ABW-4-SSP ABW-5-SSP 5 ABW-6-SSP 6 ABW-7-SSP 7 ABW-4-ESP ABW-5-ESP 5 ABW-6-ESP 6 ABW-7-ESP 7 ABW(*)24HSP ABW(*)36HSP. Furnished in pairs with hardware.

Similar documents
99 Straight Sections 100 fittings, splices & connectors. 103 fasteners

Open Up Your View With CABLE SYSTEMS

Installation Instructions for Solar Snow Pad (SSP-T-3)

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Installation Instructions - Model V4JSD 1

Factory Assistance: Phone: Fax: Page 1

Inc. BT Series. BW Series

Wire Mesh Cable Tray System for Channeling of Cable Wiring

OXYGEN INSTALLATION. Revision date

Experience the Hi-Lite Advantage

Horizontal Cable Systems

SolarMount (E)volution

Superstrut Stainless Steel Channels and Accessories

M4 Hex Nut [ ] M4 T-Nut 20 [20-044] Appx. 1. 3mm. 20 Series profiles (1 per hole) (1 per hole) Ordering Information

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

Cat. No. A1200 A1200-S A1200-KO. Finishes & Materials. E142-1/4x100EG 1/4 x 1 A100-5/16EGC A100-3/8EGC. Standard Finish: Electrogalvanized

STRUCTURAL HOLDING, CT6 TOOL BOARD, AND CART ASSEMBLY

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

Leveling Feet, Base Plates and Casters

Beam and Purlin Clamps Beam Clamps

Horizontal Cable Systems

SECTION CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY

SolarMount-I INSTALLATION MANUAL Broadway Boulevard NE Albuquerque, NM USA A HILTI GROUP COMPANY

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013

ATLANTIS RAIL Contact Information

Rayport G Eco Dealer Kit

AWNING SYSTEM INSTALLATION INSTRUCTIONS ALL VERTICAL WALLS

Track Rack. * Track Racks are not lockable

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Installation Instructions

Kwik-Lock. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

SIGN MOUNTED BEACON SIG-027-A SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST DETAIL "A-1"

B Connectors. Automation. Structural Framing System Connectors & Fasteners

A E D X E X C A C B A L B E L E T R T A R Y

CABLE TRAY SYSTEM 248

UNIFIED FACILITIES GUIDE SPECIFICATIONS

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

May 14, Installation Manual

Light Structural Main Runner Light Structural Infill Tees. Straight Connector. Strut Structural Tee thread

Classic Roll Tarp. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

CNC Router Parts PRO Machine Kit Cable Track Installation Instructions

Husky Techtray. S m a r t C a b l e M a n a g e m e n t. Introduction Pg. 169

ExpressTray. Steel Wire Basket Tray. Configuration Methods. B Connection of Straight Sections. A Quiklok Tray Connections at Record Speed

Sun Control-Solar Eclipse-Solar Shelf

Transmission Line Support Systems

salto safe 4028 A12 Turn-tilt windows

User Instructions Multiline Otter Scoreboard Caddy Assembly

WALCOOM. Walcoom Corporation SAFETY GRATING.

table of contents Sliding Door Accessories Page Latches & Snuggers Stay Rollers Brackets & Stops

Classic Roll Tarp. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

INSTALLATION INSTRUCTIONS

PRODUCT INFORMATION Penco Wide-Span Shelving

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

AUXILIARY FRAMING AND ACCESSORIES

Installation Instructions

Storefront Installation Guide

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

TREX ENHANCE RAILING (Also Applies to Trex Select Railing) Installation Instructions

Ground Clamps Cable Tray

KwikSplice aluminum cable tray system

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

FOR PROFESSIONAL GARAGE DOOR INSTALLERS

2x Bottom Bracket. 1x Rail Support STEP 1 STEP 2

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger

WG-4 Wall Guard Installation Instructions

Wire Mesh Cable Tray System for Channeling of Cable Wiring

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High

Installation Instructions

3 11/16" [94.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY 6" [152.4mm]

Height Adjustable Benching End Panel and Utility Pole

Pole Mount Installation Manual

Concealed Thru-Roof Assemblies

Before Assembling the Storage Wall

cutoff simplifying Material handling Measuring systems

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD

Cable Tray. SF/273, 16th mile stone, Kavaraipettai-Satyavedu road, Thiruvallur T /52/53/54 F

MSP-WRTIDSKY1 Light Weight Suspended Ceiling Kit for use with Island Display Skybox

EZYMESH CABLE MESH EZYMESH. Cable Support Systems

SKT-SP Tangent Terminal

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY

Catalog. Mounts. Racking. Systems. Rail Clamps L-Feet. Pub. C10001-V013

ALUMINUM RAILING INSTALLATION INSTRUCTIONS. 1) Check Contents Of Packages: Verify that all parts have arrived and that they match the packing list.

THE TRADEMARK NAME IN VINYL FENCE. Maintenance Free. Transferable Lifetime Warranty. No Painting Increased Property Value Cost Effective Beautiful!

2-PIECE STAIRWAY ASSEMBLY

INSTALLATION INSTRUCTIONS. Level Rail With Cap: Page 2 Level Rail Without Cap: Page 8 Stair Rail: Page 12

VPN: ISBXLR. Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Swifts cable ladder ancillary items

Intex Engineered Pergola System Installation Instructions. NOTE: See Appendix for Foundation Requirements

INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R

THE CASCADE & SLINGER FUNSLIDES

POWER PEAK TM ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation. Version 1, Rev D P/N

SECTION CABLE TRAYS

LPR System Installation instructions

System 3000 specifications

NX7 SERIES 5-1/2 HANDRAIL

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

CABLE RUNWAY & TRAY PRODUCTS

Rayport G Eco Dealer Kit

Transcription:

Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. ABW--SSP ABW--SSP ABW-6-SSP 6 ABW-7-SSP 7 Snap-In Expansion Splice Plate Allows for a 1 in. expansion or contraction of tray system. Packaged in pairs with zinc plated hardware. ABW--ESP ABW--ESP ABW-6-ESP 6 ABW-7-ESP 7 Horizontal Adjustable Plate Adjustable hinge plates provide maximum horizontal installation flexibility. ABW(*)2HSP ABW(*)36HSP (*) Insert Height. 6 7 For Tray Width 6 in. to 2 in. inclusive 30 in. to 36 in. inclusive Furnished in pairs with hardware. Vertical Adjustable Plate Hinged vertical plates provide maximum flexibility for changes in elevation. Furnished in pairs with hardware. ABW--VSP ABW--VSP ABW-6-VSP 6 ABW-7-VSP 7 T&B aluminum cable tray is composed of two distinct systems H-Style and U-Style. These systems are interchangeable. w w w. t n b. c a A99

Box to Tray Plates Designed to secure tray to electrical panels or boxes, walls or end supports. Furnished in pairs with hardware. ABW--BSP ABW--BSP ABW-6-BSP 6 ABW-7-BSP 7 Closure End Plate Reducing Splice Plate Provides closure for any tray end. Packaged with hardware. Offset Straight Used in pairs to provide a straight reduction or used with a standard splice plate for an offset reduction. Packaged with hardware. NOTE: (*) For offset reduction: insert width to be reduced. For straight reduction: insert 1/2 width to be reduced (2 required). Example: ABW-03-RSP = 3 in. offset reducer. Widths of Tray (in.) ABW-(*)-CEP 06 ABW-(*)-CEP 09 ABW-6(*)-CEP 6 12 ABW-7(*)-CEP 7 18 2 30 36 (*) Insert width of Tray. ABW-(*)-RSP ABW-(*)-RSP ABW-6(*)-RSP 6 ABW-7(*)-RSP 7 Step Down Splice Plate Connects siderails of different heights. Hardware included. ABW(*)(**)SDS (*) Height 1. (**) Height 2. NOTE: Height 1 is greater then Height 2. 6 7 T&B aluminum cable tray is composed of two distinct systems H-Style and U-Style. These systems are interchangeable. A100

Mid-Span Splice Plate Mid-Span Splice Plate Features: Factory pre-drilled side rails for above series easy installation. Allows random connexion location. Tested loading 160 lb./ft., based on a 20 ft. simple beam test with 1. safety factor (tested with AH66 series). Supplied with stainless steel type 316 hardware. Available on ladder, vented or solid tray style. Only available in the following series of aluminum tray: AH6, AH6, AH66 and AH76*. *(20 ft. Support Span only). The Splice Plate 3/8 in.-16 x 3/ in. SS316 carriage bolt and serrated flanged nuts Cable Tray Mid-Span Slice Plate Reinforcing plate Part #: ABW6SSPMS 3/8 in.-16 x 1 in. SS316 carriage blot and serrated flanged nuts A101

Mid-Span Splice Plate Typical Installation of Mid-Span Splice Plate These heavy-duty splice plates are designed to allow random splice location, including the midspan for 20 ft. support spans. These splices are available for all long-span, ladder, vented or solid tray style. Ordering Information Straight Section Number Selection (AMS-6)-2-L09-6 Style Series Depth Width Bottom Type Length AMS Mid-Span Splice Prefix Series Series 6 Series 6 7 Series 7 6 (6 in.) 06 (6 in.) 09 (9 in.) 12 (12 in.) 18 (18 in.) 2 (2 in.) 30 (30 in.) 36 (36 in.) L06 6 in. rung spacing L09 9 in. rung spacing L12 12 in. rung spacing V Ventilated S Solid Trough 6 (6 meters) 288 (2 ft.) To order straight sections with Mid-Span Splice Plate, replace AH in the standard part number with AMS. Example: AH662L12-6 AMS662L12-6 A102

Place splices directly over supports No additional support required Over Support Splice Adaptor (Beam Installation) A103

Standard 1/ Span Typical Installation Supports are placed at 1/ span (2%). Expansion joints need extra support at 1/2 span to prevent excessive deformation of the tray under heavy loads. New Over Support Typical Installation Supports are placed right under the joints of the installation. The splice adaptor allows a wider distribution of the support, therefore minimizing the stress and deflection of the assembly. Standard Splice Plate 2% Span Standard Splice Plate 2 Over Support Splice Adaptor Span Span Expansion Splice Plate NOTE: Independent of the installation method chosen, AU/AH6 straight sections are CSA approved for Class E loading. (100%) Beam Installation ABW6-OSS-B BOTTOM VIEW Required on expansion joint only 1 2 3 3 6 Required on anchored joint only Installation Components 1. Bonding jumper 2. Splice plate 3. Over support splice adaptor. Beam clamp. Hold down clamp 6. Structural beam 7. Strut (see right page) A10

Expansion % Span Splice Plate 2% Span Standard Splice Plate Extra Support Required Over Support Splice Adaptor Standard Splice Plate Over Support Splice Adaptor NEMA VE2: Splice joints should be designed and placed so as to maximize the rigidity of the cable tray over support. Splice plates and adaptors are part of a system specifically designed for placement directly over supports. Strut Installation ABW6-OSS-S INSIDE VIEW Required on expansion joint only 1 2 3 Required on anchored joint only 7 Cable Tray Installation Every second splice must be an expansion joint. For gap setting at expansion joint, refer to NEMA chart on next page. For use with T&B Cable Tray series AH6. Max. load of 80 lb/ft, 20 ft span. Every joint must have a pair of over support splice adaptors (both standard splices and expansion splices) A10

ABW6-OSS-B Beam Installation Expansion over support beam 29 in. SHWCTC, Heavy-Duty hold down clamp (complete with mounting hardware) HGW-SHC, Standard hold down clamp E12-3/8x100EG, 3/8 in. - 16 x 1 in. hex cap screws AC100-3/8EGC, 3/8 in. strut nut NOTE: Every expansion joint requires the use of a bonding jumper such as FBD16-1 (16 in., 600 amps) ABW6-OSS-S Strut Installation Expansion Plate Gap Chart Expansion over support beam 29 in. HGW-SHC, Standard hold down clamp E12-3/8x100EG, 3/8 in. - 16 x 1 in. hex cap screws AC100-3/8EGC, 3/8 in. strut nut NOTE: Every expansion joint requires the use of a bonding jumper such as FBD16-1 (16 in., 600 amps) Metal Temperature at Time for Installation Gap Settings in. (mm) A106