BCA 9RK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

Similar documents
BCA 9SK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

ARCO Rk.5 Digital Mobile C-Arm

MILADY. Product Data. Page 1 of 8

Distributed by. Ecotron Anyview Series. The Intelligent C-Arm System

Technical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension

Technical information. X-RAY PRODUCTS/Integrated solutions

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW Digital RF System - HF51-5

Digital Panoramic X- Ray unit. Product Data

Corsix R 32 Accu PRODUCT DATA

Digital Radiography X-Ray System. X Twin with X Mobil Roesys GmbH [rshsmi] 1/11

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

CT-XGEO GC FTW EN

SAMSUNG SMART DIGITAL RADIOGRAPHY. XGEO GU60A series REDEFINING ERGONOMICS

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

TECHNICAL DATA. GIOTTO IMAGE SDL/W is pre-arranged for Full Field Digital Biopsy examination with the patient in prone position.

PLD5600A High Frequency Digital Gastrointestinal &DR System(630mA)

76 cm. Ziehm 8000 Technical Specifications

Philips XPER FD10C R7.0.4

MobileDaRt Evolution MX8 Version

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R

MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.

Digital Radiography System

CIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85

New spectral benefi ts, proven low dose

Rotating Anode X-ray Tube Assembly

universal Digital Radiography (DR) System

GE AMX 4+ Portable X-Ray

MTH-R. C-arm mobile unit

X-RAYS - NO UNAUTHORISED ENTRY

C506-E064. Full digital system. Printed in Japan A-NS

Product data Remote Controlled Table

x_ray solutions We understand that customers don t need just products, they want solutions

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

Product Information PI

Quality imaging, practical investment. Philips DuraDiagnost specifications

Best choice in all DR. Jumong M. SG HealthCare Jumong M Digital radiography specifications

It s all about you. Philips BV Endura functional description

DIAGNOSTIC RADIOLOGY TECHNOLOGIST COMPENTENCY CHECKLIST. Name date assessment/orientation by date

Mammograph FFDM PRODUCT DATA

Making the difference with Live Image Guidance

Rotating Anode X-ray Tube

Portable Digital X-ray

Product Information PI

Rotating Anode X-Ray Tube Housing Assembly. General Data

Product Information PI

Product Information PI

R&F X-ray systsem. Savings With Every Exposure

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :

XRC X-Ray Calibration System

Initials. Policy #:

Maximizing clinical outcomes

Making the difference with Live Image Guidance

ART Plus CdTe-Sensor Technology

Medical Imaging. Latest generation bucky room. system. radiology ahead

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

P R O D U C T C A T A L O G ( E G Y P T ) V E R S I O N 1. 1 / M A R C H

Truly flexible to meet your clinical needs

X-ray Tube and Generator Basic principles and construction

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

Quality Design Because you pay more and more attention to the look and effectiveness of your practice

AeroDR X60. Motorized X-ray System

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

Practix. Mobile Radiography. Changing its point of view comes naturally. Practix 300

MULTIX PRO/TOP, VERTIX Solitaire, VERTIX PRO/TOP

HIGH-RESOLUTION DIGITAL PHOTOSPOT SYSTEM years, CMT s technology is today proven in more than 4,500 clinical installations PRODUCT SPECIFICATION

English. Where quality becomes beauty

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

Picasso-Trio 3-D Dental Imaging

Tomosynthesis. Energy Subtraction. Long View Imaging

FMT18 FLOOR MOUNTED SYSTEM

Economy & Performance Without Compromise SIREMOBIL Compact

Practix. Mobile Radiography. Constantly on the move, and yet never tired. Practix 160

M517-E077A O P E R A T I O N G U I D E

ARU-01CF Portable X-Ray NSN:

MULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire X-ray systems for radiographic rooms that make life easier

Precision Performance Power

ODYSSEY HF SERIES. ULTRA High Frequency X-Ray Technology. Precision... Performance... Power. Innovations in Digital Imaging.

Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL. Version 1.0

Remote Controlled Tables BACCARA 90/20 & 90/25 HV

China Resources Wandong Medical Equipment Co., Ltd. New Oriental 1000M Digital Radiography System

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

Ultimate DR flexibility

Basic Mobile Radiographic Unit. User s Manual

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

YSF - 300/DAR i

NeuViz 16 Computed Tomography. Elevating routine imaging for exceptional results

Fully motorised digital U-arm system

X o- System. Chiro- Systems. Chiropractic X-Ray Systems and Digital Solutions. Digital Radiography Computerized Radiography Chiropractic Systems

C501-E029C. RADspeed. GENERAL RADIOGRAPHIC SYSTEM Automatic

The European Manufacturer Group. The European Manufacturer Group

1. Carlton, Richard R., and Arlene M. Adler. Principles of Radiographic Imaging: An Art and a Science, 5th edition (2013).

MAN Revision 002. InSight Mini C-arm Imaging System Technical Reference Manual

siemens.com/luminos-fusion Luminos Fusion The 2-in-1 system that fits your needs and fits your budget

EXTRACORPOREAL SHOCK WAVE LITHOTRIPSY SYSTEM

X-FRAME DR2S SYSTEM. Chest and General X-Ray DR system PRODUCT DATA

MOBILEART eco C504-E009G

OTC18 OVERHEAD TUBE CRANE SYSTEM

Transcription:

ELECTRICAL CHARACTERISTICS RADIOLOGICAL DATA MONOBLOC Voltage 230 Vac ±10% monophase standard 105 / 115 / 125 / 220 / 240 Vac ±10% monophase on request Frequency 50 Hz standard 60 Hz on request Absorbed current on Stationary 4.5 A @ 230 Vac and 7.5 A @ 115 Vac in fluoro mode Anode Unit 20 A @ 230 Vac and 28 A @ 115 Vac in radiography mode Line compensation Automatic Line resistance < 0.4Ω (supply at 230V) < 0.2Ω (supply at 115V) Standard mains plug 16 A (for supply at 230 Vac) Generator power in DC current 5 kw (100 kv, 50 ma, 64 ms) High frequency inverter 40 khz Max. Ripple <2% @ 100 kv Max high voltage 120 kvp (radiography and fluoroscopy) Max current in continuous fluoroscopy 8 ma Max current in fluoroscopy Boost 12 ma Max current in radiography 25 ma @ 230 V 18 ma @ 115 V Max mas in radiology 125 mas @ 230 V 90 mas @ 115 V Exposure Time in radiography 0.04 5 sec Anode Rotating Anode inclination 10 Focal Spot size according to IEC 336 0.3 mm small focus 0.6 mm large focus Nominal anodic power 5 kw small focus 17 kw large focus Max anode cooling speed 33 khu/min (25 kj/min) Monobloc thermal capacity 600 kj (670 khu) Max continuous thermal dissipation 75 W, 102 HU/sec, 6120 HU/min of the monobloc Max. Fluoroscopy time HU safety after 28' of fluoroscopy @ 120 kv, 5 ma (600 W) Max fluoroscopy time @75W 75 kv - 1mA - Continuous fluoro (no limits) Max fluoroscopy time @280W 80 kv - 3.5 ma - 54 Minutes Max fluoroscopy time @400W 100 kv - 4 ma - 38 Minutes Max fluoroscopy time @525W 70 kv - 7.5 ma - 31 Minutes Max fluoroscopy time @550W 110 kv - 5 ma - 30 Minutes Max fluoroscopy time @600W 120 kv - 5 ma - 28 Minutes Total filtration > 2.7 mm Al

COLLIMATOR Type Standard: Iris + parallel shutters Iris Orientable shutters Control by console with adjustable continuous opening until the max. allowed in function of the I.I. field selected. Iris automatic limitation on the I.I. field selected Control by console for the opening/closing and clockwise/ anti-clockwise rotation IMAGE INTENSIFIER TUBE - 9/6/4 Field Number 3 Input nominal diameter 230 mm Resolution (central) 48 / 56 / 64 lp/cm Conversion factor 240 / 120 / 60 (cd. m -2 / mr. s -1 ) Contrast Ratio 23:1 / 25:1 / 30:1 DQE @ 59.5 kv 65% MTF 60% / 65% / 70% @ 10 lp/cm 25% / 30% / 40% @ 20 lp/cm Integral Distortion 4% / 2% / 1% All metal Technology Input screen Hi-Res Antiscatter fixed grid Ratio 8:1, 36 shutters/cm, focus 80 cm CCD CAMERA 1K X 1K Technology CCD interline progressive scanning Active pixels 1024 x 1024 Acquisition Matrix 1024 x 1024, 10 bits Contrast resolution 1024 grey levels Sensitivity 0.2 lux (PB20 light) Signal - Noise Ratio 60 db

DIGITAL IMAGE SYSTEM WITH 1K x 1K CCD CAMERA CHARACTERISTICS HRC 1000 TYPE WITH STANDARD DICOM ESIDIC 3 Image acquisition 1024 x 1024 with frame integrations up to 16 bit Image storage 1024 x 1024 x 10 bit up to 256 frames. REAL TIME PROCESSING Number of images L.I.H Last Image Hold + 256 image, output for 2 monitors Frame acquisition rate (fps) Single store image, until to 256 ram image in ram or 50.000 frame on DICOM hard disk Gamma correction, digital Recursive filter / Smart filter, 0, 2, 4, 8, with smart filter, motion detector Real time image rotation RDR/S Digital rotation LIH Edge enhancement, Sharp matrix 3 x 3 Dynamic range 1:2 1:3 1:4 1:5 POST PROCESSING ARCHIVES AND DATA PATIENTS Grey scale inversion Contrast and brightness Overview, Windowing, 4, 9, 16 frame, 1 + 5 frame or 1 + 7 frame Image Rotation steps, 90-180 - 270-360 Horizontal, Vertical image inversion Electronic zoom, from 1, 2 to 3 factor Angles measure Length measure Length calibration on reference object Text overwriting, on image Electronic Shutter for best quality image on printer Print in BMAP format, on windows printers Image storage 50.000 on DICOM hard disk Data patient SCU, Service Class Verify Connection Standard supported by ESIDIC 3 Dicom toward server or printer connection SCU, Service Class Storage toward Standard supported by ESIDIC 3 Dicom server SCU, Service Class Print with film Standard supported by ESIDIC 3 composer toward Dicom printer SCU, Service Class Work List from Standard supported by ESIDIC 3 Dicom server for downloading patient list Media Interchange CD Rom Standard supported by ESIDIC 3

MONITORS MONOCHROME LCD DISPLAY VERSION Panel size / type 18" 18.1 TFT active matrix LCD anti-glare and hard coated, medical. HARDWARE REQUIREMENTS Brightness and contrast controls OSD menu ELECTRICAL CHARACTERISTICS Standard power supply 100 to 240 Vac 60 / 50 Hz Current absorbed 1.4 A Power absorbed 60W DISPLAY CHARACTERICS Visibility angle 170 Contrast 400:1 Resolution 1280 x 1024 Active Display area 359 mm (H) x 287 mm (V) Pixel pitch 0.2805 x 0.2805 mm Gray scale 256 x 3 = 768 levelss Max luminance 750 Cd /m 2 Aspect ratio 4:3 ENVIROMENT AND RELIABILITY Operative Temperature: from 5 to +35 C Humidity: 20% to 80% (non condensing) Temperature and storage Temperature: from -20 to +5 C Humidity: 10% to 90% (non condensing)

FUNCTIONALITY DESCRIPTION DATA User s interface Selectable languages I.I. field selection Thermal units Fluoroscopy control On Stand Monitor position Safeties Membrane keyboard with alphanumeric touch-screen 5.7 LCD display for all the operative parameters and messages of eventual faulty conditions. Microprocessor management. User interface control could be rotate of 60 Italian, English, French, German, Spanish (selection by set-up) Electronic zoom selection according to the number of I.I. fields with automatic limitation of the radiated field by the iris collimator. Check and visualization in real time of thermal units on the display according to the applied load. From 100% to 5% XR enabled. When there are 5 minutes of fluoroscopy (for the kv and ma values in use in that moment) to reach the 5% of the HUT, a particular audio-visible signal is activated. If more than 5 minutes are necessary to finish the exam, the fluoroscopy data have to be lowered. After reaching the 5% of the available HUT, the x-ray emission is stopped (*). In order to go on with the fluoroscopy, it is necessary to wait that the HUT have reached at least the 10%. (*) In particular conditions it is possible to exclude this block and go on with the exam, under the direct responsibility of the qualified personnel or the doctor that uses the unit. In radiography it is not possible to control the x-ray emission any more when the 5% of the available HUT is reached. Multi-functioning foot switch: Pedal for continuous, pulsed and single shot (boost) fluoroscopy (functions selection by 3 different foot switches). Storage image on memory by foot switch without interrupting fluoroscopy General magneto-thermic switch Key safety switch Emergency pushbutton Printer for Dose Area meter (optional) Directly on the stand with 1 monitor LCD orientable 17 NL series or: Monitor trolley with five wheels, two of them with stationary brake Lamp for x-ray emission warning Cable winding support Digital system with CCD 1K x 1K Two monitors LCD 18 Alphanumeric keyboard Memory HRC1000 Dicom Trasmission Unit ESIDIC3 Filament current Monobloc temperature Overload kv min/max. or fault H.V. Stored data check

OPERATIONAL MODES WITH 1K x 1K CCD CAMERA OPERATIONAL MODES MODE CHARACTERISTIC PERFORMANCES Continuous Dose control (kv - ma) Automatic or manual fluoroscopy Small Focus 0.3 mm (IAE Tube) kv variation range 40-120 kv ma variation range 0.5-8 ma kv - ma correlation Standard: 40 kv / 0.5 ma, 80 kv / 7.6 ma, 120 kv / 8 ma Safety timer Audible alarm resettable after 5 x-ray x-ray stop after 10 of continuous radiations according to IEC 60601-2-7 29.1.104 Last image hold (LIH) Pulsed fluoroscopy Range of exposure rate variation (Selectable by console) From 2 image/sec to 1 image every 5 sec (2 image / 1s; 1 image / 1s; 1 image / 2s; 1 image / 3s; 1 image /5s) XR flash time Minimum time for better image Other characteristics as per the continuous fluoroscopy One-shot Digital ma variation range 2.5-30 ma Radiography XR flash time < 1 sec Acquisition obtained by integrating 16 following readings Automatic storage of the image on RAM or nonvolatile memory, according to the memory type Other characteristics as for the continuous fluoroscopy ma 1/2 fluoroscopy ma variation range 0.25-4 ma kv - ma Correlation 40 kv / 0.25 ma, 80 kv / 3.8 ma, 1 20 kv / 4mA Other characteristics as per the continuous fluoroscopy Anatomic APR APR 1 ma Low Anatomic fine parts or paediatric use selection, in from 0.7 ma to 6.6 ma 40 kv / 0.7 ma, fluoroscopy 80 kv / 6.4 ma 120 kv / 6.6 ma APR 2 ma Low Lungs from 0.5 ma to 7 ma 40 kv / 0.5 ma 80 kv / 7 ma 120 kv / 5.5 ma PR 2 ma High Head, spinal column, pelvis from 1 ma to 15 ma 40 kv / 1 ma, 70 kv / 15 ma 120 kv / 9 ma The curves cannot be modified by the operator Radiography Working technique 2 points with kv and mas setting Large Focus 0.6 mm (IAE Tube) kv variation range 40-120 kv APR anatomic selection in radiography ma variation range mas variation range Times range Use coefficient (duty cycle) @ 230 Vac 25 ma fixed from 40 kv to 100 kv; 20 ma at 120 kv @ 230Vac 1-125 mas from 40 to 100 kv 1-100 mas from 101 to 120 kv in 42 steps, R 20 curve 0.04-5 sec max @ 115 Vac 18 ma fixed from 40 kv to 100 kv; 15 ma at 120 kv @ 115Vac 1-90 mas from 40 to 100 kv 1-71 mas from 101 to 120 kv Calculated as per the anode dissipation Description Norm Paediatric Adult APR 1 Head 77 kv 56 mas 74 kv 45mAs 80 kv 71mAs APR 2 Lungs 110 kv 11 mas 107 kv 9 mas 110 kv 14 mas APR 3 Pelvis 85k V 22 mas 82 kv 28 mas 88k V 18 mas Possibility to change and store with every APR: kv and mas

ENVIRONMENTAL CONDITIONS Environmental condition in Normal Use Environmental condition in Transport and Warehouse Temperature: Humidity: Pressure: Temperature: Humidity: Pressure: from +10 to +40 Celsius from 30% to 75% non condensing from 700 to 1060 hpa from -25 to +70 Celsius from 10% to 90% not condensing from 500 to 1060 hpa WEIGHT AND DIMENSION Description Stand Trolley, mod. "Low" Trolley, mod. "Standard" Trolley, mod. "High" Weight About 360 kg About 67 kg About 97 kg About150kg (1) Width 859 mm 830 mm 870 mm 872 mm (2) Depth in transport position 2000 mm 855 mm 855 mm 577 mm (3) Height in transport position 1800 mm 1605 mm 1605 mm 1603 mm Weights and dimensions can vary with different accessories MECHANICAL CHARACTERISTICS Vertical motion Horizontal motion 500 mm motorized in 60 sec 210 mm Panning motion ± 270 Orbital rotation 123 (+90-33 ) Pivotal rotation ± 12.5 Free Space Depth S.I.D. Focus Skin distance Movement Stand Wheels diameter Trolley Wheels diameter Protection against cables squashing 770 mm 690 mm 970 mm 200 mm Manual. Steering rear wheels with manual control by the operator, swiveling front wheel. Stationary brake by hand Rear: Double wheels 125 x 40 mm Front: Double wheels 80 x 30 mm Base Trolley 5 x 80 x 35 mm with brake High configuration Trolley 4 x 125 x 30 mm with brake Semi-rigid rubber core-hitch on all the wheels of the stand.

TECHNICAL DATA STAND Dimension in mm (D) - 33 (D) 90 (C) ±270 (H) (I) (F) 770 [30,31] (G) 690 [27,17] 848 [33,39] (3) 1800 [70,87] (2) 2000 [78,74] (1) 859 [33,82] (E) ±12,5 520 [20,47] 675 [26,57] 954 [37,56] (L) (M) (N) 557 [21.93] 1835 [72,24] (B) 210 [8,27] FIXED ANODE ROTATING ANODE (H) 988 mm 970 mm (I) 218 mm 200 mm (L) 172 mm 152 mm (M) 339 mm 357 mm

TECHNICAL DATA TROLLEY MOD. "STANDARD" Dimension in mm 439 [17,28] (1) 869 [34,21] 1021 [40,20] 694 [27,32] 1378 [54,25] (3) 1606 [63,23] 352 [13,86] 431 [16,97] (2) 855 [33,66]

TECHNICAL DATA TROLLEY MOD. "HIGH" 441 545 859 1061 1131 1061 1372 65 352 1548 352 600 Note Technical Specs can be subject to changes, in order to grant the highest quality levels, and so they can vary without ntice obligation ESSE 3 Via Garibaldi 30 14022 Castelnuovo D.B. (AT) tel +39 011 99 27 706 fax +39 011 99 27 506 e-mail esse3@tuttopmi.it web : www.4ci.com