XDSL/TELEPHONE CABLE MEASUREMENT Phenix 10056 Cmplete Slutin fr xdsl Cables Cat 3, 4, 5 and 5e DESCRIPTION Custmer requirements can vary cnsiderably in terms f size and design f cnnecting frames depending n hw many pairs need t be hked up t the frame simultaneusly. The Phenix 10056 system allws yu t hk up a maximum f 56 pairs. Thanks t the "OptiTest" sftware mdule (an element f the CIQ family) supplied with it, peratrs can wrk quickly and efficiently. OptiTest als allws analysis f parameter measurements fr prcess cntrl, traceability r any ther functins requiring statistical infrmatin.. KEY FEATURES Fast and cmpliant The fastest measurement system n the market Cmpliant t all majr natinal standards fr telephne and xdsl cables Easy t use N cable preparatin behalf f self-cutting knives Intuitive sftware Accurate and certifieds Quality inspectin, with very high accuracy Check against certified ISO 17025 standards Add-n LCL/LCTL parameters EMC parameters (TI, AS, AC)
Phenix 10056 TECHNICAL SPECIFICATIONS All standard lw frequency and high frequency parameters available (Resistance, Parameters Capacitance, Insertin Lss, Impedance, NEXT, FEXT, ) Perfrms all electrical tests n cables respnding t: Standards ANSI/TIA-568-C.2 fr Categry 3 and 5e IEC 61156-5/-6 fr Categry 5e 2x 56 pairs cnnecting frames fr LF & HF measurements up t 100MHz 1 state-f-the-art cmputer with a 17 clur mnitr Cmpnents Operating Windws system 1 license OptiTest, AESA measurement and result management sftware Pwer supplies, interfaces, cnnecting cables and measurement accessries Supply Vltage 100-240 VAC / 50-60 Hz, Cnsumptin: 600 W withut printer, 1000 W with printer Article N: 10.1056.0001.0 HIGH FREQUENCY ACCURACY 100 khz - 30 MHz 30 MHz - 60 MHz 60 MHz - 100 MHz Attenuatin (crrected at 20 C) -80 t -50 db ± 2 db ± 2 db ± 3 db -50 t -25 db ± 0.8 db ± 1 db ± 1.5 db -25 t -10 db ± 0.3 db ± 0.5 db ± 1 db -10 t 0 db ± 0.2 db ± 0.4 db ± 0.8 db Near-End Crsstalk NEXT & Far-End Crsstalk FEXT -90 t -50 db ± 2 db ± 2 db ± 2 db -50 t -30 db ± 1 db ± 1 db ± 1 db -30 t -20 db ± 0.5 db ± 0.5 db ± 0.5 db Impedance 70 Ω - 90 Ω ± 2 Ω ± 2 Ω ± 2 Ω 90 Ω - 110 Ω ± 1.5 Ω ± 1.5 Ω ± 1.5 Ω COMPONENTS We deliver: Integrated equipment External Display, keybard and muse AVAILABLE OPTIONS The equipment can be cmpleted with: LCL/LCTL family parameters EMC parameters (Transfer Impedance (TI), Screening Attenuatin (AS)) 9800 HF standards (50 SMA) 9000 LF standards Printer Maintenance cntract AESA prpses ther specific equipment fr high frequency measurement. www.aesa-crtailld.cm 2018 AESA SA. All rights reserved Page 2 f 9 aesa@aesa-crtailld.cm Phne: +41 32 841 5177
Phenix 10056 KEY BENEFITS USER-FRIENDLY Optitest sftware is multilingual Direct results withut pst calculatin Calibratin managed/saved by cmputer Test rders library ACCURATE The equipment is checked against traceable calibratin standards accrding ISO/IEC 17025 The risk f human errr is reduced t its minimum SMART All data (results and cnditins) are saved in its internal PC Reprts can be printed Data can be exprted thrugh the LAN in an ASCII r XLS file www.aesa-crtailld.cm 2018 AESA SA. All rights reserved Page 3 f 9
Phenix 10056 LOW FREQUENCY PARAMETERS SPECIFICATIONS The lw frequency parameters measuring technlgy prvides a self-calibratin. It is designed t test up t 4 pairs r 2 quads. Different measuring frequencies are integrated in the capacitance bridge. They can be used depending n the length f the cable Descriptin Cnductr resistance Designatin fr pairs Ra, Rb Designatin fr quads Lp resistance R R1, R2 Resistance unbalance DR Accuracy Scale Ra, Rb Rc, Rd 0,1% + 10 m 0-19,999 k DR1, DR2, DR3 Capacitance C C1, C2, C3 Capacitance unbalance Capacitance unbalance t grund K Ei, Ea, E K1 K12 Ei1-Ei3 Ea1-Ea3 E1-E3 Cmputed 0,25% 10pF at 800 Hz 0,25% 10pF at 125 Hz 0,25% 50pF at 12,5Hz 1% 6pF at 800 Hz 1% 3pF at 125 Hz 1% 30pF at 12,5 Hz %, 0 2'000nF Calculated parameters at 800Hz (1'000Hz) Attenuatin Phase Characteristic Impedance Velcity f prpagatin (VOP) Crsstalk Statistical parameters Maximum and minimum measured values Upper quality factr Abslute minimum measured value Lwer quality factr Average value RC prduct Quadratic average Standard deviatin RC Standard deviatin Variance KEY BENEFITS 1. Technical hardware features - Test heads with "pen/shrt/lad" facility allwing a fully autmatic calibratin prcedure - N ther calibratin is required, which speeds up the measurements - Fr a fast cable cnnectin, the standard cnnecting frames are equipped with self-cutting knives designed fr cpper diameters frm 0.35mm t 0.9mm. Special knives are available n request fr diameter up t 1.5mm - N mvable parts fr maximum measurement speed, accuracy and reliability - Mechanical design studied t facilitate maintenance and servicing peratins www.aesa-crtailld.cm 2018 AESA SA. All rights reserved Page 4 f 9
Phenix 10056 2. Main sftware features The OptiTest sftware is a stand-alne applicatin specially designed fr data capture with autmatic testing equipment. This mdule is a part f the AESA s Quality Management System CIQ 3.0 specially designed accrding t the needs f the cable manufacturing industry. - The sftware has been develped in the Micrsft Windws envirnment and cmplies with the Windws features. - All data gathered with OptiTest can be used fr further statistical evaluatins and cmbined with ther measurements gathered during the cmplete manufacturing prcess, frm incming gd inspectin until t the dispatch f the finished prduct. - N special HF r LF knwledge required, thus ideal fr shp flr integratin. - Full autmatic measurements. - The measurements can be perfrmed in the sweep mde and/r by using frequency tables. - Open chice fr start/stp frequencies and number f pints (fr HF sweep measurements, the test system allws t enter an unlimited number f measurement pints, which is nt limited by the specified number f pints as referred by the used VNA analyzer itself). - Chice f lgarithmic r linear scales. - Self-cnfigurable reprts. - Fully autmatic calibratin management including autmated calibratin prcedure. - Pssibility t create an unlimited number f cable specificatins and test sequences. These test specificatins will be stred with an individual custmised name and are easily retrievable. - Pssibility t generate cmplex limit curves. Mst f the limits and frmulas recmmended by the internatinal standards are integrated. Their variables are prgrammable t enable the preparatin f special specificatins. I. OptiTest facilitates the tasks itemised belw: a. Creatin and administratin f test specificatins b. Perfrmance f tests c. Reprt generatin after testing d. Basic statistic evaluatin II. Test Plan Creatin: a. A wide range f measurement mdes are available as ptins, such as HF Sweep, HF Sweep(Alien), HF Cax-50, HF Cax-75, HF fixed frequency, LF single cres, LF pairs, LF triples, LF quads, LCL, LCTL, TCL, b. TCTL, TI, AS, wrst case summaries fr HF-Sweep / LF / HF discrete frequencies, inductance, cnductance and high vltage. c. Reprt generatin is very easy. If set by default, a highly cmprehensive reprt is generated, cntaining a limit case cmpilatin with graphics and fr each measuring blck a separate summary with related graphics. www.aesa-crtailld.cm 2018 AESA SA. All rights reserved Page 5 f 9
Phenix 10056 III. Dcument: a. Reprts: OptiTest ffers varius reprt ptins such as: - Test certificates fr the custmer - Creating (cntrl) quality charts - Graphical HF evaluatins The results may be printed, stred as PDF files, r sent as emails. It is als pssible t create data files fr Office prducts such as Micrsft Excel. b. Evaluatin: All data are available fr evaluatin at any time. Thus, all test data f a cable can be cllectively evaluated and printed. Sme examples f hw t perfrm evaluatins are: - Sample list srted by test rder - Search with pre-defined r custmized filters (e.g. searching fr the last 20 samples by cable number, date, certain characteristics) - Free search thrugh the data pl with user-specific search criteria Filters and search criteria nrmally generate sample lists which facilitate multiple further actins as: - Display and prcess measured values - Print reprts and labels - Generate quality charts (statistics) Examples f test and statistical reprts with AESA Optitest c. Archiving: Windws backup functin used fr archiving the data. www.aesa-crtailld.cm 2018 AESA SA. All rights reserved Page 6 f 9
Phenix 10056 d. Statistics: Filtering tl: Select a grup f measurements accrding t varius criteria such as: - Cable specificatin - Cable structure - Prductin perid - Prductin line, test statin - Etc Fllwing the measurements management, this pwerful tl allws generating many types f statistics. Wrst case values fr a pair r a cable - Pair identificatin with extreme values - Min, max, average values - Standard deviatin, quality factr, RMS values - Etc These statistical means are calculated fr all measured LF (and partly HF) parameters e. Graphical presentatin: - Statistical distributin (Gauss type curve) - Evlutin and parameter survey in functin f the time - Measurements repartitin in a defined time perid t determine the testing lad www.aesa-crtailld.cm 2018 AESA SA. All rights reserved Page 7 f 9
Phenix 10056 Optins 1. Netwrk Analyzer - Agilent type E5061B 2 prts (100 khz 1.5 GHz) Article N: 51.0001.0045.0 Other types can be prpsed upn request. 2. Set f 5 standards (resistance & capacitance) type AESA 9000 Article N: 45.9000.0001.0 Cmplete ISO 17025 certified LF calibratin standards. The kit f certified LF calibratin standards is cmpsed f: - Standard type 9001 C1,2 with 19,20 nf 0,1 % 30 ppm/ C - Standard type 9002 C1,2 with 192,0 nf 0,1 % 30 ppm/ C - Standard type 9003 C3 with 16,00 nf 0,1 % 30 ppm/ C K1, K2, K3 with 16000 pf 0,1 % 30 ppm/ C - Standard type 9004 E1, E2, E3 with 12000 pf 0,1 % 30 ppm/ C - Standard type 9005 RA, RD with192 RB, RC with 1920 0,01 % 2 ppm/ C 0,01 % 2 ppm/ C 3. Set f HF calibratin standards (attenuatrs and lads) type AESA 9800 Article N: 45.9800.0001.0 With each sld measuring system, AESA delivers a "daily" calibratin kit t create the different calibratin files necessary t measure LAN cables. These easy-t-use standards have been develped in the symmetrical way t get the maximum accuracy. Unfrtunately, these "daily" standards cannt be referenced as primary standards. But AESA has develped its HF technlgy by using hi-tech strategic cmpnents. These miniaturized resistrs are srted and guaranteed up t 3GHz. Tlerance: 1% (50 ppm/deg.) fr values between 50 and 200Ω. www.aesa-crtailld.cm 2018 AESA SA. All rights reserved Page 8 f 9
Phenix 10056 During a quality cntrl calibratin, the symmetric elements have t be replaced by 50Ω caxial standards which are certified. With an apprpriate set f terminatins and attenuatrs, it is pssible t prve within defined tlerances that the testing system (netwrk analyzer + HF multiplexer + cnnecting frame) is measuring crrectly. It is als pssible t prve that the calibratin dne fr the measurement f LAN cables has been dne crrectly. The kit f certified HF calibratin standards is cmpsed f: - 2 attenuatin references 3dB type 9801-2 attenuatin references 6dB type 9802-2 attenuatin references 10dB type 9803-2 attenuatin references 20dB type 9804-2 attenuatin references 30dB type 9805-2 x 50Ω terminatins - 2 special cnnectrs fr the terminatins - 4 HF cnnecting cables fr the attenuatin - 1 set f miscellaneus HF material 4. Caxial ptins Specific utput (N-cnnectrs) fr cax measurement. The slutin includes the equipment mdificatin and the related sftware mdule. - 50 hms caxial ptin Article N: 50.0001.0031.0-50 and 75 hms caxial ptin Article N: 50.0001.0029.0 5. Spare Parts AESA recmmends fllwing set f spare parts fr an peratin safety f tw years: Phenix Type Mini KIt Full KIt 1 CKE measuring bridge type KM 1 R measuring bridge type RM 1 LF relay matrix bard type AZU 1 CPU bard 2 test heads (4 if tw different cnnecting frames) 2 HF relays (3 if tw different cnnecting frames) 1 cntrl bards set 1 set f HF cable 1 set f different mechanical and electrnic hardware Article N 50.0900.0003.0 50.0900.0002.0 www.aesa-crtailld.cm 2018 AESA SA. All rights reserved Page 9 f 9