What is different? Between Impulse Noise and Electrical Fast Transient Burst

Size: px
Start display at page:

Download "What is different? Between Impulse Noise and Electrical Fast Transient Burst"

Transcription

1 What is different? Between Impulse Noise and Electrical Fast Transient Burst The Inquiry about "a distinction between an impulse noise simulator (following and our company model INS series) and a Fast transient Burst simulator (following and our company model FNS series)" is one of the major questions in a lot of quries from customers. Herewith the difference is focused and presented. The phenomenon which are reproduced and backgraound Both INS and FNS reproduce phenomenon of back electromotive energy noise which may be generated in ON/OFF of power supply switching (like a gas insulated braker and/or electromagnetism relay, etc.). INS was introduced by Mr. Manohar L.Tandor (at that time worked in I.B.M) as a simulator of the high frequency noise to data processing apparatus in the 1960s, and the computer maker of those days adopted it in the 1970s, and it spread widely. FNS is indicated as a basic standard of the immunity type test which reproduces the malfunction by the noise phenomenon of switching ON/OFF and adopted not only in Europe but also world-wide. The 1 st edition of Standard for this test was issued as IEC801-4 in IEC TC65 (Industrial Process Controls) in Then, in order to adopt to all the electric devices, IEC was issued in Moreover, in order to differenciate the numbering between ISO and IEC, has been added to the Stadanrd number. Consequently, it has been named as IEC output waveform Rise time / the pulse width [INS] It is a rectangular wave whose pulse width is 50ns-1μs and rise time is less than 1ns. <Entire waveform +2kV > <At rise up less than 1ns> 500V/ div 400ns/ div 500V/ div 1ns/ div 1

2 [FNS] It is a triangular wave whose pulse width is 50ns and rise time is 5ns.. <Entiire waveform +2kV > <At rise up less than 5ns> 500V/ div 40ns/ div 500V/ div 4ns/ div - Repetition intervals (Image and figure comparison) [INS] [FNS] *1 : 4kV type of INS is 16ms-999ms. *2 : Guaranteed accuracy is 5kHz khz (IEC standard requirement). Frequency characteristic [INS] Including broadband noise frequency more than 1GHz. 2

3 [FNS] The frequency components ceases below 400MHz. Output voltages [INS] Maximum voltage is available up to 4,000V. Although there is no specific provisions, the measure test voltage is basically 2,000V and it may be increased to 3,000V for taking some margin into the account. [FNS] Maximum voltage is available up to 4,800V. IEC Standard requires up to 4,000V.. Noise injection method [INS] To power lines : Normal mode (between a lines-line), and common mode (between a line - grounds) To signal lines : Magnetic field coupling and/or capacitive coupling which use clamps Featuring Normals mode injection taking power supply conditions in Japan into the account [FNS] To power lines :ONLY commonmode (between a line-ground To signal lines : Capacitive coupling which uses clamp Conforming Standards and Guide line [INS] NECA TR-28 (Nippon Electric Control Equipment Industries Association) JEM-TR177 (Japan Electrical Manufacturers' Association) JEC0103_2005 (Institute of Electrical Engineers) The individual industry and manufacturers private standards (Automobie, Consumer equipments, Industrial equipments, etc.) [FNS] IEC (International Electrotechnical Commission) JIS C (Japanese Industrial Standards Committee) The individual industry and manufactueres private standards (automobile etc.) 3

4 Conclusion Both the Impulse Noise test and Electrical Fast Transient Burst (EFT/B) test purpose withstand test for back electromotive energy noise which may be generated in ON/OFF of power supply switching. The repetition frequency of EFT/B tests is very fast, and it is broadly adopted based on provision of international standard IEC to world-wide including Japan as JIS C On the other hand, although the Impulse Noises tests are not requested In international standards, it is standardized in some Japanese authorized committees or associatons as it is descrived in the above for point of the view it enables to verify immunity quantitativeness against the noise in spreaded broad band range and such rectangular waved impulse noise immunity test which can compare with the actual recordd in the markets should be standardized. Therefore, the simulator has been popularly used by Japanese electrical manufacturers even they establish the factilites in overseas contries and carry on the test there. The rise time must be more rapid and frequency component lasts until higher range than EFT/B test and the tests both in normal mode and common mode can be done. Those can realize more severe tests than EFT/B test and tests in normal mode because of Japanese real power supply condtions. The reasons cause worth of the impulse noise tests in addition to EFT/B tests. Eventually, there are many Japanese manufacturers keep on doing both EFT/B and impulse noise tests in order to maintain and improve their products quality. [INS and a FNS comparative table] PARAMETER INS (IMPULSE NOISES) FNS(EFT/B NOISE) *3 Output waveform Rectangular (square) Triangular Rise times Less than 1ns 5ns The pulse width 50ns-1000ns 50ns Output voltages Max. 4000V Max. 4800V Repetition frequency Max 100Hz *4 Max 2MHz *5 Frequency components Including high frequency more than 1GHz 400MHz or less Test mode (To power lines) Common mode / Normal mode Only common mode Test mode (To signal lines) Capacitive coupling / magnetic field coupling Capacitive coupling Conforming Standard or Guildline NECA TR-28 JEM-TR177 JEC 0103_2005 Individual industry standards or private standards IEC JIS C Individual industry standards or private standards User Mainly Japanese Worldwide 4

5 * 3: EFT/B noise : Abbreviated name of Electrical Fast transients Burst noise * 4:100Hz is specification of the simulator whose output voltages is 2kV. (In case of 4kV output simulator, this parameter can be 60Hz) * 5: The requirement of the Standards is 100kHz. << Difference between old model and current model in Impluse Noise Simulator (INS series)>> Digitals controlling circuits are built in the current ones (The old ones are controlled with analog oscillation circuits) Therefore, there may be difficulty to take same tests results between the old ones and current ones due to slight dispersion of the noise generation timing, etc. even the rise up time of the waveforms and pulse durations are identical. It is recommended that scheming and devising problemless transfer from the old ones to the current ones with the simultaneous using for a while. 5

Fast Transient / Burst Simulator

Fast Transient / Burst Simulator EMC TESTS EQUIPMENTS CATALOGUE Fast Transient / Burst Simulator Reproduce showering arc at switching on/off of electric point of contact A simulator to reproduce fast repetitive frequency noises which

More information

Proposal of double voltage transmission line pulse generator using four coaxial cables

Proposal of double voltage transmission line pulse generator using four coaxial cables Proposal of double voltage transmission line pulse generator using four coaxial cables Hitoshi Kijima, Koji Ochi Abstract In order to carry out the simulation of an electrical noise, a pulse generator

More information

Immunity Testing for the CE Mark

Immunity Testing for the CE Mark Immunity Testing for the CE Mark Summary The European Union (EU) currently has 25 member countries with 2 additional countries to be added in 2007. The total population at that time will be nearly a half

More information

IEC Electrical fast transient / Burst immunity test

IEC Electrical fast transient / Burst immunity test CONDUCTED RF EQUIPMENT POWER AMPLIFIERS IEC 61000-4-4 Electrical fast transient / Burst immunity test IEC 61000-4-4 Electrical fast transient / Burst immunity test Markus Fuhrer Phenomenom open a contact

More information

CAR - TEST - SYSTEM 14

CAR - TEST - SYSTEM 14 CAR - TEST - SYSTEM 14 EMC-Test Equipment for electrical installation of vehicles Acc. to ISO 7637-2, ISO 16750-2 ISO 21848 Rise time variable 1-5µs Pulse Waveforms : #1 1-5/2000µs, 600 V, ISO 1-5/1000µs,

More information

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS TR550004 TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS TR NO. 174001 EDITION 2.1 September 3 rd, 2018 Nippon Telegraph and

More information

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment Christian Suttner*, Stefan Tenbohlen Institute of Power Transmission and High Voltage Technology (IEH), University of

More information

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi Features Special relay for alternating loads, for applications with pumps, compressors, air conditioning or refrigeration units 2 independent NO output, 12 A 4 functions 2 independent control signals,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61000-4-5 Second edition 2005-11 BASIC EMC PUBLICATION Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement techniques Surge immunity test This English-language

More information

C series Product brief

C series Product brief Product brief Key applications Landlord sub-metering Object metering Meter performance Direct connected up to 0 ctive energy Low power consumption larm function Pulse output Installation Small size - 1

More information

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC Product data sheet Characteristics RE11RMMU time delay relay 10 functions - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Width pitch dimension Control type Voltage range Connections

More information

SERIES K: PROTECTION AGAINST INTERFERENCE

SERIES K: PROTECTION AGAINST INTERFERENCE I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T K.132 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (01/2018) SERIES K: PROTECTION AGAINST INTERFERENCE Electromagnetic compatibility

More information

PART NUMBERING SYSTEM

PART NUMBERING SYSTEM Plug-In Timer 11 pins Multifunction or monofunction Compact body for space saving Wide time range (from 0.5 seconds to 10 days delay) Universal power supply (12-240 Vz) 1 or 2 relay outputs (SPDT / Changeover)

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay

More information

PART NUMBERING SYSTEM

PART NUMBERING SYSTEM Plug-In Timer pins Multifunction or monofunction Compact body for space saving Wide time range (from 0. seconds to 0 days delay) niversal power supply (-0 Vz) or relay outputs (SPDT / Changeover) Protective

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay

More information

Compliance to a standard or to the real world?

Compliance to a standard or to the real world? Compliance to a standard or to the real world? No one could have doubt as to the importance of the pulsed EMI test. In fact, in the scheme of international compliance, the Electrical Fast Transient/ Burst

More information

Fast transient burst simulator

Fast transient burst simulator Fast transient burst simulator FNS-AX4 series www.noiseken.com Fast transient / burst simulator FNS-AX4-A20/B63 Feature IEC 61000-4-4 Ed.3 standard compliance. Pre-check function is installed. Inspection

More information

z475 Remote DC Power Supply Preliminary

z475 Remote DC Power Supply Preliminary TECHNICAL SPECIFICATIONS z475 Remote DC Power Supply Preliminary 2018 LitePoint, A Teradyne Company. All rights reserved. Overview The z475 remote DC Power supply can provide a stable VCC voltage for PA/FEM/SW

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE (Main Laboratory) 5-1-1 Onna, Atsugi-shi, Kanagawa-ken, 243-0032 Japan (Commercial Office) 1-329 Kifune, Meito-ku Nagoya-shi,

More information

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent Technical Requirements for Resistibility of Telecommunications Equipment to Overvoltage and Overcurrent TR NO.189001 Edition 2.1 1st, April, 2015 Nippon Telegraph and Telephone Corporation Notice This

More information

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc. A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity

More information

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor. Introduction to EMC Schurter has over 75 years experience in the electronics and electrical industries, developing and manufacturing components that ensure a clean and safe supply of power. Schurter provides

More information

Advanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02.

Advanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02. Lightning Surge Simulator Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) LSS-F02 www.noiseken.com Conforming to IEC61000-4-5 ed2 Standard LSS-F02 series A simulator

More information

Specific Research Reports of the National Institute of Industrial Safety, NIIS-SRR-NO.26 (2002) UDC :

Specific Research Reports of the National Institute of Industrial Safety, NIIS-SRR-NO.26 (2002) UDC : Specific Research Reports of the National Institute of Industrial Safety, NIIS-SRR-NO.26 (2002) UDC 621.391.823:621.317.34 ** *** by Hajime TOMITA** and Toshiyuki UEKI*** Abstract: Electric and electronic

More information

Understanding Design, Installation, and Testing Methods That Promote Substation IED Resiliency for High-Altitude Electromagnetic Pulse Events

Understanding Design, Installation, and Testing Methods That Promote Substation IED Resiliency for High-Altitude Electromagnetic Pulse Events Understanding Design, Installation, and Testing Methods That Promote Substation IED Resiliency for High-Altitude Electromagnetic Pulse Events Tim Minteer, Travis Mooney, Sharla Artz, and David E. Whitehead

More information

LS200 TEST DATA IEC61000 SERIES

LS200 TEST DATA IEC61000 SERIES TEST DATA IEC61000 SERIES DWG. No. PA607-58-01 APPD CHK DWG TDK-Lambda INDEX LS200 PAGE 1. Electrostatic Discharge Immunity Test (IEC61000-4-2) R-1 2. Radiated Radio-Frequency Electromagnetic Field Immunity

More information

08/07/2015

08/07/2015 17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external

More information

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

Surge Generator for MIL-STD 1275

Surge Generator for MIL-STD 1275 Surge Generator for MIL-STD 1275 This generator PG1275 is specially designed for the test of the susceptibility to surges and spikes of military 28 Vdc electric circuits. The equipment allows performing

More information

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent Technical Requirements for Resistibility of Telecommunications Equipment to Overvoltage and Overcurrent TR NO.189001 Edition 3 1st, April, 2018 Nippon Telegraph and Telephone Corporation Notice This document

More information

OIML E 5 EXPERT REPORT. 6th Edition 2015 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

OIML E 5 EXPERT REPORT. 6th Edition 2015 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION EXPERT REPORT OIML E 5 6th Edition 2015 (E) Overview of the present status of the standards referred to in OIML D 11:2013 General requirements for measuring instruments Environmental conditions Revue du

More information

08/07/2015

08/07/2015 17.5 mm - 1 Relay 8A MUR1 Part number 88827105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external load connection

More information

For the National Voluntary Laboratory Accreditation Program

For the National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Intertek Japan K.K. Calibration Laboratory 3-2 Sunayama Kamisu Ibaraki 314-0255 JAPAN Ms. Masako Oyamada Phone: 81-465 89 2316 Fax: 81-465 89 2160 E-mail: masako.oyamada@intertek.com

More information

Center for Quality Engineering. Test Report No.: B0JA0002

Center for Quality Engineering. Test Report No.: B0JA0002 DAT-P-002/91-02 Center for Quality Engineering Test Report No.: Order No.: B0JA Pages: 10 Munich, Sep 12, 2008 Client: Infineon Technologies AG OP TTR RPT 2 Equipment Under Test: Manufacturer: Task: Test

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing Acoustic emission inspection Primary calibration of transducers

ISO INTERNATIONAL STANDARD. Non-destructive testing Acoustic emission inspection Primary calibration of transducers INTERNATIONAL STANDARD ISO 12713 First edition 1998-07-15 Non-destructive testing Acoustic emission inspection Primary calibration of transducers Essais non destructifs Contrôle par émission acoustique

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 75.00 USD Main Range of product Product

More information

Power Quality Issues from an EMC Point of View

Power Quality Issues from an EMC Point of View Power Quality Issues from an EMC Point of View Brian Jones BSc (Hons) C Eng MIEE MIEEE Overview What is EMC? How does it apply to power quality? The effects of equipment on power quality The effects of

More information

Overcurrent Protection / 7SJ45

Overcurrent Protection / 7SJ45 Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers

More information

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique Protection and control Sepam range Sepam 0 LA Self-powering protection Merlin Gerin Square D Telemecanique presentation contents page presentation protection functional and connection schemes other connection

More information

Scale Manufacturers Association (SMA) Recommendation on. Electrical Disturbance

Scale Manufacturers Association (SMA) Recommendation on. Electrical Disturbance Scale Manufacturers Association (SMA) Recommendation on Electrical Disturbance (SMA RED-0499) Provisional First Edition Approved by SMA Pending Final Comment April 24, 1999 Copyright: SMA, April, 1999

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O Product data sheet Characteristics RE22R2MMU Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output

More information

Cost effective method to locate the vulnerable nodes of circuits against the electrical fast transients

Cost effective method to locate the vulnerable nodes of circuits against the electrical fast transients Journal of Electrical and Electronic Engineering 2015; 3(2-1): 72-77 Published online February 9, 2015 (http://www.sciencepublishinggroup.com/j/jeee) doi: 10.11648/j.jeee.s.2015030201.26 ISSN: 2329-1613

More information

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY 9. INTRODUCTION Control Cabling The protection and control equipment in power plants and substations is influenced by various of environmental conditions. One of the most significant environmental factor

More information

LOVAG GENERAL INSTRUCTION G2 MEASUREMENT UNCERTAINTY. This instruction of a general nature and does not relate to specific standards.

LOVAG GENERAL INSTRUCTION G2 MEASUREMENT UNCERTAINTY. This instruction of a general nature and does not relate to specific standards. LTI-G2 LOVAG GENERAL INSTRUCTION G2 MEASUREMENT UNCERTAINTY This instruction of a general nature and does not relate to specific standards. It provides additional information ensuring a suitable degree

More information

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Location(s) where activities are performed under accreditation Head ffice Vijzelmolenlaan 7 3447 GX oerden The Netherlands Location Abbreviation/ location Vijzelmolenlaan 7 3447 GX oerden The Netherlands

More information

02/11/2015

02/11/2015 35 mm - 2 Relays 8A PL2R1 Part number 88867455 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17LLBM asymmetrical flashing relay s V AC - solid state output Characteristics asymmetrical flashing relay - 0.1..1 s - 24..240 V AC - solid state output Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 75.00 USD Main Range

More information

INTERNATIONAL. High-voltage test techniques Partial discharge measurements

INTERNATIONAL. High-voltage test techniques Partial discharge measurements INTERNATIONAL STANDARD IEC 60270 Third edition 2000-12 High-voltage test techniques Partial discharge measurements This English-language version is derived from the original bilingual publication by leaving

More information

ESD9N12BA ESD9N12BA. Descriptions. Features. Applications. Order information. http//:

ESD9N12BA ESD9N12BA. Descriptions. Features. Applications. Order information. http//: 1-Line, Bi-directional, Transient Voltage Suppressors http//:www.sh-willsemi.com Descriptions The ES9N12BA is a TVS (Transient Voltage Suppressor) designed to protect sensitive electronic components which

More information

Center for Quality Engineering. Test Report No.: B0EF0002

Center for Quality Engineering. Test Report No.: B0EF0002 DAT-P-002/91-02 Center for Quality Engineering Order No.: B0EF Pages: 10 Munich, Aug 22, 2008 Client: Infineon Technologies AG OP TTR RPT 2 Equipment Under Test: Manufacturer: Task: Test Specifications:

More information

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 24..240 V AC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 62.00 USD Main Range of product Product

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic inspection Evaluating electronic characteristics of ultrasonic test instruments

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic inspection Evaluating electronic characteristics of ultrasonic test instruments INTERNATIONAL STANDARD ISO 12710 First edition 2002-09-15 Non-destructive testing Ultrasonic inspection Evaluating electronic characteristics of ultrasonic test instruments Essais non destructifs Contrôle

More information

OLD BUSINESS

OLD BUSINESS 2010-09-28 IEEE PES Switchgear Committee, HVCB, C37.11 Meeting in Las Vegas, NV 1. Welcome and introductions of all participants. The WG meeting was attended by xx participants; xx members and xx guests.

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60060-3 First edition 2006-02 High-voltage test techniques Part 3: Definitions and requirements for on-site testing Reference number IEC 60060-3:2006(E) Publication numbering

More information

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual REK 50 protection of a synchronous machine User s Manual REK 50 X 0 9 8 7 6 5 4 0 V 00 V 0 V 5 6 7 Ordering No: REK 50-AA Uau = 00/0 Vac Un = 48 V Serial No: fn = 50/60 Hz Uec = ma 600 Vdc MRS 75587-MUM

More information

Test Specification for Type Approval

Test Specification for Type Approval A2 (1991) (Rev.1 1993) (Rev.2 1997) (Rev. 2.1 July 1999) (Rev.3 May 2001) (Corr.1 July 2003) (Rev.4 May 2004) (Rev.5 Dec 2006) (Rev.6 Oct 2014) Test Specification for Type Approval.1 General This Test

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Normative document: EN IS/IEC 17025:2005 Location(s) where activities are performed under accreditation Head ffice Vijzelmolenlaan 7 3447 GX oerden The Netherlands Location Abbreviation/ location Vijzelmolenlaan

More information

MID energy meter B21 Single-phase energy meter, 65 A

MID energy meter B21 Single-phase energy meter, 65 A MID energy meter B2 Single-phase energy meter, 5 Single-phase energy meter ( + ) Direct connection up to 5 Width, 2 DI modules Tested and approved per MID * and IEC * Regional different requirements apply

More information

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay Overcurrent Protection / 7SJ46 SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay Function overview Fig. /11 Description The SIPROTEC easy 7SJ46 is a numerical overcurrent protection relay which

More information

Standardisation and Immunity Tests regarding IEMI

Standardisation and Immunity Tests regarding IEMI Standardisation and Immunity Tests regarding IEMI Véronique Beauvois ULG ERTMS: European Railway Traffic Management System ERTMS = Unique signalling standards throughout Europe M O D E M GSM-R Data and

More information

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES 23 CHAPTER 2 v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES 2.1 INTRODUCTION For reliable design of power system, proper insulation coordination among the power system equipment is necessary. Insulation

More information

22/10/2012

22/10/2012 22.5 mm DIN rail mounting TUR1 Part number 88865105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator Option of connecting an external power supply

More information

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer

More information

Insulation Level and Test Technology of. 1000kV Power Transformer

Insulation Level and Test Technology of. 1000kV Power Transformer Insulation Level and Test Technology of 1000kV Power Transformer Li Guangfan, Wang Xiaoning, Li Peng et al HIMALAYAL - SHANGHAI - CHINA Abstract: The insulation coordination for the first 1000kV UHVAC

More information

NORME INTERNATIONALE INTERNATIONAL STANDARD

NORME INTERNATIONALE INTERNATIONAL STANDARD NORME INTERNATIONALE INTERNATIONAL STANDARD CEI IEC 61000-4-4 Deuxième édition Second edition 2004-07 PUBLICATION FONDAMENTALE EN CEM BASIC EMC PUBLICATION Compatibilité électromagnétique (CEM) Partie

More information

02/11/2015

02/11/2015 17.5 mm - 1 Relay 5A EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer

More information

DRAFT REGULATORY GUIDE DG-1029

DRAFT REGULATORY GUIDE DG-1029 123-0079.htm at ruleforum.llnl.gov Page 1 of 31 U.S. NUCLEAR REGULATORY COMMISSION February 1998 OFFICE OF NUCLEAR REGULATORY RESEARCH Division 1 Draft DG-1029 DRAFT REGULATORY GUIDE Contact: C.E. Antonescu

More information

TECHNICAL REQUIREMENTS FOR IMMUNITY OF TELECOMMUNICATIONS EQUIPMENT

TECHNICAL REQUIREMENTS FOR IMMUNITY OF TELECOMMUNICATIONS EQUIPMENT TECHNICAL REQUIREMENTS FOR IMMUNITY OF TELECOMMUNICATIONS EQUIPMENT TR NO. 549001 Edition 3.2 3rd, September, 2018 Nippon Telegraph and Telephone Corporation NOTICE This document provides a summary of

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China 4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR

More information

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC TS 60071-5 First edition 2002-06 Insulation co-ordination Part 5: Procedures for high-voltage direct current (HVDC) converter stations Coordination de l isolement - Partie 5:

More information

05/09/2012

05/09/2012 17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option

More information

INDEX. 1. Electrostatic discharge immunity test E-1 ~ 2 (IEC )

INDEX. 1. Electrostatic discharge immunity test E-1 ~ 2 (IEC ) INDEX PAGE 1. Electrostatic discharge immunity test - - - - - - - - - - - - - - - - - - - - - - - - - E-1 ~ 2 (IEC61000-4-2) 2. Radiated, radio-frequency, electromagnetic field immunity test - - - - -

More information

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2. Conforms to EMC standards (EN50081-2 and EN50082-2). Approved by UL and CSA. Lloyds/NK

More information

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC standards. Presented by: Karim Loukil & Kaïs Siala Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards

More information

DC/DC CONVERTER Industrial/Electricity Related Application

DC/DC CONVERTER Industrial/Electricity Related Application DCDC CONVERTER IndustrialElectricity Related pplication pplication Using Modular DCDC Converter for IndustrialElectricity Related pplications - General - Introduction This application note underlines the

More information

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento Sept. 22-24, 28, Florence, Italy EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS C. Ceretta, R. Gobbo, G. Pesavento Dept. of Electrical Engineering University of

More information

Transient Data Acquisition System, TAS 4-40 Potential-free measurement of fast rise pulses:

Transient Data Acquisition System, TAS 4-40 Potential-free measurement of fast rise pulses: Transient Data Acquisition System, TAS 4-40 Potential-free measurement of fast rise pulses: High precision measurement of fast rising voltages and currents causes considerable problems in many spheres

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

RF Conducted Immunity and Automotive Transient Generator Test Systems

RF Conducted Immunity and Automotive Transient Generator Test Systems August 2008 RF Conducted Immunity and Automotive Transient Generator Test Systems rf/microwave instrumentation 1 This Will Get Your Pulse Going at whatever rate you need! DUT Coupling Network TGA20000

More information

THT TYPE. Interface unit with built-in DO module FEATURES

THT TYPE. Interface unit with built-in DO module FEATURES INTERFACE UNIT THT TYPE FEATURES Both and DO modules of the THT type interface unit have the same structure, providing a smart appearance. The connector sockets and operation indicators are located at

More information

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2 INDEX PAGE 1. Electro-Static Discharge Test EN61000-4-2.. R-1 2. Radiated Susceptibility Test EN61000-4-3 R-2 3. Electrical Fast Transient Burst Test EN61000-4-4 R-3 4. Surge Test EN61000-4-5 R-4 5. Conducted

More information

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE Z.Liu, B.T.Phung, T.R.Blackburn and R.E.James School of Electrical Engineering and Telecommuniications University of New South Wales

More information

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE Page 1 of 18 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 42.90 USD Main Range of product Product or component

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result

More information

2.1 General Specifications

2.1 General Specifications Chapter 2. 2.1 General Specifications Table 2.1 shows general specifications of the GLOFA GM series and MASTER-K series. No Item Specifications Standards 1 2 3 4 Operating ambient temperature Storage ambient

More information

Electromagnetic Compatibility of Power Converters

Electromagnetic Compatibility of Power Converters Published by CERN in the Proceedings of the CAS-CERN Accelerator School: Power Converters, Baden, Switzerland, 7 14 May 2014, edited by R. Bailey, CERN-2015-003 (CERN, Geneva, 2015) Electromagnetic Compatibility

More information

6V8 * ESDA6V8UD ESDA6V8UD. Descriptions. Features. Order information. Applications. http//:

6V8 * ESDA6V8UD ESDA6V8UD. Descriptions. Features. Order information. Applications. http//: 4-Lines, Uni-directional, Ultra-low Capacitance Transient Voltage Suppressors http//:www.sh-willsemi.com Descriptions The is an ultra-low capacitance TVS (Transient Voltage Suppressor) array designed to

More information