Finesse Profiles. Nailstrip

Similar documents
TYPICAL BARGE DETAIL - CROSS SECTION

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

Construction details: Master-C type profiles and joints:

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

900 SERIES WALL PANELS

Pipe penetration refer CT15. Viking CertainTeed Shingles General Roof details

ProSnap 100 STANDARD DETAILS

Tuff Rib Panel Installation Specifications

REGAL. Installation Manual

TABLE OF CONTENTS A-1

Table of Contents Light Gauge Metal Roof & Wall Panels

ALPINE TRAY. To get the best from this product please follow these recommendations.

2 ½ Corrugated Panel Installation Specifications

APRON FLASHING NOTES: SHEET METAL APRON FLASHING WITH HEMMED EDGE RAGGLE SEALANT UNDERLAYMENT TURNED UP WALL

PBR Panel Installation Specifications


SLATE & SHINGLE INSTALLATION

DETAIL MANUAL for Standing Seam / Image II

TABLE OF CONTENTS A. PBR

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

400 SERIES VERTICAL INSTALLATION

Best Buy Metals Toll Free / Phone / Fax

HILAND TRAY FORM AND FUNCTION MATERIAL SPECIFICATIONS DESIGN GUIDE ROOFING I WALLING

Global Roofing Solutions Klip-Lok 700

Global Roofing Solutions Klip-Lok 406 Aluminium

STRATCO GABLE HOMESHED STRATCO GABLE HOMESHEDS STUBBIE INSTALLATION GUIDE

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

Tuff-Rib Install Guide

Euro-Tray Roll Cap. Specific Profile Data Sheet BACK. Table of Contents. Technical Drawing File Downloads

SHED PACK Step 1: Choose your shed type.

Global Roofing Solutions Klip-Tite

Assembly instructions

DW HORIZONTAL INSTALLATION

SpeedDeck. Fixing and Handling Guide

Global Roofing Solutions Brownbuilt

Talk to us, THE SMART ROOF PEOPLE Visit or Global Roofing Solutions Brownbuilt

Klip-Lok 406 Aluminium

KS SERIES - VERTICAL INSTALLATION

DUTCH GABLE FREESTANDING CARPORT

Steel Roofing & Siding INSTALLATION GUIDE

Kocked Down with Ends Assembled

SHED PACK. Sheds are commonly constructed using portal frames.

Extrusions GB-3-IN01. Updated: Scale: REV: - This Drawing is Protected by Copyright Altus NZ Ltd.

Everbright E610 polycarbonate light panels Installation guidance

Ekoroof LiteTile Dimensions

SpeedZip. Fixing and Handling Guide

Trapezoidal Roof KS1000 RW Installation Guide

Table of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8

MINI/MAXI-BATTEN. Panel Information. Detail Conditions. Flashing Profiles

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

Global Roofing Solutions Klip-Tite

BARRELL VAULT BATTENLESS

GLOSSARY OF TERMS SECTION 8

DW VERTICAL INSTALLATION

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

Tuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311

Phone (662) Fax (662) DETAIL MANUAL. and guide to Reed s Metals products

Guardian warm roof conversion system. Installation Guide

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE

INSTALLATION GUIDE LEARN MORE AT DECRA.COM

Safety Glasses Safety Gloves Ladders Measuring Tape Spirit Level String Line. Tin-Snips Rivet Gun Caulking Gun Silicone Socket Set

FLASHINGS FLASHINGS REVSPEC. Valley Gutter Example V1 V2 V3 V4 V5 V6. Ridge Capping. Low Profile Ridge Capping CUSTOM MADE VALLEY GUTTER

3/ /

MANUAL. Perma-Loc & Secure-Seam. Standing Seam Roofing Panels & Accessories. and guide to Town and Country Metals products

TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT

INTRODUCTION. EqunioxRoof.com. Pro Tip

401 SW 33rd Ave Ocala, FL

Ensure there is reasonable access for materials and working space, ensure the shed site is level and consider the disposal of run-off water.

Table of Contents. Roof to Head Wall w/ Side Flashing DECRA Shake XD Roof Overview Roof Penetration - Pipes & Vents...

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

KS42 MF SERIES - HORIZONTAL INSTALLATION

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

INSTALLATION DETAILS

YWY M08 The new VELUX solution

Installation Manual. This installation is for the Odyssey H1800 Series Ventilation System.

Inspire Aledora Slate Application Guidelines

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

Installation guide for 20/20

CROSSBAR RAFTER ISOMETRIC

PROVEN DEPENDABLE SUSTAINABLE

ONDUVILLA. The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights

This installation guide has been created to assist in constructing a Liniar conservatory roof from a kit format.

UL Construction No. 254

ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION

PRODUCT EVALUATION Effective July 1, 2009 RC-204

DECRA Shingle Installation Guidelines

MetroCOTTAGE Shingle

Austin Standing Seam Awning Assembly and Installation Instructions. Assembly Instructions

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988

OWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS

Shingle Installation Guide

INSTALLATION GIUDE.

Barrel Vault Counter Batten and Batten

TYPICAL FRAMING AND STITCH FASTENER PATTERNS FOR MAX-RIB PANELS

MasterRib. Installation Manual. July Toll-Free (888) MTL-ROOF. PO Box 229 Fayetteville, NC Rev.

Nutec Bigsix Roofing Accessories

Transcription:

Installation Details Profile and Lap Detail 265/465 38mm NAILSTRIP *other widths available CD GRADE PLYWOOD 19mm STRUCTURE SILICONE * MIN 20mm VENTILATION GAP * WHEN ROOF PITCH IS UNDER 7.5 OR TOTAL COMBINED SHEET LENGTH IS OVER 5 METRES. #10-12 X 25mm WAFER HEAD WOOD SCREW @ 450mm CTS Figure NS ID 004

Installation Details: Low Eave/Gutter or Aluminium CD GRADE PLYWOOD 19mm SCREWS TO EDGE OF SHEET NAILSTRIP PANEL RIB CLOSURE PAN TURNED DOWN TO DRIP INTO GUTTER CUT BACK RIB ON ANGLE. EDGE FOLDED TO CLOSE. POP RIVET AND SEAL WITH SILICONE. POP RIVET TURN DOWN PAN TO FORM DRIP INTO GUTTER NAILSTRIP SCREWS TO EDGE OF SHEET FASTENERS #10-12 X 25mm WAFER HEAD WOOD SCREW W/ #2 PHILLIPS @ 100mm CTS. MIN 20mm VENTILATION GAP EAVES GUTTER EXT GUTTER BRACKET Figure NS ID 005

NAILSTRIP CUT BACK RIB ON ANGLE. EDGE FOLDED TO CLOSE. POP RIVET AND SILICONE SEAL PAN TURNED DOWN - 25mm POLE PLATE FLASHING #10-12 X 25mm WAFER HEAD WOOD SCREW W/ #2 PHILLIPS SLOT @ 100mm CTS. CD GRADE PLYWOOD 19mm WITH ROUTED REBATE MIN 20mm VENTILATION GAP Figure NS ID 006 FASTENER FIX THROUGH TO PLY SUBSTRATE AT MIN 900 C/C 175mm 25mm NOTCHED OVER RIBS BARGE CAPPING NAILSTRIP CD GRADE PLYWOOD 19mm LOW PROFILE FASTENER (BY INSTALLER) FOLD UP END OF SHEET SEE SHEET - TYPICAL STOP END Figure NS ID 007

Installation Details: Typical Ridge CD GRADE PLYWOOD 19mm HEX HEAD FIXING FOLD UP END OF SHEET SEE SHEET - TYPICAL STOP END 150 mm 25mm VENTILATION GAP ONE-PIECE RIDGE CAPPING FIX THROUGH TO SUBSTRATE AT MIN 900 C/C TVP C/BOND NAILSTRIP Figure NS ID 008

Installation Details: Typical Barge BARGE CD GRADE PLYWOOD 19mm MINIMUM 20mm VENTILATION 40mm BATTEN BARGE FLASHING BARGE Figure NS ID 009 BARGE FLASHING BARGE BARGE CD GRADE PLYWOOD 19mm MINIMUM 20mm VENTILATION Figure NS ID 010

Installation Details: One slope ridge TURN UP END PANEL SEE SHEET 2-2 RIDGE CAPPING FASTENER NAILSTRIP FASTENER MINIMUM 20mm VENTILATION GAP Figure NS ID 011

Installation Details: Typical Apron Flashing to Wall FOLDED APRON FLASHING WALL STRUCTURE CHASE INTO WALL NEUTRAL SEALANT FOLDED FLASHING 10mm MIN 10mm MIN 40mm BATTEN IF OVER 240mm 150mm MIN CD GRADE PLYWOOD 19mm SCREW Figure NS ID 012

Installation Details: Typical Valley Over 7.5 FASTENERS #10-12 X 25mm WAFER HEAD WOOD SCREW W/ #2 PHILLIPS @ 100mm CTS. CD GRADE PLYWOOD 19mm WITH ROUTED REBATE C/BOND VALLEY RIB CLOSURE TURNED DOWN MINIMUM 20mm VENTILATION GAP NAILSTRIP PANEL RETURNED EDGE 25mm REBATE PLY Figure NS ID 013 REBATE UNDER VALLEY RIBS VALLEY CENTRE OF VALLEY GUTTER TURNDOWN PLAN VIEW Figure NS ID 014

Installation Details: Typical Valley Over 7.5 (cont.) CUT BACK RIB ON ANGLE. EDGE FOLDED TO CLOSE. Figure NS ID 015 Installation Details: Typical Valley Under 7.5 PAN TURNED DOWN VALLEY 25mm BYCELL COMPRESSED STRIP NAILSTRIP PANEL RIB CLOSURE CD GRADE PLYWOOD 19mm WITH ROUTED REBATE MINIMUM 20mm VENTILATION GAP Figure NS ID 016

Installation Details: Typical Valley Under 7.5 (cont.) GUTTER RIBS VALLEY CENTRE OF VALLEY TURNDOWN Figure NS ID 017 PLAN VIEW Figure NS ID 018

Installation Details: Typical Ventilation CUT BACK RIB ON ANGLE. EDGE FOLDED TO CLOSE. NAILSTRIP CD GRADE PLYWOOD 19mm VENTILATION STEELWORK BY OTHERS PURLINS BY OTHERS Figure NS ID 019

Installation Details: Typical Panel Turndown 1. Panels requiring field hemmed ends should be fabricated 25mm longer than the finished panel length. Valley conditions must be field cut to the appropriate angle. 2. Cut back panel joints 25mm. 3. Place protruding pan into the panel hemming tool. The front edge of the tool must rest against the notched joint legs on both sides. 4. While maintaining pressure against the panel joints, rotate the hemming tool as close to 90 as possible. AL PANEL TURN-DOWN 25 CUT RIBS BACK 25mm PANEL HEMMING TOOL Figure NS ID 020

Installation Details: Typical Stop End 1. Place pan into the panel stop end tool. The front edge of the tool must rest between the ribs. 2. While maintaining pressure against the panel, rotate the stop end tool as close to 90 as possible. 3. Inspect completed bend. OP END 25 90 STOP END DETAIL PANEL WITH STOP END PANEL STOPEND TOOL Figure NS ID 021