HILAND TRAY FORM AND FUNCTION MATERIAL SPECIFICATIONS DESIGN GUIDE ROOFING I WALLING

Similar documents
ALPINE TRAY. To get the best from this product please follow these recommendations.

DESIGN GUIDE Topdek 7 00

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

When you need a clearspan of up to 6 metres of longrun steel you need...

Eurostyle SPANlok PROFILE TECHNICAL SUMMARY. Description. Spanlok 450. Dimensioned Drawing of Spanlok 450 with swages

Safety Glasses Safety Gloves Ladders Measuring Tape Spirit Level String Line. Tin-Snips Rivet Gun Caulking Gun Silicone Socket Set

LONGLINE 305 WA design and installation guide western australia

Euro-Tray Roll Cap. Specific Profile Data Sheet BACK. Table of Contents. Technical Drawing File Downloads

Lysaght Longline 305. Concealed-fixed cladding with long, clean lines

TYPICAL BARGE DETAIL - CROSS SECTION

Shingle Installation Guide

Talk to us, THE SMART ROOF PEOPLE Visit or Global Roofing Solutions Brownbuilt

ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION

TOPSPAN 22 / 40 LYSAGHT TOPSPAN 22 / 40. Steel roof and ceiling battens for non cyclonic applications

INSTALLATION GIUDE.

Finesse Profiles. Nailstrip

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE

DUTCH GABLE FREESTANDING CARPORT

CURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START

Global Roofing Solutions Klip-Tite

Global Roofing Solutions Klip-Lok 700

range of colours in COLORBOND factory pre-painted steel and in unpainted

Global Roofing Solutions Brownbuilt

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST

Pipe penetration refer CT15. Viking CertainTeed Shingles General Roof details

Steeline X-SPAN purlins

Tuff-Rib Install Guide

LYSAGHT FIRMLOK. Identification The format of the number code is: Material specifications

Global Roofing Solutions Klip-Tite

Installation. Openings: Valley: Installation on timber roofs (new buildings) 1. Fit a support (noggins) around the opening.

FIXING GUIDE. Designed for Garages & Sheds, Houses, DIY, Flat Roofs, Industrial & Agricultural Buildings etc. IS THE LONG TERM ROOFING SOLUTION

STRATCO GABLE HOMESHED STRATCO GABLE HOMESHEDS STUBBIE INSTALLATION GUIDE

Installation guide for 20/20

SpeedDeck. Fixing and Handling Guide

REDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions

Ensure there is reasonable access for materials and working space, ensure the shed site is level and consider the disposal of run-off water.

Table of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1

BROCHURE COMPANY PRODUCTS AND SERVICES

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

Three layer Felt Roofing using cold applied adhesive

GLOSSARY. A useful collection of definitions for commonly used terms in tile roofing.

TABLE OF CONTENTS A. PBR

Metroll. Purlins & Girts. C Section Purlins. C Section Purlins are manufactured from Galvaspan steel and are roll formed into C Section.

BARRELL VAULT BATTENLESS

Stratco Sanctuary INSTALLATION BEFORE YOU START TOOLS REQUIRED GUIDE

S-Rib Corrugated. Tough and Timeless in Every Sense

1 Roof Substrate (Deck) OWENS CORNING BERKSHIRE SHINGLES INSTALLATION INSTRUCTIONS

4256HM JAMES HARDIE MONOLITHIC CLADDING

Table of Contents Light Gauge Metal Roof & Wall Panels

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

BBA BRITISH BOARD OF AGREMENT CERTIFICATE NO. 87 / 1823 / C

extend your outdoor lifestyle

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

INSTALLATION GUIDE. Outback. Flat Attached BEFORE YOU START ADDITIONAL MATERIALS TOOLS REQUIRED. VERAnDAHS PATIOS CARPORTS

HOW TO Fix Onduline Corrugated Bitumen Sheets

OUTBACK FLAT ATTACHED VERANDAH PATIO CARPORT - INSTALLATION GUIDE BEFORE YOU START TOOLS REQUIRED ADDITIONAL MATERIALS

installation guide Villa

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

Polytegola N. Bitumen Roof shingles. Application guide

INSTALLATION GUIDE. Flat Roof Homesheds TM. Onto Concrete BEFORE YOU START TOOLS REQUIRED

Tuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311

How-To-build guide Garden shed

Chapter 16: Roof Steel

INSTALLATION GUIDE. Flat Roof Homesheds TM BEFORE YOU START TOOLS REQUIRED

Five Star Panel Installation Instructions

Asphalt Shingle Roofing NZ PO Box , Royal Oak Auckland

Barrel Vault Counter Batten and Batten

OWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS

Roll-Fix Kit The complete dry hip kit RFIG

Everbright E610 polycarbonate light panels Installation guidance

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

GIRTS ON BACK OF BUILDING

Basic Fitting Details No. 1

Installation Procedures

900 SERIES WALL PANELS

GLOSSARY OF TERMS SECTION 8

STEEL FRAMING WEATHERBOARD SYSTEM

WESTERN WAVE Panel. Horizontal Installation and Technical Information

WESTERN WAVE Panel. Vertical Installation and Technical Information

TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT

AS TESTED TBA FIREFLY TBA FIREFLY BAL-FZ BUSHFIRE ROOF SYSTEM INSTALLATION GUIDE EASY TO INSTALL EASY TO CARRY EASY TO TRANSPORT

Design & Install Guide. The New Standard for Commercial Roof Laps. End-Lap Solution for Insulated Panel Roofing AS WEATHER RESISTANCE

SHED PACK Step 1: Choose your shed type.

INSTALLATION GUIDE LEARN MORE AT DECRA.COM

BBS Rusticated & Splaycut Cavity System

ASSEMBLY INSTRUCTIONS GG77. BASE SIZE: 2.190m x 2.020m

Special Roofs and Vertical Slating

GABLE ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

CLEARSPAN GABLE STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. WITH GAZEBO END ATTACHED PATIO

Installation Guide. for Ampelite Industrial Sheeting STD. Premium Industrial Sheeting. Industrial Grade Fibreglass. Industrial Grade Fibreglass

15 YEAR GUARANTEE. Tough and long lasting Guaranteed waterproof for 15 years Economical and easy to fix AVAILABLE IN A RANGE OF COLOURS

Table of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8

PINEHAVEN SHEDS Assembly Instructions FOR LEAN-TO SHEDS

E-Z BUILD STEEL BARN 12' 12' 12' 16' 12' 20'

TRUE OAK CORRUGATED SERIES

MULTISPAN GABLE WITH HIP END ATTACHED PATIO

ASSEMBLY INSTRUCTIONS SS2520. BASE SIZE: 2.520m x 2.020m

REGAL. Installation Manual

Transcription:

HILAND TRAY ROOFING I WALLING DESIGN GUIDE FORM AND FUNCTION Hiland Tray is a modern 455mm wide tray roofing and walling system, roll formed onsite with a mobile roll forming facility in long single lengths and secret fixed or snap locked to roof purlins and wall girts via a simple clip system. The profile is available with the option of swages within the tray pan, or no swages for a more traditional look. The Hiland Tray profile has a high rib height of 44mm which enhances its smooth bold lines and provides greater water carrying capacity and strength for snow loading applications in alpine regions. Hiland Tray is available in 0.55mm BMT Zinc/Al and four contemporary pre-painted colour steel options to suit any home design comprising of Loch (Ironsand), Castle (Sandstone Grey), Bluff (Grey Friars), Knight (Ebony). Note: Ironsand, Sandstone Grey, Grey Friars and Ebony equivalent colour names listed are trade marks of New Zealand Steel Limited and used only for comparison. 44mm 455mm Coverage Tolerance: L±5mm W±2mm MATERIAL SPECIFICATIONS Material Properties Finish 0.55 BMT Minimum AZ Coating Mass (g/m²) Zinc/al & Colour 1 Zinc/al 2.71 Mass (kg/linear metre) Colour 2.75 Zinc/al 5.97 Mass (kg/square metre) Colour 6.05 Zinc/al 168 Yield (square metre/tonne) Colour 165 Tensile Strength (MPa) Zinc/al & Colour 340 Width Coverage (mm) Zinc/al & Colour 455 Sheet Tolerances (mm) Length & Width ±5 ±2 Minimum Roof Pitch Zinc/al & Colour 3

SPAN TABLES MAXIMUM RECOMMENDED SPANS (mm) Span Type Roofing BMT (mm) Walling BMT (mm) 0.55 0.55mm End/ Double 600 1800 Internal 900 1800 Roofing : Spans are limited based on foot traffic incidental to maintenance. Walling: Spans are based Region A, Terrain Category 2.0 wind loading, refer to the Spans table below. SPANS (mm) Terrain Category 1 2 3 Local Pressure KI End/ Double Roofing Walling Region A Region W Region A Region W Internal End/ Double Internal End/ Double Internal End/ Double Internal 1 600 900 600 900 1800 1800 1800 1800 1.5 600 900 600 900 1800 1800 1800 1800 2 600 900 600 900 1800 1800 1470 1600 3 600 900 560 620 1320 14 9 1080 1 600 900 600 900 1800 1800 1800 1800 1.5 600 900 600 900 1800 1800 1800 1800 2 600 900 600 900 1800 1800 1790 1800 3 600 900 600 900 1640 1760 1280 1410 1 600 900 600 900 1800 1800 1800 1800 1.5 600 900 600 900 1800 1800 1800 1800 2 600 900 600 900 1800 1800 1800 1800 3 600 900 600 900 1800 1800 1800 1800 FIXING RECOMMENDATIONS Hiland sheets should be laid into the prevailing wind and sit neatly on the preceding roof sheet. They should be fixed within the recommended support spacings. Avoid stretching the width of the sheet when installing, as this could allow wind and rain to enter. Edge fixing is mandatory for strength/spanning capability. This is done with 10 gauge self drilling screws to secure the standing seam to edge clips (i.e. to all clips along edges of sheet layouts). Due to the seam height, flashing turn downs into the pan of Hiland sheeting should always be notched around the rib to provide maximum weather tightness. For roof pitches less than 10, it is recommended that safety mesh is used directly under the Hiland Tray and purlin centres are reduced to 4mm. Use either roofing string or tape to support the underlay. ROOFING LAYING PROCEDURE LAYING DIRECTION PREVAILING WIND INSTALLATION DETAILS ROOFING AND WALLING Concealed Clip Fixing WIND CAPACITIES (kpa) BMT Span Type Limit State 0.55mm End/Double Internal SPAN (mm) 4 600 900 1200 10 1800 Serviceability 5.23 3.78 3.14 2.57 2.08 1.68 Strength 6.54 4.73 3.92 3.21 2.60 2.10 Serviceability 5.23 3.78 3.14 2.57 2.08 1.68 Strength 7.15 5.17 4.29 3.51 2.85 2. Capacities determined based on a minimum of two screws per clip into timber supports. ENGINEERING TESTING SYSTEMS Stratco have developed purpose built testing equipment for the testing of cladding systems sufficient to ensure the structural adequacy of the product it produces. COMPLIANCE Wind Capacity Tables are based on testing for compliance with the New Zealand Metal Roof and Wall Cladding Code of Practice. Span tables have been developed by determining relevant wind pressures in accordance with AS/NZS 1170.2. Capacity tables are in limit state format. SPANS Span tables are based on a maximum overall building height of ten metres and a 0 year design return period for strength limit state wind load assessment. Roofing spans specified are suitable for snow loading up to 2kPa in accordance with the New Zealand Metal Roof and Wall Cladding Code of Practice. Roofing calculations are based on Cpe=-0.9 and Cpi=0.2, walling is based on Cpe=-0.65 and Cpi=0.2. Local pressures are as specified and have been considered for both strength and serviceability limit states. Roof spans take into consideration loads incidental to maintenance noting ends spans allow for foot traffic over supports only. All pressures have been determined assuming wind loading in any direction without shielding but which is not affected by topography (i.e. Mt=1.0). Allocated spans do not allow for Lee Zones, for areas within these zones, utilise the wind capacity tables to calculate spans based on the relevant allowance for Lee Multipliers. Additional engineering advice can be obtained from Stratco if any design parameters vary from those indicated above. DESIGN CONSIDERATIONS Hiland Roofing and Walling has a 455mm cover with a 0.55mm BMT material thickness. The minimum allowable roof pitch is 3. Fixing to Timber Two 10 x mm wafer-head timber fixing screws (square drive recommended) per clip. Clips located at every sheet overlap and sheet edges at each timber support. Timber supports to be 100 x mm planer gauged and minimum MGP10 or F5 grade. WALKING ON HILAND When walking on Hiland Roofing, walk over the purlins to avoid damage to the sheeting. Wear flat rubber soled shoes and walk flat footed in the pans only. Walking on end spans is restricted explicitly to over the end span purlins with no access allowed directly on end spans due to potential sheet damage. MAINTENANCE REQUIREMENTS The performance of Hiland Roofing and Walling over time depends on its correct application and maintenance. Maintenance should be performed as often as is required to remove any dirt, salt and pollutants. Where Hiland cladding is used in severely corrosive environments, cleaning should be performed more often. It is important that screws have the same life expectancy as the Hiland cladding you have specified. Packs of Hiland sheeting should always be kept dry and stored above ground level on site. If the sheets have become wet, they should be separated, wiped and placed in the open to dry. Refer to the Stratco Selection, Use and Maintenance brochure for more detailed information about the correct use and maintenance of this product.

BARGE CAPPING DETAILS roofing. Self-supporting roofing underlay. mm minimum Fold 5mm maximum Gap 1 minimum Z barge flashing fixed through purlin at 200mm centres. fixed through barge board & purlin at 200mm centres. REFER TO E2/AS1 TABLE 7 Stratco fascia Selected cladding finished against soffit as per cladding manufacturers requirements. X roofing. Self-supporting roofing underlay. fixed through purlin at 200mm centres. mm minimum Fold Z barge flashing REFER TO E2/AS1 TABLE 7 Stratco fascia Selected cladding finished against soffit as per cladding manufacturers requirements.

ROOF CLADDING DETAILS flashing folded over J flashing 200 90 J flashing Fixed to purlin at 200mm centres. Form stop end to roofing tray roofing. Self supporting roofing underlay. RIDGE DETAIL Timber blocking to support & fix J flahing roofing Self supporting roofing underlay dressed into eave flashing. Stratco edge flashing fixed to purlin at 200mm centres. maximum. (Flashing coating to match roofing.) 125 20 Stratco spouting (profile & coating to be specified.) Stratco fascia. EAVE DETAIL Selected cladding finished against soffit as per cladding manufacturing requirements.

ROOF CLADDING DETAILS roofing Self supporting roofing underlay dressed into eave flashing. Stratco edge flashing fixed to purlin at 200mm centres. maximum. (Flashing coating to match roofing.) 125 20 Stratco spouting (profile & coating to be specified.) 35 J flashing with hem seam. Ensure mm minimum lap to soffit lining. J flashing with mm minimum seam. Ensure 35mm minimum cover to wall cladding wall cladding. Wall underlay Cavibat horizontal cavity system installed in accordance to manufacturers technical specifications. SOFFIT JUNCTION Selected timber lining. roofing Self supporting roofing underlay. X flashing fixed through purlin at 200mm centres. mm minimum fold 5mm maximum Gap Z barge flashing. Stratco concealed clip fixed through barge board & purlin at 200mm centres. Refer to E2/AS1 table 7 Selected timber barge. 35 5mm maximum Gap J flashing with hem seam. Ensure mm minimum lap to soffit lining. J flashing with mm minimum fold seam. Ensure 35mm minimum cover to wall cladding wall cladding. SOFFIT DETAIL 20mm drained cavity.

ROOF CLADDING DETAILS roofing Self supporting roofing underlay dressed into edge flashing. 2mm Minimum overall Valley Gutter 2 Minimum mm Minimum edge flashing fixed through purlin at 200mm centres. valley flashing turned up at each side Self supporting roofing underlay continuously over valley to separate materials VALLEY DETAIL Continuous support to valley gutter. Provide H3.1 treated timber or CCA treated plywood roofing Self supporting roofing underlay dressed into edge flashing. 2mm min. 10mm min. 200mm min. cover edge flashing Clip edge flashing onto apron flashing (Flashing coating to to match roofing.) edge flashing dressed under roofing and fold edge over to clip onto edge flashing (Flashing coating to to match roofing.) Apron flashing fixed to purlin at 200mm centres. maximum. (Flashing coating to match roofing.)turn up stop end to flashing CHANGE IN PITCH Form stop end to roofing tray.