HC RELAY PRODUCT TYPES
|
|
- Julie Horn
- 5 years ago
- Views:
Transcription
1 FROM SEQUENCE TO POWER CIRCUITS COMPATIBLE WORLDWIDE HC RELAY PRODUCT TYPES Standard type Amber sealed type FEATURES. Long track record means reliable quality.. Can provide switching across the range from low to high level power loads ( A to A). 3. Rich lineup includes relays with LED, with diode, and high-capacity types.. UL, CSA approval is standard Compliance also with Japanese Electrical Appliance and Material Control Law. TYPICAL APPLICATIONS Suitable for factory automation equipment and automotive devices. Control panels, power supply equipment, molding equipment, machine tools, welding equipment, agricultural equipment, etc.. Office equipment, automatic vending machines, telecommunications equipment, disaster prevention equipment, copiers, measuring devices, medical equipment, amusement devices, etc. 3. All types of household appliance Keep (Latching) relay With diode type TYPES HC Relay Type Standard type Amber sealed type HC relay HC keep (latching) relay DC type with surge absorbing diode AC type with surge absorbing CR circuit Contact arrangement Single side stable A: Available Notes:. HC relays with ground terminals also available.. HC relays with. mm wide PC board terminals also available. Contact arrangement Plug-in terminal type PC board terminal type Top mounting type Without LED With LED Without LED With LED (TM type) Form C A A A A A Form C A A A A A 3 Form C A A A A A Form C A A A A A Bifurcated (Twin) Form C A A A A A Form C A A A A A Single side stable Form C A A A A A Form C A A A A A Bifurcated (Twin) Form C A A A A A Single side stable Form C A (With operating indication) A (With operating indication) Form C A A Single side stable Form C A A 3 Form C A A Form C A A Bifurcated (Twin) Form C A A Form C A A Single side stable Form C A A 3 Form C A A Form C A A Bifurcated (Twin) Form C A A Remarks Amber sealed type also available 7 mm higher than standard type ds_c_en_hc: D
2 RELAY CONTACT ARRANGEMENT Type Single side stable contact -pole bifurcated (twin) contact Part number HC HCD Features Suitable for high-capacity load switching Standard type HC relays have high single-contact capacity; Form C: A Form C and 3 Form C: 7 A Form C: A LED INDICATION TYPE Type Part number With LED indication type HC -HL Bifurcated (twin) contact ensures high contact reliability Suitable for low level loads Minimum switching capability: A m V DC (reference value) 3 7 HC Features LED lights up when relay is operating Inspection and detection of trouble is easy. LEDs are green for DC types and red for AC types. All types are available with LED indication LED LED colors indicate the type of relay: red for AC type and green for DC type. Protection diode (Bottom view) HC RELAY SERIES PRODUCT TYPES Type Amber sealed type HC relay HC keep (Latching) relay HC relay with diode type (for DC) Part number HC E HCK HC - - V-D Features Relay is completely sealed with resin. Provides high reliability in adverse surroundings. Suitable for use in dusty conditions or where organic gases are present -pole bifurcated (twin) type available Relay with LED indication available Magnetic latching relay Suitable for nominal operating power saving of operating circuits and for memory circuits Has operating indication (mechanical indicator). Has built-in diode to absorb surge when the coil goes to the off state (for DC type). Suitable for protecting relay driver circuits and for noise suppression Diode characteristics: Reverse breakdown voltage, V, Forward current A Type HC relay with CR circuit (for AC) Part number HC - - V-R Features Has built-in CR circuit to absorb surge when the coil goes to the off state (for AC). Relay with CR circuit is 7 mm higher than standard type relay. ds_c_en_hc: D
3 VDE c, c, c MINIATURE RELAY FOR WIDER APPLICATIONS HC RELAYS Plug-in type TM type PC board type FEATURES. Long track record means reliable quality.. Can provide switching across the range from low to high level power loads ( A to A). 3. Full range of types Standard types include Form C, Form C, 3 Form C, Form C, -pole bifurcated (twin), plug-in type, PC board type, and TM type.. HC relay with LED indication type also available. UL, CSA approval is standard Compliance also with Japanese Electrical Appliance and Material Control Law. TYPICAL APPLICATIONS Suitable for factory automation equipment and automotive devices. Control panels, power supply equipment, molding equipment, machine tools, welding equipment, agricultural equipment, etc.. Office equipment, automatic vending machines, telecommunications equipment, disaster prevention equipment, copiers, measuring devices, medical equipment, amusement devices, etc. 3. All types of household appliance About Cd-free contacts We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix F should be added to the part number. The Suffix F is required only for Form C, Form C, 3 Form C contact type. The Form C and Form C bifurcated (twin) contact type is originally cadmium-free, the suffix F is not required.) Please replace parts containing Cadmium with Cadmium-free products and evaluate them with your actual application before use because the life of a relay depends on the contact material and load. ORDERING INFORMATION HC Contact arrangement : Form C : Form C 3: 3 Form C : Form C D: Bifurcated contact (twin) Terminal arrangement H: Plug-in type HL: Plug-in with LED indication HP: PC board type HPL: PC board with LED indication HTM: TM type AC,,,, (/), (/), (/), (/) V DC,,,, (/) V Contact material Contact material Ag alloy AgNi type Contact arrangement (cadmium-free) Form C F Form C F 3 Form C F Form C Nil Bifurcated contact (twin) Nil Notes: UL/CSA approved type is standard. Please inquire about VDE ( Form C, Form C, and Form C only) and TV-3 ( Form C and Form C only) approved products. 3 ds_c_en_hc: D
4 TYPES ) Plug-in type Form C Form C 3 Form C Form C Form C (twin) Part No. Part No. Part No. Part No. Part No. V AC HC-H-ACV-F HC-H-ACV-F HC3-H-ACV-F HC-H-ACV HCD-H-ACV V AC HC-H-ACV-F HC-H-ACV-F HC3-H-ACV-F HC-H-ACV HCD-H-ACV V AC HC-H-ACV-F HC-H-ACV-F HC3-H-ACV-F HC-H-ACV HCD-H-ACV V AC HC-H-ACV-F HC-H-ACV-F HC3-H-ACV-F HC-H-ACV HCD-H-ACV /V AC HC-H-ACV-F HC-H-ACV-F HC3-H-ACV-F HC-H-ACV HCD-H-ACV /V AC HC-H-ACV-F HC-H-ACV-F HC3-H-ACV-F HC-H-ACV HCD-H-ACV /V AC HC-H-ACV-F HC-H-ACV-F HC3-H-ACV-F HC-H-ACV HCD-H-ACV /V AC HC-H-ACV-F HC-H-ACV-F HC3-H-ACV-F HC-H-ACV HCD-H-ACV V DC HC-H-DCV-F HC-H-DCV-F HC3-H-DCV-F HC-H-DCV HCD-H-DCV V DC HC-H-DCV-F HC-H-DCV-F HC3-H-DCV-F HC-H-DCV HCD-H-DCV V DC HC-H-DCV-F HC-H-DCV-F HC3-H-DCV-F HC-H-DCV HCD-H-DCV V DC HC-H-DCV-F HC-H-DCV-F HC3-H-DCV-F HC-H-DCV HCD-H-DCV /V DC HC-H-DCV-F HC-H-DCV-F HC3-H-DCV-F HC-H-DCV HCD-H-DCV Standard packing: Carton: ; Case: HC ) Plug-in type (with LED indication) Form C Form C 3 Form C Form C Form C (twin) Part No. Part No. Part No. Part No. Part No. V AC HC-HL-ACV-F HC-HL-ACV-F HC3-HL-ACV-F HC-HL-ACV HCD-HL-ACV V AC HC-HL-ACV-F HC-HL-ACV-F HC3-HL-ACV-F HC-HL-ACV HCD-HL-ACV V AC HC-HL-ACV-F HC-HL-ACV-F HC3-HL-ACV-F HC-HL-ACV HCD-HL-ACV /V AC HC-HL-ACV-F HC-HL-ACV-F HC3-HL-ACV-F HC-HL-ACV HCD-HL-ACV /V AC HC-HL-ACV-F HC-HL-ACV-F HC3-HL-ACV-F HC-HL-ACV HCD-HL-ACV /V AC HC-HL-ACV-F HC-HL-ACV-F HC3-HL-ACV-F HC-HL-ACV HCD-HL-ACV /V AC HC-HL-ACV-F HC-HL-ACV-F HC3-HL-ACV-F HC-HL-ACV HCD-HL-ACV V DC HC-HL-DCV-F HC-HL-DCV-F HC3-HL-DCV-F HC-HL-DCV HCD-HL-DCV V DC HC-HL-DCV-F HC-HL-DCV-F HC3-HL-DCV-F HC-HL-DCV HCD-HL-DCV V DC HC-HL-DCV-F HC-HL-DCV-F HC3-HL-DCV-F HC-HL-DCV HCD-HL-DCV V DC HC-HL-DCV-F HC-HL-DCV-F HC3-HL-DCV-F HC-HL-DCV HCD-HL-DCV /V DC HC-HL-DCV-F HC-HL-DCV-F HC3-HL-DCV-F HC-HL-DCV HCD-HL-DCV Standard packing: Carton: ; Case: 3) PC board type Form C Form C 3 Form C Form C Form C (twin) Part No. Part No. Part No. Part No. Part No. V AC HC-HP-ACV-F HC-HP-ACV-F HC3-HP-ACV-F HC-HP-ACV HCD-HP-ACV V AC HC-HP-ACV-F HC-HP-ACV-F HC3-HP-ACV-F HC-HP-ACV HCD-HP-ACV V AC HC-HP-ACV-F HC-HP-ACV-F HC3-HP-ACV-F HC-HP-ACV HCD-HP-ACV V AC HC-HP-ACV-F HC-HP-ACV-F HC3-HP-ACV-F HC-HP-ACV HCD-HP-ACV /V AC HC-HP-ACV-F HC-HP-ACV-F HC3-HP-ACV-F HC-HP-ACV HCD-HP-ACV /V AC HC-HP-ACV-F HC-HP-ACV-F HC3-HP-ACV-F HC-HP-ACV HCD-HP-ACV /V AC HC-HP-ACV-F HC-HP-ACV-F HC3-HP-ACV-F HC-HP-ACV HCD-HP-ACV /V AC HC-HP-ACV-F HC-HP-ACV-F HC3-HP-ACV-F HC-HP-ACV HCD-HP-ACV V DC HC-HP-DCV-F HC-HP-DCV-F HC3-HP-DCV-F HC-HP-DCV HCD-HP-DCV V DC HC-HP-DCV-F HC-HP-DCV-F HC3-HP-DCV-F HC-HP-DCV HCD-HP-DCV V DC HC-HP-DCV-F HC-HP-DCV-F HC3-HP-DCV-F HC-HP-DCV HCD-HP-DCV V DC HC-HP-DCV-F HC-HP-DCV-F HC3-HP-DCV-F HC-HP-DCV HCD-HP-DCV /V DC HC-HP-DCV-F HC-HP-DCV-F HC3-HP-DCV-F HC-HP-DCV HCD-HP-DCV Standard packing: Carton: ; Case: Note: Please add -3 before -F in the part number when ordering the PC board type. mm width terminal (ex) HC-HP-ACV-3-F. ds_c_en_hc: D
5 ) PC board type (with LED indication) Form C Form C 3 Form C Form C Form C (twin) Part No. Part No. Part No. Part No. Part No. V AC HC-HPL-ACV-F HC-HPL-ACV-F HC3-HPL-ACV-F HC-HPL-ACV HCD-HPL-ACV V AC HC-HPL-ACV-F HC-HPL-ACV-F HC3-HPL-ACV-F HC-HPL-ACV HCD-HPL-ACV V AC HC-HPL-ACV-F HC-HPL-ACV-F HC3-HPL-ACV-F HC-HPL-ACV HCD-HPL-ACV /V AC HC-HPL-ACV-F HC-HPL-ACV-F HC3-HPL-ACV-F HC-HPL-ACV HCD-HPL-ACV /V AC HC-HPL-ACV-F HC-HPL-ACV-F HC3-HPL-ACV-F HC-HPL-ACV HCD-HPL-ACV /V AC HC-HPL-ACV-F HC-HPL-ACV-F HC3-HPL-ACV-F HC-HPL-ACV HCD-HPL-ACV V DC HC-HPL-DCV-F HC-HPL-DCV-F HC3-HPL-DCV-F HC-HPL-DCV HCD-HPL-DCV V DC HC-HPL-DCV-F HC-HPL-DCV-F HC3-HPL-DCV-F HC-HPL-DCV HCD-HPL-DCV V DC HC-HPL-DCV-F HC-HPL-DCV-F HC3-HPL-DCV-F HC-HPL-DCV HCD-HPL-DCV V DC HC-HPL-DCV-F HC-HPL-DCV-F HC3-HPL-DCV-F HC-HPL-DCV HCD-HPL-DCV /V DC HC-HPL-DCV-F HC-HPL-DCV-F HC3-HPL-DCV-F HC-HPL-DCV HCD-HPL-DCV Standard packing: Carton: ; Case: Note: Please add -3 before -F in the part number when ordering the PC board type. mm width terminal (ex) HC-HPL-ACV-3-F. ) TM type Form C Form C 3 Form C Form C Form C (twin) Part No. Part No. Part No. Part No. Part No. V AC HC-HTM-ACV-F HC-HTM-ACV-F HC3-HTM-ACV-F HC-HTM-ACV HCD-HTM-ACV V AC HC-HTM-ACV-F HC-HTM-ACV-F HC3-HTM-ACV-F HC-HTM-ACV HCD-HTM-ACV V AC HC-HTM-ACV-F HC-HTM-ACV-F HC3-HTM-ACV-F HC-HTM-ACV HCD-HTM-ACV V AC HC-HTM-ACV-F HC-HTM-ACV-F HC3-HTM-ACV-F HC-HTM-ACV HCD-HTM-ACV /V AC HC-HTM-ACV-F HC-HTM-ACV-F HC3-HTM-ACV-F HC-HTM-ACV HCD-HTM-ACV /V AC HC-HTM-ACV-F HC-HTM-ACV-F HC3-HTM-ACV-F HC-HTM-ACV HCD-HTM-ACV /V AC HC-HTM-ACV-F HC-HTM-ACV-F HC3-HTM-ACV-F HC-HTM-ACV HCD-HTM-ACV V DC HC-HTM-DCV-F HC-HTM-DCV-F HC3-HTM-DCV-F HC-HTM-DCV HCD-HTM-DCV V DC HC-HTM-DCV-F HC-HTM-DCV-F HC3-HTM-DCV-F HC-HTM-DCV HCD-HTM-DCV V DC HC-HTM-DCV-F HC-HTM-DCV-F HC3-HTM-DCV-F HC-HTM-DCV HCD-HTM-DCV V DC HC-HTM-DCV-F HC-HTM-DCV-F HC3-HTM-DCV-F HC-HTM-DCV HCD-HTM-DCV /V DC HC-HTM-DCV-F HC-HTM-DCV-F HC3-HTM-DCV-F HC-HTM-DCV HCD-HTM-DCV Standard packing: Carton: ; Case: RATING. Coil data ) AC coils (/Hz) Type Standard Nominal coil voltage V AC Pick-up voltage (at C F) Drop-out voltage (at C F) Nominal coil current [ %] (at C F) Hz Coil inductance Nominal operating power Max. allowable voltage (at 7 C F) /V AC./3.mA./.mA 7.H.7H.3VA.VA /V AC.7/7.mA /.ma.h.7h.3va.va Notes:. The relay operates in a range of % to % V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the rated voltage. In particular, for AC operation, if the applied voltage drops to % V or more below the rated voltage, humming will occur and a large current will flow leading possibly to coil burnout.. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation. (This value differs depending on the ambient temperature. Please contact us for details. Hz N.C. condition N.O. condition V AC ma ma.3h.h.3va.va V AC %V or more %V or less of ma ma.3h.h.3va.va of nominal V AC nominal voltage ma ma.7h.h.3va.va voltage /V AC (Initial) (Initial) 3./.7mA /3.mA 3.7H.3H.3VA.VA Hz Hz ma ma.7h.7h.3va.va %V of nominal voltage ) DC coils Type Standard Nominal coil voltage Pick-up voltage (at C F) Drop-out voltage (at C F) Nominal coil current [ %] (at C F) Coil resistance [ %] (at C F) Nominal operating power V DC ma.w V DC V DC V DC %V or less of nominal voltage (Initial) %V or more of nominal voltage (Initial) 7mA 37mA.mA,.W.W.W Max. allowable voltage (at 7 C F) %V of nominal voltage /V DC /ma,.w Notes:. The coil resistance for DC operation is the value measured when the coil temperature is C F. Compensate.% for every C change in temperature.. The relay operates in a range of % to % V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the rated voltage. 3. For use with V DC, connect a K (W) resistor, in series, to the V DC relay.. The maximum allowable impress voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation. (This value differs depending on the ambient temperature. Please contact us for details.) ds_c_en_hc: D
6 . Specifications Characteristics Item Specifications Contact Rating Electrical characteristics Mechanical characteristics Expected life Conditions Unit weight Arrangement Form C Form C 3 Form C Form C Form C (twin) Contact pressure Approx..N{gf} Approx..7N{gf} Approx..7N{gf} Approx..N{gf} Initial contact resistance, max Max. m (By voltage drop V DC A) Contact material Ag alloy (cd free) + Au flash AgNi type + Au clad Approx..7N{3gf} Nominal switching capacity (resistive load) A V AC 7A V AC 7A V AC A V AC 3A V AC Max. switching power (resistive load),va,7va,7va,va 7VA Max. switching voltage VAC Max. switching current A 7A 7A A 3A Nominal operating power AC (Hz):.3VA, AC (Hz):.VA, DC:. to.w Min. switching capacity (Reference value)* ma V DC A V DC Insulation resistance (Initial) Breakdown voltage (Initial) Between open contacts Between contact sets Between contact and coil Temperature rise (at 7 C F) Operate time (at C F)* Release time (at C F)* Shock resistance Vibration resistance Mechanical Functional Destructive Functional Destructive Electrical (resistive load) Conditions for operation, transport and storage* 3 Max. Operating speed Min.,M (at V DC) Measurement at same location as Initial breakdown voltage section. 7 Vrms for min. (Detection current: ma.) 7 Vrms for min. (Detection current: ma.), Vrms for min. (Detection current: ma.) Max. C (By resistive method, nominal voltage) Max. ms (Nominal voltage applied to the coil, excluding contact bounce time.) Max. ms (Nominal voltage applied to the coil, excluding contact bounce time.) (without diode) Min. m/s (Half-wave pulse of sine wave: ms; detection time: s.) Min. m/s (Half-wave pulse of sine wave: ms.) to Hz at double amplitude of mm (Detection time: s.) to Hz at double amplitude of mm Min. 7 : AC coil type (at cpm); Min. : DC coil type (at cpm) Min. (at cpm) Min. (at cpm) Min. (at cpm) Min. (at cpm) Min. (at cpm) Notes: In accordance with the Electrical Appliance and Material Safety Law, you cannot exceed a voltage of V AC when using the Form C type. For more information, please inquire. * This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. * For the AC coil types, the operate/release time will differ depending on the phase. *3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to. Usage, Storage and Transport Conditions in AMBIENT ENVIRONMENT section in Relay Technical Information. HC Ambient temperature: C to +7 C F to + F (without LED); C to + C F to + F (with LED) Humidity: to % R.H. (Not freezing and condensing at low temperature) cpm (at max. rating) Approx. g. oz 3. Switching capacity and expected life ) Electrical (at cpm) AC DC Load Resistive (cos = ) Inductive (cos.) Resistive Inductive Voltage V AC V AC V AC V AC V DC V DC Form C Form C 3 Form C Form C ) Mechanical (at cpm) Min. 7 (AC coil type); Min. (DC coil type) Expected life A A A 3A Min. 7A 7A 3A.A 3A A Min. A A A.A Min. 7A 7A 3.A A Min. A A.A.A 3A.A Min. 3A 3A.A A Min. 7A 7A Min. 3.A A Min. A A 3A.A Min. A A A A Min. 3A 3A A.A 3A.A Min. A A.A.A Min. Form C (twin) 3A 3A A.A 3A Min. ds_c_en_hc: D
7 REFERENCE DATA. Life curve Load: V AC resistive load.-() Switching capacity range (single contact type).-() Switching capacity range (-pole bifurcated (twin)) Life, times,, Mechanical life (DC type) Mechanical life (AC type) c ( V AC cosϕ = ) c 3c c Load current, A AC voltage, V ma ma HCc HCc, 3c A AC current HCc A A 7A AC voltage, V mv μa AC current A 3A A 3.-() Coil temperature rise ( Form C, AC type) Ambient temperature: C 77 F 7 3.-() Coil temperature rise ( Form C, AC type) Ambient temperature: C F 3.-(3) Coil temperature rise (3 Form C, AC type) Ambient temperature: C F (See note.) (See note.) (See note.) A 7A A A A Coil applied voltage, %V 3.-() Coil temperature rise ( Form C, AC type) Ambient temperature: to C to 7 F (See note.) 3.-(7) Coil temperature rise (3 Form C, DC type) Ambient temperature: C F 7 Coil applied voltage, %V 7A A A Coil applied voltage, %V A 3A A 7 7 ds_c_en_hc: D A A A Coil applied voltage, %V 3.-() Coil temperature rise ( Form C, DC type) Ambient temperature: C F 7 A A A Coil applied voltage, %V 3.-() Coil temperature rise ( Form C, DC type) Ambient temperature: 7 to C to F 7 A 3A A Coil applied voltage, %V 7 3.-() Coil temperature rise ( Form C, DC type) Ambient temperature: C F 7 7A A A Coil applied voltage, %V 7A A A Coil applied voltage, %V When the nominal voltage is applied to AC or V coil types respectively, the figures of coil temperature rise increase by approx. degrees to the ones shown on each graph.
8 DIMENSIONS(mm inch). Plug-in type CAD Data Interested in CAD data? You can obtain CAD data for all products with a from your local Panasonic Electric Works representative. Form C type CAD Data Schematic (Bottom view) Standard type 7 mark LED AC type 7 LED DC type ( ) ( ) 3 ( ) (+) General tolerance:.3. CAD Data Form C type Schematic (Bottom view) Standard type ( ) LED AC type ( ) 3 ( ) LED DC type (+) General tolerance:.3. CAD Data 3 Form C type Schematic (Bottom view) Standard type ( ) 7 LED AC type 3 ( ) 7 3 ( ) LED DC type 3 (+) General tolerance:.3. ds_c_en_hc: D
9 CAD Data Form C and -pole bifurcated (twin) types Standard type LED AC type 3 7 LED DC type ( ) ( ) 3 ( ) (+) General tolerance:.3. Schematic (Bottom view). PC board type CAD Data Form C type The diagrams show the external dimensions of the Form C and -pole bifurcated (twin) types. For Form C, Form C, and 3 Form C, see diagrams at plug-in types (only the terminals are different). Types with. mm terminal width are also available. General tolerance:.3. PC board pattern..7 Form C Form C 3 Form C Form C dia. hole -.7 dia dia. hole -.7 dia dia. hole -.7 dia dia. hole -.7 dia. Schematic Same schematic as plug-in type HC relay Tolerance:.. ds_c_en_hc: D
10 3. TM type CAD Data Form C type HC The diagrams show the external dimensions of the Form C and -pole bifurcated (twin) types. For Form C, Form C, and 3 Form C, see diagrams at plug-in types (only the terminals are different) General tolerance:.3. Chassis (Panel) cutout -3. dia. -. dia Tolerance:.. Schematic Same schematic as plug-in type HC relay Be aware that there is no LED indicator with CR circuit and built-in diode types. Chassis (Panel) cutout in tandem mounting 37.. Notes:. In mounting, use M3 screws and M3 washers.. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover. 3. When tightening fixing screws, the optimum torque range should be. to. N m, (3 to kgf cm). Moreover, use washers to prevent loosening For Cautions for Use, see Relay Technical Information. ds_c_en_hc: D
11 SEALED CONSTRUCTION High reliability ensured in challenging environments. HC RELAYS AMBER SEALED TYPE Plug-in type PC board type TM type FEATURES. Even when left for long periods in challenging environments, resistance values for the contacts remain stable.. Compact yet compatible all over the world. 3. Can be used in a wide variety of applications.. With LED indication type also available. and mounting dimensions same as for HC relays Connection accessories (terminal sockets and sockets) also shared.. UL, CSA approval is standard Compliance also with Japanese Electrical Appliance and Material Control Law. TYPICAL APPLICATIONS. Where surrounding atmosphere is bad Cotton mills, flour mills, chemical works, traffic signals, etc.. In situations where high reliability is required Safety equipment, alarms, copiers, telecommunications devices, computers, etc. About Cd-free contacts We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix F should be added to the part number. The Suffix F is required only for Form C, Form C contact type. The Form C and Form C bifurcated (twin) contact type is originally cadmium-free, the suffix F is not required.) Please replace parts containing Cadmium with Cadmium-free products and evaluate them with your actual application before use because the life of a relay depends on the contact material and load. ORDERING INFORMATION HC Contact arrangement : Form C : Form C : Form C E: Amber sealed type ED: Amber sealed type bifurcated contact (twin) (Only Form C) Terminal arrangement H: L: HP: PL: Plug-in type Plug-in with LED indication PC board type PC board with LED indication HTM: TM type AC,,,, (/), (/), (/), (/) V DC,,,, (/) V Contact material Contact material Contact arrangement AgSnO type AgNi type Form C Form C F F Form C -pole bifurcated (twin) Nil Nil Note: UL/CSA approved type is standard. ds_c_en_hc: D
12 TYPES ) Plug-in type Form C Form C Form C Form C (twin) Part No. Part No. Part No. Part No. V AC HCE-H-ACV-F HCE-H-ACV-F HCE-H-ACV HCED-H-ACV V AC HCE-H-ACV-F HCE-H-ACV-F HCE-H-ACV HCED-H-ACV V AC HCE-H-ACV-F HCE-H-ACV-F HCE-H-ACV HCED-H-ACV V AC HCE-H-ACV-F HCE-H-ACV-F HCE-H-ACV HCED-H-ACV /V AC HCE-H-ACV-F HCE-H-ACV-F HCE-H-ACV HCED-H-ACV /V AC HCE-H-ACV-F HCE-H-ACV-F HCE-H-ACV HCED-H-ACV /V AC HCE-H-ACV-F HCE-H-ACV-F HCE-H-ACV HCED-H-ACV /V AC HCE-H-ACV-F HCE-H-ACV-F HCE-H-ACV HCED-H-ACV V DC HCE-H-DCV-F HCE-H-DCV-F HCE-H-DCV HCED-H-DCV V DC HCE-H-DCV-F HCE-H-DCV-F HCE-H-DCV HCED-H-DCV V DC HCE-H-DCV-F HCE-H-DCV-F HCE-H-DCV HCED-H-DCV V DC HCE-H-DCV-F HCE-H-DCV-F HCE-H-DCV HCED-H-DCV /V DC HCE-H-DCV-F HCE-H-DCV-F HCE-H-DCV HCED-H-DCV Standard packing: Carton: ; Case: HC ) Plug-in type (With LED indication) Form C Form C Form C Form C (twin) Part No. Part No. Part No. Part No. V AC HCE-L-ACV-F HCE-L-ACV-F HCE-L-ACV HCED-L-ACV V AC HCE-L-ACV-F HCE-L-ACV-F HCE-L-ACV HCED-L-ACV V AC HCE-L-ACV-F HCE-L-ACV-F HCE-L-ACV HCED-L-ACV V AC HCE-L-ACV-F HCE-L-ACV-F HCE-L-ACV HCED-L-ACV /V AC HCE-L-ACV-F HCE-L-ACV-F HCE-L-ACV HCED-L-ACV /V AC HCE-L-ACV-F HCE-L-ACV-F HCE-L-ACV HCED-L-ACV /V AC HCE-L-ACV-F HCE-L-ACV-F HCE-L-ACV HCED-L-ACV /V AC HCE-L-ACV-F HCE-L-ACV-F HCE-L-ACV HCED-L-ACV V DC HCE-L-DCV-F HCE-L-DCV-F HCE-L-DCV HCED-L-DCV V DC HCE-L-DCV-F HCE-L-DCV-F HCE-L-DCV HCED-L-DCV V DC HCE-L-DCV-F HCE-L-DCV-F HCE-L-DCV HCED-L-DCV V DC HCE-L-DCV-F HCE-L-DCV-F HCE-L-DCV HCED-L-DCV /V DC HCE-L-DCV-F HCE-L-DCV-F HCE-L-DCV HCED-L-DCV Standard packing: Carton: ; Case: 3) PC board type Form C Form C Form C Form C (twin) Part No. Part No. Part No. Part No. V AC HCE-HP-ACV-F HCE-HP-ACV-F HCE-HP-ACV HCED-HP-ACV V AC HCE-HP-ACV-F HCE-HP-ACV-F HCE-HP-ACV HCED-HP-ACV V AC HCE-HP-ACV-F HCE-HP-ACV-F HCE-HP-ACV HCED-HP-ACV V AC HCE-HP-ACV-F HCE-HP-ACV-F HCE-HP-ACV HCED-HP-ACV /V AC HCE-HP-ACV-F HCE-HP-ACV-F HCE-HP-ACV HCED-HP-ACV /V AC HCE-HP-ACV-F HCE-HP-ACV-F HCE-HP-ACV HCED-HP-ACV /V AC HCE-HP-ACV-F HCE-HP-ACV-F HCE-HP-ACV HCED-HP-ACV /V AC HCE-HP-ACV-F HCE-HP-ACV-F HCE-HP-ACV HCED-HP-ACV V DC HCE-HP-DCV-F HCE-HP-DCV-F HCE-HP-DCV HCED-HP-DCV V DC HCE-HP-DCV-F HCE-HP-DCV-F HCE-HP-DCV HCED-HP-DCV V DC HCE-HP-DCV-F HCE-HP-DCV-F HCE-HP-DCV HCED-HP-DCV V DC HCE-HP-DCV-F HCE-HP-DCV-F HCE-HP-DCV HCED-HP-DCV /V DC HCE-HP-DCV-F HCE-HP-DCV-F HCE-HP-DCV HCED-HP-DCV Standard packing: Carton: ; Case: Note: The PC board. mm width terminal type is also available, please part number. suffix 3 is needed when ordering ( Form C, Form C (twin) only) ds_c_en_hc: D
13 ) PC board type (With LED indication) Form C Form C Form C Form C (twin) Part No. Part No. Part No. Part No. V AC HCE-PL-ACV-F HCE-PL-ACV-F HCE-PL-ACV HCED-PL-ACV V AC HCE-PL-ACV-F HCE-PL-ACV-F HCE-PL-ACV HCED-PL-ACV V AC HCE-PL-ACV-F HCE-PL-ACV-F HCE-PL-ACV HCED-PL-ACV V AC HCE-PL-ACV-F HCE-PL-ACV-F HCE-PL-ACV HCED-PL-ACV /V AC HCE-PL-ACV-F HCE-PL-ACV-F HCE-PL-ACV HCED-PL-ACV /V AC HCE-PL-ACV-F HCE-PL-ACV-F HCE-PL-ACV HCED-PL-ACV /V AC HCE-PL-ACV-F HCE-PL-ACV-F HCE-PL-ACV HCED-PL-ACV /V AC HCE-PL-ACV-F HCE-PL-ACV-F HCE-PL-ACV HCED-PL-ACV V DC HCE-PL-DCV-F HCE-PL-DCV-F HCE-PL-DCV HCED-PL-DCV V DC HCE-PL-DCV-F HCE-PL-DCV-F HCE-PL-DCV HCED-PL-DCV V DC HCE-PL-DCV-F HCE-PL-DCV-F HCE-PL-DCV HCED-PL-DCV V DC HCE-PL-DCV-F HCE-PL-DCV-F HCE-PL-DCV HCED-PL-DCV /V DC HCE-PL-DCV-F HCE-PL-DCV-F HCE-PL-DCV HCED-PL-DCV Standard packing: Carton: ; Case: Note: The PC board. mm width terminal type is also available, please part number. suffix 3 is needed when ordering ( Form C, Form C (twin) only) ) TM type Form C Form C Form C Form C (twin) Part No. Part No. Part No. Part No. V AC HCE-HTM-ACV-F HCE-HTM-ACV-F HCE-HTM-ACV HCED-HTM-ACV V AC HCE-HTM-ACV-F HCE-HTM-ACV-F HCE-HTM-ACV HCED-HTM-ACV V AC HCE-HTM-ACV-F HCE-HTM-ACV-F HCE-HTM-ACV HCED-HTM-ACV V AC HCE-HTM-ACV-F HCE-HTM-ACV-F HCE-HTM-ACV HCED-HTM-ACV /V AC HCE-HTM-ACV-F HCE-HTM-ACV-F HCE-HTM-ACV HCED-HTM-ACV /V AC HCE-HTM-ACV-F HCE-HTM-ACV-F HCE-HTM-ACV HCED-HTM-ACV /V AC HCE-HTM-ACV-F HCE-HTM-ACV-F HCE-HTM-ACV HCED-HTM-ACV /V AC HCE-HTM-ACV-F HCE-HTM-ACV-F HCE-HTM-ACV HCED-HTM-ACV V DC HCE-HTM-DCV-F HCE-HTM-DCV-F HCE-HTM-DCV HCED-HTM-DCV V DC HCE-HTM-DCV-F HCE-HTM-DCV-F HCE-HTM-DCV HCED-HTM-DCV V DC HCE-HTM-DCV-F HCE-HTM-DCV-F HCE-HTM-DCV HCED-HTM-DCV V DC HCE-HTM-DCV-F HCE-HTM-DCV-F HCE-HTM-DCV HCED-HTM-DCV /V DC HCE-HTM-DCV-F HCE-HTM-DCV-F HCE-HTM-DCV HCED-HTM-DCV Standard packing: Carton: ; Case: RATING. Coil data (Common for standard types). Specifications Characteristics Item Specifications Form C Form C Form C Form C (twin) Contact Arrangement Form C Form C Form C Form C Nominal switching capacity (resistive load) A V AC 3A V AC A V AC A V AC Max. switching power (resistive load),va 7VA VA VA Rating Max. switching voltage VAC VAC VAC VAC Max. switching current A 3A A A Min. switching capacity (Reference value)* ma mv DC A mv DC Electrical characteristics Temperature rise (at C F) Max. C (By resistive method, nominal voltage) Expected life Electrical Min. resistive load (at cpm) Conditions Conditions for operation, transport and storage* Ambient air pressure 7mmHg % (,3mb %) Notes:Other specifications are same as standard types. *This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. *The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value.refer to. Usage, Storage and Transport Conditions in AMBIENT ENVIRONMENT section in Relay Technical Information.. 3. Switching capacity and expected life ) Electrical (at cpm) ) Mechanical (at cpm) Min. 7 (AC coil type); Min. (DC coil type) Ambient temperature: C to + C F to + F; Humidity: to % R.H. (Not freezing and condensing at low temperature) Load AC DC Resistive (cos = ) Inductive (cos.) Resistive Inductive Expected life Voltage V AC V AC V AC V AC V DC V DC HCE A A 3A A Min. HCE 3A 3A A.7A Min. HCE A A A.A Min. HCED ( Form C twin) A A Min. 3 ds_c_en_hc: D
14 REFERENCE DATA.-() Switching capacity range (single contact type) AC voltage, V V V V ma HCE HCE HCE A A3A A A AC current.-() Coil temperature rise ( Form C AC type) Ambient temperature: C F 7 Voltage applied to coil, %V.-() Coil temperature rise ( Form C DC type) Ambient temperature: C F 7 3A Voltage applied to coil, %V DIMENSIONS HC relays are unified to standard sizes. Please refer to standard type information. A.-() Switching capacity range (-pole bifurcated (twin)) AC voltage, V mv μa AC current A 3A A.-(3) Coil temperature rise ( Form C AC type) Ambient temperature: C F 7 A Voltage applied to coil, %V Note: Coil temperature rise When the nominal voltage is applied to AC or V coil types respectively, the figures of coil temperature rise increase by approx. degrees to the ones shown on each graph. NOTES When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover. When tightening fixing screws, the optimum torque range should be. to. N m, (3 to kgf cm). If screws are over tightened, the cover may distort, resulting in poor sealing. Moreover, to prevent loosening, use washers. HC.-() Coil temperature rise ( Form C AC type) Ambient temperature: C F 7 A Voltage applied to coil, %V.-() Coil temperature rise ( Form C DC type) Ambient temperature: C F 7 A A Voltage applied to coil, %V For Cautions for Use, see Relay Technical Information. ds_c_en_hc: D
15 MAGNETIC MEMORY TYPE HC RELAY HC LATCHING (KEEP) RELAYS FEATURES. Energy-saving type. Wide range of applications in control circuits for industrial equipment and consumer devices. 3. Form factors same as for HC relays. With operation indicator. Can be used in a wide variety of applications. About Cd-free contacts We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix F should be added to the part number.) Please replace parts containing Cadmium with Cadmium-free products and evaluate them with your actual application before use because the life of a relay depends on the contact material and load. TYPES Plug-in type Part No. HCK-ACV-F HCK-ACV-F HCK-ACV-F HCK-ACV-F HCK-ACV-F HCK-DCV-F HCK-DCV-F HCK-DCV-F HCK-DCV-F HCK-DCV-F PC board type Part No. HCK-P-ACV-F HCK-P-ACV-F HCK-P-ACV-F HCK-P-ACV-F HCK-P-ACV-F HCK-P-DCV-F HCK-P-DCV-F HCK-P-DCV-F HCK-P-DCV-F HCK-P-DCV-F Standard packing: Carton: ; Case: Notes:. Some materials and price vary. Please inquire for details.. Please refer to the standards chart for information on compliance with international standards. RATING. Coil data ) AC coils (/Hz) Contact arrangement Form C Nominal coil voltage Set voltage (at C F) Reset voltage (at C F) Nominal operating current [ %] (at C F) Reset Set coil coil N.C. codition Set coil Coil inductance N.O. condition N.C. codition Reset coil N.O. condition Nominal operating power Set coil V AC ma 3mA.3VA.VA V AC V AC V AC %V or less of nominal voltage (Initial) %V or less of nominal voltage (Initial) ma ma.ma ma.ma.ma.va.va.va.va.va.va V AC 3.3mA 7.mA.33VA.7VA Reset coil Max. allowable voltage (at C F) %V of nominal voltage ds_c_en_hc: D
16 ) DC coils Contact arrangement Form C Nominal coil voltage Set voltage (at C F) Reset voltage (at C F) Nominal operating current [ %] (at C F) Coil resistance [ %] (at C F) Nominal operating power Set coil Reset coil Set coil Reset coil Set coil Reset coil V DC 7mA 7mA.W.W V DC %V or less of %V or less of ma.ma.w.3w V DC nominal voltage nominal voltage.ma.ma 7.3W.W V DC (Initial) (Initial).3mA 3.7mA,7 3,.W.W V DC.mA.mA, 7,.W.W Notes:. The allowable coil resistance range is % when within, and % when., or higher.. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation. (This value differs depending on the ambient temperature. Please contact us for details.) HC Max. allowable voltage (at C F) %V of nominal voltage. Specifications Characteristics Item Specifications Contact Contact pressure Approx..N{gf} Initial contact resistance, max Max. m (By voltage drop V DC A) Nominal switching capacity (resistive load) 3A V AC Max. switching power (resistive load) 7VA Rating Max. switching current 3A Nominal operating power Set coil:.va to.33va; Reset coil:.va to.va Min. switching capacity (Reference value)* A mv DC Electrical characteristics Breakdown voltage (Initial) Between contact and coil, Vrms for min. (initial) Temperature rise Set coil: Max. C; Reset coil: Max. C (at nominal voltage) Set time/reset time (at C F) Approx. ms/ms (at nominal voltage) Mechanical Shock resistance Functional Min. m/s characteristics (Half-wave pulse of sine wave: ms; detection time: s.) Mechanical Min. Expected life 7 (at cpm) Electrical Min. rated load (at cpm) Conditions Ambient temperature C to + C F to + F (Not freezing and condensing at low temperature) Notes:*This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load..other specifications are same as standard types. REFERENCE DATA Coil temperature rise Tested sample: HCK-DCV, pcs Ambient temperature: C. F 7 3A A Coil applied voltage, %V ds_c_en_hc: D
17 DIMENSIONS(mm inch) Plug-in type ( Form C) CAD Data Interested in CAD data? You can obtain CAD data for all products with a from your local Panasonic Electric Works representative CAD Data mark Schematic (Bottom view) DC type AC type + 3 Reset + Set 3 Reset Set General tolerance:.3. PC board type ( Form C) CAD Data MOUNTING METHOD The mounting method and mounting holes can all be made the same as for the Form C HC relay terminal socket General tolerance:.3. NOTES. The schematic differs from that in the standard type Form C HC relay. Follow the schematic on the cover sticker.. Conform with the schematic for the DC type, which has a polarized coil. 3. Because retention characteristics vary according to the waveform of the voltage applied to the coil, do your best to avoid capacitor driving. In capacitor driving, use a capacitor of F or more. Schematic (Bottom view) DC type AC type + 3 Reset + Set 3 Reset Set PC board pattern (Bottom view) - dia. hole -.7 dia. hole Idle terminal (hole needed) Tolerance:... Ensure that the minimum pulse width of voltage applied to coil is greater than ms. For Cautions for Use, see Relay Technical Information. 7 ds_c_en_hc: D
18 Has built-in diode to absorb surge For use in semiconductor circuits HC RELAY WITH DIODE HC FEATURES. The built-in diode absorbs surge voltage arising when the coil goes to the off state (for DC type). Diode characteristics; Reverse breakdown voltage:,v, Forward current: A. With LED indicator type also available 3. UL, CSA approval is standard Compliance also with Japanese Electrical Appliance and Material Control Law. TYPICAL APPLICATIONS Suitable for factory automation equipment and automotive devices. Control panels, power supply equipment, molding equipment, machine tools, welding equipment, agricultural equipment, etc.. Office equipment, automatic vending machines, telecommunications equipment, disaster prevention equipment, copiers, measuring devices, medical equipment, amusement devices, etc. 3. All types of household appliance About Cd-free contacts We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix F should be added to the part number. The Suffix F is required only for Form C, Form C, 3 Form C contact type. The Form C and Form C bifurcated (twin) contact type is originally cadmium-free, the suffix F is not required.) Please replace parts containing Cadmium with Cadmium-free products and evaluate them with your actual application before use because the life of a relay depends on the contact material and load. TYPES ) Plug-in type Form C Form C 3 Form C Form C Form C (twin) Part No. Part No. Part No. Part No. Part No. V DC HC-DCV-D-F HC-DCV-D-F HC3-DCV-D-F HC-DCV-D HCD-DCV-D V DC HC-DCV-D-F HC-DCV-D-F HC3-DCV-D-F HC-DCV-D HCD-DCV-D V DC HC-DCV-D-F HC-DCV-D-F HC3-DCV-D-F HC-DCV-D HCD-DCV-D V DC HC-DCV-D-F HC-DCV-D-F HC3-DCV-D-F HC-DCV-D HCD-DCV-D /V DC HC-DCV-D-F HC-DCV-D-F HC3-DCV-D-F HC-DCV-D HCD-DCV-D Standard packing: Carton: ; Case: ) Plug-in type (with LED indication) Form C Form C 3 Form C Form C Form C (twin) Part No. Part No. Part No. Part No. Part No. V DC HC-L-DCV-D-F HC-L-DCV-D-F HC3-L-DCV-D-F HC-L-DCV-D HCD-L-DCV-D V DC HC-L-DCV-D-F HC-L-DCV-D-F HC3-L-DCV-D-F HC-L-DCV-D HCD-L-DCV-D V DC HC-L-DCV-D-F HC-L-DCV-D-F HC3-L-DCV-D-F HC-L-DCV-D HCD-L-DCV-D V DC HC-L-DCV-D-F HC-L-DCV-D-F HC3-L-DCV-D-F HC-L-DCV-D HCD-L-DCV-D /V DC HC-L-DCV-D-F HC-L-DCV-D-F HC3-L-DCV-D-F HC-L-DCV-D HCD-L-DCV-D Standard packing: Carton: ; Case: ds_c_en_hc: D
19 RATING. Coil data (Common for standard DC coil types). Specifications Characteristics Item Specifications Ambient temperature: C to + C F to + F Conditions Conditions for operation, transport and storage* Humidity: to % R.H. (Not freezing and condensing at low temperature) Notes: Other specifications are same as standard types. *The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to. Usage, Storage and Transport Conditions in AMBIENT ENVIRONMENT section in Relay Technical Information. REFERENCE DATA.-() DC coil surge voltage waveform (without diode).-() DC coil surge voltage waveform (with diode) Diode characteristics; Reverse breakdown voltage:,v, Forward current: A ON OFF ON OFF V + DCV - To digital memory ( + DCV - To digital memory Reverse breakdown voltage:, V Forward current: A ( DIMENSIONS Same dimensions as HC relay standard/ plug-in type Schematic Without LED indicator With LED indicator Protection (surge-absorbing) diode LED Protection (surge-absorbing) diode NOTES. Pay attention to the polarity.. Diode characteristics Reverse breakdown voltage:,v Forward current: A For Cautions for Use, see Relay Technical Information. ds_c_en_hc: D
20 Able to absorb surge voltage in AC specification CR circuit is built-in HC RELAYS WITH CR HC FEATURES. With CR circuits built in, surge voltage arising in the AC type when the coil goes to the off state is absorbed.. HC relay with LED indication type also available 3. UL, CSA approval is standard Compliance also with Japanese Electrical Appliance and Material Control Law. TYPICAL APPLICATIONS Suitable for factory automation equipment and automotive devices. Control panels, power supply equipment, molding equipment, machine tools, welding equipment, agricultural equipment, etc.. Office equipment, automatic vending machines, telecommunications equipment, disaster prevention equipment, copiers, measuring devices, medical equipment, amusement devices, etc. About Cd-free contacts We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix F should be added to the part number. The Suffix F is required only for Form C, Form C, 3 Form C contact type. The Form C and Form C bifurcated (twin) contact type is originally cadmium-free, the suffix F is not required.) Please replace parts containing Cadmium with Cadmium-free products and evaluate them with your actual application before use because the life of a relay depends on the contact material and load. TYPES ) Plug-in type Form C Form C 3 Form C Form C Form C (twin) Part No. Part No. Part No. Part No. Part No. /V AC HC-ACV-R-F HC-ACV-R-F HC3-ACV-R-F HC-ACV-R HCD-ACV-R /V AC HC-ACV-R-F HC-ACV-R-F HC3-ACV-R-F HC-ACV-R HCD-ACV-R /V AC HC-ACV-R-F HC-ACV-R-F HC3-ACV-R-F HC-ACV-R HCD-ACV-R /V AC HC-ACV-R-F HC-ACV-R-F HC3-ACV-R-F HC-ACV-R HCD-ACV-R Standard packing: Carton: ; Case: ) Plug-in type (with LED indication) Form C Form C 3 Form C Form C Form C (twin) Part No. Part No. Part No. Part No. Part No. /V AC HC-L-ACV-R-F HC-L-ACV-R-F HC3-L-ACV-R-F HC-L-ACV-R HCD-L-ACV-R /V AC HC-L-ACV-R-F HC-L-ACV-R-F HC3-L-ACV-R-F HC-L-ACV-R HCD-L-ACV-R /V AC HC-L-ACV-R-F HC-L-ACV-R-F HC3-L-ACV-R-F HC-L-ACV-R HCD-L-ACV-R /V AC HC-L-ACV-R-F HC-L-ACV-R-F HC3-L-ACV-R-F HC-L-ACV-R HCD-L-ACV-R Standard packing: Carton: ; Case: RATING. Coil data (Common for standard AC coil types). Specifications Characteristics Item Specifications Electrical characteristics Temperature rise Max. C (By resistive method, nominal voltage, rated current at C) Conditions Conditions for operation, transport and storage* Ambient temperature: C to + C F to + F Humidity: to % R.H. (Not freezing and condensing at low temperature) Notes: Other specifications are same as standard types. *The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to. Usage, Storage and Transport Conditions in AMBIENT ENVIRONMENT section in Relay Technical Information. ds_c_en_hc: D
21 REFERENCE DATA.-() AC coil surge voltage waveform (with CR circuit) Tested sample: HC-ACV-R.-() AC coil surge voltage waveform (without CR circuit) Tested sample: HC-ACV V V.ms V 3.ms.ms V ACV To digital memory ACV To digital memory DIMENSIONS (Unit: mm inch) Plug-in type Form C dimensions and schematic of the Form C and -pole bifurcated (twin) types. For the Form C, Form C, and 3 Form C types, only the terminals differ. The dimensions of the terminal are the same as for standard type HC relays General tolerance:.3. Schematic Without LED indicator With LED indicator Diagrams show the external Connection accessories Connection accessories (terminal sockets and sockets) are the same as for standard type HC relays. To hold the relay in place, use the hold-down clip that is provided. For Cautions for Use, see Relay Technical Information. ds_c_en_hc: D
22 ACCESSORIES (Sockets and Terminal sockets) HC RELAY ACCESSORIES HC HC RELAY SOCKETS. Plug-in type sockets, PC board type sockets, and wrapping type sockets are available for HC relays.. In the table below, the socket suitable for each type of HC relay is indicated by a black dot. 3. UL/CSA approval is standard.. A hold-down clip is included in the package. The fixing method is the same as for HC sockets, ordinary HC terminal sockets and HL sockets. HC/HL-LEAF-SPRING-MK SOCKET SELECTOR CHART Type No. of pole Item Part No. Applicable HC relay (Plug-in type) Standard/Bifurcated contact (DC) Amber Form C Form C 3 Form C Form C Form C (twin) Form C Form C Form C Form C (twin) Keep relay Form C Plug-in PC board Wrapping -pole HC-socket HC-SS-K //-pole (common) -pole -pole 3-pole //-pole (common) //-pole (common) HC-socket HC-SS-K HC-socket for PC board HC-socket for PC board HC3-socket for PC board HC-socket for PC board Notes:. Use the retainer that is shipped with the terminal socket.. UL/CSA approved type is standard (except for wrapping socket). HC-PS-K HC-PS-K HC3-PS-K HC-PS-K HC-wrapping socket HC-WS-K HC RELAY TERMINAL SOCKETS. Ordinary terminal sockets and terminal sockets for DIN rail assembly are available.. In the table below, the terminal socket suitable for each type of HC relay is indicated by a black dot. 3. UL/CSA approval is standard.. A hold-down clip is included in the package. Ordinary terminal socket The fixing method is the same as for sockets. HC/HL-LEAF-SPRING-MK Terminal sockets for DIN rail assembly The fixing method is the same as for the HC DIN rail terminal sockets and the HL DIN terminal sockets. HC/HL-LEAF-SPRING-K ds_c_en_hc: D
23 TERMINAL SOCKET SELECTOR CHART Type For DIN rail For general No. of pole Item Part No. -pole HC-slim type DIN terminal socket HC-SFD-S -pole HC-DIN HC-SFD-K 3-pole HC3-DIN HC3-SFD-K //-pole (common) -pole 3-pole //-pole (common) HC-DIN high terminal socket HC-terminal socket HC3-high terminal socket HC-high terminal socket HC-SFD-K HC-SF-K HC3-HSF-K HC-HSF-K Packing quantity Applicable HC relay (Plug-in type) Standard/Bifurcated contact (DC) Amber Carton Case Form C Form C 3 Form C Form C Form C (twin) Form C Form C Form C Form C (twin) Notes:. Use the retainer that is shipped with the terminal socket.. UL/CSA approved type is standard (except for HC-TSF-K). 3. In order to prevent breakage and disfiguring, the screw tightening torque for the terminal socket should be within the range of. to. N m { to 7kgf cm}. Keep relay Form C DIMENSIONS (Unit: mm inch). Plug-in type sockets HC-Socket (HC-SS-K) HC-Socket (HC-SS-K) General tolerance: General tolerance: Mounting hole diagram Side-by-side installation With a relay mounted (HC-SS-K) General tolerance:.. Notes:. Applicable chassis board thickness is. to. mm.. Installation is easy by inserting the socket from the top into the holes and by depressing the two down arrows on the retention fitting from the front. Hold-down clip is packaged with the socket. 3 ds_c_en_hc: D
24 . PC board type sockets HC- PC board type socket (HC-PS-K) HC- PC board type socket (HC-PS-K) HC General tolerance: General tolerance:.3. HC3- PC board type socket (HC3-PS-K) HC- PC board type socket (HC-PS-K) General tolerance:.3. PC board pattern (Bottom view) With a relay mounted General tolerance: Side-by-side installation Hold-down clip is packaged with the socket. Form C Form C 3 Form C Form C dia. ho.7 dia dia. hole dia.. - dia. hole -.7 dia. - dia. hole dia dia. hole -.7 dia. General tolerance:.. ds_c_en_hc: D
25 3. Wrapping type sockets Standard wrapping type sockets (HC-WS-K) ±..3±. Hold-down clip (Hold-down clip is packaged with the socket) Terminal cross section ±..3±..±..3±...3 ±..3±. General tolerance:.3. Note: The external and mounting dimensions are the same for -pole (HC-WS-K), -pole (HC-WS-K), and 3-pole (HC3-WS-K) types. Only the number of terminals varies. Mounting hole diagram Side-by-side installation General tolerance:.. Notes:. Applicable chassis board thickness is. to. mm.. Installation is easy by inserting the socket from the top into the holes and by depressing the two down arrows on the retention fitting from the front.. Terminal sockets for DIN rail assembly HC-Slim type terminal sockets for DIN rail assembly (HC-SFD-S) ±..±. 3.3±..±. M3 screw M. screw ±..77±. Schematic N.C. N.O..±..±..3±..±..±..±. ±..7±. 7±.±.3 ±..3±..±.3.±. 7±.3±.3 3.±..3±. COM.3.±.3 ±.±. ± ±.3.3±. 3 General tolerance:.. Coil ds_c_en_hc: D
26 HC-high terminal socket for DIN rail assembly (HC-SFD-K) Schematic 3.3±..±. ±..±. M3 screw M. screw.±..3±. N.C. N.O..±..±..3±..±..±..±. ±..7±..±.3.±. 7±.3±.3 COM.3 ±..±. 3 General tolerance:.. Coil HC3-high terminal socket for DIN rail assembly (HC3-SFD-K) ±..±. M3 screw M. screw.±..3±. Schematic 3 N.C. N.O..±..±..3±. ±..3±. ±..7±..±..±.3.±. 7±.3±.3 7 COM.. ±..±. Coil 3 General tolerance:.. HC-high terminal socket for DIN rail assembly (HC-SFD-K).±..7±. ±..±. 3.3±..±. M3 screw M. screw.±..3±. Schematic 3 N.C. 7 N.O..±..±..3±..±..±..±. ±..7±..±.3.±. 7±.3±.3 3 COM Coil.3 ±..±. General tolerance:.. Mounting hole diagram HC-Slim type HC, HC3 and HC HC vertical type With a relay mounted (HC-SFD-K).3 ±. ±..±..± M3. screw hole.3 (or.±. dia. hole) 7±. -M.3 screw hole.±. (or.±. dia. hole) M3. screw hole (or.±. dia. hole) -M.3 screw hole (or.±. dia. hole) Panel hole dimensions for side-by-side mounting Panel hole dimensions for side-by-side mounting -M3. screw hole (or.±. dia. hole) -M.3 screw hole (or.±. dia. hole) General tolerance:.. Hold-down clip is packaged with the terminal socket. ds_c_en_hc: D
27 . Ordinary terminal sockets HC-terminal socket (HC-SF-K for HC) Schematic -. over hole M3 screw M. screw..7. General tolerance:.. HC3-high terminal socket (HC3-HSF-K) suitable for both HC and HC3 -. over hole Schematic M3 screw M. screw Screw hole dimensions General tolerance:.. HC-high terminal socket (HC-HSF-K) suitable for HC, and -. over hole Schematic M3 screw M. screw Screw hole dimensions 3 7 General tolerance:.. Mounting hole diagram HC-SF-K HC3-HSF-K and HC-HSF-K With a relay mounted (HC-SF-K) M3. screw hole.. (or.±. dia. hole).. -M.3 screw hole.. (or.±. dia. hole) M3. screw hole (or.±. dia. hole) -M.3 screw hole (or.±. dia. hole) Hold-down clip is packaged with the terminal socket. Panel hole dimensions for side-by-side mounting Panel hole dimensions for side-by-side mounting General tolerance:.. 7 ds_c_en_hc: D
MINIATURE RELAY FOR WIDER APPLICATIONS
TÜV Rheinland HJ MINIATURE RELAY FOR WIDER APPLICATIONS HJ RELAYS FEATURES contact arrangements Form C (for A 0 V AC), Form C (for 0 A 0 V AC)* Excellent contact reliability by Au plating Environmentally
More informationCOMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS
COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS HK RELAYS (AHK) RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Compact and high-capacity Form C: A, Form C: high capacity
More informationTV-15, 30 AMP (1 Form A) Power Relay
VDE TV-, 3 AMP ( Form A) Power Relay RELAYS Form A Plug-in type Form A type also available with 48A contact capacity FEATURES. Excellent resistance to contact welding Owing to the pre-tension and kick-off
More information20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V
20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor
More informationHG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS
20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,
More informationCOMPACT PC BOARD POWER RELAY
VDE PACT PC BOARD POWER RELAY JW RELAYS.... Compliance with RoHS Directive FEATURES Miniature package with universal terminal footprint High dielectric withstanding for transient protection:, V surge in
More informationCOMPACT PC BOARD POWER RELAY
VDE PACT PC BOARD POWER RELAY JW RELAYS..... RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Miniature package with universal terminal footprint High dielectric withstanding for
More information20 AMP POWER RELAY HG RELAYS
0 AMP POWER RELAY RELAYS RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ FEATURES. High-capacity and long life The electrical life of this high capacity is 0A 00,000 operations
More informationRelay for control panel of 1c 10A, 2c 5A and 1a 16A
HN (AHN) VDE Relay for control panel of c A, 2c A and a 6A HN RELAYS (AHN) RoHS compliant FEATURES. Slim and compact size % smaller (width and height) than existing model* (with the condition of screw
More informationCOMPACT PC BOARD POWER RELAY FEATURES. Characteristics. Initial breakdown voltage* 1. Vibration resistance
VDE PACT PC BOARD POWER RELAY JW RELAYS..... FEATURES Miniature package with universal terminal footprint High dielectric withstanding for transient protection:, V surge in µs between coil and contact
More information8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES
A MINIATURE POWER RELAY IN DS RELAY SERIES DSP RELAYS FEATURES DSPa.. DSPa DSP.... Power types added to DS relay series High switching capacity: a: A V AC / ab, a: A V AC High sensitivity: mw pick-up power
More informationDistributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility
More information8 A MINIATURE POWER RELAY IN DS RELAY SERIES
DSP A MINIATURE POWER RELAY IN DS RELAY SERIES DSP RELAYS DSPa.. DSPa.. DSP.. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Power types added to DS relay series High switching
More information30 AMP POWER RELAY WITH SPACE SAVING DESIGN
VDE 3 AMP POWER RELAY WITH SPACE SAVING DESIGN JH-RELAYS 2..2 3.. FEATURES Many safety-oriented characteristics incorporated Contact gap: more than 3 mm. inch for Form A and 2 Form A Breakdown voltage
More informationRelay for control panel of 1c 10A, 2c 5A and 1a 16A
Relay for control panel of c, 2c A and a 6A HN RELAYS (AHN) FEATURES. Slim and compact size % smaller (width and height) than existing model* (with the condition of screw terminal socket for DIN rail)
More informationTransistor drive 2c/4c 5A slim power relays
Transistor drive 2c/4c 5A slim power relays RELAYS 4 Flat type () 4 () 2 Flat type () 2 () FEATURES. Compact, slim design Use of high-performance flat electromagnetic design achieves 0.9 mm.429 inch profile,
More informationUNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550
UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY K-RELAYS.0 a UL File No.: E3 CSA File No.: LR2550.0.8 00 times more reliable than similar designs Extra long life Mechanical: more than 0 8 operations Electrical
More informationUNIQUELY DESIGNED RELAY FEATURES
UL CSA VDE Pending Pending Pending UNIQUELY DESIGNED RELAY K-RELAYS a.8 FEATURES 00 times more reliable than similar designs Extra long life Mechanical: more than 0 8 operations Electrical ( A V): more
More information1a/1c/2a/2c/5A/10A power relays for power supply
Automation Controls Catalog VDE a/c/2a/2c/a/a power relays for power supply JW RELAYS RoHS compliant Protective construction: Flux-resistant /Sealed ORDERING INFORMATION Contact arrangement : Form C a:
More informationMINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R
MINIATURE POWER RELAY IN DS RELAY SERIES DSP- RELAYS DSPa DSP SPECIFICATIONS.. DSPa Coil (polarized) (at C F) Minimum mw power coil latching mw mw power coil latching mw.... Contact Arrangement a ab a
More informationSlim compact safety relay
Slim compact safety relay SF RELAYS Slim type Max..9 Max..9 Max.. Max..99 Max.. Max.. mm inch FEATURES Forcibly guide contact structure (EN Class A TÜV recognized) Slim profile (mm inch) Compact size with
More informationSLIM COMPACT SAFETY RELAY
SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type Max. 24.945 Max. 24.945 Max. 4.575 Max. 5.969 Max. 3.52 Max. 3.52 mm inch FEATURES Forcibly guide contact structure (EN525 ClassA TÜV recognized) Slim profile
More informationSlim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type
Slim type safety relays SF RELAYS Slim type RoHS compliant Protective construction: Flux-resistant type ORDERING INFORMATION S: Slim type Contact arrangement 2: 2 Form A 2 Form B 3: 3 Form A Form B 4:
More information1a 8A, 1a1b/2a 5A small polarized power relays
Automation Controls Catalog a A, ab/a A small polarized power DSP RELAYS RoHS compliant Protective construction: Sealed type FEATURES. Compact with high contact rating Even with small mm. inch (H) mm.
More informationDistributed by: www.jameco.com 188314242 The content and copyrights of the attached material are the property of its owner. S 4 A CAPACITY, THE VARIETY OF CONTACT ARRANEMENTS S RELAYS 28. 1.12 12..472
More information1a/1c 5A/10A small power relays
VDE a/c A/A small power relays RELAYS Compliance with RoHS Directive FEATURES High electrical noise immunity High switching capacity in a compact package High sensitivity: mw (a), mw (c) High surge voltage:,
More informationDistributed by: www.jameco.com 1-8-81-44 The content and copyrights of the attached material are the property of its owner. SLIM POLARIZED RELAY TN RELAYS.551. 9.8.86 FEATURES Small header area makes higher
More information1a 8A, 1a1b/2a 5A small polarized power relays
a A, ab/a A small polarized power DSP RELAYS Compliance with RoHS Directive FEATURES. Compact with high contact rating Even with small mm. inch (H) mm. inch (W) mm. inch (L) (dimensions, high capacity
More information1a/1c/2a/2c/5A/10A power relays for power supply
a/c/2a/2c/a/a power relays for power supply JW RELAYS RoHS compliant Protective construction: Flux-resistant type/ ORDERING INFORMATION JW Contact arrangement : Form C a: Form A 2: 2 Form C 2a: 2 Form
More informationHIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY
VDE JQ HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY JQ RELAYS.77.39.. mm inch FEATURES High electrical noise immunity High switching capacity in a compact package High sensitivity: mw (a), mw () High
More informationULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage
TESTING ULTRA LOW PROFILE POLARIZED RELAY RELAYS 9...7 mm inch FEATURES Low profile mm.7 inch height High contact capacity: Surge withstand between contact and coil:, V (Telcordia) RoHS Directive compatibility
More information4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay
4 mm height! A high capacity Form C type ultra thin, super miniature relay TK RELAYS TK RoHS compliant FEATURES. Compact and flat type.6(l) 9.(W) 4.(H).47(L).34(W).7(H). High contact capacity: A 3. Outstanding
More informationCompliant with European standards 1a/1c 6A Slim power relays
PF (APF) VDE Compliant with European standards 1a/1c 6A Slim power relays PF RELAYS (APF) RoHS compliant FEATURES 1. High density mounting with mm.197 inch width Space saved with mm.197 inch slim type
More information4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay
4 mm height! A high capacity Form C type ultra thin, super miniature relay TK RELAYS TK FEATURES. Compact and flat type.6(l) 9.(W) 4.(H).47(L).4(W).7(H). High contact capacity: A. Outstanding surge resistance
More information4 AMP POLARIZED HIGH DENSITY RELAY WITH HIGH SENSITIVITY FEATURES
4 AMP POLARIZED HIH DENSITY RELAY WITH HIH SENSITIVITY SRELAYS FEATURES 28. 1...472 1.4.49 mm inch A variety of contact arrangements 2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A Latching types available
More information1a 10 A,1a1b/2a 8 A small polarized power relays
VDE a 0 A,ab/2a 8 A small polarized power relays DK RELAYS FEATURES. Compact with high capacity High capacity switching in a small package: Form A, 0 A 250 V AC; Form A Form B and 2 Form A, 8 A 250 V AC.
More informationCP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES
High Carrying Current Type Miniature Low Profile Automotive Relay CP RELAYS POWER TYPE Sealed 13.1 14.1 9..374 FEATURES Maximum carrying current of 3 A (4 mw type, 1 V applied)
More informationCompact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms
Compact size and 3A power relays for energy management and industrial equipment HE-S RELAYS New TYPICAL APPLICATIONS Photovoltaic power generation systems (Solar inverter) Uninterruptible Power Supplies
More informationLOW-PROFILE SURFACE-MOUNT RELAY
TESTING LOW-PROFILE SURFACE-MOUNT RELAY TQ SMD RELAYS.6. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6. mm.6 inch) Tape and reel
More informationCompact Relay Family with Forcibly Guided Contacts
Compact Relay Family with Forcibly Guided Contacts SF-Y RELAYS -pole ( Form A Form B, Form A Form B) -pole ( Form A Form B, 5 Form A Form B) RoHS compliant FEATURES. Forcibly guided contact structure Relay
More information4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES
4 A CAPACITY, THE VARIETY OF CONTACT ARRANEMENT RELAY 28. 1.2 12..472.4.49 FEATURE The variety of contact arrangements 2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A Latching types available High sensitivity
More information8 A MINIATURE POWER RELAY IN DS RELAY SERIES
A MINIATURE POWER RELAY IN DS RELAY SERIES RELAYS FEATURES. Compact with high contact rating Even with small mm. inch (H) mm. inch (W) mm. inch (L) (dimensions, high capacity switching is provided: a,
More informationDistributed by: www.jameco.com -8-83-44 The content and copyrights of the attached material are the property of its owner. D HIGHLY ENITIVE 5 V FCC URGE WITHTANDING INIATURE RELAY D RELAY D4E 35.4.387
More information10 A MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A 1 Form A. Initial breakdown voltage* 2. Vibration resistance.
VDE A MINIATURE POWER RELAY RELAYS a..9.9 SPECIFICATIONS power FEATURES.9 ab.9 Contact, Arrangement Form A Form A Form B Initial contact resistance, ma. (By drop V DC A) mω Contact material Gold flash
More informationNew pin layout (LT type) added. Best seller with broad lineup and AC 2000 V breakdown voltage.
Compliance with RoHS Directive FEATURES. 2, V breakdown between contact and coil The body block construction of the coil that is sealed at formation offers a high breakdown of 2, V between contact and
More information1a 16A power relay for micro wave oven
VDE 1a power relay for micro wave oven LE RELAYS (ALE) RoHS compliant FEATURES 1. Supports magnetron and heater loads. Capable for switching magnetron and heater loads found in microwave ovens. 2. Excellent
More informationLOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.
TESTING LOW-PROFILE SURFACE-MOUNT RELAY RELAYS 5.6. mm inch FEATURES Low-profile: 6 mm.36 inch in height comforming to EIA standards (Tape height: max. 6.5 mm.56 inch ) Tape and reel package is available
More informationMICRO-ISO AUTOMOTIVE RELAY
MICRO-ISO AUTOMOTIVE RELAY RELAYS Plug-in type PC board type RoHS compliant FEATURES Micro-ISO type terminals Small size: mm(l) mm(w) mm(h). inch(l). inch(l). inch(h) Wide line-up PC board and Plug-in
More informationLOW PROFILE 2 FORM C RELAY TQ RELAYS Ð Ð.008. mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC. 200 mw.
LOW PROFILE FORM C RELA RELAS 9.3 6.7.. Ð Ð.8. 9.3. Ð Ð.8 mm inch FEATURES High sensitivity: Form C: power consumption (single side stable type) Form C: power consumption (single side stable type) Surge
More information16A POWER RELAY FOR MICRO WAVE OVEN
VDE 6A POWER RELAY FOR MICRO WAVE OVEN LE RELAYS (ALE) TMP type New FEATURES. Price competitive having better price competitiveness (New 4 mw only) 2. Supports magnetron and heater loads. Switching possible
More informationRK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY
. GHz MICROWAVE RELAY RK RELAYS..79.. 9.7.3 mm inch FEATURES Excellent high frequency characteristics (Impedance 7Ω) Isolation: db (at. GHz) Insertion loss:.db (at 9 MHz) :. (at 9MHz) High sensitivity
More information1.5 GHz MICROWAVE RELAYS. FEATURES 1. Excellent high frequency characteristics. V.S.W.R. (Max.) 1.5 (at 900 MHz) Impedance
1.5 GHz MICROWAVE RELAYS RK RELAYS RoHS compliant FEATURES 1. Excellent high frequency characteristics V.S.W.R. () 1.5 (at 9 MHz) Impedance 5Ω Impedance 75Ω Insertion loss (db. ) Isolation (db. ) V.S.W.R.
More informationEN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay
EN6033-1 GWT compliant Low profile: 1.7mm inch height 1a/1c 16A power relay LZ-N RELAYS (ALZN) Protective construction: Flux-resistant type New 12. 28.8.492 RoHS compliant 1.7 (Unit: mm inch) FEATURES
More informationHIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY FEATURES. Max. operating speed. Initial. Reset time* 3 (at nominal voltage)
TETING HIGHLY ENITIVE 5 V FCC URGE WITHTANDING INIATURE RELAY D-RELAY D4E 35.4.387 5.59 DE.39 9.8.386.39 9.8.386 PECIFICATI Contact Arrangement Initial contact resistance, max. (By voltage drop 6 V DC
More informationAUTOMOTIVE RELAY WITH ISO TERMINAL ARRANGEMENT
AUTOMOTIVE RELAY WITH ISO TERMINAL ARRANGEMENT CB RELAYS Compliance with RoHS Directive FEATURES 1. This relay has an ISO (International Organization for Standardization) terminal arrangement. Terminals
More informationPARM-SIZED, 16-CHANNEL RELAY TERMINALS
Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W).
More informationHigh switching capacity 1a/1c 30A power relays
Automation Controls Catalog High switching capacity 1a/1c 3A power relays JT-N RELAYS PCB type FEATURES High switching capacity: 3 A for 1 Form A 2 contact arrangements: 1 Form A or TMP types available
More informationHIGH INSULATION RELAYS (Conforming to the supplementary insulation class of EN Standards (EN41003))
TESTING HIGH INSULATI RELAYS (Conforming to the supplementary insulation class of EN Standards (EN)) TX-D RELAYS.9.9 8...9.9 8.. FEATURES Approved to the supplementary insulation class in the EN standards
More informationHigh Sensitivity, with 100mW nominal operating power, in a compact and space saving case
High Sensitivity, with mw nominal operating, in a compact and space saving case GN RELAYS (AGN) RoHS compliant FEATURES. Compact slim body saves space Thanks to the small surface area of.7 mm.6 mm.4 inch.47
More informationSUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY
SUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY CJ RELAYS (ACJ) RoHS compliant FEATURES Smallest in its class, it is extremely compact at approx. 2/3 the size of previous products. Compared to our previous
More informationSMALL POLARIZED RELAY WITH HIGH SENSITIVITY
TESTING SMALL POLAIZED ELA WITH HIGH SENSITIVIT TF-ELAS. 9..7 mm inch FEATUES High sensitivity: 8 power (Single side stable - V type) Surge withstand: V FCC Part 68 Minimal magnetic interference allows
More informationAUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY
AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO- RELAY CV RELAYS (ACV)... Micro ISO c type.. Micro plug-in type Micro ISO a type..... Micro PCB type RoHS Directive compatibility information http://www.nais-e.com/
More informationPalm-sized, 16-channel Relay Terminals
Palm-sized, -channel Relay Terminals RELAY TERMINAL FEATURES. Possible to select relay for use in the relay terminal in accordance with load. [Mountable relay: PA relay and Power PhotoMOS (voltage sensitive
More informationHigh breakdown voltage type is available (1.5 kv between open contacts)
TESTING High type is available (.5 kv between open contacts) TX-D RELAYS New Compliance with RoHS Directive FEATURES. Lineup now includes high type that achieves between open contacts of,5 V AC. between
More informationMINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A. 1 Form B. Initial breakdown voltage* 2 8 A 250 V AC 8 A 30 V DC 250 V AC, 30 V DC
VDE MINIATURE POWER RELAY DKRELAYS a..9.9 ab.9.9 FEATURES Large capacity in small size: A V AC (a) High sensitivity: mw nominal power High breakdown, Vrms between contacts and coil, Vrms between open contacts
More informationRT-3 UNIT RELAY 4-POINT TERMINAL
Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA Relay type, PhotoMOS Power (Voltage sensitive type)] RT-3 Unit relay -point Terminal [PA relay, PhotoMOS Power (Voltage sensitive
More informationMicro-ISO Automotive Relay. (Unit: mm inch)
Micro-ISO Automotive Relay CM RELAYS Flux tight/sealed.. FEATURES Micro-ISO type terminals and small size Wide line-up Compact and high-capacity switching... TYPICAL APPLICATIONS
More informationSuitable for lighting and motor load, 1 Form A 50A latching relays
Suitable for lighting and motor load, 50A latching relays DJ-H RELAYS (ADJH) 9.0 5 1 0.2 9.0 5 New 1 FEATURES 1. High inrush capability Tungsten load (TV-20 class) Electronic ballast load (NEMA10) Capacitive
More informationHIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE
HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE RELAYS (60A type only) 0A PC board type 0A TM type 60A Screw terminal type 80A Connector type 300A Connector type FEATURES. High-, high-current
More informationRelays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:
RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator
More informationCAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES
CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY EV RELAYS (AEV) 80A A 0A FEATURES. High-, high-current control possible 0 high- switching cutoff has been achieved thanks to a sealed construction
More informationHIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY
HIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY SX RELAYS (ASX) 1. FEATURES 1. High contact reliability over a long life has been made possible for low level loads. Using a low level
More informationHIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE
HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE RELAYS (60A type only) A PC board type A TM type 60A Screw terminal type 80A Connector type 300A Connector type Compliance with RoHS Directive
More informationAUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY
CV (ACV) Discontinued as of August, AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO- RELAY CV RELAYS (ACV)..... Micro ISO c type Micro ISO a type..... Micro plug-in type Micro PCB type Products to be discontinued.
More informationAUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY FEATURES
AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO- RELAY CV RELAYS (ACV) Micro ISO c type Micro ISO a type Micro plug-in type Micro PCB type FEATURES Low profile:. mm(l) mm(w). mm(h) inch(l). inch(w). inch(h) Low
More informationAUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY
AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO- RELAY CV RELAYS (ACV) Micro ISO c type Micro ISO a type Micro plug-in type Micro PCB type FEATURES Low profile:. mm(l) mm(w). mm(h). inch(l). inch(w). inch(h) Low
More informationHIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES
HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE (60A type only) RELAYS A PC board type 80A Connector type 60A Screw terminal type A TM type 300A Connector type RoHS Directive compatibility
More informationLoad for air conditioner 1a 20A power relays
VDE Load for air conditioner 1a A power relays LF RELAYS (ALF) TMP type PCB type RoHS compliant FEATURES 1. Ideal for compressor and inverter loads 1) Compressor load: A 5V AC ) Inverter load: A V AC,
More informationPCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique
More informationCompact Flat Size Relay for Automotive. (Unit: mm inch)
Compact Flat Size Relay for Automotive CP RELAYS Sealed 13.1.1 9..374 13.1.1 1..413 FEATURES Compact flat type PC board terminal type: 9. mm.374 inch Compact and High
More information1 GHz capable, 3 W carrying power (at 1 GHz), 50Ω impedance and 2 Form C relays
1 GHz capable, 3 W carrying power (at 1 GHz), 5Ω impedance and 2 Form C relays RA RELAYS (ARA) 9.7 14.7.382.579 5.9.232 mm inch RoHS compliant Protective construction: Sealed type ORDERING INFORMATION
More informationIDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)
IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact
More informationPCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.
More informationRelays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.
RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in
More informationRU Series Universal Relays
Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal
More informationG6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.
Miniature High Capacity Relays with SPST-NO 0A and SPST-NO + SPST-NC A SPST-NO 0A and SPST-NO + SPST-NC A for power switching and output that satisfy the needs for space-saving. Small High-capacity Relays
More informationSUPER MINIATURE TWIN TYPE AUTOMOTIVE RELAY FEATURES
SUPER INIATURE TWIN TYPE AUTOOTIVE RELAY CT RELAYS (ACT) 7.... Twin type ( terminals) 7.. 7... FEATURES Small & slim size Twin type: 7.(L).(W) (H)mm.(L).(W).(H)inch Slim c type: 7.(L) 7.(W) (H)mm.(L).(W).(H)inch
More informationPower PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).
Power PCB Relay Subminiature 20 L x 9.90 W x 9.90 H mm (0.79 L x 0.39 W x 0.39 H in) Low power consumption (200 mw) Sealed construction permits automatic soldering and cleaning of the PC board High-capacity
More informationRelays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection
RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications
More informationACCESSORIES. Type No. of poles Item Part No. Performance. Contact arrangement 1 Form C 2 Form C Max. continuous current (Ambient temperature:
ACCESSORIES HN RELAYS (Sockets and DIN rail s) TYPES Type No. of poles Item Part No. PC board DIN rail Standard packing: Carton: 0 pcs.; Case: 00 pcs. Note: Certified by UL/C-UL -pole HN PC board AHNA3
More information200A type has been added. High Capacity of Max. 1,000 V DC Cut-off Possible
EP (A, A (AEP) and 80A types) 0A type has been added. High Capacity of Max.,000 V DC Cut-off Possible EP RELAYS (AEP) A PC board type A TM type A TM type 80A type New 0A type 300A type RoHS compliant FEATURES.
More informationRT-3 UNIT RELAY 4-POINT TERMINAL
Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] -point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable
More informationHigh Capacity of Max. 1,000 V DC Cut-off Possible
EP (A (AEP) and 80A types) High Capacity of Max.,000 V DC Cut-off Possible EP RELAYS (AEP) A PC board type A TM type New A TM type 80A type 300A type Compliance with RoHS Directive FEATURES. High-, high-current
More informationRJ Series Slim Power Relays
RJ Series RJ Series Slim Relays Circuit Breakers Terminal Blocks Timers Display Lights Switches & Pilot Lights Compact and rugged power relays. Large switching capacity. Compact housing only.7-mm wide.
More informationSlim type SSR for 1 A and 2 A control AQ-G RELAYS
VDE Slim type SSR for 1 A and A control AQ-G RELAYS ORDERING INFORMATION current 1: 1 A : A RoHS compliant voltage : 75 to 6 Vrms 1: Zero-cross (3, V) : Random (3, V) Control voltage 5: to 6 V DC 1: 9.6
More informationMK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure
Compact Power Relays MK CSM_MK_DS_E A Wide Variation of Octal Pin Power Relays Encased Relays unified to an AC rating (/ VAC at /Hz and / VAC at / Hz). Easy to install, wire, and use. Highly durable with
More informationLOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.
TESTING LOW PROFILE 2 FORM RELY TQ-RELYS 9.34 26.7 +.4..2 +.6.8 4. 9.34 +.4.2 +.6.8 FETURES High sensitivity: 2 Form : 4 power consumption (single side stable type) 4 Form : 28 power consumption (single
More information2 AMP. HIGH CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE FEATURES. Characteristics. Initial breakdown voltage
TESTING 2 MP. HIGH PITY RELY WITH HIGH SURGE VOLTGE & HIGH REKDOWN VOLTGE TX-RELYS 8.4.33 FETURES reakdown voltage between contacts and coil: 2, V Surge withstand between contacts and coil: 2, V High contact
More informationLow profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b
Low profile safety relay with forcibly guided double contacts SFN4D RELAY 3.3 33.0 FEATURES Relay complies with EN 020, Type B. Polarized magnet system with snap action function Tolerance ±0.3 mm Weight
More informationULTRA LOW PROFILE 2 AMP. POLARIZED RELAY. mm inch. Initial breakdown voltage
TESTING ULTR LOW PROFILE MP. POLRIZED RELY TK-RELYS.6.47 9..34 4..7 FETURES Low profile 4 mm.7 inch height High contact capacity: Surge withstand voltage between contact and coil: V (ellcore rating) SPEIFITIS
More information