X-ECT MX Electrical Cable Tie, X-EKS MX and X-EMTSC Conduit Clip Fastener

Similar documents
X-EKB, X-ECH Electrical Cable Fasteners

X-EKB, X-ECH Electrical Cable Fasteners

BX 3 system: fasteners for Mechanical & Electrical and Interior Finishing applications

BX 3 system: fasteners for Mechanical & Electrical and Interior Finishing applications

BX 3 system: fasteners for Interior Finishing, Mechanical and Electrical and Building Construction applications

X-HS Threaded Hanger and X-CC Loop Hanger Systems

X-P High Performance Nail for Fastening to Concrete and Wood to Steel applications

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Drywall Applications. Electrical and Mechanical Fastenings

DIRECT FASTENING SYSTEMS. Hilti. Outperform. Outlast.

Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish

Drive Pins. Powder Actuated Systems. Powder Actuated Systems

INTERMEDIATE METAL CONDUIT

DIRECT FASTENING TECHNOLOGY MANUAL 2018

Fastener selection guide. Concrete fastener selection Selecting the right nail for concrete What determines nail performance

Direct Fastening Systems. Hilti. Outperform. Outlast.

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

² TL Beton-StB 07 = German technical conditions for construction materials for concrete road pavements

CLIC TOP 17. Features

Hilti HIT-1 / HIT-1 CE Adhesive Anchor System

DYNABOLT PLUS ANCHORS DYNABOLT PLUS. Anchor Details. Installation Ramset Regions. Site Map. Home Page. Performance. Next Page. Date of Issue: 9/98

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Barofor Round System (polyester coated) Panels, Posts, Accessories

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

Government Letters Job Reference 18 21

A. Product Data: For each electrical identification product indicated.

IFRC SHELTER TOOL KIT

TI: Efficient self tapping fasteners into concrete without plugs

OptiLine 45 Floor boxes

Ø 1250 * 688 mm 93 kg ± 105m

SLEEVING (CONVOLUTED) SLEEVING (SPLIT CONVOLUTED) SLEEVING (PVC) 56 AUTO MARINE PRODUCT CATALOGUE 2018/19 VISIT:

CONTENTS. Hammerscrews White Zinc Plated 2 Hammerscrews Stainless Steel A Nylon Frame Anchors Yellow Zinc Plated 3 Nylon Plug 3

Heckmann Building Products Inc. DOVETAIL SLOT AND ANCHORS SPECIFICATION SECTION MASONRY ANCHORS AND ACCESSORIES PART 1 GENERAL

1.2 Overview. Self-adhesive mounting bases and clamps for screw and rivet mounting. Typical applications

HUS 6 Screw anchor, Redundant fastening

Using Hilti powderactuated. to install suspended metal-framed gypsum board ceilings. The application. Selection of fasteners.

WELDA FASTENING PLATES

Psi casing ENd seals type Kt type du type KG/Ko type HA type stm

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

CONTENTS CABLE MANAGEMENT AND

Conduit Assemblies. Complex Assembly - FLEXAquick System

Material Specifications Technical Data

Football Goals 7,32x2,44 m

Tech Guide. Screw Anchor Performance Why use a screw anchor? Ease in installation

Nailbiter Premium Ship Auger Bits. RESI-MASTER Heavy-Duty Ship Augers

Downtown Rack. Custom logo option available

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni

Swerve Rack CUSTOM RACKS AVAILABLE

Sigma Fasteners, Inc. Section 7

Chemical composition. Type 2 as per F568: C ( ); P (max 0.048); S (max 0.058); Mn (min 0.74); B (min );

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

Cable Ties and Accessories

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

T3ss Gas Powered Tool

PART MATERIALS. Section Fencing Materials. Description

Selection table for flat & ribbon cables

Hollo Set Drop-In Anchors

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

Heatex Identification System. The Heatex Product Programme Offers:

Accessories for cable trunking

Ground Clamps Cable Tray

WESTERN WIRE PRODUCTS

ICC-ES Evaluation Report

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

Secure. Cable ties and fixing solutions

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)

Heavy duty profiles. Heavy loads with maximum stability. Profile general overview... p Heavy duty profiles... S Load data... p.

4isofast Product code Page

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

Powder Actuated Fasteners - Drive Pins

DEKFAST COMMERCIAL ROOFING FASTENERS

PIPE/CONDUIT SUPPORTS

Internal threaded version: HSC-I carbon steel internal version HSC-IR Stainless steel version (A4) Hilti anchor design software

MASONRY DRILL and CHISEL

Use the arrow keys to easily navigate through the course.

FASTENERS & ACCESSORIES

Fastener Basics. Common Fastener Types. Fastener Materials. Grade / Class and Fastener Strength

UL Construction No. 254

Clamps. Preformed Clamping Systems. Clamps. Band-It. Band-It

+ + CFA Guidance Note: Powder Actuated Fixing Systems. Ensuring best fixings practice. Contents. 1.

Ø560*336mm 4.25 kg 2100 ± 105m

HSL-3 / HSL-3-R EXPANSION ANCHOR. Technical Datasheet Update: Oct-18

Clamp Pair. Bore Diameter (mm) Clamp Material PP = Polypropylene PA = Polyamide PE = Polyethylene AL = Aluminum

Thru Wall Floor Seals For New Installation

European Technical Assessment ETA-17/1005 of

Letter of Transmittal/Submittal

Design Guide Pryda Connectors for Steel Framing

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

Dimensions Mechanical and Performance Requirements. Drop-In Anchors Hollow Wall, Steel Regular Style Drive Style...

Operations and Instruction Manual G-Lok Anchorage - Model #????? Portable Concrete and Steel Anchorage Connector ANSI Z359.

Grinding and polishing discs COMBIDISC Corundum A Abrasive disc holders

S-BT screw-in stainless steel and carbon steel threaded studs

HEXAGONAL DOUBBLE TWISTED GABION & ROCK FALL MATRESSES

ULT R A SPAC E SAV E R

METRIC LIGHTNING PROTECTION PRODUCTS

Transcription:

D X-ECTMX, X-EKSMX, X-ECT MX Electrical Cable Tie, X-EKS MX and Conduit Clip Fastener Product data Dimensions X-ECT MX X-EKS MX X-EKSC MX 18 X-GHP 20 X-GN 27 X-EGN 14 X-U 16/22/27 4 12.5 24.5 19 24.9 14 12.5 37.4 o 6.8 1.8 20 21.8 General information Material specifications X-ECT and X-EKS: Polyamide (halogen and silicon free), light grey RAL 7035 and PBT (silicon free, flame retardant), stone grey RAL 7030 : Galvanized steel sheet f u = 270 420 N/mm 2, 10 20 μm zinc coating Nails: Carbon Steel HRC 58 X-GHP 20, X-EGN 14, X-U HRC 53.5 X-GN 27 Zink coating 2 8 μm X-GHP 20, X-GN 27, X-EGN 14 5 13 μm X-U Fastening tools o 3 o 6.8 GX 120-ME, GX 100-E, DX 460 MX, DX 351 MX 1.9 See fastener selection for more details. 27 28.9 o 3 o 6.8 1.8 14 15.8 o 3 8 2.4 Ls L Approvals CSTB (France) UL (USA) X-ECT MX, X-EKS MX, X-EKSC MX (all with X-U22 MX nail) X-ECT MX 7 / 2009 2.195

Applications Examples Flexible or rigid cable conduits with cable ties Rigid conduits Cable conduits or light duty pipes Load data Design data Recommended loads Service load 1 ) Fastener [kn] X-ECT MX 0.04 X-EKS MX 0.02 MX 0.05 1 ) The recommended service load is determined by the serviceability of the plastic part. Test data (Examples) Important note: test data are for information only. Load capacity of the nails: The nail resistance is not controlling the failure of the fastener. Fastenings to concrete Average tensile Scatter Embedment Concrete failure load depth strength Nail N u,m [kn] [%] h ET [mm] f cc [N/mm 2 ] X-GHP 20 MX 1.61 52.0 14.0 52.2 X-GN 27 MX 1.91 47.1 19.2 23.7 X-U 22 MX 3.18 37.8 20.1 54.7 X-U 27 MX 4.04 35.4 24.5 30.9 2.196 7 / 2009

Application requirements Thickness of base material Concrete X-U: X-GHP, X-GN: h min =80mm h min =60mm Steel t Il 4mm tii Spacing and edge distances 50 100 cm along the cable tie. Adjust spacing as needed to achieve stability of cable tie Corrosion information These zinc-coated fasteners are not suitable for long-term service outdoors or in otherwise corrosive environments. For further detailed information on corrosion see relevant chapter in Direct Fastening Principles and Technique section. Application limits No general restrictions existent. Limitations are depending on application and user requirements. 7 / 2009 2.197

Fastener selection Suitable cables with X-ECT MX fastener Cable type Cable measure [ mm] No. of cables NYM 3x1.5 8 14 NYM 5x1.5 10 10 Suitable conduits with X-EKS / X-EKSC MX fastener Conduit type Conduit size [mm] No. of conduits Plastic conduit 16 40 1 Suitable conduits with MX fastener Conduit type Conduit size [inch] No. of conduits Metal conduit 1 /2 1 1 Fastener program Nail Shank Ø *) Shank length*) Base material Technology d s [mm] L s [mm] L [mm Concrete X-U 22 MX DX 4.0 22 Concrete X-U 27 MX DX 4.0 27 Steel X-U 16 MX DX 4.0 16 Concrete X-GHP 20 MX GX 3.0 20 21.8 Concrete or masonry X-GN 27 MX GX 3.0 27 28.9 Steel X-EGN 14 MX GX 3.0 14 15.8 *) Standard chank diameters and shank lengths. Other combinations available on special order. Tools: DX technology: DX 460-MX, DX 351-MX GX technology: GX 120-ME, GX 100-E 2.198 7 / 2009

X-EKS 285719 X-EKS 16 MX 285720 X-EKS 20 MX 285721 X-EKS 25 MX 285722 X-EKS 32 MX 285723 X-EKS 40 MX X-ECT 285709 X-ECT MX 285710 X-ECT UV MX 285711 X-ECT FR MX 228338 1 /2 MX 228339 3 /4 MX 228340 1 MX GX nails 338872 X-EGN 14 MX 340229 X-GHP 20 MX 34541 X-GN 27 MX DX Nails 237344 X-U 16 MX 237346 X-U 22 MX 237347 X-U 27 MX X-EKSC 274083 X-EKSC 16 MX 274086 X-EKSC 20 MX 274087 X-EKSC 25 MX 386469 X-EKSC 32 MX 386470 X-EKSC 40 MX System recommendation DX tools: Steel: 6.8/11M red cartridge Concrete: 6.8/11M yellow cartridge on green/fresh and standard concrete 6.8/11M red cartridge on precast, old and hard concrete Masonry: 6.8/11M green cartridge GX 120 tool: GX 100 tool: Tool energy adjustment by setting tests on site. Gas can GC 21 (GC 22 in USA) Gas can GC 11 (GC 12 in USA) 7 / 2009 2.199

Fastening quality assurance Installation 1. Load X-EKS,X-ECT or in the tool. 2. Apply X-EKS,X-ECT or to surface with tool, compress the tool and pull the trigger. 3. Turn down the X-EKS clip or assemble a cable binder into the X- ECT (Example: X-EKS) 4. Fasten the cable to the X-EKS clip, the X-ETC or the (Example: X-EKS) Spacing: 50 100 cm along the cable tie Adjust spacing as needed to achieve stability of cable tie 2.200 7 / 2009