PARM-SIZED, 16-CHANNEL RELAY TERMINALS

Similar documents
Palm-sized, 16-channel Relay Terminals

RT-3 UNIT RELAY 4-POINT TERMINAL

RT-3 UNIT RELAY 4-POINT TERMINAL

TV-15, 30 AMP (1 Form A) Power Relay


MINIATURE RELAY FOR WIDER APPLICATIONS

SLIM COMPACT SAFETY RELAY

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

Compliant with European standards 1a/1c 6A Slim power relays

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

Slim compact safety relay


HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

LOW-PROFILE SURFACE-MOUNT RELAY

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay


RK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

COMPACT PC BOARD POWER RELAY

High Sensitivity, with 100mW nominal operating power, in a compact and space saving case

New pin layout (LT type) added. Best seller with broad lineup and AC 2000 V breakdown voltage.

1.5 GHz MICROWAVE RELAYS. FEATURES 1. Excellent high frequency characteristics. V.S.W.R. (Max.) 1.5 (at 900 MHz) Impedance

1 GHz capable, 3 W carrying power (at 1 GHz), 50Ω impedance and 2 Form C relays

AQ-R SOLID STATE RELAY FEATURES

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

16A POWER RELAY FOR MICRO WAVE OVEN

8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

Transistor drive 2c/4c 5A slim power relays

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

4 AMP POLARIZED HIGH DENSITY RELAY WITH HIGH SENSITIVITY FEATURES

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

COMPACT PC BOARD POWER RELAY

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

LOW PROFILE 2 FORM C RELAY TQ RELAYS Ð Ð.008. mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC. 200 mw.

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

COMPACT PC BOARD POWER RELAY FEATURES. Characteristics. Initial breakdown voltage* 1. Vibration resistance

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

10 A MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A 1 Form A. Initial breakdown voltage* 2. Vibration resistance.

HIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY

HC RELAY PRODUCT TYPES

1a/1c 5A/10A small power relays

SMALL POLARIZED RELAY WITH HIGH SENSITIVITY

1a 16A power relay for micro wave oven

Compact Relay Family with Forcibly Guided Contacts

High switching capacity 1a/1c 30A power relays


DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

UNIQUELY DESIGNED RELAY FEATURES

MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A. 1 Form B. Initial breakdown voltage* 2 8 A 250 V AC 8 A 30 V DC 250 V AC, 30 V DC

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Timers GE1A. GE1A Series ON Delay Timers Single Function

HIGH INSULATION RELAYS (Conforming to the supplementary insulation class of EN Standards (EN41003))

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

1a 8A, 1a1b/2a 5A small polarized power relays

FPC connectors (0.3mm pitch) Front lock with FPC tabs

High breakdown voltage type is available (1.5 kv between open contacts)

6mm Interface Relays RV8 Series

20 AMP POWER RELAY HG RELAYS

ULTRA LOW PROFILE 2 AMP. POLARIZED RELAY. mm inch. Initial breakdown voltage

SUNSTAR 传感与控制 TEL: FAX: POWER PhotoMOS RELAYS (Voltage Sensitive Type) Photo

HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY FEATURES. Max. operating speed. Initial. Reset time* 3 (at nominal voltage)

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

For FPC. FPC connectors (0.2mm pitch) Back lock

High Capacity of Max. 1,000 V DC Cut-off Possible

SUPER MINIATURE TWIN TYPE AUTOMOTIVE RELAY FEATURES

3 GHz capable, 10 W carrying power (at 3 GHz), 50Ω/75Ω impedance and 1 Form C relays

1a/1c/2a/2c/5A/10A power relays for power supply

1a 8A, 1a1b/2a 5A small polarized power relays

HIGH CAPACITY, LONG LIFE SUBMINIATURE SWITCH

RU Series Universal Relays

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

2 AMP. HIGH CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE FEATURES. Characteristics. Initial breakdown voltage

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

For FPC. FPC connectors (0.3mm pitch) Back lock

LOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

SUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

Capacitive Proximity Sensor

1a/1c/2a/2c/5A/10A power relays for power supply

MICRO-ISO AUTOMOTIVE RELAY

AUTOMOTIVE RELAY WITH ISO TERMINAL ARRANGEMENT

Safety Precautions. Copyright / Trademarks

200A type has been added. High Capacity of Max. 1,000 V DC Cut-off Possible

1a 10 A,1a1b/2a 8 A small polarized power relays

10A to 40A hockey puck type FEATURES

POWER PhotoMOS RELAYS 1-channel (Form A) Type FEATURES

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

Transcription:

Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W). (D).0 (H). inch. The compact design contributes to equipment downsizing. Incorporates PA Relays with highsensitivity twin contacts and Au-cladding: The Relay Terminal incorporates mm. inch wide PA relays. The PA relay features high sensitivity ( V type = 0 mw, V type = 0 mw) and twin contacts with Au-cladding, which combine to ensure high reliability under low-level loads. Available in input and output devices Available in Pressure connector connect type and wire-direct connect type: Pressure connector connect type has a single common for four I/O channels. The Wire-direct connect type has a single common for each I/O channel. Incorporates a surge absorber: The RT- Series incorporates a surge absorber to protect the programmable controller internal electronics from inductor turn-off surges. RT- RELAY TERMINAL Equipped with LED indicator lights: LED indicators allow the user to identify the relay status at a glance. Comes with AXM connector (long lever version): The RT- Series comes with the AXM connector (complying with the MIL standard) for single connections. Cable designed for use with AXM connectors are also available. Ease of mounting on DIN rails: The DIN rail mounting hook of relay terminal is provided with a release/retention mechanism to ease mounting and removal. Available with a wide variety of cables: A wide variety of assembled cables offers compatibility with our programmable controllers, and wire-pressed terminal cables provide compatibility with other controllers. ORDERING INFORMATION Ex. RTS M C ID V Installation type Blank: DIN rail mounting type M: Direct mounting type Termination type I/O type No. of I/O channels Rated voltage Blank: Pressure connector connect type C: Wire-direct connect type ID: Input device (DC) OD: Output device (DC) : channels V: V DC V: V DC Note: Please consult us regarding minus common types for input.

TYPES. DIN Rail Mounting Type ) Pressure connector connect type ) Wire-direct connect type. Direct Mounting Type ) Pressure connector connect type ) Wire-direct connect type. Interface Relay RATINGS I/O type Rated voltage Part No. Input device Output device. Relay coil specifications (per PA relay) V DC RTS-ID-V V DC RTS-ID-V V DC RTS-OD-V V DC RTS-OD-V I/O type Rated voltage Part No. Input device Output device V DC RTS-C-ID-V V DC RTS-C-ID-V V DC RTS-C-OD-V V DC RTS-C-OD-V I/O type Rated voltage Part No. Input device Output device V DC RTS-M-ID-V V DC RTS-M-ID-V V DC RTS-M-OD-V V DC RTS-M-OD-V I/O type Rated voltage Part No. Input device Output device V DC RTS-MC-ID-V V DC RTS-MC-ID-V V DC RTS-MC-OD-V V DC RTS-MC-OD-V Type Rated voltage Part No. PA relay Rated coil voltage Pick-up voltage (at 0 C F) V DC PAa-V V DC PAa-V Drop-out voltage (at 0 C F) Rated exciting current (±0%) Coil resistance (±0%) (at 0 C F) pc. 0 pcs. pc. 0 pcs. pc. 0 pcs. pc. 0 pcs. pcs.,000 pcs. Rated power consumption RT- Max. continuous voltage (at C F) V DC V DC less than 0% more than % 0 ma,00 Ω 0 mw. V DC of nominal voltage of nominal voltage. ma,00 Ω 0 mw. Note: The LED draws a drive current of approximately ma per channel. When calculating the supply capacity required, include the total current consumed by the LEDs.. Contacts (per PA relay) Specification Item Performance Rated control capacity (resistive load) A 0 V AC, A 0 V DC Maximum allowable contact power 00 VA (AC), 0 W (DC) (resistive load) Contact rating Maximum allowable contact voltage 0 V AC, 0 V DC Maximum allowable contact current A Minimum load (ref. value) 00 mv 00 µa Expected life (minimum operations) 0 : A 0V AC 0 : A 0V DC Electrical (resistive load) 0 : A 0V AC 0 : A 0V DC Mechanical (at 0 cpm) 0

RT- PERFORMANCE Item Input Output Initial Insulation resistance (Min.) Initial breakdown voltage (Min.) Vibration resistance Between connector terminals 00 MΩ (excluding battery at 00 V DC megger) 00 MΩ (excluding battery at 00 V DC megger) Between unlike poles on the terminals 00 MΩ (at 00 V DC megger) 00 MΩ (at 00 V DC megger) Between like poles on the terminals (for output) 00 MΩ (at 00 V DC megger) Between connector terminals,000 Vrms for min. (excluding battery),000 Vrms for min. (excluding battery) Between unlike poles on the terminals,00 Vrms for min.,00 Vrms for min. Between like poles on the terminals (for output),000 Vrms for min. Destructive Functional 0 to Hz at double amplitude mm.0 inch 0 to Hz at double amplitude mm.0 inch 0 to Hz at double amplitude mm.0 inch 0 to Hz at double amplitude mm.0 inch Shock resistance Destructive Min. m/s {0G} Min. m/s {0G) Functional Min. m/s {0G} Min. m/s {0G) Superimposed power noise Min.,000 V* Min.,000 V* Superimposed I/O noise Min.,000 V* Min.,00 V* Ambient temperature 0 C to + C + F to + F 0 C to + C + F to + F Ambient humidity % to % R.H. (Not condensing) % to % R.H. (Not condensing) Storage temperature 0 C to +0 C F to + F (Not freezing and condensing) 0 C to +0 C F to + F (Not freezing and condensing) Terminal screw fasten torque 0. to 0. N m ( to kgf cm) for pressure connector connect type; 0. to 0. N m ( to kgf cm) for wire-direct connect type Coil surge absorber Diode ( A, 00 V) Diode ( A, 00 V) Cross connection protecting diode A, inverse voltage 0 V. A, inverse voltage 0 V Weight Approx. 00 g. oz Approx. 00 g. oz *According to in-house measurement. Notes:. The value of breakdown voltage and insulation resistance is the initial one.. Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere. This may cause some troubles like insulation failure of the socket or the print circuit board. Take care under this condition. Below 0 C F, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition. TERMINAL BLOCK. Pressure connector connect type Applicable electrical wire 0. to. mm.0 to.0 inch Applicable wire-pressed terminals dia. min.. dia. min. mm inch. Wire-direct connect type Strip the wire ends as follows: Stripping length to 0 mm. to. inch Recommended wire 0. to. mm.00 to 0. inch 0. to. mm dia..0 to.0 inch. max..0 max. min.. min.. max..0 max... min.. min... min.. min. DATA. Maximum value for switching capacity per PA relay (output). Life curve per PA relay (output) Contact current, A.0.0.0.0 0. 0. 0. 0. Resistive DC load Resistive AC load No. of operations, 0 00 0 0 0 0 V AC resistive load 0 V DC resistive load 0 V AC resistive load 0 0 0 00 00 00 Contact voltage, V 0..0.0.0 Switching current, A

DIMENSIONS Dimensions are common to both input and output module.. DIN rail mounting Pressure connector connect type. ±0.. ±.0 RT- mm inch 0 A B C D E F ±.0 ±.0 ±.0 ±.0. ±0.. ±0..00 ±.0. ±.0 ±. ±.0 -M. terminal screw. ±0..0 ±.0. ±0.. ±.0 Wire-direct connect type 0 A B C D E F ±.0 ±.0.0 ±0..00 ±.0 ±. ±.0 + 0+ + + + + + + + + + A+ B+C+ D+ E+ F+ - 0- - - - - - - - - - A- B- C- D- E- F-. ±0.. ±.0. Direct mounting Pressure connector connect type ±. ±.0 ±0.. ±.00 (M. screw mounting pitch) -M. screw mounting position 0 A B C D E F ±.0 ±.0. ±0.. ±0..00 ±.0. ±.0 ±. ±.0 -M. termibnal screw. ±0.. ±.0

RT- Wire-direct connect type mm inch ±. ±.0 ±0.. ±.00 (M. screw mounting pitch) -M. screw mounting position 0 A B C D E F ±.0 ±.0.0 ±0..00 ±.0 ±. ±.0 + 0+ + + + + + + + + + A+ B+C+ D+ E+ F+ - 0- - - - - - - - - - A- B- C- D- E- F-. ±0.. ±.0 SCHEMATIC (common to both DIN rail mounting and direct mounting). Pressure connector connect type ( commons) Input module Connector pin Connector pin layout (TOP VIEW) LED0 LED LED LED LED LED LED LED LED LED LEDA LEDB LEDC LEDD LEDE LEDF 0 0 0 0 VCC 0- - COM+ - - - A- COM+ D- F- GND - - - - COM+ - B- C- E- COM+ Terminal portion Note: Above terminal number is not marked on the terminal itself. Wiring should be done according to the O mark.

Output module RT- Connector pin 0 0 Connector pin layout (TOP VIEW) LED0 LED LED LED LED LED LED LED LED LED LEDA LEDB LEDC LEDD LEDE LEDF 0 0 VCC 0+ + COM- + + + A+ COM- D+ F+ GND + + + + COM- + B+ C+ E+ COM- Terminal portion Note: Above terminal number is not marked on the terminal itself. Wiring should be done according to the O mark.. Wire-direct connect type (Individual common) Input module Connector pin Connector pin layout (TOP VIEW) 0 0 0 0 LED0 LED LED LED LED LED LED LED LED LED LEDA LEDB LEDC LEDD LEDE LEDF VCC 0+ + + + + + + + + + A+ B+ C+ D+ E+ F+ GND 0- - - - - - - - - - A- B- C- D- E- F- Terminal portion Note: Above terminal number is not marked on the terminal itself. Wiring should be done according to the O mark.

RT- Output module Connector pin 0 0 Connector pin layout (TOP VIEW) LED0 LED LED LED LED LED LED LED LED LED LEDA LEDB LEDC LEDD LEDE LEDF 0 0 VCC 0+ + + + + + + + + + A+ B+ C+ D+ E+ F+ GND 0- - - - - - - - - - A- B- C- D- E- F- Terminal portion Note: Above terminal number is not marked on the terminal itself. Wiring should be done according to the O mark. CAUTIONS FOR USE. When equipped with Power Photo- MOS relay voltage sensitive type Since the Power PhotoMOS relay voltage sensitive type does not require the current-controlling resistance on the input side, it can be used together with PA relays on -point unit relays (PA relay types) or RT- relay terminals. When connecting Power PhotoMOS relay voltage sensitive types to -point relays (PA relay types) or RT- relay terminals, it will be necessary to be careful of load currents (since it will be a close connection). Be sure to use within the range given in the load currents and ambient temperature characteristics graphs given below. Power PhotoMOS relay (voltage sensitive type) load currents and ambient temperature characteristics When equipped on -point unit relay (PA relay type) or RT- relay terminal. ) DC type, V input Load current, A 0 0 AQZ0D AQZ0D AQZ0D AQZ0D ) DC type, V input Load current, A 0 0 0 0 0 0 0 0 0 0 Ambient temperature, C F AQZ0D AQZ0D ) AC/DC type, V input Load current, A 0 0 AQZ0D AQZ0D AQZ0D AQZ0D ) AC/DC type, V input Load current, A 0 0 0 0 0 0 0 0 0 0 Ambient temperature, C F AQZ0D AQZ0D AQZ0D AQZ0D AQZ0D AQZ0D 0 0 0 0 0 0 0 0 0 0 0 0 Ambient temperature, C F 0 0 0 0 0 0 0 0 0 0 0 0 Ambient temperature, C F

. Operating environment ) Use the product at ambient operating temperature between 0 C and C F and F. (When installing in the control panel, take heat release into due consideration. Installing of the product at 0 degrees to the control panel is recommended. When installing the product horizontally or placing it on a heating unit, use a cooking fan.) ) Keep the supply voltage within the range of 0% V to 0% V of the rated voltage. ) Keep the product as far as possible from power cables, high tension equipment, power equipment, equipment with transmitting devices such as amateur radios, or equipment which generates a large switching surge. ) The main unit is made of resin; therefore, do not use it in areas where it may come in contact with (or be exposed to) organic solvents such as benzine, thinner, and alcohol or strong alkaline substances such as ammonia and caustic soda. ) Do not use the product in areas where it may be exposed to flammable gases, corrosive gases, excessive dust, or moisture, or areas where it may be subjected to strong vibration or shock.. Dropping If a unit is dropped be sure to check its external appearance and characteristics before using it.. Installing and removing the module ) Firmly insert the module into the socket with the terminals going in the direction of the blade receptacles. ) The module can be easily removed using the removal key. () Insert the removal key into the socket slots. () Pull the removal key up to remove the module.. Wiring and circuit configuration ) Make all connections according to the schematic. Polarity should be observed when wiring DC type. ) Use of wire-pressed terminal is recommended for connections to pressure connector connect type. For the wire-direct connect type, strip wire ends to the specified length. ) When wiring power lines or power cables, twisted pair treatment (standed wire treatment) should be done in order to improve noise resistance. ) When the load output device is an inductive load type, installing a diode and surge absorber to both ends of the load is recommended. ) In order to improve noise resistance, class grounding of the control panel is recommended. ) Do not pass the wiring over the surface of the case. (When unavoidable, keep the wire at least cm. inch away from the surface of the case.) ) Turn off the power before connecting/ disconnecting connector cables. ) With some types of control devices, leakage current may cause the relay to fail to turn off after the control input is turned off. Make sure that the relay turns off after the control input is turned off. RT-. Installation ) Perform mounting hole cutout according to the panel cutout drawings. ) When installing the unit on a DIN rail, use the DIN rail locking lever on the side of the unit. Installation is accomplished by simply fitting the unit onto the rail and pressing gently. DIN rail Hook the holders on the unit over the DIN rail. First push in the DIN rail locking lever. DIN rail locking lever Press the unit onto the DIN rail. ) To remove the unit from the DIN rail, use a flat head screwdriver to pull out the DIN rail locking lever. Remove the unit from the DIN rail. Insert the tip of the flat head screwdriver into the slot in the DIN rail locking lever. Move the screwdriver in the direction of the arrows, and pull out the lever.. Transporting and storage ) If the product is subjected to extreme vibration while being transported, the relays may become detached, the lead may become bent, and the unit may become damaged. Handle the inner and outer boxes with care. ) If the product is stored in an extremely adverse environment, visible defects and deterioration of performance characteristics may result. We recommend the following storage conditions. Temperature: to 0 C to F Humidity: Max. 0% R.H. Environment: No hazardous substances such as sulfurous acid gases and little dust.