RADIO TEST REPORT SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD. Prepared By : SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD

Size: px
Start display at page:

Download "RADIO TEST REPORT SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD. Prepared By : SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD"

Transcription

1 SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD RADIO TEST REPORT Prepared For : SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD 3rd and 4th Floor,6th Building No.888,Shuangbai Road, Minhang District,Shanghai,China Product Name: Model : LED REMOTE CONTROL SYSTEM CT402-RF,CT302-RF Prepared By : Shenzhen BST Technology Co., Ltd. Test Date: Apr , F,Weames Technology Building,No. 10 Kefa Road, Science Park,Nanshan District,Shenzhen,Guangdong,China Date of Report : Apr. 29, 2011 Report No.: BST Y-1ER-7 Page 1 of 22

2 TABLE OF CONTENTS TEST REPORT DECLARATION TEST RESULTS SUMMARY GENERAL INFORMATION Report information Measurement Uncertainty PRODUCT DESCRIPTION EUT Description Block Diagram of EUT Configuration Operating Condition of EUT Test Conditions Modifications Abbreviations TEST EQUIPMENT USED Test Equipment Used to Measure Radiated Disturbance TECHNICAL TEST Summary of Test Results Test Report TRANSMITTER REQUIREMENTS Frequency Error or Frequency Drift CARRIER POWER(CONDUCTED) EFFECTIVE RADIATED POWER SPREAD SPECTRUM MODULATION TRANSIENT POWER ADJACENT CHANNEL POWER MODULATION BANDWIDTH FOR WIDE BAND EQUIPMENT SPURIOUS EMISSIONS FREQUENCY STABILITY UNDER LOW VOLTAGE CONDITIONS DUTY CYCLE PRINCIPLE FOR LISTEN BEFORE TALK (LBT) RECEIVER REQUIREMENTS MAXIMUM USABLE SENSITIVITY (CONDUCTED) RECEIVER LBT THRESHOLD AND TRANSMITTER MAX ON-TIME Page 2 of 22

3 20. ADJACENT CHANNEL SELECTIVEITY BLOCKING OR DESENSITIZATION INTERMODULATION RESPONSE REJECTION SPURIOUS RESPONSE REJECTION SPURIOUS RADIATIONS APPENDIX EUT PHOTO & TEST PHOTO Page 3 of 22

4 TEST REPORT DECLARATION Applicant : SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD Address : 3rd and 4th Floor,6th Building No.888,Shuangbai Road, Minhang District,Shanghai,China Manufacturer : SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD Address : 3rd and 4th Floor,6th Building No.888,Shuangbai Road, Minhang District,Shanghai,China EUT : Description LED REMOTE CONTROL SYSTEM Model Number : CT402-RF,CT302-RF Test Standards: ETSI EN v ( ) ETSI EN v ( ) The EUT described above is tested by BST Technology Co.,Ltd. EMC Laboratory to determine the maximum emissions from the EUT and ensure the EUT to be compliance with the immunity requirements of the EUT. BST Technology Co.,Ltd. EMC Laboratory is assumed full responsibility for the accuracy of the test results. Also, this report shows that the EUT technically complies with the 99/5/EEC directive and its amendment requirements. The test report is valid for above tested sample only and shall not be reproduced in part without written approval of the laboratory. Page 4 of 22

5 1. TEST RESULTS SUMMARY Table 1 Test Results Summary Test Items Refer to Page 9 Test Results PASS 2. GENERAL INFORMATION 2.1. Report information This report is not a certificate of quality; it only applies to the sample of the specific product/equipment given at the time of its testing. The results are not used to indicate or imply that they are application to the similar items. In addition, such results must not be used to indicate or imply that BST approves recommends or endorses the manufacture, supplier or use of such product/equipment, or that BST in any way guarantees the later performance of the product/equipment The sample/s mentioned in this report is/are supplied by Applicant, BST therefore assumes no responsibility for the accuracy of information on the brand name, model number, origin of manufacture or any information supplied Additional copies of the report are available to the Applicant at an additional fee. No third part can obtain a copy of this report through BST, unless the applicant has authorized BST in writing to do so Measurement Uncertainty Available upon request. Page 5 of 22

6 3. PRODUCT DESCRIPTION 3.1. EUT Description Description : LED REMOTE CONTROL SYSTEM Applicant Model Number : CT402-RF Operation Frequency : SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD : 433MHz Page 6 of 22

7 3.2. Block Diagram of EUT Configuration battery Receiver Remote Controller Figure 1 EUT SETUP 3.3. Operating Condition of EUT Test mode 1: TX Test mode 2: RX 3.4. Test Conditions Temperature: -20~55 Relative Humidity: 50~70 % 3.5. Modifications No modification was made Abbreviations AC AMN DC EM EMC EUT IF RF rms EMI EMS Alternating Current Artificial Mains Network Direct Current ElectroMagnetic ElectroMagnetic Compatibility Equipment Under Test Intermediate Frequency Radio Frequency root mean square Electromagnetic Interference Electromagnetic Susceptibility Page 7 of 22

8 4. TEST EQUIPMENT USED 4.1. Test Equipment Used to Measure Radiated Disturbance Table 3 For Spurious Emission Test NO. Equipment Manufacturer Model No. Last Cal. Cal. Interval SB3436 EMI Test Rohde & ESI26 Jan 30, Year Receiver Schwarz SB3440 Bilog Antenna Chase CBL6112B Jan 30, Year SB3438 Signal Rohde & SMR20 Jan 30, Year Generator Schwarz SB3174 Antenna Schwarzbeck VUBA911 7 Jan 30, Year SB3434 Horn Antenna Rohde & HF906 Jan 30, Year Schwarz SB3435 Horn Antenna Rohde & HF906 Jan 30, Year Schwarz SB3450/0 1 3m Semi-anechoic chamber Albatross Projects 9X6X6 Mar 23, Year Table 4 RF Test NO. Equipment Manufacturer Model No. Last Cal. Cal. Interval SB3436 EMI Test Rohde & ESI26 Jan 30, Year Receiver Schwarz SB3440 Bilog Antenna Chase CBL6112B Jan 30, Year SB3438 Signal Rohde & SMR20 Jan 30, Year Generator Schwarz SB3997 EMI Receiver Rohde & ESPI3 Jan 30,2011 1Year Schwarz Page 8 of 22

9 5. TECHNICAL TEST 5.1. Summary of Test Results No deviations from the technical specification(s) were ascertained in the course of the tests Performed (only Passed if all single measurements are passed passed 5.2. Test Report Test Report Reference List of Measurements Parameter to be Measured Clause Transmitter Parameters Transmitter Requirements Clause Frequency Error or Frequency Drift Clause Carrier Power (conducted) Clause Effective Radiated Power Clause Transient power Clause Adjacent Channel Power Clause Modulation Band Width for Wide Band Equipment Clause Spurious Emissions Clause Frequency Stability under Low-voltage Conditions Clause Duty Cycle Clause LBT Clause Types of spread spectrum modulation Clause Receiver Parameters Receiver Requirements Clause 4.2 Types of spread spectrum modulation Clause Receiver LBT threshold and transmitter max Clause on-time Adjacent channel selectivity Clause Blocking or Desensitization Clause Intermodulation response rejection Clause Spurious response rejection Clause Spurious radiations Clause Note : the clause numbers are referenced to ETSI EN v ( ) Page 9 of 22

10 6. TRANSMITTER REQUIREMENTS Note: The Tx is a modulation by analogue signal no voice application with an integral or dedicated antenna Frequency Error or Frequency Drift The method of measurement described under EN EUT LED REMOTE CONTROL Model CT402-RF SYSTEM Mode TX Input Power 4.5V Sub clause EN Clause8.1.4 Test Equipment Refer to Section 4 TEST RESULTS:Uncertainty ±10Hz Test Conditions Frequency Measured(MHz) T normal (25 ) 4.5V norm T upper (+55 ) 4.5V norm After Tx on for 30 minutes 4.05V extreme T lower (-10 ) 4.5V norm After Tx on for 1 minute 4.05V extreme Limit Frequency Error ±12.0kHz Note: 1. The minimum voltage is set by the manufacturer where the Tx can keep working normally. 2. The Tx is a modulation by analogue signal no voice application with an integral or dedicated antenna. Limits: EN ,subclause The frequency error or drift shall not exceed the values given in table 7 under normal or extreme conditions. Table 7 Page 10 of 22

11 7. CARRIER POWER(CONDUCTED) The method of measurement described under EN ,subclause8.2.2 Note: Not applicable, This requirement applies to transmitters which may be used without an integral or dedicated antenna 8. EFFECTIVE RADIATED POWER The method of measurement described under EN ,subclause8.3.2 On a test site, selected from annex A, the equipment shall be placed at the specified height on a support, as specified in annex A, and in the position closest to normal use as declared by the manufacturer. The test antenna shall be oriented initially for vertical polarization and shall be chosen to correspond to the frequency of the transmitter. The output of the test antenna shall be connected to the measuring receiver. The transmitter shall be switched on, if possible, without modulation and the measuring receiver shall be tuned to the frequency of the transmitter under test. In case of pulse modulation equipment where it is not possible to make the measurement in the absence of modulation, the measurement shall be carried out by the use of a measuring receiver with bandwidth as stated in subclause 6.6 and peak detector set in accordance with the specification of CISPR 16 [8] section one for the bands C and D. The test antenna shall be raised and lowered through the specified range of height until a maximum signal level is detected by the measuring receiver. The transmitter shall then be rotated through 360 in the horizontal plane, until the maximum signal level is detected by the measuring receiver. The test antenna shall be raised and lowered again through the specified range of height until a maximum signal level is detected by the measuring receiver. The maximum signal level detected by the measuring receiver shall be noted. The transmitter shall be replaced by a substitution antenna as defined in annex A, subclause A.1.5. The substitution antenna shall be orientated for vertical polarization and the length of the substitution antenna shall be adjusted to correspond to the frequency of the transmitter. The substitution antenna shall be connected to a calibrated signal generator. If necessary, the input attenuator setting of the measuring receiver shall be adjusted in order to Page 11 of 22

12 increase the sensitivity of the measuring receiver. The test antenna shall be raised and lowered through the specified range of height to ensure that the maximum signal is received. The input signal to the substitution antenna shall be adjusted to the level that produces a level detected by the measuring receiver, that is equal to the level noted while the transmitter radiated power was measured, corrected for the change of input attenuator setting of the measuring receiver. The input level to the substitution antenna shall be recorded as power level, corrected for any change of input attenuator setting of the measuring receiver. The measurement shall be repeated with the test antenna and the substitution antenna orientated for horizontal polarization. The measure of the effective radiated power is the larger of the two levels recorded at the input to the substitution antenna, corrected for gain of the substitution antenna if necessary. EUT LED REMOTE CONTROL Model CT402-RF SYSTEM Mode TX Input Power 4.5V Sub clause EN Clause8.3.2 Test Equipment Refer to Section 4 TEST RESULTS:Uncertainly ±3dB Frequency Measuring Bandwidth Emission Level Limit in Table kHz -1.93dBm 10dBm(i.e.=10mW) Limits: EN ,subclause The effective radiated power shall not exceed the power class value given in table 9 Table 9 Power class Power level mw 5a 0,025 7a Page 12 of 22

13 9. SPREAD SPECTRUM MODULATION The method of measurement described under EN Note: Not applicable, This equipment is not spread spectrum product. Please refer to clause 8.4 of EN TRANSIENT POWER The method of measurement described under EN The transmitter under test shall be connected via the power attenuator to the "transient power measuring device" as described in clause 8.5.3, so that the level at its input is suitable, e.g. between 0 dbm and -10 dbm when the transmitter power is the steady state power. The modulation test signal (see clause or as appropriate) shall be applied at the transmitter. For constant envelope modulation schemes it is not required to apply modulation. The modulation used, if any, shall be recorded in the test report. The measurement procedure shall be as clause 8.5 of EN Limits: EN ,subclause The transient power in the alternate channel shall not exceed a value of 40 db below the power of the transmitter without the need to be below 2 μw (-27,0 dbm). For measurements at 4 and 10 times the channel spacing the transient power shall not exceed 50 db below power of the transmitter without the need to be below 250 nw (-36 dbm). If the limit is exceeded the measurement in clause shall be repeated with the attenuator value reduced by 6 db to determine if transient effect is causing errors. Note :Not applicable for the product. Page 13 of 22

14 11. ADJACENT CHANNEL POWER The method of measurement described under EN ,subclause The adjacent channel power shall be measured with a power measuring receiver which conforms with the requirements given in annex B When using the test fixture (see subclause6.3) for this measurement, it is important to ensure that direct radiation from the transmitter to the power measuring receiver does not affect the result or the loss introduced by the testfixture. The following procedure shall be used: a) the transmitter under test shall be connected via the test load to a power measuring receiver calibrated to measure rms power level. The level at the receiver input shall be within its allowed limit. The transmitter shall be operated at the maximum operational carrier power level under normal conditions; b) the tuning of the power measuring receiver shall be adjusted away from the carrier so that its -6dB response nearest to the transmitter carrier frequency is located at a displacement from the nominal frequency of the carrier asgivenintable11. Table 11 Channel separation (khz) Displacement (khz) 10 5,75 12,5 8, The same result maybe obtained by tuning the power measuring receiver (point 0 in figure B.1 of the power measuring filter shape) to the nominal frequency of the adjacent channel,if it has been suitably calibrated. c) the transmitter shall be modulated as follows: -equipment for analogue speech and angle modulation shall be modulated with test signal A-M2 (see subclause6.1.1)at a level 20dB above the level of the normal test signal, or 10dB incase of a transmitter with an integrated microphone: (see sub clause 6.1.1)at a level which is 20dB higher than the level that is required to produce a modulation depth of 60%, or 10dB incase of a transmitter with an integrated microphone; -equipment using data streams shall be modulated with the test modulationd-m2(see subclause6.1.2)at the agreed deviation or modulation depth; -equipment for messages shall be modulated with the test modulationd-m3(see subclause6.1.2)repeated continuously at the agreed deviation or modulation depth. d) The absolute value of the adjacent channel power shall be recorded; e) Steps b)to d) shall be repeated with the power measuring receiver tuned to the other side of the carrier; f) The measurement shall be made under normal conditions and, if applicable, under extreme conditions (see clause8) Page 14 of 22

15 Limits:EN ,subclause The adjacent channel power shall not exceed the maximum value given in table 12. Table 12 Note :Not applicable for the product. Page 15 of 22

16 12. MODULATION BANDWIDTH FOR WIDE BAND EQUIPMENT The method of measurement described under EN ,subclause Note :Not applicable, Please refer to clause 4.1.7& of EN Page 16 of 22

17 13. SPURIOUS EMISSIONS The method of measurement described under EN EUT LED REMOTE CONTROL Model CT402-RF SYSTEM Mode TX Input Power 4.5V Sub clause EN Clause8.7.4 Test Equipment Refer to Section 4 Frequency Measuring TEST RESULTS:Uncertainly ±6dB Spurious Emission Level (dbm) Limit in Table 13 (dbm) (MHz) Bandwidth Operation Standby Operation Standby kHz NF MHz NF MHz NF Note :NF=No Significant Peak was Found. Note: Scan form 25MHz to 4GHz,find the maximum radiation frequency to measure. Limits:EN ,subclause The power of any spurious emission,conducted or radiated, shall not exceed the following values given in table 13. Table FREQUENCY STABILITY UNDER LOW VOLTAGE CONDITIONS The method of measurement described under EN ,subclause The carrier frequency shall be measured, where possible in the absence of modulation, with the transmitter connected to an artificial antenna. A transmitter without a 50 Ω output connector may be placed in a test fixture (see subclause 6.3) connected to an artificial antenna. The measurement shall be made under normal temperature and humidity conditions (see subclause 5.3.1), the voltage from the test power source shall be reduced below the lower extreme test voltage limit towards zero. Whilst the voltage is reduced the carrier frequency shall be monitored. Page 17 of 22

18 EUT LED REMOTE CONTROL Model CT402-RF SYSTEM Mode TX Input Power 4.5V Sub clause EN Clause8.8.2 Test Equipment Refer to Section 4 Voltage (Vdc) <4.5 Frequency (MHz) TEST RESULTS:Uncertainly ±6dB Radiated Level Limit in clause of EN (dbm) The equipment shall either: a) remain on channel, for channelized equipment within the limits stated in subclause 8.1.4,or within the assigned operating frequency band, for non-channelized equipment,whilst the radiated or conducted power is greater than the spurious emission limit;or b) the equipment ceases to function below the manufacturers declared operating voltage. The equipment ceases to function below the applications declared operating voltage. 15. DUTY CYCLE The method of measurement described under EN The Duty cycle of EUT is class PRINCIPLE FOR LISTEN BEFORE TALK (LBT) The method of measurement described under EN Note :Not applicable,the equipment does not use LBT. Page 18 of 22

19 17. RECEIVER REQUIREMENTS For Receiver Receiver Classification,Table 2 of EN Table 2 Receiver class Relevant receiver clauses Risk assessment of receiver performance 1 9.1,9.2,9.3and 9.4 Highly reliable SRD communication media;e.g. serving human life inherent systems (may result in a physical risk to a person) 2 9.3and 9.4 Medium reliable SRD communication media e.g. causing inconvenience to persons, which cannot simply be overcome by other means Standard reliable SRd communication media e.g. inconvenience to persons, which can simply be overcome by other means(e.g. manual) NOTE: With reference to the present document manufacturers are recommended to declare classification of their devices in accordance with table 2 and EN ,subclause 4.2,as relevant. In particular where an SRD which may have an inherent safety of human life implication, Manufacturers and users should pay particular attention to the potential for interference from other systems operating in the same or adjacent bands. Note: The EUT (Rx part )belong to Class MAXIMUM USABLE SENSITIVITY (CONDUCTED) For Receiver The method of measurement described under EN ,subclause Note: Not applicable, This requirement applies to with listen before talk (LBT) facility. 19. RECEIVER LBT THRESHOLD AND TRANSMITTER MAX ON-TIME For Receiver The method of measurement described under EN ,subclause Note: Not applicable, This requirement applies to with listen before talk (LBT) facility. Page 19 of 22

20 20. ADJACENT CHANNEL SELECTIVEITY For Receiver The method of measurement described under EN ,subclause Note: Not applicable, This requirement applies to class 1 receivers, as defined in EN ,subclause BLOCKING OR DESENSITIZATION For Receiver The method of measurement described under EN ,subclause Note: Not applicable,this requirement applies to class 1 and class 2 receivers, as defined in EN ,subclause INTERMODULATION RESPONSE REJECTION For Receiver The method of measurement described under EN ,subclause Note: Not applicable,this requirement applies to class 1 receivers, as defined in EN ,subclause SPURIOUS RESPONSE REJECTION For Receiver The method of measurement described under EN ,subclause Note: Not applicable,this requirement applies to class 1 receivers, as defined in EN ,subclause4.1.1 Page 20 of 22

21 24. SPURIOUS RADIATIONS For Receiver The method of measurement described under EN ,subclause EUT LED REMOTE CONTROL Model CT402-RF SYSTEM Mode RX Input Power 12V Sub clause EN Clause9.7.5 Test Equipment Refer to Section 4 Frequency (MHz) Measuring Bandwidth kHz MHz MHz TEST RESULTS:Uncertainly ±6dB Spurious Emission Limit in Table 13 (dbm) Level (dbm) (1) 2nW (-57dBm) below 1000MHz (2)20nW (-47dBm) above 1000MHz Note:NF=No significant Peak was Found Note: Scan form 25MHz to 4GHz,find the maximum radiation frequency to measure. Page 21 of 22

22 APPENDIX EUT PHOTO & TEST PHOTO Refer to report BST Y-1ER-1 Page 22 of 22

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC. Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial

More information

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province. DONGGUAN FIT-WATCH CO., LTD. EMC REPORT Prepared For : DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province Product Name : Trade Name : Model

More information

RADIO test report. According to the standards:

RADIO test report. According to the standards: RADIO test report According to the standards: EN 300 220-1 v2.4.1 (2012-10) EN 300 220-2 v2.4.1 (2012-10) EN 300 220-1 V 3.1.1 (2017-02) EN 300 220-2 V 3.1.1 (2017-02) Equipment under test: Electronic

More information

ETSI EN V1.3.1 ( )

ETSI EN V1.3.1 ( ) EN 300 224-1 V1.3.1 (2001-01) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); On-site paging service; Part 1: Technical and functional characteristics,

More information

FINGERTEC WORLDWIDE SDN BHD FCC REPORT FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, PUCHONG, SELANGOR, MALAYSIA

FINGERTEC WORLDWIDE SDN BHD FCC REPORT FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, PUCHONG, SELANGOR, MALAYSIA FINGERTEC WORLDWIDE SDN BHD FCC REPORT Prepared For : FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, 47100 PUCHONG, SELANGOR, MALAYSIA Product Name: Trade Name: Fingerprint T&A

More information

EN RADIO Test REPORT

EN RADIO Test REPORT Page 1 of 53 EN 300 086 RADIO Test REPORT On Behalf of Zhengzhou Eshow Import and Export Trade Co., Ltd. Two way radio Model No.: RT-5RV Prepared for : Zhengzhou Eshow Import and Export Trade Co., Ltd.

More information

EN / EN RADIO TEST REPORT. Shanghai Anviz Technology Co.Ltd Fingerprint & RFID Time Attendance Model No.: A300

EN / EN RADIO TEST REPORT. Shanghai Anviz Technology Co.Ltd Fingerprint & RFID Time Attendance Model No.: A300 Page 1 of 28 Report No.: T1861387 02 EN 300 330-1/ EN 300 330-2 RADIO TEST REPORT On Behalf of Shanghai Anviz Technology Co.Ltd Fingerprint & RFID Time Attendance Model No.: A300 Prepared for : Shanghai

More information

REMARKS The customer has ordered two measurements mentioned above according to the standard EN

REMARKS The customer has ordered two measurements mentioned above according to the standard EN Type: Alignment range: Switching range: SATELLINE-3ASm/250/LC 380,000-470,000 MHz One channel Equipment 1 and 2 Equipment Equipment Measurement Serial no. 033322036 and 033322037 Serial no. Serial no.

More information

STC Test Report. Date : Page 1 of 13 No. : HM161169

STC Test Report. Date : Page 1 of 13 No. : HM161169 Date : 2009-05-11 Page 1 of 13 Applicant (ATS001): Atech Scientific Measurement Limited. Room A-C, 18 Floor, Luk Hop Ind. Bldg, 8 Luk Hop Street, Kowloon Manufacturer: Atech Scientific Measurement Limited.

More information

RF Test Report. Report No.: AGC EE13. CLIENT : Zhengzhou Eshow Import and Export Trade Co.,Ltd.

RF Test Report. Report No.: AGC EE13. CLIENT : Zhengzhou Eshow Import and Export Trade Co.,Ltd. Page 1 of 80 RF Test Report Report No.: AGC08074160901EE13 PRODUCT DESIGNATION : Two way radio BRAND NAME : Retevis MODEL NAME : RT1 CLIENT : Zhengzhou Eshow Import and Export Trade Co.,Ltd. DATE OF ISSUE

More information

RADIO TEST REPORT ETSI EN V2.4.1( ) For

RADIO TEST REPORT ETSI EN V2.4.1( ) For RADIO TEST REPORT ETSI EN 300 220-2 V2.4.1(2012-05) For Applicant : CNEX AIE SL Address : C/ Mendez Nuñez,49 08302 Mataró - Barcelona - Spain Product Name : Massager 33431, 107530, 108216, 108339, 108735,

More information

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( ) EN 302 208-1 V1.1.1 (2004-09) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Radio Frequency Identification Equipment operating in the band

More information

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm) Page 41 of 103 9.6. Test Result The test was performed with 802.11b Channel Frequency (MHz) power ANT 1(dBm) power ANT 2 (dbm) power ANT 1(mW) power ANT 2 (mw) Limits dbm / W Low 2412 7.20 7.37 5.248 5.458

More information

ETSI EN V1.1.3 ( )

ETSI EN V1.1.3 ( ) EN 300 433-1 V1.1.3 (2000-12) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Double Side Band (DSB) and/or Single Side

More information

Electrical FOR:

Electrical FOR: 839.01 Electrical Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: mail@hermonlabs.com TEST REPORT ACCORDING TO: EN 300 113-2

More information

King Pigeon Communication Co., Limited

King Pigeon Communication Co., Limited APPLICATION FOR ELECTROMAGNETIC COMPATIBILITY DIRECTIVE On Behalf of King Pigeon Communication Co., Limited Remote Controller RTU Model No.: S130, S140, S150, S180, S25x, S26x, S27x, RTU501x, RTU502x,

More information

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU

More information

RF Test Report. Report No.: AGC EE13 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.

RF Test Report. Report No.: AGC EE13 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO. Page 1 of 52 RF Test Report PRODUCT DESIGNATION BRAND NAME TEST MODEL CLIENT : Dual Band Mobile Radio : VGC : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.,LTD DATE OF

More information

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd.

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd. Page 1 of 43 FCC Test Report Report No.: AGC03588150607FE02 FCC ID : 2AE6GUHF 6000HHM APPLICATION PURPOSE : ORIGINAL EQUIPMENT PRODUCT DESIGNATION : Wireless Microphone BRAND NAME : Gemini MODEL NAME :

More information

Draft ETSI EN V1.1.1 ( )

Draft ETSI EN V1.1.1 ( ) Draft EN 302 291-1 V1.1.1 (2004-07) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Close Range Inductive Data Communication

More information

ETSI EN RADIO TEST REPORT

ETSI EN RADIO TEST REPORT Report No:DDT-RE140701 Issued Date: Oct.23,2014 ETSI EN300 220 RADIO TEST REPORT FOR Applicant : HOPE MICROELECTRONICS CO.,LTD 2/F,Building3,pingshan Private Enterprise science and Address : Technology

More information

DraftETSI EN V1.1.1 ( )

DraftETSI EN V1.1.1 ( ) Draft EN 301 783-1 V1.1.1 (2000-03) European Standard (Telecommunications series) Electromagnetic compatibility and Radio Spectrum Matters (ERM); Land Mobile Service; Commercially available amateur radio

More information

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS Page 1 of 49 TESTT REPORT For Applicant : ACOUSTMAX INTERNATIONAL CO.., LTD Unit D16/F Cheuk Nang Plaza 250 Hennessy Road Address : WanchaiHongKong Product Name : Monster GLO Model Name : MNGLO-S, MNGLO-L,MNGLO-M,MNGLO-Mini

More information

FCC Test Report. : ASE Group 4F,No 133, Sec 4, Mingsheng E Rd, Songshan Dist, Taipei, Taiwan

FCC Test Report. : ASE Group 4F,No 133, Sec 4, Mingsheng E Rd, Songshan Dist, Taipei, Taiwan FCC Test Report Equipment : Wireless Pedometer/Tracker Brand Name : ASE Group Model No. : M903 Standard : 47 CFR FCC Part 15B Device Class : Class B Applicant Manufacturer : ASE Group 4F,No 133, Sec 4,

More information

TCN : RADIO EQUIPMENTS OPERATING IN THE 2.4 ghz BAND and USING SPREAD SPECTRUM MODULATION TECHNIQUES. Technical Requirements

TCN : RADIO EQUIPMENTS OPERATING IN THE 2.4 ghz BAND and USING SPREAD SPECTRUM MODULATION TECHNIQUES. Technical Requirements TCN 68-242: 2006 RADIO EQUIPMENTS OPERATING IN THE 2.4 ghz BAND and USING SPREAD SPECTRUM MODULATION TECHNIQUES Technical Requirements 29 CONTENTS FOREWORD... 31 1. Scope...32 2. Normative References...32

More information

ETSI EN V1.2.1 ( )

ETSI EN V1.2.1 ( ) EN 300 113-2 V1.2.1 (2002-04) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land mobile service; Radio equipment intended

More information

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C TEST REPORT For RFID READER/WRITER In conformity with FCC CFR 47 Part15 Subpart C Model: TR3XM-SD01 / TR3XM-SU01 / TR3XM-SN01 FCC ID: MK4TR3XM-SX01 Test Item: RFID READER/WRITER Report No: RY1203Z12R1

More information

AS/NZS TEST REPORT. : Wireless IR Repeater System

AS/NZS TEST REPORT. : Wireless IR Repeater System AS/NZS TEST REPORT Equipment : Wireless IR Repeater System Model No. : A-1369 I HEREBY CERTIFY THAT : The sample was received on Dec. 01, 2016 and the testing was carried out on Dec. 01, 2016 at Cerpass

More information

Test Report No

Test Report No x Test Report No.8312314587 For Synel Industries Ltd. Equipment Under Test: Proximity Reader From The Standards Institution Of Israel Industry Division Telematics Laboratory EMC Section Certificate No.

More information

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station Page 20 of 51 Pages 7.5. Conducted spurious emission 7.5.1. Requirements: Clause 15.247(d). In any 100 khz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional

More information

ETSI EN V1.3.1 ( )

ETSI EN V1.3.1 ( ) EN 300 341-1 V1.3.1 (2000-12) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile service (RP 02); Radio equipment using an integral

More information

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement... TABLE OF CONTENTS 1. SUMMARY OF TEST RESULTS... 4 2. GENERAL INFORMATION... 5 2.1 Details of E.U.T.... 5 2.2 Description of Support Device... 5 2.3 Block Diagram of Test Setup... 5 2.4 Test Facility...

More information

Global United Technology Services Co., Ltd. SPECTRUM REPORT SHENZHEN WLINK TECHNOLOGY CO., LIMITED

Global United Technology Services Co., Ltd. SPECTRUM REPORT SHENZHEN WLINK TECHNOLOGY CO., LIMITED Report No.: GTS201712000042E02 SPECTRUM REPORT Applicant: Address of Applicant: Manufacturer/Factory: SHENZHEN WLINK TECHNOLOGY CO., LIMITED 319, YiBen Electronic Business Building, NO.1063 ChaGuang Road,

More information

ETSI TS V1.1.1 ( )

ETSI TS V1.1.1 ( ) TS 100 220-1 V1.1.1 (1999-10) Technical Specification Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRDs); Measurement Specification for Wideband Transmitter Stability

More information

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( ) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment with an internal or external RF connector

More information

SPECTRUM REPORT Dragino Technology Co., Limited

SPECTRUM REPORT Dragino Technology Co., Limited Report No.: GTS201705000186E03 Applicant: SPECTRUM REPORT Dragino Technology Co., Limited Address of Applicant: Manufacturer/ Factory: Room 1101, City Invest Commercial Center, No.546 QingLinRoad, LongCheng

More information

Description of Test Facility

Description of Test Facility Description of Test Facility Name: Address: Intertek Testing Services Limited Shanghai Building No.86, 1198 Qinzhou Road(North), Shanghai 200233, P.R. China FCC Registration Number: 236597 IC Assigned

More information

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042 XBee Series 2 OEM RF Module Model No.: XBEE2 Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042 In Accordance With Federal Communications Commission (FCC) Part 15, Subpart C, Section

More information

ETSI EN V1.3.1 ( )

ETSI EN V1.3.1 ( ) EN 300 220-1 V1.3.1 (2000-09) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the

More information

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS TABLE OF CONTENTS 1. SUMMARY OF TEST RESULTS... 4 2. GENERAL INFORMATION... 5 2.1 Details of E.U.T.... 5 2.2 Description of Support Device... 5 2.3 Block Diagram of Test Setup... 5 2.4 Test Facility...

More information

G.S.D. S.r.l. Via Marmiceto, Pisa (loc. Ospedaletto) Italy MARKING. Test Report n. FCC CAEN RFID S.r.l Viareggio (LU) Italy

G.S.D. S.r.l. Via Marmiceto, Pisa (loc. Ospedaletto) Italy MARKING. Test Report n. FCC CAEN RFID S.r.l Viareggio (LU) Italy MARKING Laboratories ELECTROMAGNETIC COMPATIBILITY ELECTRICAL SAFETY LASER SPECTROSCOPY ENVIRONMENTAL PHYSICS G.S.D. Srl PISA - Italy Test Report n. FCC-17337 Manufacturer Address CAEN RFID S.r.l. Test

More information

FCC Part 90 Rules Test Report

FCC Part 90 Rules Test Report Page 1 of 147 FCC Part 90 Rules Test Report FCC ID : POD-DMR2 PRODUCT DESIGNATION : DMR Digital Transceiver BRAND NAME : TYT MODEL NAME : MD-2017, MD-760 CLIENT : TYT ELECTRONICS CO., LTD DATE OF ISSUE

More information

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947 EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947 7.1 RF Power -- Pursuant to 47 CFR 2.947(c) Method of Conducted Output Power Measurement: Adaptation of TIA/EIA-603-A clause 2.2.1 for Pulsed Measurements

More information

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD. TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD. Test Of: Wood & Douglas Ltd ST500 Transmitter Test Report Serial No: RFI/EMCB2/RP39403B This Test Report supersedes RFI Test Report No.: RFI/EMCB1/RP39403B

More information

TABLE OF CONTENTS. Report No.: SZ E01 1. GENERAL INFORMATION... 3

TABLE OF CONTENTS. Report No.: SZ E01 1. GENERAL INFORMATION... 3 TABLE OF CONTENTS 1. GENERAL INFORMATION... 3 1.1 EUT Description... 3 1.2 Test Standards and Results... 3 1.3 Test Equipments Used... 4 1.4 Facilities and Accreditations... 4 1.4.1 Facilities... 4 1.4.2

More information

TEST REPORT Part 95(A/B) & IC RSS-210(Issue 8)

TEST REPORT Part 95(A/B) & IC RSS-210(Issue 8) TEST REPORT Part 95(A/B) & IC RSS-210(Issue 8) Equipment Under Test FRS / GMRS Model Name LXT600 FCC ID MMALXT600 IC Certification 3690A- LXT600 Applicant Midland Radio Corporation Manufacturer Global

More information

ETSI EN V2.2.1 ( )

ETSI EN V2.2.1 ( ) EN 302 054 V2.2.1 (2018-02) HARMONISED EUROPEAN STANDARD Meteorological Aids (Met Aids); Radiosondes to be used in the 400,15 MHz to 406 MHz frequency range with power levels ranging up to 200 mw; Harmonised

More information

Measurement Procedure & Test Equipment Used

Measurement Procedure & Test Equipment Used Measurement Procedure & Test Equipment Used Except where otherwise stated, all measurements are made following the Electronic Industries Association (EIA) Minimum Standard for Portable/Personal Land Mobile

More information

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST... Table of Contents 1. GENERAL INFORMATION... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST... 4 1.2 RELATED SUBMITTAL(S) / GRANT (S)... 7 1.3 TEST METHODOLOGY... 7 1.4 EQUIPMENT MODIFICATIONS... 7

More information

M1.13.EMC.0045/49277

M1.13.EMC.0045/49277 EUROFINS MODULO UNO SpA VIA CUORGNÈ, 21-10156 TORINO ITALY LABORATORY: STRADA COMUNALE SAVONESA, 9 15050 FRAZ. RIVALTA SCRIVIA - TORTONA (AL) ITALY www.eurofins-modulouno.com - info@modulouno.it TEST REPORT

More information

ETSI EN V2.1.2 ( )

ETSI EN V2.1.2 ( ) EN 300 086 V2.1.2 (2016-08) HARMONISED EUROPEAN STANDARD Land Mobile Service; Radio equipment with an internal or external RF connector intended primarily for analogue speech; Harmonised Standard covering

More information

CE Test Report. : Bluetooth 4.2 module (BLE only) (Refer to item for more details)

CE Test Report. : Bluetooth 4.2 module (BLE only) (Refer to item for more details) CE Test Report Equipment Model No. Brand Name Applicant Address : Bluetooth 4.2 module (BLE only) : BL652-SA, BL652-SC (Refer to item 1.1.1 for more details) : Laird Technologies : Laird Technologies :

More information

ETSI EN V1.2.1 ( )

ETSI EN V1.2.1 ( ) EN 302 454-1 V1.2.1 (2015-10) EUROPEAN STANDARD Meteorological Aids (Met Aids); Radiosondes to be used in the 1 668,4 MHz to 1 690 MHz frequency range; Part 1: Technical characteristics and test methods

More information

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial Page (2 ) of (34) Revision history Revision Date of issue Test report No. Description - 2014.08.25 Initial Page (3 ) of (34) TABLE OF CONTENTS 1. General information... 4 1.1. EUT description... 4 1.2.

More information

REPORT REVISION HISTORY...

REPORT REVISION HISTORY... Reference No.: WTS17S0579239E Page 2 of 39 2 Contents Page 1 COVER PAGE... 1 2 CONTENTS... 2 3 REPORT REVISION HISTORY... 3 4 GENERAL INFORMATION... 4 4.1 GENERAL DESCRIPTION OF E.U.T.... 4 4.2 DETAILS

More information

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C. Test Report Product Name Model No. Wireless LAN Card MS-6877 Applicant Address MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C. Date of Receipt June 14, 2006 Issued

More information

SPECTRUM REPORT SHENZHEN WLINK TECHNOLOGY CO., LIMITED. *In the configuration tested, the EUT complied with the standards specified above.

SPECTRUM REPORT SHENZHEN WLINK TECHNOLOGY CO., LIMITED. *In the configuration tested, the EUT complied with the standards specified above. SPECTRUM REPORT Report : GTS201807000209E03 Applicant: Address of Applicant: Manufacturer/Factory: SHENZHEN WLINK TECHNOLOGY CO., LIMITED 319, YiBen Electronic Business Building, NO.1063 ChaGuang Road,

More information

Draft ETSI EN V1.4.1 ( )

Draft ETSI EN V1.4.1 ( ) Draft EN 300 296-1 V1.4.1 (2012-07) European Standard Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment using integral antennas intended primarily for

More information

EN V1.2.2 ( )

EN V1.2.2 ( ) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Technical characteristics and test methods

More information

ETSI EN V2.1.1 ( )

ETSI EN V2.1.1 ( ) EN 300 220-1 V2.1.1 (2006-04) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the

More information

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement... TABLE OF CONTENTS 1. SUMMARY OF TEST RESULTS... 4 2. GENERAL INFORMATION... 5 2.1 Details of E.U.T.... 5 2.2 Description of Support Device... 6 2.3 Block Diagram of Test Setup... 6 2.4 Test Facility...

More information

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba FCC ID. AZPT10CG-24G Page 1 of 56 APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba Prepared for : Futaba Corporation 1080

More information

ACCORDING TO: FCC part 15 subpart C, and subpart B FOR:

ACCORDING TO: FCC part 15 subpart C, and subpart B FOR: Electrical Hermon Laboratories Ltd. P.O.Box 23, Binyamina 30500, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: mail@hermonlabs.com TEST REPORT ACCORDING TO: FCC part 15 subpart C, 15.247 and subpart

More information

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8 Page 1 of 19 APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 Prepared for : Carewell Electric Technology (Zhongshan) Co., Ltd.

More information

RF test report AU01+W02

RF test report AU01+W02 Customer: Kehlbergstrasse 109 8054 Graz Austria Tel.: +43 664 415 6260 RF test report 170186-AU01+W02 The test result refers exclusively to the tested model. This test report may not be copied or published

More information

ETSI EN V2.3.1 ( ) Harmonized European Standard (Telecommunications series)

ETSI EN V2.3.1 ( ) Harmonized European Standard (Telecommunications series) EN 300 220-2 V2.3.1 (2010-02) Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used

More information

FCC Part 90 Rules Test Report

FCC Part 90 Rules Test Report Page 1 of 147 FCC Part 90 Rules Test Report FCC ID : POD-DMR2 PRODUCT DESIGNATION : DMR Digital Transceiver BRAND NAME : TYT MODEL NAME : MD-2017, MD-760 CLIENT : TYT ELECTRONICS CO., LTD DATE OF ISSUE

More information

ENGINEERING TEST REPORT # C LSR Job #: C-2411 Compliance Testing of: RM186-SM

ENGINEERING TEST REPORT # C LSR Job #: C-2411 Compliance Testing of: RM186-SM W66 N220 Commerce Court Cedarburg, WI 53012 USA Phone: 262.375.4400 Fax: 262.375.4248 www.lsr.com ENGINEERING TEST REPORT # 316062C LSR Job #: C-2411 Compliance Testing of: RM186-SM Test Date(s): 3-28-16

More information

FCC Part 22H & 24E Measurement and Test Report

FCC Part 22H & 24E Measurement and Test Report FCC Part 22H & 24E Measurement and Test Report For Shenzhen Concox Information Technology Co., Ltd Floor 4th, Building B, Gaoxinqi Industrial Park, Liuxian 1st Road, District 67, Bao an, Shenzhen, China

More information

EUROFINS PRODUCT SERVICE GMBH EN V Tracking solution. Bolero-LT2

EUROFINS PRODUCT SERVICE GMBH EN V Tracking solution. Bolero-LT2 EUROFINS PRODUCT SERVICE GMBH RADIO TEST-REPORT EN 300 440 V1.4.1 Tracking solution Bolero-LT2 TEST REPORT NUMBER: G0M-1103-1037-T-42 Eurofins Product Service GmbH Storkower Str. 38c, 15526 Reichenwalde,

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( ) EN 300 219-2 V1.1.1 (2001-03) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment transmitting

More information

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co. TEST REPORT Applicant Address Shenzhen Innokin Technology Co., Ltd Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China Manufacturer or Supplier Address Product

More information

TRANSMITTER MODEL: KAS-2030M

TRANSMITTER MODEL: KAS-2030M Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for TRANSMITTER MODEL: KAS-2030M Prepared for WILDLIFE TECHNOLOGIES 115 WOLCOTT STREET MANCHESTER, NEW HAMPSHIRE 03103 Prepared by: KYLE FUJIMOTO Approved

More information

RF Test Report. Report No.: AGC EE10. TEST NAME : 1999/5/EC R&TTE Directive Art.3.2 STANDARD(S) : EN V : V1.

RF Test Report. Report No.: AGC EE10. TEST NAME : 1999/5/EC R&TTE Directive Art.3.2 STANDARD(S) : EN V : V1. Page 1 of 49 RF Test Report Report No.: AGC05278160201EE10 TEST NAME : 1999/5/EC R&TTE Directive Art.3.2 PRODUCT DESIGNATION : ihere3.0 BRAND NAME : ihere3.0 MODEL NAME : ihere3.0 CLIENT : No NDA Inc.

More information

ETSI TS V1.1.1 ( )

ETSI TS V1.1.1 ( ) TS 102 903 V1.1.1 (2011-08) Technical Specification Electromagnetic compatibility and Radio spectrum Matters (ERM); Compliance tests for cognitive interference mitigation for use by UHF RFID using Detect-And-Avoid

More information

SHURE ELECTROMAGNETIC COMPATIBILITY LABORATORY TEST REPORT

SHURE ELECTROMAGNETIC COMPATIBILITY LABORATORY TEST REPORT SHURE ELECTROMAGNETIC COMPATIBILITY LABORATORY TEST REPORT TEST REPORT TITLE: Electromagnetic Compatibility Tests of the Shure QLXD2-V50 Handheld Transmitter TEST ITEM DESCRIPTION: QLXD2-V50 is a digital

More information

RADIOCOMMUNICATIONS TESTING

RADIOCOMMUNICATIONS TESTING 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Telephone: (852) 2173 8888 Facsimile: (852) 2785 5487 www.intertek.com RADIOCOMMUNICATIONS TESTING NPD LTD. 73020R WALKIE TALKIES : TEST

More information

ETSI EN V1.3.2 ( )

ETSI EN V1.3.2 ( ) EN 300 330-1 V1.3.2 (2002-12) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment in the frequency range

More information

Verification of Conformity On Behalf of

Verification of Conformity On Behalf of Verification of Conformity On Behalf of EVERPRO TECHNOLOGIES COMPANY LTD. HDMI Active optical Cable Model No.: HDMI OPTICAL FIBER CABLE 330FT, 300FT, 250FT, 200FT, 150FT, 100FT, 50FT Prepared for : EVERPRO

More information

EUROFINS PRODUCT SERVICE GMBH EN V1.6.1 EN V Asset tracker. Rock

EUROFINS PRODUCT SERVICE GMBH EN V1.6.1 EN V Asset tracker. Rock EUROFINS PRODUCT SERVICE GMBH RADIO TEST- REPORT EN 300 440-1 V1.6.1 EN 300 440-2 V1.4.1 Asset tracker Rock TEST REPORT NUMBER: G0M-1103-1036-T-42 Eurofins Product Service GmbH Storkower Str. 38c, 15526

More information

Test Report. Prepared for: Becker Avionics, Inc. Model: TG Description: Aeronautical basestation radio used for emergencies

Test Report. Prepared for: Becker Avionics, Inc. Model: TG Description: Aeronautical basestation radio used for emergencies Test Report Prepared for: Becker Avionics, Inc Model: TG660-50 Description: Aeronautical basestation radio used for emergencies Serial Number: 10001, 10002 FCC ID: 2AHX9TG660 To FCC Part 87 Date of Issue:

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00097-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China Report

More information

TEST REPORT. : Masterbuilt Manufacturing Inc. 1 Masterbuilt Court Columbus, Georgia, 31907, USA

TEST REPORT. : Masterbuilt Manufacturing Inc. 1 Masterbuilt Court Columbus, Georgia, 31907, USA Applicant Name & Address Sample Description Product TEST REPORT Report No.: 170527172GZU-001 : Masterbuilt Manufacturing Inc. 1 Masterbuilt Court Columbus, Georgia, 31907, USA : 30 inch Electric Smoker

More information

RSS-247 TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Home Audio System. Model No.: GTK-XB7 IC: 409B-GTKXB7

RSS-247 TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Home Audio System. Model No.: GTK-XB7 IC: 409B-GTKXB7 IC:409B-GTKXB7 RSS-247 TEST REPORT FOR CERTIFICATION On Behalf of Sony Corporation Home Audio System Model No.: GTK-XB7 IC: 409B-GTKXB7 Prepared for : Sony Corporation 1-7-1 Konan, Minato-ku, Tokyo 108-0075

More information

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20 Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB

More information

RF TEST REPORT UAB TELTONIKA 2AJLOTM2500TLT TELTONIKA TM2500 RXA RF02R2

RF TEST REPORT UAB TELTONIKA 2AJLOTM2500TLT TELTONIKA TM2500 RXA RF02R2 RF TEST REPORT Applicant FCC ID Brand Product Model Report No. UAB TELTONIKA 2AJLOTM2500TLT TELTONIKA GSM/GPRS/GNSS/BLUETOOTH module TM2500 RXA1606-0123RF02R2 Issue Date November 23, 2016 TA Technology

More information

FCC Test Report. : Wireless Way Richmond, BC, V6V 3A4 Canada : 47 CFR FCC Part 27 Subpart L

FCC Test Report. : Wireless Way Richmond, BC, V6V 3A4 Canada : 47 CFR FCC Part 27 Subpart L FCC Test Report FCC ID Equipment Model No. Brand Name Applicant Address Standard : N7NHL7688 : Wireless Module : HL7688 : AirPrime : Sierra Wireless Inc. Received Date : Jul. 12, 2016 : 13811 Wireless

More information

EMC Test Report. Report No.: AGC EE01 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.

EMC Test Report. Report No.: AGC EE01 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO. Page 1 of 38 EMC Test Report PRODUCT DESIGNATION BRAND NAME MODEL NAME CLIENT : Dual Band Mobile Radio : VGC : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.,LTD DATE

More information

Summary 18/03/ :27:42. Differences exist between documents. Old Document: en_ v010501p 17 pages (97 KB) 18/03/ :27:35

Summary 18/03/ :27:42. Differences exist between documents. Old Document: en_ v010501p 17 pages (97 KB) 18/03/ :27:35 Summary 18/03/2016 16:27:42 Differences exist between documents. New Document: en_30067602v020101p 16 pages (156 KB) 18/03/2016 16:27:36 Used to display results. Old Document: en_30067602v010501p 17 pages

More information

Final draft ETSI EN V1.4.1 ( )

Final draft ETSI EN V1.4.1 ( ) Final draft EN 302 208-1 V1.4.1 (2011-07) European Standard Electromagnetic compatibility and Radio spectrum Matters (ERM); Radio Frequency Identification Equipment operating in the band 865 MHz to 868

More information

EUROPEAN ETS TELECOMMUNICATION November 1996 STANDARD

EUROPEAN ETS TELECOMMUNICATION November 1996 STANDARD EUROPEAN ETS 300 328 TELECOMMUNICATION November 1996 STANDARD Second Edition Source: ETSI TC-RES Reference: RE/RES-10-09 ICS: 33.060.20 33.060.50 Key words: Data, emission, mobile, radio, spread spectrum,

More information

ETSI EN V1.1.1 ( ) European Standard (Telecommunications series)

ETSI EN V1.1.1 ( ) European Standard (Telecommunications series) EN 302 510-1 V1.1.1 (2007-07) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Radio equipment in the frequency range 30 MHz to 37,5 MHz for

More information

EN V1.2.1 ( )

EN V1.2.1 ( ) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Technical characteristics and test methods for radio equipment to be used

More information

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera VCCI TEST REPORT According to Class B ITE Equipment : USB video camera Model No. : V-U0011 Applicant : Logitech Far East Ltd. 2 Creation Road IV, Science-Based Ind. Park, Hsinchu, Taiwan. The test result

More information

FCC C2PC Test Report

FCC C2PC Test Report FCC C2PC Test Report FCC ID Equipment Model No. Brand Name Applicant : SQGBT800 : BTv4.0 Dual Mode USB Dongle : BT820 : Laird Technologies : Laird Technologies Address : 11160 Thompson Ave. / Lenexa, Kansas

More information

Version TEST REPORT NO. DATE DESCRIPTION. HCTR1208FR50 August 29, 2012 First Approval Report

Version TEST REPORT NO. DATE DESCRIPTION. HCTR1208FR50 August 29, 2012 First Approval Report Version TEST REPORT NO. DATE DESCRIPTION First Approval Report Page 2 of 101 Table of Contents 1. GENERAL INFORMATION... 4 2. INTRODUCTION... 5 2.1. EUT DESCRIPTION... 5 2.2. MEASURING INSTRUMENT CALIBRATION...

More information

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021 VCCI TEST REPORT According to V-3/2009.04, TECHNICAL REQUIREMENTS, Class B ITE Equipment : USB video camera Model No. : V-U0017 / V-U0021 Applicant : Logitech Far East Ltd. 2 Creation Road IV, Science-Based

More information

FCC CERTIFICATION TEST REPORT

FCC CERTIFICATION TEST REPORT Report No:DDT-RE120176 Issued Date: 2013/01/05 FCC CERTIFICATION TEST REPORT FOR Applicant : AliMed Inc. Address : 297 High St Dedham Ma 02026 Equipment under Test : Alert transmitter Model No : #712716

More information

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( ) EN 300 341-2 V1.1.1 (2000-12) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile service (RP 02); Radio equipment

More information