LOW-PROFILE SURFACE-MOUNT RELAY

Similar documents
LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

HIGH INSULATION RELAYS (Conforming to the supplementary insulation class of EN Standards (EN41003))


LOW PROFILE 2 FORM C RELAY TQ RELAYS Ð Ð.008. mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC. 200 mw.

SMALL POLARIZED RELAY WITH HIGH SENSITIVITY

New pin layout (LT type) added. Best seller with broad lineup and AC 2000 V breakdown voltage.

HIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

High breakdown voltage type is available (1.5 kv between open contacts)

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

High Sensitivity, with 100mW nominal operating power, in a compact and space saving case

2 AMP. HIGH CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE FEATURES. Characteristics. Initial breakdown voltage

ULTRA LOW PROFILE 2 AMP. POLARIZED RELAY. mm inch. Initial breakdown voltage

LOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

RK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY


8 A MINIATURE POWER RELAY IN DS RELAY SERIES

HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY FEATURES. Max. operating speed. Initial. Reset time* 3 (at nominal voltage)

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

1.5 GHz MICROWAVE RELAYS. FEATURES 1. Excellent high frequency characteristics. V.S.W.R. (Max.) 1.5 (at 900 MHz) Impedance

8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES

16A POWER RELAY FOR MICRO WAVE OVEN

1 GHz capable, 3 W carrying power (at 1 GHz), 50Ω impedance and 2 Form C relays


MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

COMPACT PC BOARD POWER RELAY

4 AMP POLARIZED HIGH DENSITY RELAY WITH HIGH SENSITIVITY FEATURES

HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY

COMPACT PC BOARD POWER RELAY

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

COMPACT PC BOARD POWER RELAY FEATURES. Characteristics. Initial breakdown voltage* 1. Vibration resistance

10 A MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A 1 Form A. Initial breakdown voltage* 2. Vibration resistance.

1a 16A power relay for micro wave oven

Compliant with European standards 1a/1c 6A Slim power relays

1a/1c 5A/10A small power relays

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

ULTRA-SMALL PACKAGE SLIM POLARIZED RELAY FEATURES

Suitable for lighting and motor load, 1 Form A 50A latching relays

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A. 1 Form B. Initial breakdown voltage* 2 8 A 250 V AC 8 A 30 V DC 250 V AC, 30 V DC

Compact Relay Family with Forcibly Guided Contacts

1a/1c/2a/2c/5A/10A power relays for power supply

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES


MINIATURE RELAY FOR WIDER APPLICATIONS

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

1a/1c/2a/2c/5A/10A power relays for power supply

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

SUPER MINIATURE TWIN TYPE AUTOMOTIVE RELAY FEATURES

SLIM COMPACT SAFETY RELAY

Transistor drive 2c/4c 5A slim power relays

Compact Flat Size Relay for Automotive. (Unit: mm inch)

1a 8A, 1a1b/2a 5A small polarized power relays

1a 8A, 1a1b/2a 5A small polarized power relays

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

MICRO-ISO AUTOMOTIVE RELAY

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY FEATURES

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

UP TO 8GHz SMALL MICROWAVE RELAYS

SUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

High switching capacity 1a/1c 30A power relays

AUTOMOTIVE RELAY WITH ISO TERMINAL ARRANGEMENT

3 GHz capable, 10 W carrying power (at 3 GHz), 50Ω/75Ω impedance and 1 Form C relays

1a 10 A,1a1b/2a 8 A small polarized power relays

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

UNIQUELY DESIGNED RELAY FEATURES

Load for air conditioner 1a 20A power relays

Slim compact safety relay

Micro-ISO Automotive Relay. (Unit: mm inch)

20 AMP POWER RELAY HG RELAYS

Surface-mounting Relay

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

TV-15, 30 AMP (1 Form A) Power Relay

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

HC RELAY PRODUCT TYPES

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

SPST-NO SPDT DPST-NO DPDT

Applications UD2-3 S NU -L. Series Coil Voltage Latch Type Lead Type Packaging UC2- = Through-hole mount UD2- = Surface mount

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

2-POLES 2A (SLIM PROFILE SIGNAL RELAY) FTR-B4 Series

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

RT-3 UNIT RELAY 4-POINT TERMINAL

MINIATURE SIGNAL RELAYS

MINIATURE SIGNAL RELAY MR62 SERIES

Palm-sized, 16-channel Relay Terminals

DATA SHEET. Ultra-low power, compact and lightweight, High breakdown voltage, Surface mounting type

Relay Catalogue Part 1: Electromechanical Relays. Part 2: PhotoMOS and Semiconductor Relays

Transcription:

TESTING LOW-PROFILE SURFACE-MOUNT RELAY TQ SMD RELAYS.6. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6. mm.6 inch) Tape and reel package is available as standard packing style Surge withstand between contacts and coil:, V Breakdown voltage between contacts and coil:, V Capacity: A High sensitivity: Form C power consumption (Single side stable type) SPECIFICATIS Contact Arrangement Initial contact resistance, max. (By voltage drop 6 A) Contact material switching capacity ( load) switching power ( load) Rating switching voltage switching current switching capacity (Reference value) # power Expected life (min. operations) Form C 7 mω Au-clad AgNi type A 3,. A V AC 6 W, 6. VA, V AC A µa m (. to ) Single side stable (4 ) 3 (48 ) coil latching 7 (. to ) (4 ) coil latching (. to ) (4 ) Mechanical (at 8 cpm) 8 A 3 Electrical (at cpm) A 3. A V AC Note: # This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (SX relays are available for low level load switching [, ma max. level]) Remarks * Specifications will vary with foreign standards certification ratings. * Measurement at same location as Initial breakdown voltage section. * By method, nominal voltage applied to the coil contact carrying current: A. * 3 voltage applied to the coil, excluding contact bounce time. * 4 voltage applied to the coil, excluding contact bounce time without diode. * Half-wave pulse of sine wave: 6 ms detection time: µs * 6 Half-wave pulse of sine wave: 6 ms * 7 Detection time: µs * 8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRMENT. Characteristics Initial insulation resistance* Initial breakdown voltage Initial surge voltage Between open contacts Between contact sets Between contact and coil Between open contacts ( 6 µs) Between contacts and coil ( µs), MΩ (at ), Vrms for min. (Detection current: ma), Vrms for min. (Detection current: ma), Vrms for min. (Detection current: ma), V (FCC Part 68), V (Telcordia) Temperature rise* (at C) C Operate time [Set time]* 3 (at C) 4 ms [ 4 ms] Release time [Reset time]* 4 (at C) 4 ms [ 4 ms] Shock resistance Functional* 7 m/s {7 G} Destructive* 6, m/s { G} m/s Functional* 7 {G}, to Hz at double amplitude of 3.3 mm Vibration resistance Destructive 4 m/s {3G}, to Hz at double amplitude of mm Conditions for operation, transport and storage* 8 (Not freezing and condensing at low temperature) Unit weight Ambient temperature Humidity 4 C to 8 C* 3 4 F to 8 F to 8% R.H. Approx. g.7 oz

ORDERING INFORMATI TQ SMD Ex. TQ SA L 3V Z Contact arrangement Surface-mount availability Operating function Coil voltage (DC) Packing style : Form C SA: Standard surface-mount Nil: Single side stable., 3, 4.,, 6, Nil: Tube packing SA: terminal type L: coil latching,, 4, 48* V Z: Tape and reel packing (picked from the 6/7/8//-pin side) SL: High connection reliability L: coil latching SA: surface-mount terminal type SS: Space saving surface- SA: mount terminal type *48 V coil type: Single side stable only Notes:. Tape and reel (picked from //3/4/-pin side) is also available by request. suffix -X is needed when ordering. (ex.) TQSA-3V-X. Tape and reel packing symbol -Z or -X are not marked on the relay. TYPES. Single side stable. coil latching 3. coil latching, (max.) Drop-out (min.) ma (±%) Ω (±%) : For each surface-mounted terminal variation, input the following letter. SA type: A, SL type: L, SS type: S Notes:. Specified value of the pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.. Standard packing: Tube: pcs. Case:, pcs. Tape and reel: pcs. Case:, pcs. 3. In case of V transistor drive circuit, it is recommended to use 4. V type relay. power, allowable TQS -. V..3. 3.8 6. TQS -3 V 3..3 46.7 64.3 4. TQS -4. V 4. 3.38.4 3 6.7 TQS - V 3.7. 8. 78 7. TQS -6 V 6 4..6 3.3 7 TQS - V 6.7.. 7 3. TQS - V..7,8 8 TQS -4 V 4 8.4 8.3,88 36 TQS -48 V 48 36 4.8 6.3 7,68 3 7.6 Set (max.) Reset (max.) ma (±%) Ω (±%) power, allowable TQS -L-. V..3.3 46. 3 7. TQS -L-3 V 3.. 3.3 8.6 7 4. TQS -L-4. V 4. 3.38 3.38.6 8.3 7 6.7 TQS -L- V 3.7 3.7 37 7 7. TQS -L-6 V 6 4. 4..7 7 TQS -L- V 6.7 6.7 7.8,7 7 3. TQS -L- V.8,7 7 8 TQS -L-4 V 4 8 8 4.,76 36 Set (max.) Reset (max.) ma (±%) Ω (±%) power, allowable TQS -L-. V..3.3 3.8 6. TQS -L-3 V 3.. 46.7 64.3 4. TQS -L-4. V 4. 3.38 3.38 3 6.7 TQS -L- V 3.7 3.7 8. 78 7. TQS -L-6 V 6 4. 4. 3.3 7 TQS -L- V 6.7 6.7. 7 3. TQS -L- V.7,8 8 TQS -L-4 V 4 8 8 8.3,88 36

DIMENSIS SA type SL type SS type.4..4..4........6...8 7.. 7.. 4..3 4..3 4..3 7.6.3.±..43±. 7.6.3.±..43±. 7.6.3.3±. ±....... General tolerance: ±.3 ±. Recommendable mounting pad (Top view) SA type.4.6.3..4.6.84.7.3.3.4. SL type.4. SS type.3.4..7.6.376 For glue-pad.6.376 8.46.333 Tolerance: ±. ±.4 Schematic (Top view) Single side stable (Deenergized condition) 8 7 6 3 4 -coil latching (Reset condition) 8 7 6 3 4 -coil latching (Reset condition) 8 7 6 3 4 REFERENCE DATA. Maximum switching capacity. Life curve 3. Mechanical life Tested sample: TQSA-V, pcs. Switching A 3.....4.3. AC load DC load No. of operations, 4 3 V AC load 3 load Ratio against the rated %V 8 7 6 4 3 3 3 Contact V.. Switching A IRS,, No. of operations, 4 4.-() Electrical life ( A 3 load) Tested sample: TQSA-V, 6 pcs. Operating frequency: cpm Change of contact resistance 4.-() Electrical life (. A V AC load) Tested sample: TQSA-V, 6 pcs Operating frequency: cpm Ratio against the rated %V 8 7 6 4 3 8 7 6 4 3 Ratio against the rated %V 8 7 6 4 3 IRS 3 4 6 7 8 No. of operations, 4 IRS 3 4 6 7 8 No. of operations, 4 IRS 3 4 6 7 8 No. of operations, 4

Change of contact resistance. Coil temperature rise Tested sample: TQSA-V, 6 pcs. Point measured: Inside the coil Ambient temperature: C 77 F 6. Operate/release time Tested sample: TQSA-V, 6 pcs. TQ SMD 8 7 6 4 3 Temperature rise, C 7 6 4 3 Coil voltage DC V type DC 48V type A A A A Operate and release time, ms 4 3 Operate time Release time IRS 3 4 6 7 8 No. of operations, 4 3 Coil applied %V 7 8 Coil applied %V 7. Distribution of pick-up and drop out voltage Tested sample: TQSA-V, pcs. @ @@ @@ 3 @@ @@ @ 3 4 6 7 8 Ratio against the rated %V 8. Distribution of set and reset voltage Tested sample: TQSA-L-V, 3 pcs. 3 Set voltage Reset voltage 3 4 6 7 8 Ratio against the rated %V. Ambient temperature characteristics Tested sample: TQSA-V, pcs. 4 Rate of change, % 4 4 6 8 Ambient temperature, C 4 x. Distribution of contact resistance Tested sample: TQSA-V, 3 pcs. (3 4 contacts).-() High-frequency characteristics Isolation characteristics.-() High-frequency characteristics Insertion loss characteristics 4 3 Terminal Nos. 3-4, 7-8 8 7 3 4 (TOP VIEW) Terminal Nos. -3, 8-3 4 6 Isolation, db, Frequency, MHz Insertion loass, db..8.6.4., Frequency, MHz.-() Malfunctional shock (single side stable) Tested sample: TQSA-V, 6 pcs.-() Malfunctional shock (latching) Tested sample: TQSA-L-V, 6 pcs. Y X m/s Z X X' Y m/s Deenergized condition Energized condition m/s Y X m/s Z X X' Y m/s Reset condition Set condition m/s m/s Z m/s X' m/s Z m/s X' m/s m/s

3.-() Influence of adjacent mounting Tested sample: TQSA-V, pcs. 3.-() Influence of adjacent mounting Tested sample: TQSA-V, 6 pcs. 3.-(3) Influence of adjacent mounting Tested sample: TQSA-V, 6 pcs. 3.3 4 6.7.8.7.7.36 Inter-relay distance, 3.3.7 4 6.8.7.7.36 Inter-relay distance, 3.3 4 6.7.8.7.7.36 Inter-relay distance,. Pulse dialing test Tested sample: TQSA-V, 6 pcs. (3 ma 48 wire spring relay load) Circuit 48 Ω.8.8 µf µf 48 NOTES 48 Ω Wire spring relay TQ-SMD 3 relay. Packing style ) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. Stopper (gray) Orientation (indicates PIN No.)stripe Stopper (green) Ratio against the rated %V 8 7 6 4 3 IRS 3 4 No. of operations, 4 ) Tape and reel packing (surface-mount terminal type) () Tape dimensions (i) SA type Relay polarity bar 4. ±...7 ±.4 type)..7 ±. dia..4 ±.4.4..6 ±.. dia. ±..6 ±.4.7 ±.4 ±...43±.4.6 ±..7 ±.4. ±. 6.3. dia. ±.3 6. ±..3 ±. 4..48 ±.8.4.7 dia..63.484.4 ±. TQ-SMD relays ±.4 ±.4 Tape coming out direction (ii) SL, SS type Relay polarity bar 4. (Z ±..7 ±.4. (Z type)..7 ±. dia..4 ±.4.4 ±.. dia..±..6.6 ±.4.7 ±.4 ±...43±.4.6 ±..7 ±.4 ±.. 7.8. ±.3 6. ±..3 ±. 4..37 ±.8 dia..4.7 dia..63.484 ±.4.4 ±. TQ-SMD relays ±.4 Tape coming out direction (. ±. ±.4.38 )* Note) *SS type Change of contact resistance 8 7 6 4 3 IRS 3 4 No. of operations, 4 () Dimensions of plastic reel. ±..7 ±..87 ±.8 ±.3 3. ±. ±.8 4.4.7.6..7 ± dia. ±.3 3.37 dia. ± 33 dia. ±.7. dia. ±. ±.8 For Cautions for Use, see Relay Technical Information.