Split case double suction centrifugal pump. Technical data Serie: DPAS C

Similar documents
Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.

CENTRIFUGAL PUMPS FRAME MOUNT 13" FEATURES

LKH-110 Multi-Stage Centrifugal Pumps Sanitary version with multi voltage motor, complete unions, legs and shroud

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Series 80 In-Line Mounted Centrifugal Pumps

UPA 150C. 50 Hz. Applications. Submersible Borehole Pumps for Well Diameters of 150 mm (6 inches) Operating Data. Design. Designation (Example)

Submittal Data Sheet Wilo MVI - Vertical Multistage Pumps

EC centrifugal fan - RadiCal

UNISELB. Self-priming dirty water pump

Pumping of clear unfilled liquids in housing, agricultural and industrial sectors.

EC centrifugal fan - RadiCal

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

Water Circulation Pumps & Circulators PERFORMANCE CURVES. CI Pumps. FI Pumps. Taco Curve Book B

Liquid ring vacuum pumps in compact design

Side. Channel Blower APEX DARGANG MACHINERY CORPORATION

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

TPHK Series. Immersible Pump

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP.

onlinecomponents.com

AC axial compact fan

TPHK Series. Immersible Pump

EC centrifugal fan - RadiCal

AC centrifugal fan - RadiCal

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan - RadiCal

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC axial fan. sickled blades (S series)

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

3. HIWIN rotary tables TMS

TC ROTARY INDEXING TABLE: RELIABILITY FOR A LIFETIME

Low Voltage alternators - 4 pole LSA 47.2

EC centrifugal fan - RadiCal

T22. Torque transducer. Special features. Data sheet

LIVE CENTRES FACE DRIVERS

AC centrifugal fan. forward curved, single inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

EC centrifugal fan - RadiCal

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

AC axial compact fan

AC diagonal compact fan

AC centrifugal fan. backward curved

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan - RadiCal

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

CHAPTER 7 FAULT DIAGNOSIS OF CENTRIFUGAL PUMP AND IMPLEMENTATION OF ACTIVELY TUNED DYNAMIC VIBRATION ABSORBER IN PIPING APPLICATION

TABLE OF CONTENTS SERIES SPINDLES Cartridge Block Belt-Driven Motorized GILMAN SPINDLE SYSTEMS... 4 PRODUCT FEATURES...

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

Valve repair and testing technique

AC centrifugal fan. forward curved, single inlet with housing (flange)

CNC TURNING CENTRES B750 B1250

Low Voltage alternators - 4 pole LSA 46.2

TPV 1200 BTB. Variable Displacement Closed Loop System Axial Piston Compact Tandem Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 160 / 0516 / E

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. forward curved, dual inlet with housing (flange)

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Rotary Position Technology Incremental Encoders

Optical encoder MEC22 HR

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

RAY COMPACT ENERGY METER MECHANICAL

Mastering big challenges at small lot sizes easily. EMCOMat-Serie FB-3 L FB-450 MC FB-600 MC. [ means:

EC centrifugal fan. forward curved, dual inlet with housing (flange)

TYPE 3740 WET RUNNING CARTRIDGE SPLIT SEAL Technical Specification

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

TECHNICAL DATA. ErP R eady NewMotorTechnolgy. FERRIER PUMPS LTD Edinburgh Glasgow Aberdeen

PARTNER ALTERNATORS LSA 40-4 Pole

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Eccentric vibrating mill

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

EC/AC axial fans - HyBlade Ø

Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process

LSA Pole. R 726 Mains paralleling

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

.com More than a machine. Power your life

LIVE CENTRES FACE DRIVERS

Model Number Designation F- PV2R1-6 -L -R A A -42 -* Shaft Rotation. A: Upwards (Normal)

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. forward curved, single inlet with housing (flange)

EXPLODED VIEW OF KINNEY MODELS KC-5 & KC-8

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Horizontal Machining Center

Yonos PARA RS **/7.0 ipwm1 Datasheet

LENORD. +BAUER... automates motion. Magnetic incremental encoder GEL 293 for heavy duty applications. Technical Information Version 04.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

CM6200 MILLING MACHINE

[ means: One-stop shop. EMCOMAT FB-450 L / FB-600 L. Universal milling machines with Heidenhain TNC 320 or EMCO Easy Cycle

Overview Grinding Applications

Trunnion bearing housings for grinding mills FSDR.. K series

PARTNER ALTERNATORS LSA Pole

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

Transcription:

Split case double suction centrifugal pump Technical data Serie: DPAS C

Table of Contents 1 Introduction 1.1 Fields of Application... 1. Pumped Liquids... 1.3 Design... 1. Bearings... 1.5 Shaft Seal... 1. Materials... 1.7 Model key... 5 1. Motor data... 5 Specifications DPAS.1 DPAS 5-5 P... 7. DPAS 5-5 P....3 DPAS -5 P... 9. DPAS -5 P... 1.5 DPAS -3 P...11. DPAS -3 P... 1.7 DPAS 1-5 P... 13. DPAS 1-5 P... 1.9 DPAS 1-315 P... 15.1 DPAS 1-315 P... 1.11 DPAS 15-5 P... 17.1 DPAS 15- P... 1.13 DPAS 15-5 P... 19.1 DPAS -315 P....15 DPAS - P... 1.1 DPAS -5 P....17 DPAS 5-315 P... 3.1 DPAS 5- P....19 DPAS 5-5 P... 5 3 Dimensions 3.1 DPAS dimensions... 3

1 Introduction 1.1 Fields of Application Water supply and booster stations Irrigation, overhead irrigation Drainage stations Power stations Industrial water supply systems Fire fighting systems Marine applications General applications in refineries 1.5 Shaft Seal Burgmann MG1 Single Seal Unbalanced Elastomer Bellows Independent on direction of rotation p = 1 bar t = -...1 C 1. Pumped Liquids 1. Materials Thin, clean, non-aggressive and non-explosive liquids free from large solid particles or fibres. 1.3 Design Single-stage axially split casing pumps with double entry and radial impeller Double entry, closed impeller is hydraulically thrust compensated. Lower casing is in-line design, suction and discharge nozzles are on the same line Upper casing is self-aligning and it is easy to mount The NPSH values are reduced and high suction lifts are possible thanks to double suction impeller Short shaft design: For mechanical seal applications, shaft length can be reduced. Therefore, compact and rigid pumps are available Pump and motor are separate components connected to each other via flexible coupling and mounting on a base plate. Component Material Casing.5 / GJL-5 Impeller.5 / GJL-5 Shaft 1.1 / X Cr 13 Casing wear ring.15.1 / G-Cu Sn 1 Gland.7 / GJS-5 Bearing housing and cover.5 / GJL-5 1. Bearings For pumps groups A, B and C, there are ball bearings at the both dead and drive end of the pump. see For pump groups D, E and F, a cylindrical roller bearing is installed at the drive end of the pump and there is a ball bearing at the dead end of the pump. see

1.7 Model key The pumps are designated as according to the following table DPAS C 5 5 DN1- DN5- P 37kW DPAS Pump series horizontal spilt case C Cast iron version 5 Size 5 Nominal diameter impeller Diameter impeller DN1- Suction connection DN5- Discharge connection P pole version 37kW P 1. Motor data B5 flanged, IP 55 and according to IEC electric motors are used for DPAS series pumps. The motors are suitable for inverter usage according IEC 3. Table 1: Motor data 5Hz pole Power Inom [A] Ia/In Cos phi Eff [%] Motor voltage [V] n [rpm] IEC connection mass [kg] 1,5 3,3,,7 1,3 3/ 9 9L 17,5,,,3,9 3, 3/ 9L 1 3 5, 9,,, 3/ 5 1L 7,7 9,5,7 5, /9 95 11M 31 7 5,5 1, 9,1,7 7 /9 935 13S 7 7 7,5 13, 9,1,9,1 /9 95 13M 53 7 11 19,,1,9 9, /9 95 1M 7 71 15 5,7,,9 9,3 /9 935 1L 71 1,5 31,,1,9 9,9 /9 95 1L 9 71 37,5 7,,9 91,3 /9 9 1M 11 77 3 55,1,,5 9 /9 9 L 1 37 5,91 9,5 /9 9 L 179 5,1,1,5 9,9 /9 9 5M 51 1 Sound pressure level db(a) 5

Table : Motor data 5Hz pole Power Inom [A] Ia/In Cos phi Eff [%] Motor voltage [V] n [rpm] IEC connection mass [kg],5,,,7 7 3/ 115 71M 9 5,37,95,,71 7,1 3/ 1 71M 9,5 5,55 1,5 5,71 7,1 3/ 15 M 1 9, 1,9 5,5,7 79, 3/ 13 M 1,5 9 1,1, 7,3 1, 3/ 13 9L 17,5 5 1,5 3, 3,,, 3/ 1 9L 1 55, 5,73,3 3/ 1 1L 5 5 3, 7,5,7 5,5 3/ 135 1L 5,,,79, /9 1 11M 3 5 5,5 11,3,7,7 7,7 /9 1 13M 55 1 7,5 15 9,5,1,7 /9 1 13M 57 1 11,,79 9, /9 1 1M 77 3 15,,3 9, /9 1 1L 9 3 1.5 35,1 7,5, 91, /9 155 1M 1 9, 7,5, 91, /9 1 1L 135 9 3 55,7,5 9,3 /9 17 L 1 7 37 9,, 9,7 /9 1 5M 71 5 3,3,3 93,1 /9 1 5M 9 71 Sound pressure level db(a)

Specifications DPAS.1 DPAS 5-5 P NPSHr P - POWER Hm - TOTAL HEAD 15 1 5 1 DPAS 5-5 5 1 15 5 3 35 5 55 ø 5 % 5 7 ø 37 ø ( US.GPM ) Ref.No: 131199 15 min 5 ø 1 3 5 7 ( m³ / h ) 9 1 5 5 5 1 15 (l/sec) 5 5 ø ø 3 1 55 ø 37 5 ø ( Feet ) 7 5 3 1 1 15 1 5 7 Curves are valid for C clean water. Tolerance ISO 99 Table 3: General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 5-5 7,5 15 517D 5-5 37 5,5 15 517D37 5-5 15 517D

. DPAS 5-5 P NPSHr P - POWER Hm - TOTAL HEAD 11 1 9 7 5 3 5 3 1 DPAS 5-5 Ref.No: 131 95 min 5 1 3 (l/sec) 5 1 ( US.GPM ) 1 3 5 7 ø % 5 ø 37 ø 55 5 1 (m³/h) 15 5 7 ø ø 5 55 ø37 ø ø 35 3 5 15 1 7 5 3 1 3 1 Table : General data Curves are valid for C clean water. Tolerance ISO 99 Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 5-5 55 15 515D 5-5 37 5 15 515D37 5-5 37 15 515D

.3 DPAS -5 P NPSHr P - POWER Hm - TOTAL HEAD 3 1 1 1 1 DPAS -5 Ref.No: 1311 15 min 5 (m³/h) 1 1.5 1.5 1.5 (US.GPM) 1 3 ø 7 ø5 ø % 5 55 1 (l/sec) 3 ø 5 7 ø 7. 7 5 ø5 ø7 ø7 5 ( Feet ) 9 7 5 1 1 1 ( Feet ) 5 9 Curves are valid for C clean water. Tolerance ISO 99 Table 5: General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number -5 7 11 15 17D7-5 5 7,5 15 17D5-5 5,5 15 17D

. DPAS -5 P 1 11 DPAS -5 1 3 5 7 9 ø 7 % (US.GPM) 5 55 5 Ref.No: 131 95 min 5 7 7. 7 1 11 35 1 NPSHr P - POWER Hm - TOTAL HEAD 1 9 7 5 1 ø5 ø ø 5 1 15 (m³/h) 5 3 5 15 1 1 1 3 5 (l/sec) 7 1 ø 7 ø 3 1 5 ø 5 ø7 Curves are valid for C clean water. Tolerance ISO 99 Table : General data Model Impeller diameter [mm] P [kw] Motormass [kg] Pump mass [kg] Part number -5 7 9 15 15D7-5 5 15 15D5-5 5 15 15D

.5 DPAS -3 P NPSHr P - POWER Hm - TOTAL HEAD Table 7: General data 5 3 1 3 1 5 3 1 DPAS -3 Ref.No: 1313 15 min 5 ( US.GPM ) 1 3 5 %3 ø 3 5 5 ø 3 ø 3 ø3 ø ø 1 (m³/h) 1 5 1 15 5 3 (l/sec) 55 5 5.7 5 ø 55 ø 3 ø3 ø ø Curves are valid for C clean water. Tolerance ISO 99 ø3 ø3 ø 3 1 1 1 1 3 1 ( Feet ) 15 1 5 11 Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number -3 3 15 717D3-3 3 1,5 15 717D3-3 3 15 15 717D3-3 3 11 15 717D3-3 7,5 15 717D

. DPAS -3 P 1 NPSHr P - POWER Hm - TOTAL HEAD 1 1 1 1 1 DPAS -3 Ref.No: 131 95 min 5 ( Feet ) 1 (US.GPM) 1 1 1 %3 ø 3 5 5 ø3 ø 3 ø 3 ø ø 55 1 (m³/h) 3 1 (l/ sec) 1 1 ø ø3 5 5.7 5 ø ø 55 ø 3 ø3 ø 3 ø3 5 3 1 ( Feet ) 3 1 Curves are valid for C clean water. Tolerance ISO 99 Table : General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number -3 3 11 15 715D3-3 9 15 715D -3 15 715D

.7 DPAS 1-5 P NPSHr P - POWER Hm - TOTAL HEAD 3 5 15 1 5 1 DPAS SPLT 1-5 1-5 1 3 5 7 9 %5 ø 7 7 ø5 ø3 ø ( US.GPM ) Ref.No: 1315 15 min 5 1 11 1 5 1 15 (m³/h) 5 9 7 5 3 1 3 5 ( l / sec ) 7 ( Feet ) 5 15 ø7 3 1 ø 1 5 ø. 7 ø 3 ø 5 ø7 1 13 Table 9: General data Curves are valid for C clean water. Tolerance ISO 99 Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 1-5 7 15 1 117D7 1-5 5 11 1 117D5 1-5 3 7,5 1 117D3 1-5 5,5 1 117D

. DPAS 1-5 P 1 NPSHr P - POWER Hm - TOTAL HEAD 1 15 DPAS 1-5 1 1 1 1 1 1 %5 7 ø 7. 1 5 ø5 ø 3 ø (US.GPM) ø Ref.No: 131 95 min 5 1 3 (m³/h) 5 35 3 5 15 1 1 (l/sec) 1 1 ø 7 ( Feet ) 1 ø 3 1 ø 3 ø 5 ø7 15 1 5 Curves are valid for C clean water. Tolerance ISO 99 Table 1: General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 1-5 5 9 1 115D5 1-5 3 1 115D3 1-5 55 1 115D

.9 DPAS 1-315 P 5 5 DPAS 1-315 (US.GPM) 1 3 5 7 9 1 ø 35 ø 33 %5 7.1 Ref.No: 1317 15 min 5 11 1 13 1 ( Feet ) 15 NPSHr P - POWER Hm - TOTAL HEAD 35 3 5 3 1 5 3 1 ø35 ø95 ø5 ø7 ø 5 1 15 (m³/h) 5 3 Q-CAPACITY ø95 ø5 ø7 ø 1 3 5 (l/sec) 7 ø 7 ø35 ø33 ø 35 ø 35 1 13 1 11 1 9 7 5 3 1 15 1 5 Curves are valid for C clean water. Tolerance ISO 99 Table 11: General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 1-315 35 37 33 117D35 1-315 33 3 33 117D33 1-315 35 3 33 117D35 1-315 95 33 117D95 1-315 5 1,5 33 117D5 1-315 7 15 33 117D7 1-315 15 33 117D 15

.1 DPAS 1-315 P 1 NPSHr P - POWER Hm - TOTAL HEAD 1 (m ) 15 1 13 1 11 1 9 (KW ) 1 DPAS 1-315 1 1 1 1 1 %5 ø35 ø95 ø5 ø7 ø ( US.GPM ) 5 7 Ref.No: 131 95 min 5 1 3 (m³/h) 5 5 ( Feet ) 5 35 3 (HP ) 1 (l/sec) 1 1 1 ø ø35 3 1 7 7.3 7 ø ø7 7 ø 95 ø 5 ø 35 1 Curves are valid for C clean water. Tolerance ISO 99 Table 1: General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 1-315 35 5 33 115D35 1-315 11 33 115D

.11 DPAS 15-5 P NP S Hr P - P OWE R Hm - T OTAL HE AD 3 ( m ) 5 15 1 3 1 R ef.no:. S P L T 15-5 15 min 5 DPAS 15-5 (US.GPM) 1 1 1 1 1 ø 7 ø 5 ø ø5 ø7 %5 7 ø 7 ø5 1 3 (m³/h) 5 1 7 ( Feet ) 1 ( l / sec ) 1 1 ( m ) 1 3 ø 7 ø 7 1.5 ø ø 5 Curves are valid for C clean water. Tolerance ISO 99 7 ø7 9 5 ( HP ) 3 1 17 Table 13: General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 15-5 7 3 1517D7 15-5 5 1517D5 15-5 1,5 1517D 15-5 5 15 1517D5 15-5 7 11 1517D7

.1 DPAS 15- P NPSHr P - POWER Hm - TOTAL HEAD (m ) 7 5 3 15 1 5 Ref.No: 13111 DPAS 15-1 min 5 Q-CAPACITY(US.GPM) 5 1 15 5 ø5 ø 3 ø 1 ø 39 ø 37 ø 35 %5 7 Q-CAPACITY 3 1 3 5 (m³/h) 7 1 1 (l/sec) 1 1 (m ) 1 ø 35 ø5 1.1 7 ø5 ø 3 ø1 ø 39 ø37 ø 35 1 1 1 1 1 15 1 5 3 1 1 Table 1: General data Curves are valid for C clean water. Tolerance ISO 99 Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 15-5 13 515 1517D5 15-3 11 515 1517D3 15-1 9 515 1517D1 15-39 515 1517D39 15-37 515 1517D37

.13 DPAS 15-5 P NPSHr P - POWER Hm - TOTAL HEAD 1 11 (m ) 1 9 7 5 1 Ref.No: 1311 DPAS 15-5 1 min 5 (US.GPM) 5 1 15 5 1 3 (m³/h) 5 (m ) 1 ø 5 ø53 ø5 ø7 ø %5 5 7 1 (l/sec) 1 1 ø 7.3 ø 7 ø ø5 7 ø53 ø5 ø5 3 5 15 1 3 1 19 Curves are valid for C clean water. Tolerance ISO 99 Table 15: General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 15-5 5 15 59 15A17D5 15-5 53 1 59 15A17D53 15-5 5 13 59 15A17D5 15-5 7 11 59 15A17D7

.1 DPAS -315 P NPSHr P - POWER Hm - TOTAL HEAD 3 5 15 1 1 DPAS -315 Q-CAPACITY Ref.No: 13113 1 min 5 (US.GPM) 5 1 15 5 3 5 13 %5 (m ) 5 7 1 35 ø 5 7.3 11 ø53 ø 5 ø7 ø ø 1 3 5 (m³/h) Q-CAPACITY ø 7 ø5 1 1 1 1 (l/sec) (m ) 1 ø ø 5 3 1 ø53 7 ø5 1 9 7 5 1 1 Curves are valid for C clean water. Tolerance ISO 99 Table 1: General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number -315 5 55 17D5-315 53 55 55 17D53-315 7 37 55 17D7-315 3 55 17D

.15 DPAS - P NPSHr P - POWER Hm - TOTAL HEAD (m ) 7 5 Table 17: General data DPAS - 1 Q-CAPACITY(US.GPM) 3 Ref.No: 1311 1 min 5 3 1 1 ø 3 ø 1 ø 39 ø37 ø 35 %5 7 1 3 5 7 (m³/h) 9 1 5 5 1 15 (l/sec) 5 (m ) 1 ø 35 ø 3 3.5 ø37 ø 35 Curves are valid for C clean water. Tolerance ISO 99 3 3 ø 39 ø1 ø 3 1 1 1 1 1 3 1 1 Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number - 3 1 5 17D3-1 13 5 17D1-39 11 5 17D39-37 9 5 17D37-35 9 5 17D35

.1 DPAS -5 P 1 DPAS -5 Q-CAPACITY(US.GPM) 1 3 5 Ref.No: 13115 1 min 5 NPSHr P - POWER Hm - TOTAL HEAD 11 (m ) 1 9 7 5 3 1 (m ) 1 1 ø 5 ø 53 ø 5 ø 7 ø %5 7 1 (m³/h) 1 Q-CAPACITY 5 1 15 5 3 (l/sec).3 ø ø ø7 ø5 ø 53 ø 5 ø 5 35 3 5 15 5 3 1 Table 1: General data Curves are valid for C clean water. Tolerance ISO 99 Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number -5 15 7 A17D

.17 DPAS 5-315 P NPSHr P - POWER Hm - TOTAL HEAD 35 3 5 15 15 1 5 Ref.No: 1311 SPLT 5-315 1min 5 ( US.GPM ) 1 3 5 1 (m³/h) 1 1 DPAS 5-315 ø 33 ø 31 ø 9 ø 7 % 7 5 1 15 5 3 (l/sec) 3 5 ø7 ø7 5.1 5 3 ø 9 7 ø31 ø 33 ø33 ( Feet ) 1 11 1 9 7 5 15 1 5 3 1 3 Curves are valid for C clean water. Tolerance ISO 99 Table 19: General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 5-315 33 11 517D33 5-315 31 9 517D31 5-315 9 517D9 5-315 7 55 517D7

.1 DPAS 5- P NPS Hr P - POWE R Hm - TOTAL HE AD 3 3 1 R ef.no: 13117 5-15 min 5 (US.GPM) 1 3 5 7 5 1 (m³/h) 15 1 3 (l/sec) 5 7 ø5 % 7 3 ( m ) ( Feet ) ø 3 5 5.1 5 ø 1 3 1 ø 5 ø 3 1 1 5 1 ø5 ø35 3 1 DPAS ø37 ø35 ø35 ø ø3 ø37 ø1 ø 3 7 ø5 1 1 1 ( HP ) 3 1 Table : General data Curves are valid for C clean water. Tolerance ISO 99 Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 5-3 5 7 517D3 5-1 7 517D1 5-15 7 517D 5-3 1 7 517D3 5-37 13 7 517D37 5-35 11 7 517D35

.19 DPAS 5-5 P NPS Hr P - POWE R Hm - TOTAL HE AD 3 3 1 R ef.no: 13117 5-15 min 5 (US.GPM) 1 3 5 7 5 1 (m³/h) 15 1 3 (l/sec) 5 7 ø5 % 7 3 ( m ) ( Feet ) ø 3 5 5.1 5 ø 1 3 1 ø 5 ø 3 1 1 5 1 ø5 ø35 3 1 DPAS ø37 ø35 ø 35 ø ø 3 ø37 ø1 ø 3 Curves are valid for C clean water. Tolerance ISO 99 7 ø5 1 1 1 ( HP ) 3 1 5 Table 1: General data Model Impeller diameter [mm] P [kw] Pump mass [kg] Part number 5-5 517 5 5 5A17D517 5-5 5 5A17D 5-5 15 5 5A17D 5-5 5 1 5 5A17D5

3 Dimensions 3.1 DPAS dimensions Figure 1: Drawing DPAS Table : Dimensions DPAS [mm] Model Gr. 5-5 A DN1 - -5 B DN15 - -3 B DN15-1-5 B DN15-1-315 C DN15-15- D DN15-15-5 C DN - 15-315 D DN - 15- D DN - 15-5 D DN - -315 D DN5 -PN1 - D DN5 -PN1-5 E DN5 -PN1 5-315 E DN3 -PN1 5- E DN3 -PN1 5-5 E DN3 -PN1 35- F DN -PN1 DNs DNd Lp e f h1 h Hp A B G b m1 m n1 n s l d DN5- DN- DN- DN1- DN1- DN15- DN15- DN15- DN15- DN15- DN- DN- DN- DN5- DN5- DN5- DN35-55 195 5 115 5 5 5 51 7 19 35 1 57 1 95 1 5 3 5 3 19 33 1 3 57 1 95 315 135 55 35 3 19 33 1 3 55 3 315 315 155 55 35 7 5 33 1 3 15 355 355 15 55 3 3 9 9 3 35 35 3 11 9 3 39 3 1 7 5 5 1 37 3 5 3 11 5 5 5 3 3 1 35 35 75 1 3 7 5 3 11 9 3 39 3 1 5 35 1 37 3 5 3 11 5 9 3 39 73 1 37 3 5 3 11 5 9 3 39 5 5 7 55 5 15 1 37 3 5 55 3 11 5 75 315 1 3 5 73 5 3 5 1 3 3 5 3 11 5 75 315 1 3 5 79 55 5 95 1 3 3 5 3 11 5 337 5 7 55 5 15 1 39 5 55 1 37 95 5 5 55 5 9 1 1 5 55 1 337 5 5 5 5 55 5 1 1 39 5 55 1 37 95 55 95 5 11 1 1 5 55 1 1 35 55 1 95 11 5 11 15 5 1

7

dp pumps P.O. Box AA Alphen aan de Rijn t +31 17 3 f +31 17 9 3 dp@dp.nl www.dp.nl 1/1 97 Subject to modifications. Digital alteration or publishing of the content of this document without prior notice is strictly prohibited. Permission for use, copying and distribution of this document are published by DP-Industries is granted on the condition that no part of the document is used for information or commercial purposes outside of the DP-industries organisation or one of its recognised dealerships.