V V NPE-280 V FS-280 V NPE+FS-280. Surge Protective Device
|
|
- Norma Stewart
- 5 years ago
- Views:
Transcription
1 V V FS-80 V FS-80 Surge Protective Device DE Installationsanleitung E Installation instructions ES Instrucciones de instalación RU Инструкция по установке FR otice d installation L Installatiehandleiding IT Istruzioni di installazione PT Instruções de instalação DA Installationsvejledning SV Installationsinstruktion O Installasjonsanvisning FI Asennusohje CS ávod k instalaci HU Szerelési útmutató PL Instrukcja instalacji SR Uputstvo za instalaciju HR Upute za instalaciju RO Instrucţiuni de instalare BG Ръководство за монтаж TR Kurulum talimatı ZH 安装说明书
2 Code click ok click red ok Recycling 3 4 b a + b.0 m a c F c.0 m Pozidriv PZ 4 m 35 lbs-in I L 50 A mm F 5 V50..+FS.. 0. m.7 lbs-in AC: 50 V / A DC: 50 V / 0. A 5 V / 0. A 75 V / 0.5 A mm² AWG 6 Cu 7 mm OBO BETTERMA GmbH & Co. KG
3 7 T-C 6 mm² mm² I < 00 μa L L L3 I Total (8/0) : 60 ka I Total (0/350) : 50 ka I < 500 μa L L L3 L L L3 F F L' L' L3' ' L L L3 F F L' L' L3' ' ' 8 T-S / TT + 6 mm² 6 mm² + I Total (8/0) : 50 ka I Total (0/350) : 50 ka I < μa L I Total (8/0) : 50 ka I Total (0/350) : 50 ka I < μa L L L F F L' ' ' L L F F L' L' ' ' 3 6 mm² 3 + I Total (8/0) : 50 ka I Total (0/350) : 50 ka I < μa L L L3 L L L3 F F L' L' L3' ' ' OBO BETTERMA GmbH & Co. KG 3
4 Dimensions / Abmessungen The sizes stated in drawings refer to millimeters (mm). / Die Größenangaben in den Maßzeichnungen sind in Millimetern (mm) angegeben. OBO BETTERMA GmbH & Co. KG 4
5 Installation instructions E Surge protection device Item no. Type Product Protection path I Total 8/0 I Total 0/350 Circuit diagram V Single arrester* V Three-pole L / 0 ka 37.5 ka V Four-pole L, 60 ka 50 ka V Single-pole with L, 50 ka 50 ka V Two-pole with L, 50 ka 50 ka V Three-pole with L, 50 ka 50 ka V50-3+FS-80 Three-pole with FS L / 0 ka 37.5 ka V50-4+FS-80 4-pole with FS L, 60 ka 50 ka Single-pole with / V50-++FS-80 FS L, 50 ka 50 ka Three-pole with / V50-3++FS-80 FS L, 50 ka 50 ka C Single arrester* *Figure E Product description Lightning current and surge protection device for equipotential bonding of power supply systems according to VDE (IEC ) and for lightning protection equipotential bonding according to VDE (IEC 6305). For mounting on hat rails and use in distributor housings. Arresters (Figure ) can be connected individually and are encoded on the rear side, in order to avoid incorrect connection. They possess a thermodynamic cut-off unit and have an arresting capacity of up to 40 ka (8/0) and.5 ka (0/350) per pole. If there is an error, the visual display switches from grey to red (Figure ). With snap-on hat rail bracket (Figure ). The spark gap C is intended as an arrester between the neutral conductor and the protective conductor ( conductor). Only V50-..+FS..: With module for remote signalling through potential-free changeover contact (Figure ). Target group The device may only be mounted and connected by an electrical technician. General safety information Before working on power cables, ensure that they are de-energised and secure them against unintentional switch-on! Do not carry out mounting work during a storm! Comply with national laws and standards, e.g. VDE (HD )! Mounting and installation The device can be installed in any position (e.g. vertical or horizontal). Figure : VDE (HD ) specifies that, in the case of single-branch wiring, the total connection length a + b or, in the case of V wiring, the connection length c should ideally not exceed 0.5 m, but never exceed.0 m. For V wiring, use the connection terminal, item no Caution! Risk of overloading! The connection terminal is approved for a maximum current load 50 A. Use a suitable back-up fuse! OBO BETTERMA GmbH & Co. KG 8
6 Installation instructions Clamp the protection device onto the hat rail, ensuring that the lockable hat rail holder is unlocked (Figure ). Maintain the stripping length and tightening torque (Figure ). Connection according to the circuit diagram (T-C systems) or (T-S/ TT systems). Dismantling Figure : Unlock and remove arresters in the manner shown. Open the hat rail holder with a flat screwdriver and engage it (see also Figure ). Remove the protection devices. Faults If the integrated cut-off unit trips (e.g. due to age on account of multiple, very high overvoltages), the visual display (Figure ) switches from grey to red. In this case, remove the arrester and insert a new arrester (available separately, V50: item no , C50: item no ). In the case of devices with multiple arresters, it must be assumed that the other arresters of this device have experienced the same load. We recommend that you check them and, if necessary, also replace them. Dispose of replaced arresters. Remote signalling Figure (only V50-..+FS..): When at least one arrester is disconnected, the changeover contact in the remote signalling module switches from / to /4. Remote signalling can be switched as an O or C contact. This allows control of suitable signalling components (e.g. central error messages, light or acoustic signal). Connect the remote signalling cables as shown, in so doing maintaining the specified cable cross-section and the stripping length. Maintenance We recommend carrying out a visual check of the visual display every -4 years or after lightning strikes. Disposal Packaging as household waste Protection device/arrester as electronic waste. Comply with the local waste disposal regulations. Technical data V C50 IEC / DI E Class I + II / Type + U C 80 V AC 55 V AC U 30 V AC (± 0 %) U P 300 V ka 8/0 700 V U res 5 ka 8/ ka 8/0 900 V,5 ka 8/0 000 V I imp.5 ka 50 ka I n 30 ka 50 ka I max 50 ka 50 ka I SCCR 50 ka eff IP code IP 0 (built-in) Einbauort/ installation point Innenraum/indoor umber of Ports One-Port-SPD System T-, TT T-, TT () C F 5 95 % L Protection path L Protection path L x x x,5 mm to metal parts/devices F >60 A F + F gl / gg F 60 A gl / gg () F F F 60 A gl / gg () a.5 35 mm (AWG 6 ).5 35 mm (AWG 6 ).5 35 mm (AWG 6 ) Accessories a 5.5 mm (0.6 in) 3 x 6 mm (3 x AWG 6) E OBO BETTERMA GmbH & Co. KG 9
OBJ_BUCH book Page 3 Monday, August 2, :46 PM 1 2 A B
TruTool N 160 E de Originalbetriebsanleitung en Original instructions fr Notice originale es Manual original pt Manual original it Istruzioni originali nl Oorspronkelijke gebruiksaanwijzing da Original
More information7P Series - Surge Protection Device (SPD) Features 7P P P
Features 7P.09.1.255.0100 7P.01.8.260.1025 7P.02.8.260.1025 SPD Type 1+2 Surge arrester range - single phase system / three phase system Surge arresters suitable in low-voltage applications in order to
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More informationMounting Guide ThermoControl 3
Mounting Guide ThermoControl 3 Warning! Before beginning any work, read this mounting guide and any associated installation guides. Before starting up the device, make sure that it is free from defects
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationDC-EX125 Bedienungsanleitung 1 4 Operating instructions 5 8 Mode d emploi 9 12 Istruzioni d uso Gebruiksaanwijzing 17 20
DC-EX5 *78* 78 D GB F I NL P E DK SF N S GR BG HR PL RUS SK SLO CZ H Bedienungsanleitung Operating instructions 5 8 Mode d emploi 9 Istruzioni d uso 6 Gebruiksaanwijzing 7 Manual de instruções Manual de
More informationMultiMeter-Pocket CAT III 1000 V
02 10 18 26 34 42 50 58 66 74 82 DE GB NL DK FR ES IT PL FI PT SE AC DC AC DC CAT III 1000 V 90 98 106 114 122 130 138 146 154 162 170 NO TR RU UA CZ EE LV LT RO BG GR ! Read the operating instructions
More informationTransformers, Power Supply Units and Socket Outlets
Transformers, Power Supply Units and Socket Outlets /2 Introduction /3 4AC3 bell transformers /4 4AC3 safety transformers /5 4AC2 power supply units /6 5TE6 REG socket outlets For further technical product
More informationFIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented
Doepke The experts in residual current protection technology Residual Current Circuit-Breakers it- r with Overcurrent Protection (RCBO) FIB / FIC» effi cient» reliable» fl exible» future-oriented Doepke
More informationJ7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947
Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit
More informationTitle page, Product innovations Product innovations. 14 OBO Neuheiten 2016 / en / 01/03/2016 (LLExport_04360) / 01/03/2016
Title page, Product innovations 206 Product innovations 4 OBO Neuheiten 206 / en / 0/03/206 (LLExport_04360) / 0/03/206 Catalogue 206 Through our products, we create connections around the world. Experience
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More information400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka
Low voltage NV/NH knife-blade fuse-links Electrical characteristics Rated voltage U n 00 Va.c., 500 Va.c., 90 V a.c. Rated current I n - 0 A Breaking capacity at 1,1 U n ka Fusing characteristics gg, am,
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationPower supply CP-T 24/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationUNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description
Primary-switched power supply unit Data sheet 106261_en_02 PHOEIX COTACT 2015-05-13 1 Description The power supply makes a worldwide impression thanks to maximum energy efficiency. ow idling losses (o
More informationPower supply CP-T 24/40.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationPower supply CP-T 24/10.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationCapacitor Switching Contactors
Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..
More informationControl module CP-A CM
Control module 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP-A RU Adjustable threshold values (14-28 V) and relay outputs per input / channel Approvals Marks g 6 7 1 3 4 2 8 5 Order data
More informationCurrent monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationThree-phase monitoring relay CM-PFS
Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available
More information4 mm 1. Ø 24 mm. 3 Nm. B+4 mm H+3 mm. 12 mm. 12 mm
S4 5 B 1 1 2 4 mm 1 2 h W h W 3 3 6 4 2 H B B B+4 mm H+3 mm 7 C D 12 mm 12 mm Ø 24 mm 3 8 B 1. 2. 4 W 1 3 Nm 2 9 b 2. 1. 1 0 c 2. 1. 1. 3. d a 1. 2. 2. 1. Dometic WECO International GmbH Hollefeldstrasse
More informationType: DILM40(RDC24) Article No.:
Type: DILM40(RDC24) Article No.: 277780 Ordering information Rated operational current AC 3 400 V I e A 40 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationHeki2-IO-16s.book Seite 1 Montag, 28. November : Heki mm mm. Ø 130 mm. 655 mm 65 mm. 65 mm. 1,5 Nm
Heki2-IO-16s.book Seite 1 Montag, 28. November 2016 8:57 20 Heki2 5 1 1 5 1 2 mm 4 2 3 6 2 B 960 mm Ø 130 mm 7 655 mm 65 mm 65 mm C 3 8 B 2. 1. 9 4 W 1,5 Nm 1 Heki2-IO-16s.book Seite 2 Montag, 28. November
More informationMINI-PS AC/24DC/1.3
Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationPower supply CP-E 12/10.0 Primary switch mode power supply Data sheet
2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer
More informationCurrent monitoring relays CM-SRS.1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationDatasheet WPDB Power Distribution Blocks
Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best
More informationFuse Links NV/NH gg with Striker Pin Dimensions
D E I A 9,8 G J H l l Fuse Links Electrical characteristics Rated voltage U n Rated current I n reaking capacity U n Melting characteristic ertified In accordance with Dimensions according to Two versions
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationUse of application-optimised type 1 combined arresters in low-voltage installations
Use of application-optimised type 1 combined arresters White Paper Contents Use of prewired and application-optimised DEHNshield combined arresters with spark gap technology Examples: Under-road radiators
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More information8 Input/8 Output AC Block I/O Module
8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationDatasheet WPDB Power Distribution Blocks
Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationPosition switches FM series
B Position switches FM series Selection diagram 0 08 0 A A 0 A 0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket 69 stainless steel round rod square rod fiber
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More informationPower supply CP-T 48/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More information6. Internal lightning protection
6. Internal lightning protection 6.1 Equipotential bonding for metal installations Equipotential bonding according to IEC 60364-4- 41 and IEC 60364-5-54 Equipotential bonding is required for all newly
More informationMeasuring current transformers of the W B series
Measuring current transformers of the W B series W-B_D00075_01_D_XXEN/09.2015 Measuring current transformers of the W B series Product description Measuring current transformers of the W B series are highly
More informationPower supply CP-T 48/5.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR
ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR The flexibility of the Zucchini MS range during planning and installation makes it ideal for frequently changing requirements in small to medium sized commercial
More informationFM series position switches
FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass
More informationThree-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-
More informationMulti-Stand MSA 200. tritontools.com. Key Specifications. Selling Points
Multi-Stand MSA 200 Multi-purpose, adjustable support stand with extra-wide tripod base for excellent stability on level or uneven ground. Folds down in seconds for convenient transportation and storage.
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationSTEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features
Uninterruptible power supply Data sheet 105623_en_00 PHOENIX CTACT 2013-06-07 1 Description Uninterruptible power supply units continue to deliver power even in the event of mains breakdowns or failures.
More informationPRACTICAL GUIDE. Low-voltage power systems Protection against overvoltages
PRACTICAL GUIDE Low-voltage power systems Protection against overvoltages Introduction Overvoltage Since the 1960s, the purely technical term EMC (electromagnetic compatibility) has become a term comprising
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.23
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 The three-phase monitoring relay CM-MPS.23 monitors the phase parameters phase sequence, phase failure, over- and undervoltage
More informationMeasuring current transformers of the W, W series
Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43 The three-phase monitoring relays CM-MPS.x3 monitor the phase parameters phase sequence, phase failure, over- and
More informationQUINT-PS/ 3AC/24DC/40
Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum
More informationSurge Protection Device (SPD) 7P
Surge Protection Device (SPD) SЕRIS Panels for electrical distribution Control panels Surge protection Road / tunnel lighting levators and lifts FINDR reserves the right to alter characteristics at any
More informationMiniature circuit-breakers S 280 UC series. System pro M. Technical data
Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationThree-phase monitoring relays CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More informationType: DILEM 10(220V50HZ,240V60HZ) Article No.:
Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More informationAdd-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.
2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage
More informationTGC. Measuring of locations TYPE:
TGC UK Installation Instructions FI Asennusohje LV Instalacijas instrukcija DE Montageanleitung FR Notice de montage NO Monteringsanvisning CZ Montážní návod HU Szerelési útmutató PL Instrukcja montażu
More informationInstallation and Operational Instructions for ROBA -switch Type 017._00.2
OBA -switch Type 017._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EC Low Voltage Directive 2014/35/ EC and the EMC Directive
More informationMini Heki Plus. Dachfenster Montage- und Bedienungsanleitung. 2. Roof light Installation and Operating Manual.. 10
DE Dachfenster Montage- und Bedienungsanleitung. 2 Roof light Installation and Operating Manual.. 10 FR Dôme de toit Instructions de montage et de service.................. 17 ES Claraboya Instrucciones
More information24V dc Analog Block I/O Module
24V dc Analog Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module. Refer
More informationModeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS
OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS P Other accessories DELAY UNIT Type Product code Description Weight [kg] Package [pc] BZ-BX-X230-A 36696 enables to delay the undervoltage release tripping
More informationType: DILEM 10 G(24VDC) Article No.:
Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220
More informationPower supply CP-E 48/5.0 Primary switch mode power supply Data sheet
2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated
More informationInstallation and Operating Instructions for Phase Demodulator Type _.2
Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility (EMC)
More informationCentral Inverter SUNNY CENTRAL 200 / 250 / 250HE / 350
Central Inverter SUNNY CENTRAL 200 / 250 / 250HE / 350 Installation Guide SC20_25_35-IEN094521 98-4004821 Version 2.1 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Manual..............................
More informationControls Contactors and Contactor Assemblies Special Applications
Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationBtdin RCD Add-on modules 63A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More informationBlock-800B bass head. user manual
Block-800B bass head user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Deutschland Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 08.03.2018,
More informationDT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions
DT1100 E xx xx (PS) Galvanic Isolators Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized
More informationOperating Instructions CAMILLE BAUER METRAWATT METRAOHM /9.97. Low impedance resistance meas. instrument
Operating Instructions METRAOHM 413 Low impedance resistance meas. instrument GOSSEN METRAWATT CAMILLE BAUER 3-348-776-37 2/9.97 V 8 6 5 4 20 200 PE-TEST 7 1 20 200 + /- METRAOHM 413 3 2 10 9 1 Measurement
More informationProtection components
General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationPower supply CP-D 24/4.2 Primary switch mode power supply
Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution
More informationPower supply CP-D 12/2.1
2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power
More informationDigital Function Generator
Digital Function Generator 13654-99 PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 37079 Göttingen Germany Tel. +49 (0) 551 604-0 Fax +49 (0) 551 604-107 E-mail info@phywe.de Operating Instructions
More informationMINI-PS AC/2X15DC/1
MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths
More informationDT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions
Isolators, Isolator / Power Supplies Operating Instructions EN Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized
More information11/0 IZM circuit-breakers, IN switch-disconnectors
11/0 IZM circuit-breakers, IN switch-disconnectors Contents IZM circuit-breakers, IN switch-disconnectors 11/1 from 630 A 6300 A Page Description 11/2 Technical overview 11/4 Overview of functions for
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationInstallation / Monitoring Technique
Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationPACPC1 INSTALLATION INSTRUCTIONS. Power Conditioner Accessory. Instrucciones de instalación Installationsanleitung Instruções de Instalação
INSTALLATION INSTRUCTIONS Instrucciones de instalación Installationsanleitung Instruções de Instalação Istruzioni di installazione Installatie-instructies Instructions d installation Power Conditioner
More informationNEW CIRCUIT PROTECTIONRANGE
NEW CIRCUIT PROTECTIONRANGE TRUSTED PROTECTION FOR YOUR RESIDENTIAL AND COMMERCIAL INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW RCBO, RCCB AND MCB RANGE PROTECTION
More informationBRU-100 Physical Installation
APPENDIX B BRU-100 In This Appendix: Warnings and Cautions, page 50, page 51 Check List, page 57 This appendix provides guidance for the physical installation of the BRU-100 Remote Unit at a subscriber
More informationIndex. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6
Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram
More informationTable of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance
Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8
More information