Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Similar documents
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Parameterisable damper actuator in the

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing

Functional data Factory settings Variable Settings

Overview of types. Technical data

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Power consumption Operation At rest Wire sizing

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Technical data sheet. Technical data. Safety notes

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Brief description. Type overview

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Technical data. Safety notes

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

DN [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

Brief description. VAV-Compact MP en-gb Changes reserved 1. Application. Pressure measurement. Actuator

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Image. Installation VAV-Universal Retrofit-Set. General Information. Safety notes

Installation of VAV-Compact Retrofit with ZDMS-..

GMU24. Technical data. Dimensions [mm] For operation of air control dampers in HVAC system Torque: 40Nm Nominal voltage: AC/DC 24V Control: Open/Close

Rp [ ] [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Type overview. Technical data

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

Non-Spring Return EconoDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

Configured air damper actuators 6FU11xx-xDxxx-xxxx

LM Series Direct Coupled Actuator

Rotary gear motor series AG8...

AC 01.2 HART Technical data Actuator controls

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

1-phase AC current voltages/frequencies Volt Volt

Adaptive control system for duct and room pressure applications. Table of Contents

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AC 01.2 Modbus TCP/IP

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

Non-Spring Return DuraDrive Modulating Actuator

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

Technical Instructions Document No EA GQD June 23, OpenAir

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Rotary actuators for ball valves

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

Output Signal Active Temperature. Electrical data Power Supply DC V, ±10%, 0.5 W

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

Type 3374 Electric Actuator

VAV solutions for comfort applications

Actuator for modulating control AME 435

MODEL: MRP6. Final Control Elements

Electromotoric actuators for stroke valves

Explosion proof rotary actuator - On/Off or programmable regulating actuator

F6 Series 2-Way, Victaulic Butterfly Valve

Electronic Circuit Protector ESX10-T

..-MF /..-MP /..-MFT(2) /..-MOD /..LON..-MF /..-MP /..-MFT(2) /..-MOD /..LON

Electric Actuator. of innovated design. Introducing KIMAX CONTROLS INC. > Patented switch of manual & Motor operation. Clutchless manualoverride.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electromotoric actuators

EY-EM 527: Remote I/O module, ecolink527

Electronic Circuit Protector ESX10

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Specification GRUNER YSP 227C

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

Electronic Air / Fuel Ratio Control System

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Power supply CP-E 24/2.5

Transcription:

echnical data sheet GK24G-MF Parameterisable SuperCap damper actuator with emergency control function and extended functionalities in the IP66 protective housing for adjusting dampers in technical building installations and in laboratories Air damper size up to approx. 8 m² Nominal torque 4 Nm Nominal voltage AC/DC 24 V Control modulating DC ()2... V Variable Position feedback DC 2... V Variable Design life SuperCaps: 5 years Optimum weather protection for use outdoors (for use in ambient temperatures up to 4 C, there is a separate actuator available with built-in heater ex works) echnical data Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency 5/6 Hz Nominal voltage range AC 9.2...28.8 V / DC 2.6...28.8 V Power consumption in operation W Power consumption in rest position 3 W Power consumption for wire sizing 2 VA Power consumption for wire sizing note Imax 2 A @ 5 ms Connection supply / control Cable m, 4 x.75 mm² (halogen-free) Parallel operation es (note the performance data) Functional data orque motor Min. 4 Nm Positioning signal DC... V Positioning signal note Input impedance kω Control signal variable Open-close 3-point (AC only) Modulating (DC...32 V) Operating range DC 2... V Operating range variable Start point DC.5...3 V End point DC 2.5...32 V Position feedback DC 2... V Position feedback note Max..5 ma Position feedback variable Start point DC.5...8 V End point DC 2.5... V Setting emergency setting position (POP)...%, adjustable in increments of % (POP rotary knob on corresponds to left end stop) Setting emergency setting position (POP)...%, adjustable variable Bridging time (PF) 2 s Bridging time (PF) variable... s Position accuracy ±5% Direction of motion motor selectable with switch / Direction of motion note = V: At switch position (ccw rotation) / (cw rotation) Direction of motion variable electronically reversible Direction of motion emergency control selectable with switch...% function Manual override with push-button (under protective housing) Angle of rotation Max. 95 Angle of rotation note can be limited on both sides with adjustable mechanical end stops Running time motor 5 s / 9 Motor running time variable 9...5 s Running time emergency control position 35 s / 9 Running time emergency setting position <35 s @...5 C note www.belimo.eu GK24G-MF en-gb 27-- subject to changes

modulating, AC/DC 24 V, 4 Nm echnical data Functional data Adaption setting range manual Adaption setting range variable No action Adaption when switched on Adaption after pushing the gear disengagement button Override control MAX (maximum position) = % MIN (minimum position) = % ZS (intermediate position, AC only) = 5% Override control variable MAX = (MIN + 32%)...% MIN = %...(MAX 32%) ZS = MIN...MAX Sound power level motor 52 db(a) Sound power level emergency control 6 db(a) position Spindle driver niversal spindle clamp 4...26.7 mm Position indication Mechanical Safety Protection class IEC/EN III Safety Extra-Low Voltage (SELV) Protection class L L Class 2 Supply Degree of protection IEC/EN IP66 Degree of protection NEMA/L NEMA 4, L Enclosure ype 4 EMC CE according to 24/3/E Certification IEC/EN IEC/EN 673- and IEC/EN 673-2-4 Certification L clus according to L 673-A, L 673-2- 4 and CAN/CSA E673-:2 Mode of operation ype.aa Rated impulse voltage supply / control.8 kv Control pollution degree 4 Ambient temperature -3...5 C Ambient temperature note -4...5 C for actuator with integrated heating Non-operating temperature -4...8 C Ambient humidity % r.h. Maintenance Maintenance-free Weight Weight 4.5 kg erms Abbreviations POP = Power off position / emergency setting position PF = Power fail delay time / bridging time Safety notes! he device must not be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. Junction boxes must at least correspond with enclosure IP degree of protection! he cover of the protective housing may be opened for adjustment and servicing. When it is closed afterwards, the housing must seal tight (see installation instructions). he device may only be opened in the manufacturer s factory. It does not contain any parts that can be replaced or repaired by the user. he cables must not be removed from the device installed in the interior. o calculate the torque required, the specifications supplied by the damper manufacturers concerning the cross-section, the design, the installation site and the ventilation conditions must be observed. he device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed. he actuator is not designed for applications where chemical influences (gases, fluids) are present or for utilisation in corrosive environments in general. he actuator may not be used in plenary applications (e.g. suspended ceilings or raised floors). 2 GK24G-MF en-gb 27-- subject to changes www.belimo.eu

Safety notes modulating, AC/DC 24 V, 4 Nm he materials used may be subjected to external influences (temperature, pressure, construction fastening, effect of chemical substances, etc.), which cannot be simulated in laboratory tests or field trials. In case of doubt, we definitely recommend that you carry out a test. his information does not imply any legal entitlement. Belimo will not be held liable and will provide no warranty. Self adaption is necessary when the system is commissioned and after each adjustment of the angle of rotation (press the adaption push-button once). If cables which are not authorised for L (NEMA) ype 4 applications are guided out of the unit, then flexible metallic cable conduits or suitable threaded cable conduits of equal value are to be used. Product features Fields of application Mode of operation Pre-charging time (start up) he actuator is particularly suitable for utilisation in outdoor applications and is protected against the following weather conditions: - V radiation - rain / snow - dirt / dust - Humidity - Changing atmosphere / frequent and severe temperature fluctuations (recommendation: use the actuator with integrated factory-installed heating which can be ordered separately to prevent internal condensation) he actuator moves the damper to the desired operating position at the same time as the integrated capacitors are charged. Interrupting the supply voltage causes the damper to be rotated back into the emergency setting position (POP) by means of stored electrical energy. he actuator is connected with a standard modulating signal of DC...V and drives to the position defined by the positioning signal. Measuring voltage serves for the electrical display of the damper position...% and as slave control signal for other actuators. he capacitor actuators require a pre-charging time. his time is used for charging the capacitors up to a usable voltage level. his ensures that, in the event of an electricity interruption, the actuator can move at any time from its current position into the preset emergency setting position (POP). he duration of the pre-charging time depends mainly on following factors: Duration of the electricity interruption PF delay time (bridging time) ypical pre-charging time 3 [s] 25 PF [s] s 3 [s] 25 2 5s 2s s 2 5 5 5 5 2 4 6 8 [d] 2 [d] = Electricity interruption in days [s] = Pre-charging time in seconds PF[s] = Bridging time Calculation example: Given an electricity interruption of 3 days and a bridging time (PF) set at 5 s, the actuator requires a pre-charging time of 4 s after the electricity has been reconnected (see graphic). PF [s] [d] 2 7 5 8 5 9 2 6 9 6 2 5 8 3 8 22 2 5 7 22 26 [s] www.belimo.eu GK24G-MF en-gb 27-- subject to changes 3

modulating, AC/DC 24 V, 4 Nm Product features Delivery condition (capacitors) Parameterisable actuators Simple direct mounting Manual override Adjustable angle of rotation High functional reliability Home position Direction of rotation switch Adaption and synchronisation Emergency setting position (POP) rotary knob he actuator is completely discharged after delivery from the factory, which is why the actuator requires approximately 2 s pre-charging time before initial commissioning in order to bring the capacitors up to the required voltage level. he factory settings cover the most common applications. Single parameters can be modified with the Belimo Service ools MF-P or ZH E. Simple direct mounting on the damper spindle with an universal spindle clamp, supplied with an anti-rotation device to prevent the actuator from rotating. Manual control with push-button possible - temporary. he gear is disengaged and the actuator decoupled for as long as the button is pressed. he housing cover must be removed for manual override. Adjustable angle of rotation with mechanical end stops. he actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached. he first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out a synchronisation. he synchronisation is in the home position (%). he actuator then moves into the position defined by the positioning signal. When actuated, the direction of rotation switch changes the running direction in normal operation. he direction of rotation switch has no influence on the emergency setting position (POP) which has been set. An adaption can be triggered manually by pressing the Adaption button or with the PC-ool. Both mechanical end stops are detected during the adaption (entire setting range). A range of settings can be adapted using the PC-ool (see MF-P documentation) he «Emergency setting position» rotary knob can be used to adjust the desired emergency setting position (POP) between and % in % increments. he rotary knob refers only to the adapted angle of rotation range between 3 and 95. No set Min or Max values are observed. In the event of a electricity interruption, the actuator will move into the selected emergency setting position (POP), taking into account the bridging time that has been set. Settings: he rotary knob must be set to the «ool» position for retroactive settings of the emergency setting position (POP) with the Belimo service tool MF-P. Once the rotary knob is set back to the range %, the manually set value will have positioning authority. Bridging time Electricity interruptions can be bridged up to a maximum of s. In the event of an electricity interruption, the actuator will remain stationary in accordance with the set bridging time. If the electricity interruption is greater than the set bridging time, then the actuator will move into the selected emergency setting position (POP). he bridging time set ex-works is 2 s. his can be modified on site in operation with the use of the Belimo service tool MF-P. Settings: he rotary knob must not be set to the ool position! For retroactive adjustments of the bridging time with the Belimo service tool MF-P or with the ZH E adjustment and diagnostic device only the values need to be entered. 4 GK24G-MF en-gb 27-- subject to changes www.belimo.eu

modulating, AC/DC 24 V, 4 Nm Accessories Description Electrical accessories Auxiliary switch, add-on, x SPD SA Auxiliary switch, add-on, 2 x SPD S2A Feedback potentiometer 4 Ohm, add-on P4A Feedback potentiometer 4 Ohm, add-on, grey P4A GR Feedback potentiometer 2 Ohm, add-on P2A Feedback potentiometer 5 Ohm, add-on P5A Feedback potentiometer 5 Ohm, add-on, grey P5A GR Feedback potentiometer kohm, add-on PA Feedback potentiometer kohm, add-on, grey PA GR Feedback potentiometer 2.8 kohm, add-on P28A Feedback potentiometer 2.8 kohm, add-on, grey P28A GR Feedback potentiometer 5 kohm, add-on P5A Feedback potentiometer 5 kohm, add-on, grey P5A GR Feedback potentiometer kohm, add-on PA Feedback potentiometer kohm, add-on, grey PA GR Adapter for auxiliary switch and feedback potentiometer Z-SPA* Signal converter voltage/current, supply AC/DC 24V Z-IC Digital position indicator for front-panel mounting,...99%, front mass ZAD24 72 x 72 mm Range controller for wall mounting, adjustable electron. Min./max. SBG24 angle of rotation limitation Positioner for wall mounting, range...% SGA24 Positioner in a conduit box, range...% SGE24 Positioner for front-panel mounting, range...% SGF24 Positioner for wall mounting, range...% CRP24-B Connection cable 5 m, A+B: RJ2 6/6, o ZH/ZIP-SB-MP ZK-GEN Connection cable 5 m, A: RJ 6/4, B: Free wire end, o ZH/ZIP- SB-MP ZK2-GEN Description Mechanical accessories Cable gland, for cable diameter 4- mm Z-KB-PG ype ype Description Service ools Service tool for parametrisable and communicative Belimo actuators / VAV controller and HVAC performance devices Belimo PC-ool, software for adjustments and diagnostics Adapter to Service ool ZH ype ZH E MF-P MF-C Electrical installation! Notes Connection via safety isolating transformer. Parallel connection of other actuators possible. Observe the performance data. www.belimo.eu GK24G-MF en-gb 27-- subject to changes 5

modulating, AC/DC 24 V, 4 Nm Electrical installation Wiring diagrams AC/DC 24 V, modulating DC ()2 V DC 2 V Cable colours: = black 2 = red 3 = white 5 = orange Parallel operation 2 X Notes A maximum of eight actuators can be connected in parallel. Parallel operation is permitted only on non-connected axes. Do not fail to observe performance data with parallel operation. Wiring diagram piggyback operation (mechanically coupled actuators) Master Slave Notes A maximum of two actuators can be connected in Master-Slave operation. he Master-Slave operation is permitted only on one fixed spindle or on two mechanically coupled spindles. he programming of the Master actuator is adopted by the Slave actuator. Signal cable lengths L C L 2 L L 2 tot / A L tot = L + L 2 AC DC.75 mm 2 3 m 5 m. mm 2 4 m 8 m.5 mm 2 7 m 2 m 2.5 mm 2 m 2 m A = actuator C = control unit L = actuator connecting cable L2 = customer cable Ltot = maximum signal cable length Note: In the event of several actuators switched in parallel, the maximum signal cable length is to be divided by the number of actuators. 6 GK24G-MF en-gb 27-- subject to changes www.belimo.eu

modulating, AC/DC 24 V, 4 Nm Electrical installation N L AC 23 V AC 24 V C A = actuator C = control unit L = actuator connecting cable L A Note: If supply and data line are handled separately, then no special limitations apply for the installation. Functions Functions with basic values (conventional mode) Override control with AC 24 V with relay contacts Override control with AC 24 V with rotary switch a b c (DC... V) % ZS 5% % (DC... V) e.g. N 47 % ZS 5% a b c e.g. N 47 % Remote control...% with positioner SG.. Minimum limit with positioner SG.. Z 2 3 4 SGA24 SGF24 SGE24 Z 2 3 4 SGA24 SGF24 SGE24 [V] (DC... V) min [%] Position indication Control with 4...2 ma via external resistor ZAD24 2 3 4 ) 5 Ω ( ) (+) 4 2 ma DC 2 V () Adapting the direction of rotation Caution: he operating range must be set to DC 2... V. he 5 Ω resistor converts the 4...2 ma current signal to a voltage signal DC 2... V www.belimo.eu GK24G-MF en-gb 27-- subject to changes 7

modulating, AC/DC 24 V, 4 Nm Functions Functional check Procedure. Connect 24V to connections and 2 2. Disconnect connection 3: with direction of rotation : Actuator rotates to the left with direction of rotation : Actuator rotates to the right 3. Short-circuit connections 2 and 3: Actuator runs in opposite direction Functions for actuators with specific parameters (Parametrisation with PC-ool necessary) Override control and limiting with AC 24 V with relay contacts Override control and limiting with AC 24 V with rotary switch a b c d e (DC... V) Close ) MIN ZS MAX Open (DC... V) e.g. N 47 Close ) MIN ZS MAX Open a b c d e e.g. N 47 ) Caution: his function is only guaranteed if the start point of the operating range is defined as min..5 V. Control open-close Control 3-point a b e.g. N 47 8 GK24G-MF en-gb 27-- subject to changes www.belimo.eu

modulating, AC/DC 24 V, 4 Nm Operating controls and indicators B 2 Direction of rotation switch 2 Cover, POP button 3 POP button A 7 5. OOL.5 3 POP.9 8 9 Status Power Adaption 4 4 Scale for manual adjustment 5 Position for adjustment with tool 6 ool socket 7 Disengagement button 6 LED displays 8 yellow 9 green Meaning / function Off On Operation OK / without fault Off Flashing POP function active On Off Fault Off Off Not in operation On On Adaptation procedure running Flashing On Communication with programming tool Setting emergency setting position (POP) 9 Press button: riggers angle of rotation adaption, followed by standard operation.5..9 OOL.5..9 OOL. OOL.5.9 POP %.... OOL.5.9 POP > PC-ool ZH www.belimo.eu GK24G-MF en-gb 27-- subject to changes 9

modulating, AC/DC 24 V, 4 Nm Service Service ools connection he actuator can be parameterised by ZH E via the service socket. For an extended parameterisation the PC tool can be connected. Connection ZH E / PC-ool AC 24 V DC 24 V MP SB ZH E i esc OK BELIMO PC-ool SB Dimensions [mm] Spindle length Dimensional drawings L - 6...75 63 4... 22 mm 2... 8 mm 2 9 57 86 238 35 22... 26.7 mm 2... 8 mm 72 33 GK24G-MF en-gb 27-- subject to changes www.belimo.eu