P.F. REGULATOR MICROPROCESSOR BASED PR-7D SERIES
|
|
- Arthur Benson
- 5 years ago
- Views:
Transcription
1
2 Power factor regulator PR-7D and PR-7D12 series permit the visualization on a digital display of power system cos ϕ, and the automatic connection of capacitors in function of this cos ϕ. Cos ϕ C/K Setting Operation Program Setting Delay time for switching on/off operations setting Capacitors steps setting Manual Mode Cursor keys (Conection/Manual Disconnection) Setup Key SETUP Setup key: - Long press To enter and exit Setup. - Short press: To move from display mode/editing mode. Cursores: - Cursors to move within the screens in display mode or to edit parameter in edit mode. Visualization / Edition: Simbol showing which parameter is being displayed/edited. Long press of the Setup key for (more than 1 seconds) accesses the adjustment screens if all the capacitors are disconnected, otherwise stars disconnection sequense and then accesses to setup menu. If any key is not pressed in 12 seconds, the equipment leaves the SETUP. Screen 1. Editing Cos ϕ 0.85L to -0.95C (2 quadrants) Screen 2. Adjusting reactive current C/K. Ratio 1 st step. I of the first C / (Ip/Is) of the trans.. Limits:
3 Screen 3. Programing: 1:1:1:1:1; 1:2:2..:2; 1:2:4:4:4; 1:1:2..:2..:2; 1:2:4:8: Screen 4. Connection time between steps. ( 4 to 999 sec). T disconnection = 5 times T connection Screen 5. Relay number selection. Model PR-7D6:6; Model PR-7D12:12. 3 C1 C2 C3 3 NOTE: Outside SETUP menu, when the two keys steps connected are displayed. are pressed simultaneously, the number of ERROR CODES Code Display Description Operate 000 Displays 3 zero Load current below minimum or current transformer not connected E.01 E.02 E.03 Cos ϕ alternate with E.01 blinking Cos ϕ alternate with E.02 blinking Cos ϕ alternate with E.03 blinking Conecction error or current transformer in not valid phase overcompensation. Ask to disconnect and all the relays are disconnected. Undercompensation. Ask to connect and all the relays are connected Automatic relay disconnection Automatic relay disconnection Nothing Nothing -3-
4 CODE REG06DPR TYPE PR-7D PR-7D-6 PR-7D6 (144 x 144) Connection Diagram PR-7D6-4-
5 CODE REG12DPR TYPE PR-7D PR-7D-12 PR-7D12 (144 x 144) Connection Diagram PR-7D12-5-
6 Back view PR-7D6 PR-7D12 Dimensions mm A B C D PR7D 144x
7 TECHNICAL CHARACTERISTICS Supply voltage VAC +15% -10% Frequency Hz Measurement Margin Voltage (VL23) VAC +15% -10% Voltage Measurement Accuracy % Current Measurement Margin (IL1) ,1 a 5A (max. +20%) Accuracy of Current Measurement % Accuracy Cos ϕ Measurement % ± 1 digit Frequency Margin Hz Current Circuit Transformer Current, In/5 Power Consumption VA (PR-7D6); 10 VA (PR-7D12) Voltage Input Between S and T Current Trans conection phase R Display Line x 3 digit, 7 segments, 20 display icons Standards EN 61010; EN ; EN ; EN ; EN ; EN ; EN ; EN ; EN EN ; EN ; UL 94; Installation Category III Pollution Degree IP (Protection) Control Integrated System FCP C/K TABLE CT Power in kvar of first step at 400V Ratio /5 0,12 0,24 0,36 0,48 0,60 0, /5 0,09 0,18 0,27 0,36 0,45 0,54 0,72 0,90 250/5 0,07 0,14 0,22 0,29 0,36 0,43 0,58 0,72 0,87 300/5 0,06 0,12 0,18 0,24 0,30 0,36 0,48 0,60 0,72 0,90 0,96 400/5 0,05 0,09 0,14 0,18 0,23 0,24 0,36 0,48 0,58 0,67 0,72 0,87 500/5 0,07 0,11 0,14 0,18 0,22 0,29 0,36 0,45 0,54 0,54 0,72 0,87 600/5 0,06 0,09 0,12 0,15 0,18 0,24 0,30 0,36 0,45 0,48 0,60 0,72 0,90 0,96 800/5 0,07 0,09 0,11 0,14 0,18 0,23 0,27 0,33 0,36 0,45 0,54 0,68 0, /5 0,05 0,07 0,09 0,11 0,14 0,18 0,22 0,27 0,29 0,36 0,43 0,54 0, /5 0,05 0,06 0,07 0,10 0,12 0,14 0,18 0,19 0,24 0,29 0,36 0, /5 0,05 0,07 0,09 0,11 0,13 0,14 0,18 0,22 0,27 0, /5 0,06 0,07 0,09 0,10 0,12 0,14 0,17 0,22 0, /5 0,05 0,06 0,07 0,09 0,10 0,12 0,14 0,18 0, /5 0,05 0,06 0,07 0,09 0,11 0,14 0,14 C/K Setting It Transformer ratio: Example: 5 = K 500 It = Primary current of C.T. transformer 5 = K = 100 Ic Reactive current adjustmen t: C/K = 1 capacitor: 60 kvar 400V = 86,7 A K Ic 86,7 C/K = = = 0,867 Ic =Current of the first capacitor stage. K
8 INSTALLATION DIAGRAM SPAIN RTR Energía, S.L. Gavilanes, 11 Bis Pol. Ind. Pinto-Estación PINTO (Madrid) Tel.: Fax: CHILE RTR DNA Chile, S.A. La Estera nº 668 Panamericana Norte. Km 17 Loteo Valle Grande - Lampa, CHILE Tel.: Fax: dnachile@rtr.cl RTR Energía S.L. keeps the right to modify in any form or by any means all the information published in this catalogue without prior notice. Any accepted material to be returned, will be paid in origin. If a devolution is produced by any cause NOT imputable to RTR Energía S.L. the total sale price of the material subjet to devolution will be depreciated 10% in concept of expensens. In those cases in which any material is stored for checking or reparation, the customer must inform by writing, within three months after RTR Energía S.L. sends the appropriate budget or report regarding these materials, about the actions to undertake on such items. Otherwise, RTR Energía S.L. keeps the right to destroy these materials.
POWER FACTOR CONTROLLER PR-2D SERIES
INDEX General.......................................................................pag. 3 General application characteristics...............................................pag. 3 Application...................................................................pag.
More informationComputer-14d - xx - 144a
POWER FACTOR REGULATOR Computer-14d - xx - 144a INSTRUCTION MANUAL ( M 981 602 / 98B ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14d --------- Page 2 1.- POWER FACTOR REGULATORS COMPUTER-14d-144a
More informationMounting Instructions / Manual MV1171
Mounting Instructions / Manual MV1171 POWER FACTOR Controller ESTAmat MH-N Vishay Electronic GmbH ESTA Capacitors Division Revision: 19-April-2011 Hofmark-Aich-Strasse 36 84030 Landshut, Germany Phone
More informationSUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.
SUPPLY NETWORK ANALYZER CVMk SERIES & CVMk-4C SERIES INSTRUCTION MANUAL ( M 981 171 / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A. ----- Supply network analyzer CVMk and CVMk-ITF ------ Manual 1 / 2 --- Page
More informationInstallation and Operating Instructions. Power IT Power Factor Controller RVC
Installation and Operating Instructions Power IT Power Factor Controller RVC Table of contents Page 1. Read this first... 3 About this Instruction Manual... 3 Safety... 3 Electromagnetic compatibility...
More information3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3
More informationALPTEC POWER FACTOR CONTROLLER
ALPTEC POWER FACTOR CONTROLLER ALPTEC3 ALPTEC5 ALPTEC7 ALPTEC12 0 REF : 2008-ALPTEC3.5.7.12-01-ANG CONTENTS I GENERAL INFORMATION. 2 II WAYS TO SET UP THE CONTROLLER.. 4 III OPERATING MODE..6 IV ADVANCED
More informationSUPPLY NETWORK ANALYZER
SUPPLY NETWORK ANALYZER CVM-144 SERIES (Ethernet) (Ver 6.11 and higher) INSTRUCTION MANUAL (M98203401-03-06A) CIRCUTOR S.A. ----- Supply network analyzer CVM-144 ------ User's manual --- Page No. 1 CONTENTS
More informationDPF-MAC Auto power factor controller
Digital Electric& Electronics System DPF-MAC Auto power factor controller MULTI POWER FACTOR AUTOMATIC MULTI POWER FACTOR AUTOMATIC Introduction DPF-MAC increases usage efficiency by controlling the power
More informationINSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12
INSTRUCTION MANUAL Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS Power Factor Controller A12 1. CONTENTS 1. CONTENTS 1 2. FEATURES 2 3. INSTALLATION, CONNECTION AND APPLYING POWER 2 4.
More informationSYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.
SYNCHRONISM RELAY SYNCRO-96 (Code 2 28 913-2 28 914-2 28 915) INSTRUCTION MANUAL ( M 981 196 / 99A ) (c) CIRCUTOR S.A. ----- Synchronism relay SYNCRO-96 -------- M - 981 196 --- Page nº 1 Synchronism relay
More informationSUPPLY NETWORK ANALYZER
SUPPLY NETWORK ANALYZER CVM-144 SERIES (PROFIBUS-DP) INSTRUCTION MANUAL ( M 981 704 / 01A - GB) CIRCUTOR S.A. ----- Supply network analyzer CVM-144 (PROFIBUS) ------ --- Page No. 1 CONTENTS page 1.- DELIVERY
More informationSUPPLY NETWORK ANALYZER CVM-96 SERIES
SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY
More informationULTRA RAPID POWER QUALITY ANALYZER
ULTRA RAPID POWER QUALITY ANALYZER Ultra rapid (cycle by cycle) advanced electrical network analysis Complete network harmonics analysis, up to 63 rd harmonic High visibility, 5 graphic LCD screen with
More informationPower factor correction and harmonic filtering. Automatic power factor regulators R.1
Power factor correction and harmonic filtering Automatic power factor regulators R.1 R.1 Automatic power factor regulators R.1 - Automatic power factor regulators Selection table R1-4 computer Plus-T Intelligent
More informationINTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]
Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High
More informationNSL-10 STANDARD LIFE MODULAR CAPACITORS
ADVANCE P.F. CORRECTION SOLUTIONS FROM NEPTUNE-DUCATI Channel Partner Ph: 02621-234524, 99242 04524 Industrial Trading Co. 10B Dharma Super Market, Kim Char Rasta, Contact : Paresh Gandhi (98241 31205)
More informationCommissioning Instructions Rev. 03
Power Factor regulator BLR-CM-T/RT L1 L2 L3 Einspeisung Supply Last Load BLR-CM-T + - Triggereingang/ Triggerinput BEL-TSXX N PE L1 L2 L3 Einspeisung Supply Last Load BLR-CM-RT + - Triggereingang/ Triggerinput
More informationPower factor correction and harmonic filtering. Automatic power factor regulators
Power factor correction and harmonic filtering Automatic power factor regulators Automatic power factor reguladors R.1 - Automatic power factor regulators Selection table R1-4 computer Plus-T Intelligent
More informationPOWER FACTOR CORRECTION MRM Power factor regulators.
POWER FACTOR CORRECTION MRM - 12 factor regulators www.twelvee.com.pl Introduction Rational reactive power economy in an enterprise requires maintaining cosφ at the level specified in the energy solicitation
More informationENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake
ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate
More informationPower Factor Controller BR 5306 / 5312
Power Factor Controller BR 5306 / 5312 Instruction book 1.GENERAL The BR 53 is equipped with a single-chip micro- computer. This version, which has been additionally improved by a number of new design
More informationREACTIVE ENERGY REGULATOR
REACTIVE ENERGY REGULATOR Controller MASTER control VAR FAST (Static operation) INSTRUCTION MANUAL (M021B02-03-18A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown
More informationTechnical Data Sheet. x1000. kwh R Y B
Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy
More informationPLA 33. Power line analyzer. User and service manual. version 2.4
PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0
More informationFCR 06, FCR 12. Power factor correction controller. User and service manual
FCR 06, FCR 12 Power factor correction controller User and service manual version 2.3 Czech Republic Czech Republic 1 Content 1. Control and signal elements... 3 2. Device description... 4 3. Instruction
More informationMETERSUK. SmartLink D Y N A M i T E. EM735 S Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.
LTD METERSUK sales@meters.co.uk 01524 555 929 EM735 S Series Smart Energy Meter KEY FEATURES METERSUK LTD Three phase metering CE Approved Three Phase metering, 7 din Modules Accuracy class 1 according
More informationV Pg. M1: V, V, V Pg. M1 R1: Relay 1 Pg. M1 R2: Relay 2 (three-phase only) output status output status KW Pg. M2:,, Pg. M2n: neutral Pg. M3: P1, P2, P
Via Vizzano 44-40044 Pontecchio Marconi (Bologna)Italy Tel. +39 051 6782006 - Fax +39 051 845544 http://www.elcontrol-energy.net - e-mail: Italia vendite@elcontrol-energy.net estero: sales@elcontrol-energy.net
More informationESTAmat MH Mounting Instructions MV1151
ESTAmat MH Mounting Instructions MV1151 VISHAY ELECTRONIC GMBH - Geschäftsbereich ROEDERSTEIN, ESTA und Hybride Hofmark-Aich-Str. 36 - Phone (49)-871/86-0 - Fax (49)-871/86 25 12 - D-84030 Landshut - Germany
More informationPower Factor Controller BR 6000
Power Factor Controller BR 6000 Manual Version 2.1 E Power Factor Controller BR6000 Version 2.1E, Oct. 2003 CONTENTS Section 1 General 3 Section 2 Installation of the controller / connection diagram 5
More informationModel φ/1φ Power Clamp-on Meter
User's Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 382075 Product Page Model 382075 3φ/1φ Power Clamp-on
More informationClassification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A
PCB Relay Low-profile power relay with maximum switching of 8 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kv Clearance and creepage distance: 10 mm. RoHS
More informationPFC POWER FACTOR CONTROLLERS POWER NEEDS CONTROL
PFC POWER FCTOR CONTROLLERS POWER NEEDS CONTROL 1 PFC power factor controllers utomatic power factor correction controller series PFC 6, 8, 12 RS DESCRIPTION n essential way of electrical energy cost reduction
More informationRISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:
Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit
More informationVAR INSTRUCTION MANUAL (M015B B)
REACTIVE ENERGY REGULATOR Controller MASTER control VAR INSTRUCTION MANUAL (M015B02-03-18B) 2 SAFETY PRECAUTIONS Followthewarningsdescribedinthismanualwiththesymbolsshownbelow DANGER Warnsofarisk,whichcouldresultinpersonalinjuryormaterialdamage
More informationThe Power Factor Controller BR 6000
The Power Factor Controller BR 6000 User-friendly and Intelligent Controller with Multi-functional Display Product Profile 2002 http://www.epcos.com EPCOS BR 6000 PFC Controller Innovative and intelligent
More informationReactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau
Reactive Power Control Relay RM 2106 / 2112 Operating Instructions FRAKO Kondensatoren- und Anlagenbau www.frako.com Figure 1 Front view a b c d e Display for active capacitor stages Display for inductive
More information400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)
MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.
More informationMeasuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207
Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207 o 7 digits electromechanical register o Up to 2 registers
More informationVIP Current & Power Multimeter
VIP Current & Power Multimeter Rev 1.6 Table of Contents 1. Mechanical Installation... 3 2. Wiring diagram... 4 3. Specifications... 5 Technical Specifications... 5 3.2 Measuring Specifications... 5 4.
More informationAMIK 200 / 201 Technical Data Sheet
AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT
More informationInstallation & Operation Manual ELNet VIP
Installation & Operation Manual ELNet VIP Electrical Measurements Table of Contents 1. Mechanical Installation... 1-3 2. Wiring diagram... 2-5 3. Specifications... 3-6 Technical Specifications... 3-6 Measuring
More informationPM-PA/PM-PAC POWER ANALYZER
PM-PA/PM-PAC POWER ANALYZER 1. INTRODUCTION Power Analyzer is an ideal device to control measure and monitor all electrical parameters of a system. Thanks to its four display rows, all parameters can be
More informationUMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks
Threshold value monitoring Pulse outputs UMG 96L / UMG 96 Universal measurement device Measuring accuracy Energy: Class 2 Current.../1 A,.../5 A Voltage L - N: ± 1 % Networks TN-, TT-Networks 2 digital
More informationInstruction Manual IPM φ/1φ Power Clampmeter EN FR IT DE ES
Instruction Manual IPM 6600 3φ/1φ Power Clampmeter EN FR IT DE ES 0 EN 61010-2-032 CAT III 600V Pollution Degree 2 Definition of Symbols: Caution: Refer to Accompanying Documents Caution: Risk of Electric
More informationPIR6WT-1Z interface - time relays
1 9-functions electronic time relays compliance with standard PN-EN 612-1 Time relay PIR6WT-1Z consists of: - universal socket with electronic PI6WT-1Z with screw terminals, - changeover relay RM699V,
More informationC-80 INSTRUCTION MANUAL
SYSTEM AALYZER C-80 ISTRUCTIO MAUAL (M98117501-03 / 03D) (c) CIRCUTOR S.A. -------------- SYSTEM AALYZER C-80 ----------- Page no. 2 C-80 TABLE OF TETS 1.- ITRODUCTIO.... 3 2.- GEERAL FEATURES... 4 3.-
More informationDATA SHEET Selectable AC transducer TAS-311DG
DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800
More informationDIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis
diris_561_b_3_x_cat 1 1. Backlit LCD display. 2. Direct access key for currents and setup wiring correction. 3. Direct access key for voltages and frequency. 4. Direct access key for active, reactive,
More informationFilm Capacitors Power Factor Correction
Series/Type: Ordering code: Date: 2010-04-12 Version: 3 entered in headers and footers! Please fill in the table and then change the color to "white". This ensures that the table disappears (invisible)
More informationTechnical Manual Modulation Box
Technical Manual Modulation Box Schwank GmbH - Bremerhavener Str. 43-50735 Cologne, Germany Tel: +49 (0)221-7176-0 Fax: +49 (0)221-7176-288 E-mail: info@schwank.de Internet: www.schwank.de Subject to technical
More informationEnergy Management Energy Analyzer Type EM112
Energy Management Energy Analyzer Type EM112 Single phase energy analyzer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement
More informationZiegler EM 1320/30/40
Ziegler EM 1320/30/40 Operating Manual Ziegler EM 1340 2-60-006-00-00483_Rev. C - 9/2014 www.ziegler-instruments.com 1 36 DIGITAL MULTIFUNCTION INSTRUMENT Programmable Multi-function Energy Meter Installation
More informationUniversal measuring transducer
Universal measuring transducer EM4000 Compact housing High accuracy Full galvanic separation MODbus (RS232/RS485) 3 Analogue + 1 Pulse output Direct voltagemeasurement up to 690V 48 hour service EXW ELEQ
More informationElectronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-YDE Star-delta change-over with c/o (SPDT) contact The CT-YDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic
More information1 Digital input (24Vac or dry contact) Inputs
Fan oil Thermostat Fan oil Thermostat Features: Attractive modern look with large LD and backlight Icons driven information and 1 line of text information 2 Pipes Analog, ON/OFF or Floating 4 Pipes Analog,
More informationEnergy Management Modular Power Analyzers Type WM2-96
ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA Energy Management Modular Power Analyzers Type WM2-96 - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Class 1 Modular power analyzer
More informationCOD: MNP27M01V03GBV00 (29/01/03) REVISION 0 PAGE 1 OF
English Inglés CRONOS Jofemar User s Manual COD: MNP27M01V03GBV00 (29/01/03) REVISION 0 PAGE 1 OF 28 WARNING: Read the following instructions carefully before installing the unit : - Before connecting
More informationRAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL
RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1 Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External
More informationperfection by simplicity Catalogue
Catalogue Gineers Ltd. produces series of devices and software for complete setup of remote reading systems. We also produce various measuring and indicating devices for industrial use, standard and unique
More informationOrdering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A
PCB Relay G6RL Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) IEC 60947-5-1, AC-15, DC13 Clearance and creepage distance: 10
More informationPower Quality and Energy Measurement PEM533
Power Quality and Energy Measurement _D00013_02_D_XXEN/11.2014 Power Quality and Energy Measurement 0.5 S Product description The digital universal measuring device is suited for measuring and displaying
More informationRISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters
measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy
More informationCAVA Series USER S MANUAL
ANALYZER OF POWER SUPPLY QUALITY CAVA Series (251 / 252 / 253) USER S MANUAL ( M98120201-20-09A ) (c) CIRCUTOR S.A. ----- Analyzer of power supply quality CAVA-251 / CAVA-252 / CAVA-253 ------- Page No.
More informationDOCUMENTATION. Its affordable price allows you to meet your budget target.
DOCUMENTATION ULCOS is a real concentrate of technology, mixing performance and versatility. It is able to meet your high level expectation, for technical tender specifications. Its affordable price allows
More informationFRONIUS ESPAÑA, S.L.U. Parque Industrial La Laguna. Calle Arroyo del Soto, Leganés. Madrid. SPAIN. PV inverters PRIMO-1
Product Certificate Number Applicant: Series/ 11043-CER FRONIUS ESPAÑA, S.L.U. Parque Industrial La Laguna. Calle Arroyo del Soto, 17. 28914. Leganés. Madrid. SPAIN PV inverters PRIMO-1 Model/ PRIMO 3.0-1,
More informationUser's Manual. Model f/1f Power Clamp-on Meter
User's Manual Model 382075 3f/1f Power Clamp-on Meter Introduction Congratulations on your purchase of the Extech Model 382075 Auto Range Power Clamp-On Meter. Careful use of this device, will provide
More informationMoving Test - MT3000
Moving Test - MT3000 Three-Phase Portable Test System Keep ahead with Modular Design The Modular Concept The MT3000 is based on a real modular design concept to provide the greatest possible flexibility
More informationVarlogic NR6, NR12. Power factor controller. User manual
Varlogic NR6, NR12 Power factor controller User manual Power Factor Controller NR6 / NR12 USER S MANUAL Table of Contents 1. General...3 1.1 Safety...3 1.2 Description...3 2. Installation...5 3. Display...6
More informationDEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions
Installation and start up instructions TAS-311DG Selectable AC transducer Voltage, current, frequency or phase angle transducer Supply voltage up to 690V DEIF A/S Configuration via PC-interface possible
More informationDATA SHEET Reverse power relays, RMP-121D ANSI code 32
DATA SHEET Reverse power relays, RMP-121D ANSI code 32 Protection against "motoring" Single phase measurement LED indication of fault condition Timer-controlled tripping LED indication for activated relay
More informationInstallation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems
Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Tyco Electronics UK Limited Crompton Instruments Freebournes Road, Witham, Essex, CM8 3AH, UK Tel: +44 1376 509 509
More informationPQM3000R Class A network analyzer according to EN for power quality monitoring
Class A network analyzer according to EN 50160 for power quality monitoring Possibility to carry out parameter recording according to EN 50160 Integrated web server for complete device management 4 GB
More informationSACI REACTIVE POWER REGULATORS S.A. DE CONSTRUCCIONES INDUSTRIALES. kvarh
kvarh S.A. DE CONSTRUCCIONES INDUSTRIALES CONTENTS ÍNDICE AUTOMATIC REGULATOR - REG-144... RG.04 AUTOMATIC REGULATOR - REG-96... RG.06 AUTOMATIC REGULATOR - REG-144DA... RG.08 RG-03 REGULATOR REG 144
More informationTEMPERATURE CONTROLLER RE21 TYPE
TEMPERATURE CONTROLLER RE21 TYPE USER S MANUAL 1 2 Contents 1. Application... 5 2. Controller set... 5 3. Preparation of the controller to work... 6 3.1. Safety... 6 3.2. Controller installation... 9 3.3.
More informationRISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:
Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationAPPENDIX APPENDIX A 1
A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple
More informationApplication Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters
Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel
More informationRota-Sonde DC4500. Smart display with Signal level. Easy alignment with Laser Line. Design for the most difficult applications
Scanning HOT METAL DETECTOR Rota-Sonde DC4500 Smart display with Signal level Easy alignment with Laser Line Design for the most difficult applications Very High Sensitivity 360 F Lt 1445 1 Applications
More informationPower Quality and Energy Measurement PEM575
Power Quality and Energy Measurement _D00016_03_D_XXEN/12.2015 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical
More informationMonitoring Electric Network Via Internet
Monitoring Electric Network Via Internet NETWORK ANALYSER let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationTechnical reference. 4-quadrant controller. multicomp F144-NC-1V1C6DO6RO-2. Your partner for network analysis. System I English
Technical reference 4-quadrant controller multicomp F144-NC-1V1C6DO6RO-2 System I English Your partner for network analysis KBR multicomp F144-NC-1V1C6DO6RO-2 KBR Kompensationsanlagenbau GmbH Misprints,
More informationPOWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL
POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK PP, PP and PB ISO 900 C E R T Y F I K A T 4 mm SERVICE MANUAL Contents Page. APPLICATION... 2. BASIC REQUIREMENTS.... TRANSDUCER SET... 4 4. TECHNICAL
More informationPortable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an
EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_02_D_XXEN/11.2018
More informationPower Quality and Energy Measurement PEM575
Power Quality and Energy Measurement _D00016_00_D_XXEN/06.2013 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical
More informationINTELLIGENT POWER FACTOR REGULATOR
INTELLIGENT POWER FACTOR REGULATOR Model- KM-PFR-S-9-04 / KM-PFR-S-9-08 / KM-PFR-S-9-12 FEATURES : Display : Power Factor Line Voltage Input Load Current Precise compensation of Reactive Power with automatic
More informationFilm capacitors Power Factor Correction
Key components PF controller Series/Type: BR6000 V5.0 Ordering code: Date: May 2009 Version: 4 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please
More informationElectronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact
Data sheet Electronic timer CT-SDE Star-delta change-over with n/c + n/o contact The CT-SDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic
More informationTechnical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay
Technical Datasheet RELAY-1 RISHABH k V RESET True RMS Digital Protection Relay RELAY-2 TEST True RMS Measurement RISH Relay V is used to protect against Over Voltage, Under Voltage, Phase Sequence detection,
More informationElNet VIP Current & Power Multimeter
ElNet VIP Current & Power Multimeter Rev 1.7 Table of Contents 1. Mechanical Installation...... 3 2. Wiring diagram........ 4 3. Specifications......... 5 1.3 Technical Specifications...... 5 3.2 Measuring
More informationINSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W
Page 2 / 16 INDEX: GENERAL TYPES ACESSORIES AND OPTIONS INSTALLATION WIRING DIAGRAMS CONNECTING TERMINALS DIAGRAMS WIRING DIAGRAM DESCRIPTION WORKING DESCRIPTION AND KEYBOARD WORKING DESCRIPTION AND PROGRAMMING
More informationFilm Capacitors Power Factor Correction
Film Capacitors Power Factor Correction Series/Type: Ordering code: B44066R4 R240 Date: 2 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
More informationESTAmat PFC-N. Power Factor Correction Controller. Operating Instruction MV1181. Document number: Rev. 02
Vishay Electronic GmbH Hofmark-Aich-Str.36 D-84030 Landshut Telefon +49 871 86-0 www.vishay.com Document number: 13157 - Rev. 02 Power Factor Correction Controller ESTAmat PFC-N Operating Instruction MV1181
More informationALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationClassification Enclosure rating Contact form Contact material
PCB Relay Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kv Clearance and creepage distance: 10 mm.
More informationRISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:
(With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network
More informationEIB/KNX Switch Actuators. User manual
EIB/KNX Switch Actuators User manual IT KNT 004 IT KNT 012 Tel.: +34943627988 E-mail: knx@dinuy.com Web: www.dinuy.com Contents 1. Introduction --------------------------------------------------------------------------------------------------------------
More informationMV network design & devices selection EXERCISE BOOK
MV network design & devices selection EXERCISE BOOK EXERCISES 01 - MV substation architectures 02 - MV substation architectures 03 - Industrial C13-200 MV substation 04 - Max. distance between surge arrester
More informationTechnical Data Sheet AMIK 300 / 301
USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important
More information