load 2. Select File -> Open and open the Codeplug identified in Appendix B, Section Verify the Trunking -> Trunking Configuration -> Rebanding Enabled Box is selected 4. Select DEPOT -> UPDATE CODEPLUG 5. Change the serial number to reflect the radio you are loading to 6. Select Update Codeplug 7. Save updated Codeplug as new file name 8. Exit Depot Tool 9. Start the MOTOROLA DEPOT TOOL Software, wait for the software to load 10. Select File -> Open and open the Codeplug just saved in Step Verify the Trunking -> Trunking Configuration -> Rebanding Enabled Box is selected 12. Select DEPOT and WRITE CODEPLUG 13. Select Yes when it asks to write to the radio 14. Modification complete Rev. B Page 12 of 13

13 1. APPENDIX C 1.1 CATEGORY A: PRE-TEST DSP LOADING AND MOTHERBOARD ALIGNMENT 1) For RT-5000 radios with Hardware Mod 14 ( Motherboard), verify DIP SWITCH settings for SW 1 and SW 2 as follows. For radio p/n XX through XX (Analog Flavors): SW 1: 1=OFF, 2=OFF, 3=OFF, 4=ON, 5=ON, 6=ON, 7=OFF, 8=OFF SW 2: 1=OFF, 2=OFF, 3=OFF, 4=OFF For radio p/n XX through xx (Analog RT-5000P Flavors): SW 1: 1=ON, 2=ON, 3=ON, 4=OFF, 5=OFF, 6=OFF, 7=OFF, 8=OFF SW 2: 1=OFF, 2=OFF, 3=OFF, 4= OFF For radio p/n XX through XX (Digital MTM Flavors): SW 1: 1=ON, 2=ON, 3=ON, 4=OFF, 5=OFF, 6=OFF, 7=ON, 8=ON SW 2: 1=ON, 2=ON, 3= OFF, 4=OFF For radio p/n XX through XX (Digital RT-5000P Flavors) SW 1: 1=ON, 2=ON, 3=ON, 4=OFF, 5=OFF, 6=OFF, 7=ON, 8=OFF SW 2: 1=OFF, 2=OFF, 3= OFF, 4=OFF 2) Connect the RT-5000 to the ATE System as shown in Figure 1. 3) Press <CTRL> S on the Bigfoot ATE computer keyboard to enable the System Control softkeys. 4) Press F3 to select the System Configuration softkeys. 5) Press F8 then F5 to select the Program menu page. 6) Use the UP/DOWN arrow keys to select the MBSETUP program then press <ENTER>. 7) After the program has loaded press F1 to return to the System Control softkeys. 8) Press F1 to begin the DSP Loading and Motherboard Alignment procedure. Follow any instructions on the computer screen. 9) TX DEVIATION Adjustment Deviate from the on-screen instructions as follows: Standard Band Adjustment: Adjust R122 for 1.5 khz Deviation instead of 3.0 khz. Wide Band Adjustment: Adjust R107 for 1.6 khz Deviation instead of 3.3 khz. Extra Wide Band Adjustment: Adjust R102 for 1.6 khz Deviation instead of 3.3 khz. 10) Verify Alignment Results After completion of the pre-environmental tests, note any failures on the printout sheet. All tests shall PASS except for: The adjustment of Potentiometer R122: TX FM MIC INPUT STD DEV: The adjustment of Potentiometer R107: TX FM WIDE BAND INPUT DEV: and The adjustment of Potentiometer R102: TX FM XWIDE BAND INPUT DEV: These three test results will show FAIL. If these tests do not fail, MOD 33 (FCC Narrowband Mandate) has not been implemented correctly. If these tests do not fail, repeat Appendix A Section 4 and configure the DSP for Narrowband Mandate Enabled. The measured deviations for these three tests shall be within the range: o For TX FM MIC INPUT STD DEV: 1.20 khz to 1.80 khz. o For TX FM WIDE BAND INPUT DEV: 1.20 khz to 1.80 khz. o For TX FM XWIDE BAND INPUT DEV: 1.20 khz to 1.80 khz. If all three test results show FAIL, and the measured deviations are within this ranges shown, these tests are a PASS. Do not proceed with further system testing unless all tests PASS END Rev. B Page 13 of 13

REV DCA DATE DRAWN CHECKED APPROVED PUBLISHED A W /13/2014 Ken Marshall Heath Flor Jay Jensen Linda Andujo

REV DCA DATE DRAWN CHECKED APPROVED PUBLISHED A W /13/2014 Ken Marshall Heath Flor Jay Jensen Linda Andujo REVISION HISTORY Refer to the DCA and associated markups for a complete description of the changes incorporated in a revision. REV DCA DATE DRAWN CHECKED APPROVED PUBLISHED A W13295 03/13/2014 Ken Marshall

More information

TECHNICAL INFORMATION BULLETIN

TECHNICAL INFORMATION BULLETIN TECHNICAL INFORMATION BULLETIN T/B No.: TIBFM 15-02 Rev A Revision date: JUNE24/08 Issue Date: JUNE18/08 TiL Model: TDFM-600/6000/7000 transceivers with Type I or Type II modules. TiL P/N: 011210-1,-2,-3,-4,-5

More information

PC Tune PC Tune Test Procedures for 5100 Series Portable Radios

PC Tune PC Tune Test Procedures for 5100 Series Portable Radios PC Tune PC Tune Test Procedures for 5100 Series Portable Radios Part Number 002-9998-6513014 August 2008 Copyright 2006, 2007, 2008 by EFJohnson Technologies The EFJohnson Technologies logo, PC Configure,

More information

SERVICE BULLETIN EQUIPMENT: RT-138 DATE: JULY 15, This Service Bulletin applies to all RT-138 Flexcomm I Transceivers, P/N XXX.

SERVICE BULLETIN EQUIPMENT: RT-138 DATE: JULY 15, This Service Bulletin applies to all RT-138 Flexcomm I Transceivers, P/N XXX. Wulfsberg Electronics Division A Chelton Group Company 6400 Wilkinson Prescott, AZ 86301 U.S.A. Telephone: (520) 708-1550 Fax: (520) 541-7627 Cognizant Engineer: R. DeLong DOES NOT CHANGE ORIGINAL APPROVAL

More information

Guardian and DL3282 Modem Interface Technical Service Application Note

Guardian and DL3282 Modem Interface Technical Service Application Note Guardian and DL3282 Modem Interface Technical Service Application Note OVERVIEW The following document is designed to provide information for the implementation of the Guardian Wireless Modem/Analog Radio

More information

APX Mobile and Portable Automated Test and Alignment

APX Mobile and Portable Automated Test and Alignment APX Mobile and Portable Automated Test and Alignment Software Updates First things first! Be sure to check that you are running the latest software versions for the 8800SX and its applications. Visit the

More information

IC-400pro - RADIOAFICION.COM

IC-400pro - RADIOAFICION.COM PROCEDURES IC-400pro - 5- PREPARATION When you adjust the contents on pages 5-5 and 5-6, SOFT- WARE, the optional CS-400PRO ADJ SOFTWARE (Rev..0 or later), *OPC- JIG CABLE (modified OPC- CLONING CABLE;

More information

ASTi SYNAPSE Remote Control Guide Document: DOC-01-SYN-RC-1

ASTi SYNAPSE Remote Control Guide Document: DOC-01-SYN-RC-1 ASTi SYNAPSE Remote Control Guide Document: DOC-01-SYN-RC-1 Advanced Simulation Technology inc. 500A Huntmar Park Drive, Herndon, Virginia, 20170 USA Revision B (Oct., 2011) Product Name: ASTi Synapse

More information

Mastr III P25 Base Station Transmitter Tune-up Procedure

Mastr III P25 Base Station Transmitter Tune-up Procedure Mastr III P25 Base Station Transmitter Tune-up Procedure 1. Overview The Mastr III Base Station transmitter alignment is performed in several steps. First, the Transmit Synthesizer module is aligned to

More information

Ground System Training Department

Ground System Training Department Module 7: IPSTAR Uplink Access Test (IUAT) Ground System Training Department 2012-03-Standard (iuat1.14)-uti-101 THAICOM Public Company Limited Module Objectives At the end of the module the participant

More information

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6 ST-965 VX/D SMARTRUNK II & SMARTRUNK XPRESS Logic board Programming Software 2.9e User s Guide Revision R2.9 10/10/2008 INDEX INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3

More information

Issue No: MG025 Date: 05 June McMurdo SmartFind R5 GMDSS Radio IMO MSC. 1/Circ Update procedure

Issue No: MG025 Date: 05 June McMurdo SmartFind R5 GMDSS Radio IMO MSC. 1/Circ Update procedure Installation SERVICE BULLETIN Issue No: MG025 Date: 05 June 2017 McMurdo SmartFind R5 GMDSS Radio IMO MSC. 1/Circ. 1460 Update procedure Product Affected: McMurdo R5 GMDSS VHF Handheld Radio Reason: Compliance

More information

Configuration of the Pacific Crest Radios using PDLCONF software PDL Base Radio

Configuration of the Pacific Crest Radios using PDLCONF software PDL Base Radio Configuration of the Pacific Crest Radios using PDLCONF software PDL Base Radio This document will guide user s through configuration of the PDL Base Radio. Required items: PDL Base Radio, PDL Config software,

More information

YCE13. Dealer PC Programming Software Reference Manual. Attention!

YCE13. Dealer PC Programming Software Reference Manual. Attention! YCE13 Dealer PC Programming Software Reference Manual Attention! The YCE13 programing software can only be used with HX380/400 firmware version Ver. 2.00 or later. This software is used to program the

More information

Agilent N7509A Waveform Generation Toolbox Application Program

Agilent N7509A Waveform Generation Toolbox Application Program Agilent N7509A Waveform Generation Toolbox Application Program User s Guide Second edition, April 2005 Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced

More information

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master Measurement Guide Power Meter for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master Power Meter Option 29 High Accuracy Power Meter Option 19 Inline Peak

More information

PROGRAMMING MANUAL PCCONFIGURE SOFTWARE. December 2004 Part No

PROGRAMMING MANUAL PCCONFIGURE SOFTWARE. December 2004 Part No PROGRAMMING MANUAL PCCONFIGURE PROGRAMMING SOFTWARE December 2004 Part No. 002-9998-488 11 PCCONFIGURE PROGRAMMING SOFTWARE USER MANUAL This manual covers PCConfigure Versions through 1.26.0. Copyright

More information

LD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18

LD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18 LD2342 USWM V1.6 LD2342 V1.4 Page 1 of 18 GENERAL WARNINGS All Class A and Class B marine Automatic Identification System (AIS) units utilize a satellite based system such as the Global Positioning Satellite

More information

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6 ST-965 KW/D SMARTRUNK II & SMARTRUNK XPRESS Logic board Programming Software 2.9e User s Guide Revision R2.9.8 12/30/2008 INDEX INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3

More information

VHF/AM SINGLE CHANNEL TRANSMITTERS Model TiL-92-SC

VHF/AM SINGLE CHANNEL TRANSMITTERS Model TiL-92-SC VHF/AM SINGLE CHANNEL TRANSMITTERS Model TiL-92-SC 25 WATT TX, P/N 931037-1 TST-4100 15 WATT TX, P/N 931038-1 TST-4200 LOW POWER TX, P/N 931039-1 TST-4300 Installation and Operating Instructions TiL Document

More information

Revision WI.232FHSS-25-FCC-R and RK-WI.232FHSS-25-FCC-R USER S MANUAL

Revision WI.232FHSS-25-FCC-R and RK-WI.232FHSS-25-FCC-R USER S MANUAL Revision 1.0.3 WI.232FHSS-25-FCC-R and RK-WI.232FHSS-25-FCC-R USER S MANUAL RADIOTRONIX, INC. WI.232FHSS-25-FCC-R/ RK-WI.232FHSS-25-FCC-R USER S MANUAL Radiotronix 905 Messenger Lane Moore, Oklahoma 73160

More information

WIRES-X Portable Digital Node Function. Instruction Manual

WIRES-X Portable Digital Node Function. Instruction Manual Wide-Coverage Internet Repeater Enhancement System WIRES-X Portable Digital Node Function Instruction Manual Please read this Instruction Manual carefully for appropriate procedure. Preparation Procedure

More information

WEB I/O. Wireless On/Off Control USER MANUAL

WEB I/O. Wireless On/Off Control USER MANUAL Wireless On/Off Control Technical Support: Email: support@encomwireless.com Toll Free: 1 800 617 3487 Worldwide: (403) 230 1122 Fax: (403) 276 9575 Web: www.encomwireless.com Warnings and Precautions Warnings

More information

FOD Transmitter User s Guide

FOD Transmitter User s Guide FOD Transmitter User s Guide Rev 5, 05/21/2014 AVID Technologies, Inc. FOD Transmitter User s Guide Page 2 General Description The AVID FOD (Foreign Object Detection) Transmitter is a standard WPC Qi V1.1

More information

LBI-38808B. Maintenance Manual EDACS UTILITY PROGRAMMING

LBI-38808B. Maintenance Manual EDACS UTILITY PROGRAMMING LBI-38808B Maintenance Manual EDACS UTILITY PROGRAMMING NOTICE! Repairs to this equipment should be made only by an authorized service technician or facility designated by the supplier. Any repairs, alterations

More information

VX-2100/VX-2200 (UHF) Alignment

VX-2100/VX-2200 (UHF) Alignment VX-2100/VX-2200 (UHF) Introduction The VX-2100/2200 is carefully aligned at the factory for the specified performance across the frequency range specified for each version. Realignment should therefore

More information

TECHNICAL NOTES. MT-4 Radio Systems. TN247 VR-4E VHF MT-4E Receiver. Specifications. Models Available. Receiver Operating Frequency

TECHNICAL NOTES. MT-4 Radio Systems. TN247 VR-4E VHF MT-4E Receiver. Specifications. Models Available. Receiver Operating Frequency MADE IN CANADA TN247 VR-4E VHF MT-4E Receiver USB CNTL BUS A D RECEIVER FREQUENCY (MHz) SQ. DISABLE NORM OFF REF IN RF IN The VR-4E VHF receiver is an FM radio module capable of analog operation in 12.5

More information

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LincView OPC Enhanced Diagnostics Utility It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of

More information

FCC ID: AXI IC: 10239A Alignment

FCC ID: AXI IC: 10239A Alignment Introduction The VX-261 is carefully aligned at the factory for the specified performance across the frequency range specified for each version. Realignment should therefore not be necessary except in

More information

Quick Immunity Sequencer

Quick Immunity Sequencer Part No. Z1-003-152, IB006433 Nov. 2006 USERʼS MANUAL PCR-LA Series Application Software SD003-PCR-LA Quick Immunity Sequencer Ver. 1.0 Use of This Manual Please read through and understand this User s

More information

Ordering Guide. VRX1000 Vehicle Radio Extender. 8A087X01 Revision 2.7. April 20, 2018

Ordering Guide. VRX1000 Vehicle Radio Extender. 8A087X01 Revision 2.7. April 20, 2018 Ordering Guide VRX1000 Vehicle Radio Extender 8A087X01 Revision 2.7 Contents Revision History... 3 Ordering Instructions PLEASE READ CAREFULLY... 4 Important Notes... 5 1. VRX1000 Base Transceiver Frequency

More information

Getting Started with TrangoLink

Getting Started with TrangoLink Getting Started with TrangoLink Overview: TrangoLink allows you to configure and monitor your EAGLE PLUS, FALCON, or PTZ-900 transmitters and receivers. On the EAGLE PLUS and FALCON transmitters, you can

More information

CDF-992 DIRECTION FINDER, CONTROL DISPLAY, SYSTEM-7 PILOTS GUIDE

CDF-992 DIRECTION FINDER, CONTROL DISPLAY, SYSTEM-7 PILOTS GUIDE Chelton Avionics, Inc. (dba Wulfsberg Electronics), located in Prescott, Arizona, designs and manufactures the CDF-992 Direction Finder, Control Display, System-7. For more than 25 years, Chelton Avionics,

More information

AUTOTUNE USER GUIDE. R8000 Series Communications Systems Analyzer. Motorola ASTRO XTL Series Motorola ASTRO XTS Series

AUTOTUNE USER GUIDE. R8000 Series Communications Systems Analyzer. Motorola ASTRO XTL Series Motorola ASTRO XTS Series R8000 Series Communications Systems Analyzer AUTOTUNE USER GUIDE Motorola ASTRO XTL Series Motorola ASTRO XTS Series Freedom Communication Technologies 2002 Synergy Blvd, Suite 200 Kilgore, Texas 75662

More information

LBI Installation & Operation

LBI Installation & Operation Installation & Operation EDACS Power Monitor Unit ericssonz CONTENTS TABLE OF CONTENTS Page INTRODUCTION... 6 DESCRIPTION... 6 APPLICATION NOTES... 7 VAX SITE CONTROLLER COMPUTER... 7 APPLICATION SOFTWARE

More information

MINIMUM SYSTEM REQUIREMENTS

MINIMUM SYSTEM REQUIREMENTS Quick Start Guide Copyright 2000-2012 Frontline Test Equipment, Inc. All rights reserved. You may not reproduce, transmit, or store on magnetic media any part of this publication in any way without prior

More information

AUDIO MODE SELECTOR MODEL AMS-6000

AUDIO MODE SELECTOR MODEL AMS-6000 AUDIO MODE SELECTOR MODEL AMS-6000 Installation and Operating Instructions Til Document No. 03RE325 Rev. n/c Issue 4 August 2007 Technisonic Industries Limited 240 Traders Boulevard, Mississauga, Ontario

More information

WIRES-X Portable Digital Node Function. Instruction Manual

WIRES-X Portable Digital Node Function. Instruction Manual Wide-Coverage Internet Repeater Enhancement System WIRES-X Portable Digital Node Function Instruction Manual Please read this Instruction Manual carefully for appropriate procedure. Preparation Procedure

More information

MANUAL. Textron Motors Diagnostic Tool. This manual is valid for the following Textron Motors Diagnostic Tool:

MANUAL. Textron Motors Diagnostic Tool. This manual is valid for the following Textron Motors Diagnostic Tool: MANUAL Textron Motors Diagnostic Tool This manual is valid for the following Textron Motors Diagnostic Tool: 0507 TD0507_HB Rev F 6..05 en_english Read the manual before performing the task on the engine.

More information

NEXEDGE Type-D Trunking System

NEXEDGE Type-D Trunking System NEXEDGE Type-D Trunking System 2015.26.05 Copyright 2014 JVCKENWOOD Corporation. All rights reserved. 1. Type-D Trunking Overview 1. Type-D Trunking System Overview NEXEDGE Type-D Trunking System New affordable

More information

SIGNAL PROCESSOR CARD 531X309SPC G1

SIGNAL PROCESSOR CARD 531X309SPC G1 (Supersedes GEI-100024) SIGNAL PROCESSOR CARD 531X309SPC G1 These instructions do not purport to cover all details or variations in equipment, nor to provide every possible contingency to be met during

More information

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22. USER MANUAL - Intelligent Positioner Control Unit 1/22 Table of contents: 1 General... 3 1.1 Safety instructions... 3 2 Application... 4 3 Electrical specifications and terminals... 5 3.1 Control loop...

More information

Tactical Communication Products: RT-2000 Remote Mounted Transceiver

Tactical Communication Products: RT-2000 Remote Mounted Transceiver PRODUCT DESCRIPTION s Single or Dual, Analog/Digital, P-25 Transceivers VHF-Hi, UHF, 800, 700/800 MHz bands The Wulfsberg RT-2000 is a FM Tactical transceiver that incorporates one or two transceiver modules

More information

AUTOTUNE USER GUIDE. R8000 Series Communications Systems Analyzer

AUTOTUNE USER GUIDE. R8000 Series Communications Systems Analyzer R8000 Series Communications Systems Analyzer AUTOTUNE USER GUIDE Portable Radios Motorola APX 2000 Motorola APX 4000 Motorola APX 6000 Motorola APX 7000 Mobile Radios Motorola APX 2500 Motorola APX 4500

More information

RPS-9000 Programming Software for the TYT TH-9000

RPS-9000 Programming Software for the TYT TH-9000 for the TYT TH-9000 Memory Types Memories Limit Memories VFO Channels Receive Frequency Transmit Frequency Offset Frequency Offset Direction Channel Spacing Name Tone Mode CTCSS Rx CTCSS DCS Rx DCS Memory

More information

----STAR S86 GPS Receiver. User Guide. SOUTH CO., Ltd.

----STAR S86 GPS Receiver. User Guide. SOUTH CO., Ltd. ----STAR S86 GPS Receiver User Guide SOUTH CO., Ltd. www.southsurveying.com Sales@SOUTHsurveying.com 2 CONTENTS Chapter 1 Introduction... 1 STAR S86 GPS - System Summary... 1 Technical Specification...

More information

DMR Radio Authorization Operation Guide

DMR Radio Authorization Operation Guide DMR Radio Authorization Copyright Information Hytera is the trademark or registered trademark of Hytera Communications Corporation Limited in PRC and/or other countries or areas. Hytera retains the ownership

More information

Key Reference. Agilent Technologies E8257D/67D PSG Signal Generators. Manufacturing Part Number: E Printed in USA July 2007

Key Reference. Agilent Technologies E8257D/67D PSG Signal Generators. Manufacturing Part Number: E Printed in USA July 2007 Agilent Technologies E8257D/67D PSG Signal Generators This guide applies to the following signal generator models: E8267D PSG Vector Signal Generator E8257D PSG Analog Signal Generator Due to our continuing

More information

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual THE HIGH PERFORMANCE COMPANY Series 70 Hold 1 sec. Hold 1 sec. FOR MORE INFORMATION ON THIS PRODUCT AND OTHER BRAY PRODUCTS PLEASE VISIT OUR WEBSITE www.bray.com Table of Contents 1. Definition of Terms.........................................2

More information

Houston Radar LLC. Installation and User Manual For. Doppler Radar DR-1500

Houston Radar LLC. Installation and User Manual For. Doppler Radar DR-1500 Houston Radar LLC Installation and User Manual For Doppler Radar DR-1500 Houston Radar LLC 13814 Sherburn Manor Dr. Cypress.TX Http://www.Houston-Radar.com Email: sales@houston-radar.com Contact: (281)

More information

Hytera. PD41X Patrol Management System. Installation and Configuration Guide

Hytera. PD41X Patrol Management System. Installation and Configuration Guide Hytera PD41X Patrol Management System Installation and Configuration Guide Documentation Version: 01 Release Date: 03-2015 Copyright Information Hytera is the trademark or registered trademark of Hytera

More information

Transmitter. User Manual. Firmware version 1.0 and greater

Transmitter. User Manual. Firmware version 1.0 and greater ProRF SPC Transmitter User Manual Firmware version 1.0 and greater FCC NOTICE This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the

More information

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301)

More information

Blue Bamboo P25 Device Manager Guide

Blue Bamboo P25 Device Manager Guide Blue Bamboo P25 Device Manager Guide Version of Device Manager: 1.1.28 Document version: 2.3 Document date: 2011-09-20 Products: P25 / P25-M / P25i / P25i-M BLUE BAMBOO Headquarters Blue Bamboo Transaction

More information

Dragon. manual version 1.7

Dragon. manual version 1.7 Dragon manual version 1.7 Contents DRAGON TOP PANEL... 2 DRAGON STARTUP... 2 DRAGON STARTUP SCREEN... 2 DRAGON INFO SCREEN... 3 DRAGON MAIN SCREEN... 3 TURNING ON A TRANSMITTER... 4 CHANGING MAIN SCREEN

More information

MIDLAND RADIO CORPORATION

MIDLAND RADIO CORPORATION MIDLAND RADIO CORPORATION SECURITY POLICY Syn-Tech III P25 Portable Radio (VHF and UHF) Syn-Tech III P25 Dash Mount Mobile Radio (VHF and UHF) Syn-Tech III P25 Trunk Mount Mobile Radio (VHF and UHF) Syn-Tech

More information

G3P-R232. User Manual. Release. 2.06

G3P-R232. User Manual. Release. 2.06 G3P-R232 User Manual Release. 2.06 1 INDEX 1. RELEASE HISTORY... 3 1.1. Release 1.01... 3 1.2. Release 2.01... 3 1.3. Release 2.02... 3 1.4. Release 2.03... 3 1.5. Release 2.04... 3 1.6. Release 2.05...

More information

Model 1791 VHF Radio User's Manual

Model 1791 VHF Radio User's Manual Model 79 VHF Radio User's Manual ALL WEATHER INC 65 NATIONAL DRIVE SACRAMENTO, CA 95834 WWW.ALWEATHERINC.COM 79 VHF RADIO USER'S MANUAL CONTENTS INTRODUCTION... Description... Transmitter Module... Power

More information

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K O P E R A T I N G I N S T R U C T I O N S WEL-200 TM W I R E L E S S E D G E L I N K 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com

More information

LCC-100 software User manual

LCC-100 software User manual User Manual Pressure Temperature Humidity Air Velocity Airflow Sound level New LCC-100 software User manual Configuration software for Monostats - Class 50 and 100 units - ranges - relays - set points

More information

SUBJECT: Flash: RM4 UCONNECT AM/FM/BT/NAV/Voice Navigating Resets When Driving

SUBJECT: Flash: RM4 UCONNECT AM/FM/BT/NAV/Voice Navigating Resets When Driving NUMBER: 08-054-14 GROUP: Electrical DATE: June 27, 2014 This bulletin is supplied as technical information only and is not an authorization for repair. No part of this publication may be reproduced, stored

More information

MODEL FVP-44. Setup & Programming Manual

MODEL FVP-44. Setup & Programming Manual MODEL FVP-44 Rolling Code Encryption board for VX-450 / VX-4500 / VX-4600 VERTEX/STANDARD RADIOS Setup & Programming Manual Installation: Running the installation program, CimarronQuikWareSetupFVP44.EXE,

More information

IB Nov User s Manual. KFM Series Application Software. FCTester. Ver. 1.1

IB Nov User s Manual. KFM Series Application Software. FCTester. Ver. 1.1 IB011511 Nov. 2006 User s Manual KFM Series Application Software FCTester Ver. 1.1 Use of This Manual Please read through and understand this User s Manual before operating the product. After reading,

More information

Quick Start. Precis-BX305. Precise GNSS RTK Board.

Quick Start. Precis-BX305. Precise GNSS RTK Board. Quick Start Precis-BX305 Precise GNSS RTK Board www.tersus-gnss.com December, 2016 Quick Start Guide of Precis-BX305 This quick start guide provides the basic information needed to set up and use Precis-BX305

More information

SPECIFICATION FOR UHF HANDHELD AND DESKTOP RADIOS FOR SHUNT YARDS

SPECIFICATION FOR UHF HANDHELD AND DESKTOP RADIOS FOR SHUNT YARDS SPECIFICATION UHF HANDHELD AND DESKTOP RADIOS FOR SHUNT YARDS A Division of Transnet Limited Registration Number 1990/000900/06 SPECIFICATION FOR UHF HANDHELD AND DESKTOP RADIOS FOR SHUNT YARDS SPC-01284

More information

"Terminal RG-1000" Customer Programming Software. User Guide. August 2016 R4.3

Terminal RG-1000 Customer Programming Software. User Guide. August 2016 R4.3 "Terminal RG-1000" Customer Programming Software User Guide August 2016 R4.3 Table of Contents Table of Contents Introduction 2 3 1.1 Software installation 3 1.2 Connecting the RG-1000 GATEWAYs to the

More information

PROGRAMMING MANUAL PCCONFIGURE SOFTWARE. March 2004 Part No

PROGRAMMING MANUAL PCCONFIGURE SOFTWARE. March 2004 Part No PROGRAMMING MANUAL PCCONFIGURE PROGRAMMING SOFTWARE March 2004 Part No. 002-9998-488 8 PCCONFIGURE PROGRAMMING SOFTWARE USER MANUAL This manual covers PCConfigure Versions through 1.22.0 Copyright 2004

More information

5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version valontechnology.com

5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version valontechnology.com 5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version 1.6.1 valontechnology.com 5008 Dual Synthesizer Module Configuration Manager Program Version 1.6.1 Page 2 Table of Contents

More information

INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1

INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1 INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA FOREWORD Thank you for purchasing the RS-BA. The RS-BA is designed to remotely control an Icom radio through a network. This instruction manual contains

More information

23070 / Digital Camera Owner s Manual

23070 / Digital Camera Owner s Manual 23070 / 23072 Digital Camera Owner s Manual 2007 Sakar International, Inc. All rights reserved. 2007 Crayola Windows and the Windows logo are registered trademarks of Microsoft Corporation. All other trademarks

More information

MPR kHz Reader

MPR kHz Reader MPR-5005 Page 1 Doc# 041326 MPR-5005 125kHz Reader Installation & Operation Manual - 041326 MPR-5005 Page 2 Doc# 041326 COPYRIGHT ACKNOWLEDGEMENTS The contents of this document are the property of Applied

More information

AUTOTUNE USER GUIDE. R8000 Series Communications System Analyzer. Motorola MOTOTRBO Portable Motorola MOTOTRBO Mobile

AUTOTUNE USER GUIDE. R8000 Series Communications System Analyzer. Motorola MOTOTRBO Portable Motorola MOTOTRBO Mobile R8000 Series Communications System Analyzer AUTOTUNE USER GUIDE Motorola MOTOTRBO Portable Motorola MOTOTRBO Mobile Freedom Communication Technologies 2002 Synergy Blvd, Suite 200 Kilgore, Texas 75662

More information

RADITEK INC. code -g11

RADITEK INC. code -g11 code -g11 RM&C Software Remote Monitoring & Control for Desktop Installation and Operation Manual Rev. 17 Sep 2011 TABLE OF CONTENTS CHAPTER 1... 1 GENERAL INFORMATION... 1 1.1 INTRODUCTION... 1 1.2 SYSTEM

More information

MAXI Remote Location Kit MRLK 900 Installation and Configuration Manual

MAXI Remote Location Kit MRLK 900 Installation and Configuration Manual MAXI Remote Location Kit MRLK 900 Installation and Configuration Manual 01/18 635079 Table of Contents Introduction... 3 Materials Included... 3 Setup Overview... 4 Radio Configuration Overview:... 4 FreeWaveTool

More information

Dual-band radio transmitter T10, Т10С T10U, T10UC

Dual-band radio transmitter T10, Т10С T10U, T10UC Dual-band radio transmitter T10, Т10С T10U, T10UC (v.yymmdd) Installation manual www.trikdis.com 1 Contents Safety requirements... 3 Transmitter function... 3 Operation... 3 Outside view... 4 Installation...

More information

TV SIGNAL LEVEL METER USER MANUAL

TV SIGNAL LEVEL METER USER MANUAL TV SIGNAL LEVEL METER USER MANUAL - 0 - 1. Overview (1) (1) RF input (2) (3) A D E B C (2) Speaker (3) LCD display (4) Charger indicator (5) RS232 communication port (6) DC-IN port F G A. The battery icon

More information

Disclaimers. Important Notice

Disclaimers. Important Notice Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,

More information

Signal Generators for Anritsu RF and Microwave Handheld Instruments

Signal Generators for Anritsu RF and Microwave Handheld Instruments Measurement Guide Signal Generators for Anritsu RF and Microwave Handheld Instruments BTS Master Spectrum Master Tracking Generator Option 20 Vector signal Generator Option 23 Anritsu Company 490 Jarvis

More information

Micromate User Manual

Micromate User Manual Microcoin Table of Contents Page Essential Information 2 1.0 Connection and Configuration 3 1.1 Connection 3 1.2 Switch On 4 1.3 Configuration for Use 4 2.0 Check the Configuration of a Validator 5 2.1

More information

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL The features mentioned in this Advanced OT-1000-HH Manual can be accessed only with the optional OT-NEC-A, Network Element

More information

Kenwood TH-G71 Protocol Specification

Kenwood TH-G71 Protocol Specification Kenwood TH-G71 Protocol Specification This document describes the serial commands used to program and control the TH-G71 radio via its serial port. Some of this data was initially based on information

More information

RigExpert TI-7 USB Transceiver Interface User s manual

RigExpert TI-7 USB Transceiver Interface User s manual RigExpert TI-7 USB Transceiver Interface User s manual Please read this manual before attempting to use the RigExpert TI-7 device. - - 2 - Table of contents 1. What is a RigExpert TI-7?... 4 2. Specifications...

More information

Ordering Guide. VRX1000 Vehicle Radio Extender. 8A087X01 Revision 2.9. December 19, 2018

Ordering Guide. VRX1000 Vehicle Radio Extender. 8A087X01 Revision 2.9. December 19, 2018 Ordering Guide VRX1000 Vehicle Radio Extender 8A087X01 Revision 2.9 Contents Revision History... 3 Ordering Instructions PLEASE READ CAREFULLY... 4 Important Notes... 5 1. Mobile Radio Type... 6 2. VRX1000

More information

FOD Transmitter User s Guide

FOD Transmitter User s Guide FOD Transmitter User s Guide Rev 4, 07/18/2013 AVID Technologies, Inc. FOD Transmitter User s Guide Page 2 General Description The AVID FOD (Foreign Object Detection) Transmitter is a standard WPC Qi V1.1

More information

Effective Training Inc. Aug 2009

Effective Training Inc. Aug 2009 User Manual 1 Trademark Acknowledgements The GD&T Trainer Professional Edition is a trademark of Effective Training Inc. This product is authored using Toolbook Instructor from SumTotal Systems and Flash

More information

Antenna and Propagation

Antenna and Propagation Antenna and Propagation This courseware product contains scholarly and technical information and is protected by copyright laws and international treaties. No part of this publication may be reproduced

More information

RMV25 / RMV50 RMU25 / RMU45

RMV25 / RMV50 RMU25 / RMU45 RMV25 / RMV50 RMU25 / RMU45 Owner's Manual TABLE OF CONTENTS INTRODUCTION... 3 FCC Requirements... 3 SAFETY WARNING INFORMATION... 3 CONTROLS and INDICATORS... 5 FRONT PANEL... 5 LCD Icons and Indicators...

More information

Technical Note #15. Radio Frequency Modems. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

Technical Note #15. Radio Frequency Modems. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home 1 of 5 GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home GE Power Management Control System Description Software Hardware Operation Product Support Operator Interfaces F A Q s App

More information

SRT Marine Technology. LD2342 V1.4 Page 1 of 22

SRT Marine Technology. LD2342 V1.4 Page 1 of 22 LD2342 V1.4 Page 1 of 22 LD2342 V1.4 Page 2 of 22 2 LD2342 V1.4 Page 3 of 22 GENERAL WARNINGS All marine Automatic Identification System (AIS) units utilise a satellite based system such as the Global

More information

CAD-MF. PC-Based Multi-Format ANI & Emergency ANI Display Decoder. Manual Revision: Covers Firmware Revisions: CAD-MF: 1.

CAD-MF. PC-Based Multi-Format ANI & Emergency ANI Display Decoder. Manual Revision: Covers Firmware Revisions: CAD-MF: 1. CAD-MF PC-Based Multi-Format ANI & Emergency ANI Display Decoder Manual Revision: 2010-05-25 Covers Firmware Revisions: CAD-MF: 1.0 & Higher Covers Software Revisions: CAD: 3.21 & Higher Covers Hardware

More information

User Configurable POSITION 303 DATA OUTPUT 450 HEADING 910

User Configurable POSITION 303 DATA OUTPUT 450 HEADING 910 WinFrog Device Group: Device Name/Model: Device Manufacturer: Device Data String(s) Output to WinFrog: WinFrog Data String(s) Output to Device: WinFrog Data Item(s) and their RAW record: GPS TRACS TDMA

More information

TurboTuner-2 Automatic Screwdriver Antenna Controller Model YTT-450 For: Yaesu FT-450/950/ FTDX-1200/3000 User s Manual TennaTronix.

TurboTuner-2 Automatic Screwdriver Antenna Controller Model YTT-450 For: Yaesu FT-450/950/ FTDX-1200/3000 User s Manual TennaTronix. TurboTuner-2 Automatic Screwdriver Antenna Controller Model YTT-450 For: Yaesu FT-450/950/ FTDX-1200/3000 User s Manual TennaTronix.com Congratulations on purchasing the TurboTuner-2 Automatic Screwdriver

More information

JEM Radio II Operation Guide. Manual P/N M Victor Place Colorado Springs, Colorado

JEM Radio II Operation Guide. Manual P/N M Victor Place Colorado Springs, Colorado JEM Radio II Manual P/N M09999-999 2115 Victor Place Colorado Springs, Colorado 80915 800.284.0399 www.jemcom.com Table of Contents Display... 3 Channel Entry... 4 Shortcuts... 4 Text Messages... 4 Buttons...

More information

AT-5888UV Programming Software for the AnyTone AT-5888UV

AT-5888UV Programming Software for the AnyTone AT-5888UV AT-5888UV Programming Software for the AnyTone AT-5888UV Memory Channel Functions Memory Types Memories Limit Memories Hyper Memory 1 Hyper Memory 2 Receive Frequency Transmit Frequency Offset Frequency

More information

AT-D868UV CodePlug Programming Guide

AT-D868UV CodePlug Programming Guide INTRODUCTION The AnyTone D868UV radio is a VHF and UHF radio with both Digital DMR (Tier I and II) and Analog capabilities. It offers a total of 4,000 channels (Analog and Digital) and up to 130,000 contacts,

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL PREFACE This installation & operation manual is intended as an instruction manual for trained person who is in charge of installation, maintenance, repair, etc. Before installation

More information

etatronix PMA-3 Transmitter Tester Manual

etatronix PMA-3 Transmitter Tester Manual etatronix PMA-3 Transmitter Tester Manual TxTester_Manual_rev1.02.docx 1 Version Version Status Changes Date Responsible 1 Release Initial release 01. Apr. 2015 CW 1.01 Release Updated Figure 4 for better

More information

Schlage Control Smart Locks

Schlage Control Smart Locks Schlage Control Smart Locks with Engage technology User guide Schlage Control Smart Locks with Engage technology User Guide Contents 3 Warranty 4 Standard Operation 4 Operation from the Inside 4 Operation

More information

M F TYPE S R-SETUP. Setup Software

M F TYPE S R-SETUP. Setup Software M0006935F TYPE S R-SETUP Setup Software Preface This user s manual explains the use and specifications of the Setup Software for AC servo amplifier R series. Notifications on this User s Manual: To completely

More information

Agilent Technologies. E8257D/67D, E8663D PSG Signal Generators. Key Reference. Agilent Technologies

Agilent Technologies. E8257D/67D, E8663D PSG Signal Generators. Key Reference. Agilent Technologies Agilent Technologies E8257D/67D, E8663D PSG Signal Generators Key Reference Agilent Technologies Notices Agilent Technologies, Inc. 2006-2010 No part of this manual may be reproduced in any form or by

More information