SECTION IDENTIFICATION SIGNS. A. Plastic Signs, raised character, tactile, room identification, exit door signs, and non-tactile signs.

Similar documents
City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines

Advisory Raised Characters. Signs that are designed to be read by touch should not have sharp or abrasive edges.

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION SIGNAGE

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

SECTION IDENTIFYING DEVICES

SECTION NON-ILLUMINATED INTERIOR DISPLAY SYSTEM

Table of Contents. Ninety Edge. BevelED Edge. Reveal Collection ENCLOSURES 7 KIOSKS 8 ARC ENCLOSURES 9 KIOSKS 10. Carve collection.

*********************************************************************************************************

A. Submit manufacturer's technical data and installation for each type of sign required.

A. Interior and exterior non-illuminated tactile building signs including Braille.

A. Submit properly identified manufacturer's literature before starting work.

SECTION IDENTIFYING DEVICES

INTERIOR SIGNAGE MANUAL

Americans with Disabilities Act (ADA) Federal Guidelines

BUILDING SIGN PROGRAM JULY 2012

SECTION INTERIOR SIGNAGE

ETCHED PLAQUES by Matthews International

SECTION INTERIOR SIGNAGE

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

BUILDING SIGN PROGRAM SEPTEMBER 2016

2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES

50948-RHN Putney. 14 Dec This document includes: N14 General internal signage systems. Code Section Revision Dated

Americans with Disabilities Act

SECTION BULLET- RESISTANT DOORS

Solid Surface Countertops

SECTION FASCIA INTERIOR FRAMED SIGNS & DIRECTORIES

APPENDIX 6. SIGNAGE TYPES: Signage as manufactured by KROY Sign Systems, N. Hayden Road, Scottsdale AZ 85260

Solid Surface Fabrications

CENTRAL MICHIGAN UNIVERSITY DESIGN STANDARD FOR INTERIOR CAMPUS SIGNAGE - JANUARY 23, 2017

Guide Specification Section Interior Aluminum Doors and Frames

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

Guide Specification Section Interior Suspended Sliding Glass Doors

Product Guide Specification

2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

1.1. Any deviance from the following requirements must be approved during design by WVU Facilities Management.

INDEX OF SPECIFICATIONS SECTION F SPECIAL CONDITIONS DIVISION 1 - GENERAL REQUIREMENTS:

D. Product Certificates: Signed by manufacturers of casework certifying that products furnished comply with requirements.

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Summary of Modifications/Changes in this Update

Environmental graphics

FUZION Fused Glass Countertops - Andrew Pearson Design

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

Goudy Bold ABCDEFGHI. Interior Sign Design Guidelines. Clemson University s. Prepared by:

Product Guide Specification

PHOTOPOLYMER BRAILLE RASTER BRAILLE MOLDED BRAILLE QUICK SHIP ADA BRAILLE SIGNS. Photopolymer sign panel in a variety of thicknesses.

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

P O S T E R C A S E S D I S P L A Y C A S E S M E S S A G E B O A R D S E X H I B I T C A S E S D I R E C T O R I E S W W W. P O B L O C K I.

A. This section specifies procedural requirements for Shop Drawings, product data, samples, and other miscellaneous Work-related submittals.

SECTION MANUFACTURED CASEWORK

INTERIOR DESIGN INTENT DRAWINGS - condensed version

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

Lumicor CSI Specification Guide Open Format Section Solid Polymer Fabrication

DIVISION 1 - GENERAL REQUIREMENTS SECTION SUBMITTALS

PLAN SUBMITTAL REQUIREMENTS

A. Extent of structural precast concrete work is shown on drawings and in schedules.

SECTION Display Case Door Series 1301-CM

SECTION HOLLOW METAL DOORS AND FRAMES

SECTION PANELBOARDS

Toll-Free

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

A. Product Data: For each electrical identification product indicated.

Ash Brook Golf Course Scotch Plains, New Jersey

SECTION WOOD DOORS

SECTION LAP SIDING. A. Fiber cement lap siding, panels, single, trim, fascia, moulding and accessories.

CLEVELAND STATE UNIVERSITY

UNIFIED FACILITIES GUIDE SPECIFICATIONS

1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.

SECTION FINISH CARPENTRY

SECTION HOLLOW METAL DOORS AND FRAMES

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

Bovard Studios Inc. Section April 6, 2004 Page 1

JEFFERSON LAB TECHNICAL ENGINEERING & DEVELOPMENT FACILITY (TEDF ONE) Newport News, Virginia

Healthcare Portfolio

SECTION ELECTRICAL IDENTIFICATION

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

CLEVELAND STATE UNIVERSITY

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

Priority 3 - Toilet Rooms

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

SECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

DIVISION 12 - FURNISHINGS. Section General Discussion. Introduction

PREFOAM - PERMANENT STADIUM SEATING RISER SYSTEM FOR FLOOR MONTED SEATING PART 1 GENERAL DESCRIPTION

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

Goudy Bold ABCDEFGHI. Interior Sign Design Guidelines. Clemson University s. Prepared by:

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

w i t h Yo u r U n i v ersal Laser System

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

Piping & Equipment Identification

Priority 3 - Toilet Rooms

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

SECTION ARCHITECTURAL WOODWORK

404 Doors, Doorways, and Gates

Transcription:

SECTION 10 14 00 IDENTIFICATION SIGNS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Plastic Signs, raised character, tactile, room identification, exit door signs, and non-tactile signs. 1.02 REFERENCES A. American Society for Testing and Materials (ASTM) 1. ASTM D4802 - Poly (Methyl Methacrylate) Acrylic Plastic Sheet B. ADA Americans with Disabilities Act of 1990 as amended. 1. ADA/Standards ADA Title II Regulations and the 2010 ADA Standards for Accessible Design. C. CBC - 2013 California Building Code (CBC). 1. CBC 10 - Chapter 10, Egress Requirements 2. CBC 11B Chapter 11B, Accessibility for Public Buildings, Public Accommodations, Commercial Facilities and Publicly Funded Housing D. CFC 2013 California Fire Code. E. California Code of Regulations (CCR) 1. CCR 19-3 - Title 19, Chapter 3 F. Fed.Stnd - Federal Standard 1. Fed.Stnd 595C, Colors Used in Federal Procurement 1.03 SUBMITTALS A. Shop Drawings of each sign, indicating lettering styles and locations and overall dimensions. B. Three sample, full size, signs, of types, styles and colors specified including method of mounting. If accepted, samples may be installed in Project. C. Manufacturer's Installation Instructions D. Lettering Samples: 1-inch high, uppercase I, and O letters in each font specified, for required Quality Assurance testing. Palomar College - Escondido Health Center TI 10 14 00-1

1.04 QUALITY ASSURANCE A. Pre-Installation Conference 1. Notify Architect when signs are ready for installation. Arrange for conference at site. Do not proceed with installation until Architect's approval of specific locations and methods of attachment has been obtained. 2. Provide signs from one manufacturer, unless otherwise approved. 1.05 DELIVERY, STORAGE AND HANDLING A. Deliver products to site and protect from damage. Store until immediately prior to Notice of Completion. PART 2 - PRODUCTS 2.01 REGULATORY REQUIREMENTS A. Signage and Graphics: 1. Raised characters shall comply with CBC Section 11B-703.2 a. Depth: It shall be 1/32 inch minimum above their background and shall be sans serif uppercase and be duplicated in Braille. b. Height: It shall be 5/8 inch minimum and 2 inches maximum based on the height of the uppercase letter I. CBC Section 11B-703.2.5. c. Finish and contrast: Characters and their background shall have a non-glare finish. Character shall contrast with their background with either light characters on a dark background or dark characters on a light background. CBC Section 11B-703.5.1 d. Proportions: It shall be selected from fonts where the width of the uppercase letter O is 60% minimum and 110% maximum of the height of the uppercase letter I. Stroke thickness of the uppercase letter I shall be 15% maximum of the height of the character. CBC Section 11B-703.2.4 and 11B-703.2.6. e. Character Spacing: Spacing between individual raised characters shall comply with CBC Section 11B-703.2.7 and 11B-703.2.8. f. Format: Text shall be in a horizontal format. CBC Section 11B-703.2.9. g. Braille: It shall be contracted (Grade 2) and shall comply with CBC Sections 11B-703.3 and 11B-703.4. Braille dots shall have a domed or rounded shape and shall comply with CBC Table and Figure 11B-703.3.1. h. Mounting height: Tactile characters on signs shall be located 48 minimum to the baseline of the lowest Braille cells and 60 maximum to the baseline of the highest line of raised characters above the finish floor or ground surface. CBC Section and Figure 11B-703.3.4.1. i. Mounting location: A tactile sign shall be located per CBC Section and Figure 11B-703.4.2 as follows: 1) Alongside a single door at the latch side. 2) On the inactive leaf at double doors with one active leaf. 3) To the right of the right hand door at double doors with two active leafs. Palomar College - Escondido Health Center TI 10 14 00-2

4) On the nearest adjacent wall where there is no wall space at the latch side of a single door or at the right side of double doors with two active leafs. 5) So that a clear floor space of 18 x 18 minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position. 2. Visual characters shall comply with CBC Section 11B-703.5 and shall be 40 minimum above finish floor or ground. 3. Pictograms shall comply with CBC Section 11B-703.6. 4. Symbols of accessibility shall comply with CBC Section 11B-703.7. 5. Variable message signs shall comply with CBC Section 11B-703.8. 2.02 MANUFACTURERS A. Products of following manufacturers form basis for design and quality intended. 1. Apco Signs, Atlanta, GA. 2. Mohawk Sign Systems, Inc., Schenectady, NY. 3. Roemer Industries, Masury, OH. 4. ASI Modulex, Inc., Dallas, TX. 5. Vomar Products. 6. Nelson-Harkins Industries, Inc. 7. Mathews International Corporation 8. Vista System B. Or approved equal in accordance with Division 01 General Requirements for substitutions. 2.03 PLASTIC SIGN MATERIALS A. Tactile Plastic Sign Materials: Thermosetting high pressure laminate. B. Non-Tactile Signs: Acrylic Plastic Sheet: ASTM D4802, Category A-1, 1/4 inch overall thickness, laminated acrylic plastic sheets. 2.04 SIGN FABRICATION - GENERAL A. Plastic Signs 1. APCO IM System plaque signage system consisting of holder unit mounted to substrate, Model BH-66. 2. Materials: a. Holder: 1) Material: Integrally colored injection molded high impact UV resistant, colorfast, plastic alloy with mounting system. 2) Corners: Square Corners. 3) Edge Detail: Bevel Edge. b. Mounting: As recommended by manufacturer. c. Size: 6 x 6 d. Color: as selected by Architect. Palomar College - Escondido Health Center TI 10 14 00-3

e. Finish: as selected by Architect. 3. Insert: a. Non-Tactile signs: Integrally colored injection molded high impact plastic with computer generated photographic silkscreen process surface printing chemically bonded to self-aligning reveal insert material; insert corner same type as holder. b. ADA Tactile Signs: 1/32 thickness computer generated photo-etched rubberized surface material chemically bonded to self-aligning reveal insert material; insert corner same type as holder; silkscreen colors surface applied. B. Fasteners: As recommended by manufacturer. C. Lettering Type Style: Helvetica Regular, uppercase letters only, refer to QUALITY ASSURANCE for letter-proportion compliance. D. Colors: As selected by Architect. 2.05 ROOM IDENTIFICATION SIGNS A. Room Identification Signs: raised character, tactile plastic signs in as selected by the Architect from the manufacturer's full range of available colors. 1. ADA Tactile and Braille Signs: Thermosetting high pressure-laminate using Graphic Process Sand-Carved signs. 2. Non-Tactile Signs: Acrylic Plastic Sheet: ASTM D4802, Category A-1. B. Size: 2-1/2 inches high, minimum, by 8 inches long, with 7/8 inch high, letters minimum 1/32 inch thick, minimum 3/32 inch thick for metal signs, fully tactile, with BRAILLE indicator. 1. Provide one sign with up to 13 letters for each door. 2. Provide one sign with up to 3 numerals for each door. PART 3 - EXECUTION 3.01 EXAMINATION A. Verify that surfaces are ready to receive Work. B. Beginning of installation means installer accepts existing surfaces. 3.02 INSTALLATION A. Install signs only after surfaces are finished, install at all rooms. 1. At single-leaf doors, locate signs on wall adjacent to latch side of applicable door opening, centered horizontally within 18-inch space adjacent to latch side of door, 60 inches from finish floor to center line of sign. Mounting location shall be located so that a clear space of 18 minimum by minimum by 18 minimum, Palomar College - Escondido Health Center TI 10 14 00-4

centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position. CBC Section 11B-703.4.2. B. Mounting 1. Tactile Plastic Signs: As recommended by manufacturer. 2. Non-tactile Plastic Signs: As recommended by manufacturer. C. Clean and polish signs following manufacturer s instructions. 3.03 FIELD QUALITY CONTROL A. DSA Inspections: Signs and identifications or other information shall be field inspected after installation and approved by Division of the State Architect prior to the issuance of a final certificate of occupancy, or final approval where no certificate of occupancy is issued. The inspection shall include, but not limited to, verification that Braille dots and cells are properly spaced and the size, proportion and type of raised characters are in compliance with CBC, Section 11B-703.1.1.2. 3.04 SIGN TYPES AND SCHEDULE A. As indicated on Drawings. END OF SECTION Palomar College - Escondido Health Center TI 10 14 00-5