Digital Multimeter. GDM-8200A Series USER MANUAL GW INSTEK PART NO. 82DM-8255A3A1 ISO-9001 CERTIFIED MANUFACTURER

Size: px
Start display at page:

Download "Digital Multimeter. GDM-8200A Series USER MANUAL GW INSTEK PART NO. 82DM-8255A3A1 ISO-9001 CERTIFIED MANUFACTURER"

Transcription

1 Digital Multimeter GDM-8200A Series USER MANUAL GW INSTEK PART NO. 82DM-8255A3A1 ISO-9001 CERTIFIED MANUFACTURER

2 This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will company. The information in this manual was correct at the time of printing. However, Good Will continues to improve products and reserves the right to change specifications, equipment, and maintenance procedures at any time without notice. Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng City, Taipei County 236, Taiwan.

3 Table of Contents Table of Contents SAFETY INSTRUCTIONS...5 Safety Symbols...5 Safety Guidelines...6 GETTING STARTED...9 GDM-8200A Series Lineup GDM-8200A Series Characteristics Front Panel Overview Rear Panel Overview Set Up BASIC MEASUREMENT...21 Basic Measurement Overview AC/DC/AC+DC Voltage Measurement AC/DC/AC+DC Current Measurement W/4W Resistance Measurement Diode Test Continuity Test Frequency/Period Measurement Temperature Measurement ADVANCED MEASUREMENT...40 Advanced Measurement Overview dbm/db Measurement Max/Min Measurement Relative Value Measurement Hold Measurement Compare Measurement Math Measurement Dual Display Measurement SYSTEM/DISPLAY CONFIGURATION...57 Refresh Rate Setting Trigger Setting

4 GDM-8200A Series User Manual Digital Filter Setting...62 Display Setting...64 STORE/RECALL Store Measurement Record...67 Recall Measurement Record...68 Save Instrument Settings...69 Recall Instrument Settings...70 SCANNER (OPTIONAL) GDM-SC1 Scanner Specifications...72 Scanner Installation...72 Setup Scan...79 Run Scan...86 DIGITAL I/O Digital I/O Terminal Configuration...90 REMOTE CONTROL Configure Interface...95 Command Syntax...98 Command Set...99 FAQ APPENDIX Firmware Version Fuse Replacement Specifications EC Declaration of Conformity INDEX

5 SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS This chapter contains important safety instructions that you must follow when operating the GDM-8200A series and when keeping them in storage. Read the following before any operation to insure your safety and to keep the best condition for the GDM-8200A series. Safety Symbols These safety symbols may appear in this manual or on the GDM-8200A series. WARNING CAUTION Warning: Identifies conditions or practices that could result in injury or loss of life. Caution: Identifies conditions or practices that could result in damage to the GDM-8200A series or to other properties. DANGER High Voltage Attention Refer to the Manual Protective Conductor Terminal Earth (ground) Terminal 5

6 GDM-8200A Series User Manual Safety Guidelines General Guideline CAUTION Power Supply WARNING Make sure that the voltage input level does not exceed DC1000V/AC750V. Make sure the current input level does not exceed 10A. Do not place any heavy object on the GDM-8200A series. Avoid severe impacts or rough handling that leads to damaging the GDM-8200A series. Do not discharge static electricity to the GDM-8200A series. Use only mating connectors, not bare wires, for the terminals. Do not block or obstruct the cooling fan vent opening. Do not perform measurement at the source of low-voltage installation or at building installations (Note below). Do not disassemble the GDM-8200A series unless you are qualified as service personnel. (Note) EN :2001 specifies the measurement categories and their requirements as follows. The GDM-8200A series fall under category I or II. Measurement category IV is for measurement performed at the source of low-voltage installation. Measurement category III is for measurement performed in the building installation. Measurement category II is for measurement performed on the circuits directly connected to the low voltage installation. Measurement category I is for measurements performed on circuits not directly connected to Mains. AC Input voltage: V AC, 50 60Hz The power supply voltage should not fluctuate more than 10%. Connect the protective grounding conductor of the AC power cord to an earth ground, to avoid electrical shock. 6

7 SAFETY INSTRUCTIONS Fuse WARNING Cleaning the GDM-8200A series Operation Environment Storage Environment Fuse type: T3.15A/ 250V Make sure the correct type of fuse is installed before power up. To ensure fire protection, replace the fuse only with the specified type and rating. Disconnect the power cord before fuse replacement. Make sure the cause of fuse blowout is fixed before fuse replacement. Disconnect the power cord before cleaning. Use a soft cloth dampened in a solution of mild detergent and water. Do not spray any liquid into the GDM-8200A series. Do not use chemical or cleaner containing harsh material such as benzene, toluene, xylene, and acetone. Location: Indoor, no direct sunlight, dust free, almost non-conductive pollution (Note below) Relative Humidity: < 75% Altitude: < 2000m Temperature: 0 C to 40 C (operation), 18 C to 28 C (full accuracy) (Note) EN :2001 specifies the pollution degrees and their requirements as follows. the GDM-8200A series falls under degree 2. Pollution refers to addition of foreign matter, solid, liquid, or gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity. Pollution degree 1: No pollution or only dry, non-conductive pollution occurs. The pollution has no influence. Pollution degree 2: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected. Pollution degree 3: Conductive pollution occurs, or dry, non-conductive pollution occurs which becomes conductive due to condensation which is expected. In such conditions, equipment is normally protected against exposure to direct sunlight, precipitation, and full wind pressure, but neither temperature nor humidity is controlled. Location: Indoor Relative Humidity: < 75% (0~35 C), <50% (35~50 C) Temperature: 10 C to 70 C 7

8 GDM-8200A Series User Manual Power cord for the United Kingdom When using the GDM-8200A series in the United Kingdom, make sure the power cord meets the following safety instructions. NOTE: This lead / appliance must only be wired by competent persons WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code: Green/ Yellow: Earth Blue: Neutral Brown: Live (Phase) As the colours of the wires in main leads may not correspond with the colours marking identified in your plug/appliance, proceed as follows: The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with the letter E or by the earth symbol or coloured Green or Green & Yellow. The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black. The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red. If in doubt, consult the instructions provided with the equipment or contact the supplier. This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, cable of 0.75mm2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used. Any moulded mains connector that requires removal /replacement must be destroyed by removal of any fuse & fuse carrier and disposed of immediately, as a plug with bared wires is hazardous if a engaged in live socket. Any re-wiring must be carried out in accordance with the information detailed on this label. 8

9 GETTING STARTED GETTING STARTED This chapter describes the GDM-8200A series in a nutshell, including its main features, package contents, and front / rear / display panel introduction. After going through the overview, follow the Power-up sequence and Functionality check section to properly setup the GDM-8200A series. Please note the information in this manual was correct at the time of printing. However as GWInstek continues to improve its products, changes can occur at any time without notice. Please see the GWInstek website for the latest information and content. Characteristics GDM-8200A Series Lineup...10 GDM-8200A Series Characteristics...11 Panel Overview Front Panel Overview...12 Measurement keys (Upper row)...13 Measurement keys (Lower row)...15 Rear Panel Overview...17 Setup Tilt Stand...19 Power Up

10 GDM-8200A Series User Manual GDM-8200A Series Lineup The GDM-8200A series consists of two models: GDM-8251A and GDM-8255A. Appearance Both two models are identical except for the model name and the meter count of the 1 st display. Models GDM-8251A 1 st display meter: 120,000 counts GDM-8255A 1 st display meter: 199,999 counts 10

11 GETTING STARTED GDM-8200A Series Characteristics The GDM-8200A series are portable, dual-display digital multimeters suitable for wide range of applications, such as production testing, research, and field verification. Performance High DCV accuracy: 0.012% High current range: 10A High Voltage range: 1000V High ACV frequency response: 100kHz Features Interface Optional Items meter count (GDM-8251A) meter count (GDM-8255A) Multi functions: ACV, DCV, ACI, DCI, 2W/4W R, Hz, Continuity, Diode test, MAX/MIN, REL, dbm, HOLD, AutoHold, Compare. Manual or Auto ranging AC true RMS or AC + DC true RMS Voltage/Resistance/Diode/Temperature input Current input 4W sense input USB device/rs232 for remote control 9-pin digital I/O 16 channel scanner x2 (optional) 16 channel scanner x 2 11

12 GDM-8200A Series User Manual Front Panel Overview Main Display Measurement key Fuse 4W Ohm Terminal Main Terminal COM Terminal DCI/ACI Terminal Power Switch Output On/Off key Power Switch Turns On or Off the main power. For power up sequence, see page20. Main Display Input fuse / 4W Ω sense LO terminal 4W Ω Sense HI Terminal Shows measurement results and parameters. For display configuration details, see page64 (light setting). As a fuse, protects the instrument from over-current. Rating: T2A, 250V. For fuse replacement procedure, see page112. As a sense terminal, accepts 4W Ω measurement LO connection. Also accepts current input less than 2A. For details, see page30. Accepts HI sense line in 4W resistance measurement. For details, see page30. 12

13 GETTING STARTED COM Terminal Accepts ground (COM) line in all measurements except the sense line in 4W Resistance (page30). Voltage/ 2W Ω / (Diode) Terminal Accepts input in all measurements except for DC/AC Current and 4W Resistance sense line. Current Terminal Accepts DC/AC Current input. For DCI/ACI details, see page28. Output On/Off key Turns the display on or off. When the display is turned off, all panel keys except the Output On/Off key become disabled. The Output On/Off key is On by default. Measurement keys (Upper row) SHIFT/EXIT ACV As the Shift key, selects the second functionality assigned to each front panel key. When pressed, the indicator appears in the display. As the Exit key, gets out of the parameter configuration mode and goes back to the measurement result display mode. Measures AC Voltage (page24). SHIFT ACV (SCAN) DCV Starts the optional scan measurement (page79). Measures DC Voltage (page24). 13

14 GDM-8200A Series User Manual SHIFT DCV (STEP) ACV + DCV ACI Starts the step measurement (page79) using the optional scanner. When the ACV key and the DCV key are pressed together, they measure AC+DC Voltage (page24). Measures AC Current (page28). SHIFT ACI (RECALL) DCI Recalls a normal measurement result (page68) or a scan measurement result (page87). Measures DC Current (page28). SHIFT DCI (STORE) ACI + DCI 2/4W (Resistance) SHIFT 2/4W (MATH) / (Diode/ Continuity) SHIFT / (dbm) Hz/P (Frequency/ Period) SHIFT + Hz/P (db) Stores a measurement result (page67). When the ACI key and the DCI key are pressed together, they measure AC+DC Current (page28). Measures 2-wire or 4-wire Resistance (page30). Enters the Math measurement mode (page52). / Tests Diode (page32) or Continuity (page33). Measures dbm (page43). Measures Frequency or Period (page36). Measures db (page44). 14

15 GETTING STARTED C/ F (Temperature) SHIFT + C/ F (SENSOR) Measures Temperature (page37). Selects the type of thermocouple used in the Temperature measurement (page38). Measurement keys (Lower row) AUTO/ENTER SHIFT AUTO (RATE) As the AUTO key, selects the measurement range automatically. As the ENTER key, confirms the entered value. Selects the measurement update rate: Slow, Medium, or Fast (page22). Up/Down HOLD SHIFT HOLD (COMPare) TRIG (Trigger) SHIFT TRIG (Int/Ext Trigger) Left/Right REL SHIFT REL (RELative base) Selects the parameter in various occasions: higher ( ) or lower ( ). Activates the Hold function (page48). Activates the Compare measurement (page49). Triggers sample acquisition manually (page59). Selects the Internal or the External trigger source (page59). Selects the parameter in various occasions: left ( ) or right ( ). Measures the Relative value (page46). Manually sets the reference value for the Relative value measurement (page46). 15

16 GDM-8200A Series User Manual MX/MN (MAX/ MIN) SHIFT MX/MN (FILTER) 2 ND (Display) / LOCAL SHIFT 2 ND (Menu) Measures the Maximum or the Minimum value (page45). Selects the digital filter type for the signal sampling (page62). As the 2 nd key, selects the measurement item on the 2 nd display (page55). Pressing and holding for more than 1 second turns off the 2 nd display. As the Local key, releases the remote control and goes back to the local panel operation (page95). Enters the configuration mode. Configures or displays the following items: Display (page57), Beep (page35), Continuity threshold (page34), Scanner (page79), Digital I/O (page89), and System information (page109). 16

17 GETTING STARTED Rear Panel Overview Optional Item Slot x2 Power Cord Socket Digital I/O Port CAL Key Port USB Device Port RS-232C Port Fuse T3.15A/250V Power Cord Socket Accepts the power cord. AC V, 50 60Hz. For power on sequence, see page20. Fuse Socket Holds the main fuse: T3.15A 250V, 20VA. For fuse replacement details, see page111. RS-232C port USB device port Accepts an RS-232C cable for remote control; DB-9 male connector. For remote control details, see page96. Accepts a USB device cable for remote control; Type A, female connector. For remote control details, see page95. CAL key port CAL KEY Reserved for internal uses as in firmware update and calibration. 17

18 GDM-8200A Series User Manual Digital I/O port Accepts a digital I/O cable for the Hi/Lo limit test; DB-9 pin, female connector. For digital I/O details, see page90. Optional slot x2 Accepts up to two optional scanner modules. 16 channels are available per scanner. When two modules are used, maximum 32 channels are available. For scanner details, see page71. 18

19 GETTING STARTED Set Up Tilt Stand Tilt stand steps Pull out the handle sideways and rotate it. Place the unit horizontally, Or in the tilt stand position. Place the handle vertically for hand carry. 19

20 GDM-8200A Series User Manual Power Up Power up steps 1. Connect the power cord to the AC Voltage input. Note Make sure the ground connector of the power cord is connected to a safety ground. This will affect the measurement accuracy. 2. Push and turn On the main power switch on the front panel. 3. The display shows the model name and the version for a few seconds. Example: GDM-8255A, V Then the default setting appears. Example: DCV, Auto, 1V range 20

21 BASIC MEASUREMENT BASIC MEASUREMENT Overview Basic Measurement Overview...22 Common attribute: refresh rate...22 Common attribute: reading indicator...23 Common attribute: manual/automatic triggering..23 Voltage AC/DC/AC+DC Voltage Measurement...24 Select Voltage range...25 Voltage conversion table...26 Crest factor table...27 Current AC/DC/AC+DC Current Measurement...28 Select Current range...29 Resistance 2W/4W Resistance Measurement...31 Diode Diode Test...33 Continuity Continuity Test...33 Set continuity threshold...34 Select beeper setting...35 Frequency/ Period Frequency/Period Measurement...36 Temperature Temperature Measurement...37 Select thermocouple type...38 Set reference junction temperature

22 GDM-8200A Series User Manual Basic Measurement Overview Background Basic measurement refers to the eight types of measurements assigned to the upper row keys on the front panel. Measurement type ACV AC Voltage DCV DC Voltage ACV+DCV AC+DC Voltage ACI AC Current DCI DC Current ACI+DCI AC+DC Current 2/4W 2-wire and 4-wire Resistance Diode/Continuity Hz/P Frequency/Period C/ F Celsius/Fahrenheit Temperature Advanced measurement Advanced measurement (page40) mainly refers to the operation using the result obtained from one or more of the basic measurement. Common attribute: refresh rate Background Refresh rate defines how frequently the GDM-8200A series captures and updates the measurement data. Faster refresh rate yields lower accuracy and resolution. Slower refresh rate yields higher accuracy and resolution. Consider these trade-offs when selecting the refresh rate. Range S 5 ½ digits M 4 ½ digits F 3 ½ digits Selection step 1. Press the Shift key followed by the AUTO (RATE) key. The refresh rate switches to the next. 22

23 BASIC MEASUREMENT 2. The refresh rate indicator shows the current status. Common attribute: reading indicator Background The reading indicator next to the 1st display flashes according to the refresh rate setting. Common attribute: manual/automatic triggering Automatic triggering (default) Manual triggering The GDM-8200A series triggers according to the refresh rate. See the previous page for refresh rate setting details. Press the TRIG key to trigger measurement manually. 23

24 GDM-8200A Series User Manual AC/DC/AC+DC Voltage Measurement Voltage type AC 0 ~ 750V DC 0 ~ 1000V AC+DC 0 ~ 1000V (AC = true RMS) 1. Activate ACV/ DCV Press the ACV (AC Voltage) key or DCV (DC Voltage) key. or For AC+DC Voltage, press the ACV key and the DCV key together. 2. ACV/DCV mode display appears AC(DC) + V AUTO 100mV Indicates AC, DC, AC+DC Voltage Indicates Automatic range selection 2nd display shows the Voltage range 3. Connect the test lead and measure Connect the test lead between the V and the COM port. The display updates the reading. V COM Note When measuring in1000v (maximum) range immediately followed by 100mV (minimum) range, an error might occur due to extreme range switching. In such case, take at least one minute in between as an interval. 24

25 BASIC MEASUREMENT Select Voltage range Auto range Manual range Selection list Note To turn the automatic range selection On/Off, press the AUTO key. Press the Up or the Down key to select the range. AUTO indicator turns Off automatically. If the appropriate range is unknown, select the highest range. Range Resolution / Full slow rate Resolution Full scale Full scale (GDM-8251A) (GDM-8255A) 100mV 1µV mV mV 1V 10µV V V 10V 100µV V V 100V 1mV V V 750V (AC) 10mV V V 1000V (DC, AC+DC) 10mV V V For more detailed parameters, see the specifications at page

26 GDM-8200A Series User Manual Voltage conversion table This table shows the relationship between AC, DC, and AC+DC reading in various waveforms. Waveform Peak to Peak AC (True RMS) DC AC + DC (True RMS) Sine PK-PK Rectified Sine (full wave) PK-PK Rectified Sine (half wave) PK-PK Square PK-PK Rectified Square PK-PK Rectangular Pulse X Y PK-PK K 2) K= ( D D D=X/Y 2D D=X/Y 2 D D=X/Y Triangle Sawtooth PK-PK 26

27 BASIC MEASUREMENT Crest factor table Background Crest factor is the ratio of the peak signal amplitude to the RMS value of the signal. It determines the accuracy of AC measurement. If the crest factor is less than 3.0, voltage measurement will not result in error due to dynamic range limitations at full scale. If the crest factor is more than 3.0, it usually indicates abnormal waveform as seen from the below table. Waveform Shape Crest factor Square wave 1.0 Sine wave Triangle sawtooth Mixed frequencies SCR output 100% ~ 10% ~ ~ 3.0 White noise 3.0 ~ 4.0 AC Coupled pulse train 3.0 Spike >9.0 27

28 GDM-8200A Series User Manual AC/DC/AC+DC Current Measurement Current type AC 0 ~ 10A DC 0 ~ 10A AC+DC 0 ~ 10A (AC = true RMS) 1. Activate ACV/ DCV Press the ACI (AC Current) key or the DCI (DC Current) key. or For AC+DC Current, press the ACI key and the DCI key together. 2. ACI/DCI mode display appears AC(DC) + A Indicates AC, DC, AC+DC Current (Note: AC = true RMS) AUTO 10A Indicates Automatic range selection 2nd display shows the Current range 3. Connect the test lead and measure Connect the test lead between the A and COM port or LO to COM port, depending on the current. For current 2A use the LO port; For current up to 10A use the A port. The display updates the reading. LO MAX 2A COM A 28

29 BASIC MEASUREMENT Select Current range Auto range Manual range Selection list Note To turn the automatic range selection On/Off, press the AUTO key. Press the Up or the Down key to select the range. AUTO indicator turns Off automatically. If the appropriate range is unknown, select the highest range. Range Resolution / Full slow rate Resolution Full scale Full scale (GDM-8251A) (GDM-8255A) 10mA 0.1µA mA mA 100mA 1µA mA mA 1A 100µA A A 10A 100µA A A *10A range is not available for AC+DC Current. For more detailed range, see the specifications at page

30 GDM-8200A Series User Manual 2W/4W Resistance Measurement Measurement type 2-wire 4-wire Uses the standard V-COM ports. Recommended for measuring resistances larger than 1kΩ. Compensates the test lead effect using the 4W compensation ports, in addition to the standard V-COM ports. Recommended for measuring sensitive resistances smaller than 1kΩ. 1. Activate resistance measurement For 2-wire resistance measurement, press the 2W/4W key once. For 4-wire resistance measurement, press the 2W/4W key twice. 2. 2W resistance mode display appears 2W(4W) + Ω Indicates 2W(4W) Resistance AUTO Indicates Automatic range selection 10M 2nd display shows the Resistance range 3. Connect the test lead and measure Connect the test lead. For 2-wire resistance, use the V and the COM port. For 4-wire resistance, use the V and the COM port, plus the 4W sense, and LO port for sensing. The display updates the reading. 2W connection 4W connection 4W SENSE COM LO COM 30

31 BASIC MEASUREMENT Select Resistance range Auto range Manual range To turn the automatic range selection On/Off, press the AUTO key. Press the Up or the Down key to select the range. AUTO indicator turns Off automatically. If the range is unknown, select the highest range. Selection list Range Full slow rate GDM-8251A GDM-8255A 100Ω Ω Ω 1kΩ kΩ kΩ 10kΩ kΩ kΩ 100kΩ kΩ kΩ 1MΩ MΩ MΩ 10MΩ MΩ MΩ 100MΩ MΩ MΩ Note For more detailed range, see the specifications at page

32 GDM-8200A Series User Manual Diode Test Background Diode test checks the forward bias characteristics of a diode by running a constant forward bias current, approx. 0.5mA, through the DUT. 1. Activate diode test 2. Diode mode display appears Press the key once. DIODE + V Indicates Diode test 2nd display shows the title 3. Connect the test lead and measure Connect the test lead between the and COM port; Anode-V, Cathode-COM. The display updates the reading. COM 32

33 BASIC MEASUREMENT Continuity Test Background Continuity test checks that the resistance in the DUT is low enough to be considered continuous (of conductive nature). 1. Activate continuity test 2. Continuity mode display appears Press the key twice. CONT + Ω Indicates Continuity test 2nd display shows the title 3. Connect the test lead and measure Connect the test lead between the Ω and the COM port. The display updates the reading. COM 33

34 GDM-8200A Series User Manual Set continuity threshold Background Continuity threshold defines the maximum resistance allowed in the DUT when testing the continuity. Threshold Range 0 ~ 1000Ω, 1Ω resolution, 10Ω default 1. Activate threshold setting 1. Press the Shift key, the 2ND key, the Right key. The measurement menu appears. 2. Press the Down key, the Right key, the Enter key. The continuity threshold setting appears. 2. Edit threshold 1. Move the cursor (the flashing digit) using the Left/Right key. 2. Change the value using the Up/Down key. Range: 1 ~ 1000Ω, 1Ω resolution, default 10Ω 3. Go back to the default display Press the Enter key to confirm the edited threshold. Press the Exit key to go back to the default display. 34

35 BASIC MEASUREMENT Select beeper setting Background Beeper setting defines how the GDM-8200A series notifies the continuity test result to the user. Beeper parameter Pass Fail Off Beeps when the test result is pass Beeps when the test result is fail Beep function is turned Off 1. Activate beeper setting menu 1. Press the Shift key followed by the 2nd (Menu) key. The system menu appears. 2. Press the Down key. The beep menu appears. 3. Press the Down key. The beep setting appears. 2. Select the beep setting 3. Go back to the default display To change the setting, press the Up/Down key. Beeper type: Pass (beep when pass), Fail (beep when fail, default), Off (beep off) Press the Enter key to confirm. Press the Exit key to go back to the default display. 35

36 GDM-8200A Series User Manual Frequency/Period Measurement 1. Activate frequency/period measurement 2. Frequency (Period) mode display appears To measure Frequency, press the Hz/P key once. To measure Period, press the Hz/P key twice. Hz (S) FREQ (PERIOD) Indicates Frequency (period) measurement 2nd display shows the title 3. Connect the test lead and measure Connect the test lead between the V and the COM port. The display updates the reading. V COM Frequency range 10Hz ~ 800kHz Sensitivity 10Hz ~ 100kHz: >0.1V 100kHz ~ 600kHz: >1.0V 600kHz ~ 800kHz: >2.5V Period Range 1.25µs ~ 0.1s Sensitivity 1.25us ~ 1.666us: > 2.5V 1.666us ~ 10us: > 1.0V 10us ~ 0.1s: > 0.1V AC Current Frequency Input level Sensitivity level Sensitivity 10Hz~10kHz 10mA/100mA > 7mA rms 45Hz~10kHz 1A/10A > 3mA rms 36

37 BASIC MEASUREMENT Temperature Measurement Background 1. Activate temperature measurement The GDM-8200A series accepts thermocouple input and calculates the temperature from the voltage fluctuation. Thermocouple type and reference junction temperature are also being considered. For Celsius unit, press the C/ F key once. For Fahrenheit unit, press the C/ F key twice. 2. Temperature mode display appears C ( F) Indicates Temperature measurement TYPE J 2 nd display shows the thermocouple type 3. Connect the test lead and measure Connect the thermocouple lead between the V and the COM port. The display updates the reading. V Range 0 ~ +300 C COM 37

38 GDM-8200A Series User Manual Select thermocouple type Background The GDM-8200A series assumes that a certain type of thermocouple, which reads voltage fluctuation induced by temperature changes, is used to measure the temperature. Parameter Type Range Resolution K 0 ~ +300 C 0.01 C T 0 ~ +300 C 0.01 C J 0 ~ +300 C 0.01 C 1. Open sensor selection menu Press the Shift key, then the C/ F (Sensor) key. The sensor selection menu appears on the display. 2. Select sensor type Press the Right key to highlight the thermocouple type. Press the Up/Down key. The thermocouple type switches to the next one. 3. Confirm and go back to the default display Press the Enter key to confirm. Press the Exit key to go back to the default display. 38

39 BASIC MEASUREMENT Set reference junction temperature Background 1. Open reference junction menu When a thermocouple is connected to the GDM-8200A series, the temperature difference between the thermocouple lead and the the GDM-8200A series input terminal should be taken into account and be cancelled; otherwise an erroneous temperature might be added. Type Range Resolution SIM (simulated) 0 ~ +50 C 0.01 C The terminal temperature is manually defined by the user. Default value: Press the Shift key, the C/ F (Sensor) key, then the Down key. The reference junction selection menu appears on the display. 2. Edit reference temperature Use the Left/Right key to move the cursor, and use the Up/Down key to change the value. Default: Press the Enter key to confirm the value, or the Exit key to cancel. The display goes back to the default state. (confirm) (cancel) 39

40 GDM-8200A Series User Manual ADVANCED MEASUREMENT Overview Advanced Measurement Overview Common attribute: refresh rate Common attribute: reading indicator Common attribute: manual/automatic triggering.. 42 dbm/db dbm/db Measurement Measure dbm Measure db Max/Min Max/Min Measurement Relative Relative Value Measurement Hold Hold Measurement Compare Compare Measurement Math Math Measurement Measure MX+B Measure 1/X Measure Percentage Dual Display Dual Display Measurement

41 ADVANCED MEASUREMENT Advanced Measurement Overview Background Advanced measurement mainly refers to the type of measurement which uses the result obtained by one of the basic measurements: ACV, DCV, ACI, DCI, 2/4W, Diode/Continuity, Frequency/Period, and Temperature. Advanced Measurement Basic Measurement AC/DCV AC/DCI 2/4W Hz/P C/ F db dbm Max/Min Relative Hold Compare Math Dual Measurement Common attribute: refresh rate Background Refresh rate defines how frequently the GDM-8200A series captures and updates the measurement data. Faster refresh rate yields lower accuracy and resolution. Slower refresh rate yields higher accuracy and resolution. Consider these trade-offs when selecting the refresh rate. Range S 5 ½ digits M 4 ½ digits F 3 ½ digits Selection step 1. Press the Shift key followed by the AUTO (RATE) key. The refresh rate switches to the next. 41

42 GDM-8200A Series User Manual 2. The refresh rate indicator shows the current status. Common attribute: reading indicator Background The reading indicator next to the 1st display flashes according to the refresh rate when the captured data is updated on the display. When no data is captured When there is no captured data, the reading indicator flashes once per two seconds (slower than the normal refresh rate), showing the GDM-8200A series is in the waiting mode. Common attribute: manual/automatic triggering Automatic triggering (default) Manual triggering The GDM-8200A series triggers according to the refresh rate. See the previous page for refresh rate setting details. Press the TRIG key to trigger measurement manually. 42

43 ADVANCED MEASUREMENT dbm/db Measurement Applicable to Background (NOT applicable to ACV+DCV) Using the ACV or DCV measurement result, the GDM-8200A series calculates the db or dbm value based on a reference resistance value in the following way. dbm db 10 x log10 (1000 x Vreading 2 / Rref) dbm dbmref Parameters Vreading Input Voltage, ACV or DCV Measure dbm Vref Rref dbmref Reference voltage obtained by Rref/1mW Reference impedance simulating an output load Reference dbm value Activate dbm Press the Shift key followed by the / key. The 1st display shows dbm, and the 2nd display shows the reference impedance. dbm result appears dbm 600Ω Indicates dbm measurement 2nd display indicates the reference impedance Select reference impedance To change the reference impedance, press the Up/Down key. The new impedance appears in the 2nd display. The following is the impedance list

44 GDM-8200A Series User Manual Deactivate dbm measurement To cancel the dbm measurement, press the Shift key followed by the key, or simply activate another measurement. Measure db Background Activate db db is defined as [dbm dbmref]. When the db measurement is activated, the GDM-8200A series calculates the dbm using the reading at the first moment and stores it as dbmref. Press the Shift key followed by the Hz/P key. The 1st display shows db, and the 2nd display shows the current Voltage reading. db result appears db Indicates db measurement mV Indicates the present Voltage reading dbmref Deactivate db measurement Press the 2 ND key to see the dbmref value. To cancel the dbm measurement, press the Shift key followed by the Hz/P key, or simply activate another measurement. 44

45 ADVANCED MEASUREMENT Max/Min Measurement Applicable to Background 1. Activate Max/Min Maximum and Minimum measurement stores the highest (maximum) or lowest (minimum) reading and shows it on the 2nd display. For Max measurement, press the MX/MN key once. For Min measurement, press the MX/MN key twice. 2. Max (Min) result appears MIN (MAX) Indicates Min (Max) measurement nd display shows the Min (Max) measurement result Deactivate Max/Min measurement To cancel the Max/Min measurement, press the MX/MN key for 2 seconds, or simply activate another measurement. 45

46 GDM-8200A Series User Manual Relative Value Measurement Applicable to Background 1. Activate Relative measurement Relative measurement stores a value, typically the data at the moment, as the reference. The following measurement is shown as the delta between the reference. Press the REL key. The measurement reading at the moment becomes the reference value. 2. Relative measurement display appears REL Indicates Relative value measurement 2nd display Shows the reference value 1st display Shows the delta between the current measurement data and the reference value Manually set the reference value 1. To set the reference value manually, press the Shift key followed by the REL key. The setting appears. REL 1st display 2nd display Indicates Relative measurement Shows the reference value Indicates Relative value modification 2. Use the Left/Right key to move the flashing point (cursor), and use the Up/Down key to change the value. 46

47 ADVANCED MEASUREMENT 3. Press the Enter key to confirm the value, or the Exit key to cancel. The display switches to measurement. (confirm) (cancel) Deactivate Relative measurement To cancel the Relative measurement, press the Shift key followed by the REL key, or simply activate another measurement. 47

48 GDM-8200A Series User Manual Hold Measurement Applicable to Background 1. Activate Hold measurement Hold measurement retains the current measurement data and updates it only when the reading fluctuates more than the threshold setting as the percentage of the retained data. Press the HOLD key. 2. Hold measurement display appears HOLD Indicates Hold measurement 2nd display Shows the Hold threshold 1st display The measurement data which is updated only when it fluctuates more than the threshold compared to the retained value. 3. Select hold threshold Deactivate Hold measurement Select the hold threshold using the Up/Down key. The 2 nd display changes accordingly. Range 0 ~ 99%, 1% resolution To cancel the Hold measurement, press the Hold key for 2 seconds, or simply activate another measurement. 48

49 ADVANCED MEASUREMENT Compare Measurement Applicable to Background 1. Activate Compare measurement Compare measurement checks and updates if the measurement data stays between the upper (high) and lower (low) limit specified. Press the Shift key, then the HOLD (Comp) key. 2. High limit setting 1st display Shows the high limit value 2nd display Indicates high limit setting 1. Use the Left/Right key to move the cursor (flashing point) between high/low setting, digits, and decimal point. 2. Change the parameter using the Up/Down key. 3. Press the ENTER key to confirm editing and move to the low limit setting. 49

50 GDM-8200A Series User Manual 3. Low limit setting 1st display 2nd display Shows the low limit value Indicates low limit setting 1. Use the Left/Right key to move the cursor (flashing point) between high/low setting, digits, and decimal point. 2. Change the parameter using the Up/Down key. 3. Press the ENTER key to confirm editing. The compare measurement starts right away. 4. Compare measurement appears COMP Indicates Compare mode 2 nd display Shows the compare measurement result: Pass, High, or Low. 50

51 ADVANCED MEASUREMENT 5. Result High If the 2 nd display shows High, the result is above the High limit. Digital I/O: FAIL Out (Pin 6) and HIGH Limit FAIL Out (Pin 7) are activated. Low Pass If the 2 nd display shows Low, the result is below the Low limit. Digital I/O: FAIL Out (Pin 6) and LOW Limit FAIL Out (Pin 8) are activated. If the 2 nd display shows Pass, the result is staying between the High and the Low limit. Digital I/O: PASS Out (Pin 5) is activated. Digital I/O The Compare measurement result comes out from the rear panel Digital I/O terminal. For the terminal details, see page89. Deactivate Compare measurement To cancel the Compare measurement, press the Shift key followed by the HOLD (Comp) key, or simply activate another measurement. 51

52 GDM-8200A Series User Manual Math Measurement Applicable to Background Math measurement runs three types of mathematical operation, MX+B, 1/X, and percentage, based on the other measurement results. Math type MX+B Multiplies the reading (X) by the factor (M) and adds/subtracts offset (B). 1/X Divides the reading (X) by 1, which provides the inverse number. Percentage Runs the following equation. (ReadingX Reference) Reference x 100% Measure MX+B 1. Activate MX+B Press the Shift key followed by the 2/4W (Math) key. The MX+B setting appears. 2. Set the factor (M) 1st display Shows the factor (M) 2nd display Indicates MX+B (The letter M flashes) 1. Use the Left/Right key to move the cursor (flashing point) between the factor, digits, and decimal point. 52

53 ADVANCED MEASUREMENT 2. Change the parameter using the Up/Down key. 3. Press the ENTER key to confirm editing and move to offset setting. 3. Set the offset (B) 1st display Shows the offset (B) 2nd display Indicates MX+B (The letter B flashes) 1. Use the Left/Right key to move the cursor (flashing point) between the offset, digits, and decimal point. 2. Change the parameter using the Up/Down key. 4. View MX+B 3. Press the ENTER key to confirm the editing. The MX+B measurement result appears. 1st display Shows the calculated result 2nd display Indicates MX+B MATH Indicates Math operation 53

54 GDM-8200A Series User Manual Measure 1/X 1. Activate 1/X Press the Shift key, the 2/4W (Math) key, the Down key twice. The 1/X setting appears. Press the ENTER key to view the 1/X measurement result. Measure Percentage 1st display Shows the 1/X value 2nd display Indicates 1/X MATH Indicates Math operation 1. Activate Percentage Press the Shift key, the 2/4W (Math) key, the Up key. The Reference setting appears. The Percentage is calculated as: [Reading Reference]/Reference x 100%. 2. Set the reference number 1st display Shows the reference number 2nd display Indicates Percentage setting 54

55 ADVANCED MEASUREMENT 1. Use the Left/Right key to move the cursor (flashing point) between high/low setting, digits, and decimal point. 2. Change the parameter using the Up/Down key. 4. View Percentage 3. Press the ENTER key to confirm editing and move to offset setting. 1st display Shows the calculated result 2nd display Indicates the Percentage measurement MATH Indicates Math operation Dual Display Measurement Background You can use the 2nd display to show another item, thus viewing two different measurement results at once. The following table shows the available options. 1 st Display 2 nd Display ACV DCV ACI DCI Hz/P ACV DCV ACV+DCV ACI DCI ACI+DCI 55

56 GDM-8200A Series User Manual 2W* (see Note) Hz/P C/ F / Note In the dual display mode, the resistance needs to be larger than 1MΩ. Some combination of dual display mode is possible but may not be useful, and their accuracies are not guaranteed. 2 nd Measurement item setting Press the 2nd key, then the target item (example: ACV). The display updates the measurement result. (example: ACI + ACV) 1 st Display Shows the primary measurement result 2 nd Display Shows the secondary measurement result 2ND Indicates that dual measurement is active Turn Off 2 nd Measurement To turn Off the 2 nd measurement, press and hold the 2 nd key for more than 1 second. 56

57 SYSTEM/DISPLAY CONFIGURATION SYSTEM/DISPLAY CONFIGURATION Refresh Rate Trigger Refresh Rate Setting...58 Manual/Automatic triggering...59 Use external trigger...59 Set trigger delay...60 Digital Filter Overview...62 Filter setting...63 Display Display Setting...64 Display on/off setting (+ key lock)

58 GDM-8200A Series User Manual Refresh Rate Setting Background Refresh rate defines how frequently the GDM-8200A series captures and updates the measurement data. Faster refresh rate yields lower accuracy and resolution. Slower refresh rate yields higher accuracy and resolution. Consider the trade-off when selecting the refresh rate. Display/Range S M F 5 ½ digits 4 ½ digits 3 ½ digits Refresh rate selection Press the Shift key followed by the AUTO key. The refresh rate indicator switches to the next. 58

59 SYSTEM/DISPLAY CONFIGURATION Trigger Setting Manual/Automatic triggering Automatic triggering (default) Manual triggering The GDM-8200A series triggers according to the refresh rate. See the previous page for refresh rate setting details. Press the TRIG key to trigger measurement manually. Use external trigger Background Signal connection The GDM-8200A series uses the internal trigger by default, for example to count the frequency and the period. Using an external trigger allows customized triggering condition. Connect the external trigger signal to the Digital I/O port located on the rear panel. DB-9, female Digital I/O pin assignment HIGH Limit FAIL Out FAIL Out LOW Limit FAIL Out EOM Out VCC Out PASS Out NC External Trigger In Digital (Chassis) Ground 59

60 GDM-8200A Series User Manual 1. Activate external trigger Press the Shift key followed by the TRIG key. The EXT indicator appears on the display. 2. Start trigger Press the TRIG key to start triggering manually. The indicator turns On. Reading indicator The reading indicator stays On before triggering. After triggering, the indicator flashes according to the external signal trigger timing. Exit external trigger Press the Shift key followed by the TRIG key. The EXT indicator disappears and the trigger goes back to internal mode. Set trigger delay Background Panel operation Trigger delay defines the time rag between triggering and measurement start. The default is set at 10ms. 1. Press the Shift key, the 2ND (Menu) key, the Right key, the Down key. The delay menu appears. 2. Press the Down key. The delay setting appears. 60

61 SYSTEM/DISPLAY CONFIGURATION 3. Move the flashing point (cursor) using the Left/Right key. Change the value using the Up/Down key. 4. Press the ENTER key to confirm editing and press the EXIT key. The display goes back to previous mode. Range 1 ~ 1000ms, 1ms resolution 61

62 GDM-8200A Series User Manual Digital Filter Setting Overview Filter basic Filter type The GDM-8200A series internal digital filter converts the analog input signal into digital format before passing it to internal circuits for processing. The filter affects the amount of noise included in the measurement result. The digital filter averages a specific number of input signal samples to generate one reading. The filter type defines the averaging method. The following diagrams show the filter difference as an example of averaging 4 samples per reading. Moving (default) Moving filter takes in one new sample and discards the oldest sample per reading. This is the default behavior when the digital filter is not specified, and is recommended for most applications except for the optional scanner operation (page71). 3rd reading Sample 3-6 2nd reading Sample 2-5 1st reading Sample 1-4 Sample # Repeating Repeating filter renews the whole samples per reading. This method is recommended when using the optional scanner (page71). 1st reading Sample 1-4 2nd reading Sample 5-8 3rd reading Sample 9-12 Sample # Filter count Filter count defines the number of samples to be averaged per reading. More samples offer low noise but long delay. Less samples offer high noise but short delay. Range 2 ~

63 SYSTEM/DISPLAY CONFIGURATION Filter setting Step 1. Press the Shift key followed by the MX/MN (Filter) key. 1st display Shows the filter count 2nd display Shows the filter type (flashing) 2. Select the filter type using the Up/Down key. 3. Move the cursor to filter count using the Left/Right key. Change the value using the Up/Down key. 4. Press the ENTER key to confirm editing. The Filter indicator appears on the display. FILT Indicates manual Filter setting 63

64 GDM-8200A Series User Manual Display Setting Display light setting Background Panel operation Display light setting adjusts the brightness of the display reading. Use level 3 or more (brighter) when working indoor; use level 2 or 1 (darker) when working outdoor under the sun. Level 5 (brightest) ~ 1 (darkest), default Level 3 1. Press the Shift key followed by the 2ND (Menu) key. The system menu appears. 2. Press the Down key, then the Right key twice. The light menu appears. 3. Press the Down key. The light level setting appears. 1st display Shows the current display light level 4. Select the level using the Up/Down key. 5. Press the Enter key to confirm your selection. Press the Exit key to go back to the default display. 64

65 Display on/off setting (+ key lock) SYSTEM/DISPLAY CONFIGURATION Background Panel operation The display can be turned off when not used for a long time. Note that when this function is used, the panel keys are also locked except for the Output On/Off key. The display is turned on by default. 1. Press the Output On/Off key once. The display will be turned off and the panel keys become locked. 2. To enable the display and panel keys, press the Output On/Off key again. 65

66 GDM-8200A Series User Manual STORE/RECALL For storing and recalling measurement results using the Scanner, see page71. Store Measurement Record Recall Measurement Record Save Instrument Settings Recall Instrument Settings

67 STORE/RECALL Store Measurement Record Background The GDM-8200A series can store the measurement history which can be recalled later for observation and analysis as in Maximum, Minimum, and Average value. Data count 1 ~ 9999 Not applicable to Store/recall measurement history is not applicable to Diode/Continuity test /. Store step 1. Press the Shift key followed by the DCI (Store) key. The store menu appears. 2. Move the cursor using the Left/Right key. Change the data count using the Up/Down key. 3. Press the Enter key to confirm editing and to go back to the previous display. STO Indicates the measurement history is stored 67

68 GDM-8200A Series User Manual Recall Measurement Record Background The GDM-8200A series can recall the stored measurement history for observation and analysis as in Maximum, Minimum, and Average value. Not applicable to Store/recall measurement history is not applicable to Diode/Continuity test. Recall stored record Press the Shift key, then the ACI (Recall) key. The stored measurement record appears. 1st display 2nd display RCL Shows the stored measurement result Shows the reading count Indicates the data has been recalled View each reading View Max/Min/ Average Change the reading count using the Up/Down key. Switch to the Average/Maximum/ Minimum value of the recorded data using the Right key. 68

69 STORE/RECALL Save Instrument Settings Background Set Instrument Setting The GDM-8200A series can save up to ten instrument settings. The settings can save the state, function, I/O and range. Upon powering up, the current instrument setting is displayed. Press the Shift key, the 2ND key, Down and then Left twice. The Save menu appears. Press the Down key to enter the Save menu. Memory Slot Selection Confirm Selection Choose the memory slot to save to by using the Up, Down, Left and Right keys. Press Enter to confirm the save slot. Press the Shift key to return to the measurement screen. The current instrument settings have been saved. To enable the settings at power up, follow the instructions in the next section. 69

70 GDM-8200A Series User Manual Recall Instrument Settings Background Set Instrument Setting The Recall function to enables saved settings to be recalled power up. Press the Shift key, then the 2ND (Menu) key, Down and Left once. The Recall menu appears. Press the Down key to enter the Recall menu. Memory Slot Selection Confirm Selection Choose the memory slot to recall from by using the Up, Down, Left and Right keys. Press Enter to confirm the memory slot. Press the Shift key to return to the measurement screen When the instrument is reset or upon the next power up, the recalled settings will be enabled. 70

71 SCANNER (OPTIONAL) SCANNER (OPTIONAL) The optional scanner GDM-SC1 lets you effectively measure multiple channels connected to a single the GDM-8200A series. Installation GDM-SC1 Scanner Specifications...72 Configure scanner...72 Select Channel group and enable scanner...74 Connect wire...75 Insert scanner...76 Scanner Configuration Record...78 Setup Overview...79 Setup Simple Scan...80 Setup Advanced Scan Use external trigger...84 Run Overview...86 Run Scan/Step...86 Recall Scan/Step result...87 Setup and run monitoring

72 GDM-8200A Series User Manual GDM-SC1 Scanner Specifications 2-wire channel 16 pairs Maximum current 2A (ch17, ch18) 4-wire channel 8 pairs Resistance 2/4 wire Single wire channel N/A Cold junction N/A (internal) Maximum voltage 250V Connection Screw terminal Scanner Installation Configure scanner Open Scanner cover 1. Take off four screws from the bottom panel of the scanner. 2. Remove the top panel. 72

73 SCANNER (OPTIONAL) 3. The connection terminals appear. Overview Scan/Step connection 16 general purpose channels are available, 8 on the left row, 8 on the right row. Current (ACI, DCI) measurement uses 2 extra channels. All channels are fully isolated (Hi and Lo). Refer to the below table for measurement and test line connection. Item No. of wire No. of channels DCV, ACV 2 wires (H, L) 16 (CH1 ~ 16) DCI, ACI 2 wires (H, L) 2 (CH17, 18) 2W Resistance 2 wires (H, L) 16 (CH1 ~ 16) 4W Resistance 4 wires (Input H, L + Sense H, L) 8 pairs (CH1 [input]& 9[sense], 2&10,...8&16) Diode/Continuity 2 wires (H, L) 16 (CH1 ~ 16) Period/Frequency 2 wires (H, L) 16 (CH1 ~ 16) Temperature 2 wires (H, L) 16 (CH1 ~ 16) 73

74 3 21 GDM-8200A Series User Manual Select Channel group and enable scanner Background 2 groups, 16 channels each, are available for the scanner. Group1 CH101 ~ 118 Group2 CH201 ~ 218 Select group (Jumper J8) Set the jumper J8 in the center of the board accordingly. Move the jumper to the right (pins 2-3) for selecting CH1xx (101 ~ 118), and move to the left (pins 1-2) for selecting CH2xx (201 ~ 218). CH SLAVE 1 23 J CH MASTER J Enable scanner (Jumper J9) Set the jumper J9 on the rear side of the board accordingly. Move the jumper up (pins 3-2) to disable the scanner, and down (pins 2-1) to enable the scanner. Disabled J J9 Enabled 74

Digital Multimeter. GDM-8200A Series USER MANUAL. 99 Washington Street Melrose, MA Phone Toll Free

Digital Multimeter. GDM-8200A Series USER MANUAL. 99 Washington Street Melrose, MA Phone Toll Free 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digital Multimeter Back to the Instek GDM-8251A/55A Page GDM-8200A Series USER

More information

Dual Measurement Multimeter

Dual Measurement Multimeter Dual Measurement Multimeter GDM-8261 USER MANUAL GW INSTEK PART NO. 82DM-82610EA1 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyrights. All rights

More information

Dual Measurement Multimeter

Dual Measurement Multimeter Dual Measurement Multimeter GDM-8261A USER MANUAL GW INSTEK PART NO. 82DM-8261AEF1 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyrights. All rights

More information

Electrical Safety Tester

Electrical Safety Tester Electrical Safety Tester GPT-9600 Series QUICK START GUIDE GW INSTEK PART NO. 82PT-96030MA1 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright.

More information

Electrical Safety Tester

Electrical Safety Tester Electrical Safety Tester GPT-9000 Series QUICK START GUIDE GW INSTEK PART NO. 82PT-90000MA1 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright.

More information

Arbitrary Function Generator

Arbitrary Function Generator Arbitrary Function Generator AFG-2000 Series USER MANUAL GW INSTEK PART NO. 82AF-21200ED1 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright.

More information

Arbitrary Function Generator

Arbitrary Function Generator Arbitrary Function Generator AFG-2000 Series USER MANUAL GW INSTEK PART NO. 82AF-21200EB1 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright.

More information

Dual Display Digital Multimeter

Dual Display Digital Multimeter Dual Display Digital Multimeter GDM-8246 GW INSTEK PART NO. 82DM-82460MG1 This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual

More information

50000 Counts Dual Display Digital Multimeter

50000 Counts Dual Display Digital Multimeter 50000 Counts Dual Display Digital Multimeter GDM-8245 (50000 Counts) The GDM-8245 is an economical bench-top DMM equipped with a rich set of features. The GDM-8245 has similar functions to the GDM-8246,

More information

Multi-output DC Power Supply

Multi-output DC Power Supply Multi-output DC Power Supply GPE-1326/2323/3323/4323 Series USER MANUAL GW INSTEK PART NO. 82GP343230E01 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected

More information

Synthesized Function Generator

Synthesized Function Generator Synthesized Function Generator SFG-1000 Series USER MANUAL GW INSTEK PART NO. xxxxxxxxxxx This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part

More information

Arbitrary Function Generator

Arbitrary Function Generator Arbitrary Function Generator AFG-2000 Series QUICK START GUIDE GW INSTEK PART NO. 82AF-21200M01 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright.

More information

Multiplex Scanner Box

Multiplex Scanner Box Multiplex Scanner Box GSB-01/GSB-02 USER MANUAL GW INSTEK PART NO. 82SB-02000EA1 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights

More information

EC Declaration of Conformity

EC Declaration of Conformity EC Declaration of Conformity TABLE OF CONTENTS 1. SAFETY SUMMARY.. 1 2. INTRODUCTION 5 3. SPECIFICATION 7 EN 61326-1: Electrical equipment for measurement, control and laboratory use EMC requirements (1997+A1:

More information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate

More information

COM-POWER OPERATION MANUAL ACS W

COM-POWER OPERATION MANUAL ACS W COM-POWER OPERATION MANUAL For the ACS-250-100W 150 khz to 250 MHz 100W Power Amplifier Page 1 of 15 MANUAL_ACS-250-100W Rev. M02.15 Table of Contents Important Safety Precautions.....3 Introduction..5

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

SDM3045X Digital Multimeter. DataSheet

SDM3045X Digital Multimeter. DataSheet SDM3045X Digital Multimeter DataSheet-2016.06 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for

More information

Electrical Safety Tester

Electrical Safety Tester 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Electrical Safety Tester GPT-9600 Series USER MANUAL GW INSTEK PART NO. 82PT-96030EA1

More information

4 ½ Digit and 50,000 Count Bench Multimeters USER MANUAL

4 ½ Digit and 50,000 Count Bench Multimeters USER MANUAL Model 2831E, 5491B 4 ½ Digit and 50,000 Count Bench Multimeters USER MANUAL Notice The information contained in this document is subject to change without notice. Safety Notice Supplement As described

More information

30MHz Dual Trace Oscilloscope

30MHz Dual Trace Oscilloscope 30MHz Dual Trace Oscilloscope Model 72-6802 USER MANUAL This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual may be photocopied,

More information

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D 1. Safety Information Warning Use caution and follow all safety guidelines to prevent electric shock or damage to the meter. Please ready carefully

More information

Pocket Size Digital Multimeter with USB Model: A & A

Pocket Size Digital Multimeter with USB Model: A & A Pocket Size Digital Multimeter with USB Model: 72-7730A & 72-7732A 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is

More information

400Amp True RMS AC/DC Clamp Meter Model EX613

400Amp True RMS AC/DC Clamp Meter Model EX613 User's Guide 400Amp True RMS AC/DC Clamp Meter Model EX613 Introduction Congratulations on your purchase of this Extech EX613 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage,

More information

OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL OPERATOR S INSTRUCTION MANUAL AUTO-RANGE DUAL DISPLAY CONFORMED IEC1010 DIGITAL MULTIMETER CONTENTS PAGE SAFETY INFORMATION..... DESCRIPTION.. OPERATING INSTRUCTION.. SPECIFICATIONS.... ACCESSORIES. BATTERY

More information

312, 316, 318. Clamp Meter. Users Manual

312, 316, 318. Clamp Meter. Users Manual 312, 316, 318 Clamp Meter Users Manual PN 1989445 July 2002 Rev.2, 2/06 2002, 2006 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.

More information

True RMS Digital Multimeter Model:

True RMS Digital Multimeter Model: True RMS Digital Multimeter Model: 72-7780 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

User Manual. All rights reserved. Specifications are subject to change without notice.

User Manual. All rights reserved. Specifications are subject to change without notice. User Manual All rights reserved. Specifications are subject to change without notice. LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty

More information

Digital Clamp Meter Model: &

Digital Clamp Meter Model: & Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

5 ½ Bench Digital Multimeter

5 ½ Bench Digital Multimeter Model: 5492B, 5492BGPIB 5 ½ Bench Digital Multimeter USER MANUAL Safety Notice As described in the International Electrotechnical Commission (IEC) Standard IEC 664, digital multimeter measuring circuits

More information

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master Measurement Guide Power Meter for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master Power Meter Option 29 High Accuracy Power Meter Option 19 Inline Peak

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

Operating manual PREMIER Serie - English SEFELEC REFERENCE PENT4252

Operating manual PREMIER Serie - English SEFELEC REFERENCE PENT4252 Operating manual PREMIER Serie - English SEFELEC REFERENCE PENT4252 This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be

More information

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

RS Pro DIGITAL MULTI-METER SDM3055 SERIES ENGLISH Product Datasheet Stock No: 1236465 1236466 RS Pro DIGITAL MULTI-METER SDM3055 SERIES Product Overview RSDM3055 is a digital multimeter designed with 5 ½ digits readings resolution and dual-display,

More information

Model: &

Model: & 600A True RMS Digital Clamp Meter Model: 72-3097 & 72-3099 1 CONTENTS Page Number Details 3 Important Safety Information 4 Product overview 4 Key Functions 5 General Specification 5 Electrical Specification

More information

SAFETY PRECAUTIONS: Before use, read the following safety precautions

SAFETY PRECAUTIONS: Before use, read the following safety precautions [1] SAFETY PRECAUTIONS: Before use, read the following safety precautions This instruction manual explains how to use your multimeter CD731, CD751 safely. Before use, please read this manual thoroughly.

More information

KMD-S04 Multímetro de bolsillo

KMD-S04 Multímetro de bolsillo www.grupotemper.com KMD-S04 Multímetro de bolsillo Table of Contents Title Page Overview ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 3 Unpacking Inspection ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 Safety Information

More information

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at ASTROAI USER MANUAL DT132A 4000 Count Auto-Ranging Multimeter Thank you for purchasing the AstroAI DT132A 4000 Count Auto-Ranging Multimeter. It is a 3 ¾ digit, 3999 counts, auto-ranging digital multimeter.

More information

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information

ProfiScale MULTI Multimeter

ProfiScale MULTI Multimeter 1,5 V 9V 200 mv 600 V 200 ma 1/10 A ProfiScale MULTI Multimeter en Operating instructions BURG-WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany Introduction Want the reassurance of knowing whether current

More information

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is a high-accuracy,

More information

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide Agilent U1273A/U1273AX Handheld Digital Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads One pair of 4

More information

DIGITAL HiTESTER. Instruction Manual

DIGITAL HiTESTER. Instruction Manual 3801-0 DIGITAL HiTESTER Instruction Manual i Contents Contents Introduction...1 Verifying Package Contents...1 Safety Information... Operating Precautions... 1 Overview 7 1.1 Product Overview...7 1. Features...8

More information

INSTRUCTION MANUAL DIGITAL MULTIMETER

INSTRUCTION MANUAL DIGITAL MULTIMETER INSTRUCTION MANUAL DIGITAL MULTIMETER 600 OFF 600 20 2m 2 20m m m 2M 10A k 20k 2k O C NPN PNP hfe E B C E 10A DC 10A MAX UNFUSED MAX 600V COM V ma ma MAX FUSED CAT II 600V Thanks for buying our products,

More information

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. SAFETY INFORMATION... 1 2. TECHNICAL SPECIFICATIONS... 2 3. PARTS & CONTROLS...

More information

MS2109A AC/DC Clamp Meter. User Manual. Contents

MS2109A AC/DC Clamp Meter. User Manual. Contents MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

DVM1190 DIGITAL MULTIMETER

DVM1190 DIGITAL MULTIMETER DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps

More information

NOTE: Fully read and understand this manual before using this Digital Multimeter.

NOTE: Fully read and understand this manual before using this Digital Multimeter. ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and

More information

200Amp AC Clamp Meter + NCV Model MA250

200Amp AC Clamp Meter + NCV Model MA250 User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,

More information

Agilent U1271A/U1272A Handheld Digital Multimeter. Quick Start Guide

Agilent U1271A/U1272A Handheld Digital Multimeter. Quick Start Guide Agilent U1271A/U1272A Handheld Digital Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads One pair of 4 mm

More information

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS CONTENTS CONTENTS CONTENTS 1. SAFETY INFORMATION...1 1.1 Preliminary...1 1.2 Dos and don ts...2 1.3 Symbols...3 1.4 Precautions...4 2. DESCRIPTION...5 2.1 Names of parts...6 2.2 Switches, buttons and input

More information

SDM3045X Digital Multimeter. DataSheet

SDM3045X Digital Multimeter. DataSheet SDM3045X Digital Multimeter DataSheet-2018.12 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for

More information

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2. Contents 1. General instructions. 1.1 Precautions safety measures... 1.2 Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.2 LCD Display 2.3 Keypad. 3. Function description. 3.1

More information

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions RIGOL Data Sheet Product Overview DM3058/DM3058E [1] is a digital multimeter designed with 5 ½ digits readings resolution and dual-display especially fitting to the needs of high-precision, multifunction

More information

UT207A/208A/209A Operating Manual. Table of Contents

UT207A/208A/209A Operating Manual. Table of Contents Table of Contents Title Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Display Symbols Functional Buttons The Effectiveness

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

Mini Clamp Meter Model:

Mini Clamp Meter Model: Mini Clamp Meter Model: 72-2985 1 CONTENTS Page Number Details 2 What s Included 3 Important Safety Information 3 Technical Specification 4 Product Overview 5 LCD Overview 6 Operation - AC/DC Voltage Measurement

More information

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &

More information

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 www.keithley.com Model 2010 Low-Noise Multimeter Specifications DC CHARACTERISTICS CONDITIONS: MED (1 PLC) 1 or SLOW (5 PLC)

More information

True RMS Bench Multimeter 5492B

True RMS Bench Multimeter 5492B Data Sheet True RMS Bench Multimeter 5492B True RMS Bench Multimeter The B&K Precision model 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service

More information

MW3105 DIGITAL CLAMP MULTIMETER

MW3105 DIGITAL CLAMP MULTIMETER MW3105 DIGITAL CLAMP MULTIMETER 2 M MW3105 A 01 INTRODUCTION 1.1 - Unpacking and inspection Upon removing your new Digital Clamp Meter from its packing, you should have the following items: 1. Digital

More information

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX 756 & 7562 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is

More information

IDM 503 & 505 Digital Multimeters

IDM 503 & 505 Digital Multimeters Instruction Manual IDM 503 & 505 Digital Multimeters IDM 505 SECTION 1 SAFETY INFORMATION Safety Information Understand and follow operating instructions carefully. Use the Instrument only as specified

More information

RIGOL. Quick Guide. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Jul RIGOL Technologies, Inc.

RIGOL. Quick Guide. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Jul RIGOL Technologies, Inc. Quick Guide DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator Jul. 2012 RIGOL Technologies, Inc. Guaranty and Declaration RIGOL Copyright 2011 RIGOL Technologies, Inc. All Rights Reserved.

More information

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter User s Manual MiniTec TM Series Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter Introduction Congratulations on your purchase of Extech s MN26 Autoranging Multimeter. This

More information

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER User Manual Gebruikershandleiding Manuel d'utilisation Gebrauchsanleitung Introduction BENCH MULTIMETER This manual

More information

User Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. Digital AC/DC Clamp Meter Model 38394 User Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,

More information

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of

More information

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM DATA SHEET 34450A Multimeter 5.5 Digit Dual Display, Benchtop DMM Features Fast reading speed of up to 190 readings/sec 0.015% DCV accuracy Multiple connectivity options USB 2.0, Serial Interface (RS-232)

More information

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter DL6508 User's Guide 1500Amp True RMS AC/DC Clamp Meter Introduction Congratulations on your purchase of this DL6508 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage, Resistance,

More information

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D Introduction MS8250D is a stable, safe, reliable compact digital handheld 6600 count, True RMS, auto-ranging multimeter. This meter can measure AC/DC

More information

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function Datasheet SDM3065X Digital Multimeter Product Overview SDM3065X is a 6 ½ digit digital (2,200,000 count) multimeter incorporating a dual display and is especially well suited for the needs of high-precision,

More information

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ)

More information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging

More information

True RMS Bench Multimeters 2831E and 5491B

True RMS Bench Multimeters 2831E and 5491B Data Sheet True RMS Bench Multimeters and True RMS Bench Multimeters with Dual Display The B&K Precision models and are versatile and dependable bench multimeters suitable for applications in education,

More information

Handheld Digital Multimeter

Handheld Digital Multimeter Handheld Digital Multimeter GDM-397, GDM-461 USER MANUAL GW INSTEK PART NO. 82DM-46100M01 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright.

More information

Digital MultiMeter - Make your job efficiency User Instruction Manual

Digital MultiMeter - Make your job efficiency User Instruction Manual Digital MultiMeter - Make your job efficiency User Instruction Manual Main Fields of Application: Process industries, Metallurgy, Power generation, Research, Laboratories, Maintenance, After sales service,

More information

1-1 Introducing the 50,000 Count Dual Display Multimeter

1-1 Introducing the 50,000 Count Dual Display Multimeter Section 1 Introduction 1-1 Introducing the 50,000 Count Dual Display Multimeter NOTE 1. This operation manual contains information and warning that must be followed to ensure user operation safety and

More information

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...

More information

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use http://www.all-sun.com EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL V Read this owners manual thoroughly before use WARRANTY This instrument is warranted to be free from defects in material and workmanship

More information

User s Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394 User s Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,

More information

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS CONTENTS MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 2 1.2 DURING USE 3 1.3 SYMBOLS 5 1.4 MAINTENANCE 6 2. DESCRIPTION 8 2.1 NAMES OF COMPONENTS 9

More information

ATK Clamp Meter

ATK Clamp Meter ATK-2209 Clamp Meter User s Manual Title CONTENTS Page I. SAFETY INFORMATION... 1 II. TECHNICAL SPECIFICATIONS... 2 2-1 Environment Conditions... 2 2-2 Maintenance... 2 2-3 Features... 2 2-4 General Specifications...

More information

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM USER MANUAL Model MA440 400A AC Clamp Meter DMM Model MA443 True RMS 400 AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM Introduction Thank you for selecting the Extech EX44x Series

More information

Model 77 Series IV. Digital Multimeter. Users Manual

Model 77 Series IV. Digital Multimeter. Users Manual Model 77 Series IV Digital Multimeter Users Manual Model 77 Series IV Digital Multimeter The Fluke Model 77 Series IV is a battery-powered, average responding-rms indicating multimeter (hereafter "the

More information

RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc.

RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc. Quick Guide DG2000 Series Function/Arbitrary Waveform Generator Sept. 2010 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information

More information

400Amp True RMS AC Clamp Meter + NCV

400Amp True RMS AC Clamp Meter + NCV User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet DC CHARACTERISTICS [1] ACCURACY ± (% of reading + % of range) Temperature Cefficient

More information

Tablet Oscilloscope Safety Information

Tablet Oscilloscope Safety Information Tablet Oscilloscope Safety Information Shenzhen Micsig Instruments Co., Ltd. General Safety Summary To use the instrument safely, please follow safety precautions carefully and obey the well-known safety

More information

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature USER GUIDE True RMS Digital Multimeters EX350 Series EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature Table of Contents 1. INTRODUCTION 3 2. SAFETY INFORMATION 4 3.

More information

Signal and Tracking Generator

Signal and Tracking Generator Signal and Tracking Generator USG Series USER MANUAL REVISION 1.1 January 2014 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

More information

MS8223A. CAT.IIi 600 V

MS8223A. CAT.IIi 600 V Pen-type Digital Multimeter Manual MS8223A CAT.IIi 600 V CONTENTS 1. Safety Information......1 1.1 Preparing for use...1 1.2 During Use......2 1.3 Safety Symbols...3 1.4 Maintenance...4 2. Description......4

More information

OPERATION MANUAL TH1942

OPERATION MANUAL TH1942 OPERATION MANUAL TH1942 50000 Count Multimeter Manual Printing History The manual printing data and part number indicate its current edition. The printing date changes when a new edition is printed. The

More information

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL Warnings and Safety symbols: Caution, refer to this manual before using the meter. Dangerous voltages. Meter is protected throughout by double insulation or

More information

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL Ω CONTENTS CONTENTS 1. SAFETY INFORM...1 4.4 Range Transform...10 1.1 Preliminary...1 4.5 Auto Power Off...10 1.2 During use...2 4.6 Preparation For Measurement...11

More information

The Meter Structure The Figure 2-1 shows the Meter structure.

The Meter Structure The Figure 2-1 shows the Meter structure. P/N:110401104496X The Meter Structure The Figure 2-1 shows the Meter structure. 1. USB Terminals 2. LCD Display 3. Functional Buttons 4. Rotary Switch 5. Power adaptor Input Terminals 6. 10A Input Terminal

More information