CHEMICAL ENGINEERING 2I03

Similar documents
Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination.

ni.com Sensor Measurement Fundamentals Series

MAE334 - Introduction to Instrumentation and Computers. Final Exam. December 11, 2006

Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination.

Developer Techniques Sessions

MECE 3320 Measurements & Instrumentation. Data Acquisition

5. Transducers Definition and General Concept of Transducer Classification of Transducers

ELG3336 Design of Mechatronics System

MEASUREMENT AND INSTRUMENTATION QUESTION BANK UNIT I INTRODUCTION. Part A

An Instrumentation System

Introduction to Measurement Systems

1. A transducer converts

Biomedical Electrodes, Sensors, and Transducers. Definition of Biomedical Electrodes, Sensors, and Transducers. Electrode: Sensor: Transducer:

Question Bank SENSORS AND INSTRUMENTATION [EE-305/405]

Measurement, Sensors, and Data Acquisition in the Two-Can System

Sensors (Transducer) Introduction By Sintayehu Challa

BME 701 Lecture 1. Measurement and Instrumentation

Section 6 - Electronics

Electronic Instrumentation and Measurements

Analog-Digital Interface

Signal Conditioning Fundamentals for PC-Based Data Acquisition Systems

Lecture 3: Sensors, signals, ADC and DAC

GSM BASED PATIENT MONITORING SYSTEM

Continuous Sensors Accuracy Resolution Repeatability Linearity Precision Range

WebSeminar: Signal Chain Overview

Electronic Systems - B1 23/04/ /04/ SisElnB DDC. Chapter 2

ELECTRONIC SYSTEMS. Introduction. B1 - Sensors and actuators. Introduction

Essential Technologies for Energy Efficiency and Management

Introduction. ELCT903, Sensor Technology Electronics and Electrical Engineering Department 1. Dr.-Eng. Hisham El-Sherif

Section 7 - Measurement of Transient Pressure Pulses

PHYS225 Lecture 22. Electronic Circuits

IT.MLD900 SENSORS AND TRANSDUCERS TRAINER. Signal Conditioning

SENSOR AND MEASUREMENT EXPERIMENTS

Quantity available (A) Quantity required (R) Sl. No. Deficiency (R - A) Description of Equipment


APPLICATION NOTE 695 New ICs Revolutionize The Sensor Interface

Load Cells, LVDTs and Thermocouples

Piezoelectric accelerometer design. Piezoelectric transducers Quartz and piezoceramics Mechanical design Charge amplification Design trade-offs

Kistler portable triaxial Force Plate

CRN: MET-487 Instrumentation and Automatic Control June 28, 2010 August 5, 2010 Professor Paul Lin

EECS 373 Design of Microprocessor-Based Systems

Lock-Ins for electrical measurements

Downloaded from Downloaded from

Chapter 8. Digital and Analog Interfacing Methods

MECHANICAL ENGINEERING SYSTEMS LABORATORY

Vibrating Wire Instrumentation

PVA Sensor Specifications

Ultrasonic. Advantages

M.D. Singh J.G. Joshi MECHATRONICS

Changing the sampling rate

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences

STRAIN, FORCE, PRESSURE, AND FLOW MEASUREMENTS

12/4/ X3 Bridge Amplifier. Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical

UNIT 10 INTRODUCTION TO TRANSDUCERS AND SENSORS

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Butler Technologies. Unit 14, Block G, Maynooth Business Campus, Co. Kildare, Ireland. Calibration Laboratory Registration number: 256C

EEE 432 Measurement and Instrumentation

COURSE INFORMATION. Course Prefix/Number: EET 231. Lecture Hours/Week: 3.0 Lab Hours/Week: 3.0 Credit Hours/Semester: 4.0

09-2 EE 4770 Lecture Transparency. Formatted 12:49, 19 February 1998 from lsli

Butler Technologies. Unit 14, Block G, Maynooth Business Campus, Co. Kildare, Ireland. Calibration Laboratory Registration number: 256C

Sensors and Actuators Introduction to sensors

Chapter 7. Introduction. Analog Signal and Discrete Time Series. Sampling, Digital Devices, and Data Acquisition

ANALOG TO DIGITAL CONVERTER ANALOG INPUT

Analog to Digital Converters

The Norwegian University of Science and Technology ENGLISH. EXAM IN TFY 4185 Measurement Technique/Måleteknikk. 1 Dec 2014 Time: 09:00-13:00

UNIT III Data Acquisition & Microcontroller System. Mr. Manoj Rajale

EECS 373 Design of Microprocessor-Based Systems

XPC10 High temperature miniature pressure sensor

IN COURSE EXAMINATION

InstrumentationTools.com

Anthony Chu. Basic Accelerometer types There are two classes of accelerometer in general: AC-response DC-response

Analog to Digital Conversion

Chapter 7: Instrumentation systems

UNIVERSITY OF NAIROBI COLLEGE OF BIOLOGICAL AND PHYSICAL SCIENCES FACULTY OF SCIENCE SPH 307 INTRODUCTORY ELECTRONICS

Chapter 1 Introduction

CS545 Contents XIV. Components of a Robotic System. Signal Processing. Reading Assignment for Next Class

Silicon-Gate Switching Functions Optimize Data Acquisition Front Ends

3D Distortion Measurement (DIS)

Ch 5 Hardware Components for Automation

Measurement & Control of energy systems. Teppo Myllys National Instruments

Bachelor of Engineering Technology in Control and Automation Systems. Bachelor of Engineering Technology in Electrical Energy Systems

ME 461 Laboratory #5 Characterization and Control of PMDC Motors

Electronic Measurements & Instrumentation. 1. Draw the Maxwell s Bridge Circuit and derives the expression for the unknown element at balance?

Sensors. Chapter 3. Storey: Electrical & Electronic Systems Pearson Education Limited 2004 OHT 3.1

electronics for computer engineering (Sensor) by KrisMT Computer Engineering, ICT, University of Phayao

Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C TP 301

GSM based Patient monitoring system

Pressure Transducer Handbook

Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C

Sensors & transducers

Accelerometer Sensors

SIGNAL RECOVERY: Sensors, Signals, Noise and Information Recovery

ME 365 FINAL EXAM. Monday, April 29, :30 pm-5:30 pm LILY Problem Score

Velocity and Acceleration Measurements

ACTUATORS AND SENSORS. Joint actuating system. Servomotors. Sensors

Troubleshooting accelerometer installations

Patrick N. Laplace, Ph.D. Research Assistant t Professor UNR LSSL Laboratory Manager

Analytical Chemistry II

Industrial Electronics

Temperature References for Highest Accuracy Industrial Thermocouple Measurements

Transcription:

Student Name: Student ID: CHEMICAL ENGINEERING 2I03 DAY CLASS Duration 2 hours McMaster University Practice Exam Dr. M. Thompson The final test includes 60 questions on 12 pages. This test paper must be returned with the answers written on the pages. You are responsible for ensuring that your copy of the paper is complete. Bring any discrepancy to the attention of your invigilator. SPECIAL INSTRUCTIONS 1. McMaster standard calculator (Casio FX-991) ONLY is permitted. 2. Marks for the problems are given (Total of 70 marks) 3. Ensure name and ID number are included above. 4. All work must be done in the provided area for each question. Work done on the back of blank pages in this test or on scrap paper will not be marked. 5. Answers with more than one circled answer will be graded as incorrect. Group One - TRUE / FALSE Questions (1 Mark per question) Circle only the correct response 1. T F A manometer s static sensitivity is proportional to the specific gravity of the manometer fluid 2. T F The LVDT has better position resolution but a smaller range than the linear potentiometer. 3. T F A large thermocouple will reach a steady state value sooner if subjected to a small step input than a large step input. 4. T F A strain gage does not require material deformation to sense force. 5. T F The linear potentiometer is a resistance potentiometer (a rheostat or variable resistor). The voltage output of the potentiometer is proportional to the extension length? Continued on Page 2

6. T F Thermistors are normally not as sensitive as RTDs, but are much less expensive to manufacture. 7. T F Quantization error can be reduced by signal amplification. 8. T F FSO stands for fixed standardized output. 9. T F The linear potentiometer is a resistance potentiometer (a rheostat or variable resistor). Is the voltage output of the potentiometer proportional to the extension length? 10. T F A proving ring is used to calibrate load cells. Group Two Multiple Choice Questions (1 Mark per question) Circle the letter corresponding to the most appropriate answer 16. A thermistor: a) requires a constant cold junction to remain calibrated. b) changes resistance in proportion to changes in temperature. c) outputs a small voltage which is proportional to the temperature. d) requires a voltage source to function. e) both b) and d) are correct 17. The quantization size of an ADC is related to: a) the speed of the A/D conversion. b) the number of bits of the A/D converter. c) the amplitude of the input signal relative to the full range of the A/D converter. d) all of the above are correct. e) only B and C are correct. 18. Which of the following properties are generally desirable in a transducer? a) Large time constant b) Low natural frequency c) Linearity d) A, B & C are all desirable e) B & C are both desirable

19. Which of the following temperature sensors is the least expensive to purchase and implement? a) Thermocouple b) Thermistor c) Infra Red Detector d) RTD 20. If the Nyquist sampling criteria was satisfied for an input signal with a frequency of 1kHz, what was the sampling rate? a) 1 khz b) 200 khz c) 2 khz d) None of the above 21. What kind of elastic element was used in a pressure transducer? a) a foil bonded to the diaphragm b) a stretched wire c) a piezoresistive semiconductor d) none of the above 22. The number of different values that can be discretized by a 12 bit ADC is: a) 4096 b) 2048 c) 1024 d) 256 e) 512 23. If a 30 Hz signal for the measurement is being deteriorated by the noise of nearby electrical devices, these errors can be reduced by: a) shielding the cables b) using a notch filter c) Using a band pass filter d) both a) and c) are correct 24. Aliasing describes the phenomena: a) in which signal frequency appears higher than the actual value due to inadequate sampling rate.

b) in which signal frequency appears lower than the actual value due to inadequate sampling rate. c) in which signal waveform appears distorted. 25. Which of the following never depends on the sampling rate? a) Frequency of the sampled signal b) Magnitude of the sampled signal c) Nyquist frequency of the input signal d) Shape of the sampled signal 26. The plot of magnitude ratio vs frequency at right is typical of a: a) low pass filter b) high pass filter c) band pass filter d) notch filter 27. A transducer being used to measure vibrations with a frequency range of 10-500 Hz is very sensitive to noise from electrical motors running at 500-1000 RPM. The effect of the noise can be minimized by passing the output through a: a) Low pass filter b) high pass filter c) notch filter d) bandpass filter 28. The quantization error in a data set could be reduced by first a) increasing the speed of the electronics. b) increasing the number of bits in the ADC

c) amplifying the input signal d) both B and C are correct. e) A, B and C are all correct. 29. If the 60 Hz signal from nearby electrical devices is creating measurement system interference errors these errors can be reduced by: a) shielding the cables b) using a notch filter c) Using a band pass filter d) Both a & b e) Both a & c 30. The aliasing frequency that results from sampling a signal of 60 Hz at a sample rate of 90 Hz is: (use the folding diagram at the end of this test to help) a) 30 Hz b) 59.9 Hz c) 60.3 Hz d) 79.8 Hz e) 90 Hz (more to come...31 50) Group Three Short Answer Questions [Any sentences follow the number indicated by the question will NOT be considered in the grading for that question] 51. List four reference pressure instruments useful in the calibration of pressure sensors. Explain in one sentence. (2 Marks) McLeod Barometer Manometer Deadweight tester 52. In one sentence, define resolution of quantization. (2 Marks) Q = E FSR / (A/D bits) 53. In one sentence, state four categories of chemical sensors (2 Marks)

Electrochemical Calorimeter Thermometric Optical biological 54. Explain in one sentence the operational principle of sample and hold. (2 Marks) Capacitor holds the voltage signal till its value is manipulated for less sophisticated ADC systems, like a handheld unit. 55. Name the two disadvantages of using flow meters based on moving mechanical parts like a paddle or gear. Two sentences maximum. (2 Marks) impairs flow area, directly in contact with fluid THE END