DENSITY TRANSMITTERS FOR DENSITY AND CONCENTRATION APPLICATIONS. Accuracy ± g/cm 3 (± 0.1 Brix) Range 0.5 g/cm 3 5 g/cm 3

Size: px
Start display at page:

Download "DENSITY TRANSMITTERS FOR DENSITY AND CONCENTRATION APPLICATIONS. Accuracy ± g/cm 3 (± 0.1 Brix) Range 0.5 g/cm 3 5 g/cm 3"

Transcription

1 Accuracy ±.4 g/cm 3 (±. Brix) DENSITY TRANSMITTERS FOR DENSITY AND CONCENTRATION APPLICATIONS Range.5 g/cm 3 5 g/cm 3 Direct density or concentration readout in engineering units such as g/cm 3, Kg/m 3, Specific Gravity, Brix, Baume, Plato, INPM, GL, API, % Solids, % Concentration, etc. Integral Temperature Sensor Suitable for Tank and Pipe Applications Factory Calibration and Self Calibration Advanced Diagnostics Largest Library of Function Block Execution Capacity Industrial and Sanitary Models Instantiable Function Blocks Supported by DD, EDDL and FDT/DTM Density, Concentration and Temperature in three Analog Input Blocks

2 Features Accuracy ±.4 g/cm³ (±. Brix); Temperature compensation; Range.5 g/cm³ - 5 g/cm³; Standard industrial and sanitary process connection; Digital LCD indicator; Direct density or concentration readout in engineering units; Suitable for dynamic and static liquids; Two wire loop powered; Several different wetted materials; Single integrated unit without moving parts; Factory calibration and Self calibration; In field re-calibration: No standard reference required; No lab calibration required; No process shutdown. Continuous/Self diagnostics; Weather proof, explosion proof and intrinsically safe; The control strategy is built from direct instantiation and deletion of function blocks; Configuration and Parameterization all through open and interoperable configuration tools available in the market, e.g., based on PC or PCMCIA Cards or operations by the local adjustment switches (should be used with a LCD display); Use of the Analog Input function; Totally digital; including sensor, electronics and communication; Configurable Local Adjustment (Foundation fieldbus TM and PROFIBUS PA); Easy firmware upgrade (via Flash Memory Interface) for Foundation fieldbus TM and PROFIBUS PA; Easy maintenance; Three technology options: HART, Foundation fieldbus TM, PROFIBUS PA. HART - 4 to ma Multi-drop operation mode; Supports DTM and EDDL. Foundation fieldbus TM 7 different types of function blocks for control strategies and advanced diagnostics; Up to function blocks; Two analog inputs: density and concentration or temperature; Execution of up to 3 external links (9 Publisher and Subscriber); ma consumption; Dynamic block instantiation improves interchangeability; Foundation fieldbus TM registered and ITK approved; MVC (Multivariable Container) enabled. PROFIBUS PA ma consumption; Three Function blocks for analog inputs: density, concentration and temperature; Integrated to Simatic PDM; Supports DTM and EDDL; Profile 3. improves interchangeability.

3 Functional Description The DT3 Touché Intelligent Density Transmitter is an instrument developed for the continuous, online measurement of liquid density and concentration, directly in the industrial process. Its pioneer technology consists of a capacitive type differential pressure sensor coupled to a pair of pressure repeaters immersed in the process. A temperature sensor located between the two pressure repeaters is used to compensate the temperature variations in the process fluid. A dedicated software, by means of an algorithm, calculates the fluid density. Depending on the industrial process, density may be expressed in g/cm 3, Kg/m 3, lb/ft 3, Specific Gravity, Brix degree, Gay-Lussac degree, Baumé degree, Plato degree, INPM degree, API degree, Solids %, Concentration %, etc. Designed for process control applications, these -wire transmitters generate a signal proportional to the concentration/density. Digital communication for remote calibration and monitoring is also provided. Block Diagram Sensor Assembly Main Processor Assembly PROCESS ELECTRONIC PCB PROBE TEMPERATURE COMPENSATION ALGORITHM P ELECTRONIC CONVERTER TEMPERATURE CONVERTER PROCESSING UNIT RANGES SPECIAL FUNCTIONS OUTPUT CONTROL SERIAL COMMUNICATION HART PROTOCOL CONVERTER D/A MODEM BELL INPUT/OUTPUT STAGE SIGNAL CONDITIONER 4-mA / HART / Foundation fieldbus / PROFIBUS PA LCD Indicator Assembly P E PROM * SENSOR DATA DISPLAY CONTROLLER DISPLAY DIGITAL 3

4 Density Transmitters Types The DT3 Touché is available in two models: DT3I (Industrial Model) for general purpose; DT3S (Sanitary Model) for food and other applications where sanitary connections are required. Both models have two mounting types: top mounting (straight type) and side mounting (curved type). Installation may be done either in open or pressurized tanks, or directly in pipes since the DT3 is suitable for dynamic and static fluids. The Sanitary model that meet 3-A Certification (Authorization N 399) uses a Tri-Clamp connection to allow a quick and easy connection and disconnection from the process. The wetted surface finish is polished and then is free of crevices where food or bacteria can be collected. 3A is the most widely accepted sanitary standard in the food, drug and beverage industry. Applications Sugar and Alcohol Processing Plants: Brix of the sugarcane juice, brix of the must, brix of the syrup, brix of the molasses, brix of the solved juice, calcium solution of the Baumé, interface level of the hexane cycle, lime density, INPM degree of the hydrated alcohol, INPM degree of the anhydrid alcohol, etc. Dairy Product Industries: Condensed milk, Lactose, Yogurt, Cream cheeses, Lactic Acids, etc. Food Industry: Vegetable oils, miscellaneous extractions, fruit syrup, starch dilution, glucose, jams, jellies, sweets, honey, tomato pulp, citrus juices, etc. Pulp and Paper Industries: Black liquor, green liquor, white liquor, red liquor, caustic soda concentration, ash dilution, talc dilution, pulp dilution, ink concentration, potassium hydroxide, etc. Beverage Industry: Beer (Plato degree in the fermentation process) Soft Drinks (brix of the liquid sugar, etc.), liquors, wines, soluble coffee, malt, tequila, etc. Chemical Industry: Acids, concentration/mixture, caustic soda, glycol, salt solution, detergent, toluene, urea, potassium, etc. Mining Slurries: Mineral pulp, extraction of thins, flotation, thickening, acid concentration, starch dilution, scrapers, lime mud. Petrochemical Industry: Gas washing water, lubricant oils, aromatic extraction, fuel oils, gasoline, kerosene, water/oil interface level. 4

5 Parameterization and Diagnostics DT3 Series are available in three different technologies: HART (DT3), Foundation fieldbus TM (DT3) and PROFIBUS PA (DT33). These instruments can be configured with Smar software and other manufacturers configuration tools. Local adjustment is available in DT3 and DT33. For these models is possible to configure concentration adjust, self-calibration, direct density or concentration readout in engineering units and other control functions using the magnetic screwdriver. Smar has developed Asset View, which is a user-friendly Web Tool that can be accessed anywhere and anytime using an Internet browser. It is designed for management and diagnostics of field devices to ensure reactive, preventive, predictive and proactive maintenance. HART - DT3 DT3 (HART protocol) can be configured by: Smar CONF4 for Windows and UNIX; Smar DDCON for Windows and UNIX; Smar HPC3 for several models of Palms*; Other manufacturers configuration tools based on DD (Device Description) or DTM (Device Type Manager), such as AMS TM, FieldCare TM, PACTware TM, HHT75 and HHT375, PRM Device Viewer. For DT3 management and diagnostics, Asset View ensures continuous information monitoring. *Requires the HPI3 or HPI3 interface. Foundation fieldbus TM - DT3 DT3 utilizes the Foundation fieldbus TM H protocol, an open technology that allows any H enabled configuration tool to configure this device. Syscon3 (System Configuration Tool) is a software tool used to configure, maintain and operate the field devices. Syscon offers efficient and friendly interaction with the user, using Windows NT version 4. or later, Windows and Windows XP. Seventeen different types of function blocks are supported, and up to function blocks can be running simultaneously. Maintenance procedures with Asset View diagnostics and status information from Foundation fieldbus TM result in a safer plant with longer availability. Configuration tools such as AMS TM and HHT375 can configure DT3 devices. DD (Device Description) and CF (Capability File) files can be downloaded at either the Smar or Fieldbus Foundation website. DT3 supports complex strategies configurations due to the high capacity and variety of dynamic instantiable function blocks. DT33 (PROFIBUS PA protocol) can be configured using Simatic PDM and by the FDT (Field Device Tool) and DTM (Device Type Manager) concept tools, such as FieldCare TM and PACTware TM. It can also be integrated by any PROFIBUS System using the GSD file. PROFIBUS PA also has quality and diagnostic information, improving plant management and maintenance. PROFIBUS PA - DT33 5

6 Applications HART - DT3 Power Supply Interface HI 5 Control Painel Field FY3 FV DT3 DIT Foundation fieldbus TM - DT3 BT3 Bus Terminator Solution Density DT3 Power Supply + Bus Impedance FY3 FV DT3 DIT FY3 HSE Link Device BT3 Bus Terminator PROFIBUS - DT33 BT3 Bus Terminator BT3 Bus Terminator Power Supply FY33 FV Solution Density DT33 DF73 DT33 DIT FY33 Profibus DP Master 6

7 Technical Characteristics Functional Specifications Output and Communication Protocol Power Supply/ Current Consumption Indicator Hazardous Area Certifications Other Certification ero and Span Adjustments Failure Alarm (Diagnostics) Temperature Limits Turn-on Time Configuration Static Pressure Limit Humidity Limits Damping Adjustment HART : Two-wire, 4- ma with super-imposed digital communication (HART Protocol). Foundation fieldbus TM and PROFIBUS PA: Digital only. Complies with IEC 658-: (H): 3.5 kbit/s voltage mode, bus powered. HART : to 45 Vdc. Foundation fieldbus TM and PROFIBUS PA: Bus powered: 9 to 3 Vdc. Quiescent current consumption: ma. 4½-digit numerical and 5-character alphanumerical LCD indicator (optional). HART, Foundation fieldbus TM and PROFIBUS PA: Explosion proof, weather proof, intrinsically safe, CEPEL, Dekra/EXAM, FM, NEMKO and NEPSI. Foundation fieldbus TM and PROFIBUS PA: FISCO Field Device Ex ia IIC T4 (CEPEL, Dekra/EXAM, NEPSI) and FNICO Field Device Ex nl IIC T4 (CEPEL, Dekra/EXAM). HART, Foundation fieldbus TM and PROFIBUS PA: 3A Sanitary Standard. Noninteractive, via digital communication or local adjustment. Detailed diagnostics through communication for all protocols. HART : In case of sensor or circuit failure, the self diagnostics drives the output to 3.6 or. ma, according to the user s choice. Foundation fieldbus TM : For sensor circuit failures, events are generated and status is sent to link outputs. Detailed diagnostics are available in the contained parameters. PROFIBUS PA: For sensor or circuit failures, status is sent to output parameters. Detailed diagnostics are available in the contained parameters. Ambient: -4 to 85 C (-4 to 85 F) Process: - to 5 C (-4 to 3 F) Storage: -4 to C (-4 to F) Digital Display: - to 6 C (4 to 4 F) HART : Performs within specifications in less than 5 seconds after power is applied to the transmitter. Foundation fieldbus TM and PROFIBUS PA: Performs within specifications in less than seconds after power is applied to the transmitter. HART : By digital communication (HART protocol) using the configuration software CONF4, DDCON (for windows), HPC3 or HPC4 (for Palms). It can also be configured using DD and FDT/DTM tools. Foundation fieldbus TM and PROFIBUS PA: Basic configuration may be done using the local adjustment magnetic tool if device is fitted with display. Complete configuration is possible using configuration tools. 7 MPa (7 kgf/cm²) (5 psi). to % RH. to 3 seconds in addition to intrinsic sensor response time (. s) via digital communication. 7

8 Technical Characteristics Performance Specifications Reference Conditions Accuracy Stability (for months) Ambient Temperature Effect (per C) Static Pressure Effect Power Supply Effect Mounting Position Effect Electro-Magnetic Interference Effect Temperature of 5 C (77 F), atmospheric pressure, power supply of 4 Vdc, silicone oil fill fluid, isolating diaphragms in 36L SST and digital trim equal to lower and upper range values. For range : ±.4 g/cm³ (±. Bx) For range : ±.7 g/cm³ For range 3: ±.6 g/cm³ Linearity, hysteresis and repeatability effects are included. For range :. x -3 g/cm³ For range :.83 x -3 g/cm³ For range 3:.5 x -3 g/cm³ For range :.3 x -3 g/cm³ For range :.3 x -3 g/cm³ For range 3:.4 x -3 g/cm³ ero Static Pressure For range :. x -3 g/cm³ For range :.4 x -3 g/cm³ For range 3:.7 x -3 g/cm³ ±.5% of calibrated span per volt. It can be eliminated after installation. No span effect. Designed to comply with IEC 636-:6, IEC :6, IEC 6-6-4:6 and IEC 6-6-:5. Physical Specifications Electrical Connection Process Connection Wetted Parts Nonwetted Parts Mounting Approximate Weights / - 4 NPT M X.5 PG 3.5 DIN Industrial Model: 36 SST Flange ANSI B Sanitary Model: 34 SST Tri-clamp 4. Isolating Diaphragms: 36L SST or Hastelloy C76. Wetted O-Rings (For Sanitary Model): Buna N, Viton or Teflon. Electronic Housing: Injected aluminum with polyester painting or 36 SST. Complies with NEMA 4X, IP66/68 W. Fill Fluid: Silicone (DC/, DC74), Glycerin and Water, Neobee M Propylene Glycol. Cover O-Rings: Buna N. Identification Plate: 36 SST. Side or top mounted. 8 kg (8 lb) Sanitary Model. kg (6 lb) Industrial Model. Viton and Teflon are trademarks of E. I. DuPont de Nemours & Co. HART is a trademark of HART Communication Foundation. Foundation is a trademark of Fieldbus Foundation. Profibus is a trademark of Profibus International. This product is protected by US patent numbers 6,34,9 and D439,855. 8

9 Ordering Code - Industrial Model MODEL DT3 I DT3 I DT33 I INDUSTRIAL CONCENTRATION/DENSITY TRANSMITTER HART & 4- ma Foundation fieldbus TM PROFIBUS PA Range Minimum Span H I U X to to to.8 g/cm³.5 g/cm³ 5. g/cm³ Wetted Parts Material.5 g/cm³.5 g/cm³.5 g/cm³ Hastelloy C76 / Hastelloy C76 36L SST / 36L SST Hastelloy C76 / 36L SST 36L SST / 36L SST with plated TEFEL (ETFE) Others - Specify Fill Fluid N D S G T Neobee- M Propylene Glycol - Food Grade DC-74 Silicone Oil DC / Silicone Oil Glycerin and Water - Food Grade Syltherm 8 Others - Specify Local Indicator Without Indicator With Digital Indicator Electrical Connection 3 ½ - 4 NPT (4) / - 4 NPT X 3/4 NPT (AI 36) - With Adapter (5) / - 4 NPT X 3/4 BSP (AI36) - With Adapter (6) / - 4 NPT X / BSP (AI 36) - With Adapter (6) Mounting Top Side A 3 C Note: For the concentration units: o Brix, o Plato, o INPM, o GL and o Baumé, specify code. Process Connection Size, Rating and Standard 4" 5# ANSI B-6.5 4" 3# ANSI B-6.5 4" 6# ANSI B-6.5 DN PN5/4 DIN 56 - FORM D Others - Specify Continues Next Page A B M X.5 (7) PG 3.5 DIN (7) Others Specify DT3I I S 5 * TYPICAL MODEL NUMBER DT3I I S 5 * DT33I I S * Leave it blank for no optional items. 5 * 9

10 Ordering Code - Industrial Model MODEL INDUSTRIAL CONCENTRATION/DENSITY TRANSMITTER (CONTINUATION) I I4 I5 I6 I7 IE Identification Plate FM: XP, IS, NI, DI EXAM ( DMT): EX-IA; NEMKO: EX-D CEPEL: EX-D, EX-IA Without Certification EXAM (DMT) GRUPO I, M EX-IA NEPSI: EX-IA Housing Material () () H H H H3 H4 Aluminum (IP/Type) 36 SST (IP/Type) Aluminum for Saline Atmosphere (IPW/TypeX) (3) 36 SST for Saline Atmosphere (IPW/TypeX) (3) Copper Free Aluminum (IPW/TypeX) (3) Tag Plate J J J With Tag Blank User's Specification Display Unit Y Y Y Y3 Y4 Y5 Y6 YU Percentage : Current I (ma) : Density/Concentration (Eng. Unit) : Temperature (Temperature) : Current I (ma) : Density/Concentration (Eng. Unit) : Temperature (Temperature) : User's Specification Painting P P3 P4 P5 P8 P9 PC Gray Munsell N 6,5 Black Polyester White Epoxy Yellow Polyester Without Painting Blue Safety Epoxy Electrostatic Painting Blue Safety Polyester Electrostatic Painting Optional Item (*) Special Options DT3I-IS--5 DT3I-IS--5 DT33I-IS--5 I6 H J Y P * I6 H J P * I6 H J P * TYPICAL MODEL NUMBER * Leave it blank for no optional items. Optional Items Diaphragm Thickness Strengthening of the Probe Mounting Position N - Standard N -. mm R - with strengthening of the probe E - reverse position Notes () IPX8 tested in meters of water column for 4 hours. (4) Certified for use in Explosive Atmosphere (CEPEL, FM, CSA, NEPSI, NEMKO and EXAM). () Ingress Protection: (5) Certified for use in Explosive Atmosphere (CEPEL and CSA). Product CEPEL NEMKO / EXAM FM CSA NEPSI (6) Options not certified for Explosive Atmosphere. (7) Certified for use in Explosive Atmosphere (CEPEL, NEPSI, NEMKO and EXAM). DT3X IP66/68/W IP66/68/W Type 4X/6 Type 4X IP67 (3) IPW / TypeX tested for hours according to NBR 894 / ASTM B 7 standard.

11 Ordering Code - Sanitary Model MODEL DT3 S DT3 S DT33 S SANITARY CONCENTRATION/DENSITY TRANSMITTER HART & 4- ma Foundation fieldbus TM PROFIBUS PA Range Minimum Span H I U to to to.8 g/cm³.5 g/cm³ 5. g/cm³.5 g/cm³.5 g/cm³.5 g/cm³ Wetted Parts Material Hastelloy C76 36L SST Probe in 36L SST and Diaphragms in Hastelloy C76 Others Specify N D S G T Fill Fluid Neobee- M Propylene Glycol - Food Grade (8) DC-74 Silicone Oil DC / Silicone Oil Glycerin and Water - Food Grade Syltherm 8 Others Specify Local Indicator Without Indicator With Digital Indicator 3 Electrical Connection ½ - 4 NPT (4) / - 4 NPT X 3/4 NPT (AI 36) - With Adapter (5) / - 4 NPT X 3/4 BSP ( AI36) - With Adapter (6) / - 4 NPT X / BSP (AI 36) - With Adapter (6) Mounting Top Side J Process Connection Tri-clamp - 4" 3# (8) Others Specify B V T Wetted O-Rings Material Buna-N (8) Viton (8) Teflon (8) Others - Specify Tank Adapter Without Tank Adapter (Supplied by Customer) With Tank Adapter 36 SST Tri-Clamp Without Tri-clamp With Tri-clamp in 34 SST Continues Next Page Note: For the concentration units: o Brix, o Plato, o INPM, o GL and o Baumé, specify code. A B M X.5 (7) PG 3.5 DIN (7) Others - Specify DT3S I N J B * TYPICAL MODEL NUMBER DT3S I N J B * DT33S I N J B * Leave it blank for no optional items. *

12 Ordering Code - Sanitary Model MODEL SANITARY CONCENTRATION/DENSITY TRANSMITTER (CONTINUATION) Identification Plate I FM: XP, IS, NI, DI I4 EXAM ( DMT): EX-IA; NEMKO: EX-D I5 CEPEL: EX-D, EX-IA I6 Without Certification I7 EXAM (DMT) GRUPO I, M EX-IA IE NEPSI: EX-IA Housing Material () () H H H H3 H4 Aluminum (IP/Type) 36 SST (IP/Type) Aluminum for Saline Atmosphere (3) (IPW/TypeX) 36 SST for Saline Atmosphere (3) (IPW/TypeX) Copper Free Aluminum (3) (IPW/TypeX) Tag Plate J J J With Tag Blank User's Specification Display Unit Y Y Y Y3 Y4 Y5 Y6 YU Percentage : Current I (ma) : Density/Concentration (Eng. Unit) : Temperature (Temperature) : Current I (ma) : Density/Concentration (Eng. Unit) : Temperature (Temperature) : User's Specification Painting P P3 P4 P5 P8 P9 PC Gray Munsell N 6,5 Black Polyester White Epoxy Yellow Polyester Without Painting Blue Safety Epoxy Electrostatic Painting Blue Safety Polyester Electrostatic Painting Optional Item (*) Special Options DT3S-IN--JB DT3S-IN--JB DT33S-IN--JB I6 H J Y P * I6 H J P * I6 H J P * TYPICAL MODEL NUMBER * Leave it blank for no optional items. Notes () IPX8 tested in meters of water column for 4 hours. (5) Certified for use in Explosive Atmosphere (CEPEL and CSA). () Ingress Protection: (6) Options not certified for Explosive Atmosphere. (7) Certified for use in Explosive Atmosphere (CEPEL, NEPSI, NEMKO and EXAM). Product CEPEL NEMKO / EXAM FM CSA NEPSI (8) Compliant with 3A-743 standard for food and other applications where sanitary connections DT3X IP66/68/W IP66/68/W Type 4X/6 Type 4X IP67 are required. (3) IPW / TypeX tested for hours according to NBR 894 / ASTM B 7 standard. (4) Certified for use in Explosive Atmosphere (CEPEL, FM, CSA, NEPSI, NEMKO and EXAM). - Neobee MO Fill Fluid - Finishing wet Face:.8 µm Ra (3 µ" AA) - Wet O-Ring: Viton Teflon and Buna-N

13 Dimensional Drawings Industrial Model - 5 mm Dimensions are millimeters (inches) 365 (4.37) 45 (9.65) 46 (5.75) 83 (3.7) 89 (3.5) 6 (.4) Electrical Connection Flanged Connection Electrical Connection 4 Flaged Connection 5 (9.68) 73 (8.75) 65 (5.59) 8 (.) Side Mounting Type Top Mounting Type Sanitary Model - 5 mm 3 (9.5) 93 (.53) 63 (.48) 83 (3.7) Electrical Connection 89 (3.5) 45 (9.65) 89 (3.5) 3 (4.45) 46 (5.75) 4 Tri-Clamp Connection Electrical Connection 8 (.3) (4.7) 4 Tri-Clamp Connection 76 (3.) 76 (3.) 5 (9.68) 65 (5.59) 8 (3.9) 5 (9.68) 7 (4.6) Side Mounting Type Top Mounting Type 3

14 Dimensional Drawings Industrial Model - 8 mm 83 Electrical Connection Flange Connection 4" RF ANSI B6,5 5# 5, Side Mounting Type Top Mounting Type 4

15 4 - ma Outputs Fiber Optic Ring 5 rete isc e In D iscret D t Ou H I.S. FOUNDATION TM DC3 (Remote I/O) DF 4 - ma Inputs Channel Intrinsic Safety Barrier FOUNDATION TM FISCO Communication Server Channel 8 DFI3 Redundant Controller Communication Server All-in-one Station Fieldbus PA Maintenance and Asset Management DP DFI3 PROFIBUS DP and PA et ern Eth Maintenance DFI3 Redundant Controller Communication Server Operation HI3 HART/FOUNDATION TM Engineering DFI3 DeviceNet 4 - ma Router or Firewall Corporate Network Internet I.S. Discrete I/O DFI3 (Cotroller with I/O modules) 4 - ma I.S. Discrete I/O DFI3 AS-i Auto Tuning Advanced Control - MES (Manufacturing Execution System) - ERP (Enterprise Resource Planning) - CRM (Customer Relationship Management Communication Server Alarm and Asset Management Maintenance Modbus TCP Modbus RTU Matrix Printer Package Units Legacy Systems CLP F&G ESD Internet Communication Server Laser Printer Server Server System3 Architecture

16 Main Smar Products Pressure Pressure, Level and Flow Level Density/Concentration 4- ma LD9 LD9 LD. LD3 LD4 RD4 DT3 LD9 LD3 DT3 LD93 LD33 DT33 Pressure Transmitter Gauge Economic Capacitive Pressure Transmitter Pressure Transmitter Pressure Transmitter with high performance Level Transmitter Intelligent Density / Concentration Transmitter Position FY3 FY3 TP3 FY3 FY4 FY3 TP3 FY33 FY33 TP33 Valve Positioner Valve Positioner with auto tuning Valve Positioner with remote sensor Position Transmitter Temperature Junction Box TT3 TT4 4- ma 4- ma TT3 TT33 TT4 Temperature Transmitter Panel Mounting Temperature Transmitter Head Mouting Temperature Transmitter 3 Ways Junction Box JM 4 Ways Junction Box JM4 Configurators Interfaces HART Configurator Interface CONF4 HART Configurator Interface DDCON HART Configurator for Palm HPC3 HART-RS3 Interface HI3 HART-USB Interface HI3 6

17 Main Smar Products Converters FP3 IF3 FI3 FP33 IF33 FI33 Fieldbus to Pneumatic Signal Converter Current to Fieldbus Converter Fieldbus to Current Converter HART / Fieldbus Interface HI3 HART / Current Converter HCC3 Controllers TM DeviceNet TM DeviceNet Programmable Logical Controller LC7 Digital Controller CD6Plus Systems Interface Universal Fieldbus DFI3 TM DeviceNet TM DeviceNet ProcessView Process Visualization Tool Studio3 System3 Management Tool AssetView On Line Plant Asset Management Tool TM DeviceNet Syscon System Configurator Equipment Database Plant Information Management LogicView IEC63 Programming Tool 7

18 smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: Copyright 6 - Smar International - all rights reserved. - November/

D E N S I T Y T R A N S M I T T E R S

D E N S I T Y T R A N S M I T T E R S Accuracy ± 0.0004 g/cm 3 (± 0. Brix) D E N S I T Y T R A N S M I T T E R S F O R D E N S I T Y A N D C O N C E N T R A T I O N A P P L I C A T I O N S Range 0.5 g/cm 3 5 g/cm 3 Direct density or concentration

More information

FOR DENSITY AND CONCENTRATION APPLICATIONS

FOR DENSITY AND CONCENTRATION APPLICATIONS HART 7/WirelessHART TM Protocol FOR DENSITY AND CONCENTRATION APPLICATIONS Accuracy ± 0.0004 g/cm 3 (± 0. Brix) Range 0.5 g/cm 3 5 g/cm 3 Direct Density or Concentration reading engineering units such

More information

интеллектуальные преобразователи температуры

интеллектуальные преобразователи температуры ± 0.02% Accuracy Single Unit and Several Options for Sensors and Connections Input Signal Isolation Advanced Diagnostics Supported by DD, EDDL and FDT/DTM Sensor Backup SIL 2 Safety Certified to IEC 61508

More information

GUIDED WAVE RADAR TRANSMITTER

GUIDED WAVE RADAR TRANSMITTER GUIDED WAVE RADAR TRANSMITTER FOR CONTINUOUS LEVEL MEASUREMENT Based on Time Domain Reflectometry (TRD) principle Not affected by density and/or temperature variations Not affected by viscosity, gravity,

More information

smar Main Smar Products Main Smar Products Controllers - Remote Input and Output Junction Box Didactic Products Didactic Plant

smar Main Smar Products Main Smar Products   Controllers - Remote Input and Output Junction Box Didactic Products Didactic Plant Junction Box JM1 Controllers - Remote Input and Output Didactic Products JM400 4-20 ma PD3 DF0 DC302 4-20 ma 3 Ways Junction Box Didactic Plant 4 Ways Junction Box CONF401 HSE Controller and WirelessHART

More information

smar Main Smar Products Main Smar Products Controllers - Remote Input and Output Didactic Products Junction Box 3 Ways Junction Box

smar Main Smar Products Main Smar Products   Controllers - Remote Input and Output Didactic Products Junction Box 3 Ways Junction Box Main Smar Products Main Smar Products Junction Box JM1 Controllers - Remote Input and Output Didactic Products JM400 4-20 ma PD3 DF0 DC302 4-20 ma 3 Ways Junction Box Didactic Plant 4 Ways Junction Box

More information

GUIDED WAVE RADAR TRANSMITTER

GUIDED WAVE RADAR TRANSMITTER GUIDED WAVE RADAR TRANSMITTER FOR CONTINUOUS LEVEL MEASUREMENT Based on Time Domain Reflectometry (TRD) principle Not affected by density and/or temperature variations Not affected by viscosity, gravity,

More information

SMART TEMPERATURE TRANSMITTERS. smar

SMART TEMPERATURE TRANSMITTERS. smar SMART TEMPERATURE TRANSMITTERS FEATURES Single unit accepts signal from: - Standart RTDs and Thermocouples - Single ended or differential sensing - mv signals from radiation pyrometers, load cells, etc.

More information

0 ~ 125 Pa to 0 ~ 25 MPa. 0 ~ 0.5 inh 2. 0 to 0 ~ 3600 psi. ± 0.075% Accuracy. 40:1 Rangeability. Wetted parts in 316 SS, Hastelloy

0 ~ 125 Pa to 0 ~ 25 MPa. 0 ~ 0.5 inh 2. 0 to 0 ~ 3600 psi. ± 0.075% Accuracy. 40:1 Rangeability. Wetted parts in 316 SS, Hastelloy 0 ~ 5 Pa to 0 ~ 5 MPa 0 ~ 0.5 inh 0 to 0 ~ 600 psi ± 0.075% ccuracy 0: Rangeability Wetted parts in 6 SS, Hastelloy Totally digital; including sensor, electronics and communication (Except LD90) Digital

More information

INTELLIGENT DENSITY TRANSMITTER

INTELLIGENT DENSITY TRANSMITTER OPERATION, MAINTENANCE AND INSTRUCTIONS MANUAL INTELLIGENT DENSITY TRANSMITTER MAY / 16 DT301 VERSION 2 D T 3 0 1 M E smar www.smar.com Specifications and information are subject to change without notice.

More information

FB DEVICES. конвертер 4-20 ма в Foundation Fieldbus цифровой протокол CURRENT TO FIELDBUS CONVERTER

FB DEVICES. конвертер 4-20 ма в Foundation Fieldbus цифровой протокол   CURRENT TO FIELDBUS CONVERTER FB DEVICES конвертер 4-20 ма в Foundation Fieldbus цифровой протокол www.esma-rt.ru IF302 CURRENT TO FIELDBUS CONVERTER Features 0.03% accuracy. Configuration through Fieldbus communication from a PC or

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

914DNS. Pressure and Density Transmitter. Features. 1 Datasheet 914DNS Pressure and density transmitter.

914DNS. Pressure and Density Transmitter. Features. 1  Datasheet 914DNS Pressure and density transmitter. Pressure and Density Transmitter Features Pressure and density transmitter. Low maintenance, quick calibration and configuration. Installation directly into pressurized vessels. HART technology provides

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging. ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging. Technical Specifications Data Communication Honeywell Bi-phase mark (Pos 2 = E and I) 1200 / 2400 bps > 1,500 V Full galvanic separation via isolating

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description

More information

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter Features Include Base accuracy : ±0.075% Span limits 0.134 to

More information

General Specifications

General Specifications General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties

More information

Level gauges Series LT Level indicator, switch and transmitter for liquids

Level gauges Series LT Level indicator, switch and transmitter for liquids Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance

More information

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Sarasota CM200 Sarasota HME900 Density Converter Electronics Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or

More information

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability. Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell Enraf s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It

More information

Series Smart Pressure Transmitter

Series Smart Pressure Transmitter www.tek-trol.com TEK-BAR 3100 Series Smart Pressure Transmitter www.tek-trol.com 2 Introduction The Tek-Bar series of smart transmitters have excellent stability, high accuracy and include features that

More information

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services. The SFC 1000 P2DAAA is a dual meter run bidirectional flow computer with a built in Rosemount 205 Multivariable Transmitter (DP, P, and TEMP) for the measurement of liquid & Gas products. Using orifice

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Applications Food and beverage industry Pharmaceutical industry Biotechnology industry Cosmetic industry Special Features Meets

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

A New Generation of Pressure Transmitters

A New Generation of Pressure Transmitters Fuji Electric Instrumentation & Control A New Generation of Transmitters ECNO : 610d A New addition to the FCX Family at the edge of Technology As a leader in the field of pressure measurement, Fuji Electric

More information

General Specifications

General Specifications General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22 Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)

More information

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters Data Sheet Brooks Industrial Brooks Digital Series Digital MFC's and MFM's Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters General Features:

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

Micro Motion Fork Density Meters

Micro Motion Fork Density Meters Micro Motion Fork Density Meters Direct insertion density meter Product Data Sheet PS-001485, Rev F November 2018 Rugged, accurate density and concentration measurement Continuous, real-time measurement

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output. Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision K FEATURES 4 to 20

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

A New Generation of Pressure Transmitters

A New Generation of Pressure Transmitters e-front runners A New Generation of Transmitters SeriesAII/CII ECNO : 610d A New addition to the FCX Family at the edge of Technology As a leader in the field of pressure measurement, Fuji Electric has

More information

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products Data sheet DS/AT100S-EN Rev. N AT100S Magnetostrictive Level Transmitter Sanitary magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* High Accuracy:.01% of Full Scale Superior

More information

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL. PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL www.unitorq.com UT-1000 Electro-Pneumatic Positioners Linear & Rotary Unmatched Stability in Tough Environments. UniTorq s advanced-control electro-pneumatic

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

SITRANS P. Transmitters for level. Introduction 1/42. Application

SITRANS P. Transmitters for level. Introduction 1/42. Application Introduction HK series S series Fig. / transmitters for level, with built-in analog indicator or digital display Application The transmitter with mounting flange measures the level of corrosive and non-corrosive

More information

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f A New Generation Of Pressure Transmitters -AII V5 ECNO : 610f A New Transmitter at the edge of Technology - - - - - -AII V5 2 - Approvals Fieldbus (FF) Protocols TM Hart /Fuji (bilingual) PROFIBUS The

More information

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology RefineME 4-IN-1 Measurement Inherent Accuracy ±1 mm API Temperature Corrected Volumes No Scheduled Maintenance or Recalibration

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor

More information

FOSTEN AUTOMATION SÉRIE F500-RD

FOSTEN AUTOMATION SÉRIE F500-RD FOSTEN AUTOMATION SÉRIE Guided Wave Radar Level Transmitter Guided wave radar level transmitter. Low maintenance, auto calibrated references. Easy installation, directly in tanks or auxiliary vessels.

More information

Alphaline Temperature Transmitters

Alphaline Temperature Transmitters Alphaline Temperature Transmitters Accepts RTD and thermocouple inputs Available with an integral meter Dual compartment housing provides the highest reliability in harsh industrial environments Offers

More information

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass

More information

Mass and Volume Flow Transmitter

Mass and Volume Flow Transmitter IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,

More information

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Indumax CLS50/CLS50D. Technical Information

Indumax CLS50/CLS50D. Technical Information Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D

More information

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm Electronic pressure measurement Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm WIKA data sheet PE 86.11 Applications Process engineering Pharmaceutical industry

More information

Magnetic Flowmeter Systems

Magnetic Flowmeter Systems Series 8700 Magnetic Flowmeter Systems THE 8700 SERIES... Model 8712 C/U - Easiest to use local operator interface and works with any manufacturer s flowtubes Model 8712H/8707 High-Signal System - Pulsed

More information

General Specifications

General Specifications General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products Data sheet DS/-EN Rev. T Magnetostrictive Level Transmitter External mounted magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* Designed to mount externally to K-TEK KM26

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA Easy integration to a Profibus DP network 5-year stability reduces maintenance costs Dual-compartment housing provides the highest reliability in harsh industrial environments 18-bit analog-to-digital

More information

SITRANS LR 300: High Performance Radar for Level Measurement

SITRANS LR 300: High Performance Radar for Level Measurement SITRANS LR 300: High Performance Radar for Level Measurement Reliable Measurement In Extreme Conditions SITRANS LR 300 delivers high performance level measurement at an affordable price for the chemical,

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

600T EN Series Pressure Transmitters. Specification sheet. Model 624ES gauge/absolute with direct mount seal for pulp & paper application

600T EN Series Pressure Transmitters. Specification sheet. Model 624ES gauge/absolute with direct mount seal for pulp & paper application Specification sheet 6T EN Series Pressure Transmitters Model 6ES gauge/absolute with direct mount seal for pulp & paper application Base accuracy : ±.7% Reliable inductive sensing system coupled with the

More information

Field IT 2600T Series Pressure Transmitters

Field IT 2600T Series Pressure Transmitters Data Sheet Field IT 2600T Series Pressure Transmitters Model 364GS Gauge Model 364AS Absolute standard overload Best in class total performance long term stability of 0.25% for 10 years base accuracy of

More information

DRS390 High stability, flange mounting

DRS390 High stability, flange mounting DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device

More information

Smart Displacer Level (Interface) Transmitter DLT100 Series

Smart Displacer Level (Interface) Transmitter DLT100 Series Smart Displacer Level (Interface) Transmitter DLT100 Series Equipped with FISHER FIELDVUE DLC3010 1 Introduction DLT100 series is Smart Displacer Level (Interface) Transmitter equipped with the original

More information

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization. Overview family are designed for measuring the flow of electrically conductive mediums. Benefits Easier commissioning of 5000, 6000, 6000 I All pulsed DC feature a unique SENSORPROM memory unit which stores

More information

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications 34-VF-03-04 September 2011 The High-Performance Solution The TWC 9000 is a universal coriolis meter converter suitable for a wide

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

MFC 400 Technical Datasheet

MFC 400 Technical Datasheet MFC 400 Technical Datasheet Signal converter for mass flowmeters High performance signal converter for all applications, developed acc. to IEC 61508, SIL 2/3 Stable in multi-phase applications due to Entrained

More information

Two-Wire Programmable Transmitter for:

Two-Wire Programmable Transmitter for: TM Smart Process Instrumentation Revision 2 Two-Wire Programmable Transmitter for: Industrial Thermocouple or RTD Temperature Measurements Highlights: Exceptional speed and accuracy Guaranteed measurement

More information

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span PERFORMANCE SPECIFICATIONS Reference Accuracy (1) Specifications Total Performance is based on combined errors of reference accuracy, ambient temperature effect, and static pressure effect. This product

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

OPTIMASS 1000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Head mounted Temperature Transmitter TF02/TF02-Ex

Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters ABB MEASUREMENT & ANALYTICS DATA SHEET TB8 -wire conductivity transmitters TB 8 -W I R E CON DUCT I VI T Y TR ANSMIT TE RS DS/ TB8 -E N RE V. H Measurement made easy Loop-powered transmitters that reduce

More information

SATRON VB Pressure Transmitter

SATRON VB Pressure Transmitter SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates

More information

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e A New Generation Of Pressure Transmitters -AII V5 ECNO : 610e A New Transmitter at the edge of Technology As a leader in the field of measurement, Fuji Electric has an installed base of more than 1 000

More information

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level measurement independent of changing process conditions (density, conductivity, temperature, pressure, ) Innovative

More information

Fieldbus Foundation India Committee & ISA South India Section

Fieldbus Foundation India Committee & ISA South India Section Fieldbus Foundation India Committee & ISA South India Section Fieldbus Foundation FFIC + ISA Fieldbus Foundation Conference-2010 Date Time Venue :6 th February, 2010 ( Saturday) : from 09:00 am to 05:30

More information

Radar Level Measurement micropilot FMR 130 for stilling wells

Radar Level Measurement micropilot FMR 130 for stilling wells Technical Information TI 258F/24/ae Radar Level Measurement micropilot FMR 130 for stilling wells Smart transmitter for non-contact measurement in metallic by-pass pipes and stilling wells Suitable for

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

STT 3000 Smart Temperature Transmitter

STT 3000 Smart Temperature Transmitter STT 3000 Smart Temperature Transmitter Foundation TM Fieldbus Model STT35F Introduction EN0I-6083 April 2009 Specification and Model Selection Guide Honeywell s microprocessor based STT35F Smart Temperature

More information

TS16 - Pre-Instructional Survey

TS16 - Pre-Instructional Survey TS16 - Pre-Instructional Survey Name: Date 1. What do you understand by the term Digital Transmitter? a. A transmitter that auto-configures and auto-calibrates itself. b. A transmitter that can be configured

More information