Technical data. Safety notes
|
|
- Gillian McCarthy
- 6 years ago
- Views:
Transcription
1 echnical data sheet M3A-F Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque 5 m ominal voltage AC... 4 V Control: Open-close or 3-point Damper rotation: Form-fit 8 mm echnical data Safety notes Electrical data ominal voltage AC... 4 V, 5/6 Hz ominal voltage range AC V Power consumption In operation At rest For wire sizing.5 nominal torque.4 W 3.5 VA Connection Cable m, 3 x.75 mm Functional data orque (nominal torque) Min. 5 nominal voltage Direction of rotation Reversible with switch resp. Manual override Gearing latch disengaged with pushbutton, can be locked Angle of rotation Max. 95, can be limited at both ends with adjustable mechanical end stops Running time 5 s / 9 Sound power level Max. 35 db (A) Damper rotation Form-fit 8 mm Position indication Mechanical, pluggable Safety Protection class II otally insulated Degree of protection IP54 in any mounting position EMA, Enclosure ype EMC ow voltage directive CE according to 4/8 EC CE according to 6/95/EC Certification cus according to 673-A and and CA/CSA E673-: Certified to IEC/E 673- and IEC/E Mode of operation ype Rated impulse voltage.5 kv Control pollution degree 3 Ambient temperature range C on-operating temperature C Ambient humidity range 95% r.h., non-condensating Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page Weight Approx. 48 g he actuator is not allowed to be used outside the specified field of applica tion, especially not in aircraft or any other form of air transport. Caution: Power supply voltage Assembly must be carried out by trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. he cable must not be removed from the device. When calculating the required torque, the specifications supplied by the damper manufacturers (cross section, design, installation site), and the air flow conditions must be observed. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. -M3A-F en v. 9.8 Subject to changes /
2 M3A-F Damper actuator, AC... 4 V, 5 m, Form-fit 8 mm Product features Simple direct mounting Manual override Adjustable angle of rotation High functional reliability Simple direct mounting on the damper spindle by form-fit. he actuator, with its hollow shaft, is placed over the 8 mm square spindle of the damper and secured by two screws. Manual override with push-button possible (the gear is disengaged for as long as the button is pressed or remains locked). Adjustable angle of rotation with mechanical end stops. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Accessories Description Data sheet Electrical accessories Auxiliary switch S..A.. - S..A.. Feedback potentiometer P..A.. - P..A.. Mechnical accessories Various accessories - Z-M..A../M..A.. Electrical installation otes Caution: Power supply voltage Other actuators can be connected in parallel. Please note the performance data. Wiring diagrams Open-close control 3-point control 3 3 Direction of rotation Cable colours: = blue = brown 3 = white Dimensions [mm] Dimensional drawings Damper spindle ength / -M3A-F en v. 9.8 Subject to changes
3 M..A..F / M..A..F 74-4.D ZF-MA ZF-MA ZF8-MA mm 3 mm M-M..A../M..A..F v. 9.8 /
4 M..A..F / M..A..F 3 3 AC 4 V / DC 4 V DC V (M7A..) 3 3 S S S3 3 S S S3...% M4A.. MC4A.. M7A.. MC4A.. M4A-S.. MC4A-S.. M4AP5.. AC... 4 V 3 3 S S S3 S S S3 S S S3 M3A.. MC3A.. MC3A.. M3A-S.. MC3A-S.....% AC 4 V / DC 4 V DC V DC V DC V MP M4A-SR.. MC4A-SR.. M4A-SX.. MC4A-SR.. M4A-MF.. M4A-MP.. DC V (M7A-SR..) SG..4 DC... V DC... V 3 5 M7A-SR.. AC... 4 V SG..4 DC... V DC... V 3 5 M3ASR.. / M-M..A../M..A..F v
5 M..A..F / M..A..F 74-4.D ZF-MA ZF-MA ZF8-MA mm 3 mm M-M..A../M..A..F v. 9.8 /
6 M..A..F / M..A..F 3 3 AC 4 V / DC 4 V DC V (M7A..) 3 3 S S S3 3 S S S3...% M4A.. MC4A.. M7A.. MC4A.. M4A-S.. MC4A-S.. M4AP5.. AC... 4 V 3 3 S S S3 S S S3 S S S3 M3A.. MC3A.. MC3A.. M3A-S.. MC3A-S.....% AC 4 V / DC 4 V DC V DC V DC V MP M4A-SR.. MC4A-SR.. M4A-SX.. MC4A-SR.. M4A-MF.. M4A-MP.. DC V (M7A-SR..) SG..4 DC... V DC... V 3 5 M7A-SR.. AC... 4 V SG..4 DC... V DC... V 3 5 M3ASR.. / M-M..A../M..A..F v
Technical data sheet. Technical data. Safety notes
echnical data sheet LM4A-F Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque 5 Nm Nominal
More informationPower consumption In operation At rest For wire sizing
echnical data sheet MC4A-SR-F Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx..4 m orque
More informationTechnical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC
echnical data sheet SMASR Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm
More informationPower consumption In operation At rest For wire sizing
echnical data sheet SM4A-SR-P Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque
More informationTechnical data. Safety notes. Power consumption In operation At rest For wire sizing
echnical data sheet Damper actuator NM4A-SR-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up
More informationPower consumption In operation At rest For wire sizing
echnical data sheet GM4A-SR-P Modulating damper actuator for operating air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx. 8
More informationPower consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2
echnical data sheet Rotary actuator LRA Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC... 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage
More informationElectrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing
echnical data sheet Rotary actuator LR4A Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC/DC 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage
More informationTechnical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC
echnical data sheet SMA-PC Parameterisable damper actuator for adjusting air dampers in ventilation and air-conditioning systems in buildings Air damper size up to approx. m orque 0 Nm Nominal voltage
More informationManual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool
echnical data sheet LMA-MF-P Multifunctional damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx.
More informationTechnical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2
echnical data sheet LR4A-SR Modulating rotary actuator for and -way control ball valves orque Nm Nominal voltage AC/DC 4 V Control: Modulating DC... V Position feedback: DC... V echnical data Safety notes
More informationManual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool
echnical data sheet SMA--P Multifunctional damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque
More informationPower consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)
echnical Data sheets GRK4A-SR-5 Modulating SuperCap rotary actuator with emergency setting function and extended functionalities for butterfly valves and ball valves with mounting flange ISO 511-F05 orque
More informationPower consumption Operation At rest Wire sizing
echnical data sheet NM24P-SR Modulating Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8
More informationPower consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O
echnical data sheet NRF24A-SR-S2(-O) Modulating rotary actuator with emergency function for 2- and 3-way ball valves orque or ue 10 Nm Nominal voltage AC/DC 24 V Control: modulating DC 0... 10 V Position
More informationTechnical data. Parameterisable damper actuator in the
echnical data sheet Parameterisable damper actuator in the IP66 protective housing for or adjusting ad usting air dampers in industrial plants and in technical building installations For air dampers up
More information21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque
echnical data sheet GK4A- Communicative SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for building
More informationTechnical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3
echnical data sheet H24-SR- Modulating rotary actuator in connection with a mounting kit for the motorisation of the most common mixing valves in HVAC systems orque 10 m ominal voltage AC/DC 24 V Control:
More informationOverview of types. Technical data
echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers
More informationOverview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3
echnical data sheet NRDVX4-SR--.. Modulating short stroke actuator for the motorisation of Cazzaniga and Siemens short stroke valves in HVAC systems Nominal stroke max. 5.5 mm Actuation force 500 Nm Nominal
More information11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return
echnical data sheet SF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.
More informationFunctional data Factory settings Variable Settings
echnical data sheet Rotary actuator RF-MF(-O) Multifunctional rotary actuator with emergency control for and 3 way control ball valve orque Nm Nominal voltage AC/DC V Control: Modulating DC... V or variable
More informationAC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable
echnical data sheet S--MF- Multifunctional rotary actuator for butterfly valves orque 00 Nm Nominal volta e V Control: ontrol configurable confi urable Position feedback: configurable Auxiliary u iliary
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. m² Nominal torque 5 Nm Nominal voltage AC/DC 24 V Control Modulating
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NM24A- Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque Nm Nominal voltage AC/DC 24 V Control
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet GM24A--P Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 8 m² Nominal torque 4 Nm Nominal voltage AC/DC 24 V Control
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet GR24A--R Communicative Retrofit rotary actuator for rotary valves and butterfly valves Nominal torque 40 Nm Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Position
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet SM24A--P Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 4 m² Nominal torque 2 Nm Nominal voltage AC/DC 24 V Control
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet Communicative RobustLine damper actuator for adjusting dampers in industrial plants and in technical building installations Air damper size up to approx. 2 m² orque motor Nm Nominal
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet GK24G-MF Parameterisable SuperCap damper actuator with emergency control function and extended functionalities in the IP66 protective housing for adjusting dampers in technical building
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LR24A-KNX Communicative rotary actuator for ball valves Nominal torque 5 Nm Nominal voltage AC/DC 24 V Control modulating Conversion of sensor signals Communication via KNX (S-Mode)
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet SVK24A--PC Communicative globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force 1500 N Nominal voltage AC/DC 24 V Control modulating,
More informationBrief description. Type overview
echnical data sheet VAV-Compact KNX A pressure sensor, digital VAV controller and damper actuator all in one, providing a VAV-Compact solution with a communications capability for pressureindependent VAV
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LM24A-KNX Communicative damper actuator for adjusting dampers in technical building installations Nominal torque 5 Nm Nominal voltage AC/DC 24 V Conversion of sensor signals echnical
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LH24A-00 Communicative linear actuator adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 50 N Nominal voltage AC/DC
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet SHK24A-MF Parameterisable linear SuperCap actuator with emergency control function and extended functionalities for adjusting dampers and slide valves in technical building installations
More informationElectrical data Nominal voltage AC 230 V Nominal voltage frequency
echnical data sheet SY3-30-MP- Communicative rotary actuator for butterfly valves ominal torque 50 m ominal voltage Control modulating, communicative DC (0)...0 V Variable Position feedback DC...0 V Variable
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LR24A-KNX Communicative rotary actuator for ball valves Nominal torque 5 Nm Nominal voltage AC/DC 24 V Conversion of sensor signals echnical data Electrical data Nominal voltage AC/DC
More informationExtension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..
echnical data sheet Mechanical accessories for SM..A.. Extension for ground plate Z-SMA Extension from SM.. or AM.. to SM..A.. Galvanized steel Shaft extension AV8-25 Length approx. 250 mm For damper spindles
More informationGMU24. Technical data. Dimensions [mm] For operation of air control dampers in HVAC system Torque: 40Nm Nominal voltage: AC/DC 24V Control: Open/Close
GMU24 For operation of air control dampers in HVAC system orque: 4m ominal voltage: AC/ Control: Open/Close echnical data Electrical data Functional data Working conditions Dimensions / weight ominal voltage
More information[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation
echnical data sheet EP..R-R6+BAC Characterised control valve with sensor-operated flow control, 6-way, Internal thread, PN 16 (EPIV) Nominal voltage AC/DC 24 V Control modulating, communicative wo sequences
More informationType overview. Technical data
echnical data sheet P..W..EV-BAC Characterised control valve (CCV) with adjustable flow rate and sensor-operated flow control, as well as power and energy-monitoring function, 2-way, with flange PN For
More informationAir damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control
s OpenAir Air damper actuators GDB..1E Electronic motor driven actuators for open-close, three-position and modulating control Nominal torque 5 Nm Operating voltage AC 24 V ~ / DC 24 48 V or AC 100 240
More informationRotary gear motor series AG8...
Rotary gear motor series AG8... The electric actuator belonging to AG8 series is designed to operate gas valves and air dampers in ventilation and air conditioning systems. The compact design and universal
More informationConfigured air damper actuators 6FU11xx-xDxxx-xxxx
s OpenAir Configured air damper actuators 6FU11xx-xDxxx-xxxx Electronic motor driven actuators for open-close, three-position and modulating control Nominal torque 5 Nm Operating voltage AC 24 V ~ / DC
More informationAir damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control
s OpenAir Air damper actuators SD...1A Electric motor-driven rotary actuators for open-close, three-position and modulating control 2 m nominal torque Operating voltage / DC 24 48 V or AC 100 240 V ~ Prewired
More informationNon-Spring Return EconoDrive Proportional Actuator
MSD-0x3 Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All
More informationImage. Installation VAV-Universal Retrofit-Set. General Information. Safety notes
VAV-Universal Retrofit-Set VRD-RE-SET VAV-Universal Retrofit Set for utilisation of existing VAV devices made by various manufacturers. VRD-RE-SET for air velocity up to m/s. Image Suitable only for round
More informationGLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V
4 657 Ball Valve actuators GLB...9 for valves VAI61... / Electronic motor driven actuators for three-position and modulating control, pre-wired with 0.9 m long connection cables. Remarks This data sheet
More informationUNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description
Primary-switched power supply unit Data sheet 106261_en_02 PHOEIX COTACT 2015-05-13 1 Description The power supply makes a worldwide impression thanks to maximum energy efficiency. ow idling losses (o
More informationSAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke
s 4 509 ACVATIX Electromotoric actuators for valves SAX..P with a 20 mm stroke SAX31P.. Operating voltage AC 230 V, 3-position control signal SAX61P.. Operating voltage AC/DC 24 V, control signal DC 0
More informationAdaptive control system for duct and room pressure applications. Table of Contents
Product information STP system MP BUS TECHNOLOGY BY BELIMO Adaptive control system for duct and room pressure applications Table of Contents Overview of the system 2 System description 3 Technical data
More informationPower supply CP-D 24/1.3
2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power
More informationSAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke
s 4 501 ACVATIX Electromotoric actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal SAX61.. Operating voltage AC/DC 24 V, control signal DC 0 10
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More information[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet EP..R+KMP Communicative characterised control valve with sensor-operated flow control and emergency control function, Nominal voltage AC/DC 24 V Control Modulating For closed cold and
More informationRotary actuators for ball valves
s ACVATIX Rotary actuators for ball valves GLB..9E Electromotoric rotary actuators for open-close, three-position or modulating control. Used in heating, ventilation and air conditioning plants. For 2-port
More informationTechnical Instructions Document No EA GQD June 23, OpenAir
OpenAir Spring Return, 20 lb-in (2 Nm), Rotary GQD Series, Electronic Damper Actuators Technical Instructions Document No. 155-760 EA GQD Description Features Application The OpenAir GQD Series direct-coupled
More informationRotary actuators for ball valves
4 657 Rotary actuators for ball valves GDB..9E GLB..9E for ball valves VAI61.. / VBI61.. and VAI60.. / VBI60.. / AC 230 V Electromotoric rotary actuators without spring return For 3-position and modulating
More informationSpring Return DuraDrive Proportional Actuator
MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More informationSAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle
s 4 502 ACVATIX Electromotoric rotary actuators for butterfly or slipper valves SAL.. with 90 rotary angle SAL31.. Operating voltage AC 230 V, 3-position control signal SAL61.. Operating voltage AC/DC
More informationSAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke
s 4 501 ACVATIX Electromotoric actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10 V, 4 20
More informationBrief description. VAV-Compact MP en-gb Changes reserved 1. Application. Pressure measurement. Actuator
Product information VAV-Compact MP A pressure sensor, digital VAV controller and damper actuator all in one, providing a compact solution with a communications capability for pressure-independent VAV and
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationNRT 105: Electronic fan-coil controller, equiflex
Product data sheet 4.04 R 105: Electronic fan-coil controller, equiflex How energy efficiency is improved ECO Meter for displaying the current energy consumption and digital input for the change-over between
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationAir damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V
4 614 OpenAir T Air damper actuators Rotary version with spring return, / DC 24 48 V / AC 230 V GA..1 Electronic motor driven actuators for two-position, three-position, and modulating control, nominal
More informationPower supply CP-D 24/4.2 Primary switch mode power supply
Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution
More informationM7061 ROTARY VALVE ACTUATORS
M0 ROTARY VALVE ACTUATORS PRODUCT DATA FEATURES Protected against overload and blocking Maintenance-free electrical actuator for rotary valves Clear position indicator Direct mounting on rotary valves
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationSAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke
s 4 501 ACVATIX Electromotoric actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal SAX61.. Operating voltage AC/DC 24 V, control signal DC 0 10
More informationPower supply CP-E 12/10.0 Primary switch mode power supply Data sheet
2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer
More informationRotary actuators for ball valves
4 657 Rotary actuators for ball valves GDB..9E GLB..9E for ball valves VAI61.. and VBI61.. / AC 230 V Electromotoric rotary actuators for 3-position and modulating control, pre-wired with 0.9 m long connection
More informationPower supply CP-D 12/2.1
2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power
More informationRoom Temperature Controllers. for heating and cooling systems
3 041 RCU10 RCU10.1 Room Temperature Controllers for heating and cooling systems RCU10... Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Operating modes:
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More information* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More information[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet EP..R+MOD Communicative characterised control valve with sensor-operated flow control, 2-way, internal thread (EPIV) Nominal voltage AC/DC 24 V Control communicative For closed cold
More informationPower supply CP-E 48/5.0 Primary switch mode power supply Data sheet
2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated
More informationELECTRIC ACTUATOR. Quarter turn(rotary type) - ZGQ Series
ELECTRIC ACTUATOR Quarter turn(rotary type) - ZGQ Series Construction (Inside) - Manual handle - Limit switch cam - Limit switch - Stopper - Cable entries - Valve bracket - Indicator - Motor (Reversible
More informationLM Series Direct Coupled Actuator
LM Series Direct Coupled Actuator Small Yet Powerful Minimum in-lb torque in a compact package. For damper areas up to 8 sq-ft*. Quiet Plus VAV terminal unit by Warren Technology Areas of Application VAV
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-32 A - 200..480V - 7.5..15 KW Main Range of product Product or component type Product destination Product specific application Device short
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationOpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc
Document No. 155-187P25 EA GDE/GLB-1 OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc Description The OpenAir direct coupled 24 Vac non-spring
More informationMINI-PS AC/2X15DC/1
MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths
More informationNon-Spring Return DuraDrive Modulating Actuator
MS41-60xx Series n-spring Return DuraDrive Modulating Actuator The DuraDrive direct coupled 24 Vac non-spring return rotary electric actuators are designed for modulating control of dampers. S41-60xx ries
More informationSAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force
4 584 ACVATIX Electromotoric actuators for valves SAT.. with a 5.5 mm stroke and 300 N positioning force SAT31.. Operating voltage AC 230 V, 3-position control signal SAT61.. Operating voltage AC/DC 24
More informationATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-22 A - 200..480 V - 4..11 KW Price* : 195.00 GBP Main Range of product Product or component type Product destination Product specific application
More informationGM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology
GM-MFT US Proportional damper actuator, non-spring return, Multi-Function Technology GM-MFT US Torque min. 0 in-lb Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) pplication For proportional modulation
More informationCOMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15
COMMERCIAL Bray Controls Commercial Diision 13788 West Road, Suite 200A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-412-2729 Fax: 1-888-412-2720 www.braycommercialdiision.com GA Series - Actuator
More informationElectronic circuit protector REX12
Description The new electronic overcurrent protection REX12 consists of the supply module EM12-T and the single or double channel electronic circuit protector REX12-T which allows modular side-by-side
More informationElectronic Circuit Breaker ESS20-0..
Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,
More informationProduct Data Sheet 3252J/2H3PU
3252J/2H3PU INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 7 3.3
More information1-phase AC current voltages/frequencies Volt Volt
General information AC 01.2 actuator controls for controlling multi-turn actuators of the SA/SAR.2 type range and part-turn actuators of the SG/SGR type range with interface. Features and functions Power
More information