1 Learning Objectives Understand the basic operation of CROP scintillation counters and photomultiplier tubes (PMTs) and their use in measuring cosmic ray air showers Understand how light is generated in a scintillator Understand how light is transmitted to a PMT Understand how a PMT generates an electric signal Be able to hook up a scintillation counter to its high voltage and an oscilloscope for viewing signals Be able to identify light leaks in a scintillation counter Be able to observe scintillation counter signals using an oscilloscope and identify cosmic ray muons Be able to discuss scintillation counter performance in terms of gain, efficiency and attenuation length

2 Outline Introduction Light Generation in Scintillators Light Collection Optical Interfaces and Connections Photodetectors and photomultiplier tubes Performance and Exercises References

3 Introduction Scintillation counters are multi-purpose particle detectors used in many experimental physics applications Used for charged particle detection (positive or negative), but also neutral particles (photons, neutrons), although light-generation mechanisms are different for charged and neutral particles Basic sequence -- light generation by particle passing through scintillator material, light collection, photodetector turns light into electric signal Scintillation Counter Properties Fast time response -- light generated almost immediately after particle passes through scintillator, photodetectors give fast electric signal Can count number of particles using pulse height. The larger the signal size, the greater the number of particles Position information Based on size of active scintillator material

4 Basic principles of operation Passage of charged particle generates light in scintillator Charged particle Light guide transmits light to photodetector Photomultiplier tube (PM or PMT) generates electric signal

5 Introduction Examples from High Energy Physics experiments at particle accelerators Hodoscope -- an array of several counters covering a large area Veto counters -- for particles you don t want to measure Calorimetry -- measuring a particle s total energy Triggering -- a fast signal which indicates an interesting event to record Examples from cosmic ray experiments CASA KASCADE

6 Scintillation counters in High-Energy Physics Experiments Fermilab, Batavia, Illinois Protons Anti-protons 1m CERN, Geneva, Switzerland

7 Scintillation counter hodoscope Photomultiplier tube Scintillator wedge Foil wrapping Counters arranged as pizza slices

8 Chicago Air Shower Array (CASA) Dugway Proving Grounds, Utah University of Chicago and University of Utah collaboration to study extended cosmic ray air showers 1089 boxes in a rectangular grid, 15 meter spacing, each with 4 scintillator planes and 4 photomultplier tubes 1 low voltage and 1 high voltage supply 1 electronics card for data triggering and data acquisition CASA collected data in the 1990 s and is now complete CROP will use retired scintillation counters recovered from CASA

9 Contents of a CASA detector station Weatherproof box top Electronics card 4 scintillators and PMTs Box bottom

10 The KASCADE experiment in Karlsruhe, Germany KASCADE = KArlsruhe Shower Core and Array DEtector 252 detector stations Rectangular grid with 13 m spacing Array of 200 x 200 m 2

11 The KASCADE experiment

12 Introduction Other uses of scintillation counters -- biological research, medical applications (PET scans) Use of scintillation counters in CROP Several counters firing at once indicates extended air shower -- on one school or inter-school Pulse heights related to number of particles in shower and energy of primary cosmic ray Relative arrival times related to primary cosmic ray incident direction

13 PET Scans (Positron Emission Tomography) Scintillating crystal detector and photomultiplier 3-D image Cross Section

14 2. Light generation in scintillators Different scintillator materials Plastic scintillator -- good for large areas Sodium Iodide (NaI) BGO (Bi 4 Ge 2 O 12 ) Inorganic crystals Lead Tungstanate (PbWO 4 ) Focus on plastic scintillator Composition Polystyrene (plexiglass) Doped with small admixture of a fluor Fluor is organic macro-molecule like POPOP: 1,4-Bis-[2-(5-phenyloxazolyl)]-benzene C 24 H 16 N 2 O 2 Light generated by fluorescence process One of energy loss mechanisms when charged particles pass through matter Similar to television screen or computer monitor Quantum mechanical process Light (photons) emitted isotropically Emission spectrum from typical scintillator Relation to visible light spectrum

15 Energy absorption and emission diagram Electrons excited to higher energy levels when a charged particle passes, absorbing part of its energy Electron ground state Electrons drop back to ground state, emitting fluorescence or scintillation light

16 Typical plastic scintillator emission spectrum Wavelength of emitted light 1 nm = 1 nanometer = meter For reference, 1 nm = 10 Angstroms, where 1 Angstrom is approximate size of an atom Maximum emission at about 425 nm

17 The wavelengths of visible light

18

19 3. Light Collection Purpose -- Direct as much generated light as possible to the photodetector Need for making counters light tight Light transmission within scintillator Reflections from surfaces, total internal reflection Transmission through surfaces Critical angle Importance of smooth polished surfaces Use of reflective coverings (foil, white paint, white paper, black paper) Multiple bounces (many!) Ray-tracing simulation programs Attenuation of light in scintillator

20 Light transmission within scintillator Charged particle passes through here Scintillator Light rays Photomultiplier tubes

21 Reflection and transmission at surfaces Air Scintillator material Light totally internally reflected for incident angle greater than Θ critical which depends on optical properties of scintillator and air Scintillator Air Refraction (i.e. transmission) outside scintillator for incident angle less than Θ critical

22 3. Light Collection Different light collection schemes Different types of plastic light guides Air light guides (KASCADE) CASA scheme Not optimal, PMT glued onto surface Wavelength-shifting side bars Embedded wavelength-shifting optical fibers Connected to clear optical fibers Can transport light over long distance Other fiber optics applications Laproscopic surgery Telecommunications

23 Laproscopic surgery Optical fibers transmit image to surgeon Less instrusive technique

24 Light collection in the KASCADE experiment Electron and photon detector Photomultiplier 33 kg of liquid scintillator Argon-filled space (better light transmission than air) Light emitted from scintillator is guided by conical reflecting surfaces to photomultiplier tube above

25 Light collection in the KASCADE experiment Muon detector Wavelength-shifting bars around perimeter of planes guide light to photomultiplier tubes 4 plastic scintillator planes

26 Optical Fibers Fiber core and cladding optimized to prevent leakage of light out of the fiber 95% transmission over 1 km If this were true for ocean water, you could clearly see ocean bottom Transmission modes within optical fibers

27 What s wrong with this picture? Scintillation Counters and Photomultiplier Tubes

28 Several scintillators tied together optically with optical fibers Wavelehgth-shifting optical fiber To photo-detector Scintillator planes

29 Advantages and limitations of each type of light read-out scheme Definition of efficiency of light collection Number of photons arriving at the photo-detector Number of photons generated by charged particle About 10% for light guide attached to side A few percent for CASA counters

30 4. Optical Interfaces and Connections Purpose -- transmit light with high efficiency, sometimes provide mechanical stability of detector as well (should decouple the two tasks if possible) Interface between scintillator material and Light guide Optical fiber Wavelength-shifting bar Interface between light guide or fiber and photodetector Commonly used Optical cements and epoxies Optical grease Air gap

31 5. Photodetectors and Photomultiplier Tubes Purpose -- transform light into electric signal for further processing of particle information Examples Photomultiplier tube (CROP focus) Photodiode Charged-coupled device Avalanche photodiode (APD) Visible Light Photon Counter (cryogenics) Photomultiplier tube details Entrance window Must be transparent for light wavelengths which need to enter tube Common: glass Fused silicate -- transmits ultraviolet as well

32 Schematic drawing of a photomultiplier tube (from scintillator) Photocathode Photons eject electrons via photoelectric effect Each incident electron ejects about 4 new electrons at each dynode stage Vacuum inside tube Multiplied signal comes out here An applied voltage difference between dynodes makes electrons accelerate from stage to stage

33 Different types of dynode chain geometries

34 Definition of Photomultiplier Tube Gain δ = average number of electrons generated at each dynode stage Typically, δ = 4, but this depends on dynode material and the voltage difference between dynodes n = number of multiplication stages Photomultiplier tube gain = δ n For n = 10 stages and δ = 4, gain = 4 10 = This means that one electron emitted from the photocathode (these are called photoelectrons ) yields electrons at the signal output

35 The Photocathode Incoming photons expel electrons from the metallic surface of the photocathode via the photoelectric effect. The effect was discovered by Heinrich Hertz in 1887 and explained by Albert Einstein in According to Einstein's theory, light is composed of discrete particles of energy, or quanta, called PHOTONS. When photons with enough energy strike the photocathode, they liberate electrons that have a kinetic energy equal to the energy of the photons less the work function (the energy required to free the electrons from a particular material). Einstein received the Nobel Prize for his 1905 paper explaining the photoelectric effect. What were the other two famous Einstein papers from 1905? Theory of special relativity Explanation of Brownian motion

36 The Photocathode Photocathode composition Semiconductor material made of antimony (Sb) and one or more alkalai metals (Cs, Na, K) Thin, so ejected electrons can escape Definition of photocathode quantum efficiency, η(λ) η(λ) = Number of photoelectrons released Number of incident photons (λ) on cathode Typical photocathode quantum efficiency is 10-30% Photocathode response spectrum Need for matching scintillator light output spectrum with photocathode response spectrum

37 Typical photocathode response curve 200 nm Wavelength of light 700 nm 1 nm = 1 nanometer = meter Note: Quantum efficiency > 20% in range nm Peak response for light wavelengths near 400 nm

38 The dynode chain High voltage applied to dynodes creates electric fields which guide electrons between from stage to stage Process of secondary emission yields more electrons at each stage This is the multiplication in photomultiplier Process is similar to photoelectric effect, with incident photon replaced by incident electron Composition of dynodes Ag - Mg Cu - Be Deposited in thin layer on Cs - Sb conducting support Sensitivity to earth s magnetic field Earth s magnetic field is typically Gauss Trajectories of charged particles moving in a magnetic field will curve, depending on field orientation Can cause photoelectrons and secondary-emitted electrons not to reach next stage First few stages, when there are few electrons, most vulnerable Use of magnetic shields Should extend shield beyond front of tube

39 The phototube base and high voltage supply Purpose -- provide an electric field between photocathode and first dynode successive dynodes to accelerate electrons from stage to stage About 100 V voltage difference needed between stages Chain of resistors forms voltage divider to split up high voltage into small steps Capacitors store readily-available charge for electron multiplication Typical base draws 1-2 milliamperes of current

40 The electric field between successive dynodes A simplified view Represents a dynode 100 Volts Electric field between plates Represents the next dynode An electron (negative charge) released from the negative plate will be accelerated toward the positive plate

41 Typical phototube base schematic Output signal to oscilloscope Photocathode Dynodes Tube body Ground Positive High voltage supply Capacitors (which store charge) needed for final stages when there are many electrons Output signal flows out of tube Current flows through resistor chain for voltage division

42 A simple voltage divider Current, I (amperes) 4 Ω = R 1 Greek omega for resistance unit, Ohms Battery V batt = 9 Volts Ω = R 2 a Voltmeter here b V Ohm's law : V = I R or I = R Vbatt 9 Volts Current in circuit : I = = = 1.5 Amps R1 + R2 6 Ω Vacross R 2 = I R2 = (1.5 Amps)(2 Ω) = 3 Volts Measured with voltmeter between points (a) and (b) You have divided the 9 Volt battery: 3 Volts and 6 Volts are now accessible with this circuit.

43 Vacuum inside tube body Purpose -- minimize collisions of electrons with gas molecules during transit Requires strong tube body Pins for electrical connections pierce through glass at bottom of tube (leak-tight) Damage to tube by helium or hydrogen Small gas molecules can leak into tube, even through glass

44 Variation of PMT gain with high voltage Increasing high voltage increases electron transmission efficiency from stage to stage Especially important in first 1-2 dynodes Increasing high voltage increases kinetic energy of electrons impacting dynodes Increases amplification factor δ

45 Oscilloscope traces from scintillation counters Plastic scintillator 10 nsec / division Inorganic crystal, NaI 5000 nsec / division (Longer time scale for fluorescence to occur)

46 Close-up of photoelectron trajectories to first dynode

47 References 1. Introduction to Experimental Particle Physics by Richard Fernow, Cambridge University Press, 1986, ISBN (paperback), Chapter 7, pages (includes exercises) 2. Photomultiplier Manual, Technical Series PT-61, 1970, RCA Corporation 3. Techniques for Nuclear and Particle Physics by W. R. Leo, Springer-Verlag, Germany, 1994, ISBN , Chapters 7-9, pages Radiation Detection and Measurement, 3rd Edition, by Glenn F.Knoll, Wiley 2000, ISBN , Chapters 8-10, pages

48 Light transmission through entrance wnidow Percent of light which passes Different window materials Wavelength of light 200 nm 700 nm Observe: 20% transmission typical for 400 nm light Fused silica extends transmission into lower wavelengths Less than 400 nm is ultraviolet light

49

50 6. Performance and exercises Signal shape, pulse height and duration Pulse height distributions Linearity Attenuation length Oscilloscope examples and exercises with changing high voltage, radioactive source, attenuation length

51 Development Questions Request permission to use figures now Specific figures or general release? What format to aim for this summer? Powerpoint presentation (with embedded figures?) Accompanying text Accessibility on the web, with more detail here links Curriculum & Instruction check for level-appropriateness Format for field-testing in schools

52 Slide template

Scintillation Counters

Scintillation Counters PHY311/312 Detectors for Nuclear and Particle Physics Dr. C.N. Booth Scintillation Counters Unlike many other particle detectors, which exploit the ionisation produced by the passage of a charged particle,

More information

5. Scintillation counters

5. Scintillation counters 5. Scintillation counters to detect radiation by means of scintillation is among oldest methods of particle detection historical example: particle impinging on ZnS screen -> emission of light flash principle

More information

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response (response time) 5) Stability 6) Cost 7) convenience Photoelectric

More information

5. Scintillation counters

5. Scintillation counters 5. Scintillation counters to detect radiation by means of scintillation is among oldest methods of particle detection particle impinging on ZnS screen -> emission of light flash principle of scintillation

More information

Light Collection. Plastic light guides

Light Collection. Plastic light guides Light Collection Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical signal (PMT, photodiode, ) There are several

More information

Components of Optical Instruments

Components of Optical Instruments Components of Optical Instruments General Design of Optical Instruments Sources of Radiation Wavelength Selectors (Filters, Monochromators, Interferometers) Sample Containers Radiation Transducers (Detectors)

More information

Positron Emission Tomography

Positron Emission Tomography Positron Emission Tomography UBC Physics & Astronomy / PHYS 409 1 Introduction Positron emission tomography (PET) is a non-invasive way to produce the functional 1 image of a patient. It works by injecting

More information

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland) Danube School on Instrumentation in Elementary Particle & Nuclear Physics University of Novi Sad, Serbia, September 8 th 13 th, 2014 Lab Experiment: Characterization of Silicon Photomultipliers Dominik

More information

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes HF Upgrade Studies: Characterization of Photo-Multiplier Tubes 1. Introduction Photomultiplier tubes (PMTs) are very sensitive light detectors which are commonly used in high energy physics experiments.

More information

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626 OPTI510R: Photonics Khanh Kieu College of Optical Sciences, University of Arizona kkieu@optics.arizona.edu Meinel building R.626 Photodetectors Introduction Most important characteristics Photodetector

More information

PMT Calibration in the XENON 1T Demonstrator. Abstract

PMT Calibration in the XENON 1T Demonstrator. Abstract PMT Calibration in the XENON 1T Demonstrator Sarah Vickery Nevis Laboratories, Columbia University, Irvington, NY 10533 USA (Dated: August 2, 2013) Abstract XENON Dark Matter Project searches for the dark

More information

Ph 3324 The Scintillation Detector and Gamma Ray Spectroscopy

Ph 3324 The Scintillation Detector and Gamma Ray Spectroscopy Ph 3324 The Scintillation Detector and Gamma Ray Spectroscopy Required background reading Attached are several pages from an appendix on the web for Tipler-Llewellyn Modern Physics. Read the section on

More information

OFCS OPTICAL DETECTORS 11/9/2014 LECTURES 1

OFCS OPTICAL DETECTORS 11/9/2014 LECTURES 1 OFCS OPTICAL DETECTORS 11/9/2014 LECTURES 1 1-Defintion & Mechanisms of photodetection It is a device that converts the incident light into electrical current External photoelectric effect: Electrons are

More information

Ground-based optical auroral measurements

Ground-based optical auroral measurements Ground-based optical auroral measurements FYS 3610 Background Ground-based optical measurements provides a unique way to monitor spatial and temporal variation of auroral activity at high resolution up

More information

Advanced Materials Research Vol

Advanced Materials Research Vol Advanced Materials Research Vol. 1084 (2015) pp 162-167 Submitted: 22.08.2014 (2015) Trans Tech Publications, Switzerland Revised: 13.10.2014 doi:10.4028/www.scientific.net/amr.1084.162 Accepted: 22.10.2014

More information

Chemistry 985. Some constants: q e 1.602x10 19 Coul, ɛ x10 12 F/m h 6.626x10 34 J-s, c m/s, 1 atm = 760 Torr = 101,325 Pa

Chemistry 985. Some constants: q e 1.602x10 19 Coul, ɛ x10 12 F/m h 6.626x10 34 J-s, c m/s, 1 atm = 760 Torr = 101,325 Pa Chemistry 985 Fall, 2o17 Distributed: Mon., 17 Oct. 17, 8:30AM Exam # 1 OPEN BOOK Due: 17 Oct. 17, 10:00AM Some constants: q e 1.602x10 19 Coul, ɛ 0 8.854x10 12 F/m h 6.626x10 34 J-s, c 299 792 458 m/s,

More information

1.1 The Muon Veto Detector (MUV)

1.1 The Muon Veto Detector (MUV) 1.1 The Muon Veto Detector (MUV) 1.1 The Muon Veto Detector (MUV) 1.1.1 Introduction 1.1.1.1 Physics Requirements and General Layout In addition to the straw chambers and the RICH detector, further muon

More information

Lecture 12 OPTICAL DETECTORS

Lecture 12 OPTICAL DETECTORS Lecture 12 OPTICL DETECTOS (eference: Optical Electronics in Modern Communications,. Yariv, Oxford, 1977, Ch. 11.) Photomultiplier Tube (PMT) Highly sensitive detector for light from near infrared ultraviolet

More information

Instructions for gg Coincidence with 22 Na. Overview of the Experiment

Instructions for gg Coincidence with 22 Na. Overview of the Experiment Overview of the Experiment Instructions for gg Coincidence with 22 Na 22 Na is a radioactive element that decays by converting a proton into a neutron: about 90% of the time through β + decay and about

More information

Page 1. Ground-based optical auroral measurements. Background. CCD All-sky Camera with filterwheel. Image intensifier

Page 1. Ground-based optical auroral measurements. Background. CCD All-sky Camera with filterwheel. Image intensifier Ground-based optical auroral measurements FYS 3610 Background Ground-based optical measurements provides a unique way to monitor spatial and temporal variation of auroral activity at high resolution up

More information

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26 Today s Outline - January 25, 2018 C. Segre (IIT) PHYS 570 - Spring 2018 January 25, 2018 1 / 26 Today s Outline - January 25, 2018 HW #2 C. Segre (IIT) PHYS 570 - Spring 2018 January 25, 2018 1 / 26 Today

More information

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors Nuclear Physics #1 Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors Introduction: In this experiment you will use both scintillation and semiconductor detectors to study γ- ray energy spectra. The

More information

Total Absorption Dual Readout Calorimetry R&D

Total Absorption Dual Readout Calorimetry R&D Available online at www.sciencedirect.com Physics Procedia 37 (2012 ) 309 316 TIPP 2011 - Technology and Instrumentation for Particle Physics 2011 Total Absorption Dual Readout Calorimetry R&D B. Bilki

More information

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons Due by 12:00 noon (in class) on Tuesday, Nov. 7, 2006. This is another hybrid lab/homework; please see Section 3.4 for what you

More information

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering RR Oct 2001 SS Dec 2001 MJ Oct 2009 Physics 34000 Laboratory Scattering of Photons from Electrons: Compton Scattering Objective: To measure the energy of high energy photons scattered from electrons in

More information

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation Spectroscopy in the UV and Visible: Instrumentation Typical UV-VIS instrument 1 Source - Disperser Sample (Blank) Detector Readout Monitor the relative response of the sample signal to the blank Transmittance

More information

event physics experiments

event physics experiments Comparison between large area PMTs at cryogenic temperature for neutrino and rare Andrea Falcone University of Pavia INFN Pavia event physics experiments Rare event physics experiment Various detectors

More information

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES The current multiplication mechanism offered by dynodes makes photomultiplier tubes ideal for low-light-level measurement. As explained earlier, there

More information

OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY. Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration

OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY. Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration 1 Dual Readout Method Addresses the limiting factors of the resolution

More information

ELECTROMAGNETIC WAVES AND THE EM SPECTRUM MR. BANKS 8 TH GRADE SCIENCE

ELECTROMAGNETIC WAVES AND THE EM SPECTRUM MR. BANKS 8 TH GRADE SCIENCE ELECTROMAGNETIC WAVES AND THE EM SPECTRUM MR. BANKS 8 TH GRADE SCIENCE ELECTROMAGNETIC WAVES Do not need matter to transfer energy. Made by vibrating electric charges. When an electric charge vibrates,

More information

8854 Photomultiplier. 129-mm (5-inch) Diameter, 14-stage QUANTACON TM Type Having a Bialkali Photocathode and High- Gain Gallium-Phosphide Dynodes

8854 Photomultiplier. 129-mm (5-inch) Diameter, 14-stage QUANTACON TM Type Having a Bialkali Photocathode and High- Gain Gallium-Phosphide Dynodes 8854 Photomultiplier 129-mm (5-inch) Diameter, 14-stage QUANTACON TM Type Having a Bialkali Photocathode and High- Gain Gallium-Phosphide Dynodes Extremely High Gain Gallium - Phosphide, GaP (Cs), First

More information

Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis

Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis Work supported partly by DOE, National Nuclear Security Administration

More information

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available. The equipment used share any common features regardless of the! being measured. Each will have a light source sample cell! selector We ll now look at various equipment types. Electronic detection was not

More information

Atomic and Nuclear Physics

Atomic and Nuclear Physics Atomic and Nuclear Physics Nuclear physics -spectroscopy LEYBOLD Physics Leaflets Detecting radiation with a scintillation counter Objects of the experiments Studying the scintillator pulses with an oscilloscope

More information

Scintillators as an external trigger for cathode strip chambers

Scintillators as an external trigger for cathode strip chambers Scintillators as an external trigger for cathode strip chambers J. A. Muñoz Department of Physics, Princeton University, Princeton, NJ 08544 An external trigger was set up to test cathode strip chambers

More information

Development of an innovative LSO-SiPM detector module for high-performance Positron Emission Tomography

Development of an innovative LSO-SiPM detector module for high-performance Positron Emission Tomography Development of an innovative LSO-SiPM detector module for high-performance Positron Emission Tomography Maria Leonor Trigo Franco Frazão leonorfrazao@ist.utl.pt Instituto Superior Técnico, Lisboa, Portugal

More information

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments Components of Optical Instruments Chapter 7_III UV, Visible and IR Instruments 1 Grating Monochromators Principle of operation: Diffraction Diffraction sources: grooves on a reflecting surface Fabrication:

More information

Ph 3455 The Photoelectric Effect

Ph 3455 The Photoelectric Effect Ph 3455 The Photoelectric Effect Required background reading Tipler, Llewellyn, section 3-3 Prelab Questions 1. In this experiment you will be using a mercury lamp as the source of photons. At the yellow

More information

Meshing Challenges in Simulating the Induced Currents in Vacuum Phototriode

Meshing Challenges in Simulating the Induced Currents in Vacuum Phototriode Meshing Challenges in Simulating the Induced Currents in Vacuum Phototriode S. Zahid and P. R. Hobson Electronic and Computer Engineering, Brunel University London, Uxbridge, UB8 3PH UK Introduction Vacuum

More information

Measurement of the Speed of Light in Air

Measurement of the Speed of Light in Air (revised, 2/27/01) Measurement of the Speed of Light in Air Advanced Laboratory, Physics 407 University of Wisconsin Madison, WI 53706 Abstract The speed of light is determined from a time of flight measurement

More information

On the initiation of lightning in thunderclouds (Instrumentation, Supplementary information)

On the initiation of lightning in thunderclouds (Instrumentation, Supplementary information) On the initiation of lightning in thunderclouds (Instrumentation, Supplementary information) Ashot Chilingarian 1,2, Suren Chilingaryan 1, Tigran Karapetyan 1, Lev Kozliner 1, Yeghia Khanikyants 1, Gagik

More information

The Photoelectric Effect

The Photoelectric Effect The Photoelectric Effect 1 The Photoelectric Effect Overview: The photoelectric effect is the light-induced emission of electrons from an object, in this case from a metal electrode inside a vacuum tube.

More information

PH2510 Nuclear Physics Laboratory Use of Scintillation Counters (NP5)

PH2510 Nuclear Physics Laboratory Use of Scintillation Counters (NP5) Physics Department Royal Holloway University of London PH2510 Nuclear Physics Laboratory Use of Scintillation Counters (NP5) 1. Introduction 1.1 Object of the Experiment The object of this experiment is

More information

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014 Detectors for microscopy - CCDs, APDs and PMTs Antonia Göhler Nov 2014 Detectors/Sensors in general are devices that detect events or changes in quantities (intensities) and provide a corresponding output,

More information

Absorption: in an OF, the loss of Optical power, resulting from conversion of that power into heat.

Absorption: in an OF, the loss of Optical power, resulting from conversion of that power into heat. Absorption: in an OF, the loss of Optical power, resulting from conversion of that power into heat. Scattering: The changes in direction of light confined within an OF, occurring due to imperfection in

More information

Cosmic Ray Detector Hardware

Cosmic Ray Detector Hardware Cosmic Ray Detector Hardware How it detects cosmic rays, what it measures and how to use it Matthew Jones Purdue University 2012 QuarkNet Summer Workshop 1 What are Cosmic Rays? Mostly muons down here

More information

Detecting and Suppressing Background Signal

Detecting and Suppressing Background Signal Detecting and Suppressing Background Signal Valerie Gray St. Norbert College Advisors: Dr. Michael Wiescher Freimann Professor Nuclear Physics University of Notre Dame Dr. Ed Stech Associate Professional

More information

PROCEEDINGS OF A SYMPOSIUM HELD AT THE CAVENDISH LABORATORY, CAMBRIDGE, Edited by

PROCEEDINGS OF A SYMPOSIUM HELD AT THE CAVENDISH LABORATORY, CAMBRIDGE, Edited by X - R A Y M I C R O S C O P Y A N D M I C R O R A D I O G R A P H Y PROCEEDINGS OF A SYMPOSIUM HELD AT THE CAVENDISH LABORATORY, CAMBRIDGE, 1956 Edited by V. E. COSSLETT Cavendish Laboratory, University

More information

The Light Amplifier Concept

The Light Amplifier Concept The Light Amplifier Concept Daniel Ferenc 1 Eckart Lorenz 1,2 Daniel Kranich 1 Alvin Laille 1 (1) Physics Department, University of California Davis (2) Max Planck Institute, Munich Work supported partly

More information

Cosmic Ray Muon Detection

Cosmic Ray Muon Detection Cosmic Ray Muon Detection Department of Physics and Space Sciences Florida Institute of Technology Georgia Karagiorgi Julie Slanker Advisor: Dr. M. Hohlmann Cosmic Ray Muons π + > µ + + ν µ π > µ + ν µ

More information

EXPERIMENT 3 THE PHOTOELECTRIC EFFECT

EXPERIMENT 3 THE PHOTOELECTRIC EFFECT EXPERIMENT 3 THE PHOTOELECTRIC EFFECT Equipment List Included Equipment 1. Mercury Light Source Enclosure 2. Track, 60 cm 3. Photodiode Enclosure 4. Mercury Light Source Power Supply 5. DC Current Amplifier

More information

Gamma Spectrometer Initial Project Proposal

Gamma Spectrometer Initial Project Proposal Gamma Spectrometer Initial Project Proposal Group 9 Aman Kataria Johnny Klarenbeek Dean Sullivan David Valentine Introduction There are currently two main types of gamma radiation detectors used for gamma

More information

Radiation detectors Photographic detection

Radiation detectors Photographic detection 10.3.2.3 Radiation detectors 10.3.2.3.1 Photographic detection Photographic detection and photographic intensity measurement are not included in this edition of the compendium. IUPAC nomenclature on this

More information

Advancement in development of photomultipliers dedicated to new scintillators studies.

Advancement in development of photomultipliers dedicated to new scintillators studies. Advancement in development of photomultipliers dedicated to new scintillators studies. Maciej Kapusta, Pascal Lavoutea, Florence Lherbet, Cyril Moussant, Paul Hink INTRODUCTION AND OUTLINE In the validation

More information

STUDY OF NEW FNAL-NICADD EXTRUDED SCINTILLATOR AS ACTIVE MEDIA OF LARGE EMCAL OF ALICE AT LHC

STUDY OF NEW FNAL-NICADD EXTRUDED SCINTILLATOR AS ACTIVE MEDIA OF LARGE EMCAL OF ALICE AT LHC STUDY OF NEW FNAL-NICADD EXTRUDED SCINTILLATOR AS ACTIVE MEDIA OF LARGE EMCAL OF ALICE AT LHC O. A. GRACHOV Department of Physics and Astronomy, Wayne State University, Detroit, MI 48201, USA T.M.CORMIER

More information

Chemistry Instrumental Analysis Lecture 7. Chem 4631

Chemistry Instrumental Analysis Lecture 7. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 7 UV to IR Components of Optical Basic components of spectroscopic instruments: stable source of radiant energy transparent container to hold sample device

More information

Photoelectric effect

Photoelectric effect Photoelectric effect Objective Study photoelectric effect. Measuring and Calculating Planck s constant, h. Measuring Current-Voltage Characteristics of photoelectric Spectral Lines. Theory Experiments

More information

CHAPTER 11 HPD (Hybrid Photo-Detector)

CHAPTER 11 HPD (Hybrid Photo-Detector) CHAPTER 11 HPD (Hybrid Photo-Detector) HPD (Hybrid Photo-Detector) is a completely new photomultiplier tube that incorporates a semiconductor element in an evacuated electron tube. In HPD operation, photoelectrons

More information

Attenuation length in strip scintillators. Jonathan Button, William McGrew, Y.-W. Lui, D. H. Youngblood

Attenuation length in strip scintillators. Jonathan Button, William McGrew, Y.-W. Lui, D. H. Youngblood Attenuation length in strip scintillators Jonathan Button, William McGrew, Y.-W. Lui, D. H. Youngblood I. Introduction The ΔE-ΔE-E decay detector as described in [1] is composed of thin strip scintillators,

More information

Explain what is meant by a photon and state one of its main properties [2]

Explain what is meant by a photon and state one of its main properties [2] 1 (a) A patient has an X-ray scan taken in hospital. The high-energy X-ray photons interact with the atoms inside the body of the patient. Explain what is meant by a photon and state one of its main properties....

More information

Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors

Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors F. Muheim a edin]department of Physics and Astronomy, University of Edinburgh Mayfield Road, Edinburgh EH9 3JZ,

More information

NAME.. Index No Candidate s Signature... Date... 2 Hours NYANDARUA WEST CLUSTER EVALUATION

NAME.. Index No Candidate s Signature... Date... 2 Hours NYANDARUA WEST CLUSTER EVALUATION NAME.. Index No Candidate s Signature... Date..... 232/2 PHYSICS PAPER 2 (THEORY) July/August 2018 2 Hours NYANDARUA WEST CLUSTER EVALUATION - 2018 Instructions to Candidates - Write your name and index

More information

The MoNA Project. Module Assembly and Testing Manual. Version 1.0 June 21, B. Luther T. Baumann

The MoNA Project. Module Assembly and Testing Manual. Version 1.0 June 21, B. Luther T. Baumann The MoNA Project Module Assembly and Testing Manual Version 1.0 June 21, 2002 B. Luther T. Baumann Outline 1 The MoNA Project 1.1 Nuclear Physics at the Neutron Drip-Line 1.2 The National Superconducting

More information

MWPC Gas Gain with Argon-CO 2 80:20 Gas Mixture

MWPC Gas Gain with Argon-CO 2 80:20 Gas Mixture IMA Journal of Mathematical Control and Information Page 1 of 10 doi:10.1093/imamci/dri000 1. Principles of Operation MWPC Gas Gain with Argon-CO 2 80:20 Gas Mixture Michael Roberts A multi-wire proportional

More information

LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points

LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points WRITE ON SCANTRON WITH NUMBER 2 PENCIL DO NOT WRITE ON THIS TEST LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points Multiple Choice Identify the choice that best completes the statement or

More information

Development of New Large-Area Photosensors in the USA

Development of New Large-Area Photosensors in the USA Development of New Large-Area Photosensors in the USA @BURLE classical PMTs (separate talk) @UC Davis: (1) ReFerence Flat Panels for mass production (2) Light Amplifiers (flat and spherical) Daniel Ferenc

More information

Summer Student project report

Summer Student project report Summer Student project report Mika Väänänen September 1, 2017 Abstract In this report I give a brief overview of my activities during the summer student project. I worked on the scintillating fibre (SciFi)

More information

Characterization of Silicon Photomultipliers and their Application to Positron Emission Tomography. Zhiwei Yang. Abstract

Characterization of Silicon Photomultipliers and their Application to Positron Emission Tomography. Zhiwei Yang. Abstract DESY Summer Student Program 2009 Report No. Characterization of Silicon Photomultipliers and their Application to Positron Emission Tomography Zhiwei Yang V. N. Karazin Kharkiv National University E-mail:

More information

Basic Components of Spectroscopic. Instrumentation

Basic Components of Spectroscopic. Instrumentation Basic Components of Spectroscopic Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh 11451 Saudi Arabia

More information

ORTEC. Research Applications. Pulse-Height, Charge, or Energy Spectroscopy. Detectors. Processing Electronics

ORTEC. Research Applications. Pulse-Height, Charge, or Energy Spectroscopy. Detectors. Processing Electronics ORTEC Spectroscopy systems for ORTEC instrumentation produce pulse height distributions of gamma ray or alpha energies. MAESTRO-32 (model A65-B32) is the software included with most spectroscopy systems

More information

6.014 Recitation 1: Wireless Radio and Optical Links

6.014 Recitation 1: Wireless Radio and Optical Links 6.014 Recitation 1: Wireless Radio and Optical Links A. Review Wireless radio links were introduced in Lecture 1. The basic equations introduced there are repeated in Figure R1-1 and below. First is the

More information

Photonics in Particle Physics

Photonics in Particle Physics Photonics in Particle Physics Prof. Peter R Hobson C.Phys M.Inst.P. School of Engineering and Design Brunel University, Uxbridge Updated December 2014 Peter.Hobson@brunel.ac.uk What is Photonics The technology

More information

Experiment 10. The Speed of Light c Introduction Apparatus

Experiment 10. The Speed of Light c Introduction Apparatus Experiment 10 The Speed of Light c 10.1 Introduction In this experiment you will measure the speed of light, c. This is one of the most fundamental constants in physics, and at the same time the fastest

More information

Infrared Detectors an overview

Infrared Detectors an overview Infrared Detectors an overview Mariangela Cestelli Guidi Sinbad IR beamline @ DaFne EDIT 2015, October 22 Frederick William Herschel (1738 1822) was born in Hanover, Germany but emigrated to Britain at

More information

SECONDARY ELECTRON DETECTION

SECONDARY ELECTRON DETECTION SECONDARY ELECTRON DETECTION CAMTEC Workshop Presentation Haitian Xu June 14 th 2010 Introduction SEM Raster scan specimen surface with focused high energy e- beam Signal produced by beam interaction with

More information

LEP Optical pumping

LEP Optical pumping Related topics Spontaeous emission, induced emission, mean lifetime of a metastable state, relaxation, inversion, diode laser. Principle and task The visible light of a semiconductor diode laser is used

More information

Electronic Instrumentation for Radiation Detection Systems

Electronic Instrumentation for Radiation Detection Systems Electronic Instrumentation for Radiation Detection Systems January 23, 2018 Joshua W. Cates, Ph.D. and Craig S. Levin, Ph.D. Course Outline Lecture Overview Brief Review of Radiation Detectors Detector

More information

Physics 342 Laboratory. Scattering of Photons from Free Electrons: Compton Scattering

Physics 342 Laboratory. Scattering of Photons from Free Electrons: Compton Scattering RR Oct 2001 SS Dec 2001 Physics 342 Laboratory Scattering of Photons from Free Electrons: Compton Scattering Objective: To measure the energy of high energy photons scattered from electrons in a brass

More information

LECTURE 20 ELECTROMAGNETIC WAVES. Instructor: Kazumi Tolich

LECTURE 20 ELECTROMAGNETIC WAVES. Instructor: Kazumi Tolich LECTURE 20 ELECTROMAGNETIC WAVES Instructor: Kazumi Tolich Lecture 20 2 25.6 The photon model of electromagnetic waves 25.7 The electromagnetic spectrum Radio waves and microwaves Infrared, visible light,

More information

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002 PET Detectors William W. Moses Lawrence Berkeley National Laboratory March 26, 2002 Step 1: Inject Patient with Radioactive Drug Drug is labeled with positron (β + ) emitting radionuclide. Drug localizes

More information

Radiation Detection Instrumentation

Radiation Detection Instrumentation Radiation Detection Instrumentation Principles of Detection and Gas-filled Ionization Chambers Neutron Sensitive Ionization Chambers Detection of radiation is a consequence of radiation interaction with

More information

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland Available on CMS information server CMS NOTE 998/8 The Compact Muon Solenoid Experiment CMS Note Mailing address: CMS CERN, CH- GENEVA 3, Switzerland 9 December 998 Fine Mesh Photodetectors for CMS Endcap

More information

Figure 2d. Optical Through-the-Air Communications Handbook -David A. Johnson,

Figure 2d. Optical Through-the-Air Communications Handbook -David A. Johnson, onto the detector. The stray light competes with the modulated light from the distant transmitter. If the environmental light is sufficiently strong it can interfere with light from the light transmitter.

More information

Chapter 21. Alternating Current Circuits and Electromagnetic Waves

Chapter 21. Alternating Current Circuits and Electromagnetic Waves Chapter 21 Alternating Current Circuits and Electromagnetic Waves AC Circuit An AC circuit consists of a combination of circuit elements and an AC generator or source The output of an AC generator is sinusoidal

More information

Unusual Tubes. Tom Duncan, KG4CUY March 8, 2019

Unusual Tubes. Tom Duncan, KG4CUY March 8, 2019 Unusual Tubes Tom Duncan, KG4CUY March 8, 2019 Tubes On Hand GAS-FILLED HIGH-VACUUM Neon Lamp (NE-51) Cold-cathode Voltage Regulator (0B2) Hot-cathode Thyratron (884) Photomultiplier (931A) Magic Eye (1629)

More information

Photons and solid state detection

Photons and solid state detection Photons and solid state detection Photons represent discrete packets ( quanta ) of optical energy Energy is hc/! (h: Planck s constant, c: speed of light,! : wavelength) For solid state detection, photons

More information

COMPONENTS OF OPTICAL INSTRUMENTS. Chapter 7 UV, Visible and IR Instruments

COMPONENTS OF OPTICAL INSTRUMENTS. Chapter 7 UV, Visible and IR Instruments COMPONENTS OF OPTICAL INSTRUMENTS Chapter 7 UV, Visible and IR Instruments 1 Topics A. GENERAL DESIGNS B. SOURCES C. WAVELENGTH SELECTORS D. SAMPLE CONTAINERS E. RADIATION TRANSDUCERS F. SIGNAL PROCESSORS

More information

COMPONENTS OF OPTICAL INSTRUMENTS. Topics

COMPONENTS OF OPTICAL INSTRUMENTS. Topics COMPONENTS OF OPTICAL INSTRUMENTS Chapter 7 UV, Visible and IR Instruments Topics A. GENERAL DESIGNS B. SOURCES C. WAVELENGTH SELECTORS D. SAMPLE CONTAINERS E. RADIATION TRANSDUCERS F. SIGNAL PROCESSORS

More information

NM Module Section 2 6 th Edition Christian, Ch. 3

NM Module Section 2 6 th Edition Christian, Ch. 3 NM 4303 Module Section 2 6 th Edition Christian, Ch. 3 Gas Filled Chamber Voltage Gas filled chamber uses Hand held detectors cutie pie Geiger counter Dose calibrators Cutie pie Chamber voltage in Ionization

More information

Design and Simulation of N-Substrate Reverse Type Ingaasp/Inp Avalanche Photodiode

Design and Simulation of N-Substrate Reverse Type Ingaasp/Inp Avalanche Photodiode International Refereed Journal of Engineering and Science (IRJES) ISSN (Online) 2319-183X, (Print) 2319-1821 Volume 2, Issue 8 (August 2013), PP.34-39 Design and Simulation of N-Substrate Reverse Type

More information

Andrea WILMS GSI, Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany

Andrea WILMS GSI, Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany GSI, Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany E-mail: A.Wilms@gsi.de During the last years the experimental demands on photodetectors used in several HEP experiments have increased

More information

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector) Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector) Valeri Saveliev University of Obninsk, Russia Vienna Conference on Instrumentation Vienna, 20 February

More information

LIFETIME OF THE MUON

LIFETIME OF THE MUON Muon Decay 1 LIFETIME OF THE MUON Introduction Muons are unstable particles; otherwise, they are rather like electrons but with much higher masses, approximately 105 MeV. Radioactive nuclear decays do

More information

80 Physics Essentials Workbook Stage 2 Physics

80 Physics Essentials Workbook Stage 2 Physics 80 Physics Essentials Workbook Stage 2 Physics the thickness of the tissue: Obviously, the thicker the tissue through which the X-rays have to pass the more they will be absorbed from the beam passing

More information

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

PMT tests at UMD. Vlasios Vasileiou Version st May 2006 PMT tests at UMD Vlasios Vasileiou Version 1.0 1st May 2006 Abstract This memo describes the tests performed on three Milagro PMTs in UMD. Initially, pulse-height distributions of the PMT signals were

More information

CMS Conference Report

CMS Conference Report Available on CMS information server CMS CR 2004/067 CMS Conference Report 20 Sptember 2004 The CMS electromagnetic calorimeter M. Paganoni University of Milano Bicocca and INFN, Milan, Italy Abstract The

More information

Chapter 3 OPTICAL SOURCES AND DETECTORS

Chapter 3 OPTICAL SOURCES AND DETECTORS Chapter 3 OPTICAL SOURCES AND DETECTORS 3. Optical sources and Detectors 3.1 Introduction: The success of light wave communications and optical fiber sensors is due to the result of two technological breakthroughs.

More information

Silicon Photo Multiplier SiPM. Lecture 13

Silicon Photo Multiplier SiPM. Lecture 13 Silicon Photo Multiplier SiPM Lecture 13 Photo detectors Purpose: The PMTs that are usually employed for the light detection of scintillators are large, consume high power and are sensitive to the magnetic

More information

Optical behavior. Reading assignment. Topic 10

Optical behavior. Reading assignment. Topic 10 Reading assignment Optical behavior Topic 10 Askeland and Phule, The Science and Engineering of Materials, 4 th Ed.,Ch. 0. Shackelford, Materials Science for Engineers, 6 th Ed., Ch. 16. Chung, Composite

More information

Detectors for Sensitive Detection: HyD

Detectors for Sensitive Detection: HyD Detectors for Sensitive Detection: HyD R. T. Borlinghaus*, H. Birk and F. Schreiber Leica Microsystems, Am Friedensplatz 3, 68165 Mannheim, Germany This article discusses detectors (more precisely: sensors),

More information