SEL-849. Motor Management Relay Quick-Start Guide

Size: px
Start display at page:

Download "SEL-849. Motor Management Relay Quick-Start Guide"

Transcription

1 SEL-849 Motor Management Relay Quick-Start Guide What s in the Box? SEL-849 Drill Template SEL-849 Relay Panel Drilling Template Manual CD (Optional) *PLS849-01*

2 Safety Information WARNING To avoid the risk of electrostatic discharge when using the SEL-3421 or SEL-3422 HMI, take one of the following precautions: 1) touch the front panel with an insulated object, 2) use ESD shoe covers to insulate shoes from the ground before touching the front panel, or 3) step on an insulated mat before touching the front panel. CAUTION To ensure proper safety and operation, the equipment ratings, installation instructions, and operating instructions must be checked before commissioning or maintenance of the equipment. The integrity of any protective conductor connection must be checked before carrying out any other actions. It is the responsibility of the user to ensure that the equipment is installed, operated, and used for its intended function in the manner specified in this manual. If misused, any safety protection provided by the equipment may be impaired. Dangers, Warnings, and Cautions The product manual contains instructions for putting the unit in service, information to facilitate maintenance, and complete product specifications. The product is not user-serviceable, and is not intended to be opened. For a complete list of warnings, please see the instruction manual. This manual uses three kinds of hazard statements, defined as follows: DANGER Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury or equipment damage. Safety Symbols The following symbols are often marked on SEL products. CAUTION Refer to accompanying documents. ATTENTION Se reporter à la documentation. Earth (ground) Terre Protective earth (ground) Terre de protection Direct current Alternating current Both direct and alternating current Courant continu Courant alternatif Courant continu et alternatif Instruction manual Manuel d instructions 2

3 Safety Marks The following statements apply to this device. General Safety Marks For use in Pollution Degree 3 environment. Pour l'utilisation dans un environnement de Degré de Pollution 3. Per UL compliance, ambient air temperature shall not exceed 40 C (104 F). Terminal Ratings Wire Material Use 75 C (167 F) copper conductors only Tightening Torque Compression Plug: Nm ( in-lb) Compression Plug Mounting Ear Screw: Nm ( in-lb) Stripping Length: 8 mm Holes in the enclosure for mounting and wiring the HMI shall not be greater than 775 mm 2. Conforme à la norme UL, la température ambiante desera de l'air ne doit pas dépasser les 40 C (104 F). Spécifications des bornes Type de filage Utiliser seulement conducteurs en cuivre spécifiés à 75 C (167 F). Couple de serrage Fiche à compression : 0,5 1,0 Nm (4,4 8,8 livres-pouce) Vis à oreille de montage de la fiche à compression : 0,18 0,25 Nm (1,6 2,2 livres-pouce) Longueur de dénudement : 8 mm Les trous dans boîtier pour le montage et le câblage de l IHM ne doivent pas dépasser 775 mm 2. Hazardous Locations Safety Marks WARNING EXPLOSION HAZARD Open circuit before removing cover. WARNING EXPLOSION HAZARD Substitution of components may impair suitability for Class I, Division 2. For ATEX compliance, the ambient temperature range shall be 20 C to +40 C ( 4 F to +104 F). For UL Class I, Division 2 compliance, the ambient temperature range shall be 25 C to +40 C ( 13 F to +104 F). AVERTISSEMENT DANGER D'EXPLOSION Ouvrir le circuit avant de déposer le couvercle. AVERTISSEMENT DANGER D'EXPLOSION La substitution de composants peut détériorer la conformité à Classe I, Division 2. Pour conformer à la norme ATEX, la plage de températures ambiantes sera de 20 C à +40 C ( 4 F à +104 F). Pour conformer à la norme UL Classe I, Division 2, la plage de températures ambiantes sera de 25 C à +40 C ( 13 F à +104 F). Other Safety Marks WARNING Operator safety may be impaired if the device is used in a manner not specified by SEL. WARNING Have only qualified personnel service this equipment. If you are not qualified to service this equipment, you can injure yourself or others, or cause equipment damage. WARNING This device is shipped with default passwords. Default passwords should be changed to private passwords at installation. Failure to change each default password to a private password may allow unauthorized access. SEL shall not be responsible for any damage resulting from unauthorized access. CAUTION Equipment components are sensitive to electrostatic discharge (ESD). Undetectable permanent damage can result if you do not use proper ESD procedures. Ground yourself, your work surface, and this equipment before removing any cover from this equipment. If your facility is not equipped to work with these components, contact SEL about returning this device and related SEL equipment for service. AVERTISSEMENT La sécurité de l opérateur peut être compromise si l appareil est utilisé d une façon non indiquée par SEL. AVERTISSEMENT Seules des personnes qualifiées peuvent travailler sur cet appareil. Si vous n êtes pas qualifiés pour ce travail, vous pourriez vous blesser avec d autres personnes ou endommager l équipement. AVERTISSEMENT Cet appareil est expédié avec des mots de passe par défaut. A l installation, les mots de passe par défaut devront être changés pour des mots de passe confidentiels. Dans le cas contraire, un accès nonautorisé á l équipement peut être possible. SEL décline toute responsabilité pour tout dommage résultant de cet accès nonautorisé. ATTENTION Les composants de cet équipement sont sensibles aux décharges électrostatiques (DES). Des dommages permanents non-décelables peuvent résulter de l absence de précautions contre les DES. Raccordezvous correctement à la terre, ainsi que la surface de travail et l appareil avant d en retirer un panneau. Si vous n êtes pas équipés pour travailler avec ce type de composants, contacter SEL afin de retourner l appareil pour un service en usine. 3

4 Hazardous Locations Approvals In North America, the device is approved for Class I, Division 2, Groups A, B, C, and D, and temperature class T3 in the 25 C to +40 C temperature range. These devices are open-type devices that are to be installed in an enclosure that is accessible only with the use of a tool and suitable for the environment. The compliance labels for the SEL-849 are located on the side of the device. To comply with the requirements of the European ATEX standard for hazardous locations, the SEL-849 shall be installed in an ATEX-certified enclosure with a tool-removable door or cover that provides a degree of protection not less than IP54, in accordance with EN The enclosure should be certified to these requirements or be tested for compliance as part of the complete assembly. The enclosure must be marked WARNING Do not open when an explosive atmosphere is present NE Hopkins Court Pullman, WA USA IND. CONT. EQ. (47BJ) IND. CONT. EQ. FOR USE IN HAZ. LOC. (E470448) HAZARDOUS LOCATIONS CL I, DIV 2; GP A, B, C, D; T3 EU: II 3 G Ex ic ec nc IIC T3 Gc DEMKO 17 ATEX 1832X F Mount Relay on a DIN Rail Relay Mounting The SEL-849 can be mounted on a 35 mm (1.38 in) DIN rail. Install the relay on the DIN rail as shown above. Push the SEL-849 towards the rail until the bottom clip latches and the relay clicks into place. Remove Relay From a DIN Rail To remove the relay, use a small flat-bladed screw driver or other similar tool. Insert the tool into the latching clip and pry it towards the SEL-849 relay. The clip slides away from the DIN rail, releasing it. 4

5 Mount Relay on a Flat Surface SEL-849 Drill Template SEL-849 Relay The screws are #8 (4 mm) and the tightening torque specification is 9.0 in-lbs (1.0 Nm). Refer to Section 2: Installation in the SEL-849 Instruction Manual for more details on installing the SEL-849. Relay Features and Connections Use the panel drilling template for the location of the screw holes. Figure 1 SEL-849 Relay Features and Connections 5

6 Wiring Requirements The torque requirements for the terminal blocks are: Compression Plug Tightening Torque: Minimum: 0.5 Nm (4.4 in-lb) Maximum: 1.0 Nm (8.8 in-lb) Compression Plug Mounting Ear Screw Tightening Torque: Minimum: Nm (1.6 in-lb) Maximum: 0.25 Nm (2.2 in-lb) Ground Terminal Screw Tightening Torque: 1 Nm (8.8 in-lb) The power terminals on the relay (A3 (+/H) and A2 (-/N)) must connect to a 110/240 Vac or 110/250 Vdc, or 24/48 Vdc power source (see Power Supply in the SEL-849 Instruction Manual for complete power input specifications). Wire sizes for connections are dictated by the terminal blocks and expected load currents. You can use the following table as a guide in selecting wire sizes. Connection Type Grounding (Earthing) Current a Potential (Voltage) Contact I/O Other Minimum 18 AWG (0.8 mm 2 ) 16 AWG (1.3 mm 2 ) 18 AWG (0.8 mm 2 ) 18 AWG (0.8 mm 2 ) 18 AWG (0.8 mm 2 ) a. For external 1 A or 5 A CT secondary. Wire Size Maximum 14 AWG (2.1 mm 2 ) 12 AWG (3.3 mm 2 ) 14 AWG (2.1 mm 2 ) 14 AWG (2.1 mm 2 ) 14 AWG (2.1 mm 2 ) Insulation Voltage 300 V min 300 V min 300 V min 300 V min 300 V min The power terminals are isolated from chassis ground. Use 14 AWG (2.1 mm 2 ) to 16 AWG (1.3 mm 2 ) size wire to connect to the power terminals. 6

7 Relay Dimensions Figure 2 SEL-849 Relay Dimension Drawings i8051k Figure 2 shows the dimensions of the relay to cover all the ordering options. Please note that the actual relay may differ based on the options included. The wiring terminal blocks are labeled A through H, as shown in the drawing and on the relay. HMI If you are using the SEL-3421 or SEL-3422 Motor Relay HMI, connect the HMI module to the HMI port of the relay with an SEL-C627M cable or equivalent. The HMI module is powered from the relay. Note that it takes 5 10 seconds for the HMI to come up with the default display. The SEL-3422 must be connected to the SEL-849 for hazardous locations suitability and is part of ATEX certification No. DEMKO 17 ATEX 1832X. The SEL-3421 is not rated for use in hazardous locations applications. Use the HMI to control, meter, or monitor the motor. Refer to Section 8: Human Machine Interface, in the SEL-849 Instruction Manual for more details on HMI functions and operation. NOTE: Make sure the relay, HMI, and SELBOOT firmware revisions are compatible. Refer to Appendix A: Firmware and Manual Versions in the SEL-849 Instruction Manual. 7

8 Relay Communications The SEL-849 includes a built-in web server for configuration and control. Simply connect an Ethernet cable between your computer and the SEL-849 PORT2A or 2B to establish communications. Do not connect your computer to the HMI port. Refer to Section 3: PC Interface, in the SEL-849 Instruction Manual, for more details on the web server connection. Computer Connection Steps 1. Connect your computer and the relay using an Ethernet cable, as shown in the connection diagram. Connect the Ethernet port of your computer to the Ethernet port (PORT 2) of the SEL-849. Use an RJ45 Ethernet cable, such as an SEL-C627M cable, which is a double-shielded, 600 V MCC-rated, category 5e Ethernet cable. SEL-849 HMI PORT2A 2. Turn on both your computer and the relay. (Check the LED status on the SEL-849 for connectivity.) Cat 5e Cable (SEL-C627M or equivalent) 3. Open a web browser and type the default IP address, , in the address bar. 4. Select 2AC: View and Change from the Access Level drop-down menu. 5. Type in the default ACC and 2AC passwords, OTTER and TAIL, respectively. 8

9 6. Click Login. The following settings screen appears on your computer. Use the different menus to navigate, monitor, set, and control the relay. Meter shows corresponding meter reports. Reports contains subcategories for each of the reports stored in the relay. You can view event reports, SER, load profile, etc. Control gives you information about the present targets and the control of remote bits and output contacts. Relay Status displays the Relay Word bits, self tests and SELOGIC counters information. System allows you to export or import settings and download firmware. Instruction Manual can be used to download the manual to the PC. Click Settings to modify the needed settings and click the Submit Changes button to download settings to the relay. 9

10 Typical Application Example and Connections A typical application example is shown below. Numerous other current- and voltage-based protection features can be individually enabled. Additional starter configurations are supported including reversing, two speed, and star-delta. These are described in the instruction manual. Consider a 60 HP three-phase induction motor with a rated voltage of 400 V, rated full load current (FLA) of 80 A and a service factor of The application below uses NEMA 20 for trip class and a full voltage nonreversing starter configuration as shown in Figure 3. This application does not have ac voltage inputs. CBCT CR A B C Current-Limiting Fuses IA IB IC H1 H2 Source Load +/H A3 A2 -/N E1 OUT01 E2 Settings: APP := MOTOR CTRN := xxxx.x STARTRTY := FVNR FACTLOG := Y CURR_IN := NORMAL E3 +DC/H DC/N CR B1 IN01 B2 COM 0102 OUT01 = (STR_CLO OR (OUT01 AND (NOT STOPPED OR 52A))) AND NOT (TRIP OR STOP) (Hidden) OUT02 = 0 (Available for User) OUT03 = (50PAF OR 50GAF) AND TOL1 (Available for User) OUT04 = HALARM or SALARM (Available for User) +DC/H DC/N +DC/H DC/N +DC/H Select STOP START Control Mode REMOTE B3 IN02 B4 IN03 B5 COM 0304 B6 IN04 B7 IN05 B8 COM 0506 B9 IN06 SEL-849 Motor CR Note 1: The CBCT input terminals H1 H2 allow you to connect a core-balance current transformer, which measures the ground fault current directly from the three-phase motor conductors and neutral (when used), passing through it. Note 2: All contact inputs shown are externally wetted. Figure 3 Connection Diagram for Factory-Default I/O Assignments Full-Voltage Nonreversing Starter (STARTRTY := FVNR) With Ungrounded Motor Neutral Typically, a relay out of the box comes with factory-default settings. Alternatively, factory-default settings can be restored by performing DEVICE RESET using the web server as described under Relay Communications. Following are the setting changes required for this application, starting from the factory-default settings. NOTE: Depending on the particular application more setting changes may be necessary, including for the behavior of the SEL-3421 HMI (if used). The settings mentioned below are for the application used in this example. Basic Settings Category Setting Name Setting Range Setting Prompt Setting Value for the Example Application Listed Full Load Amps A FLA1 80 Service Factor SERFACTR 1.12 Trip Class 10_NEMA, 20_NEMA, 30_NEMA, 5_IEC, 10_IEC, 20_IEC, 30_IEC, NONE TRIPCLAS 20_NEMA 10

11 With these settings, the SEL-849 provides the following protection features for this application. Thermal Overload Protection (49): The relay will trip on overload as specified by the Trip Class (20_NEMA) and Service Factor (1.12). An overload warning will be 85 percent of the TCU (thermal capacity used) trip level. The overload reset level is set at 75 percent of the TCU trip level. The relay trips when either stator or rotor TCU reaches 100 percent. Current Unbalance Protection (46): The current unbalance trip pickup is set at 20 percent with a delay of 5 seconds, and the current unbalance warning pickup is set at 10 percent with a delay of 10 seconds. These settings are in per unit of the FLA setting. Phase Reversal Protection (47): The relay will trip approximately 0.5 seconds after a motor start is initiated on detecting an incorrect phase rotation. Output contacts for this application are configured as mentioned on the figure. OUT01 is already set and energizes the contactor coil to start the motor or de-energizes it to stop the motor on a trip condition or STOP command or failure to start condition. OUT04 contact closes on alarm condition or when the user logs into the relay. OUT02 and OUT03 are not used in this application. Input contacts are wired as shown in the figure. IN01 provides the status of the contactor or breaker. IN04 and IN03 are used to provide pushbutton inputs for starting and stopping of the motor, respectively. IN06 is used to select the control mode, i.e., Local or Remote. IN04 and IN03 are pulse inputs that would start/stop a motor. If the optional HMI is connected, START/STOP pushbuttons on the HMI take precedence over IN04 and IN03, respectively. Similarly, the LOCAL/REMOTE pushbutton on the HMI takes precedence over IN06. If the relay is in remote mode, START/STOP can be done from the communications port (serial or Ethernet). Once the settings are completed, enter and save them in the relay using the web server as described in Relay Communications. 11

12 Specifications Compliance Designed and manufactured under an ISO 9001 certified quality management system 47 CFR 15B, Class A Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. * UL has not yet developed requirements for products intended to detect and mitigate an arc flash; consequently, UL has not evaluated the performance of this feature. While UL is developing these requirements, it will place no restriction on the use of this product for arc-flash detection and mitigation. For test results performed by an independent laboratory and other information on the performance and verification of this feature, please contact SEL customer service. UL Listed to U.S. and Canadian safety standards (File E212775, NRGU, NRGU7) CE Mark RCM Mark Hazardous Locations UL Certified for Hazardous Locations to U.S. and Canadian standards (File E470448) EU EN : A11:2013, EN :2015, EN :2010, EN :2012 Note: ATEX and UL Hazardous Locations Certification tests are applicable to rated supply specifications only and do not apply to the absolute operating ranges, continuous thermal, or short circuit duration specifications. General II 3 G Ex ic ec nc IIC T3 Gc DEMKO 17 ATEX 1832X Rogowski Coil-Based AC Current Inputs Phase Rated Range: A Rated Frequency: 50/60 Hz Burden (Per Phase): Not applicable Core-Balance CT Current (IN) Rated Current Range: ma Rated Continuous Thermal Current: 1.0 A 1-Second Thermal Current: 10 A Saturation Current Range: 7 48 ma (actual range will depend on the 50N1P setting) Burden: <0.012 VA at 40 ma AC Voltage Inputs (Line-to-Line) Rated Operating Voltage (Ue): Vac Rated Continuous Voltage: 800 Vac 10-Second Thermal: 1000 Vac Rated Frequency: 50/60 Hz Burden: <0.2 VA Power Supply High-Voltage Supply Rated Supply Voltage: Absolute Operating Range: Power Consumption: 110/240 Vac, 50/60 Hz 110/250 Vdc Vac Vdc <30 VA (ac) <12 W (dc) 20 ms minimum Interruptions: Low-Voltage Supply Rated Supply Voltage: 24/48 Vdc Absolute Operating Range: Vdc Power Consumption: <12 W (dc) Interruptions: 20 ms minimum Output Contacts General Mechanical Durability: 100,000 no-load operations Pickup/Dropout Time: <8 ms (coil energization to contact closure) DC Output Ratings OUT01 (Form C) Rated Operational Voltage: 250 Vdc Rated Voltage Range: Vdc Rated Insulation Voltage: 300 Vdc Make: Vdc per IEEE C37.90 Continuous Carry: 6 70 C 4 85 C Thermal: 50 A for 1 s Contact Protection: 385 Vdc, 9.6 J MOV protection across open contacts Breaking Capacity (10,000 Operations) per IEC :1974: 24 Vdc 0.75 A L/R = 40 ms 48 Vdc 0.50 A L/R = 40 ms 125 Vdc 0.30 A L/R = 40 ms 250 Vdc 0.20 A L/R = 40 ms Cyclic (2.5 Cycles/Second) per IEC :1974: 24 Vdc 0.75 A L/R = 40 ms 48 Vdc 0.50 A L/R = 40 ms 125 Vdc 0.30 A L/R = 40 ms 250 Vdc 0.20 A L/R = 40 ms OUT02, 03, 04 (Form A) Rated Operational Voltage: 30 Vdc Rated Voltage Range: Vdc Rated Insulation Voltage: 300 Vdc Make: 5 30 Vdc Continuous Carry: 4 70 C 3 85 C Thermal: 25 A for 1 s Contact Protection: 385 Vdc, 9.6 J MOV protection across open contacts Breaking Capacity (10,000 Operations) per IEC :1974: 24 Vdc 0.2 A L/R = 40 ms 48 Vdc 0.15 A L/R = 40 ms 125 Vdc 0.1 A L/R = 40 ms 250 Vdc 0.05 A L/R = 40 ms 12

13 Cyclic (2.5 Cycles/Second) per IEC :1974: 24 Vdc 0.2 A L/R = 40 ms 48 Vdc 0.15 A L/R = 40 ms 125 Vdc 0.1 A L/R = 40 ms 250 Vdc 0.05 A L/R = 40 ms AC Output Ratings for OUT01 (Form C), OUT02, OUT03, and OUT04 (Form A) Maximum Operational Voltage (Ue) Rating: 277 Vac Insulation Voltage (Ui) (Excluding EN ) Rating: 300 Vac Utilization Category: AC-15 (control of electromagnetic loads > 72 VA) Contact Rating Designation: B300 (B = 5 A, 300 = rated insulation voltage) Voltage Protection Across Open Contacts: 300 Vac, 9.6 J Rated Operational Current (Ie): Conventional Enclosed Thermal Current (I the ) Rating: Rated Frequency: Vac Vac 5 A 50/60 ±5 Hz Electrical Durability Make VA Rating: 3600 VA, cos = 0.3 Electrical Durability Break VA Rating: 360 VA, cos = 0.3 Optoisolated Control Inputs (Internally Wetted to 24 Vdc) Current Draw at Nominal dc Voltage: 2 ma (at 24 V) Rated Impulse Withstand Voltage (U imp ): 4000 V Pickup Time: <60 ms Dropout Time: <40 ms Optoisolated Control Inputs (Externally Wetted to 24/48 Vdc/Vac or 110/125 Vdc/Vac) Minimum Current Draw: 1.5 ma Rated Impulse Withstand Voltage (U imp ): 4000 V Pickup Time: <60 ms Dropout Time: <40 ms When Used With DC Control Signals: 110/125 Vdc: ON between 95 and Vdc OFF below 70 Vdc 24/48 Vdc: ON between 19.2 and 60 Vdc OFF below 14.4 Vdc When Used With AC Control Signals: 110/125 Vac: ON between 95 and Vac OFF below 66 Vac 24/48 Vac: ON between 19.2 and 60 Vac OFF below 14.4 Vac Analog Output (Optional) Current: 0 20 ma Load at 20 ma: ohms Refresh Rate: 25 ms % Error, Full Scale, at 25 C: ±1% Select From: Analog quantities available in the relay Frequency and Phase Rotation System Frequency: 50, 60 Hz Phase Rotation: ABC, ACB Frequency Tracking: Hz Time-Code Input Simple Network Time Protocol (SNTP) Accuracy Internal Clock: ±5 ms Unsynchronized Clock Drift Relay Powered: 10 minutes per year, typically Communications Ports EIA-232 (as many as 2 Ports) Data Speed: bps EIA-485 Port (as many as 2 Ports) Data Speed: bps Ethernet Port Single/Dual, 10/100BASE-T copper (RJ45 connector) Communications Protocols SEL, Modbus RTU, Modbus TCP, FTP, TCP/IP, Telnet, SNTP, HTTP, HTTPS, IEC (optional) Operating Temperature Rated Range: 40 to +85 C ( 40 to +185 F) Not applicable to UL or ATEX hazardous locations applications Operating Environment Pollution Degree: 3 Overvoltage Category: II Atmospheric Pressure: kpa Relative Humidity: 5 95%, noncondensing Maximum Altitude Without Derating (Consult Factory for Higher Altitude Derating): 2000 m Dimensions 71.1 mm (2.8 in.) x mm (5 in.) x mm (6 in.) Weight 1.0 kg (2.2 lb) Terminal Connections Compression Plug Tightening Torque Minimum: 0.5 Nm (4.4 in-lb) Maximum: 1.0 Nm (8.8 in-lb) Compression Plug Mounting Ear Screw Tightening Torque Minimum: Nm (1.6 in-lb) Maximum: 0.25 Nm (2.2 in-lb) 13

14 Technical Support We appreciate your interest in SEL products and services. If you have questions or comments, please contact us at: Schweitzer Engineering Laboratories, Inc NE Hopkins Court Pullman, WA U.S.A. Telephone: Fax: Internet: selinc.com/support by Schweitzer Engineering Laboratories, Inc. All rights reserved. All brand or product names appearing in this document are the trademark or registered trademark of their respective holders. No SEL trademarks may be used without written permission. SEL products appearing in this document may be covered by US and Foreign patents. Schweitzer Engineering Laboratories, Inc. reserves all rights and benefits afforded under federal and international copyright and patent laws in its products, including without limitation software, firmware, and documentation. The information in this document is provided for informational use only and is subject to change without notice. Schweitzer Engineering Laboratories, Inc. has approved only the English language document NE Hopkins Court Pullman, WA U.S.A. Tel: Fax: selinc.com This product is covered by the standard SEL 10-year warranty. For warranty details, visit selinc.com or contact your customer service representative. Date Code

SEL-3031 Quick-Start Guide

SEL-3031 Quick-Start Guide SEL-3031 Quick-Start Guide Introduction The SEL-3031 is a 900-MHz, license-free, spread-spectrum radio that reliably transports as many as three serial port communications channels in point-to-point or

More information

SEL Radio Accessories Guide

SEL Radio Accessories Guide SEL Radio Accessories Guide Features and Benefits SEL-3031 Serial Radio Transceiver Figure 1 SEL-3031 Wall-Mount Figure 2 SEL-3031 Rack-Mount Uses low-latency data communication for high-speed teleprotection.

More information

SEL Radio Accessories Guide

SEL Radio Accessories Guide SEL Radio Accessories Guide Features and Benefits SEL-3031 Serial Radio Transceiver Figure 1 SEL-3031 Wall-Mount Figure 2 SEL-3031 Rack-Mount Uses low-latency data communication for high-speed teleprotection.

More information

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous GETTING STARTED GUIDE NI 9228 8 AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous This document explains how to connect to the NI 9228. Note Before you begin, complete the software and hardware installation procedures

More information

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous GETTING STARTED GUIDE NI 9239 4 AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous This document explains how to connect to the NI 9239. Note Before you begin, complete the software and hardware installation procedures

More information

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW) Characteristics soft starter-ats22-control 220V-power 230V(55kW)/400...440V(110kW) Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 2383.00 USD Main Range of product

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

SEL-3060 Ethernet Radio Data Sheet

SEL-3060 Ethernet Radio Data Sheet SEL-3060 Ethernet Radio Data Sheet Wireless LAN Extension Major Features and Benefits Two Operating Modes Provide Flexibility. Supports point-to-point radio operation for higher performance and point-to-multipoint

More information

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

Power connections, minimum and maximum wiring capabilities, tightening torque

Power connections, minimum and maximum wiring capabilities, tightening torque Wiring - power terminals Power Observe the cable cross-sectional areas recommended in the standards. The soft starter must be grounded to conform to the regulations concerning leakage currents. If the

More information

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable

More information

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1 Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External

More information

Installation Instructions

Installation Instructions CD-W00-x0-1 Series Wall Mount CO 2 Transmitters Installation Instructions CD-W00-00-1, CD-W00-N0-1 Part No. 24-9601-94, Rev. E Issued August 14, 2014 North American Emissions Compliance United States This

More information

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H018F1 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component

More information

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13 INSTALLATION MANUAL Model: Smart Analyzer Manufacturer: Smart Impulse Power meter with consumption breakdown by use 03/12/13 Table of contents Table of contents... 2 1. Introduction... 3 2. Installation

More information

3-phase meter with direct connection and pulse or Modbus RS485 output

3-phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 3-phase meter with direct connection and CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

GETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling

GETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling GETTING STARTED GUIDE NI 9234 4 AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling This document explains how to connect to the NI 9234. Note Before you begin, complete the software

More information

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External

More information

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

TBX-1329 AC/DC COUPLING TERMINAL BLOCK INSTALLATION GUIDE TBX-1329 AC/DC COUPLING TERMINAL BLOCK Introduction This guide describes how to install and use the TBX-1329 AC/DC coupling terminal block with the SCXI-1120, SCXI-1120D, and SCXI-1121

More information

Single phase meter with direct connection and pulse or Modbus RS485 output

Single phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33(0)5 55 06 87 87 Fax: +33(0)5 55 06 88 88 Single phase meter with direct connection CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

Mid-Power Expansion Unit (MxU) Quick Installation Sheet

Mid-Power Expansion Unit (MxU) Quick Installation Sheet Mid-Power Expansion Unit (MxU) Quick Installation Sheet CMA-597-AEN GENERAL INFORMATION 1. THE MxU supports the 2.5 GHz TDD band and is installed in conjunction with the mid-power remote unit (MRU) (ordered

More information

Custom "Compact" range with display CD20 Custom Part number

Custom Compact range with display CD20 Custom Part number Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable

More information

MU110-16R(K) Digital output module 16 channel. User guide

MU110-16R(K) Digital output module 16 channel. User guide MU110-16R(K) Digital output module 16 channel User guide MU110-16R(K)_2016.12_0220_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany

More information

MU110-8R(K) Digital output module 8 channel. User guide

MU110-8R(K) Digital output module 8 channel. User guide MU110-8R(K) Digital output module 8 channel User guide MU110-8R(K)_2019.01_0296_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany

More information

02/11/2015

02/11/2015 Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine

More information

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Product availability : Stock - Normally stocked in distribution facility Price* : 191.76 USD Main Range of

More information

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I Memory 256 MB Alarm management Residual current measurement Homepage Ethernet-Modbus gateway BACnet (optional) UMG 96 RM-E Power analyser with Ethernet and RCM Communication Modbus (RTU, TCP, Gateway)

More information

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER QUICK START GUIDE ICD201A INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - What s Included ICD201A Industrial Opto-Isolated RS-232 to RS-422/485

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements GETTING STARTED GUIDE NI 9206 16 AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements This document explains how to connect to the NI 9206. Note Before

More information

BLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany

BLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany 2354235 11/2008 Soft start - soft stop unit SH31 User manual 09/2010 BLEMO Frequenzumrichter Siemensstraße 4 D-63110 Rodgau Dudenhofen Germany Tel.: ++49 / 6106 / 82 95-0 Fax: ++49 / 6106 / 82 95-20 Internet:

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

02/11/2015

02/11/2015 "Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue

More information

Agilent G1888 Network Headspace Sampler

Agilent G1888 Network Headspace Sampler Agilent G1888 Network Headspace Sampler Safety and Regulatory Information Agilent Technologies Notices Agilent Technologies, Inc. 2004 No part of this manual may be reproduced in any form or by any means

More information

GETTING STARTED GUIDE NI khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module

GETTING STARTED GUIDE NI khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module GETTING STARTED GUIDE NI 9770 30 khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module This document explains how to connect to the NI 9770. Note Before you begin, complete the software and hardware installation

More information

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Modular versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW Characteristics soft starter for asynchronous motor - ATS48-65 A - 208..690 V - 15..55 KW Main Range of product Altistart 48 Product or component type Product destination Product specific application Device

More information

SLC 500 RTD/Resistance Input Module

SLC 500 RTD/Resistance Input Module Installation Instructions SLC 500 RTD/Resistance Input Module (Catalog Number 1746-NR8) Inside page Important User Information... 2 For More Information... 3 Hazardous Location Considerations... 4 Environnements

More information

A53106 SERIES DC-TO-DC CONVERTER

A53106 SERIES DC-TO-DC CONVERTER INSTALLATION & MAINTENANCE A53106 SERIES DC-TO-DC CONVERTER AUGUST 2011, REVISED AUGUST 2014 DOCUMENT NO. COM-00-04-20 VERSION C.1 Siemens Industry, Inc., Rail Automation 9568 Archibald Ave., Suite 100,

More information

User and Safety Manual ProLine P224xx P1

User and Safety Manual ProLine P224xx P1 The Art of Measuring. User and Safety Manual ProLine P224xx P1 English 17 Loop-Powered Isolators/Splitters www.knick-international.com Contents 17 Safety Information 18 Short Description 19 Intended Use

More information

Introduction DIN rail mounted electricity meters

Introduction DIN rail mounted electricity meters Introduction DIN rail mounted electricity meters Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. DIN rail

More information

SEL-2664 Field Ground Module Data Sheet

SEL-2664 Field Ground Module Data Sheet SEL-2664 Field Ground Module Protect Against Major Damage by Adding Field Ground Protection to the SEL-300G, SEL-700G, and SEL-2664S Relays With the SEL-2664 High Reliability, Low Price Ten-Year, Worldwide

More information

em4 em4 alert em4 alert 2G

em4 em4 alert em4 alert 2G em4 em4 alert em4 alert 2G Connect your equipment to the GPRS 2G network and get alerted by SMS or email Control your application by SMS Receive data reports by SMS or datalogs by email or FTP in.csv (Excel)

More information

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual TE200S Solid State Relays Two-phase control of three-phase loads User manual Copyright Eurotherm Automation 1998 All rights reserved. All reproduction or transmission in any form or using any procedure

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

02/11/2015

02/11/2015 Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions

More information

SECTION AUTOMATIC TRANSFER SWITCH

SECTION AUTOMATIC TRANSFER SWITCH SECTION 26 36 23 PART 1 - GENERAL 1.1 THE REQUIREMENT A. Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, withstand and close-on ratings as shown on the plans.

More information

TVB-2 INSTRUCTION SHEET. Test Verification Box

TVB-2 INSTRUCTION SHEET. Test Verification Box TVB- INSTRUCTION SHEET Test Verification Box V.07.08 DECLARATION OF CONFORMITY Manufacturer: Address: Product Name: Model Number: Associated Research, Inc. 3860 W. Laurel Dr. Lake Forest, IL 60045, USA

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

em4 local - Robust Specific characteristics Part number

em4 local - Robust Specific characteristics Part number em4 em4 local em4 local Very compact and easy to program nanoplc Save time in designing your application using the most intuitive graphical function block language of the market Measure accurately your

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

QUINT-PS AC/24DC/40

QUINT-PS AC/24DC/40 Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high

More information

Three-phase monitoring relays CM-PFE and CM-PFE.2

Three-phase monitoring relays CM-PFE and CM-PFE.2 Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

ControlNet Modular Repeater Medium Distance Fiber Module

ControlNet Modular Repeater Medium Distance Fiber Module Installation Instructions ControlNet Modular Repeater Medium Distance Fiber Module Cat. Nos. 9904-RPFM Use this document as a guide when you install a ControlNet repeater fiber module for medium distances.

More information

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent

More information

Universal-Transducer Multi-E11-MU

Universal-Transducer Multi-E11-MU Universal-Transducer Multi-E11-MU Safety Informations Observe instructions! The device described in these instructions shall only be installed by a qualified electrician according to both EN 50110-1/-2

More information

Telex. User Instructions. Model SPS2000A Power Supply Audiocom Intercom Systems SPS2000A. Volume RESET

Telex. User Instructions. Model SPS2000A Power Supply Audiocom Intercom Systems SPS2000A. Volume RESET R Telex User Instructions SPS000A RESET Volume Model SPS000A Power Supply Audiocom Intercom Systems FCC Statement This equipment uses, and can radiate radio frequency energy that may cause interference

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device

More information

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

/2008. Altistart 22. Soft start - soft stop unit. User manual 09/2009 BBV

/2008. Altistart 22. Soft start - soft stop unit. User manual 09/2009 BBV 2354235 11/2008 Altistart 22 Soft start - soft stop unit User manual 09/2009 BBV51330 www.schneider-electric.com Content Important Information 4 Before you begin 5 Documentation structure 6 Steps for

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Protection components

Protection components Multifunction protection relays LT-P Environment Conforming to standards IEC 947-4-1, IEC 34-11, IEC 755, VDE 010, VDE 00. &Ãmarking Meets the essential requirements of the Low Voltage equipment (LV) &

More information

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017 Ref: ART-B22-D70, ART-B22-D125, ART-B22-D175, ART-B22-D300 Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and

More information

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/ EU and the Electromagnetic Compatibility (EMC)

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

VP4102 Reader 434/922 MHz

VP4102 Reader 434/922 MHz white brown orange white orange blue white blue black red VP4102 Reader 434/922 MHz This sheet is intended as quick start. See service manual for more detailed instructions. The VP4102 reader is a component

More information

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71 Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71 DPC71 PPC71 TRMS 3-phase over and under voltage, phase sequence, phase loss, asymmetry and tolerance monitoring relay Detect

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

Protection components

Protection components General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2 PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00

More information

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum DEVICE SPECIFICATIONS NI 6624 This document lists the specifications for the NI PCI/PXI-6624 device. These specifications are typical at 25 C unless otherwise noted. Refer to the NI 6624 User Manual for

More information

C-Bus 8 Channel Low Voltage Relay

C-Bus 8 Channel Low Voltage Relay SLC5108RELVP Instruction Bulletin Retain for future use. 63249-420-325A1 Instruction Bulletin 07/2009 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to

More information

Three-phase monitoring relay CM-PBE

Three-phase monitoring relay CM-PBE Data sheet Three-phase monitoring relay CM-PBE The three-phase monitoring relay CM-PBE monitors the phase parameter phase failure in three-phase mains. 2CDC 251 007 S0012 Characteristics Monitoring of

More information

Zelio Control Measurement Relays

Zelio Control Measurement Relays Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and

More information

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2 OBA -switch Type 017._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EC Low Voltage Directive 2014/35/ EC and the EMC Directive

More information

ESwitch. User Guide. Power Contactor

ESwitch. User Guide. Power Contactor ESwitch User Guide Power Contactor HA032323ENG issue 4 July 2017 2 ESwitch User Guide Power solid state contactors ESwitch Series For the control of heating elements up to 25kW User Guide Before installation,

More information