1 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 44, no. 5, september Elevation Performance of 1.25D and 1.5D Transducer Arrays Douglas G. Wildes, Member, IEEE, Richard Y. Chiao, Member, IEEE, Chris M. W. Daft, Member, IEEE, K. W. Rigby, Member, IEEE, L. Scott Smith, Member, IEEE, and Kai E. Thomenius, Member, IEEE Abstract Present 1D phased array probes have outstanding lateral and axial resolution, but their elevation performance is determined by a fixed aperture focused at a fixed range. Multi-row array transducers can provide significantly improved elevation performance in return for modest increases in probe and system complexity. Timedomain simulations of elevation beam profiles are used to compare several types of multi-row probes. The elevation aperture of a 1.25D probe increases with range, but the elevation focusing of that aperture is static and determined principally by a mechanical lens with a fixed focus (or foci). 1.25D probes can provide substantially better near- and far-field slice thickness performance than 1D probes and require no additional system beamformer channels. 1.5D probes use additional beamformer channels to provide dynamic focusing and apodization in elevation. 1.5D probes can provide detail resolution comparable to, and contrast resolution substantially better than, 1.25D probes, particularly in the mid- and far-field. Further increases in system channel count allow the use of 1.75D and 2D arrays for adaptive acoustics and twodimensional beam steering. Significant improvements in clinical image quality can be expected as multi-row probes become increasingly available in the marketplace. I. Introduction The development of instruments for medical ultrasound has generated a steady improvement in axial and lateral resolution over the last 30 years. During this period transducers have developed from relatively low frequency, manually operated, single-element transducers to electronically steered linear arrays with more than 200 elements. Typical operating frequencies for general abdominal imaging applications have increased from 2.5 MHz or lower to 3.5 MHz or higher. This change has been achieved by the use of more sensitive pre-amplifiers, improvements in transducer technology, and better matching between the transducer elements and the transmit-receive electronics. The common goal of all these changes has been the improvement in lateral and, to a lesser degree, axial resolution. It is, however, becoming increasingly difficult to improve upon these two parameters because the easily achievable modifications have already been implemented. One aspect of system performance that has received relatively little attention in recent years is that of beamwidth in the plane perpendicular to the imaging plane, often referred to as the elevation beamwidth or slice thickness. Manuscript received July 1, 1996; accepted March 10, The authors are with GE Corporate Research and Development, Schenectady, NY ( wildes@crd.ge.com). Considerable attention was given to this issue in the late 1970 s and early 1980 s [1] [5]. There are two main reasons slice thickness has received less attention than either lateral or axial resolution. First, changes in elevation beamwidth do not affect the display of a B-scan image as dramatically as do changes in lateral and axial resolution, because the improved direction is perpendicular to the plane of the display. Second, building transducer arrays with the required elevational properties has been difficult. The already small transducer elements must be further subdivided and independently controlled. Only with the recent development of more sophisticated electronics has the construction and control of the needed transducer arrays been successfully addressed. Moreover, due to reasons involving ease of fabrication, most of today s test phantoms involve cylindrical targets (e.g., wires or cylinders with varying diameters and backscatter strengths). These phantoms are especially insensitive to changes in elevational beamwidth which offer mainly improvements in contrast resolution and in the detectability of very small lesions. To control the slice thickness, most current transducers use a fixed lens or curved transducer elements to create a fixed mechanical focus at a desired range. The f-numbers used with these designs are relatively high (e.g., f/3to f/6 in elevation vs. f/1tof/2 in azimuth). The goal is to have a reasonable depth of focus in the elevation direction. The lack of attention to the elevation performance is slowly beginning to change. Three companies are advertising systems with electronically adjustable elevation focus. Rownd et al. [6] have developed spherical void phantoms with the specific goal of determining the ability of a scanner to detect small diameter, cyst-like targets. Similarly, Vilkomerson et al. [7] have proposed a new resolution metric with a similar goal: how well can an imager detect a small target in a region of uniform backscatter. To address the elevation focusing issue, several different transducer schemes have been proposed [8]. In this paper, these schemes are referred to as 1D, 1.25D, 1.5D, 1.75D, and 2D arrays and are defined as follows: 1D: Elevation aperture is fixed, and focused at a fixed range. 1.25D: Elevation aperture is variable, but focusing remains static. 1.5D: Elevation aperture, shading, and focusing are dynamically variable, but symmetric about the centerline of the array /97$10.00 c 1997 IEEE

2 1028 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 44, no. 5, september D: A 1.5D array without the symmetry constraint. Elements are large (several wavelengths) in elevation, so very little steering is possible. 2D: Elevation geometry and performance are comparable to azimuth, with full electronic apodization, focusing, and steering. This paper illustrates the elevation beamforming capabilities of 1.25D and 1.5D arrays by exploring several of the tradeoffs which are inherent to the design of those arrays. A broadband three-dimensional simulator, described in Section II, is used to compute elevational beam profiles of specific transducer designs. A prototypic 1D linear array is defined in Section III. Section IV describes two alternative 1.25D extensions to the 1D design. Analytic approaches to optimizing the geometry and beamforming of a 1.5D array are explored in Section V; the performance of specific 1.5D designs is discussed in Section VI. Some of the features and issues associated with 1.75D and 2D arrays are reviewed in Section VII. II. Modeling Acoustic Radiators To investigate the properties of multi-row arrays, a computationally efficient three-dimensional simulator is required. Since typical imaging pulses are short, a time domain approach is appropriate. Harris [9], [10] has reviewed the classical methods for computing transient fields from baffled pistons. The method used here constructs the field from a plane radiator by convolution. The pressure p(r,t) can be expressed as the convolution of a spatial impulse response h(r,t) and the time derivative of the transducer response Ė(t): p(r,t) Ė(t) h(r,t). (1) Piwakowski and Delannoy [11] give a method for efficiently computing h(r,t): h(r,t)= 1 v(x,y )α(θ)δ[t R/V s d(x,y )] ds. 4π S R (2) Here, h(t) is in units of velocity potential divided by time [12]. The region of integration S is the surface of the transducer. v(x, y) is the normal component of the velocity of the surface of the transducer, d(x, y) is the beamforming time delay at a given point, θ is the angle between the normal to ds and the field point r, α(θ) is an inclination factor determined by the boundary condition, V s is the speed of sound in tissue, and R is the distance from ds to the field point r. In [11], a discrete representation of h(r,t) is obtained which has a simple physical interpretation. Imagine the surface of the transducer divided into small areas S j. Each area emits a spherical, impulsive wave with propagation time t j = R j + d j (3) to the field point. (R j and d j are discretized versions of the variables R and d(x, y) above.) The amplitude of the impulse received at the field point is proportional to the velocity of the elemental area v j and to 1/R j. Piwakowski and Delannoy [11] show that, if the number of elemental areas is large enough, a band-limited approximation to the acoustic field can be obtained by summing the effect of each area in the radiator. In a numerical simulation, a vector represents the impulse response at the field point as a function of time. The time t j is calculated for each elemental area on the transducer and specifies the element in the vector to which S j contributes. That element of the vector is incremented by v j α/r j. This method of computing the integral has the virtues of speed and intuitive simplicity. The dimensions of the transducer array are specified in v(x, y); this matrix has zero entries for positions on the integration grid outside the transducer. A constant f-number can be maintained by changing v(x, y) as a function of range. The effects of apodizing and shading are modeled with v(x, y). The integration grid is substantially finer than the pitch of the transducer elements, which allows the angular response of each element to be included. The inclination factor, a consequence of operating the highimpedance transducer into a comparatively low-impedance material (tissue), is modeled by α(θ) in (2). Steering and focusing information is encoded in the delay array d(x, y). In the one-dimensional case, a physical lens in the elevation (y) direction is modeled by a fixed focus delay t(y) = F y V s [ 1+ y2 F 2 y ] 1. (4) This equation ignores refraction and the 1/ cos θ dependence of the path length through the lens on the angle from each transducer source point to the field point. A comparison of (4) to a near-exact calculation of the lens effect shows, for the 1D probe in Fig. 1, that the time-delay error is less than the time quantization of our simulation for field points on the beam axis or in the mid and far field of the probe. Even in the near field, the error remains less than λ/10 for field points within the main lobe of the beam. In a 1.5D, 1.75D, or 2D array, the elevation focal point F y can be varied dynamically. The beam can also be steered in the y direction if there are enough elements (1.75D, 2D). In azimuth, the beam steering and focusing are done with the standard parabolic approximation [13]: t(x) = 1 ( ) x sin θ + x2 cos 2 θ, (5) V s 2F x where F x is the focal length. The effects of tap lengths in delay lines can be studied by quantizing d(x, y). Once the impulse response is calculated, the convolution in (1) is performed with FFTs. The result is a vector of pressure versus time for each field point. The maximum absolute value at each field point is used in the beam plots.

3 wildes et al.: 1.25d and 1.5d transducer arrays 1029 Fig. 1. Elevation performance of a 5 MHz, 1D linear array. The elevation aperture is 10 mm and the lens is focused at 50 mm ( ). (a) Elevation cross-section of probe. (b) Contour plot of elevation cross-section of beam, normalized to 0 db at each range. (c) Elevation beam profiles in near field (dashed line), at lens focus (solid line), and in far field (dotted line). Vertical lines on (b) show ranges of beam profiles in (c); horizontal lines on (c) show contours plotted in (b). For the simulations presented in this paper, the transducer array was sampled on a rectangular grid with pitch λ/4, with a minimum of seven grid lines per transducer element in both elevation and azimuth. The impulse response at each field point was calculated with 5 nsec resolution. For the contour and beam profile plots, the acoustic field was sampled every 0.5 mm in elevation and every 2 mm in range. A typical simulation (Fig. 1) involved the calculation of time delays and amplitudes from about 10 5 points on the transducer to each of about 2500 field points and a 16K 16K point convolution at each field point. In optimized C code on a Sun SPARC 20 workstation, this computation requires about 20 minutes. To validate the simulation software, beam profiles of a 3.75 MHz 1.5D sector probe were measured [14]. Fig. 2 shows simulated versus measured elevation beam profiles at the lens focus (80 mm) and in the far field (140 mm). Since the simulations are one-way, one-way (receive only) measurements were made, using a small isotropic source (Specialty Engineering Associates, Milpitas, CA 95035) at the appropriate depth in the water tank. The level of agreement is sufficient to give good confidence in the operation of the simulation software. The structure of the sidelobes is largely due to the complex waveform from the isotropic source. Differences between the simulated and measured beam profiles may be due to an inexact match between the waveform used for the simulation and that achieved during the measurement or to differences between Fig. 2. Simulated (solid line) and measured (dashed line) beam profiles for a 3.75 MHz, 1.5D sector probe. The elevation aperture is 20 mm, divided into 5 rows, with a lens focused at 80 mm. Beam profiles shown are (a) at the lens focus and (b) in the far field. the time-delay beamformer of the simulator and the baseband beamformer of the measured imaging system. Other effects, such as refraction in the lens and quantization in the beamformers, are expected to be much smaller in magnitude. III. 1D Array As a reference case for this paper s exploration of multirow transducers, consider the prototypic 5 MHz 1D linear array transducer sketched in Fig. 1(a). In elevation, this probe has a 10 mm aperture and a 50 mm lens focus. In azimuth, the array has 128 elements at a pitch of 0.3 mm ( λ). A Gaussian impulse response with 70% bandwidth is assumed for ease of simulation. A contour plot of the elevation beam profile of this array is shown in Fig. 1(b). This is a one-way (receive only) simulation of a beam directed perpendicular to the face of the transducer. The azimuthal aperture opens at f/2 and is dynamically focused at each range. The plot shows a slice through the center of the beam, perpendicular to the usual imaging plane. At each range, the maximum pressure in the beam profile is set to 0 db, so the variation of sensitivity with range is normalized out. The contour plot therefore emphasizes the variation of the elevation beam width over the imaging range of the probe. Fig. 1(c) shows elevation beam profiles at three ranges marked by the vertical lines in Fig. 1(b). The horizontal lines in Fig. 1(c) show the positions of the contour lines of Fig. 1(b). The 6 db contour shows the main lobe width or detail resolution of a probe. The 20 db contour is an

4 1030 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 44, no. 5, september 1997 Fig. 3. A 1.25D array with a single-focus lens. The elevation aperture is 10 mm, divided into three rows, with a lens focused at 65 mm ( ). (a) Elevation cross-section of probe, showing electrical connections to rows. (b) Contour plot of elevation cross-section of beam, normalized to 0 db at each range. (c) Elevation beam profiles in near field, at lens focus, and in far field. Vertical lines on (b) show ranges of beam profiles in (c); horizontal lines on (c) show contours plotted in (b). indicator of the width of the sidelobes and, therefore, of the contrast resolution of the probe. The elevation performance of this simulated probe is typical of most commercial 1D array transducers. The focal length of the lens is chosen to give maximum contrast resolution near the imaging range of greatest importance for the intended application for the probe. The elevation aperture is a tradeoff between contrast resolution and sensitivity near the lens focus (improved by a larger aperture) and depth of field or contrast away from the focus (improved by a smaller aperture). An aperture between f/3 and f/6 is usually chosen. Such an aperture gives good slice thickness and contrast resolution near the lens focus, but rather poor performance in the near and far field. IV. 1.25D Arrays One approach to improving the near- and far-field elevation performance of a transducer is illustrated by the 1.25D array sketched in Fig. 3(a). The azimuthal properties of this array (and all subsequent 1.25D and 1.5D arrays) are identical to those of the 1D array described in Section III. The elevation of the transducer has been divided into three rows. The outer rows are electrically connected in parallel, and the signal leads from the elements in the combined outer rows are connected to the signal leads from the center row by an array of electronic switches (multiplexor). In practice, the outer rows are connected together within the probe head, whereas the multiplexor may be located within the probe head, at the console end of the probe cable, or within the system console itself. For the design simulated here, the combined area of the outer rows is equal to the area of the center row, so that their electrical impedances and acoustic sensitivities are equal. Because changing the state of the mux switches generates noise, use of this probe typically requires two transmit-receive cycles per beam. With the mux switch open, the transmit delays are set to provide azimuthal focusing in the near field, and the near portion of the beam data is acquired. The mux switches are then closed, the transmit delays reconfigured, and the far field data is acquired. Data from the two zones are blended together in the imaging system, with care being taken to compensate for the change in sensitivity at the transition. The near-field performance of this array is principally determined by the width of the center row. The focal length of the lens is in the far field for the center row (d 2 /4λ 21 mm for this array), so the lens has only a weak effect on the first zone. The far-field performance, however, is strongly affected by both the lens focus and the total elevation aperture. If the aperture is held constant, but the lens focal length is increased relative to that of the 1D transducer, the f-number and depth of field are increased and the far field of the 1.25D array is significantly improved, with a minimal effect on the near field. The contour plot in Fig. 3(b) and beam profiles in Fig. 3(c) show the performance with a 65 mm lens focus, 30% greater than the focal length of the 1D array in Fig. 1. To further improve the elevation performance of the prototype transducer, while remaining within the constraints of 1.25D imaging (no dynamic focusing in elevation), consider the design in Fig. 4. This is a five-row array with a 12 mm elevation aperture and a multi-focus lens. As more rows are added to the array, the per-row width can be reduced to improve the near-field performance and the total elevation and lens focus may be increased to improve the far field. The multifocus lens on this array, shown in Fig. 4(a), provides a delay function that is continuous across the elevation aperture but has a different curvature (focal length) for each row. Discontinuous delay functions are also possible, either by introducing discontinuities in the lens (which may cause diffraction artifacts) or by inserting static delay elements in the signal path between each row of elements and the mux [15], [16]. The advantage of a multifocus lens is that it substantially increases the depth of field, providing uniform resolution ( 6 db contour) and contrast ( 20 db contour) over essentially the entire imaging range of the probe. The disadvantage is that the sidelobes do not fall off quite as fast as those of a single-focus lens near its focal point. Compare the Z = 65 mm beam profile in Fig. 4(c) to that in Fig. 3(c). Elevation contours for the example 1D and 1.25D designs are compared in Fig. 5(a). The 1.25D designs provide near-field and far-field performance (slice thickness contrast resolution) which is substantially better than con-

5 wildes et al.: 1.25d and 1.5d transducer arrays 1031 ventional 1D probes, and use no additional system beamformer channels. Although the system impact is minimal, the improved imaging performance comes at the cost of a significant increase in the complexity of the transducer pallet, cable assembly, and multiplexor. Fig. 5 shows that the increased elevation aperture and lens focal distance can contribute several db to the probe s acoustic sensitivity in the far field; however, these gains may be offset by increased losses in the multiplexor and cable assembly. V. Optimal 1.5D Elevation Geometry 1.5D arrays, which add dynamic elevation focusing to the features of 1.25D probes, offer the next level of improved elevation performance. To gain an appreciation for the number of parameters which must be specified in the design of a 1.5D probe, consider in more detail the elevation focusing described by (4): the time-delay error t at an elevation position y on a transducer for signals arriving from an on-axis field point at range R is: Fig. 4. A 1.25D array with a multi-focus lens. The elevation aperture is 12 mm, divided into five rows, with a lens focused ( ) at 40 mm (center row), 70 mm (inner rows), and 100 mm (outer rows). (a) Elevation cross-section of probe. The lens profile is exaggerated. (b) Contour plot of beam, normalized to 0 db at each range. The solid contours reflect use of the optimum aperture at each range. (c) Elevation beam profiles in near field, mid field, and far field. V s t(y, R) = ( R2 + y 2 R) ( [( R 2 + y 2eff R ) F 2 ) lens + y2 F lens ( Flens 2 + y2 eff F lens (6) )] where V s is the speed of sound, the first term is the acoustic path length for an unfocused transducer, the second term is the elevation focusing provided by a fixed lens with focal distance F lens (4), and the third term is dynamic elevation focusing by an electronic beamformer which treats the element as a point at elevation y eff. For a 1.25D probe, with no dynamic focusing in elevation, y eff 0andthe third term drops out. For simplicity, the constant terms are arranged to give zero delay error at y eff and F lens. Only the elevation axis is considered, so that the model is one-dimensional. Expanding the square roots and keeping only the leading terms produces a simple parabolic model for all of the propagation and beamforming delays. With this approximation, the time-delay error becomes ( 2V s t(y, R) = y2 R y2 1 yeff 2 F lens = ( y 2 y 2 eff ) ( 1 R 1 F lens R 1 ) (7) F lens ). (8) Fig. 5. Comparison of 1D and 1.25D array performance: The dotted lines are the 1D probe of Fig. 1, the dashed lines are the 3-row, single-focus 1.25D probe of Fig. 3, and the solid lines are the 5-row, multi-focus 1.25D probe of Fig. 4. All three probes are identical in azimuth: 128 elements, pitch 0.3 mm ( λ at 5 MHz), dynamically focused, and dynamically apodized to maintain f/2. (a) Contour plot of beams, normalized to 0 db at each range. (b) Sensitivity along the beam axis. As a simple first case, consider a 1.5D probe with five rows and a single-focus lens. The array is symmetric about y = 0, with the outer limits of the rows at ±y 1, ±y 2,and ±y 3 (Fig. 6). The center row extends across y =0and the outer rows are electrically connected in pairs across y = 0, so that the elevation beamforming is also symmetric [Fig. 7(a)]. The effective y positions of the paired rows for beamforming are y1 eff, y2 eff,andy3 eff.

6 1032 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 44, no. 5, september 1997 Fig. 7. Comparison of 1.5D arrays with equal-area rows (dashed line), Fresnel row pitch (dotted line), and Minimum Integrated Absolute time-delay Error row pitch (MIAE, solid line). Each probe has a 12 mm elevation aperture divided into five rows and a lens focused at 65 mm ( ). (a) Elevation cross-section of probe (equal area), showing electrical connections to rows. (b) Contour plot of beams, normalized to 0 db at each range. (c) Elevation beam profiles in the far field. Fig. 6. Focus error (in wavelengths) across the elevation aperture at representative ranges for different 1.5D and 1.25D elevation geometries. (a) 1.5D Fresnel array with row widths and y eff (for electronic focusing) determined by (12) and (13). The lens focus is at 65 mm; focus errors are plotted at 40 mm (solid lines) and 120 mm (dashed lines). The maximum absolute time-delay error is range-dependent and occurs at the array center and the row boundaries. As the focal distance varies, the focus error curve is scaled, but its shape does not change. (b) 1.5D probe with Minimum Integrated Absolute time-delay Error (MIAE). Row widths and y eff are determined by (17) and (18). The lens focus is at 65 mm; focus errors are plotted at 40 mm (solid lines) and 120 mm (dashed lines). (c) 1.25D probe with equal-area rows and a multifocus lens (Fig. 4). The focus error is plotted at the turn-on range for the inner rows (30 mm), at the turn-on of the outer rows (60 mm), and in the far field. The shape of the focus error curve varies with range. A criterion for minimizing the time-delay errors can be used to determine the relative row widths and the effective y positions for beamforming. The total elevation aperture must be established independently (otherwise the minimum error solution is an array of zero width). Along with the probe and beamforming geometry, the elevation apodization must also be specified. In practice, with the exception of the very near field, best 1.5D performance is obtained with all rows active at all ranges. Dynamic shading in elevation plays a critical role in determining the beam profile, but it is not included in the present timedelay error analysis. As a result, the following solutions are most relevant near and beyond the lens focus, where the aperture is wide open and the shading is relatively flat. One approach to optimizing the array is to minimize the maximum absolute time-delay error across the aperture. This leads to a solution with equal absolute error at the inner and outer edge of each row: t(y =0,R) = t(y 1,R) =...= t(y N,R) With a single-focus lens, the dependence of (8) on R and F lens factors out and (9) reduces to: 0 (y1 eff ) 2 = y 1 2 (y1 eff ) 2 = y 1 2 (y2 eff ) 2 = y 2 2 (y2 eff ) 2 (10) = y 2 2 (y3 eff ) 2 = y 3 2 (y3 eff ) 2, which may be quickly solved: (9) (y eff i ) 2 =(1/2)(y 2 i 1 + y 2 i ) y 2 i y 2 i 1 = constant (11) with y 0 0. This is a version of the classic Fresnel lens [13]. Numerically, for a five-row array, (y 1,y 2 ) (0.577, 0.817)y 3 (12) (y1 eff,y2 eff,y3 eff ) (0.408, 0.707, 0.913)y 3. (13)

7 wildes et al.: 1.25d and 1.5d transducer arrays 1033 A plot of the time-delay error across the elevation aperture for a probe of this design is shown in Fig. 6(a). Note that y eff of the center row is nonzero. This can be made zero, by adding a constant time-delay error across the array, which is, of course, irrelevant. An alternate approach to optimizing the design of a 1.5D array is to minimize some average of the time-delay error over the entire aperture, rather than just the worstcase error at a few points. Consider, for instance, the absolute value of the time-delay error integrated across the array: I(y 1,y 2,y eff 1,y2 eff,y3 eff )= y1 y2 0 t 1 dy + y 1 t 2 dy + y3 y 2 t 3 dy, (14) where t i (y, yi eff ) is the time-delay error across the i th row, and the factor of two due to symmetry has been omitted. The integrated error I is minimized by imposing which leads to I/ y i =0, i =1, 2 I/ yi eff =0, i =1, 2, 3, (15) yi eff =(1/2)(y i 1 + y i ) y 2 /y 1 = 7 1 y 3 /y 1 = , (16) with y 0 0. Numerically, (y 1,y 2 ) (0.458, 0.754)y 3 (17) (y1 eff,y2 eff,y3 eff ) (0.229, 0.606, 0.877)y 3. (18) The time-delay error across the elevation for this design is shown in Fig. 6(b). Relative to the Fresnel design in Fig. 6(a), the focus error in the center of the array is substantially reduced and the error on the outer rows is only modestly increased. Minimizing the integrated squared error leads to a slightly different choice of row widths and effective positions, but the resulting beamprofiles are similar. As a second test case for the analytic optimization of a multi-row probe design, consider a 1.25D probe with a multifocus lens. Dynamic focusing and shading in elevation are not available, and the elevation performance of the probe is determined by the row widths, turn-on ranges, and lens foci. A range-independent optimization of (8) in the far field no longer makes sense; a global optimization which balances the performance of the one-row, three-row, and five-row apertures is needed. The authors have tried several different analytic optimization strategies with little success. Minimizing the integral of the absolute value of the time-delay error is analytically intractable. Minimizing the worst-case absolute time-delay error at the turn-on range for each row and at some arbitrary point in the far field is feasible, but leads to designs with only mediocre elevation performance. Neither approach provides enough constraints to determine all the free parameters in the design. In the end, equal-area rows were selected for uniformity of element impedance and the lens foci and turn-on ranges were determined by trial and error. The resulting transducer design was described in Section IV; its elevation performance is shown in Fig. 4, and the time-delay error across its aperture is shown in Fig. 6(c). VI. 1.5D Arrays In order to support dynamic elevation focusing, 1.5D arrays require many more beamforming channels and connections than 1.25D arrays. Elevational beam control for 1.25D arrays is accomplished only with a lens and multiplexor. All elements within each elevational column of a 1.25D array are connected to the same beamforming channel and share the same electronic time delay and shading. In contrast, 1.5D arrays use dynamic focusing and shading to control the elevational beam. With elevational symmetry (no steering), this requires an independent beamforming channel for each pair of elevational elements, as illustrated in Fig. 7(a). The design of the row widths and lens should optimize the round-trip beam generated with dynamic focusing and shading over all ranges of interest. In azimuth, an element is well approximated by a point source at the center of the element for purposes of computing the beamforming delay; however, the proper choice of beamforming delay for a wide elevational element is less clear, since there is a range of distances between that element and any single point in space. The distinction between a simple and compound lens is less important for 1.5D than 1.25D. In a 1.25D array the lens is the only focusing mechanism and having a compound lens is crucial for maintaining good detail and contrast resolution over an extended range. In a 1.5D array the electronic focusing and apodization are sufficiently effective that a compound lens provides little advantage over a simple lens. The lens focus should be near the center of the range of interest. For the prototypic 5 MHz probe with a range of interest from 5 to 120 mm, a lens focus of 65 mm is effective. Three different strategies for selecting the row widths of a 1.5D probe are compared in Fig. 7. The design with equal-area rows (dashed line) provides uniform element impedance and sensitivity. The Fresnel design (12) (dotted line) minimizes the maximum delay error across the aperture. The Minimum Integrated Absolute time-delay Error (MIAE) design (17) (solid line) is the result of the optimization strategy described in Section V. In the far field, as shown by the beam profiles in Fig. 7(c), the MIAE optimization strategy pays off. The MIAE probe has low, relatively uniform sidelobes, avoiding both the 18 db shoulder of the Fresnel beam profile and the 27 db grating lobe of the equal area probe. In the near field, the elevation performance is determined by

8 1034 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 44, no. 5, september 1997 Fig. 8. Comparison of 1.5D arrays with three (dotted line), five (dashed line), and seven (solid line) rows. Each probe has a 12 mm elevation aperture divided into rows of equal area and a lens focused at 65 mm ( ). (a) Contour plot of beams, normalized to 0 db at each range. (b) Elevation beam profiles in near field. (c) Elevation beam profiles in far field. Fig. 9. Comparison of 1D, 1.25D, and 1.5D array performance: The dotted lines are the 1D probe of Fig. 1, the dashed lines are the five-row, multifocus 1.25D probe of Fig. 4, and the solid lines are the five-row, equal-pitch 1.5D probe of Figs. 7 and 8. (a) Contour plot of beams, normalized to 0 db at each range. (b) Elevation beam profiles near the lens foci. (c) Elevation beam profiles in the far field. the width of the center row and the equal area design will have an advantage. The contour plot of Fig. 7(b) compares the three design strategies over the entire imaging range of the probe. The near field performance of the equal area design clearly outweighs the relatively subtle advantages ofthemiaedesigninthefarfield. Fig. 8 shows the effect of changing the number of rows while holding the total aperture constant. Because the total apertures are the same, all three designs have comparable detail resolution ( 6 db contours), except in the very near field, where the elevation performance is determined by the size of the center row. The principal effect of the number of rows and the row widths is on the contrast resolution, as indicated by the 20 db contours and by the sidelobe levels in the beam profiles. The seven-row array has sidelobes 7 to 12 db lower than the three-row probe, and twice the depth of field. The five-row probe is only marginally better than the three-row in the near field, but approaches the performance of the seven-row in the far field. Elevation contours and beam profiles of representative 1D, 1.25D, and 1.5D arrays are compared in Fig. 9. The 1.25D and 1.5D probes provide similar, relatively uniform detail resolution ( 6 db contours) over the entire imaging range. The 1.5D probe offers substantially superior contrast resolution ( 20 db contours and sidelobes in beam profiles). The simulations above assume 128 channels for every row of the array. In practice, the allocation of channels to rows is an important design choice given the limited number of beamformer channels available. To preserve azimuthal performance, it is important that the active azimuthal aperture and element pitch of a 1.5D probe be comparable to those of the competitive 1D probes. Use of the full aperture of a three- or five-row 1.5D probe could therefore require two or three times the number of beamformer channels as are used by a comparable 1D probe. Fortunately, the situation is not quite this bad. An elliptical active aperture reduces the number of channels used by the outer rows and produces a beam profile which is superior to the beam profile of a rectangular aperture [14]. In addition, synthetic aperture techniques and multiple transmit-receive cycles may be used to obtain 256- or 512-channel performance from a 128-channel imager. Fully optimizing the performance of a 1.5D probe involves delicate tradeoffs between the effective channel count, the number of transmit focal zones along each beam, and the frame rate of the resulting image. The optimum transducer design may be one which supports several different modes of operation, for B-mode versus color-flow imaging and for low-tissue-motion radiology studies versus more rapid-movement vascular, obstetrical, and cardiac imaging. VII. 1.75D and 2D Arrays For completeness, some of the performance features and problems expected from 1.75D and 2D probes are outlined here. As mentioned in the introduction, release from the elevation symmetry constraint is the major feature which

9 wildes et al.: 1.25d and 1.5d transducer arrays 1035 separates 1.75D and 2D arrays from 1D, 1.25D, and 1.5D arrays. With independent control of the beamforming time delays for all elements in the aperture, 2D beam steering and other types of dynamic beam shaping become possible. With 1.75D transducers, where the element dimensions and row pitch in elevation are large compared to an acoustic wavelength, elevation beam steering is constrained by the small acceptance angle of the elements and by grating lobes close to the main beam. When the beam is directed straight ahead, the grating lobes of a dense, equal-pitch array coincide with nulls of the single-element diffraction pattern and have little power. As the beam is steered in elevation, the main beam loses power as it moves away from the peak of the element directivity function, while a grating lobe gains power as it moves toward the peak. Elevation steering of 1.75D arrays is, therefore, limited to angles within a few degrees of a plane normal to the face of the array. While not sufficient for full 3D imaging, this limited steering capability may be very useful for vector flow applications and for small deflections of the imaging plane to measure the 3D extent of small cysts, vessels, and other structures in the body. In addition, providing an independent beamforming channel for each transducer element allows one to compensate for inhomogeneous propagation velocities in the body (or nonuniformities in the imaging system or transducer). Called phase aberration correction or adaptive acoustics, such imaging approaches offer the promise of substantial improvement in image quality and are an active research area [17] [20]. As the number of elevation rows in the transducer increases and the size of the elements decreases, the importance of a fixed physical lens decreases. When the elements are large in elevation, the time delay variation across a single element is still so large that a lens is required. As the element size decreases, the lens can be abandoned in favor of fully electronic beamforming. Only when the array pitch in both elevational and azimuthal directions becomes comparable to a half wavelength (i.e., true 2D arrays) are the benefits of full 3D beamforming realized [21]. With this small element size, beamsteering at substantial angles in elevation (>20 degrees) is now possible. Moreover, oblique imaging planes unconstrained by the axes of the probe can be selected under fast electronic control rather than by comparatively slow manual repositioning of the probe. Again, there are two realms of interest, dense and sparse, based on element coverage of the aperture. In a fully dense array with the order of 100 elements in both azimuth and elevation [2], the total number of elements ( 10,000) is significantly larger than anything currently in use. Sparse arrays, however, have been used by several groups [22] [24] to study various aspects of electronically controlled 3D ultrasound imaging. Although the spacing between individual elements is on average larger than about a half wavelength, there are enough instances within the array where the sampling is at high spatial frequencies to suppress sidelobes to a respectable level. Specialized signal processing algorithms designed explicitly for such sparse array structures provide satisfactory beamprofiles over a wide range of azimuthal and elevational angles [25] [27]. Both 1.75D and 2D arrays present substantial challenges to the system designer. As the array elements become smaller, the fabrication difficulties associated with making electrical connections to the individual elements increase rapidly. The increasing number of cables required to connect the transducer elements to the rest of the system causes problems of size, weight, and cable management. The impedance mismatch between the element and the cable rapidly worsens as the element size decreases [23]. Moreover, the effective signal-to-noise ratio drops precipitously. Both of these effects can be reduced by integrating some beamformer electronics with the transducer; however, this kind of integration is likely to be most effective when used with nontraditional beamformer architectures. The large number of elements leads to other difficulties. As the number of elements in the array increases, either the number of independent electronic channels in the beamformer must also increase or some multiplexing scheme must be used to select subsets of elements for connection to a smaller number of electronic beamforming channels. These two choices lead to a large increase in system cost or a significant reduction in image acquisition frame rate, respectively. Since neither of these options is attractive, there is considerable opportunity for creative engineering, either as an optimized tradeoff among the various constraints or as a paradigm shift to an entirely new approach circumventing the current difficulties. VIII. Conclusions Elevation beam profiles of 1D and multi-row transducer arrays were calculated using a three-dimensional timedomain simulator. Present 1D phased array probes have outstanding lateral and axial resolution, but their elevation performance is determined by a fixed aperture focused at a fixed range. Several types of multi-row array transducers, which provide significantly improved elevation performance in return for modest increases in probe and system complexity, were reviewed. The elevation aperture of a 1.25D probe increases with range, but the elevation focusing of that aperture is static and determined principally by a mechanical lens with a fixed focus (or foci). 1.25D probes can provide substantially better near- and far-field slice thickness performance than 1D probes, and require no additional system beamformer channels. 1.5D probes use additional beamformer channels (at least twice as many) to provide dynamic focusing and apodization in elevation. 1.5D probes can provide detail resolution comparable to, and contrast resolution substantially better than, 1.25D probes, particularly in the midand far-field. Further increases in system channel count will allow the use of 1.75D and 2D arrays for adaptive acoustics and two-

10 1036 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 44, no. 5, september 1997 dimensional beam steering. Several academic groups and many medical ultrasound companies are actively developing the probe and system technology necessary for multirow transducer arrays. New breakthroughs in image quality can be expected as the results of their efforts become available in the marketplace. Acknowledgments The authors would like to thank their colleagues at GE CRD and GE Medical Systems, including Motoyoshi Ando, Walt Berninger, Ajay Bhave, Ed Bielawa, Elizabeth Burke, Carl Chalek, Stanley Chim, John David, Ray De- LaRosa, Tom Deitrich, Len Douglas, Evan Downey, Lonnie Edelheit, Lisa Fancovic, Mike Fazzone, Gregg Frey, Takeuki Goto, Anne Hall, Dave Hanchar, Mike Harsh, Bill Hatfield, Bill Hennessy, Omar Ishrak, Amanda Jeffries, Brady Jones, Jack Keres, John Kese, Bill Kornrumpf, Kris LaConte, Aminah Lawery, Don Lester, Bill Leue, Bob Lewandowski, Greg Lillegard, Ric Lisowski, Xuan-Ming Lu, Brian McEathron, Dan Miller, Steve Miller, Larry Mo, Atsushi Morimoto, Ed Nonnweiler, Sharbel Noujaim, Mitsuhiro Nozaki, Tim Nustad, Lloyd Ober, Satchi Panda, Kathy Panton, Brenda Peck, Pat Piacente, Joe Piel, Pat Potrykus, Sussan Pourjavid, Ted Rhyne, Bill Rohling, Tom Sabourin, Kazuo Sakamoto, Jack Schneider, Ray Schnoor, Patti Schubert, Said Seyed-Boloforosh, Toru Shimazaki, Jack Sleeter, Jon Snyder, Liliana Sprinceanu, Rob Steins, Jeff Strother, Kota Taguchi, Nim Tea, Tom Thomas, Venkat Venkataramani, Jim Voigt, Kirby Vosburgh, Hsifu Wang, Mike Washburn, and Renee Whitney. Their collaboration in and support of this work is deeply appreciated. References [1] J. F. Gelly and C. Maerfeld, Properties for a 2D multiplexed array for acoustic imaging, Proc. IEEE Ultrason. Symp., 1981, pp [2] T. Kojima, Matrix array transducer and flexible matrix arry (sic) transducer, Proc. IEEE Ultrason. Symp., 1986, pp [3] M. G. Maginness, J. D. Plummer, W. L. Beaver, and J. D. Meindl, State-of-the-art in two-dimensional transducer array technology, Med. Phys., vol. 3, pp , [4] M. Pappalardo, Hybrid linear and matrix acoustic arrays, Ultrasonics, vol. 19, pp , [5] J. D. Plummer, R. G. Swartz, M. G. Maginness, J. R. Beaudouin, and J. D. Meindl, Two-dimensional transmit/receive ceramic piezoelectric arrays: Construction and performance, IEEE Trans. Sonics Ultrason., vol. 25, pp , [6] J. J. Rownd, E. L. Madsen, J. A. Zagzebski, and G. R. Fink, Automated system for rapid ultrasound performance and QA testing in terms of detectability of low contrast focal lesions, Ultrason. Imaging, vol. 17, p. 60, [7] D. Vilkomerson, J. Greenleaf, and V. Dutt, Towards a resolution metric for medical ultrasonic imaging, Proc. IEEE Ultrason. Symp., 1995, pp [8] P. Tournois, S. Calisti, Y. Doisy, J. M. Bureau, and F. Bernard, A channels 1.5D curved linear array for medical imaging, Proc. IEEE Ultrason. Symp., 1995, pp [9] G. R. Harris, Review of transient field theory for a baffled planar piston, J. Acoust. Soc. Amer., vol. 70, no. 1, pp , [10], Transient field of a baffled planar piston having an arbitrary vibration amplitude distribution, J. Acoust. Soc. Amer., vol. 70, no. 1, pp , [11] B. Piwakowski and B. Delannoy, Method for computing spatial pulse response: Time-domain approach, J. Acoust. Soc. Amer., vol. 86, no. 6, pp , [12] H. Lasota, R. Salamon, and B. Delannoy, Acoustic diffraction analysis by the impulse method: A line impulse response approach, J. Acoust. Soc. Amer., vol. 76, pp , [13] G. S. Kino, Acoustic Waves: Devices, Imaging and Analog Signal Processing. Englewood Cliffs, NJ: Prentice-Hall, [14] C. M. W. Daft, D. G. Wildes, L. J. Thomas, L. S. Smith, R. S. Lewandowski, W. M. Leue, K. W. Rigby, C. L. Chalek, and W. T. Hatfield, A 1.5D transducer for medical ultrasound, Proc. IEEE Ultrason. Symp., 1994, pp [15] T. Shimazaki, M. Ando, and H. Tabei, Ultrasound diagnosing device, U. S. Patent , Jan , assigned to Yokogawa Medical Systems, Ltd. [16] D. G. Miller, Ultrasonic transducer system, U. S. Patent , Apr , assigned to Hewlett-Packard Co. [17] S. W. Flax and M. O Donnell, Phase aberration correction in medical ultrasound: Basic principles, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 35, pp , [18] C. Dorme and M. A. Fink, Ultrasonic beam steering through inhomogeneous layers with a time reversal mirror, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 43, pp , [19] G. C. Ng, S. S. Worrell, P. D. Freiburger, and G. E. Trahey, A comparative evaluation of several algorithms for phase aberration correction, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 41, pp , [20] P. C. Li and M. O Donnell, Phase aberration correction on twodimensional conformal arrays, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 42, pp , [21] S. W. Smith, G. E. Trahey, and O. T. von Ramm, Two dimensional arrays for medical ultrasound, Ultrason. Imaging, vol. 14, pp , [22] D. H. Turnbull and F. S. Foster, Two-dimensional transducer arrays for medical ultrasound: Beamforming and imaging, in New Developments in Ultrasonic Transducers and Transducer Systems, F. L. Lizzi, Ed., Proc. SPIE 1733, pp , [23] R. E. Davidsen, J. A. Jensen, and S. W. Smith, Two dimensional random arrays for real time volumetric imaging, Ultrason. Imaging, vol. 16, pp , [24] P. K. Weber, R. M. Schmitt, B. D. Tylkowski, and J. Steck, Optimization of random sparse 2-D transducer arrays for 3-D electronic beam steering and focusing, Proc. IEEE Ultrason. Symp., 1994, pp [25] C. R. Cooly and B. S. Robinson, Synthetic focus imaging using partial datasets, Proc. IEEE Ultrason. Symp., 1994, pp [26] G. R. Lockwood, P. C. Li, M. O Donnell, and F. S. Foster, Optimizing the radiation pattern of sparse periodic linear arrays, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 43, pp. 7 14, [27] G. R. Lockwood and F. S. Foster, Optimizing the radiation pattern of sparse periodic two dimensional arrays, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 43, pp , Douglas G. Wildes (M 85) received the A.B. degree in physics and mathematics from Dartmouth College, Hanover, NH, in 1978, and the M.Sc. and Ph.D. degrees in physics from Cornell University, Ithaca, NY, in 1982 and 1985, respectively. He joined GE Corporate Research and Development in 1985, working initially on the development of a real-time system and signal analysis algorithms for detecting tool failures during the machining of aircraft engine parts. In 1991, he joined the Ultrasound Program, where he has worked on most aspects of phased-array transducer development. For the past several years, he has been project leader for development of multi-row transducers. Dr. Wildes is a member of the American Physical Society and the IEEE.

11 wildes et al.: 1.25d and 1.5d transducer arrays 1037 Richard Y. Chiao (SM 85 M 90) was born in Taipei, Taiwan, in He received the B.S., M.S., and Ph.D. degrees in 1985, 1987, and 1990, respectively, from the Department of Electrical and Computer Engineering at the University of Illinois at Urbana/Champaign. He joined GE Corporate Research and Development in 1990, where he initially worked on ultrasonic imaging for NDE. Since 1995, he has been with the medical ultrasound group at CRD working in the area of beamforming algorithms and architectures. Chris M. W. Daft (M 88) was born in Dundee, Scotland, and received the B.A. and Ph.D. degrees from Oxford University, England, in 1984 and 1987, respectively. From 1987 to 1990 he was with the Bioacoustics Research Laboratory of the Department of Electrical and Computer Engineering at the University of Illinois, as an Assistant Professor. He is currently with GE Corporate Research and Development, Schenectady, NY, in the ultrasound program. While at CRD, he has worked on many aspects of medical ultrasound imaging. Beamforming using VLSI chips has been one focus, as has design of color flow processors. As part of this, he initiated a loosely coupled multi-processor, bit-level simulation of GE s new ultrasound machines. The chips from this work now form the heart of GE s leadership ultrasound system. He has also investigated new types of transducers from a theoretical and experimental viewpoint. Current interests include the optimal detection of ultrasound data, low-cost approaches to beamforming, and transitioning of array design technology to the business. L. Scott Smith (M 90) earned a B.S. from the University of Rochester, Rochester, NY, in 1972, and a Ph.D. in 1976 from the University of Pennsylvania, Philadelphia, PA, both in physics. Since joining GE Corporate Research and Development in 1976, he has worked primarily on medical imaging. He has been cited for his contributions to phased array transducers, digital ultrasound imaging, and high field nuclear magnetic resonance imaging and spectroscopy. Recently he has also worked on transducers for pediatric cardiology. A member of the American Physical Society and the IEEE, Dr. Smith is the author of over 25 papers and 20 patents on medical imaging. Kai E. Thomenius (M 69) earned B.S., M.S. and Ph.D. degrees from Rutgers University, New Brunswick, NJ, in 1968, 1970, and 1978, respectively, all in electrical engineering. After teaching at Rutgers and Stevens Institute of Technology, he has held positions of Project Engineer and Director of Research at Picker Ultrasound, Elscint, Interspec, and ATL. He is currently working on beamformer architectures and algorithms at GE Corporate Research and Development in Schenectady, NY. He has been involved with several aspects of ultrasound systems development including synthetic aperture arrays, Doppler processing, and the study of thermal bioeffects. Dr. Thomenius is a Fellow of the American Institute of Ultrasound in Medicine, and a member of the IEEE, the American Society of Echocardiography, and the American Association of Physicists in Medicine. Wayne Rigby (M 93) received the B.S. in physics from Yale University in 1979 and the Ph.D. in physics from Stanford University in From 1986 to 1989 he was a postdoctoral scholar at Stanford University, working on a NASA space shuttle experiment. Since 1989 he has worked at GE Corporate Research and Development in Schenectady, NY. His interests include digital beamforming, especially adaptive beamforming for medical ultrasound imaging. Dr. Rigby is a member of the IEEE and the American Physical Society.

COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES

COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES Paper presented at the 23rd Acoustical Imaging Symposium, Boston, Massachusetts, USA, April 13-16, 1997: COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES Jørgen Arendt Jensen and Peter

More information

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming Ultrasound Bioinstrumentation Topic 2 (lecture 3) Beamforming Angular Spectrum 2D Fourier transform of aperture Angular spectrum Propagation of Angular Spectrum Propagation as a Linear Spatial Filter Free

More information

SIMULATION OF B-SCAN IMAGES FROM TWO-DIMENSIONAL TRANSDUCER ARRAYS: PART II - COMPARISONS BETWEEN LINEAR AND TWO-DIMENSIONALPHASED ARRAYS

SIMULATION OF B-SCAN IMAGES FROM TWO-DIMENSIONAL TRANSDUCER ARRAYS: PART II - COMPARISONS BETWEEN LINEAR AND TWO-DIMENSIONALPHASED ARRAYS ULTRASONIC IMAGING 14, 344-353 (1992) SIMULATION OF B-SCAN IMAGES FROM TWO-DIMENSIONAL TRANSDUCER ARRAYS: PART II - COMPARISONS BETWEEN LINEAR AND TWO-DIMENSIONALPHASED ARRAYS Daniel H. Turnbull and F.

More information

Virtual ultrasound sources

Virtual ultrasound sources CHAPTER SEVEN Virtual ultrasound sources One of the drawbacks of the generic synthetic aperture, the synthetic transmit aperture, and recursive ultrasound imaging is the low signal-to-noise ratio (SNR)

More information

Reconfigurable Arrays for Portable Ultrasound

Reconfigurable Arrays for Portable Ultrasound Reconfigurable Arrays for Portable Ultrasound R. Fisher, K. Thomenius, R. Wodnicki, R. Thomas, S. Cogan, C. Hazard, W. Lee, D. Mills GE Global Research Niskayuna, NY-USA fisher@crd.ge.com B. Khuri-Yakub,

More information

Linear arrays used in ultrasonic evaluation

Linear arrays used in ultrasonic evaluation Annals of the University of Craiova, Mathematics and Computer Science Series Volume 38(1), 2011, Pages 54 61 ISSN: 1223-6934 Linear arrays used in ultrasonic evaluation Laura-Angelica Onose and Luminita

More information

An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array

An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array S. Mondal London South Bank University; School of Engineering 103 Borough Road, London SE1 0AA More info about this article: http://www.ndt.net/?id=19093

More information

Exercise 2: Simulation of ultrasound field using Field II

Exercise 2: Simulation of ultrasound field using Field II Exercise 2: Simulation of ultrasound field using Field II The purposes of this exercise is to learn how to: Set up the simulation environment and model a transducer in Field II o Single element transducer

More information

REAL-TIME B-SCAN ULTRASONIC IMAGING USING A DIGITAL PHASED. Robert Dunki-Jacobs and Lewis Thomas General Electric Company Schenectady, New York, 12301

REAL-TIME B-SCAN ULTRASONIC IMAGING USING A DIGITAL PHASED. Robert Dunki-Jacobs and Lewis Thomas General Electric Company Schenectady, New York, 12301 REAL-TIME B-SCAN ULTRASONIC IMAGING USING A DIGITAL PHASED ARRAY SYSTEM FOR NDE Robert Dunki-Jacobs and Lewis Thomas General Electric Company Schenectady, New York, 12301 INTRODUCTION Phased array systems

More information

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI ARCHIVES OF ACOUSTICS 33, 4, 573 580 (2008) LABORATORY SETUP FOR SYNTHETIC APERTURE ULTRASOUND IMAGING Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI Institute of Fundamental Technological Research Polish

More information

Ultrasonic Linear Array Medical Imaging System

Ultrasonic Linear Array Medical Imaging System Ultrasonic Linear Array Medical Imaging System R. K. Saha, S. Karmakar, S. Saha, M. Roy, S. Sarkar and S.K. Sen Microelectronics Division, Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Kolkata-700064.

More information

A COST-EFFECTIVE METHOD FOR ULTRASOUND VOLUMETRIC IMAGING

A COST-EFFECTIVE METHOD FOR ULTRASOUND VOLUMETRIC IMAGING Mathematical & Computational Applications, Voll, No. 2,pp 127-132, 1996 Association for Scientific ReseardJ. A COST-EFFECTIVE METHOD FOR ULTRASOUND VOLUMETRIC IMAGING F. Nazan Urar * and Mustafa Karaman

More information

Ultrasound Miniaturization

Ultrasound Miniaturization Ultrasound Miniaturization Scott Smith Ultrasound Probes Lab Clinical Systems and Devices GE Global Research 2011 Joint AAPM / COMP Meeting July 31-August 4 Vancouver 1 Acknowledgements Charles Baumgartner

More information

Retrospective Transmit Beamformation. Whitepaper. ACUSON SC2000 Volume Imaging Ultrasound System. Answers for life.

Retrospective Transmit Beamformation. Whitepaper. ACUSON SC2000 Volume Imaging Ultrasound System. Answers for life. Whitepaper Retrospective Transmit Beamformation ACUSON SC2000 Volume Imaging Ultrasound System Chuck Bradley, Ph.D. Siemens Healthcare Sector Ultrasound Business Unit Mountain View, California USA Answers

More information

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions. Lesson 06: Pulse-echo Imaging and Display Modes These lessons contain 26 slides plus 15 multiple-choice questions. These lesson were derived from pages 26 through 32 in the textbook: ULTRASOUND IMAGING

More information

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl Ultrasound Beamforming and Image Formation Jeremy J. Dahl Overview Ultrasound Concepts Beamforming Image Formation Absorption and TGC Advanced Beamforming Techniques Synthetic Receive Aperture Parallel

More information

Further development of synthetic aperture real-time 3D scanning with a rotating phased array

Further development of synthetic aperture real-time 3D scanning with a rotating phased array Downloaded from orbit.dtu.dk on: Dec 17, 217 Further development of synthetic aperture real-time 3D scanning with a rotating phased array Nikolov, Svetoslav; Tomov, Borislav Gueorguiev; Gran, Fredrik;

More information

Random Thinning of Segmented Annular Arrrays

Random Thinning of Segmented Annular Arrrays Random Thinning of Segmented Annular Arrrays G. Godoy a, O. Martínez b, A. Ibañez b, L.G. Ullate b a E.U.P. de Linares, Universidad de Jaén, 237 Linares - Jaén, Spain b Instituto de Automática Industrial-CSIC,

More information

Medical Imaging (EL582/BE620/GA4426)

Medical Imaging (EL582/BE620/GA4426) Medical Imaging (EL582/BE620/GA4426) Jonathan Mamou, PhD Riverside Research Lizzi Center for Biomedical Engineering New York, NY jmamou@riversideresearch.org On behalf of Prof. Daniel Turnbull Outline

More information

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS T. Stepinski P. Wu Uppsala University Signals and Systems P.O. Box 528, SE- 75 2 Uppsala Sweden ULTRASONIC IMAGING of COPPER MATERIAL USING

More information

IF ONE OR MORE of the antennas in a wireless communication

IF ONE OR MORE of the antennas in a wireless communication 1976 IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, VOL. 52, NO. 8, AUGUST 2004 Adaptive Crossed Dipole Antennas Using a Genetic Algorithm Randy L. Haupt, Fellow, IEEE Abstract Antenna misalignment in

More information

CLAUDIO TALARICO Department of Electrical and Computer Engineering Gonzaga University Spokane, WA ITALY

CLAUDIO TALARICO Department of Electrical and Computer Engineering Gonzaga University Spokane, WA ITALY Comprehensive study on the role of the phase distribution on the performances of the phased arrays systems based on a behavior mathematical model GIUSEPPE COVIELLO, GIANFRANCO AVITABILE, GIOVANNI PICCINNI,

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION Spatial resolution in ultrasonic imaging is one of many parameters that impact image quality. Therefore, mechanisms to improve system spatial resolution could result in improved

More information

Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging Ihor Trots, Yuriy Tasinkevych, Andrzej Nowicki and Marcin Lewandowski

Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging Ihor Trots, Yuriy Tasinkevych, Andrzej Nowicki and Marcin Lewandowski Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging Ihor Trots, Yuriy Tasinkevych, Andrzej Nowicki and Marcin Lewandowski Abstract The paper presents the multi-element synthetic

More information

Effects on phased arrays radiation pattern due to phase error distribution in the phase shifter operation

Effects on phased arrays radiation pattern due to phase error distribution in the phase shifter operation Effects on phased arrays radiation pattern due to phase error distribution in the phase shifter operation Giuseppe Coviello 1,a, Gianfranco Avitabile 1,Giovanni Piccinni 1, Giulio D Amato 1, Claudio Talarico

More information

DESIGN OF GLOBAL SAW RFID TAG DEVICES C. S. Hartmann, P. Brown, and J. Bellamy RF SAW, Inc., 900 Alpha Drive Ste 400, Richardson, TX, U.S.A.

DESIGN OF GLOBAL SAW RFID TAG DEVICES C. S. Hartmann, P. Brown, and J. Bellamy RF SAW, Inc., 900 Alpha Drive Ste 400, Richardson, TX, U.S.A. DESIGN OF GLOBAL SAW RFID TAG DEVICES C. S. Hartmann, P. Brown, and J. Bellamy RF SAW, Inc., 900 Alpha Drive Ste 400, Richardson, TX, U.S.A., 75081 Abstract - The Global SAW Tag [1] is projected to be

More information

3. Ultrasound Imaging(2)

3. Ultrasound Imaging(2) 3. Ultrasound Imaging(2) Lecture 13, 14 Medical Imaging Systems Jae Gwan Kim, Ph.D. jaekim@gist.ac.kr, X 2220 Department of BioMedical Science and Engineering Gwangju Institute of Sciences and Technology

More information

Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors

Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors Derek Puccio, Don Malocha, Nancy Saldanha Department of Electrical and Computer Engineering University of Central Florida

More information

ENHANCEMENT OF SYNTHETIC APERTURE FOCUSING TECHNIQUE (SAFT) BY ADVANCED SIGNAL PROCESSING

ENHANCEMENT OF SYNTHETIC APERTURE FOCUSING TECHNIQUE (SAFT) BY ADVANCED SIGNAL PROCESSING ENHANCEMENT OF SYNTHETIC APERTURE FOCUSING TECHNIQUE (SAFT) BY ADVANCED SIGNAL PROCESSING M. Jastrzebski, T. Dusatko, J. Fortin, F. Farzbod, A.N. Sinclair; University of Toronto, Toronto, Canada; M.D.C.

More information

Proceedings of Meetings on Acoustics

Proceedings of Meetings on Acoustics Proceedings of Meetings on Acoustics Volume 19, 2013 http://acousticalsociety.org/ ICA 2013 Montreal Montreal, Canada 2-7 June 2013 Signal Processing in Acoustics Session 4aSP: Sensor Array Beamforming

More information

Introduction to Radar Systems. Radar Antennas. MIT Lincoln Laboratory. Radar Antennas - 1 PRH 6/18/02

Introduction to Radar Systems. Radar Antennas. MIT Lincoln Laboratory. Radar Antennas - 1 PRH 6/18/02 Introduction to Radar Systems Radar Antennas Radar Antennas - 1 Disclaimer of Endorsement and Liability The video courseware and accompanying viewgraphs presented on this server were prepared as an account

More information

12/26/2017. Alberto Ardon M.D.

12/26/2017. Alberto Ardon M.D. Alberto Ardon M.D. 1 Preparatory Work Ultrasound Physics http://www.nysora.com/mobile/regionalanesthesia/foundations-of-us-guided-nerve-blockstechniques/index.1.html Basic Ultrasound Handling https://www.youtube.com/watch?v=q2otukhrruc

More information

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia M R I Physics Course Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia M R I Physics Course Magnetic Resonance Imaging Spatial

More information

A K-Band Flat Transmitarray Antenna with a Planar Microstrip Slot-Fed Patch Antenna Feeder

A K-Band Flat Transmitarray Antenna with a Planar Microstrip Slot-Fed Patch Antenna Feeder Progress In Electromagnetics Research C, Vol. 64, 97 104, 2016 A K-Band Flat Transmitarray Antenna with a Planar Microstrip Slot-Fed Patch Antenna Feeder Lv-Wei Chen and Yuehe Ge * Abstract A thin phase-correcting

More information

A DUAL-RECEIVER METHOD FOR SIMULTANEOUS MEASUREMENTS OF RADOME TRANSMISSION EFFICIENCY AND BEAM DEFLECTION

A DUAL-RECEIVER METHOD FOR SIMULTANEOUS MEASUREMENTS OF RADOME TRANSMISSION EFFICIENCY AND BEAM DEFLECTION A DUAL-RECEIVER METHOD FOR SIMULTANEOUS MEASUREMENTS OF RADOME TRANSMISSION EFFICIENCY AND BEAM DEFLECTION Robert Luna MI Technologies, 4500 River Green Parkway, Suite 200 Duluth, GA 30096 rluna@mi-technologies.com

More information

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa. Joanna X.Qiao 1, Matthias Jobst 2

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa. Joanna X.Qiao 1, Matthias Jobst 2 8th World Conference on ondestructive Testing, 6-0 April 0, Durban, outh Africa An Adaptive Phased-Array Imaging ethod for Ultrasonic Testing Joanna X.Qiao, atthias Jobst GE Inspection Technologies; 50

More information

Understanding How Frequency, Beam Patterns of Transducers, and Reflection Characteristics of Targets Affect the Performance of Ultrasonic Sensors

Understanding How Frequency, Beam Patterns of Transducers, and Reflection Characteristics of Targets Affect the Performance of Ultrasonic Sensors Characteristics of Targets Affect the Performance of Ultrasonic Sensors By Donald P. Massa, President and CTO of Massa Products Corporation Overview of How an Ultrasonic Sensor Functions Ultrasonic sensors

More information

INSTRUMENTATION DESIGN FOR ULTRASONIC IMAGING

INSTRUMENTATION DESIGN FOR ULTRASONIC IMAGING Source: STANDARD HANDBOOK OF BIOMEDICAL ENGINEERING AND DESIGN CHAPTER 25 INSTRUMENTATION DESIGN FOR ULTRASONIC IMAGING Kai E. Thomenius GE Corporate Research and Development, Schenectady, New York 25.1

More information

SIGNAL PROCESSING ALGORITHMS FOR HIGH-PRECISION NAVIGATION AND GUIDANCE FOR UNDERWATER AUTONOMOUS SENSING SYSTEMS

SIGNAL PROCESSING ALGORITHMS FOR HIGH-PRECISION NAVIGATION AND GUIDANCE FOR UNDERWATER AUTONOMOUS SENSING SYSTEMS SIGNAL PROCESSING ALGORITHMS FOR HIGH-PRECISION NAVIGATION AND GUIDANCE FOR UNDERWATER AUTONOMOUS SENSING SYSTEMS Daniel Doonan, Chris Utley, and Hua Lee Imaging Systems Laboratory Department of Electrical

More information

The Basics of Patch Antennas, Updated

The Basics of Patch Antennas, Updated The Basics of Patch Antennas, Updated By D. Orban and G.J.K. Moernaut, Orban Microwave Products www.orbanmicrowave.com Introduction This article introduces the basic concepts of patch antennas. We use

More information

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล Diagnosis TTE TEE ICE 3D 4D Evaluation of Cardiac Anatomy Hemodynamic

More information

Electronically Steerable planer Phased Array Antenna

Electronically Steerable planer Phased Array Antenna Electronically Steerable planer Phased Array Antenna Amandeep Kaur Department of Electronics and Communication Technology, Guru Nanak Dev University, Amritsar, India Abstract- A planar phased-array antenna

More information

ECHO-CANCELLATION IN A SINGLE-TRANSDUCER ULTRASONIC IMAGING SYSTEM

ECHO-CANCELLATION IN A SINGLE-TRANSDUCER ULTRASONIC IMAGING SYSTEM ECHO-CANCELLATION IN A SINGLE-TRANSDUCER ULTRASONIC IMAGING SYSTEM Johan Carlson a,, Frank Sjöberg b, Nicolas Quieffin c, Ros Kiri Ing c, and Stéfan Catheline c a EISLAB, Dept. of Computer Science and

More information

Keywords: cylindrical near-field acquisition, mechanical and electrical errors, uncertainty, directivity.

Keywords: cylindrical near-field acquisition, mechanical and electrical errors, uncertainty, directivity. UNCERTAINTY EVALUATION THROUGH SIMULATIONS OF VIRTUAL ACQUISITIONS MODIFIED WITH MECHANICAL AND ELECTRICAL ERRORS IN A CYLINDRICAL NEAR-FIELD ANTENNA MEASUREMENT SYSTEM S. Burgos, M. Sierra-Castañer, F.

More information

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE DOYOUN KIM, YOUNHO CHO * and JOONHYUN LEE Graduate School of Mechanical Engineering, Pusan National University Jangjeon-dong,

More information

Simulation of advanced ultrasound systems using Field II

Simulation of advanced ultrasound systems using Field II Downloaded from orbit.dtu.dk on: Jul 16, 218 Simulation of advanced ultrasound systems using Field II Jensen, Jørgen Arendt Published in: IEEE International Symposium on Biomedical Engineering 24 Link

More information

RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE

RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE D. MacLauchlan, S. Clark, B. Cox, T. Doyle, B. Grimmett, J. Hancock, K. Hour, C. Rutherford BWXT Services, Non Destructive Evaluation and Inspection

More information

FOURIER analysis is a well-known method for nonparametric

FOURIER analysis is a well-known method for nonparametric 386 IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 54, NO. 1, FEBRUARY 2005 Resonator-Based Nonparametric Identification of Linear Systems László Sujbert, Member, IEEE, Gábor Péceli, Fellow,

More information

LE/ESSE Payload Design

LE/ESSE Payload Design LE/ESSE4360 - Payload Design 4.3 Communications Satellite Payload - Hardware Elements Earth, Moon, Mars, and Beyond Dr. Jinjun Shan, Professor of Space Engineering Department of Earth and Space Science

More information

PRIME FOCUS FEEDS FOR THE COMPACT RANGE

PRIME FOCUS FEEDS FOR THE COMPACT RANGE PRIME FOCUS FEEDS FOR THE COMPACT RANGE John R. Jones Prime focus fed paraboloidal reflector compact ranges are used to provide plane wave illumination indoors at small range lengths for antenna and radar

More information

EQUIVALENT THROAT TECHNOLOGY

EQUIVALENT THROAT TECHNOLOGY EQUIVALENT THROAT TECHNOLOGY Modern audio frequency reproduction systems use transducers to convert electrical energy to acoustical energy. Systems used for the reinforcement of speech and music are referred

More information

Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D

Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D DINFO Dipartimento di Ingegneria dell Informazione Department of Information Engineering Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D Piero Tortoli Microelectronics Systems Design Lab 1 Introduction

More information

INSPECTION OF THERMAL BARRIERS OF PRIMARY PUMPS WITH PHASED ARRAY PROBE AND PIEZOCOMPOSITE TECHNOLOGY

INSPECTION OF THERMAL BARRIERS OF PRIMARY PUMPS WITH PHASED ARRAY PROBE AND PIEZOCOMPOSITE TECHNOLOGY INSPECTION OF THERMAL BARRIERS OF PRIMARY PUMPS WITH PHASED ARRAY PROBE AND PIEZOCOMPOSITE TECHNOLOGY J. Poguet Imasonic S.A. France E. Abittan EDF-GDL France Abstract In order to meet the requirements

More information

Application Note: Sidescan Sonar Beamwidth.

Application Note: Sidescan Sonar Beamwidth. Application Note: Sidescan Sonar Beamwidth. The Beamwidth of a sidescanning sonar is often defined or stated in terms of a beam angle. However the beam shape of a sidescanning sonar is not, a) a simple

More information

Mathematical Modeling of Ultrasonic Phased Array for Obstacle Location for Visually Impaired

Mathematical Modeling of Ultrasonic Phased Array for Obstacle Location for Visually Impaired IOSR Journal of VLSI and Signal Processing (IOSR-JVSP) Volume 2, Issue 6 (Jul. Aug. 2013), PP 52-56 e-issn: 2319 4200, p-issn No. : 2319 4197 Mathematical Modeling of Ultrasonic Phased Array for Obstacle

More information

Advances in Antenna Measurement Instrumentation and Systems

Advances in Antenna Measurement Instrumentation and Systems Advances in Antenna Measurement Instrumentation and Systems Steven R. Nichols, Roger Dygert, David Wayne MI Technologies Suwanee, Georgia, USA Abstract Since the early days of antenna pattern recorders,

More information

Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin

Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin film is characterized by using an optical profiler (Bruker ContourGT InMotion). Inset: 3D optical

More information

COUPLED SECTORIAL LOOP ANTENNA (CSLA) FOR ULTRA-WIDEBAND APPLICATIONS *

COUPLED SECTORIAL LOOP ANTENNA (CSLA) FOR ULTRA-WIDEBAND APPLICATIONS * COUPLED SECTORIAL LOOP ANTENNA (CSLA) FOR ULTRA-WIDEBAND APPLICATIONS * Nader Behdad, and Kamal Sarabandi Department of Electrical Engineering and Computer Science University of Michigan, Ann Arbor, MI,

More information

On Determination of Focal Laws for Linear Phased Array Probes as to the Active and Passive Element Size

On Determination of Focal Laws for Linear Phased Array Probes as to the Active and Passive Element Size 19 th World Conference on Non-Destructive Testing 2016 On Determination of Focal Laws for Linear Phased Array Probes as to the Active and Passive Element Size Andreas GOMMLICH 1, Frank SCHUBERT 2 1 Institute

More information

A Low-Profile Planar Monopole Antenna for Multiband Operation of Mobile Handsets

A Low-Profile Planar Monopole Antenna for Multiband Operation of Mobile Handsets IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, VOL. 51, NO. 1, JANUARY 2003 121 A Low-Profile Planar Monopole Antenna for Multiband Operation of Mobile Handsets Kin-Lu Wong, Senior Member, IEEE, Gwo-Yun

More information

A Modified Synthetic Aperture Focussing Technique Utilising the Spatial Impulse Response of the Ultrasound Transducer

A Modified Synthetic Aperture Focussing Technique Utilising the Spatial Impulse Response of the Ultrasound Transducer A Modified Synthetic Aperture Focussing Technique Utilising the Spatial Impulse Response of the Ultrasound Transducer Stephen A. MOSEY 1, Peter C. CHARLTON 1, Ian WELLS 1 1 Faculty of Applied Design and

More information

Full-Wave Analysis of Planar Reflectarrays with Spherical Phase Distribution for 2-D Beam-Scanning using FEKO Electromagnetic Software

Full-Wave Analysis of Planar Reflectarrays with Spherical Phase Distribution for 2-D Beam-Scanning using FEKO Electromagnetic Software Full-Wave Analysis of Planar Reflectarrays with Spherical Phase Distribution for 2-D Beam-Scanning using FEKO Electromagnetic Software Payam Nayeri 1, Atef Z. Elsherbeni 1, and Fan Yang 1,2 1 Center of

More information

Standard Guide for Evaluating Performance Characteristics of Phased-Array Ultrasonic Testing Instruments and Systems 1

Standard Guide for Evaluating Performance Characteristics of Phased-Array Ultrasonic Testing Instruments and Systems 1 Designation: E2491 08 Standard Guide for Evaluating Performance Characteristics of Phased-Array Ultrasonic Testing Instruments and Systems 1 This standard is issued under the fixed designation E2491; the

More information

A NEW WIDEBAND DUAL LINEAR FEED FOR PRIME FOCUS COMPACT RANGES

A NEW WIDEBAND DUAL LINEAR FEED FOR PRIME FOCUS COMPACT RANGES A NEW WIDEBAND DUAL LINEAR FEED FOR PRIME FOCUS COMPACT RANGES by Ray Lewis and James H. Cook, Jr. ABSTRACT Performance trade-offs are Investigated between the use of clustered waveguide bandwidth feeds

More information

ANTENNA INTRODUCTION / BASICS

ANTENNA INTRODUCTION / BASICS ANTENNA INTRODUCTION / BASICS RULES OF THUMB: 1. The Gain of an antenna with losses is given by: 2. Gain of rectangular X-Band Aperture G = 1.4 LW L = length of aperture in cm Where: W = width of aperture

More information

CHAPTER 2 MICROSTRIP REFLECTARRAY ANTENNA AND PERFORMANCE EVALUATION

CHAPTER 2 MICROSTRIP REFLECTARRAY ANTENNA AND PERFORMANCE EVALUATION 43 CHAPTER 2 MICROSTRIP REFLECTARRAY ANTENNA AND PERFORMANCE EVALUATION 2.1 INTRODUCTION This work begins with design of reflectarrays with conventional patches as unit cells for operation at Ku Band in

More information

UNIVERSITY OF OSLO. ultrasound imaging. Sverre Holm DEPARTMENT OF INFORMATICS

UNIVERSITY OF OSLO. ultrasound imaging. Sverre Holm DEPARTMENT OF INFORMATICS High-resolution beamforming in ultrasound imaging Sverre Holm DEPARTMENT OF INFORMATICS MEDT8007 Simulation Methods in Ultrasound Imaging - NTNU Sverre Holm DEPARTMENT OF INFORMATICS Journal Publications

More information

Ultra-wideband Omnidirectional Conformable Low-Profile Mode-0 Spiral-Mode Microstrip (SMM) Antenna

Ultra-wideband Omnidirectional Conformable Low-Profile Mode-0 Spiral-Mode Microstrip (SMM) Antenna Copyright Notice: 2005 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works

More information

COMPARATIVE ANALYSIS BETWEEN CONICAL AND GAUSSIAN PROFILED HORN ANTENNAS

COMPARATIVE ANALYSIS BETWEEN CONICAL AND GAUSSIAN PROFILED HORN ANTENNAS Progress In Electromagnetics Research, PIER 38, 147 166, 22 COMPARATIVE ANALYSIS BETWEEN CONICAL AND GAUSSIAN PROFILED HORN ANTENNAS A. A. Kishk and C.-S. Lim Department of Electrical Engineering The University

More information

Performance Analysis on Beam-steering Algorithm for Parametric Array Loudspeaker Application

Performance Analysis on Beam-steering Algorithm for Parametric Array Loudspeaker Application (283 -- 917) Proceedings of the 3rd (211) CUTSE International Conference Miri, Sarawak, Malaysia, 8-9 Nov, 211 Performance Analysis on Beam-steering Algorithm for Parametric Array Loudspeaker Application

More information

ADVANCED 14/12 AND 30/20 GHz MULTIPLE BEAM ANTENNA TECHNOLOGY FOR COMMUNICATIONS SATELLITES

ADVANCED 14/12 AND 30/20 GHz MULTIPLE BEAM ANTENNA TECHNOLOGY FOR COMMUNICATIONS SATELLITES ADVANCED 14/12 AND 30/20 GHz MULTIPLE BEAM ANTENNA TECHNOLOGY FOR COMMUNICATIONS SATELLITES C.C. Chen TRW Defense and Space Systems Group Redondo Beach, CA 90278 ABSTRACT This paper discusses recent TRW

More information

A Terrestrial Multiple-Receiver Radio Link Experiment at 10.7 GHz - Comparisons of Results with Parabolic Equation Calculations

A Terrestrial Multiple-Receiver Radio Link Experiment at 10.7 GHz - Comparisons of Results with Parabolic Equation Calculations RADIOENGINEERING, VOL. 19, NO. 1, APRIL 2010 117 A Terrestrial Multiple-Receiver Radio Link Experiment at 10.7 GHz - Comparisons of Results with Parabolic Equation Calculations Pavel VALTR 1, Pavel PECHAC

More information

Effects of snaking for a towed sonar array on an AUV

Effects of snaking for a towed sonar array on an AUV Lorentzen, Ole J., Effects of snaking for a towed sonar array on an AUV, Proceedings of the 38 th Scandinavian Symposium on Physical Acoustics, Geilo February 1-4, 2015. Editor: Rolf J. Korneliussen, ISBN

More information

ANECHOIC CHAMBER DIAGNOSTIC IMAGING

ANECHOIC CHAMBER DIAGNOSTIC IMAGING ANECHOIC CHAMBER DIAGNOSTIC IMAGING Greg Hindman Dan Slater Nearfield Systems Incorporated 1330 E. 223rd St. #524 Carson, CA 90745 USA (310) 518-4277 Abstract Traditional techniques for evaluating the

More information

A TECHNIQUE TO EVALUATE THE IMPACT OF FLEX CABLE PHASE INSTABILITY ON mm-wave PLANAR NEAR-FIELD MEASUREMENT ACCURACIES

A TECHNIQUE TO EVALUATE THE IMPACT OF FLEX CABLE PHASE INSTABILITY ON mm-wave PLANAR NEAR-FIELD MEASUREMENT ACCURACIES A TECHNIQUE TO EVALUATE THE IMPACT OF FLEX CABLE PHASE INSTABILITY ON mm-wave PLANAR NEAR-FIELD MEASUREMENT ACCURACIES Daniël Janse van Rensburg Nearfield Systems Inc., 133 E, 223rd Street, Bldg. 524,

More information

ANTENNA THEORY. Analysis and Design. CONSTANTINE A. BALANIS Arizona State University. JOHN WILEY & SONS New York Chichester Brisbane Toronto Singapore

ANTENNA THEORY. Analysis and Design. CONSTANTINE A. BALANIS Arizona State University. JOHN WILEY & SONS New York Chichester Brisbane Toronto Singapore ANTENNA THEORY Analysis and Design CONSTANTINE A. BALANIS Arizona State University JOHN WILEY & SONS New York Chichester Brisbane Toronto Singapore Contents Preface xv Chapter 1 Antennas 1 1.1 Introduction

More information

DIGITAL BEAM-FORMING ANTENNA OPTIMIZATION FOR REFLECTOR BASED SPACE DEBRIS RADAR SYSTEM

DIGITAL BEAM-FORMING ANTENNA OPTIMIZATION FOR REFLECTOR BASED SPACE DEBRIS RADAR SYSTEM DIGITAL BEAM-FORMING ANTENNA OPTIMIZATION FOR REFLECTOR BASED SPACE DEBRIS RADAR SYSTEM A. Patyuchenko, M. Younis, G. Krieger German Aerospace Center (DLR), Microwaves and Radar Institute, Muenchner Strasse

More information

Chapter 5. Array of Star Spirals

Chapter 5. Array of Star Spirals Chapter 5. Array of Star Spirals The star spiral was introduced in the previous chapter and it compared well with the circular Archimedean spiral. This chapter will examine the star spiral in an array

More information

Module 2 WAVE PROPAGATION (Lectures 7 to 9)

Module 2 WAVE PROPAGATION (Lectures 7 to 9) Module 2 WAVE PROPAGATION (Lectures 7 to 9) Lecture 9 Topics 2.4 WAVES IN A LAYERED BODY 2.4.1 One-dimensional case: material boundary in an infinite rod 2.4.2 Three dimensional case: inclined waves 2.5

More information

Beamforming Techniques for Smart Antenna using Rectangular Array Structure

Beamforming Techniques for Smart Antenna using Rectangular Array Structure International Journal of Electrical and Computer Engineering (IJECE) Vol. 4, No. 2, April 2014, pp. 257~264 ISSN: 2088-8708 257 Beamforming Techniques for Smart Antenna using Rectangular Array Structure

More information

FPGA-BASED CONTROL SYSTEM OF AN ULTRASONIC PHASED ARRAY

FPGA-BASED CONTROL SYSTEM OF AN ULTRASONIC PHASED ARRAY The 10 th International Conference of the Slovenian Society for Non-Destructive Testing»Application of Contemporary Non-Destructive Testing in Engineering«September 1-3, 009, Ljubljana, Slovenia, 77-84

More information

DESIGN OF PRINTED YAGI ANTENNA WITH ADDI- TIONAL DRIVEN ELEMENT FOR WLAN APPLICA- TIONS

DESIGN OF PRINTED YAGI ANTENNA WITH ADDI- TIONAL DRIVEN ELEMENT FOR WLAN APPLICA- TIONS Progress In Electromagnetics Research C, Vol. 37, 67 81, 013 DESIGN OF PRINTED YAGI ANTENNA WITH ADDI- TIONAL DRIVEN ELEMENT FOR WLAN APPLICA- TIONS Jafar R. Mohammed * Communication Engineering Department,

More information

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound Ultrasound Physics History: Ultrasound Ultrasound 1942: Dr. Karl Theodore Dussik transmission ultrasound investigation of the brain 1949-51: Holmes and Howry subject submerged in water tank to achieve

More information

Real Time Deconvolution of In-Vivo Ultrasound Images

Real Time Deconvolution of In-Vivo Ultrasound Images Paper presented at the IEEE International Ultrasonics Symposium, Prague, Czech Republic, 3: Real Time Deconvolution of In-Vivo Ultrasound Images Jørgen Arendt Jensen Center for Fast Ultrasound Imaging,

More information

AN ALTERNATIVE METHOD FOR DIFFERENCE PATTERN FORMATION IN MONOPULSE ANTENNA

AN ALTERNATIVE METHOD FOR DIFFERENCE PATTERN FORMATION IN MONOPULSE ANTENNA Progress In Electromagnetics Research Letters, Vol. 42, 45 54, 213 AN ALTERNATIVE METHOD FOR DIFFERENCE PATTERN FORMATION IN MONOPULSE ANTENNA Jafar R. Mohammed * Communication Engineering Department,

More information

A SHEAR WAVE TRANSDUCER ARRAY FOR REAL-TIME IMAGING. R.L. Baer and G.S. Kino. Edward L. Ginzton Laboratory Stanford University Stanford, CA 94305

A SHEAR WAVE TRANSDUCER ARRAY FOR REAL-TIME IMAGING. R.L. Baer and G.S. Kino. Edward L. Ginzton Laboratory Stanford University Stanford, CA 94305 A SHEAR WAVE TRANSDUCER ARRAY FOR REAL-TIME IMAGING R.L. Baer and G.S. Kino Edward L. Ginzton Laboratory Stanford University Stanford, CA 94305 INTRODUCTION In this paper we describe a contacting shear

More information

Antenna Fundamentals Basics antenna theory and concepts

Antenna Fundamentals Basics antenna theory and concepts Antenna Fundamentals Basics antenna theory and concepts M. Haridim Brno University of Technology, Brno February 2017 1 Topics What is antenna Antenna types Antenna parameters: radiation pattern, directivity,

More information

Simulation and design of a microphone array for beamforming on a moving acoustic source

Simulation and design of a microphone array for beamforming on a moving acoustic source Simulation and design of a microphone array for beamforming on a moving acoustic source Dick Petersen and Carl Howard School of Mechanical Engineering, University of Adelaide, South Australia, Australia

More information

Performance Factors. Technical Assistance. Fundamental Optics

Performance Factors.   Technical Assistance. Fundamental Optics Performance Factors After paraxial formulas have been used to select values for component focal length(s) and diameter(s), the final step is to select actual lenses. As in any engineering problem, this

More information

Accuracy Estimation of Microwave Holography from Planar Near-Field Measurements

Accuracy Estimation of Microwave Holography from Planar Near-Field Measurements Accuracy Estimation of Microwave Holography from Planar Near-Field Measurements Christopher A. Rose Microwave Instrumentation Technologies River Green Parkway, Suite Duluth, GA 9 Abstract Microwave holography

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION A full-parameter unidirectional metamaterial cloak for microwaves Bilinear Transformations Figure 1 Graphical depiction of the bilinear transformation and derived material parameters. (a) The transformation

More information

Monoconical RF Antenna

Monoconical RF Antenna Page 1 of 8 RF and Microwave Models : Monoconical RF Antenna Monoconical RF Antenna Introduction Conical antennas are useful for many applications due to their broadband characteristics and relative simplicity.

More information

a a ULTRASONICS SYMPOSIUM HYPERTHERMIA TREATMENT JJLTRASOUN D PHASED ARRAYS

a a ULTRASONICS SYMPOSIUM HYPERTHERMIA TREATMENT JJLTRASOUN D PHASED ARRAYS JJLTRASOUN D PHASED ARRAYS HYPERTHERMIA TREATMENT L. A. Frizzell, P. J. Benkeser, K. B. Ocheltree, and C. A. Cain Bioacoustics Research Laboratory, University of 1406 W. Green St., Urbana, IL 61801 Illinois,

More information

Direction of Arrival Estimation in Smart Antenna for Marine Communication. Deepthy M Vijayan, Sreedevi K Menon /16/$31.

Direction of Arrival Estimation in Smart Antenna for Marine Communication. Deepthy M Vijayan, Sreedevi K Menon /16/$31. International Conference on Communication and Signal Processing, April 6-8, 2016, India Direction of Arrival Estimation in Smart Antenna for Marine Communication Deepthy M Vijayan, Sreedevi K Menon Abstract

More information

Mutually Optimizing Resolution Enhancement Techniques: Illumination, APSM, Assist Feature OPC, and Gray Bars

Mutually Optimizing Resolution Enhancement Techniques: Illumination, APSM, Assist Feature OPC, and Gray Bars Mutually Optimizing Resolution Enhancement Techniques: Illumination, APSM, Assist Feature OPC, and Gray Bars Bruce W. Smith Rochester Institute of Technology, Microelectronic Engineering Department, 82

More information

Radar Equations. for Modern Radar. David K. Barton ARTECH HOUSE BOSTON LONDON. artechhouse.com

Radar Equations. for Modern Radar. David K. Barton ARTECH HOUSE BOSTON LONDON. artechhouse.com Radar Equations for Modern Radar David K Barton ARTECH HOUSE BOSTON LONDON artechhousecom Contents Preface xv Chapter 1 Development of the Radar Equation 1 11 Radar Equation Fundamentals 1 111 Maximum

More information

Chapter 2. Fundamental Properties of Antennas. ECE 5318/6352 Antenna Engineering Dr. Stuart Long

Chapter 2. Fundamental Properties of Antennas. ECE 5318/6352 Antenna Engineering Dr. Stuart Long Chapter Fundamental Properties of Antennas ECE 5318/635 Antenna Engineering Dr. Stuart Long 1 IEEE Standards Definition of Terms for Antennas IEEE Standard 145-1983 IEEE Transactions on Antennas and Propagation

More information

Mathematical models for radiodetermination radar systems antenna patterns for use in interference analyses

Mathematical models for radiodetermination radar systems antenna patterns for use in interference analyses Recommendation ITU-R M.1851-1 (1/18) Mathematical models for radiodetermination radar systems antenna patterns for use in interference analyses M Series Mobile, radiodetermination, amateur and related

More information

Data set reduction for ultrasonic TFM imaging using the effective aperture approach and virtual sources

Data set reduction for ultrasonic TFM imaging using the effective aperture approach and virtual sources Journal of Physics: Conference Series OPEN ACCESS Data set reduction for ultrasonic TFM imaging using the effective aperture approach and virtual sources To cite this article: S Bannouf et al 2013 J. Phys.:

More information