Upper and Lower Tear Menisci on Contact Lenses METHODS

Size: px
Start display at page:

Download "Upper and Lower Tear Menisci on Contact Lenses METHODS"

Transcription

1 Upper and Lower Tear Menisci on Contact Lenses Jianhua Wang, 1,2 Ian Cox, 3 and William T. Reindel 3 PURPOSE. The purpose of this study was to measure upper and lower tear menisci on contact lenses using real time optical coherence tomography (OCT). METHODS. Both eyes of 20 adapted contact lens wearers were imaged when they wore two types of silicone hydrogel lenses, balafilcon A on one eye and galyfilcon A on the other eye. The height, radius, and area of upper and lower tear menisci were obtained before, immediately after, and 20 minutes after lens wear on two consecutive days. On a third visit, the lenses were switched between eyes and an investigative lubricant was instilled after 4 hours of lens wear. OCT images were obtained as before and additionally at 1 and 4 hours after lens insertion. Imaging was also conducted immediately after lubricant instillation and 20 minutes postinstillation. RESULTS. There were no significant differences in the measured variables between lenses (P 0.05) and between consecutive visits (P 0.05). The menisci around both eyelids immediately after lens insertion were significantly greater than that before (P 0.005). By 20 minutes after lens insertion, all variables had returned to baseline values and remained that way for at least 4 hours. Immediately after the instillation of the lubricant at 4 hours, meniscus variables increased (P 0.001), but recovery to baseline occurred within 20 minutes. CONCLUSIONS. It is feasible to use OCT in the measurement of both upper and lower tear menisci on contact lenses in situ. Tear menisci increased on insertion of contact lenses and on instillation of lubricants. However baseline values were reestablished with 20 minutes. (Invest Ophthalmol Vis Sci. 2009;50: ) DOI: /iovs Soft contact lenses must remain wet during lens wear so that sharp vision and ocular comfort are maintained. It is very common for soft contact lens wearers to experience dry eye, especially in the afternoon after wearing them for a period of time. 1,2 Dry eye is a common cause for wearers to abandon use of their lenses. 1,2 Changes in tear distribution and dynamics during lens wear remain unknown due to the extreme difficulty of imaging both tear menisci at the same From the 1 Bascom Palmer Eye Institute, University of Miami, Miami, Florida; the 2 Department of Ophthalmology, University of Rochester, Rochester, New York; and 3 Bausch & Lomb, Rochester, New York. Supported by a research grant from Bausch & Lomb (JW) and NEI core center Grant P30 EY Submitted for publication June 20, 2008; revised August 23, 2008; accepted January 13, Disclosure: J. Wang, None; I. Cox, Bausch & Lomb (E); W.T. Reindel, Bausch & Lomb (E) The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked advertisement in accordance with 18 U.S.C solely to indicate this fact. Corresponding author: Jianhua Wang, Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, 1638 NW 10th Avenue, McKnight Building, Room 202, Miami, FL 33136; jwang3@med.miami.edu. time. Thanks to the advancement of real-time imaging and recording with optical coherence tomography (OCT), tear dynamics were successfully imaged recently. 3 Here we used OCT to simultaneously image the tear menisci between contact lenses and the upper and lower eyelids. METHODS Ethics clearance was obtained from the research review board of the University of Rochester. Informed consent was obtained from all participants before enrollment in the study in accordance with the tenets of the Declaration of Helsinki. A total of 20 participants (5 men and 15 women; mean SD age: years) were recruited. All subjects were experienced contact lens wearers and were wearing soft contact lenses before participation in this study. As described previously, 3 the study was conducted in a small consulting room with monitored temperature (15 C 25 C) and humidity (30% 50%). At each subject s screening visit, the contact lens prescription of both eyes was obtained based on the existing prescription and auto-refraction. Two silicone hydrogel lenses were used in this study. They were PureVision (balafilcon A; Bausch & Lomb, Rochester, NY) with base curve 8.6 mm and Acuvue Advance (galyfilcon A; Vistakon, Jacksonville, FL) with base curve 8.3 mm. The diameter of both lenses was 14 mm. Contact lens solution (Opti-Free RepleniSH; Alcon, Fort Worth, TX) was used to soak these study lenses for 8 hours before insertion by subjects for visits one and two. A different contact lens solution (ReNu Multiplus; Bausch & Lomb) was used to soak the lenses for visit three. Lenses from the same lens package were used on the same eye during the first two visits, and the lens from a new package was used for the third visit. During OCT imaging, a vertical scan across the corneal apex was conducted while the subject fixated on an external target and blinked normally. During the first two study visits, the procedure was performed at the same time of day on consecutive days. To enable statistical tests for repeatability of measurements, the Pure- Vision lens was always inserted in the right eye and the Acuvue lens was always inserted in the left eye of each subject on both visits. The choice for right and left eyes was made randomly at the beginning of the study. OCT images (Fig. 1) were obtained at three checkpoints: before, immediately after, and 20 minutes after lens insertion. During the third visit, the lenses were switched between eyes. After wearing the lenses for 4 hours, 35 L of a contact lens rewetting drop (Bausch & Lomb) was instilled into the eye when the lens was in situ. OCT imaging during visit three was conducted before lens wear, immediately after lens insertion, 20 minutes, and 1 and 4 hours after lens insertion. OCT images were also taken immediately after the instillation of the lubricant and 20 minutes after the instillation while the lens was still on the eye. The OCT configurations for imaging the tear menisci were reported previously. 3 Briefly, a real-time OCT instrument, using a light source with a center wavelength of 1310 nm and a 60 nm bandwidth, was connected to a telecentric probe. The probe was mounted with a standard slit-lamp. Parallel beam scanning enabled the capture of spatial information for the tear menisci between the lens and the eyelids. The scan width was 12 mm and speed was 8 Investigative Ophthalmology & Visual Science, March 2009, Vol. 50, No Copyright Association for Research in Vision and Ophthalmology

2 IOVS, March 2009, Vol. 50, No. 3 Tear Menisci on Contact Lenses 1107 FIGURE 1. OCT images of the cornea with a PureVision lens. OCT images showed upper (UL) and lower (LL) eyelids and a full cornea with both upper and lower tear meniscus (A G). After lens insertion (B), the soft contact lens was clearly visualized, as marked in CL (red), across entire cornea. Note that a greater lower tear meniscus was evident immediately after instillation of Bausch & Lomb rewetting drops when the lens was on the eye (F). frames per second. A video viewing system was coaxially aligned with the OCT scan. Alignment was based on observation of a specular reflex from the corneal apex. Custom software was used to process the OCT images to yield all variables. Tear meniscus parameters were obtained from processing the first good image showing both upper and lower tear menisci taken between 1 and 2 seconds after a blink. The height of the tear meniscus was calculated from the image as the transverse distance. Pink dots identifying the front surface central point of the lens and the junction points between lens and upper and lower tear menisci were marked on the image (Figs. 2A and 2B). A circle was fitted to outline the lens surface using this three-point method. Then touch points between the tear meniscus and eyelid and between the tear meniscus and lens were marked with yellow dots, and the middle FIGURE 2. Image processing to yield tear meniscus variables. Image (A) was obtained in the subject 1 to 2 seconds after lens insertion. All meniscus variables of the upper and lower tear menisci were measured using a custom software program with operator inputs. (B) Three pink dots were manually placed at the front surface central point and two junction points between the lens and upper and lower tear menisci. A circle (green) using the three-point method using the pink dots was marked to outline the lens surface. (C, D) Touch points (yellow and pink dots) between two of these elements (eye lid, lens, and tear meniscus) and a middle point (green dot) of the front edge of the tear meniscus were marked. After that, the software processed the image to yield the results.

3 1108 Wang et al. IOVS, March 2009, Vol. 50, No. 3 point of the tear meniscus front edge was marked with a green dot (Figs. 2C and 2D). After that, custom software processed the image to yield the results. The three-point method was used to fit a circle to yield the tear meniscus radius. The meniscus results included the upper tear meniscus radius (UTMR), height (UTMH), and area (UTMA), and the lower tear meniscus radius (LTMR), height (LTMH), and area (LTMA). Values were presented as means standard deviations for all 20 subjects for visits one and two. However, due to image data corruption for one eye of one subject (ID 18), only 19 subjects were analyzed for the third visit. Data analysis was performed using statistical analysis software (Statistica, StatSoft, Tulsa, OK). Repeated ANOVA (re-anova) was used to test significant differences of the measured means over time between visits, lenses, and solutions. The averaged differences of all measured variables obtained in visits one and two were also calculated. Pearson correlation was used to test correlations between variables. Repeatability of the measurements was calculated as the SD of the differences between two repeated measurements. RESULTS There were no significant differences among all measured tear menisci variables between types of lenses (re-anova, P 0.05 for all six measures over the three checkpoints; Table 1; Fig. 1) or between visits one and two (P 0.05; Table 1). The menisci immediately after lens insertion were significantly greater than those before lens wear (P 0.005; Table 1; Figs. 1 and 3). By 20 minutes after lens insertion, the values of tear menisci had recovered to the baseline values (P 0.05). The repeatability of menisci measurements at baseline, lens insertion, and 20 minutes after inserting the lens were unchanged (P 0.05 for all 6 measures over three checkpoints; Table 2; Fig. 3). Changes in UTMR, UTMA, and UTMH followed similar patterns to the changes in LTMR, LTMA, and LTMH immediately after insertion of the lenses and at 20 minutes later (Table 1). The changes of the upper and lower tear meniscus variables were highly correlated with one another immediately after lens insertion and 20 minutes later (Pearson correlation, r ranged from 0.45 to 0.94, P 0.05; Fig. 4). During the third visit, tear menisci around both upper and lower eyelids were significantly increased immediately after the instillation of the lubricant (P 0.001; Fig. 5). By 20 minutes after instillation, all the variables had returned to baseline values (P 0.05). There were no significant differences between lenses for any measured variable of the tear menisci (P 0.05). Compared with results obtained in visits one and two, no differences were found between eyes and lens care solutions with each of tested lens (P 0.05). DISCUSSION The method of imaging dynamic tear distribution on the ocular surface using real-time corneal OCT was developed and validated previously. 3,4 The repeatability of the measurements was tested at baseline and after instillation of artificial tears. 3,4 This method is a non-contact, non-invasive, real-time modality. As such, it is suitable for imaging the tears of both menisci simultaneously during contact lens wear. Compared to previously reported methods in measuring tear menisci, 5 8 it has unique advantages in studying the tear system during contact lens wear. In this study, repeated measurements were conducted and no differences for each of the measured variables were found between repeated visits. The repeatability of the measurements at all test TABLE 1. Tear Meniscus Variables Measured in 20 Subjects on Two Consecutive Days* Visit Eye Lens V1 OD PureVision V2 OD PureVision V1 OS Acuvue V2 OS Acuvue Difference between Lenses UTMR Baseline Insertion min UTMH Baseline Insertion min UTMA ( m 2 ) Baseline 19,567 6,610 19,564 8,050 18,561 6,578 20,158 7, Insertion 23,022 9,611 22,133 7,672 22,309 8,349 23,934 9, min 18,348 5,183 20,020 4,884 20,106 5,978 19,990 5, LTMR Baseline Insertion min LTMH Baseline Insertion min LTMA ( m 2 ) Baseline 20,901 10,581 22,803 12,104 19,448 7,179 21,471 12,414 1,393 Insertion 25,217 10,650 28,995 13,142 28,140 15,345 26,473 15, min 17,849 4,893 17,102 8,512 22,067 10,162 18,724 7,471 2,920 * There were no significant differences among all measured tear menisci variables between types of lenses (P 0.05 for all 6 measures over the three checkpoints) and visits (P 0.05). The menisci immediately after lens insertion were significantly greater than those before lens wear (P 0.005). By 20 minutes after lens insertion, the values of tear menisci had recovered to the baseline values (P 0.05). PureVision (balafilcon A; Bausch & Lomb, Rochester, NY). Acuvue Advance (galyfilcon A; Vistakon, Jacksonville, FL).

4 IOVS, March 2009, Vol. 50, No. 3 Tear Menisci on Contact Lenses 1109 FIGURE 3. Repeated measures of tear meniscus height. The differences between two repeated measures over three checkpoints were plotted against the mean of two measurements. The mean differences of both upper and lower tear menisci were close to zero and no significant differences were found. Note the majority of the differences are within the range between the mean 2 SD. periods was comparable to the results determined in the eyes without contact lenses. 3 This confirms the good repeatability previously reported for this real-time OCT instrument, 3,4 which is also suitable to study contact lens wearers. It is capable of detecting changes in tear meniscus variables, as shown by the measurements recorded between the initial lens insertion and 20 minutes afterward, which is a normal settlement time for adapted contact lens wearers. We tested two different types of lenses to determine whether differences in materials and/or manufacturers ex- TABLE 2. The Repeatability between Two Measurements on Consecutive Days UTMR UTMH UTMA ( m 2 ) LTMR LTMH LTMA ( m 2 ) Baseline* Difference between days ,962 SD , ,950 95% Confidence Interval ,904 1, ,356 1,431 Insertion* Difference between days ,056 SD , ,388 95% Confidence Interval ,467 1, ,585 2, min* Difference between days ,045 SD , ,655 95% Confidence Interval , ,108 * For the combined right and left eyes, there were no significant differences between day 1 and day 2 for each of these checkpoints.

5 1110 Wang et al. IOVS, March 2009, Vol. 50, No. 3 FIGURE 4. Lens-specific tear meniscus variables. Averaged data from two visits showed significant differences over time. Values of both upper and lower tear menisci at lens insertion were significantly greater than the baseline values. By 20 minutes, all values had returned to baseline (P 0.05). There were also no significant differences between lenses. Bars denote 95% confidence intervals. FIGURE 5. Tear meniscus variables after rewetting with lubricant. Significant increases of menisci variables occurred for both lenses of 19 subjects immediately after the instillation of rewetting lubricant (RW). Recovery to baseline values occurred within 20 minutes (RW 20). No significant changes were found after 4 hours of lens wear compared to baseline and 20 minutes of lens wear. Bars denote 95% confidence intervals.

6 IOVS, March 2009, Vol. 50, No. 3 Tear Menisci on Contact Lenses 1111 isted. However, there were no differences in the tear meniscus variables tested in the short term. Simultaneous measurements of both upper and lower tear menisci on contact lenses in situ have not been made previously, to the best of our knowledge. The reason might be the difficulty in imaging both eyelids at the same time with a slit-lamp or tear meniscometer. 9 Real-time imaging is necessary to capture the dynamic nature of the tear system and to define a specific time after a blink for taking the measurements. In this study, high quality images were obtained to process the dimension information at a specifically defined time, between 1 and 2 seconds, after a blink. Distorted images were often obtained during the first second after the blink. These distortions were possibly due to lens movement and lens deformation. At lens insertion, increases in the tear menisci were evident. This may be due to extra fluid brought into the eye with the lenses and/or reflex tearing on insertion of the lens. The increased tear meniscus radius after lens insertion probably is related to the increase of the pre-lens tear film, as demonstrated by Nichols and King-Smith. 10 The relationship between tear meniscus radius and pre-corneal tear film thickness was also established by mathematical calculation. 11 After the 20-minute period of adaptation, tear menisci around both eyelids recovered to the baseline levels before lens wear. This suggests that wearing contact lenses might not alter the dimensions of tear menisci after a short time of adaptation. Tear meniscus dimensions in non-contact lens wearers were studied previously using the same technique. 3 The baseline meniscus data are nearly identical with those found in the contact lens wearers of this study. This implies that the tear menisci remain unchanged when subjects wear properly fitted contact lenses, thereby confirming that the tear menisci remain unaltered during contact lens wear. Further studies with a longer term of lens wear may be needed with asymptomatic and symptomatic contact lens wearers, specifically those who have dry eye complaints. The lubricant drop clearly increases the tear menisci, as evident in the third visit. However, the menisci return to the baseline within a short period. In the present study, the increase of the tear menisci recovered within 20 minutes. It is unclear whether the pre- and post-lens tear films increased after the instillation. Further studies may be needed to investigate this aspect. Interestingly, no further decreases of the tear meniscus were found after 4 hours of lens wear compared to the baseline and 20 minutes after lens wear. This may indicate that a dynamic balance was reached after the short period of adaptation. However, what happens after a long period of lens wear during the day, such as 10 hours, remains unknown. We tested the repeatability of measurements in visits one and two, using the same lenses on the same eyes with one type of lens solution, and found no differences between eyes. In visit three, we switched lenses between eyes and used a different solution in an attempt to demonstrate differences between eyes and solutions. However, as with visits one and two, we did not find significant differences between eyes or solutions. In visit three, we also demonstrated the changes after 4 hours of lens wear and instillation of artificial drops. Since this is the first study investigating the changes of both tear menisci on contact lenses, comparisons between eyes (by switching lenses) and solutions provide some insights on further study designs. There is not much in the literature regarding the differences in tear menisci on different contact lenses or the repeatability of the methods used to detect such differences. We did not calculate the sample size in this study for detecting possible differences between lenses and solutions. The method may not be sensitive enough with the sample size used in the present study to detect a difference if one exists. On the other hand, it may not be possible to know what difference might be clinically meaningful for the tear meniscus even if a difference had been found. Further studies will address this issue by investigating the relationship between tear menisci and ocular comfort. In summary, we demonstrated for the first time that OCT is a useful tool in the measurement of tear menisci on contact lenses in situ. Differences of tear menisci were found only immediately after the insertion of two different types of lenses, and recovery to baseline occurred within 20 minutes. No differences in tear menisci were found between the tested lenses. Instillation of a lubricant increases tear menisci for only a short period. Further studies should be conducted to characterize tear dynamics after long term lens wear and the use of rewetting drops. The relationship between tear distribution and dry eye symptoms in contact lens wearers also warrants further investigation. Acknowledgments The authors thank Jayachandra R. Palakuru for assistance and Britt Bromberg of Xenofile Editing for providing editing services for this manuscript. References 1. Caffery B, Richter D, Simpson T, Fonn D, Doughty M, Gordon K. The prevalence of dry eye in contact lens wearers: part 2 of the Canadian Dry Eye Epidemiology study. Optom Vis Sci. 1996;73: Caffery BE, Richter D, Simpson T, Fonn D, Doughty M, Gordon K. CANDEES. The Canadian Dry Eye Epidemiology Study. Adv Exp Med Biol. 1998;438: Wang J, Aquavella J, Palakuru J, Chung S, Feng C. Relationships between central tear film thickness and tear menisci of the upper and lower eyelids. Invest Ophthalmol Vis Sci. 2006;47: Wang J, Aquavella J, Palakuru J, Chung S. Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears. Invest Ophthalmol Vis Sci. 2006;47: Mainstone JC, Bruce AS, Golding TR. Tear meniscus measurement in the diagnosis of dry eye. Curr Eye Res. 1996;15: Maruyama K, Yokoi N, Takamata A, Kinoshita S. Effect of environmental conditions on tear dynamics in soft contact lens wearers. Invest Ophthalmol Vis Sci. 2004;45: Oguz H, Yokoi N, Kinoshita S. The height and radius of the tear meniscus and methods for examining these parameters. Cornea. 2000;19: Yokoi N, Bron A, Tiffany J, Brown N, Hsuan J, Fowler C. Reflective meniscometry: a non-invasive method to measure tear meniscus curvature. Br J Ophthalmol. 1999;83: Yokoi N, Komuro A. Non-invasive methods of assessing the tear film. Exp Eye Res. 2004;78: Nichols JJ, King-Smith PE. The impact of hydrogel lens settling on the thickness of the tears and contact lens. Invest Ophthalmol Vis Sci. 2004;45: Wong H, Fatt I, Radke C. Deposition and thinning of the human tear film. J Colloid Interface Sci. 1996;184:44 51.

Balance in the tear system plays a significant role in maintaining. Lower Volumes of Tear Menisci in Contact Lens Wearers with Dry Eye Symptoms

Balance in the tear system plays a significant role in maintaining. Lower Volumes of Tear Menisci in Contact Lens Wearers with Dry Eye Symptoms Lower Volumes of Tear Menisci in Contact Lens Wearers with Dry Eye Symptoms Qi Chen, 1 Jianhua Wang, 2 Meixiao Shen, 1 Chunyan Cai, 1 Jianhua Li, 1 Lele Cui, 1 Jia Qu, 1 and Fan Lu 1 PURPOSE. To investigate

More information

Characterization of Soft Contact Lens Edge Fitting Using Ultra-High Resolution and Ultra-Long Scan Depth Optical Coherence Tomography

Characterization of Soft Contact Lens Edge Fitting Using Ultra-High Resolution and Ultra-Long Scan Depth Optical Coherence Tomography Cornea Characterization of Soft Contact Lens Edge Fitting Using Ultra-High Resolution and Ultra-Long Scan Depth Optical Coherence Tomography Meixiao Shen, 1 Lele Cui, 1 Colleen Riley, 2 Michael R. Wang,

More information

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens An Interesting Use of Bausch and Lomb s KeraSoft IC Lens Nate Schlotthauer, OD 2012 Michigan College of Optometry Cornea and Contact Lens Resident Introduction: The KeraSoft IC lens, introduced to the

More information

High Resolution Ocular Surface OCT to Directly Measure Tear Film Thickness in Human Eyes

High Resolution Ocular Surface OCT to Directly Measure Tear Film Thickness in Human Eyes High Resolution Ocular Surface OCT to Directly Measure Tear Film Thickness in Human Eyes Rahul Yadav, B.Tech., Kyesung Lee, Ph.D., Jannick Rolland, Ph.D., James Zavislan, Ph.D., James Aquavella, M.D. and

More information

Corneal Mapping over the Contact Lens. Challenge: Getting the Most out of Soft Contact Lens Multifocals

Corneal Mapping over the Contact Lens. Challenge: Getting the Most out of Soft Contact Lens Multifocals Contact Lens Management of the Challenging Patient Disclosures: Alcon Bausch + Lomb SpecialEyes Valley Contax Vistakon Contact Lens Challenges Matthew J. Lampa, OD, FAAO lampa@pacificu.edu Challenge: Getting

More information

This is the author s version of a work that was submitted/accepted for publication in the following source:

This is the author s version of a work that was submitted/accepted for publication in the following source: This is the author s version of a work that was submitted/accepted for publication in the following source: Osuagwu, Uchechukwu L., Ogbuehi, Kelechi C., & Almubrad, Turki M. (2015) In response: Changes

More information

History of SCL. What is with all these Soft Contacts!? Krystle Kennedy, O.D. In 1999, PureVision, the world s first silicone hydrogel is introduced

History of SCL. What is with all these Soft Contacts!? Krystle Kennedy, O.D. In 1999, PureVision, the world s first silicone hydrogel is introduced History of SCL What is with all these Soft Contacts!? Publication about SCL first appeared in 1960s, by Czech doctors. Best VA 20/40 Krystle Kennedy, O.D. In March 1971, B&L had the entire soft lens system

More information

Consulting Bausch+Lomb/Valeant, NovaBay (Avenova), Google, Allergan, Vistakon, Alcon

Consulting Bausch+Lomb/Valeant, NovaBay (Avenova), Google, Allergan, Vistakon, Alcon Contact Lenses and Dry Eye Joe Barr, OD, MS, FAAO Emeritus Professor, The Ohio State University barr.2@osu.edu Financial Disclosures Stock holder: Envision, Access Media (not a major shareholder) SMM,

More information

Multifocal Contact Lenses. Steps for Success. Disclosures. Patient Selection. Presbyopic Soft Contact Lenses: Options for Success

Multifocal Contact Lenses. Steps for Success. Disclosures. Patient Selection. Presbyopic Soft Contact Lenses: Options for Success Disclosures Outside Consultant Presbyopic Soft Contact Lenses: Options for Success Precilens Coopervision Research Funds Bausch and Lomb Brooke Messer, OD, FAAO, FSLS Cornea and Contact Lens Institute

More information

The Efficacy of Verifying the Base Curve of Hydrogel Contact Lenses

The Efficacy of Verifying the Base Curve of Hydrogel Contact Lenses 276 The Efficacy of Verifying the Base Curve of Hydrogel Contact Lenses D.F.C. Loran and C.N. French C ontact lenses can only be manufactured and prescribed as accurately as they can be checked, and frustration

More information

Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens

Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens Journal of the Korean Physical Society, Vol. 49, No. 1, July 2006, pp. 121 125 Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens

More information

The War against Corneal Warpage

The War against Corneal Warpage Page 1 of 5 I-site Amsterdam Netherlands i-site@netherlens.com Home Archive April 2010 Downloads The War against Corneal Warpage Key words: Corneal Warpage, Corneal Topography, Soft Lens Fit, (R)GP lens

More information

Need for Precision Engineering in Astigmatic Contact Lenses Matias Heinrich, Chris Wildsmith Vistakon, J&J Vision Care, Inc.

Need for Precision Engineering in Astigmatic Contact Lenses Matias Heinrich, Chris Wildsmith Vistakon, J&J Vision Care, Inc. Need for Precision Engineering in Astigmatic Contact Lenses Matias Heinrich, Chris Wildsmith Vistakon, J&J Vision Care, Inc., Jacksonville, FL The Design, Manufacture and Metrology of contact lenses is

More information

Optometry s Meeting. Tom Quinn s Disclosures. Shalu Pal s Disclosures. Multifocal Contact Lenses Made Simple 5/18/2015

Optometry s Meeting. Tom Quinn s Disclosures. Shalu Pal s Disclosures. Multifocal Contact Lenses Made Simple 5/18/2015 Optometry s Meeting Multifocal Contact Lenses Made Simple Shalu Pal, O.D., F.A.A.O. Tom Quinn, O.D., M.S., F.A.A.O. Tom Quinn s Disclosures Alcon Allergan Alden Optical Bausch + Lomb CooperVision GPLI

More information

G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP

G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP Susan J. Gromacki, OD, MS, FAAO, FSLS Daniel G. Fuller, OD, FAAO, FSLS Cornea, Contact Lenses and Refractive Technologies Section The American Academy of Optometry

More information

Fitting Manual Use with kerasofttraining.com

Fitting Manual Use with kerasofttraining.com Fitting Manual Use with Fitting Manual: Contents This fitting manual is best used in conjunction with KeraSoft IC online training. To register, please visit www. 01 Kerasoft IC Design - Outlines the KeraSoft

More information

Better Optics Deliver Clear, Consistent Vision

Better Optics Deliver Clear, Consistent Vision Better Optics Deliver Clear, Consistent Vision Learn how the PureVision2 family can satisfy patients and help build your practice. By Agustin Gonzalez, OD Learning What Patients Want The NSIGHT study provides

More information

Tangible Hydra-PEG: A Novel Custom Contact Lens Coating Technology Designed to Improve Patient Comfort and Satisfaction

Tangible Hydra-PEG: A Novel Custom Contact Lens Coating Technology Designed to Improve Patient Comfort and Satisfaction Tangible Hydra-PEG: A Novel Custom Contact Lens Coating Technology Designed to Improve Patient Comfort and Satisfaction Christine W. Sindt, OD, FAAO Director, Contact Lens Service Clinical Associate Professor

More information

Experience with correcting myopia with different types of contact lenses

Experience with correcting myopia with different types of contact lenses Experience with correcting myopia with different types of contact lenses Edward BENNETT Refer this article as: Bennett, E., Experience with correcting myopia with different types of contact lenses, Points

More information

case report Scleral lens fit based on OCT data

case report Scleral lens fit based on OCT data Page 1 of 5 I-site Amsterdam Netherlands i-site@netherlens.com Home Archive September 2009 Downloads case report Scleral lens fit based on OCT data Key words: scleral lens, ocular coherence tomography,

More information

Introducing an enlightened scleral lens designed specifically for regular corneas.

Introducing an enlightened scleral lens designed specifically for regular corneas. ZEN TM RC scleral lenses Introducing an enlightened scleral lens designed specifically for regular corneas. NEW ZEN RC ALL THE BENEFITS OF ZENLENS SCLERAL LENSES IN A SMALLER DIAMETER. The Zen RC lens

More information

Fitting Manual Use with

Fitting Manual Use with Fitting Manual Use with The KeraSoft IC Lens for and Other Irregular Corneas The KeraSoft IC is a front surface asphere or aspheric toric prism ballasted lens with balanced overall thickness and wavefront

More information

OPH 260 BASIC CONTACT LENS CONCEPTS

OPH 260 BASIC CONTACT LENS CONCEPTS OPH 260 BASIC CONTACT LENS CONCEPTS COURSE DESCRIPTION: Prerequisites: OPH 121 and OPH 141 Corequisites: None This course introduces the theory of contact lens fitting. Emphasis is on rigid and soft contact

More information

Introducing a lens that can take your scleral fitting to a higher plane.

Introducing a lens that can take your scleral fitting to a higher plane. Introducing a lens that can take your scleral fitting to a higher plane. Alden Optical s newest specialty lens has arrived: Zenlens, a mini-scleral, fully vaulting lens co-designed with Jason Jedlicka,

More information

The Impact of New Generation Aspherical Soft Contact Lenses on Quality of Vision: A Comparison with Spherical Contact Lenses and Spectacle Correction

The Impact of New Generation Aspherical Soft Contact Lenses on Quality of Vision: A Comparison with Spherical Contact Lenses and Spectacle Correction Deniz Oral, Maryo C. Kohen, Melda Yenerel, Ebru Gorgun, Sule Ziylan, Ferda Ciftci Yeditepe University Faculty of Medicine, Department of Ophthalmology, Istanbul Introduction The correction of higher order

More information

Trouble Shooting Guide for Ortho-K lenses

Trouble Shooting Guide for Ortho-K lenses Trouble Shooting Guide for Ortho-K lenses The basic design of the third generation e Lens for Orthokeratology 1. Optic Zone (Base curve, Compression zone, BC) width 5.6 to 6.4mm 2. Fitting curve (second

More information

beultra Bausch + Lomb ULTRA TM for the digital age VISION CARE

beultra Bausch + Lomb ULTRA TM for the digital age VISION CARE beultra Bausch + Lomb ULTRA TM for the digital age VISION CARE ON AVERAGE, A PERSON BLINKS 18 TIMES PER MINUTE. 1 when using digital devices, we can blink up to 66% FEWER TIMES PER MINUTE. 1 This may lead

More information

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide Irregular Cornea ROSE K2 Soft TM Practitioner s Fitting Guide ROSE K2 Soft Applications Design ROSE K2 Soft is a daily wear soft lens for irregular corneas. ROSE K2 Soft is a 3 month replacement lens when

More information

Chapter Ray and Wave Optics

Chapter Ray and Wave Optics 109 Chapter Ray and Wave Optics 1. An astronomical telescope has a large aperture to [2002] reduce spherical aberration have high resolution increase span of observation have low dispersion. 2. If two

More information

clip Calculation of the power of an iris lens for distant vision ~~~~~~~~~~~~~~~~~~~~~~t P/L2PIL FLI specification: The Netherlands

clip Calculation of the power of an iris lens for distant vision ~~~~~~~~~~~~~~~~~~~~~~t P/L2PIL FLI specification: The Netherlands Brit. _7. Ophthal. (I973) 57, 735 Calculation of the power of an iris lens for distant vision NI. C. COLENBRANDER Department of Ophthalmology, University of Levden, The Netherlands clip Until now most

More information

ADVANCED CLINICAL APPLICATIONS AND TROUBLESHOOTING IN SCLERAL LENSES

ADVANCED CLINICAL APPLICATIONS AND TROUBLESHOOTING IN SCLERAL LENSES ADVANCED CLINICAL APPLICATIONS AND TROUBLESHOOTING IN SCLERAL LENSES Langis Michaud, OD Jason Jedlicka, OD Disclosures Langis Honorarium and research grants Alcon Cooper Allergan Bausch*Lomb Johnson *

More information

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design Contents Basics of asphericity Visual quality and aspheric IOL Features of HOYA ABC Design 2 What is asphericity? Deviating from the spherical

More information

White Paper. Importance of Rotational Stability and Tear Film Stability in Toric Contact Lens Wearers

White Paper. Importance of Rotational Stability and Tear Film Stability in Toric Contact Lens Wearers White Paper Importance of Rotational Stability and Tear Film Stability in Toric Contact Lens Wearers Jessica Mathew, OD, PhD, FAAO Alcon Medical Affairs, North America Introduction Astigmatism occurs when

More information

Effects of Pupil Center Shift on Ocular Aberrations

Effects of Pupil Center Shift on Ocular Aberrations Visual Psychophysics and Physiological Optics Effects of Pupil Center Shift on Ocular Aberrations David A. Atchison and Ankit Mathur School of Optometry & Vision Science and Institute of Health & Biomedical

More information

introducing The Only Naturally Wettable Two-Week Silicone Hydrogel

introducing The Only Naturally Wettable Two-Week Silicone Hydrogel introducing The Only Naturally Wettable Two-Week Silicone Hydrogel Avaira: Experience Wettability That s More Than Surface Deep Thanks to CooperVision s unique Aquaform technology, new Avaira two-week

More information

HARD TORIC CONTACT LENSES ASTIGMATISM DEFINITION AND OPTIC BASIS

HARD TORIC CONTACT LENSES ASTIGMATISM DEFINITION AND OPTIC BASIS Mario Giovanzana Milano 20.06.01 HARD TORIC CONTACT LENSES ASTIGMATISM DEFINITION AND OPTIC BASIS An astigmatism, according to Whevell (1817) has been defined as astigmatism or astigmatic ametropia; the

More information

OCULUS Keratograph 4. Topographer. We focus on progress

OCULUS Keratograph 4. Topographer. We focus on progress OCULUS Keratograph 4 Topographer We focus on progress Ophthalmologist Versatile and precise For me the Keratograph 4 is an indispensable device for diagnosis and surgical planning. Its automatic measurement

More information

Novel 3D Computerized Threshold Amsler Grid Test CA, USA

Novel 3D Computerized Threshold Amsler Grid Test CA, USA Novel 3D Computerized Threshold Amsler Grid Test Wolfgang Fink 1,2 and Alfredo A. Sadun 2 1 California Institute of Technology, Pasadena, CA, USA 2 Doheny Eye Institute, Keck School of Medicine, University

More information

Vertical and Horizontal Corneal Epithelial Thickness Profile Using Ultra-High Resolution and Long Scan Depth Optical Coherence Tomography

Vertical and Horizontal Corneal Epithelial Thickness Profile Using Ultra-High Resolution and Long Scan Depth Optical Coherence Tomography Vertical and Horizontal Corneal Epithelial Thickness Profile Using Ultra-High Resolution and Long Scan Depth Optical Coherence Tomography Shuangqing Wu 1,2., Aizhu Tao 2,3., Hong Jiang 2, Zhe Xu 2,3, Victor

More information

Simple method of determining the axial length of the eye

Simple method of determining the axial length of the eye Brit. Y. Ophthal. (1976) 6o, 266 Simple method of determining the axial length of the eye E. S. PERKINS, B. HAMMOND, AND A. B. MILLIKEN From the Department of Experimental Ophthalmology, Institute of Ophthalmology,

More information

Why choose Contact Lenses?

Why choose Contact Lenses? Why choose Contact Lenses? Flexible packages, whatever your lifestyle. We can fit lenses to correct 99% of prescriptions! Ask about our free trial today. Anyday/Everyday. WHY CHOOSE DUNCAN AND TODD? Because

More information

Why choose Contact Lenses?

Why choose Contact Lenses? Why choose Contact Lenses? Flexible packages, whatever your lifestyle. We can fit lenses to correct 99% of prescriptions! invernessopticians.co.uk Ask about our free trial today. Anyday/Everyday. She wears

More information

This is the author s version of a work that was submitted/accepted for publication in the following source:

This is the author s version of a work that was submitted/accepted for publication in the following source: This is the author s version of a work that was submitted/accepted for publication in the following source: Atchison, David A. & Mathur, Ankit (2014) Effects of pupil center shift on ocular aberrations.

More information

Automated Spectrophotometric Spatial Profiling of Coated Optical Wafers

Automated Spectrophotometric Spatial Profiling of Coated Optical Wafers Automated Spectrophotometric Spatial Profiling of Coated Optical Wafers Application note Materials testing and research Authors Travis Burt Fabian Zieschang Agilent Technologies, Inc. Parts of this work

More information

Disclosures. Unique to Ubiquitous. Evolution of Contact Lenses. Lecture Objectives. Evolution of Contact Lenses. Disposable Contact Lenses

Disclosures. Unique to Ubiquitous. Evolution of Contact Lenses. Lecture Objectives. Evolution of Contact Lenses. Disposable Contact Lenses Disclosures Practicing Full Scope Primary Care Optometry: New Innovations in Daily Disposable Contact Lenses Pamela A. Lowe, O.D., F.A.A.O Diplomate, American Board of Optometry Professional Eye Care Center,

More information

ClearKone Restoring vision. Changing lives.

ClearKone Restoring vision. Changing lives. ClearKone Restoring vision. Changing lives. For additional information on fitting ClearKone, please visit www.fitsynergeyes.com to view fitting videos, case studies, NaFL pictures and more. FITTING GUIDE

More information

Optometrist Private ophthalmologists

Optometrist Private ophthalmologists Public hospital Post-operative follow up Specialist diagnosis Screening service Optometrist Private ophthalmologists Ophthalmic diagnostics anywhere, anytime TEARSCOPE (Tear Film Screening) The scattered

More information

Melissa Barnett, OD, FAAO, FSLS, FBCLA

Melissa Barnett, OD, FAAO, FSLS, FBCLA ??????? Melissa Barnett, OD, FAAO, FSLS, FBCLA?? Melissa Barnett has received honoraria from: Acculens Alcon Allergan Bausch + Lomb Coopervision JJVC Vistakon Novabay Gas Permeable Lens Institute (GPLI)

More information

This is the author s version of a work that was submitted/accepted for publication in the following source:

This is the author s version of a work that was submitted/accepted for publication in the following source: This is the author s version of a work that was submitted/accepted for publication in the following source: Osuagwu, Uchechukwu L. & Ogbuehi, Kelechi (2016) In response: UV vis light transmittance through

More information

Respecting and Stabilizing the Tear Film

Respecting and Stabilizing the Tear Film AUGUST 2013 Respecting and Stabilizing the Tear Film Panelists discuss a daily disposable lens designed to work with the tear film to provide moisture with every blink. Sponsored by M O D E R A T O R P

More information

Submission to the American Optometric Association Contact Lens and. Cornea Section, Student Research Awards Committee. for

Submission to the American Optometric Association Contact Lens and. Cornea Section, Student Research Awards Committee. for Submission to the American Optometric Association Contact Lens and Cornea Section, Student Research Awards Committee for My Most Challenging Contact Lens Case By: Melisa Hockett Third year Doctor of Optometry

More information

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST PART 3: LENS FORM AND ANALYSIS PRACTICE TEST 1. 2. To determine the power of a thin lens in air, it is necessary to consider: a. front curve and index of refraction b. back curve and index of refraction

More information

This experiment is under development and thus we appreciate any and all comments as we design an interesting and achievable set of goals.

This experiment is under development and thus we appreciate any and all comments as we design an interesting and achievable set of goals. Experiment 7 Geometrical Optics You will be introduced to ray optics and image formation in this experiment. We will use the optical rail, lenses, and the camera body to quantify image formation and magnification;

More information

SOFT (HYDROPHILIC) CONTACT LENSES DAILY WEAR FOR PLANNED REPLACEMENT OR DAILY DISPOSABLE. PRACTITIONER FITTING GUIDE July 2009

SOFT (HYDROPHILIC) CONTACT LENSES DAILY WEAR FOR PLANNED REPLACEMENT OR DAILY DISPOSABLE. PRACTITIONER FITTING GUIDE July 2009 BIOMEDICS 55 (ocufilcon D) BIOMEDICS 55 Toric (ocufilcon D) BIOMEDICS 55 Multifocal (ocufilcon D) SOFT (HYDROPHILIC) CONTACT LENSES DAILY WEAR FOR PLANNED REPLACEMENT OR DAILY DISPOSABLE PRACTITIONER FITTING

More information

Siesta 100. Training + Certification Guide. Bringing eye care professionals the finest quality, custom GP lens designs.

Siesta 100. Training + Certification Guide. Bringing eye care professionals the finest quality, custom GP lens designs. o r t h o k er a t o l o g y Training + Certification Guide Bringing eye care professionals the finest quality, custom GP lens designs. 800-792-1095 tfoptics.com Training and Certification Corneal Shape

More information

This is the author s version of a work that was submitted/accepted for publication in the following source:

This is the author s version of a work that was submitted/accepted for publication in the following source: This is the author s version of a work that was submitted/accepted for publication in the following source: Tyagi, Garima, Collins, Michael J., Read, Scott A., & Davis, Brett A. (2012) Corneal changes

More information

Slide 1. Slide 2. Slide 3. Richard Dorer NCLE

Slide 1. Slide 2. Slide 3. Richard Dorer NCLE Slide 1 Heart of America 2014 Richard Dorer NCLE richarddorer@gmail.com Slide 2 I am a paid representative and consultant of Blanchard Contact Lens. I represent Blanchard Contact Lens in the Mid-Western

More information

4th International Congress of Wavefront Sensing and Aberration-free Refractive Correction ADAPTIVE OPTICS FOR VISION: THE EYE S ADAPTATION TO ITS

4th International Congress of Wavefront Sensing and Aberration-free Refractive Correction ADAPTIVE OPTICS FOR VISION: THE EYE S ADAPTATION TO ITS 4th International Congress of Wavefront Sensing and Aberration-free Refractive Correction (Supplement to the Journal of Refractive Surgery; June 2003) ADAPTIVE OPTICS FOR VISION: THE EYE S ADAPTATION TO

More information

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer Wave Front Topography ReSeeVit Evolution Topography Module for Modi Topographer Introduction The aberrations in the central optical zone have a greater effect than those closer to the edge. From an optical

More information

Correcting Astigmatism with Contact Lenses John M. Laurent, OD, PhD William J. Benjamin, OD, PhD

Correcting Astigmatism with Contact Lenses John M. Laurent, OD, PhD William J. Benjamin, OD, PhD Correcting Astigmatism with Contact Lenses John M. Laurent, OD, PhD William J. Benjamin, OD, PhD Photo: Annie Chang, OD, and Dawn Lam, OD. Before we start... Accurate refraction critical in most cases

More information

Paragon CRT Dual Axis Quick Reference Guide

Paragon CRT Dual Axis Quick Reference Guide Paragon CRT Dual Axis Quick Reference Guide DUAL CRT AXIS PARAGON CRT DUAL AXIS OPTIONS TO COMPENSATE FOR PERIPHERAL CORNEAL ELEVATION DIFFERENCES Most eyes with corneal astigmatism manifest a significant

More information

An assessment of regional differences in corneal thickness in normal human eyes, using the Orbscan II or ultrasound pachymetry

An assessment of regional differences in corneal thickness in normal human eyes, using the Orbscan II or ultrasound pachymetry Optometry (2007) 78, 181-190 An assessment of regional differences in corneal thickness in normal human eyes, using the Orbscan II or ultrasound pachymetry Michael J. Doughty, Ph.D., and Sven Jonuscheit,

More information

The New Corvis ST. Evaluation of corneal biomechanical response, tonometry and pachymetry. Biomechanical Response

The New Corvis ST. Evaluation of corneal biomechanical response, tonometry and pachymetry. Biomechanical Response The New Corvis ST Evaluation of corneal biomechanical response, tonometry and pachymetry. The revolutionary Corvis ST records the reaction of the cornea to a defined air pulse using a newly developed high-speed

More information

Sets distance refraction. Moves camera forward / backward. Moves camera up / down. Moves camera left / right. Starts image acquisition (HRT 3 only)

Sets distance refraction. Moves camera forward / backward. Moves camera up / down. Moves camera left / right. Starts image acquisition (HRT 3 only) The perfect Image General workflow Do not conduct any examination beforehand that can disturb the tear film (e.g., examination using a contact glass, applanation tonometry). Explain the examination process

More information

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Seema Somani PhD, Ashley Tuan OD, PhD, and Dimitri Chernyak PhD VISX Incorporated, 3400 Central Express Way, Santa Clara, CA

More information

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina What s Fundus photography s purpose? To document the retina Photographers role to show the retina Document other ocular structures Why do we take them? Why do we do it? We as photographers help the MD

More information

Devices & Services Company

Devices & Services Company Devices & Services Company 10290 Monroe Drive, Suite 202 - Dallas, Texas 75229 USA - Tel. 214-902-8337 - Fax 214-902-8303 Web: www.devicesandservices.com Email: sales@devicesandservices.com D&S Technical

More information

Crizal UV: the new anti-reflection lens that protects against UV radiation

Crizal UV: the new anti-reflection lens that protects against UV radiation Crizal UV: the new anti-reflection lens that protects against UV radiation Pascale LACAN e- Dr. Tito DE AYGUAVIVES e- mail, mail Publication date : 10/2012, Luc BOUVIER e-mail Refer this article as: Lacan,

More information

Small lens. Great freedom.

Small lens. Great freedom. thezeisslens.com Contact Day 1, the comfortable daily lens. For active moments without glasses. Small lens. Great freedom. thezeisslens.com I like to be active and on the move during my free time. I will

More information

End-of-Chapter Exercises

End-of-Chapter Exercises End-of-Chapter Exercises Exercises 1 12 are conceptual questions designed to see whether you understand the main concepts in the chapter. 1. Red laser light shines on a double slit, creating a pattern

More information

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST - KEY

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST - KEY PART 3: LENS FORM AND ANALYSIS PRACTICE TEST - KEY d 1. c 2. To determine the power of a thin lens in air, it is necessary to consider: a. front curve and index of refraction b. back curve and index of

More information

THE EFFECT OF MODIFIED SPECTACLES ON THE FIELD OF VIEW OF THE HELMET DISPLAY UNIT OF THE INTEGRATED HELMET AND DISPLAY SIGHTING SYSTEM

THE EFFECT OF MODIFIED SPECTACLES ON THE FIELD OF VIEW OF THE HELMET DISPLAY UNIT OF THE INTEGRATED HELMET AND DISPLAY SIGHTING SYSTEM USAARL REPORT NO. 84-12 THE EFFECT OF MODIFIED SPECTACLES ON THE FIELD OF VIEW OF THE HELMET DISPLAY UNIT OF THE INTEGRATED HELMET AND DISPLAY SIGHTING SYSTEM By William E. McLean Clarence E. Rash SENSORY

More information

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12 Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works How the Eye Works 3 How the eye works Light rays

More information

The Unique Mu l t i f o c a l S i l i c o n e H y d r o g e l

The Unique Mu l t i f o c a l S i l i c o n e H y d r o g e l C2 MULTIFOCAL The Unique Mu l t i f o c a l S i l i c o n e H y d r o g e l C o n t a c t L e n s UNIQUE DESIGN E X C E L L E N T V I S I O N F O R A L L P R E S B Y O P E S VISUAL EXCELLENCE IN SIMULTANEOUS

More information

A Study of the Effectiveness of CK One-Step Lenses for Correcting Myopia

A Study of the Effectiveness of CK One-Step Lenses for Correcting Myopia 13 A Study of the Effectiveness of CK One-Step Lenses for Correcting Myopia Ann M. Foss Faculty Sponsor: Margaret A. Maher, Departments of Biology/Microbiology Clinical Sponsor: Richard L. Foss, O.D. ABSTRACT

More information

MEASUREMENTS OF THE SAGITTAL AXIS OF THE HUMAN

MEASUREMENTS OF THE SAGITTAL AXIS OF THE HUMAN Brit. J. Ophthal. (1968) 52, 81 MEASUREMENTS OF THE SAGITTAL AXIS OF THE HUMAN EYE IN VIVO DURING APPLANATION OF THE CORNEA*t$ BY From the Second Eye Clinic, University of Vienna, Austria (Director: Univ.

More information

FITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near

FITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near FITTING GUIDE Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near P R O G R E S S I V E The unique advanced-technology Duette hybrid contact lenses are

More information

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology Acufocus Financial Disclosure I have no financial interest in any subject presented Presbyopia Correction: The Holy Grail of Ophthalmology Presbyopia Surgery Inlay Concept First conceived in 1949 by Dr.

More information

Chapter 23 Study Questions Name: Class:

Chapter 23 Study Questions Name: Class: Chapter 23 Study Questions Name: Class: Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When you look at yourself in a plane mirror, you

More information

The pupil of the eye is a critical limiting factor in the optics

The pupil of the eye is a critical limiting factor in the optics Pupil Location under Mesopic, Photopic, and Pharmacologically Dilated Conditions Yabo Yang, 1,2 Keith Thompson, 3 and Stephen A. Burns 1 PURPOSE. To determine whether there are systematic changes in pupil

More information

Bringing you value and support

Bringing you value and support Bringing you value and support Bausch + Lomb, Boston Materials Adding Value. Expand the custom contact lens business through product, services, technology GP materials Soft lens materials Licensing of

More information

Technicians & Nurses Program

Technicians & Nurses Program ASCRS ASOA Symposium & Congress Technicians & Nurses Program April 17-21, 2015 San Diego, California What Do All These Colors Mean And who s paying for all the ink? BLUF: Red is bad. Frank W. Scribbick,

More information

family of lens designs fitting guide ICD is Exclusively Manufactured In

family of lens designs fitting guide ICD is Exclusively Manufactured In TM family of lens designs fitting guide ICD is Exclusively Manufactured In paragon 1 Select Initial Diagnostic Lens: Identify the Corneal Condition Normal Depth Eyes Normal Shapes Median Flat KReading

More information

Macula centred, giving coverage of the temporal retinal. Disc centred. Giving coverage of the nasal retina.

Macula centred, giving coverage of the temporal retinal. Disc centred. Giving coverage of the nasal retina. 3. Field positions, clarity and overall quality For retinopathy screening purposes in England two images are taken of each eye. These have overlapping fields of view and between them cover the main area

More information

What is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World?

What is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World? Ian Cox, BOptom, PhD, FAAO Distinguished Research Fellow Bausch & Lomb, Rochester, NY Acknowledgements Center for Visual

More information

Lecture 2 Slit lamp Biomicroscope

Lecture 2 Slit lamp Biomicroscope Lecture 2 Slit lamp Biomicroscope 1 Slit lamp is an instrument which allows magnified inspection of interior aspect of patient s eyes Features Illumination system Magnification via binocular microscope

More information

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT Keratoconus Nipple Cone Irregular Cornea Post Graft PRACTITIONER S FITTING GUIDE NIPPLE CONE IRREGULAR CORNEA POST GRAFT Four lens designs... One simple systematic approach to fitting Featuring Easy-to-fit

More information

Table of contents. 5 Swiss precision for clear vision. 6 What types of defective eyesight are there? 8 What is refractive eye surgery?

Table of contents. 5 Swiss precision for clear vision. 6 What types of defective eyesight are there? 8 What is refractive eye surgery? www.laservista.ch Table of contents 5 Swiss precision for clear vision 6 What types of defective eyesight are there? 8 What is refractive eye surgery? 9 Which procedure is an option for me? 10 Laser procedures

More information

Mehrstärken- Kontaktlinsen Michael Wyss

Mehrstärken- Kontaktlinsen Michael Wyss Mehrstärken- Kontaktlinsen Michael Wyss dipl. Augenoptiker FAAO mwyss@kontaktlinsenstudio.ch kontaktlinsenstudio baertschi, Bern, Switzerland Situation on the market Blind-Date Get in contact with your

More information

Chapter 3. Introduction to Zemax. 3.1 Introduction. 3.2 Zemax

Chapter 3. Introduction to Zemax. 3.1 Introduction. 3.2 Zemax Chapter 3 Introduction to Zemax 3.1 Introduction Ray tracing is practical only for paraxial analysis. Computing aberrations and diffraction effects are time consuming. Optical Designers need some popular

More information

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs Soft CL Multifocals Design and Fitting Mark Andre, FAAO Associate Professor of Optometry Pacific University Mark Andre, FAAO is affiliated with CooperVision, as a consultant. Issues Surrounding Multifocals

More information

Kodak (ASA 400). image by computer. A given point (xi, yi) was. xi is the distance from the axis in the optical image,

Kodak (ASA 400). image by computer. A given point (xi, yi) was. xi is the distance from the axis in the optical image, British Journal of Ophthalmology, 1986, 70, 668-672 Measurement method of the anterior chamber volume by image analysis TAKEHISA KONDO,' MASAO MIURA,' AND MASATSUGU IMAMICHIP From the 'Department of Ophthalmology,

More information

PREMIUM LENSES WITH VARIABLE BASE CURVE

PREMIUM LENSES WITH VARIABLE BASE CURVE PREMIUM LENSES WITH VARIABLE BASE CURVE Inspired by nature - 1 - CONTENT THE ADVANCEMENT OF CAMBER CAMBER TECHNOLOGY Features and Properties Camber Benefits EXPLORING CAMBER LENS SERIES NATURAL NATURAL

More information

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)? Wavefront-Guided Optics in Clinic: Financial Disclosures The New Frontier November 4, 2017 Matthew J. Kauffman, OD, FAAO, FSLS STAPLE Program Soft Toric and Presbyopic Lens Education Gas Permeable Lens

More information

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12 Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works Light rays enter the eye through the clear cornea,

More information

A New Way to See THE WORLD

A New Way to See THE WORLD Contact Lens SPECTRUM MARCH 2013 A New Way to See THE WORLD Learn how a new daily disposable lens mimics the natural properties of the eye, providing comfortable vision throughout the day. Sponsored by

More information

OCULUS Keratograph 5M Topographer

OCULUS Keratograph 5M Topographer OCULUS Keratograph 5M Topographer OCULUS Keratograph 5M Topographer The multi-purpose topographer has become an integral part of the ophthalmology and optometry practices. User independent measurements

More information

OPTOMETRY ORIGINAL PAPER. Dynamic wavefront aberrations and visual acuity in normal and dry eyes

OPTOMETRY ORIGINAL PAPER. Dynamic wavefront aberrations and visual acuity in normal and dry eyes C L I N I C L N D E X P E R I M E N T L OPTOMETRY ORIGINL PPER Dynamic wavefront aberrations and visual acuity in normal and dry eyes Clin Exp Optom 2009; 92: 3: 267 273 Yan Wang* MD Jianjiang Xu* MD Xinghuai

More information

What you should know about LASIK and Femto-LASIK Understanding Laser Vision Correction. Patient information

What you should know about LASIK and Femto-LASIK Understanding Laser Vision Correction. Patient information What you should know about LASIK and Femto-LASIK Understanding Laser Vision Correction Patient information The strong desire to see clearly Laser Vision Correction with a proven procedure Sharp vision

More information

Refined Slanted-Edge Measurement for Practical Camera and Scanner Testing

Refined Slanted-Edge Measurement for Practical Camera and Scanner Testing Refined Slanted-Edge Measurement for Practical Camera and Scanner Testing Peter D. Burns and Don Williams Eastman Kodak Company Rochester, NY USA Abstract It has been almost five years since the ISO adopted

More information