1 SWIM - Sustainable Water Integrated Management Demonstration Project Key points of using Canopy Sensors Greenseeker 505 Handheld (NTech Industries, Inc.) NDVI SPAD-502Plus (Konica Minolta) Chlorophyll content Infrared Thermometer INF151 (UEI) Canopy temperature Visual Senescence Scoring Stay-green 1

2 (Zadoks scale) Chlorophyll Content F v /F m Canopy Temperature NDVI Senescence Greenseeker 505 HandHeld 1. When to measure? 2. Equipment a) Mechanical Specifications b) Components & Accessories 3. Measurements a) Preparation b) Trial Measurements 4. Data Download & Processing 5. Common Problems & Solutions 2

3 GreenSeeker - NDVI Any time of the day. Plant surfaces must be dry and not wet from dew. Avoid windy days. Wind can modify canopy structure. Early vigor: 5, 10 and 15 days after emergence. Biotic and abiotic stress detection: measurements before, during and after stress. Biomass and crop growth rate: periodic measurements from emergence to end of anthesis. Senescence: weekly or every 3 to 4 days measurements from anthesis to maturity. a) Mechanical Specifications - Weight Unit 6 kg. - Weight of Unit, case and accessories 17 kg. - Case dimensions 35.5 x 35.5 x cm. - Over long distances should be transported in its box b) Components & Accessories - GreenSeeker V AC battery charger Charging Keeping the unit plugged when not in use will extend Charged the battery life. - Control Box Battery, circuit board to interface power and switches to the sensor and external connectors. Power Switch/ Indicator External Data port (RS232 Collection of data) Power connector 3

4 b) Components & Accessories Pocket PC displays and stores the data from the sensor. Should always be charged if not the collected data will be erased. NTech Capture pre-loaded software to capture the readings from GreenSeeker Handheld Sensor, display the current reading, and store for later data analysis or to make fertilizer recommendations. Pocket PC Pocket PC Cradle Trigger Switch (small buzzer) Extension pole DB9 (RS232) serial cable b) Components & Accessories - Sensor head Takes the reflectance readings Active - Internal illumination Shoulder Strap Sensor Head Sensor mount Pocket PC Extension pole Control box Pask A, Pietragalla J, Mullan D, Reynolds M (2012) Physiological breeding II: A field guide to wheat phenotyping. CIMMYT, Mexico 12 pin connector 4

5 a) Preparation 1. Fully charge batteries of Pocket PC & Sensor Unit - Usually > 6h (over-night). 2. Check connections - Sensor head, control box, extension pole and Pocket PC. 3. Check sensor head position to the crop - Horizontally positioned in relation to the ground - Adjust the distance to the canopy (string with a weight helps), by adjusting the sensor head angle and the extension pole. 4. Adjust shoulder straps - Place the strap diagonally across the body. b) Trial measurements 1. Turn on the Control Box and the Pocket PC. Allow 10 min to equilibrate with ambient temperature. If Unidentified USB Device error message appears on the Pocket PC display write: ftdi_ser.dll and press OK. 2. On the Pocket PC: 2.1. Go to Start > Programs and run NTechCapture software; 2.2. Select Sensor > Start GreenSeeker and select Logging Plots. 3. Position the Sensor at the start of the plot. Press and hold the trigger and traverse the region (speed 1 m s -1 ). Release the trigger. Data is recorded to the file. 4. When completed the data collection, go to File > Save assign file name. Display NDVI: last NDVI point recorded for the plot AVG NDVI: average NDVI of all points measured for the plot Sample: number of measured plots 5

6 Problem: Unidentified USB Device error message appears on the Pocket PC display after turning it on: Solution: write ftdi_ser.dll : 6

7 When data is saved three comma-delimited ASCII text files are created in the Pocket PC internal memory or removable memory card in My Device\My Documents\NtechCapture: - filename.txt all data collected. NDVI, Vegetation Index (VI = Red/NIR) values for each plot ( 10 values/ sec); - filenameavg.txt average NDVI and VI for each plot; - filenamediag.txt diagnostic information for the sensor. Note: Once the software is closed you cannot open a created file. After saving a data file, a new file can be created by tapping File > New. This will clear the data cells and allow the collection of new readings. Download files to the computer: Connect PDF to the USB-port and copy files from My Computer/ Mobile device to the computer (ActiveSync must be installed in the computer). Open files in MS Excel: 1. Launch Excel and select Open from the File menu. 2. Change File Types to All Files and select the.txt data file. 3. Select Delimited Text, delimited by commas and spaces. This will import data into separate columns in the spreadsheet file. 7

8 Problem Unidentified USB Device error message appears on the Pocket PC display after turning it on. Large variance in data. Variable reflectance values and/or with high error variance. Unintentional value recorded. Solution Write: ftdi_ser.dll and press OK. GreenSeeker sensor not held centrally over plot and/ or small plots large border effect. Low battery causing decreasing light source intensity affecting reflectance value. Charge unit. Take note of plot number and delete value during processing. GreenSeeker does not log data. Pocket PC errors or hangs. Not all counts are recorded. Battery does not charge. Check connections and cable between Pocket PC and Control Box. If connections and cable are fine, reset Pocket PC (press & hold power button select reset). (e.g. gate not available ). Reset Pocket PC. General file without all counts. Usually a problem with the cable. Battery charger light does not come on. Unit battery not charging. Probably broken fuse. Open Control Box and replace fuse. SPAD-502Plus 1. When to measure? 2. Equipment 3. Measurements a) Preparation b) Trial Measurements 4. Common Problems & Solutions 5. Maintenance (Reading Checker) 8

9 SPAD Chlorophyll Content No restrictions on time of the day and environmental conditions. Leaf surface should be dry. Biotic and abiotic stress detection: measurements before, during and after stress. Peak chlorophyll: measurements should be done early in the season, heading and mid-grain filling. Senescence: weekly or every 3 to 4 days measurements from anthesis to maturity. SPAD-502Plus (Konica Minolta) Chlorophyll meter Measuring Head Measurement Centre Line Receptor Window Sliding Depth Stop Display Average Button Finger rest Power Switch Data Recall Button All Data Clear Button 1 Data Delete Button Battery Chamber Cover (2 AA batteries) 9

10 a) Preparation 1. Measuring chamber should be clean and the rubber seal intact. 2. Turn SPAD on and allow 10 min to equilibrate with the ambient temperature. b) Trial Measurements 1. Calibration (always after turning on) - With no sample close measuring head until beep. - SPAD is calibrated. Battery indicator b) Trial Measurements 2. Calibration Errors - Series of beeps measuring head was not completed closed during calibration or was opened before calibration was finished. Repeat calibration keeping measuring head completely closed until calibration is finished. - Series of beeps measuring head emitting and/ or receiving windows may be dirty. Clean and repeat calibration. 10

11 b) Trial Measurements 3. Measurement 3.1. Adjust siding Depth Stop Place the leaf in the sensor: - Measuring area 2 mm x 3 mm up to 1.2 mm thick; - 1/3 to 1/2 of the way to the leaf base; - Adaxial surface facing upwards; - Avoid midrib, major veins & thick parts of the leaf Close measuring head until beep Reading displays in the screen. b) Trial Measurements 3. Measurement 3.5. Repeat 3.1. to 3.4 up to N=5 (SPAD can store up to 4096 values or 1488 with GPS) Review readings (and graphic trend): - Press Data Recall button; - Remove outliers and retake measurements if needed Press Average button and record average value Press All Data Clear button twice (go to next plot start from 1.). 3. Measurement Errors Series of beeps and ERROR message while measuring: - Measured head was not closed completely or was opened before the measurement was completed. - Sample is too thick or thin. - Repeat measurement with head completely closed. 11

12 Problem Solution SPAD not giving readings but emitting beeps when closed. Large variation in SPAD values within a plot. Damage to the surface of the crop (e.g. frost, disease, etc.). Chamber and/ or chamber seal is dirty or leaf not positioned correctly. Retake reading. Maintain consistent point of measurement along the leaf. Lower values might be associated with the leaf being: damaged, diseased or leaf tip has been inserted. Healthy and clean leaves should be used. Do not use SPAD in dead material and avoid damaged areas of the crop. 1. Turn ON while pressing 1 DATA DELETE and DATA RECAL. 2. Calibrate 5. Check Average Average value should be within the range of the Reading Checker. If not clean emitting and receiving windows and repeat. If it is still not within the range, there is a possible malfunctioning contact service centre. Turn Off and On to resume normal operation. 4. Insert Reading Checker & Measure up to N=5 3. Remove Depth Stop 12

13 Infrared Thermometer INF151 (UEI) 1. When to measure? 2. Equipment 3. Measurements a) Preparation b) Trial Measurements 4. Common Problems & Solutions IRT Canopy Temperature Clear sky with little or no wind - measurements should be taken between 11:00am to 2:00pm. Days with high temperatures (> 25 C) and VPD work preferably. Leaf surface should be dry. Biotic and abiotic stress detection: measurements before, during and after stress. Senescence: weekly or every 3 to 4 days measurements from anthesis to maturity. 13

14 Infrared Thermometer INF151 (UEI) Canopy temperature IR Sensor Laser Pointer Bean Trigger (ON/ Measurement Button) Handle Battery (9V) compartment LCD Display Units Button ( F and C) Emissivity Button (0.95, 0.90, 0.85) Back Light Button (ON/ OFF) Laser Button (ON/ OFF) Infrared Thermometer INF151 (UEI) Canopy temperature Wrong Right Distance to scanned area ratio 8:1 14

15 Pen Type Hygrometer DTH10 (UEI) Temperature and Humidity meter Hold Button ON/ OFF Button MIN/ MAX Button Sensor Temp (F/C) (Change unit from F to C) Reset Button (CR2032 battery) a) Preparation 1. Turn on the temperature/ humidity meter. Allow the instrument to equilibrate with the ambient temperature (± 3 min), not exposing directly to sun. Record air temperature and relative humidity (RH). 2. Turn on infrared thermometer by pressing the trigger and check if emissivity is set to If not press Emissivity Button while pressing the trigger until 0.95 emissivity is chosen. Allow IRT to equilibrate with the ambient temperature for 10 min. b) Trial Measurements 1. Point the IRT to the plot and press the trigger - record reading (releasing the trigger activates the 7 second auto-hold). A minimum of 3 measurements per 6 m 2 plots is advised, for 1 m 2 plots one measurement is sufficient. Record the ambient temperature and RH at the start of each plot measurement. 2. Advises: - Take measurements of the part of the plot most exposed to the Sun; - Avoid the shadow of the operator; - The thermometer distance and angle should be constant; - If readings of the same plot differ > 1 C, repeat measurements. 15

16 a) Trial Measurements 3. Angle and position of the thermometer determines the Spot. Pask A, Pietragalla J, Mullan D, Reynolds M (2012) Physiological breeding II: A field guide to wheat phenotyping. CIMMYT, Mexico Problem Initial canopy temperature values higher/ lower than on the rest of the trial. Readings in the same plot differ by > 1 C. Solution IRT did not sufficient equilibrate with ambient temperature. Let IRT to equilibrate for at least 10 min with the ambient temperature. Check that IRT is being held correctly and consistently throughout measurements. Avoid borders, damaged/ senesced leaves, soil, etc.. 16

17 1. Methods/ Equipment 2. Calculations Visual Senescence Scoring Methods/ Equipment: To be performed on flag-leaves and repeated weekly or 3 to 4 days from anthesis to physiological maturity. 1. Make a general observation by standing at 45 angle to plot. 2. Randomly select and mark 5 (or more) shoots and attribute scores to each individual flag-leaf. Visual Senescence Scoring Stay-green 17

18 Fitting the senescence data score = p0 + p1 x (1 exp(( -p2 x STA/ p1)) + (10 p1 p0/ (1 + exp(-4 x p3 (STA p4)/ (10 p1 p0))) Score: visual senescence score STA: thermal time after anthesis ( C days) p0: score at anthesis p1: score at the end of the slow phase p2: maximum rate of the slow phase p3: maximum rate at rapid phase (Sen Rate ) p4: date at which p3 is reached Sen Onset : onset of senescing phase date. Stay-green associated with Sen Onset and Sen Rate

GreenSeeker Handheld Crop Sensor Features

GreenSeeker Handheld Crop Sensor Features GreenSeeker Handheld Crop Sensor Features Active light source optical sensor Used to measure plant biomass/plant health Displays NDVI (Normalized Difference Vegetation Index) reading. Pull the trigger

More information

User Guide. Heavy Duty Psychrometer + IR Thermometer. Model HD550

User Guide. Heavy Duty Psychrometer + IR Thermometer. Model HD550 User Guide Heavy Duty Psychrometer + IR Thermometer Model HD550 Introduction Congratulations on your purchase of the Extech HD550 Psychrometer. This handheld meter measures and displays Air Temperature,

More information

INTRODUCTION CHAPTER 1

INTRODUCTION CHAPTER 1 TABLE OF CONTENTS Introduction... 3 Package Contents... 5 Design... 7 Key Functions... 9 Grain Species and Measuring Ranges....11 First Steps...13 Measurement...15 Modification...19 Setup...21 Replacing

More information

Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight Ratio, Data Logging, USB Output, Single Type K Input, and Temperature Alarm

Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight Ratio, Data Logging, USB Output, Single Type K Input, and Temperature Alarm User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight

More information

IR-829 Infrared Thermometer User Manual

IR-829 Infrared Thermometer User Manual IR-829 Infrared Thermometer User Manual Contents 1. Introduction...2 2. Features...2 3. Application...2 4. Safety...3 5. Field of View...4 6. Specifications...5 7. Meter Description...6 8. LCD Display

More information

Non-contact Forehead IR Thermometer

Non-contact Forehead IR Thermometer User s Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Non-contact Forehead IR Thermometer Model IR200 Introduction Congratulations

More information

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www. Model R2002 Infrared Thermometer Instruction Manual reedinstruments www com Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Operating Instructions...6-7 Battery

More information

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297 User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth Model

More information

Non-contact Forehead IR Thermometer

Non-contact Forehead IR Thermometer User s Manual Non-contact Forehead IR Thermometer Model IR200 Introduction Congratulations on your purchase of the Model IR200 IR Thermometer. This thermometer is intended for scanning groups of individuals

More information

UNIVERSAL MOISTURE TESTER HB-300. Operating Manual

UNIVERSAL MOISTURE TESTER HB-300. Operating Manual UNIVERSAL MOISTURE TESTER HB-300 Operating Manual Contents 1. UNIVERSAL MOISTURE TESTER HB-300...4 2. FEATURES... 5 3. SPECIFICATIONS...6 4. NOMENCLATURE... 7 5. DISPLAY SCREEN...8 6. OPERATION PANEL

More information

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related UltraTEV Locator Portable PD (Partial Discharge) investigation system Locates, measures and records PD activity in all substation assets including cables benefits Locating and measuring PD activity to

More information

LI-3000C Portable Area Meter

LI-3000C Portable Area Meter LI-3000C Portable Area Meter And LI-3050C Transparent Belt Conveyer Accessory FAST PRECISE EASY OPERATION LI-3000C Portable Area Meter Leaf Area of Living Plants or Detached Leaves in the Field or Laboratory

More information

DIGITAL OXYGEN METER. Model : DO-5510

DIGITAL OXYGEN METER. Model : DO-5510 DIGITAL OXYGEN METER Model : DO-5510 ATTENTION : Fill the Probe's Electrolyte at first. Intend to keep the DO probe under the best condition, when user receive the DIGITAL OXYGEN METER along the PROBE,

More information

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500 USER GUIDE Mini InfraRed Thermometer with Laser Pointer MODEL 42500 Introduction Congratulations on your purchase of the Model 42500 IR Thermometer. This thermometer makes noncontact (infrared) temperature

More information

SL 200 instrument can process the energy intensity emitted by the solar radiation in a precise place of the earth.

SL 200 instrument can process the energy intensity emitted by the solar radiation in a precise place of the earth. Solarimeter SL 200 Table of contents 1 Introduction...4 2 General information...4 2.1 Measured units...4 2.2 Use...4 3 Operating principle...5 3.1 Keyboard presentation...5 3.2 Instrument offers 3 groups

More information

PRORADAR X1PRO USER MANUAL

PRORADAR X1PRO USER MANUAL PRORADAR X1PRO USER MANUAL Dear Customer; we would like to thank you for preferring the products of DRS. We strongly recommend you to read this user manual carefully in order to understand how the products

More information

Heavy Duty CFM-CMM Thermo-Anemometer With built-in non-contact IR Thermometer and Laser Pointer Model HD300

Heavy Duty CFM-CMM Thermo-Anemometer With built-in non-contact IR Thermometer and Laser Pointer Model HD300 User Guide Heavy Duty CFM-CMM Thermo-Anemometer With built-in non-contact IR Thermometer and Laser Pointer Model HD300 Introduction Congratulations on your purchase of the Extech HD300 CFM Thermo-Anemometer.

More information

USER GUIDE. IR Thermal Scanner. Model IRT500

USER GUIDE. IR Thermal Scanner. Model IRT500 USER GUIDE IR Thermal Scanner Model IRT500 Introduction Thank you for selecting the Extech Model IRT500. The IRT500 Dual Laser IR Thermal Scanner is designed with a dual laser, an audible/visual alarm,

More information

OM-60-TH SERVICE LOGGER WITH TEMPERATURE/HUMIDITY/DEW POINT SENSOR GETTING STARTED

OM-60-TH SERVICE LOGGER WITH TEMPERATURE/HUMIDITY/DEW POINT SENSOR GETTING STARTED OM-60-TH SERVICE LOGGER WITH TEMPERATURE/HUMIDITY/DEW POINT SENSOR The OM-60-TH is a Service Logger with a temperature/humidity/dew point sensor. The OM-60-TH is specified for air use only. The sensor

More information

Smartphone RH/Temperature Probe Instruction Manual

Smartphone RH/Temperature Probe Instruction Manual Smartphone RH/Temperature Probe 800014 Instruction Manual 1 TABLE OF CONTENTS Introduction...3 Features...4 App Screen...5 Measurement Procedures...7 Care and Maintenance...14 Compatibility...14 Specifications...15

More information

Medidores de vibración salida RS232 Datalogger VT-8204 LUTRON manual ingles

Medidores de vibración salida RS232 Datalogger VT-8204 LUTRON manual ingles English usermanual VT-8204 Vibration Tachometer Your purchase of this VIBRATION TACHOMETER marks a step forward for you into the field of precision measurement. Although this VIBRATION TACHOMETER is a

More information

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER INTRODUCTION ENGLISH Thank you for purchasing the Safescan 1450 coin counter and sorter. For proper use and maintenance, we advise to read this user manual

More information

2 IN 1 DIGITAL COATING THICKNESS GAUGE MODEL - KM 118A OPERATION MANUAL LIST OF PRODUCTS

2 IN 1 DIGITAL COATING THICKNESS GAUGE MODEL - KM 118A OPERATION MANUAL LIST OF PRODUCTS LIST OF PRODUCTS Digital Multimeter Digital AC & AC/DC Clampmeter AC Clamp Adaptor AC/DC Current Adaptor Thermo Anemometer Thermo Hygrometer Distance Meter Digital Lux Meter Network Cable Tester Power

More information

Getting started with your NutriOpt On-site Adviser. Better feed choices today

Getting started with your NutriOpt On-site Adviser. Better feed choices today Getting started with your NutriOpt On-site Adviser Better feed choices today This manual explains how to get started with the NutriOpt On-site Adviser. To make the most of this innovative solution, please

More information

Studuino Color Sensor Manual

Studuino Color Sensor Manual Studuino Color Sensor Manual This manual explains the Studuino Programming Environment and how to use it. As the Studuino Programming Environment develops, this manual may be edited or revised. You can

More information

200 us/2 ms/20 ms/200 ms, TDS ( PPM ) Real time data logger, Data logger no., RS232 CONDUCTIVITY METER Model : YK-2005CD

200 us/2 ms/20 ms/200 ms, TDS ( PPM ) Real time data logger, Data logger no., RS232 CONDUCTIVITY METER Model : YK-2005CD 200 us/2 ms/20 ms/200 ms, TDS ( PPM ) Real time data logger, 16000 Data logger no., RS232 CONDUCTIVITY METER Model : YK-2005CD TABLE OF CONTENTS 1. FEATURES...1 2. SPECIFICATIONS... 2 2-1 General Specifications...2

More information

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A POWER ANALYZER Model : DW-6090A Your purchase of this POWER ANALYZER marks a step forward for you into the field of precision measurement. Although this POWER ANALYZER is a complex and delicate instrument,

More information

Canopy Interception and Leaf Area Index

Canopy Interception and Leaf Area Index Canopy Interception and Leaf Area Index metergroup.com/environment/products/accupar-lp-80-leaf-area-index/ Accurate canopy analysis in real time ACCUPAR LP-80 Measuring canopy density can be problematic

More information

Nikon D7100 Camera Kit. -Checklist and Operations Manual-

Nikon D7100 Camera Kit. -Checklist and Operations Manual- Airborne Digital Reconnaissance System (ADRS) Nikon D7100 Camera Kit -Checklist and Operations Manual- V4.2 October 21, 2014 National Headquarters, Civil Air Patrol 2 1.0 Equipment Pre-Mission Check 1.1

More information

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270 User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech IR270

More information

User Manual for SpectraCrop Plant Vitality and P-Tester

User Manual for SpectraCrop Plant Vitality and P-Tester User Manual for SpectraCrop Plant Vitality and P-Tester 1 Table of Content 1. Terms and Conditions... 3 2. Introduction... 4 3. SpectraCrop Plant Vitality and P-Tester... 6 3.1 Flow Chart... 6 4. How to

More information

Infrared Gun. Perfect For. Easy To Use. Features. Get Professional Results Every Time! Battery Installation. Model: IN1022

Infrared Gun. Perfect For. Easy To Use. Features. Get Professional Results Every Time! Battery Installation. Model: IN1022 Model: IN1022 Infrared Gun -76 to +1022 F/-60 to +550 C Perfect For Non-contact surface temperatures Easy To Use 1-second response Laser target illumination Backlit Data-hold One-button operation Features

More information

Bur3074 NADAMOO 2.4G Wireless & USB wired Barcode Scanner. Quick Start Guide

Bur3074 NADAMOO 2.4G Wireless & USB wired Barcode Scanner. Quick Start Guide Bur3074 NADAMOO 2.4G Wireless & USB wired Barcode Scanner Quick Start Guide In order to correctly use the bar code scanner, please read the instruction carefully and do not arbitrarily scan the settings

More information

Yara Water Solution. Installation Guide. Product summary: - Included components - Tools for setup - Installation overview

Yara Water Solution. Installation Guide. Product summary: - Included components - Tools for setup - Installation overview Yara Water Solution Installation Guide Product summary: - Included components - Tools for setup - Installation overview Step by step installation guide: - Mounting the Base Station - Preparing the field

More information

TABLE OF CONTENTS. Electromatic Equipment Co., Inc. -1-

TABLE OF CONTENTS. Electromatic Equipment Co., Inc. -1- TABLE OF CONTENTS 1.0 Introduction 2 1.1 Calibration curves 1.2 Explanation of calibration curves 2.0 Operating the instrument. 3 3.0 View of the instrument. 4 4.0 Menu.. 5 5.0 Other symbols and key functions..

More information

Psychrometer With IR DT-8896 Operation Manual

Psychrometer With IR DT-8896 Operation Manual Psychrometer With IR DT-8896 Operation Manual PROBE %RH/TEMP MAX MIN WB DP HOLD IRT C F MAX IR K TEMP HOLD MIN INTRODUCTION Thank you for purchase of the DT-8896 Psychrometer with IR Thermometer. This

More information

Temp. & humidity indicator

Temp. & humidity indicator Temp. & humidity indicator AH8008 Product Manual www.aosong.com 1 Product Overview AH8008 handheld multi-function temperature and humidity instrumentation consists of two parts: the AH8008 instrument and

More information

1.0 PURPOSE AND SCOPE

1.0 PURPOSE AND SCOPE Questa Rock Pile Stability StudySOP 51v2 Page 1 STANDARD OPERATING PROCEDURE NO. 51 COLLECTING THERMAL IMAGES REVISION LOG Revision Number Description Date 51v0 Original SOP by HRS and JMS 6-7-2004 51v1

More information

User Manual. This User Manual will guide you through the steps to set up your Spike and take measurements.

User Manual. This User Manual will guide you through the steps to set up your Spike and take measurements. User Manual (of Spike ios version 1.14.6 and Android version 1.7.2) This User Manual will guide you through the steps to set up your Spike and take measurements. 1 Mounting Your Spike 5 2 Installing the

More information

GC723A / GC724B Cable and Antenna Analyzer

GC723A / GC724B Cable and Antenna Analyzer www.gctm.net GC723A / GC724B Cable and Antenna Analyzer GC723A / GC724B Cable and Antenna Analyzer Introduction A large number of abnormal cell site problems are typically caused by the antenna system,

More information

2.7 GHz FREQUENCY COUNTER with TCXO

2.7 GHz FREQUENCY COUNTER with TCXO 2.7 GHz FREQUENCY COUNTER with TCXO TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications... 1 2-2 Table for Resolution & Sampling Time... 3 3. FRONT PANEL DESCRIPTION...4

More information

High Temperature InfraRed Thermometer with Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer User s Manual High Temperature InfraRed Thermometer with Laser Pointer MODEL 42545 42545 Introduction Congratulations on your purchase of the Model 42545 IR Thermometer. The 42545 is capable of non-contact

More information

Mx-RPW Room Control Module (Built-In Occupancy Sensor)

Mx-RPW Room Control Module (Built-In Occupancy Sensor) Wireless Room Controller Application Solar-powered, self-learning room sensor with LCD and smart communication management for measuring room temperature, independent generation of utilization time profiles

More information

MICROSCANNER TM D-Series

MICROSCANNER TM D-Series MICROSCANNER TM D-Series High Performance Models I N S T R U C T I O N M A N U A L C O R P O R A T I O N 818098 400 Pleasant Street Watertown, MA 02472 (617) 923-9900 800-442-3006 FAX: 617-923-9911 C O

More information

Operation Guide 3452

Operation Guide 3452 MA1804-EA Contents Before Getting Started... Button Operations Mode Overview Charging the Watch Solar Charging Charging with the Charger Charging Time Guidelines Checking the Charge Level Power Saving

More information

DC Resistance Meters 2840 Series

DC Resistance Meters 2840 Series Data Sheet DC Meters Touch screen to zoom, select, and enter values The DC resistance meters feature high accuracy and resolution measurements in the milliohm range. Both meters are ideally suited for

More information

QUANTUM Qflash MODEL T OPERATING INSTRUCTIONS

QUANTUM Qflash MODEL T OPERATING INSTRUCTIONS QUANTUM Qflash MODEL T OPERATING INSTRUCTIONS 1.0 DESIGNATIONS 1. Removable Reflector, two positions Normal and Wide angle. 2. Flash-tube 3. Bounce Head, Rotates 180º 4. Swivel Head, Rotates ± 90º 5. Sensor

More information

Non-Contact Infrared Thermometers. 8818H/8819H/8828H series. Operation Manual

Non-Contact Infrared Thermometers. 8818H/8819H/8828H series. Operation Manual Non-Contact Infrared Thermometers 8818H/8819H/8828H series Operation Manual 1 TABLE OF CONTENTS INTRODUCTION..3 FEATURES...3 WIDERANGEAPPLICATION...3 SAFETY..3 DISTANCE & SPOT SIZE 3 SPECIFICATIONS 4 FRONT

More information

Contents. Chapter 1 Brief Introduction of K9 series Chapter 2 K9 series mainframe The appearance of mainframe Interface...

Contents. Chapter 1 Brief Introduction of K9 series Chapter 2 K9 series mainframe The appearance of mainframe Interface... Contents Chapter 1 Brief Introduction of K9 series... 1 Chapter 2 K9 series mainframe... 2 2.1 The appearance of mainframe... 2 2.2 Interface... 2 2.3 The installation of battery... 3 2.4 Guiding light

More information

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

UltraTEV Locator Portable Partial Discharge (PD) investigation system. UltraTEV Locator Portable Partial Discharge (PD) investigation system Locates, measures and records PD activity in all substation assets including cables www.eatechnologyusa.com Benefits Locating and measuring

More information

RQflex 2. Manual English

RQflex 2. Manual English RQflex 2 Manual English Contents 1 Introduction 3 2 Description of the instrument 5 display, keys 6 technical data 8 3 Setting up the instrument 9 insertion of batteries 10 setting the time and date 11

More information

Measuring Insulating Material Resistivity Using the B2985A/87A

Measuring Insulating Material Resistivity Using the B2985A/87A APPLICATION NOTE Measuring Insulating Material Resistivity Using the B2985A/87A Keysight B2985A/B2987A Electrometer/High Resistance Meter Introduction The Keysight B2985A and B2987A Electrometer/High Resistance

More information

BandMaster V Manual. Installation

BandMaster V Manual. Installation BandMaster V Manual Installation Installing and configuring the BM-5 BandMaster V is a simple process. All the configuration process is done from the front panel. Installation and configuration steps are

More information

FLIR Tools for PC 7/21/2016

FLIR Tools for PC 7/21/2016 FLIR Tools for PC 7/21/2016 1 2 Tools+ is an upgrade that adds the ability to create Microsoft Word templates and reports, create radiometric panorama images, and record sequences from compatible USB and

More information

OPERATION MANUAL INFRARED THERMOMETER FIRT 500

OPERATION MANUAL INFRARED THERMOMETER FIRT 500 OPERATION MANUAL INFRARED THERMOMETER FIRT 500 Features: Precise non-contact measurements Built-in laser pointer Automatic selection range and Resolution to 0.1 or 1 / switchable button Automatic Data

More information

3 AXIS RF ELECTROMAGNETIC FIELD METER

3 AXIS RF ELECTROMAGNETIC FIELD METER 50 MHz to 3 GHz Radio Frequency Radiation Meters Electromagnetic Field strength measurement 3 AXIS RF ELECTROMAGNETIC FIELD METER Model : EMF-819 Your purchase of this RF EMF METER marks a step forward

More information

How to Operate the Testo 870 thermal imager

How to Operate the Testo 870 thermal imager How to Operate the Testo 870 thermal imager Content 1. Technical data testo 870-1 & 870-2 2. Technical overview (Fixed focus) 3. Interface/internal memory 4. Inserting the battery 5. Operation of the testo

More information

PH METER OPERATION MANUAL. Model : PH-208

PH METER OPERATION MANUAL. Model : PH-208 PH METER Model : PH-208 Your purchase of this PH METER marks a step forward for you into the field of precision measurement. Although this PH METER is a complex and delicate instrument, its durable structure

More information

Grain & Seed Moisture Tester PM-600. Operating Manual

Grain & Seed Moisture Tester PM-600. Operating Manual Grain & Seed Moisture Tester PM-600 Operating Manual CONTENTS 1. Specifications... 2 2. Names of Parts... 3 3. Keyboard... 4 4. Display... 5 5. Before Measurement... 6 6. Measurement Operation... 7 7.

More information

An NDVI image provides critical crop information that is not visible in an RGB or NIR image of the same scene. For example, plants may appear green

An NDVI image provides critical crop information that is not visible in an RGB or NIR image of the same scene. For example, plants may appear green Normalized Difference Vegetation Index (NDVI) Spectral Band calculation that uses the visible (RGB) and near-infrared (NIR) bands of the electromagnetic spectrum NDVI= + An NDVI image provides critical

More information

English. Money Counter. Coin and banknote counter. DEUTsCH. Manual

English. Money Counter. Coin and banknote counter. DEUTsCH. Manual ITALIANO ESPAÑOL FRANçAIS NEDERLANDS English Money Counter DEUTsCH Coin and banknote counter Manual Money Counter for Coins and Banknotes Introduction Thank you for choosing the Money Counter series. The

More information

THERMAL PROFILE OF HOT MIX ASPHALT

THERMAL PROFILE OF HOT MIX ASPHALT Test Procedure for THERMAL PROFILE OF HOT MIX ASPHALT TxDOT Designation: Tex-244-F Effective Dates: March 2010 April 2011. Texas Department of Transportation 1. SCOPE 1.1 Use this test method to obtain

More information

Spectral Reflectance Sensor SRS-NDVI

Spectral Reflectance Sensor SRS-NDVI The Spectral Reflectance Sensor NDVI continuously monitors the NDVI of our plant canopy. Measure NDVI or PRI vegetation indices at the plot or plant stand scale. Non-destructive sampling of canopy greenup,

More information

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

CD4 Series with linear image sensor and electronic shutter provides accurate measurement. 3 series Series with linear image sensor and electronic shutter provides accurate measurement. Laser displacement sensor features easy setup and operation. High accuracy of.1µm resolution and ±.1% F.S.

More information

MT3500 Hand-Held Engine Analyzer Safety Operation Regulations

MT3500 Hand-Held Engine Analyzer Safety Operation Regulations MT3500 Hand-Held Engine Analyzer Safety Operation Regulations - 1 - Chapter One Introduction A. Notice of Usage: MT3500 Hand-Held Engine Analyzer must be operated by trained professionals, who must know

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

Digital insulation tester

Digital insulation tester Digital insulation tester C.A 6505 > > Insulation at 5 kv > > Wide measurement range from 10 kω to 10 TΩ > > Large backlit LCD screen, with digital display and bargraph > > Fixed test voltages and programmable

More information

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL Confirm contents of package: 1 sensor, 1 cable, 1 wide lens (default), 1 narrow lens, mounting template, User s Guide. Install the sensor at the desired

More information

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS 1.0 DESIGNATIONS T2 AND X2 1. Removable Reflector, two positions Normal and Wide angle. 2. Flash-tube 2A. Modeling Lamp (for Model X2 only) 3. Bounce Head,

More information

Fluke 570 Series Infrared Thermometers:

Fluke 570 Series Infrared Thermometers: Fluke 570 Series Infrared Thermometers: Adding more precision to non-contact temperature measurement Application Note 572 574 This application note describes the Fluke 570 Series, the most advanced infrared

More information

User Friendly Interface means: Power through Simplicity

User Friendly Interface means: Power through Simplicity W h a t i s t h e T & D T R - 5 i S e r User Friendly Interface means: Power through Simplicity The TR-5i Series is a family of data loggers designed to measure and record a variety of items: from temperature

More information

WiFi Photo & Document Scanner User Guide

WiFi Photo & Document Scanner User Guide WiFi Photo & Document Scanner User Guide CONTENTS Safety precautions What s in the box Product diagram Operation / charge the battery Download and install iscan Air App FREE Connect to a WiFi network Scan

More information

multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER

multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER Model : DI-6400 Your purchase of this INSULATION TESTER marks a step forward for you into

More information

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer Advanced documenting multifunction calibrator thermometer, most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer

More information

3 PHASE DIGITAL POWER CLAMP METER USERS MANUAL

3 PHASE DIGITAL POWER CLAMP METER USERS MANUAL PHASE DIGITAL POWER CLAMP METER USERS MANUAL CONTENTS Safety Precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - Safety Information - - - - - - - - - - - - - - - - - - - - - - - - - - - Safety

More information

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS 2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS Contents Section Brief Description... 1 Where and why it is used... 1.1 Induced Measureable Parameters... 1.2 Hardware

More information

INSTRUCTION MANUAL INF Fax: (503)

INSTRUCTION MANUAL INF Fax: (503) INSTRUCTION MANUAL INF151 1-800-547-5740 Fax: (503) 643-6322 www.ueiautomotive.com email: info@ueitest.com Introduction Congratulations on your purchase of the INF151 infrared thermometer. Like all UEi

More information

Wireless Handy Scanner

Wireless Handy Scanner User Guide Works with iscanair Go Scanner App Wireless Handy Scanner For smartphones, tablets, and computers Wi-Fi 802.11g/n supported All trademarks are the property of their respective owners and all

More information

The Standard for over 40 Years

The Standard for over 40 Years Light Measurement The Standard for over 40 Years Introduction LI-COR radiation sensors measure the flux of radiant energy the energy that drives plant growth, warms the earth, and lights our world. The

More information

Electrical and HVAC Test Tools

Electrical and HVAC Test Tools Electrical and HVAC Test Tools The New Fluke 330 Series Clamp Meters New Fluke Products! 330 Series Clamp Meters 1520 MegOhmMeter 43B Power Quality Analyzer 170 Series Digital Multimeters 110 Series Digital

More information

Studuino Icon Programming Environment Guide

Studuino Icon Programming Environment Guide Studuino Icon Programming Environment Guide Ver 0.9.6 4/17/2014 This manual introduces the Studuino Software environment. As the Studuino programming environment develops, these instructions may be edited

More information

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer Advanced documenting multifunction calibrator thermometer , most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer

More information

ADAE portable X ray machine Operation manual

ADAE portable X ray machine Operation manual ADAE portable X ray machine Operation manual CONTENTS ABOUT THE SYMBOL----------------------------------------------------------3 INTRODUCTION-----------------------------------------------------------------4

More information

User Manual for Grass Snap (Android Version)

User Manual for Grass Snap (Android Version) User Manual for Grass Snap (Android Version) Grass Snap is a useful tool when monitoring your pastures and grasslands. Grass Snap will take you through the monitoring process step-by-step. Grass Snap meets

More information

SCATT Biathlon shooting trainer User s Manual

SCATT Biathlon shooting trainer User s Manual SCATT Biathlon shooting trainer User s Manual Russia, Moscow, ZAO SCATT Internet: www.scatt.com E-mail: info@scatt.com Tel/Fax: +7 (499) 70 0667 Please read the User s Manual before installation, operation,

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Sodium Thiosulphate and hydrochloric acid

Sodium Thiosulphate and hydrochloric acid Sodium Thiosulphate and hydrochloric acid Introduction The rate of reaction can be altered by varying temperature or concentration, or by changing the surface area of a solid reactant, or by adding a catalyst.

More information

FLUO invisible Ink Densitometer Instruction Manual

FLUO invisible Ink Densitometer Instruction Manual FLUO instruction manual Firmware Version 2.02 FLUO invisible Ink Densitometer Instruction Manual FLUO Manual v2.02 GB.docx 1 / 13 6/29/2018 Content FLUO... 3 Safety Instructions... 5 How to use the FLUO...

More information

CashConcepts CCE 4000

CashConcepts CCE 4000 CashConcepts CCE 4000 Coin Counter and Sorting Machine User Manual Introduction Thank you for choosing the CCE 4000. This coin counting and coin sorting machine is designed to simplify the daily cash or

More information

Yara Water Solution. Installation Guide. Product summary: - Included components - Tools for setup - Installation overview

Yara Water Solution. Installation Guide. Product summary: - Included components - Tools for setup - Installation overview Yara Water Solution Installation Guide Product summary: - Included components - Tools for setup - Installation overview Step by step installation guide: - Mounting the Base Station - Preparing the field

More information

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers MIT400/2 Designed for electrical and industrial testing Insulation testing up to 1000 V and 200 GΩ range Stabilized insulation test voltage (New) Single range, faster continuity testing from 0.01 Ω to

More information

SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter. The most advanced Transformer Winding Resistance Meter injects up to 25A DC...

SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter. The most advanced Transformer Winding Resistance Meter injects up to 25A DC... SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter The most advanced Transformer Winding Resistance Meter injects up to 25A DC......TRM 25 The Product TRM 25 / TRM 25+ : Advanced Transformer Winding

More information

CD-3600/3601 (U/R) 2D Image Scanner Quick Setup Guide

CD-3600/3601 (U/R) 2D Image Scanner Quick Setup Guide CD-3600/3601 (U/R) 2D Image Scanner Quick Setup Guide Package Contents CD-3600U/3601U 2D image scanner USB cable Quick setup guide CD-3600-SK/CD-3601-SK 2D image scanner USB cable for SK-300 Quick setup

More information

User Manual. P6 Barcode Scanner. English

User Manual. P6 Barcode Scanner. English User Manual P6 Barcode Scanner English Contents IMPORTANT NOTICE 4 Safety Precaution 4 Maintenance Precaution 4 Overview of Inateck P6 barcode Scanner 4 Appearance 4 Features of the Scanner 5 Introduction

More information

Printing Humidity/Temperature Meter

Printing Humidity/Temperature Meter Printing Humidity/Temperature Meter INSTRUCTION MANUAL I. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified

More information

PHOTO FRAME STRING LIGHTBOXES

PHOTO FRAME STRING LIGHTBOXES PFL-500CD PHOTO FRAME STRING LIGHTBOXES Candlenut Distressed Wood Frame USER MANUAL NEED HELP? Call our help line 1-866-765-3686 or visit us at: www.polaroidlightboxes.com Polaroid, Polaroid & Pixel, Polaroid

More information

MicroLab 500-series Getting Started

MicroLab 500-series Getting Started MicroLab 500-series Getting Started 2 Contents CHAPTER 1: Getting Started Connecting the Hardware....6 Installing the USB driver......6 Installing the Software.....8 Starting a new Experiment...8 CHAPTER

More information

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000 The ideal K-12 science microscope solution User Guide for use with the Nova5000 NovaScope User Guide Information in this document is subject to change without notice. 2009 Fourier Systems Ltd. All rights

More information

INDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System...

INDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System... USER GUIDE INDEX Accessories and Components... 4 System Unit and Joystick... 6 Assembly and Charging the Battery... 9 Using with LED System... 11 What is Ground Setting and How It Is Done... 14 Ground

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information