1 Electronic Circuit Protector ESX0 Description Electronic circuit protector type ESX0 is designed to ensure selective disconnection of DC 24 V load systems. DC 24 V power supplies, which are widely used in industry today, will shut down the output in the event of an overload with the result that one faulty load in the system can lead to complete disconnection of all loads. As well as an unidentified failure this also means stoppage of the whole system. Through selective disconnection the ESX0 responds much faster to overload or short circuit conditions than the switch-mode power supply. This is achieved by active current limitation. The ESX0 limits the highest possible current to values between.3 to.8 times the selected rated current of the circuit protector. Thus it is possible to switch on capacitive loads of up to 75,000 μf lamp loads, but they are disconnected only in the event of an overload or short circuit. For optimal alignment with the characteristics of the application the current rating of the ESX0 can be selected in fixed values from 0.5 A...2 A. Failure and status indication are provided by a multicolour LED and an integral short-circuit-proof status output or a potential-free signal contact. The ESX0, with a width of only 2.5 mm, can be plugged into the E-T-A power distribution socket Module 7plus ensuring ease of installation and saving space in control cabinets. Upon detection of overload or short circuit in the load circuit, the MOSFET of the load output will be blocked to interrupt the current flow. The MOSFET and the load circuit may be re-activated via the remote electronic reset input or manually by means of the ON/OFF button. When starting up the system, the load circuit may also be manually disconnected. Features Selective load protection, electronic trip characteristics. Active current limitation for safe connection of capacitive loads up to 75,000 μf and on overload/short circuit. Current ratings 0.5 A...2 A. Reliable overload disconnection with. x I N plus, even with long load lines or small cable cross sections (see table 3). Manual ON/OFF button (S). Clear status and failure indication through LED, status output SF or Si contact F. Electronic reset input (option). Integral fail-safe element. Width per unit only 2.5 mm. Plug-in mounting utilising power distribution system Module 7plus or SVSxx optionally (see product group Power distribution systems) Additional versions with ATEX approval available. Marking: II 3G Ex na IIB T4 Gc X ESX0-...-E Please observe separate operating instructions: ESX0 Technical data (T ambient = 25 C, operating voltage U S = DC 24 V) Operating data Operating voltage U S DC 24 V ( V) Current rating I N fixed current ratings: 0.5 A, A, 2 A, 3 A, 4 A, A, 8 A, 0 A, 2 A Closed current I 0 ON condition: typically ma depending on signal output Status indication multicolour LED: by means of GEN: unit is ON, power-mosfet is switched on - status output SF ON, supplies +DC 24 V ORANGE: in the event of overload or short circuit until electronic disconnection D: - unit electronically disconnected - load circuit/power-mosfet OFF OFF: - manually switched off (S = OFF) or device is dead - undervoltage (U S < 8 V) - after switch-on till the end of the delay period status output SF (option) potential-free signal contact F (option) ON/OFF/ condition of switch S Load circuit Load output Power-MOSFET switching output (high side switch) Overload disconnection typically. x I N ( x I N ) Short-circuit current I K active current limitation (see table ) Trip time see time/current characteristics for electronic disconnection typically 3 s at I Load >. x I N typically 3 s...00 ms at I Load >.8 x I N (or.5 x I N /.3 x I N ) Temperature disconnection internal temperature monitoring with electronic disconnection Low voltage monitoring load output Starting delay t start with hysteresis, no reset necessary load OFF at U S < 8 V typically 0.5 sec after every switch-on and after applying U S Disconnection of load circuit electronic disconnection Free-wheeling circuit external free-wheeling diode recommended with inductive load Several load outputs must not be connected in parallel 203/
2 Electronic Circuit Protector ESX0 Technical data (T ambient = 25 C, operating voltage U S = DC 24 V) Technical data (T ambient = 25 C, operating voltage U S = DC 24 V) Status output SF ESX0-04/-24 plus-switching signal output, connects U S to terminal 2 of module 7plus nominal data: DC 24 V / max. 0.2 A (short circuit proof) status output is internally connected to with a 0 kohm resistor ESX0-04/-0/ -24 (signal status OUT), at U S = +24 V +24 V = S is ON, load output connected through 0V = S is ON, load output blocked and/or switch S is OFF ESX0-27 (signal status OUT inverted), at U S = +24 V +24 V = S is ON, load output blocked, red LED lighted 0 V = S is ON, load output connected through and/or switch S is in OFF position OFF condition 0 V level at status output when: switch S is in ON position, but device is still in switch-on delay switch S is OFF, or control signal OFF, device is switched off no operating voltage U S Signal output F ESX0-03/-5/-25 potential-free signal contact max. DC 30 V/0.5 A, min. 0 V/0 ma ON condition LED green voltage U S applied, switch S is in ON position no overload, no short circuit OFF condition LED off device switched off (switch S is in OFF position) no voltage U S applied Fault condition LED orange overload condition >. x I N up to electronic disconnection Fault condition LED red electronic disconnection upon overload or short circuit device switched off with control signal (switch S is in ON position) ESX0-0 single signal, make contact contact SC/SO-SI open ESX0-02 single signal, break contact contact SC/SO-SI closed ESX0-03 group signal change-over contact contact SC-SO open, SC-SI closed ESX0-05/-0/-5/-25 group signal, make contact contact SC-SO open Fault signal output fault conditions: no operating voltage U S ON/OFF switch S is in OFF position red LED lighted (electronic disconnection) Table : voltage drop, current limitation, max. load current current rating I N typically voltage drop U ON at I N active current limitation (typically) max. load current at 00 % ON duty T U = 40 C T U = 50 C 0.5 A 70 mv.8 x I N 0.5 A 0.5 A A 80 mv.8 x I N A A 2 A 30 mv.8 x I N 2 A 2 A 3 A 80 mv.8 x I N 3 A 3 A 4 A 00 mv.8 x I N 4 A 4 A A 30 mv.8 x I N A 5 A 8 A 20 mv.5 x I N 8 A 7 A 0 A 50 mv.5 x I N 0 A 9 A 2 A 80 mv.3 x I N 2 A 0.8 A Attention: when mounted side-by-side without convection the ESX0-0.. should not carry more than 80 % of its rated load with 00 % ON duty due to thermal effects. Reset input ESX0-24/-25 voltage: max. + DC 32 V high > DC 8 V DC 32 V low DC 3 V > 0 V power consumption typically 2. ma (+DC 24 V) min. pulse duration typically 0 ms Reset signal The electronically blocked ESX0-24/-27 (= terminal 3,4 or 2 may remotely be reset via an external of Module 7plus) momentary switch due to the falling edge of a +24 V pulse. Caution: unused slots The reset signal will be fed in terminal 3, 4 have to be fitted with or 2 of Module 7plus and is internally jumpers pre-wired. The reset simultaneously affects all blocked ESX0-24/-27 channels of the power distribution system, all switched on ESX0-24/-27 channels remain unaffected. With type ESX0-25 the reset only affects the device concerned. By connecting the individual terminals 2 of the Module 7plus a joint reset signal for all ESX0-25 may be generated. Control input IN+ ESX0-5 see reset input Control signal IN+ +24 V level (HIGH): device will be switched on by a remote ON/OFF signal 0 V level (LOW): device will be switched off by a remote ON/OFF signal Switch S ON/OFF unit can only be switched on with S if a HIGH level is applied to IN+ General data Fail-safe element: backup fuse for ESX0 not required because of the integral redundant fail-safe element Blade terminals.3 mm to DIN 4244-A Housing moulded Mounting plug-in mounting utilising power distribution system Module 7plus or SVSxx Ambient temperature C (without condensation, see EN 0204-) Storage temperature C Humidity 9 hrs/95 % RH/40 C to IEC , test Cab. climate class 3K3 to EN 072 Vibration 3 g, test to IEC test Fc Degree of protection housing: IP30 DIN terminals: IP00 DIN EMC emission: EN (EMC directive, CE logo) susceptibility: EN Insulation co-ordination 0.5 kv/2 pollution degree 2 (IEC 0934) re-inforced insulation in operating area dielectric strength max. DC 32 V (load circuit) Insulation resistance (OFF condition) n/a, only electronic disconnection Approvals UL 237, File # E30740 Solid State Overcurrent Protectors UL 508, File # E CSA C22.2 No: 4, File 8 CE logo Dimensions (W x H x D) 2.5 x 70 x 0 mm Mass approx. 40 g /4
3 Electronic Circuit Protector ESX0 Ordering configuration for ATEX versions:...-e Type No. ESX0 Electronic Circuit Protector for DC 24 V applications Version standard, without physical isolation in the event of a failure Signal input 0 without signal input with control input IN+ 2 with reset input Signal outputs 0 without 3 signal output F (group signal, change-over) 4 status output SF 5 signal output F (group signal, N/O) Operating voltage DC 24 V rated voltage DC 24 V Current rating A Approvals E ATEX ESX DC 24 V - A E ordering example Approvals Authority Voltage ratings Current ratings UL 237 DC 24 V A UL 508 DC 24 V A CSA C22.2 No: 4 DC 24 V A TÜV Süd/ATEX * DC 24 V A approval GL part VI part 7 * DC 24 V A IEC/EN / II 3G Ex na IIB T4 Gc X -4/-5 * auch mit Moduls 7plus Schematic diagram ESX0-24 ESX0-24- Ordering information Type No. ESX0 Electronic Circuit Protector for DC 24 V applications Version standard, without physical isolation in the event of a failure Signal input 0 without signal input with control input IN+, only ESX0-5 2 with reset input, only ESX0-24 Signal outputs 0 without, only ESX signal output F (group signal, change-over) only ESX status output SF (+24 V = OK), only ESX0-04, ESX signal output F (group signal, N/O) Operating voltage DC 24 V rated voltage DC 24 V Current rating 0.5 A A 2 A 3 A 4 A A 8 A 0 A 2 A ESX DC 24 V - A ordering example LINE (+) DC 24 V R sense LOAD (+) load output electronic control unit (-) Terminal wiring diagram ESX0-24 ESX0 S ON/OFF status indication green/orange/red reset input reset input SF status output Description of ESX0 signal inputs and outputs (wiring diagrams) see next page. Preferred types Germany Elektronischer Sicherungsautomat Electronic Circuit Protector ESX0-xx-DC 24 V-xxA UL 237 cul Preferred types Standard current ratings (A) ESX0-03-DC24V x x x x x x x x Please note: The user should ensure that the cable cross sections of the relvant load circuit are suitable for the current rating of the ESX0 used. Automatic start-up of machinery after shut down must be prevented (Machinery Directive 98/37/EG and EN 0204-). In the event of a short circuit or overload the load circuit will be disconnected electronically by the ESX0. 3 Reset IN 4 SF 2 LOAD /
4 ok I > Control unit on / off SI Electronic Circuit Protector ESX0 EG-declaration of Conformity for ATEX-version ESX0-TA/-TB-...-E Dimensions Accessories Module 7plus For technical data see section Power Distribution Systems operating area slot for fitting labels from Phoenix, Weidmüller, Wieland mounting area LINE (+) Gnd 7 plus LOAD (+) x.8=40.8 x.27= reverse plug-in protection blade terminals DIN slot for busbar G-profile EN G32 symmetrical rail EN x max. 38 max..50 off on A This is a metric design and millimeter dimensions take precedence ( mm ) inch ok Line Line module right-side terminal block left-side terminal block /4
5 Electronic Circuit Protector ESX0 Time/Current characteristic curve (T A = 25 C) disconnection typically. x I N.8 x I N The trip time is typically 3 s in the range between. and.8 x I N *). trip time in seconds current limitation typically.8 x I N IK...times rated current Electronic current limitation occurs at typically.8 x I N *) which means that under all overload conditions (independent of the power supply and the resistance of the load circuit) the max. overload before disconnection will not exceed.8 x I N *) times the current rating. Trip time is between 00 ms (short circuit current I K ) and 3 sec (at overload with high line attenuation). Without this current limitation a considerably higher overload current would flow in the event of an overload or short circuit. *) current limitation typically.8 x I N times rated current at I N = 0.5 A... A current limitation typically.5 x I N times rated current at I N = 8 A or 0 A current limitation typically.3 x I N times rated current at I N = 2 A Table 3: Reliable trip of ESX0 Reliable trip of ESX0 with different cable lengths and cross sections Resistivity of copper ρ 0 = (Ohm x mm 2 ) / m U S = DC 9.2 V (= 80 % v. 24 V) voltage drop of ESX0 and tolerance of trip point (typically. x I N = x I N ) have been taken into account. ESX0-selected rating I N (in A) 3 e. g. trip current I ab =.25 x I N (in A) ESX0 trips after 3 s R max in Ohm = (U S / I ab ) The ESX0 reliably trips from 0 Ohm to max. circuitry resistance R max Cable cross section A in mm cable length L in meter (= single length) cable resistance in Ohm = (R 0 x 2 x L) / A Example : max. length at.5 mm 2 and 3 A 24 m Example 2: Example 3: max. length at.5 mm 2 and A 0 m mixed wiring: R = 40 m in.5 mm 2 and R2 = 5 m in 0.25 mm 2 : (Control cabinet sensor/actuator level) R = 0.95 Ohm, R2 = 0.7 Ohm Total (R + R2) =. Ohm 203/
6 Electronic Circuit Protector ESX0 Table 2: ESX0 - product version version signal input signal output signal output F ESX control input ON/OFF +24 V Control IN+ reset input +24 V group signal N/O group signal change-over status output SF status OUT +24 V = OK x -04 x -5 x x -24 x x -25 x x ESX0 Signal inputs / outputs (wiring diagram) ESX0 signal inputs / outputs (wiring diagrams) Signal contacts are shown in the OFF or fault condition. ESX0-00 without signal input/output ESX0-03 without signal input with signal output F (group signal, change-over) ESX0-04 without signal input with status output SF (+24 V = load output ON) ESX with reset input (+DC 24 V ) with status output SF (+24V = load output ON) SF 3 SC 4 SO 2 SI 3 SC 4 SO 2 SF Signal operating condition: SC/SO closed, SC-SI open fault condition: SC/SO open, SC-SI closed ESX with control input IN+ (+DC 24 V) with signal output F (group signal, N/O) ESX with reset input ( +DC 24 V ) with signal output F (group signal, N/O) Reset IN 3 SC 4 SO 2 IN + Signal Control IN 3 SC 4 SO 2 3 Signal 4 operating condition: SF +24 V = OK fault condition: SF 0V Reset IN operating condition: SC-SO closed fault condition: SC-SO open operating condition: SF +24V = OK fault condition: SF 0V operating condition: SC-SO closed fault condition: SC-SO open This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted /4
Electronic Circuit Protector ESX10-T
Electronic Circuit Protector ESX0-T Description Electronic circuit protector type ESX0-T is designed to ensure selective disconnection of systems. power supplies, which are widely used in industry today,
More informationElectronic Circuit Breaker ESS20-0..
Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,
More informationDatasheet. Electronic Circuit Protection ESX10-T
Datasheet Electronic Circuit Protection ESX0-T selected in fixed values from 0.5 A...2 A. Failure and status indication are provided by a multicolour LED and an integral short-circuit-proof status output
More informationElectronic Circuit Breaker with reset input ESS20-1..
Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and
More informationElectronic circuit breaker ESS30-Sxxx-DC24V
Electronic circuit breaker ESS30-Sxxx-DC2V Description The electronic circuit protector ESS30-S with physical isolation is the globally unique electronic over protection for DC 2 V applications as a low
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker ESS for System SVS Description The electronic circuit breaker ESS is designed to ensure selective disconnection of individual loads in industrial systems which are powered by
More informationElectronic circuit protector REX12
Description The new electronic overcurrent protection REX12 consists of the supply module EM12-T and the single or double channel electronic circuit protector REX12-T which allows modular side-by-side
More informationREX12 Electronic Circuit Protector
Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double
More informationPHOENIX CONTACT
Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationPHOENIX CONTACT - 09/2009
Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationREX12 Electronic Circuit Protector
Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double
More informationPHOENIX CONTACT
Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24
More informationSmart Power Relay E I...
Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic
More informationPower Distribution System SVS18
Power Distribution System SVS8 Description The power distribution system SVS8 optimises the DC V distribution in automation and process control, in the production area of the chemical industry and in power
More informationSwitched mode power supply for DIN rail mounting type SMP23 DC24V/40A
Switched mode power supply for DIN rail mounting type SMP DC4V/40A Description Switched mode power supply (SMP) for rail mounting, three-phase supply voltage, high efficiency, integral input filter and
More informationSwitched mode power supply for DIN rail mounting type SMP21 DC24V/10A
Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive
More informationElectronic circuit protector ESX10-Sxxx-DC24V-1A-10A
Eectronic circuit protector ESX10-Sxxx-DC2V-1A-10A Description The mode ESX10-Sxxx extends our product group of eectronic overcurrent protection devices for DC 2 V appications. At a width of ony 12.5mm
More informationSolid State Remote Power Controller E
Solid State Remote Power Controller E-048-60. Description The E-T-A Solid State Remote Power Controller (SSRPC) E-048-60. is an opto decoupled transistorised switching device providing both protection
More informationPower distribution system SVS25
Power distribution system SVS Description The new power distribution system type SVS meets all requirements of the automation technology with regard to reliably overcurrent protection and optimised current
More informationPowerPlex Compact Module PP-C-COM24
Description The PowerPlex Compact Module has been designed for the 12 V or 24 V DC-System of special vehicles, buses or boats. It provides inputs for switches and sensors as well as power outputs with
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationPower Distribution System SVS02
Power Distribution System SV2 Description The ETA power distribution system SV2 is designed to accommodate the electronic circuit breaker series ESS20003 or electronic circuit protector ESX0. It distributes
More informationMINI-PS AC/24DC/1.3
Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics
More informationQUINT-PS-24DC/24DC/10
QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage
More informationPower Distribution System SVS02
Power Distribution System SV Description The ETA power distribution system SV is designed to accommodate the electronic circuit breaker series ESS0003 or electronic circuit protector ESX0. It distributes
More informationDSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.
15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty
More informationQUINT-PS/ 3AC/24DC/10
Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationQUINT-PS/ 3AC/24DC/40
Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum
More informationPHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system
More informationPower Supplies 3. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More informationDSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details
120 Watts xxx Series Ultra Slim Design - 32 mm 150% Peak Load for 3 seconds Ambient Operation from -25 C to +70 C Full Load at 60 C (24V/48V) High Efficiency - Up to 92% Volt-Free Contact for OK Selectable
More informationQUINT-PS AC/24DC/40
Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationCP-T range Benefits and advantages
Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers
More informationPHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability
More informationPhase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement
More informationQUINT-PS/ 1AC/24DC/20
Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system
More informationPower Distribution System SVS20
Power Distribution System SV Description The power distribution system SV for rail mounting distributes the current supplied by a DC V switchmode power supply to channels and selectively protects the connected
More informationMINI-PS AC/2X15DC/1
MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationMultifunctional counter tico 772/773/774
Universally applicable as a tachometer, timer, shift counter, batch counter Easy to operate Four different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48
More informationZelio Control Measurement Relays
Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and
More informationAdjustable Digital Process Instrument MDK480
Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions
More informationCP-E range Benefits and advantages
Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A
More informationUNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description
Primary-switched power supply unit Data sheet 106261_en_02 PHOEIX COTACT 2015-05-13 1 Description The power supply makes a worldwide impression thanks to maximum energy efficiency. ow idling losses (o
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationX Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters
Features RoHS lead-free-solder and lead-solder-exempted products are available Rugged 5 mm DIN-rail snap-fit design Class I equipment Universal AC-input with single stage conversion AC to DC or DC input
More informationLow profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b
Low profile safety relay with forcibly guided double contacts SFN4D RELAY 3.3 33.0 FEATURES Relay complies with EN 020, Type B. Polarized magnet system with snap action function Tolerance ±0.3 mm Weight
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More informationPower supply CP-T 24/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationPower supply CP-T 24/10.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationFor Immediate Delivery call KMParts.com at (866)
Contents 9/1 Page Description SN4 switched-mode power supply units 9/2 GW4 power supply units 9/3 GD4 power supply units 9/4 Basic Units, Accessories 9/5 Technical data 9/6 Dimensions 9/12 9/2 Description
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationA6500-UM Universal Measurement Card
Specifications Sheet A6500-UM Universal Measurement Card The A6500-UM Universal Measurement Card is a component of the CSI 6500 ATG machinery protection system. The card is equipped with 2 sensor input
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationEfficiency (typ.) (Range) Load VDC VDC ma ma(typ.) ma(typ.) μf % MCWI05-12S
FEATURES Smallest Encapsulated 5W Ultracompact SIP8 Package Ultrawide 4 : 1 Input Voltage Range Fully Regulated Output Voltage I/O Isolation 1500 VDC Operating Ambient Temp. Range40 to 75 No Min. Requirement
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationControl module CP-A CM
Control module 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP-A RU Adjustable threshold values (14-28 V) and relay outputs per input / channel Approvals Marks g 6 7 1 3 4 2 8 5 Order data
More informationV2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...
P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),
More informationCLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby
; 12Vout @ 0.25A stdby Applications Industrial equipment LED Signage Telecommunications equipment Description Features Compact size 50.8mm x 101.6mm x 36.1mm (2in x 4in x 1.4in) with density of 18W/in
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationSRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS
ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase
More informationPower supply CP-T 24/40.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationTSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys
TSX Series Modicon Manuals Presented by: Modicon PLC Schneider Electric Quantum Modicon Gould Gettys For Product Needs: Email: sales@modiconplc.com Call: 1-800-691-8511 Fax: 919-415-1614 ModiconPLC.com
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationNotes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC
Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationSHORT-FORM DATA MARKINGS. IECEx
MOSFET REDUNDANCY MODULE Single with Single Equipped with Plug-connector for Hot Swapping Suitable for all DIMENSION Power Supplies Except QT40 Series Only 150mV Voltage Drop at 40A Only 6.2W at 40A 160%
More informationType Nominal voltage (V) Code HSV V
Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More informationEMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004
Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationHG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS
20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationOperating Instructions
Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description
More informationPrimary switch mode power supplies Product group picture
Primary switch mode power supplies Product group picture /1 ABB Catalog Electronic Products and Relays 2015 2CDC 110 004 C0210 Primary switch mode power supplies Table of contents Primary switch mode power
More informationISOMETER IRDH575. Approvals
Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation
More informationAC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300
Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric
More informationTRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationThree-phase monitoring relay
1SR 550 870 F9400 Features Monitoring of three-phase mains for phase failure, over- and undervoltage Device with possibility of neutral monitoring available Device with suitability for monitoring single-phase
More informationMODEL: M2DYS SEN TRONIC AG
Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical
More informationE-STOP relays, safety gate monitors
Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel
More information