Bulletin -P Product Selection/ Accessories Units Description DX Arrangement DX K Continuous Carrying Current [A] No cartridge Cat. No. -PLL -PLL AC-Operated Units -PKLL DY DY K DX Reset Input DX K No cartridge DC-PLL DC-PLL DC-Operated Units DC-PKLL DY AC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. -PLL becomes Cat. No. -PLLA. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Hz - - - - - - - - B B A B B B B B B B B A A A B A A A A A A A Optimized for V, Hz. Operates satisfactorily at V, Hz. Optimized for V, Hz. Operates satisfactorily at V, Hz. DC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. DC-PLL becomes Cat. No. DC-PLLZ. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. - - - - Z Z Z Z Z Z Z Z Z Z Z Z Z Mounting Strip Cat. No. -MP Cat. No. -DRA DY Description Relays per Strip Pkg. Quantity Cat. No. -MP Simplifies panel layout. These indexed strips are easily cut to the required length and bolted, riveted, or spot-welded in place. -MP Relays are installed adjacent to one another on the mounting strip with the captive mounting screws provided. Rows of relays on form their own wiring trough. Can be used with the following relays: P, -PK, PH, S-P, N, -R, -RTC -MP -MP DIN Rail Adapter Can be used with the following relays: Bulletin P, -PK, -PH, S-P, -N, -R, -RTC K -DRA DIN (#) symmetrical hat rail x. x m -DR -DR Type Enclosure Use for all Bulletin -P, -PH, and -PK relays except - and - pole DC relays or - and -pole DC Bulletin -PH relays. -N Type /X Enclosure For - and -pole Bulletin -P, -PH, -N, and -R relays and - pole Bulletin -PH relays. -N Cat. No. -N Type & Enclosure For - and -pole Bulletin -P, -PK, -N, and -R relays and - pole Bulletin -PH relays. conduit hub; top and bottom. -N -
Bulletin -P Product Selection ing Relays Factory-Assembled Bulletin -PL ing Relays Converts all poles to latching AC latch coil max. six poles latching DC latch coil max. five poles latching ing relays have two coils latch coil is the relay coil, reset coil is on the latch attachment /reset coils can have two AC coils, two DC coils, or one AC and one DC coil (e.g., latch with AC power, unlatch with DC battery) Bulletin -P Standard Contact Cartridge AC-Operated Relays DC-Operated Relays Contacts Open Type Mount with Open Type Mount with Open Type DIN Rail Mount with N.O. N.C. Contact Arrangement and Markings Cat. No. Contact Arrangement and Markings Cat. No. Cat. No. -PL DC-PL DC-PLD -PL DC-PL DC-PLD -PL DC-PL DC-PLD -Pole Relay -Pole Relay AC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. - PL becomes Cat. No. -PLA. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Relays with latch attachments: if the latch attachment coil is to be a different voltage other than the relay coil, add a second coil code suffix. Example: Cat. No. -PLAA. Only one suffix is required if both coils are the same voltage. Hz - - - - - - - - B B A B B B B B B B B A A A B A A A A A A A Optimized for V, Hz. Operates satisfactorily at V, Hz. Optimized for V, Hz. Operates satisfactorily at V, Hz. DC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. DC- PL becomes Cat. No. DC-PLZ. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. - - - - Z Z Z Z Z Z Z Z Z Z Z Z Z An open or failed unlatch control circuit will fail to unlatch the relay. For this reason, a mechanical latch unit should not be used where protection is needed against automatic restart after a power failure or where reliability to a control function is critical to safety. Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. Overlap contacts: To order a relay containing one pair: Use Cat. No. -PTZ. To order a relay containing two pairs: Use Cat. No. -PTZ. N.O. contact closes before N.C. contact opens. AC Ratings: NEMA A, DC Ratings: P. Location of contacts in -pole relays. Location of contacts in -pole relays: -pole relay plus the contacts indicated. -
Bulletin -P Specifications Contact Rating Continuous Ratings Make/Break Type -P, PL, PT -PK, PKL, PKT -PH Additional Contact Ratings for AC single-phase loads A @ V AC A @ V DC Electrical A @ V AC A @ V DC A @ V AC A @ V DC AC NEMA A x NEMA A x NEMA A DC NEMA P x NEMA P x NEMA P Hp @ V AC - N.O. Hp @ V AC - N.O./N.C. Hp @ V AC - N.O./N.C. A Resistive Heating to V AC A Tungsten Lighting Load to V AC Hp @ V AC - N.O. Hp @ V AC - N.O./N.C. Hp @ V AC - N.O./N.C. A General Use At. PF to V AC A Tungsten Lighting Load to V AC DC Current Ratings Make/Break Cartridge Cat. No. -CP Cartridge Cat. No. -CPM Cartridge Cat. No. -CPH Volts DC Contacts in Series W W W W W W DC Switching A. A. A. A. A. A A A. A. A. A. A A A. A. A. A. A A A A A. A. A A A A A. A. A A A A A. A. A A A. A. A A A A. A. A A A A. A. A A A. A. A A A A. A. A A A A. A. A AC % % % Coil Voltage DC % % % Range Battery Charging % % % Hz Hz Hz Hz Hz Hz Coil A Inrush VA VA VA VA VA VA Consumption C Sealed.VA VA. VA VA.VA VA P-PH-PK D Inrush.VA.VA.VA C Sealed.VA.VA.VA PLL - PKLL Inrush VA.VA VA.VA VA.VA AC Unit Sealed.VA.VA.VA.VA.VA.VA PLL - PKLL Unlatch VA VA DC Unit Intermittent W W Reset Time PT PKT ms ms Minimum Pulse PLL PKLL ms ms Operating Time Life Contact Arrangement Pickup Dropout DC ms DC ms Up to Poles, Convertible to N.O. or N.C. ( N.C. Maximum) DC ms DC ms million operations Construction Up to Poles, Convertible to N.O. or N.C. ( N.C. Maximum) DC ms DC ms Up to Poles, Convertible to N.O. or N.C. ( N.C. Maximum) Contact Material Nickel Silver Silver Cadmium Oxide Silver Cadmium Oxide Mounting Environmental Temperature Operating + C ( F) + C ( F) + C ( F) Storage + C ( F) + C ( F) + C ( F) Certifications CSA Certified, CSA File #LR, UL Listed, UL File #E, Guide NKCR, CE Certified, ABS Standards UL, CSA C. No., EN/IEC -, -- Wire Terminations Wire size per UL/CSA # AWG () # AWG Tightening Torque lb in (.. N m) Temperature inside the panel. Average value for all coils within range. For values on a specific coil voltage, contact your local Rockwell Automation sales office or Allen-Bradley distributor. -
Bulletin -P Specifications Operating Coils Bulletin Bulletin -P-PH-PK Relays Bulletin -PLL-PKLL s Coil Volts Bulletin -P, -PK -pole, Bulletin -PH -pole AC Bulletin -PLL PKLL AC Bulletin -P-PK -pole, Bulletin -PH -pole DC Hz Hz Hz Hz PA PA PL PL PD PD PA PA PL PL PD PA PL PD ( ) PA PL PA PL Bulletin -P Operating Coil PD PA PL PD PA PL PA PA PL PA PA PL PL PD PD PA PA PL PA PL PA PL Bulletin -PL Unlatch Coil and Magnet Assembly PA PL PA PL PD PA PL PD Coils for AC relays cannot be used in DC relays and vice versa. This coil is optimized for V, Hz applications and will operate satisfactorily at V, Hz. This coil is optimized for V, Hz applications and will operate satisfactorily at V, Hz. This coil is designed and marked for use at V DC. -
Bulletin -P Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Bulletin -P, -PH and -PK Relays. (-/). (-/) / - and -pole Bulletin -P, -PK Relay -pole Bulletin -PH Relay Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb) AC. (-/) - and -pole Bulletin -P or -PK Relay or -pole Bulletin -PH Relay with Pneumatic Time Delay Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb). (-/) - and -pole Bulletin -P, or -PK Relay -pole Bulletin -PH Relay Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb). (-/) - and -pole Bulletin -P or -PK Relay or -pole Bulletin -PH Relay with Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb) Cat. No. - and -pole Bulletin -P, DIN Rail Adapter or -PK Relay -pole Bulletin -PH Relay Approximate Shipping Weight: AC. kg (. lb), DC. kg (. lb). (-/) # Screws (Captive) for Bulletin -P, -PH, -PK, -N, -NM, -R, -RM, -RT, -RTA Relays Secure the mounting strip with two screws at each end relay position. Use a minimum of one screw at the rd, th, th, etc., relay positions. Alternate between upper and lower horizontal slots. AC. (-/) DC (-/) -PS Timer Cat. No. -N, Type Enclosure for Bulletin -P, -PH, -PK, -RTC Relays Approximate Shipping Weight:. kg (. lb) Bulletin -PS Timer Mounted on a -pole Bulletin Bulletin -P or -PK Relay or -pole Bulletin -PH Relay Approximate Shipping Weight: AC. kg (. lb) without -PS, edc. kg (. lb) without -PS. (.). (/) (-/). (/). (/). (.). (.). (.) (-/). (.). (.). (.). (.) Cat. No. -DR DIN Mounting Rail Series B Cat. No. -DR DIN Mounting Rail Series B Has No Mounting Holes DIN Rail Adapter -