BENEFITS. DKD certified calibration of measuring channels available.
|
|
- Alicia Dana Barber
- 5 years ago
- Views:
Transcription
1 HiAS 743 System Capturing the complete impulse enables to obtain information about the test object faster and in more detail. HiAS 743 is the tool, which utilizes latest technology high amplitude and fast time resolution to perform this task. The HiAS 743 is a multi-channel precision digital impulse analyzing system of the highest performance class. Measurement evaluation and analysis of impulse voltages and currents can be performed according to IEC 61083, IEC 60060, IEC 60076, IEC 60099, and IEC 60230, the relevant standards for High Voltage Impulse Testing. Automatic evaluation of the impulse shapes specified in the above standards, as well as a manual evaluation mode are available. The HiAS 743 is ready for integration in a complete impulse voltage test system. The system can be fully controlled by a host computer via standard interfaces or, to reduce interference effect, via an optical link. FEATURES Impulse voltage tests in industry are mainly used to control the quality of any high voltage equipment. Usually the test object is subjected to a fast voltage impulse. A defined impulse wave shape is applied to the test object. Changes in the wave-shape caused by the test object are used for detection of insulation faults. This procedure is commonly used for routine testing of transformers, bushings or other high voltage equipment. The HiAS 743 is an excellent and reliable tool for accurate measurement of all kinds of wave-shapes. Haefely Test AG also manufactures complete impulse voltage test systems to meet most requirements. This impulse generation capability plus impulse measurement offers a complete solution to modern testing needs. HiAS 743 incorporates many of our own experiences in the high voltage business, plus those of our customers. Since many years our R&D group continuously develops further the system software. Therefore this system has the most proven software in the market. Curve evaluation for example is based on databank containing hundreds of real curve data, measured in different environment and test setups all over the world. Compatibility to previous Impulse Analyzing Systems HiAS 743 / HiAS 742 and new control systems does save your investment. Old measurement data is not lost. HiAS 743 can be fully integrated into HAEFELY controls. The engineering team guarantees support, calibration etc. now and in the future. 12 bit real vertical resolution at 120 MS/s 128k memory point depth (for 12 bit data) Automatic evaluation of all common impulse shapes and their parameters Loaded with functionalities: Difference, Parameter Tolerance, FFT, Transfer, Coherence, Comparison, Step response, Smoothing, Advanced Evaluation and many more Fulfils IEC & IEC standards Clear documentation and reporting including, Test information, notes, grouping, etc. BENEFITS Easy, intuitive understandable and useable graphic user interface (GUI) Automatic test report generation from the integrated reporting tool with user definable layout, logo insertion, etc. Manual re-evaluation tool for all impulse parameters. Automatic hardware calibration with additional calibrator RIC422-4 (option) Easy re-calibration and system upgrade due to modular and independent hardware design. DKD certified calibration of measuring channels available. Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_HIAS743_0804_LWA.doc 1/ 7
2 APPLICATIONS testing of: Power Transformer Switchgears Surge Arrestors Research & Development National High Voltage Laboratories Universities etc. MEASUREMENT (DIGITIZING) FEATURES Real 12 bit amplitude resolution, a factor of 4 better compared to a common 10 bit system. Together with the powerful software analysis tools very detailed impulse diagnostics are possible. The effect of amplitude resolution on measurement accuracy is shown for 8, 10 and 12 bit recorders using a signal with 2 % full scale deflection. The difference between the original signal and a 12 bit recorder is negligible. Variable memory depth up to 128k data points. A maximum of 128'000 samples can be recorded. A variable memory depth allows one to choose a suitable record length and helps to avoid unnecessarily large file sizes. 120 MS/s and an analogue bandwidth of 50 MHz are more than enough to capture all impulse shapes in high voltage test labs. High frequency signal components usually have very low amplitudes. High amplitude resolution is therefore critical. The highest bandwidth limit is usually determined by the external high voltage divider higher bandwidths and sampling-rates in the digitizer create spurious higher frequency noise. Excellent linearity and low noise level. All tests of this 12 bit system achieve far better results than required by the related standards! A complete Record of Performance is provided with every measuring channel built into a system to ensure highest performance and reliability of the investment. ANALIZING FEATURES DKD certified measuring channel calibration is also available on request. Impulse shapes are analyzed automatically in full accordance with the standards. The HiAS enables activation of only those impulse shapes and parameters, which are really needed. Define user specific interface. Manual evaluation on every newly recorded or re-loaded impulse can still be performed for special cases - The best mean curve generator remains the human eye. Example of single points 120 MSPS. The software guides you through the process. E.g. if the peak point (100 %) is moved the 90 %, 50 % and 30 % points are moved automatically and the influence on all parameters is shown in real-time. Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_HIAS743_0804_LWA.doc 2/7
3 Multi-functional display. Real-curve 1, mean-curve 2, difference (mean - real), all points 3, help-points 4 and lines 5 etc. to calculate the parameters are shown in the curve display. The parameter calculation method is fully transparent. The evaluation of parameters is graphically documented what you see is what you get (WYSIWYG). The display can be zoomed, using the mouse, to resolutions where the individual data points can be seen. Transfer Function (option): advanced analysis e.g. for transformer testing. Additional information is available (paper E1-73 Malewski et al). colored curves An Online Toolbox can be opened by a single click, which gives access to all curve related functions such as: Stepped zooming back, preview printout, print curve, copy to clipboard, recalculation (auto & guided), manual evaluation, signal processing (smoothing), measurement cursors, grid normalization, grid optimization, FFT calculation, edit related curve information, add memos, save complete measurement, save window, save data as ASCII. FUNCTIONS Difference Function to subtract two wave-shapes includes auto-fitting and auto-zooming. Curves can be selected from the database or auto-calculation sequences can be defined with pass/fail output. Coherence Function (option): white curve Comparison of impulses performed at a reduced test level with those taken at full test level. This allows more sophisticated diagnostics of test objects or complete test fields. Additional information is available (paper E1-82 Malewski et al) Comparison Measurements (option; supplied with DKD certified measuring channels). Determination of the assigned scale factor, reference method: The assigned scale factor and dynamic behavior of the measuring system shall be determined by comparison with a reference system (IEC ) The linearity test: Values of the scale factor of the measuring system shall be measured at the minimum and maximum voltages (or currents) of the operating range and at three approximately equally spaced voltages or currents between these extremes. The reference method is by comparison with a reference measuring system. (IEC ) Parameter Tolerance Analysis to enter a max. limit on evaluated parameters (e.g. U pk ± 5 %). Define automated tolerance calculation sequences with pass/fail output. Sequence Function (option) enables full test sequences to be automated for applications such as distribution transformer production without system operators. The HiAS 743 REF supports comparison measurements series with all required calculations, visualization and reporting (with automated export to Excel ) Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_HIAS743_0804_LWA.doc 3/7
4 Step response evaluation. Internal measurement including random interleaved sampling (RIS) and external measurements (e.g. from a giga sample scope) can be loaded and analyzed E.g. select Shunt and enter a terminal value of 330 A/V. A measuring circuit image, the chosen input range and the correct input connector are indicated as well as the hint to use a matching resistor. Measurement & test information, user notes, grouping & sub-grouping, headers for clear documentation and reporting of saved impulses. Information can be added to a specific pulse and saved in a clear, customized data structure. ADDITIONAL FEATURES Useful items such as: loading external files (scope,.tdg, 742 data, stepdata, ASCII,.txt), impulse counter, pre-setable normalized and/or optimized scaling, hardware check information, etc. are implemented in the control software. History stack to search non-saved measurements. The last 10 complete measurements are saved in dynamic memory. For instant recall open history and click on the required pulse. Office software (option) for training or analysis. Identical software that runs without the HiAS 743 hardware enables off-line analysis on a computer out of the lab. This can also help for staff training. Cut & Paste. The HiAS 743 software runs under the Windows platform. This ensures state-of the-art performance. Pictures of measurement curves are saved as WMF (Windows Metafile) that allows cut and paste functionality between other programs such as Microsoft Word. Reporting tool enables selection and combination of any impulse measurement in the HiAS database. To assist in evaluating the correct impulse the actual measurement curve for the selected data is displayed before starting report generation. Predefined report templates can be chosen or a template can be modified to create a customer specific report layout. All standard Windows features are included. Self explanatory menus and symbols, quick access buttons, on-line help and hint texts for all functions, graphically supported dialogue boxes. Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_HIAS743_0804_LWA.doc 4/7
5 CALIBRATION & STANDARDS SYSTEM DESIGN Fully automatic calibration together with a (optional) Haefely reference impulse calibrator RIC 422. Full range IEC calibration with automatic reports, overnight without further manual operations, is possible. Amplitude deviations can be entered to provide automatic correction against a nominal standard calibrator. As a result the best achievable accuracy is obtained without any further calculation. HiAS 743 System consists of a main unit, containing the system CPU, control computer, power supplies, data storage, interfaces and 4 slots for the measuring channel inserts (digitizers). All accuracy sensitive elements are combined in one small unit per channel. Also supplied are peripheral devices printer, monitor, keyboard and mouse. Main unit and channel inserts are normally mounted in a desk console. Special shielding against EMC disturbances as well as a power supply are included. In put CH1 CH2 CH3 CH4 RIC 4 22 Re fer en c e Im pu l se Ca li bra to r I 0 C a lib ra t e d PRI NTE R Hig h -v o lt a g e ON rt ig g e r o u t p u t s Hig h Re o s l uti o nimp ul se Ana l yzin g Syste m HiAS743 Hig h-v olt a ge i npu ts 1 2 Hig h-vol ta g e in pu ts Vp k m a x 3 Hig h-vol tag e in pu ts 4 Ke e p f a n fi tl e r c l e a n. Hig h-vo lt ag e in pu ts COM 2 M ( o use ) H IGH V OLT AGE T EST 2000V pkm ax / 2/ 0 p F / 2/ 0 p F / 20pF LPT1 P ( ri nt er) LV IE EE4 88 C ( o ntr o l er) HV COM 1 O F Po we r Mo nit o r St a r S /t t o p / 20pF Ke yb oa rd Lo w-vo lt a ge i npu t L ow-vo lt a ge i np ut Rese t 1 00k / 20pF 1 5 Vp k m ax 100k / 20pF 1 5 Vp k m ax k / 2/ 0 p F Aux k/ / 20pF Au x3 Po wer sup pl y Po wer sup p ly Power su pp l y Power s upp l y Externa l tr i gge r i np ut Ex te n r al trig ge r in put Exte rnal tr ig ge r i npu t Exte rna l tr ig ge r i np ut Ke e p f a n fi tl e r c l e a n. Aux 2 Power of cr o n ti un e d efri rp o te c ti o n er p l ca e o yln w tih t h e sp ce fi ei d t yp e a dn r a ti gn o f fu se. Ma ni ta ni g or u n d il en to a v o di e el c citr a ls oh ck. Do n o tr e mo v e c o ve sr.re f re s re v ci ni g t o q u a fil ei d p e sr no n e.l < 5 0 V Sl : ope > 5 0 V L: e v e l 200V pkm ax < 5 0 V: Slo p e > 5 0 V: L e v e l 230V Ke ybo a d r 115V M a ni s F u se s : A s ol w 6.3 A sl o w 8 5 V V H z ma x A V Di g i itz e r nu it Dig i t iz e r u n it Di g i itz e r nu i t Di g i itz e r nu i t Po wer I / Ou n ti Vo tl a g e s e l e c t o r Ma i n s V V Hz Fu s e : 1 0 As l o w F o cr o n ti n u e d f ri e p or t e c t oi n er p al c e o n yl w ti h t h e sp e c fi ei d t y p e a n d ar t i gn o f fu s e. Ma i n ta ni g or u n d l ni e to a v o di e l e c t cir a l sh o c k. Do n o t er mo v e c o v e sr. Re f e r s e r v ci i n g t o q u a l fi ei d p e sr o n e.l The advantage of this modular design is that a single measuring channel insert (digitizer) can be easily pulled out and send back for re-calibration while the system works with the other channels. So there is no down time on the system due to factory re-calibration. Standards HiAS fulfils and surpasses the requirements of IEC A printed Record of Performance (for hardware) is shipped with every measuring channel IEC A printed Record of Performance (for software-algorithms) is shipped with every software package. Performance check function is integrated in the standard software as well. IEC 60060, IEC 60076, IEC 60099, IEC 60230, IEC 60517, ANSI C , IEEE Std 4 - Based on these standards the complex parameter evaluation software of the HiAS has been developed. Easy re-calibration: Pull out, send and receive back a measuring channel insert. Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_HIAS743_0804_LWA.doc 5/ 7
6 TECHNICAL SPECIFICATIONS System Number of channels Printer Laser printer black & white; Color laser printer optional Monitor Desktop TFT flatscreen 19 System controller (build-in) PentiumIII, 256 MB RAM Internal operating system Windows XP (Office Software package runs under: Windows 98, 2000, XP) Analogue Part High voltage input Low voltage input Connections LEMO (RA4250) BNC Input divider 1 : : 1 Input voltages 100 Vpp Vpp 640 mvpp.. 11 Vpp Input ranges 14 (factor 1.26) 14 (factor 1.26) Overvoltage protection 2 kv 15 V Overvoltage tested 6 kvpp (1.2/50 µs, 10/700 µs) - Input impedance 2 MOhm // 20 pf 100 kohm // 20 pf Analogue bandwidth (-3dB) 50 MHz Triggering internal on slope or level external on slope and level Data Acquisition / AD-Conversion Amplitude resolution Sampling rate Memory depth Resulting measuring time Data Handling Real 12 bit (4096 LSB) 120 MS/s, 60 MS/s, 30 MS/s ks/s max. 128k data points (with 12 bit resolution) 220 µs, 450 µs, 900 µs, 280 ms Internal data exchange buffered AT-BUS Storage medium Floppy 1.44 MByte, 3.5" Harddisk 40 GByte CD RW Drive Remote control RS232, (optional optical converter) On request Ethernet, IEEE488 Operating Conditions Supply voltage 100 / 115 / 230 V Temperature range C (Laser printer C ) Relative Humidity % Warm up time 35 minutes Mechanical Dimensions * 157 x 70 x 77.5 cm ( 62 x 28 x 31 ) Weight * Approx. 150 kg ( 330 lbs ) * including table and rack Overall Uncertainty Full and chopped impulses (SI, LI) Front chopped impulses (LIchopped) All time parameters (T1, Tp, Tc, T2, etc.) Standards ± 1 % U Peak ± 1 % U Peak ± 2 % in time Fulfils or surpasses the requirements of IEC , IEC and IEC Record of Performance Full IEC and IEC record of performance are supplied with every system respectively channel insert Calibration Fully automatic (with optional Reference Impulse Calibrator RIC 422-4, controlled by HiAS software) Certification DKD (Deutscher Kalibrierdienst) calibration and certification of measuring channel inserts optional available Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_HIAS743_0804_LWA.doc 6/7
7 Re fer en c e Im pu l se Ca li bra to r St a r t/st o p H IGH V OLT AGE T EST Po we r Hig h -v o lt a g e C a lib ra t e d O F ON Tr ig g e r o u t p u t s HV L V RIC 4 22 Hig h Re so l uti o n Imp ul se Ana l yzi n g Syste m HiAS 743 Rese t Power Ke ybo a rd Hig h-v olta ge i npu ts V p k m a x 0 I 2 M / /2 0 p F Po wer sup pl y k / 2 0 p F Externa l tri gge r i np ut < 5 0 V :Sl o p e > 5 0 V :L e v e l Di g i tiz e r un it 1 Hig h-vol ta g e in pu ts Vp k m a x 2 M / /2 0 p F Lo w-vo lta ge i npu t Po wer sup p ly k / 2 0 p F Ex te rn al trig ge rin put V p k m a x < 5 0 V: Slo p e Dig i t iz e r u n it CH1 CH2 CH3 CH4 2 Hig h-vol tag e in pu ts 2 M / 2 0 p F L ow-vo lta ge i np ut Power su pp l y k / /2 0 p F Exte rnal trig ge ri npu t Di g i tiz e r un i t 3 In put Hig h-vo ltag e in pu ts Di g i tiz e 2 M / 2 0 p F Power s upp l y k / / 2 0 p F Exte rna l trig ge r i np ut > 5 0 V: L e v e l r un i t 4 I / O u n it Ke e p f a n fi lt e r c l e a n. Ke e p f a n fi lt e r c l e a n. Au x 3 PRINTER Vo lt a g e s e l e c t o r IEEE4 88 (Co ntro l er) COM 2 (Mo use ) Aux 1 Fo rc o n ti nu e d fire pr o te c ti o n re p l ac e o nly w ith t h e sp ec if ie d t yp e a nd r a ti ng o f fu se. Ma in ta in g ro u n d li ne to a v o id e le c tric a l s ho ck. Do n o tr e mo v e c o ve rs.re f er s er v ic in g t o q u a lif ie d p e rs on n e l V V M a in s F u se s : A s lo w 6.3 A sl o w 8 5 V V H z ma x VA Aux 2 COM 1 Mo nito r F o rc o n ti n u e d f ir e p ro t e c t io n re p la c e o n ly w it h t h e sp e c if ie d t y p e a n d ra t i ng o f fu s e. Ma i n ta in g ro u n d l in e to a v o id e l e c t ric a l sh o c k. Do n o t re mo v e c o v e rs. Re f e r s e r v ic i n g t o q u a l if ie d p e rs o n e l. Ma i n s V V Hz F u s e : LPT 1 (Pri nter) Po wer 1 0 A s l o w Ke yb oa rd SCOPE OF SUPPLY E.g. HIAS 743-4; HS RIC (4 channel system, mounted in a minirack with desk and built-in RIC422-4 calibrator) Qty. 1 Desk with mini-rack, main switch, grounding connections, cables Qty. 1 HiAS 743 mainframe unit with system CPU, supplies, CD RW, Floppy, HDD, channel slots, Interfaces. Qty. 4 Measuring channel insert (Digitizer) including Record of performance. Qty. 4 75Ω LEMO termination resistor Qty. 1 Mouse, ASCII keyboard Qty. 1 Flatscreen, TFT monitor, 19 Qty. 1 Laserprinter, 1200dpi Qty. 1 Set of software backup disks Qty. 2 All operating manuals (English) Qty. 1 RIC with all connection cables, built into rack. Including Manual, certificate, correction floppy. ORDERING INFORMATION System System, minirack & desk, 1 channel System, minirack & desk, 2 channels System, minirack & desk, 3 channels System, minirack & desk, 4 channels System, minirack & desk, 2 DKD certified Reference channels, Comparison Test software package (SW option COMP, MS Excel, prepared calculation sheets) HIAS HIAS HIAS HIAS HIAS REF Options Desktop housing instead of desk and rack ( price reduction; 2 channels max.) HS 743 DT upgrade (1 additional measuring channel insert ) HS 743 CHANNEL upgrade (1 additional DKD certified Reference measuring channel insert ) HS 743 CHANNEL DKD Sequence recorder software tool HS 743 SEQ Interfacing software package to allow remote controlling the HiAS, e.g. from a host PC over RS232 HS 743 REMOTE Transfer Function software tool HS 743 TF Transfer Function & Coherence Function software tool HS 743 CTF Office Software (OS: Win98, 2000, XP) HS 743 OFFICE Software Upgrade Package ( upgrade older HIAS mainframes (Pentium III required) to the newest software package) HS 743 SW UP Accessories Reference Impulse Calibrator, 4 channels, IEEE488 & RS232 interface HS RIC European Contact Haefely Test AG Lehenmattstrasse Basel Switzerland sales@haefely.com Locate your local sales representative at USA Contact Hipotronics Inc Route 22 PO Box 414 Brewster, NY USA sales@hipotronics.com Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. LL_HIAS743_0804_LWA.doc 7/7
HiAS TM 744 HIGHEST RESOLUTION IMPULSE ANALYZING SYSTEM
HiAS TM 744 HIGHEST RESOLUTION IMPULSE ANALYZING SYSTEM reliable. precision. HIGH V O L T A G E T E S T S OLUTION S 2 Impulse Analyzer IMPULSE ANALYZER Application Dielectric tests with impulse voltage
More informationKIT 4.0 HIGH VOLTAGE CONSTRUCTION KIT. reliable. precision. HIGH V O L T A G E T E S T S OLUTION S
KIT 4.0 HIGH VOLTAGE CONSTRUCTION KIT reliable. precision. HIGH V O L T A G E T E S T S OLUTION S 2 General Description GENERAL DESCRIPTION APPLICATION The KIT 4.0 is a high voltage system made of easily
More informationWaveStation Function/Arbitrary Waveform Generators
WaveStation Function/Arbitrary Waveform Generators Key Features High performance with 14-bit, 125 MS/s and 16 kpts 2 channels on all models Large 3.5 color display for easy waveform preview Over 40 built-in
More informationWaveStation Function/Arbitrary Waveform Generators
Function/Arbitrary Waveform Generators Key Features High performance with 14-bit waveform generation, up to 500 MS/s sample rate and up to 512 kpts memory 2 channels on all models Large color display for
More informationMIDAS Mobile Insulation Diagnosis & Analysing System. Features. Benefits. Applications
MIDAS 2880 Mobile Insulation Diagnosis & Analysing System Periodic maintenance and inspection of high voltage insulation losses is performed on power transformers, bushings, motors, generators, etc. The
More informationWaveStation Function/Arbitrary Waveform Generators
WaveStation Function/Arbitrary Waveform Generators Key Features High performance with 14-bit, 125 MS/s and 16 kpts 2 channels on all models Large 3.5 color display for easy waveform preview Over 40 built-in
More informationDivide. MHz models) waveform record
The 2550 series digital storage oscilloscopes provide high performance and value in 2-channel and 4-channel configurations. With bandwidth from 70 MHz to 300 MHz and 2 GSa/s sample rates, these oscilloscopes
More informationAC Dielectric Test Sets
AC Dielectric Test Sets AC Test Systems Hipotronics standard line of AC Test Systems are designed to perform high voltage AC tests on electrical apparatus in accordance with IEC60, IEEE 4 and IEC 270 and
More informationSpectrum Analyzer R&S FS300
Spectrum Analyzer R&S FS300 9 khz to 3 GHz The new product family from Rohde & Schwarz Professional test equipment for laboratory, service and production The R&S FS300 is a highly accurate spectrum analyzer
More informationTMS 580. Transformer Loss Measuring System FEATURES BENEFITS APPLICATIONS
TMS 580 Transformer Loss Measuring System The measurement of the losses in power transformers is an indispensable quality-verification process. Due to the fact that normally the transformer user puts a
More informationModular Partial Discharge (PD) & Radio Interference Voltage (RIV) Detector
DDX 9121b Modular Partial Discharge (PD) & Radio Interference Voltage (RIV) Detector The DDX 9121b is the latest in the DDX family of partial discharge & radio interference voltage testing instruments.
More informationTransient Data Acquisition System, TAS 4-40 Potential-free measurement of fast rise pulses:
Transient Data Acquisition System, TAS 4-40 Potential-free measurement of fast rise pulses: High precision measurement of fast rising voltages and currents causes considerable problems in many spheres
More informationNSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter
The, successor of the NSG 070, is a multifunctional EMC immunity test system. Its large frequency range from to G and its modular set-up using internal or external amplifiers enable a large variety of
More informationTechnical Specification
LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification No. E-MIG0603IN2.doc revised: 20.October 2004 1 MIG Tester Type MIG0603IN2 1 MIG Tester Type MIG0603IN2 1 1.1 Introduction 1 2
More information2-channel models. 4-channel models
2-channel models DSO1052B DSO1072B DSO1102B DSO1152B 50 MHz 70 MHz 100 MHz 150 MHz 4-channel models DSO1004A DSO1014A DSO1024A 60 MHz 100 MHz 200 MHz DSO1022A 200 MHz Segment 1 Segment 2 Segment 1000
More information700 Series AC Dielectric Test Sets
700 Series AC Dielectric Test Sets AC Test Systems HAEFELY HIPOTRONICS standard line of AC Dielectric Test Systems is designed to perform high voltage AC tests on electrical apparatus in accordance with
More informationTesT system for ConduCTed and radiated immunity
nsg 070 TesT system for ConduCTed and radiated immunity The, successor of the NSG 070, is a multifunctional EMC immunity test system. Its large frequency range from to G and its modular set-up using internal
More informationAutomatic Transformer Winding Analyser
2293 Automatic Transformer Winding Analyser The 2293 is an automatic winding analyser, optimized for three phase power and distribution transformer measurements. It uniquely combines winding resistance
More information8558A 8 1/2 Digit Multimeter
8558A 8 1/2 Digit Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks
More informationBurst mode - This is incorporated to simulate simultaneous analog input. Compatible with a range of Application Development Environments
Agilent U2300A Series USB Modular Multifunction Data Acquisition(DAQ) Devices Data Sheet Features Up to 3 MSa/s sampling rate for a single channel Functions as a standalone or modular unit Easy to use
More informationAgilent Technologies 3000 Series Oscilloscopes
Agilent Technologies 3000 Series Oscilloscopes Data Sheet Full-featured oscilloscopes for the smallest budgets Features: 60 to 200 MHz bandwidths 1 GSa/s maximum sample rate Large 15-cm (5.7-in) color
More informationExperiment A8 Electronics III Procedure
Experiment A8 Electronics III Procedure Deliverables: checked lab notebook, plots Overview Electronics have come a long way in the last century. Using modern fabrication techniques, engineers can now print
More informationMODEL INFORMATION. AccuLoss MODELS ALMS 2100, ALMS 4100, ALMS 4200, ALMS 6200 & ALMS 4300
AccuLoss MODELS ALMS 2100, ALMS 4100, ALMS 4200, ALMS 6200 & ALMS 4300 The measurement of electric power and energy at high voltages and currents at low power factors is becoming increasingly important
More informationSignal Input and Trigger
Signal Input and Trigger Number of input channels 2 (CH A and CH B) Input coupling Input connector DC/AC BNC connector Input impedance 50Ω/1 MΩ, 23pF (typical value *1 ) Frequency characteristics When
More informationAgilent U2701A and U2702A USB Modular Oscilloscope. Data Sheet
Agilent U2701A and U2702A USB Modular Oscilloscope Data Sheet Features 100 MHz and 200 MHz bandwidths Up to 1GSa/s maximum sample rate 32 Mpts of waveform memory Compact and portable size 117.00 mm x 180.00
More informationNI DAQPad -6020E Family Specifications
NI DAQPad -6020E Family Specifications This document lists the I/O terminal summary and specifications for the NI DAQPad-6020E family of devices. This family includes the following devices: NI DAQPad-6020E
More informationCharge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...
Electronics & Software Charge Meter Type 5015A... Universally Applicable for Piezoelectric Measuring Technology This instrument can be used wherever mechanical quantities are measured with piezoelectric
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) R3000 EMI TEST RECEIVERS Fully IF digital EMI Receivers family for measurement of electromagnetic interference from
More informationTrue RMS Bench Multimeter 5492B
Data Sheet True RMS Bench Multimeter 5492B True RMS Bench Multimeter The B&K Precision model 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service
More informationAgilent Technologies 3000 Series Oscilloscopes
Agilent Technologies 3000 Series Oscilloscopes Data Sheet Full-featured oscilloscopes for the smallest budgets Features: 60 to 200 MHz bandwidths 1 GSa/s maximum sample rate Large 15-cm (5.7-in) color
More informationDual Channel Function/Arbitrary Waveform Generators 4050B Series
Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/ Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary
More informationDual Channel Function/Arbitrary Waveform Generators 4050 Series
Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary
More informationFRAX Series Sweep Frequency Response Analyzers
FRAX Series Highest dynamic range and accuracy in the industry Fulfills international standards for SFRA measurements Advanced analysis and decision support built into the software Imports data from other
More informationFully automated three phase 250V Transformer Turns Ratio Meter
TTR 2796 Fully automated three phase 250V Transformer Turns Ratio Meter FEATURES AND BENEFITS Fully automated measurement of turns ratio, voltage ratio, phase displacement, and excitation current. Better
More informationAgilent U2300A Series USB Modular Multifunction Data-Acquisition Devices
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Agilent U2356A Product Page Agilent U2300A Series USB Modular Multifunction
More informationWaveAce 1000 and 2000 Oscilloscopes
1000 and 2000 Oscilloscopes 40 MHz 300 MHz Key Features Sample rates up to 2 GS/s 1 Mpts/ch memory, 2 Mpts interleaved 7" color display on all models 32 automatic measurements Multi-language user interface
More informationFREJA 306 Relay Testing System
Relay Testing System A Megger Group Company FREJA 306 Relay testing system FREJA 306 is the latest member of the relay testing equipment from Programma, quick and easy to use, like the FREJA 300. The rugged
More informationArbitrary/Function Generator AFG1000 Series Datasheet
Arbitrary/Function Generator AFG1000 Series Datasheet 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Compatible with TekSmartLab
More informationDIGITAL OSCILLOSCOPES & DIGITAL SCOPES
7004 Digital Oscilloscopes DL4100 (700430) 38 220 427mm 15kg ( 15-11/16 8-11/16 16-7/8" 33.1 lbs) YOKOGAWA introduces a brand new digital oscilloscope with outstanding performance. The DL4100 / DL4200
More informationVoltage Transient Emission Test
Manual For Operation AN 200 Series Voltage Transient Emission Test AN 200 AN 200B The AN 200 is used to evaluate automotive electrical and electronic components for conducted emissions of transients along
More informationTEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY
C TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY Integrated signal generator to G power meter inputs to G Integrated class A power amplifier module for different applications: W, 0 to 0 ; 0 W, 0 to 00
More informationTEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY
TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY Integrated signal generator to G power meter inputs to G Integrated class A power amplifier module for different applications: W, 0 to 0 ; 0 W, 0 to 00 ;
More information8588A Reference Multimeter
8588A Reference Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of
More informationUniversally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Instant value. Extreme values ors statistic measurements
Electronics & Software Charge Meter Universally Applicable for Piezoelectric Measuring Technology Type 5015A... This instrument can be used wherever mechanical quantities are measured with piezoelectric
More informationTrue RMS Bench Multimeter 5492B
Data Sheet 5492B T The B&K Precision model 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service repair, and manufacturing. The instrument enhances
More informationNI 6731/6733 Specifications
NI 6731/6733 Specifications This document lists the specifications for the NI 6731/6733 analog output devices. The following specifications are typical at 25 C unless otherwise noted. Note With NI-DAQmx,
More informationExperiment A8 Electronics III Procedure
Experiment A8 Electronics III Procedure Deliverables: checked lab notebook, plots Overview Electronics have come a long way in the last century. Using modern fabrication techniques, engineers can now print
More informationSpecification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters.
Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters. Scope: This specification defines the requirement of a Three
More informationModels 296 and 295 combine sophisticated
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Models 296 and 295 50 MS/s Synthesized Multichannel Arbitrary Waveform Generators Up to 4 Independent Channels 10 Standard
More informationUniversally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Extreme values ors statistic measurements
Electronics & Software Charge Meter Type 5015A... Universally Applicable for Piezoelectric Measuring Technology This instrument can be used wherever mechanical quantities are measured with piezoelectric
More informationFluke Norma 4000/5000
Fluke Norma 4000/5000 High Precision Power Analyzers Reliable, highly accurate measurements for the test & development of power electronics Technical Data Compact Fluke Norma Series power analyzers include
More informationNI 6013/6014 Family Specifications
NI 6013/6014 Family Specifications This document lists the I/O terminal summary and specifications for the NI 6013/6014 family of devices. This family includes the following devices: NI PCI-6013 NI PCI-6014
More informationR&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
More informationNI 6143 Specifications
NI 6143 Specifications This document lists the I/O terminal summary and specifications for the NI PCI/PXI-6143. For the most current edition of this document, refer to ni.com/manuals. Refer to the DAQ
More informationIdeal for high dynamic range measurements from compression to noise floor
USB/Ethernet Very Wideband Synthesized Signal Generator 5Ω -75 dbm to +14 dbm, 25 khz - 64 MHz The Big Deal Cost effective production test solution Power level resolution of.1 db Frequency resolution under.1
More informationDS1000B Series Digital Oscilloscopes
Product Overview DS1000B series oscilloscopes are designed with four analog channels and 1 external trigger channel, which can capture multi-channel signal simultaneously and meet industrial needs. The
More information500 khz / 1 MHz Precision LCR Meter Models 894 & 895
Data Sheet 500 khz / 1 MHz Precision LCR Meter Industry-Leading Performance The 894 and 895 are high accuracy LCR meters capable of measuring inductance, capacitance, and resistance of components and materials
More information2520 Pulsed Laser Diode Test System
Complete pulse test of laser diode bars and chips with dual photocurrent measurement channels 0 Pulsed Laser Diode Test System Simplifies laser diode L-I-V testing prior to packaging or active temperature
More informationReflectometer Series:
Reflectometer Series: R54, R60 & R140 Vector Network Analyzers Clarke & Severn Electronics Ph +612 9482 1944 Email sales@clarke.com.au BUY NOW - www.cseonline.com.au KEY FEATURES Patent: US 9,291,657 No
More informationPOINTAX 6000L2 Point Recorder
GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, over-current protection relays, energy meters and transducers Primary injection testing capabilities
More informationFRAX Series Sweep Frequency Response Analyzers
FRAX Series Highest dynamic range and accuracy in the industry Fulfills international standards for SFRA measurements Advanced analysis and decision support built into the software. FRAX 150 with built
More information2400C Series Microwave Signal Generators 10 MHz to 40 GHz. Preliminary Technical Datasheet. Low Phase Noise and Fast-Switching Speed in a Single Unit
Preliminary Technical Datasheet 2400C Series Microwave Signal Generators 10 MHz to 40 GHz Low Phase Noise and Fast-Switching Speed in a Single Unit 2400C Series Microwave Signal Generator Signal Generator
More informationD D X. Digital Partial Discharge Detector
D D X Digital Partial Discharge Detector You ve always heard about the best Here is the newest generation of partial discharge testing technology. The technology to get more done, more accurately, and
More informationAgilent ESA-L Series Spectrum Analyzers
Agilent ESA-L Series Spectrum Analyzers Data Sheet Available frequency ranges E4403B E4408B 9 khz to 1.5 GHz 9 khz to 3.0 GHz 9 khz to 26.5 GHz As the lowest cost ESA option, these basic analyzers are
More informationDigital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display
5 1/2 Digit DMM Series Enabling Dual Input and Display R6451A/6452A R6451A: General-Purpose Low-Price DMM with Standard Functions R6452A: Full-Functional DMM with Dual- Channel Input and Dual Display (Photo
More informationMultiple Instrument Station Module
Multiple Instrument Station Module Digital Storage Oscilloscope Vertical Channels Sampling rate Bandwidth Coupling Input impedance Vertical sensitivity Vertical resolution Max. input voltage Horizontal
More informationAgilent 33522A Function Arbitrary Waveform Generator. Tektronix TDS 3012B Oscilloscope
Agilent 33522A Function/Arbitrary Waveform Generator and Tektronix TDS 3012B Oscilloscope Agilent 33522A Function Arbitrary Waveform Generator The signal source for this lab is the Agilent 33522A Function
More informationDATA SHEET. E4982A LCR Meter. 1 MHz to 300 MHz/500 MHz/1 GHz/3 GHz
DATA SHEET E4982A LCR Meter 1 MHz to 300 MHz/500 MHz/1 GHz/3 GHz Specification (spec.) Warranted performance. All specifications apply at 23 C ± 5 C unless otherwise stated, and 30 minutes after the instrument
More informationSIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB
SYNTHESIZED SIGNAL GENERATOR MG3633A GPIB For Evaluating of Quasi-Microwaves and Measuring High-Performance Receivers The MG3633A has excellent resolution, switching speed, signal purity, and a high output
More informationSEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications
Sefram SEFRAM Make sure to visit our Website http://wwwseframfr A new family of paperless recorders 6 to 72 channels, to cover all your applications 6 to 72 analogue channels Measurement boards : - 6 isolated
More informationTektronix: Products > AWG 2040 Arbitrary Waveform Generator
Page 1 of 7 Arbitrary Waveform Generator AWG 2040 This product is no longer carried in our catalog. Features 1.024 GS/sec Clock Rate Provides up to 500 MHz Waveforms 1 MB Record Length (4 MB with Opt.
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities
More informationR&S CBT/R&S CBT32 Bluetooth Tester Specifications
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) R&S CBT/R&S CBT32 Bluetooth Tester Specifications Test & Measurement Data Sheet 06.00 CONTENTS Unit specifications...
More informationFixed head Doppler radars
Weibel Scientific Solvang 30 3450 Allerød Denmark Fixed head Doppler radars Network ready for the future 1. Introduction The network ready SL-xxxP family of fixed head Weibel Doppler Radar Systems are
More informationEMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing
EMC PARTNER DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management
More informationHigh-precision process calibrator Model CED7000
Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry
More informationCalifornia Instruments BPS Series kva V A / Phase. Overview. High Power AC Source. Expandable Power Levels.
California Instruments Overview High AC Source Expandable Levels Remote Control 30 180 kva 150 400 V 0 400 A / Phase 208 230 400 480 Introduction The consists of multiple high power AC power systems that
More informationArbitrary/Function Waveform Generators 4075B Series
Data Sheet Arbitrary/Function Waveform Generators Point-by-Point Signal Integrity The Arbitrary/Function Waveform Generators are versatile high-performance single- and dual-channel arbitrary waveform generators
More informationRIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview The DS1000E, DS1000D series instruments are economical, high-performance digital oscilloscopes.
More informationTechnical Specification
LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification E-MIG1203CWG revised: 22. June 2003 1 MIG Tester Type MIG1203CWG 1 MIG Tester Type MIG1203CWG 1 1.1 Introduction 1 2 General 2
More information5790A Automated AC Measurement Standard
5790A Automated AC Measurement Standard Technical Data Accuracy that s easy to use The 5790A is a complete automated ac measurement standard designed for the most demanding calibration applications. It
More informationTTR2796. Fully Automated Three Phase 250V Transformer Turns Ratio Meter FEATURES AND BENEFITS APPLICATIONS
TTR2796 Fully Automated Three Phase 250V Transformer Turns Ratio Meter A close collaboration with major transformer manufacturers has lead to the new HAEFELY HIPOTRONICS 2796 Transformer Turns Ratio Meter.
More informationLT224/LT322/LT342/LT344/LT364 Technical Specifications
LT224/LT322/LT342/LT344/LT364 Technical Specifications Acquisition System Bandwidth (-3dB): LT322/LT342/LT344/LT364: 500 MHz @ 50 Ohm and at probe tip with PP006; select bandwidth limit (25 or 200 MHz)
More informationModular Programmable DC Electronic Load MDL Series
Data Sheet Modular Programmable DC Electronic Load The is a multi-channel modular programmable electronic load system. Seven different modules of programmable DC loads ranging in power from 200 W to 600
More informationArbStudio Arbitrary Waveform Generators
ArbStudio Arbitrary Waveform Generators Key Features Outstanding performance with 16-bit, 1 GS/s sample rate and 2 Mpts/Ch 2 and 4 channel models Digital pattern generator PWM mode Sweep and burst modes
More informationData Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V
Agilent M9185A PXI Isolated D/A Converter Data Sheet 8/16-Channel 16-bit, ±16 V DISCOVER the Alternatives...... Agilent MODULAR Products Overview Introduction The Agilent M9185A is a digital/analog converter
More informationR&S OSP Open Switch and Control Platform Specifications
R&S OSP Open Switch and Control Platform Specifications Data Sheet Version 15.00 CONTENTS Definitions... 4 Introduction... 5 R&S OSP120... 5 R&S OSP130... 5 R&S OSP150... 5 R&S OSP-B200S2... 5 General
More information500 khz / 1 MHz Precision LCR Meter Models 894 & 895
Data Sheet 500 khz / 1 MHz Precision LCR Meter 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Industry-Leading Performance The
More informationDual Channel Function/Arbitrary Waveform Generators 4050 Series
Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary
More informationLeCroy 9304A, 9304AM Digital Oscilloscopes 200 MHz Bandwidth, 100 MS/s. Main Features
LeCroy 9304A, 9304AM Digital Oscilloscopes 200 MHz Bandwidth, 100 MS/s Main Features Four Channels 50k and 200k Point Records DOS Compatible Floppy Disk, PCMCIA portable hard drive and Memory Card Options
More informationOscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications
Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications These specifications apply to the 5520A-SC1100, 5500A-SC600 and 5500A-SC300 Oscilloscope Calibration
More informationN432A Thermistor Power Meter DATA SHEET
N432A Thermistor Power Meter DATA SHEET Why Keysight s Power Meters and Sensors? Keysight s only power meter that supports thermistor mount with useful enhancements for metrology and calibration lab environments.
More informationAgilent ENA Series 2, 3 and 4 Port RF Network Analyzers E5070A 300 khz to 3 GHz E5071A 300 khz to 8.5 GHz E5091A Multiport Test Set.
Agilent ENA Series 2, 3 and 4 Port RF Network Analyzers E5070A 300 khz to 3 GHz E5071A 300 khz to 8.5 GHz E5091A Multiport Test Set Data Sheet Definitions All specifications apply over a 5 C to 40 C range
More informationSefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website
Make sure to visit our Website http://wwwseframfr Sefram Sefram SEFRAM A new family of thermal recorders 6 to 36 channels 6 to 36 analogue channels Measurement boards : - 6 isolated channels universal
More information2601 System SourceMeter 2602 Multi-Channel I-V Test Solutions
601 System SourceMeter 60 Multi-Channel I-V Test Solutions SPECIFICATION CONDITIONS This document contains specifications and supplemental information for the Models 601 and 60. Specifications are the
More informationPortable Multi-Channel Recorder Model DAS240-BAT
Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes
More informationR3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation
R3477 Signal Analyzers Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation Frequency range: 9 khz to 13.5 GHz World
More informationR&S OSP Open Switch and Control Platform Specifications
R&S OSP Open Switch and Control Platform Specifications Data Sheet Version 18.00 CONTENTS Definitions... 4 Introduction... 5 R&S OSP120... 5 R&S OSP130... 5 R&S OSP150... 5 R&S OSP-B200S2... 5 General
More informationPhase Matrix, Inc. 545B 548B. Phase Matrix, Inc. EIP 545B and 548B CW Frequency Counters. Instruments You Can Count On
Phase Matrix, Inc. Instruments You Can Count On 545B 548B Phase Matrix, Inc. EIP 545B and 548B CW Frequency Counters Full Function CW Microwave Frequency Counters with Selective Power Measurement Keyboard
More information