Low Voltage alternators - 4 pole LSA 46.2
|
|
- Horace Wilcox
- 5 years ago
- Views:
Transcription
1 Low Voltage alternators - 4 pole 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Electrical and mechanical data 379 en /h 1-8-POWER-8
2 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz SPECIALLY ADAPTED TO APPLICATIONS The alternator is designed to be suitable for typical generator applications, such as: backup, marine applications, rental, telecommunications, etc. COMPLIANT WITH INTERNATIONAL STANDARDS The alternator conforms to the main international standards and regulations: - IEC 634, NEMA MG , ISO 828-3, CSA / UL 1446 (UL 4 on request), marine regulations, etc. It can be integrated into a CE marked generator. The is designed, manufactured and marketed in an ISO 91 environment and ISO 141. TOP OF THE RANGE ELECTRICAL PERFORMANCE Class H insulation. Standard 12-wire re-connectable winding, 2/3 pitch, type no. 6. Voltage range Hz: 22 V - 24 V and 38 V - 41 V (44 V). Voltage range 6 Hz: 28 V - 24 V and 38 V - 48 V. High efficiency and motor starting capacity. Other voltages are possible with optional adapted windings: - Hz: 44 V (no. 7), V (no. 9), V (no. 22), 6 V (no. 23), 69 V (no. or 2). - 6 Hz: 38 V and 416 V (no. 8), 6 V (no. 9). R 791 interference suppression conforming to standard EN 11 group 1 class B standard for European zone (CE marking). EXCITATION AND REGULATION SYSTEM SUITED TO THE APPLICATION Excitation system Regulation options Volage regulator SHUNT AREP PMG Current transformer for paralleling Mains paralleling 3-phase sensing 3-phase sensing for mains paralleling unbalanced Remote voltage potentiometer R2 Std R4 Option Std Std C.T. R726 R731 R734 DC Option Option Option C.T. included included contact factory Voltage regulator accuracy ±.% : possible mounting PROTECTION SYSTEM SUITED TO THE ENVIRONMENT The is IP 23. Standard winding protection for clean environments with relative humidity 9 %, including indoor marine environments. Options : Filters on air inlet : derating %. Filters on air inlet and air outlet (IP 44) : derating %. Winding protections for harsh environments and relative humidity greater than 9%. Space heaters. Thermal protection for winding and shields. REINFORCED MECHANICAL STRUCTURE USING FINITE ELEMENT MODELLING Compact and rigid assembly to better withstand generator vibrations. Steel frame. Cast iron flanges and shields. Twin-bearing and single-bearing versions designed to be suitable for engines on the market. Half-key balancing. Sealed for life ball bearings, regreasable bearings (optional). ACCESSIBLE TERMINAL BOX PROPORTIONED FOR OPTIONAL EQUIPMENT Easy access to the voltage regulator and to the connections. Possible inclusion of accessories for paralleling, protection and measurement. 12-way terminal block for voltage reconnection. 2 Ref : 379 en 1-8-POWER-8
3 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz General characteristics Insulation class H Excitation system SHUNT AREP or PMG Winding pitch 2/3 (N 6) AVR type R 2 R 4 Number of wires 12 Voltage regulation (*) ±. % ±. % Protection IP 23 Short-circuit current - 3% (3 IN) : s Altitude m Totale Harmonic distortion THD (**) no load < 2.% - on load < 2.% Overspeed 22 min -1 Waveform: NEMA = TIF (**) < Air flow.43 m 3 /s (Hz) /.1 (6Hz) (*) Steady state. (**) Total harmonic distortion between phases, no-load or on-load (non-distorting) Ratings Hz - 1 R.P.M. kva / kw - P.F. =.8 Duty/T C Continuous duty/4 C Continuous duty/4 C Stand-by/4 C Stand-by/27 C Class/T K H/12 K F/ K H/1 K H/163 K Phase 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. Y 38V 4V 41V 44V 38V 4V 41V 44V 38V 4V 41V 44V 38V 4V 41V 44V 22V 23V 24V 23V 22V 23V 24V 23V 22V 23V 24V 23V 22V 23V 24V 23V YY 22V 22V 22V 22V 46.2 kva kw M kva kw kva kw kva kw kva kw Ratings 6 Hz - 18 R.P.M. kva / kw - P.F. =.8 Duty/T C Continuous duty/4 C Continuous duty/4 C Stand-by/4 C Stand-by/27 C Class/T K H/12 K F/ K H/1 K H/163 K Phase 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. Y 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 22V 24V 24V 22V 24V 24V 22V 24V 24V 22V 24V 24V YY 28V 22V 24V 28V 22V 24V 28V 22V 24V 28V 22V 24V 46.2 kva kw M kva kw kva kw kva kw kva kw Ref : 379 en POWER-8
4 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Efficiencies Hz - P.F.: 1 / P.F.: P.F. : P.F. : P.F. : P.F. : kVA M 9 : 1 P.F P.F. : kVA 9.7 P.F. : P.F. : kVA kVA P.F. : P.F. : kVA Reactances (%). Time constants (ms) - Class H / 4 V M Kcc Short-circuit ratio Xd Direct-axis synchro. reactance unsaturated Xq Quadrature-axis synchro. reactance unsaturated T do No-load transient time constant X d Direct-axis transient reactance saturated T d Short-circuit transient time constant X d Direct-axis subtransient reactance saturated T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated Xo Zero sequence reactance unsaturated X2 Negative sequence reactance saturated Ta Armature time constant Other class H/4 V data io (A) No-load excitation current (SHUNT/AREP or PMG) ic (A) On-load excitation current (SHUNT/AREP or PMG) uc (V) On-load excitation voltage (SHUNT/AREP or PMG) ms Response time ( U = 2% transient) kva Start ( U = 2% cont. or % trans.) SHUNT kva Start ( U = 2% cont. or % trans.) AREP % Transient U (on-load 4/4) SHUNT - P.F.:.8 LAG % Transient U (on-load 4/4) AREP - P.F.:.8 LAG W No-load losses W Heat dissipation Ref : 379 en 1-8-POWER-8
5 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Transient voltage variation 4V - Hz Load application (SHUNT excitation) Load application (AREP or PMG excitation) 2 % M 2 % M kva kva kva at φ.8 power factor kva at φ.8 power factor Load rejection (SHUNT excitation) Load rejection (AREP or PMG excitation) 2% M 2% M % Voltage rise 2 1 % Voltage rise kva kva kva at φ.8 power factor kva at φ.8 power factor Motor starting (SHUNT excitation) Motor starting (AREP or PMG excitation) 3% M 3% M % kVA 229 kva at φ.6 power factor locked rotor kVA kva at φ.6 power factor locked rotor 1 ) For a starting P.F. other than.6, the starting kva must be multiplied by K = Sine P.F. /.8 Calculation example for a different P.F. : Starter motor kva calculated at.4 P.F. = 2 kva Sin P.F..4 =.916 K = 1.14 kva corrected = 229 kva Voltage dip corresponding to = 12 %. 2 ) For voltages other than 4V (Y), 23V ( ) at Hz, then kva must be multiplied by (4/U) 2 or (23/U) 2. Ref : 379 en 1-8-POWER-8
6 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Efficiencies 6 Hz - P.F.: 1 / P.F.: P.F. : P.F. : P.F. : P.F. : kVA M 9 P.F. : P.F. : kVA 9 P.F. : P.F. : kVA 9.7 P.F. : P.F. : kVA kVA Reactances (%). Time constants (ms) - Class H / 48 V M Kcc Short-circuit ratio Xd Direct-axis synchro. reactance unsaturated Xq Quadrature-axis synchro. reactance unsaturated T do No-load transient time constant X d Direct-axis transient reactance saturated T d Short-circuit transient time constant X d Direct-axis subtransient reactance saturated T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated Xo Zero sequence reactance unsaturated X2 Negative sequence reactance saturated Ta Armature time constant Other class H/48 V data io (A) No-load excitation current (SHUNT/AREP or PMG) ic (A) On-load excitation current (SHUNT/AREP or PMG) uc (V) On-load excitation voltage (SHUNT/AREP or PMG) ms Response time ( U = 2% transient) kva Start ( U = 2% cont. or % trans.) SHUNT kva Start ( U = 2% cont. or % trans.) AREP % Transient U (on-load 4/4) SHUNT - P.F.:.8 LAG % Transient U (on-load 4/4) AREP - P.F.:.8 LAG W No-load losses W Heat dissipation Ref : 379 en 1-8-POWER-8
7 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Transient voltage variation 48V - 6 Hz Load application (SHUNT excitation) Load application (AREP or PMG excitation) 2 % 2 M 2 % 2 M kva kva kva at φ.8 power factor kva at φ.8 power factor Load rejection (SHUNT excitation) Load rejection (AREP or PMG excitation) 2% M 2% M 2 2 % Voltage rise 1 % Voltage rise kva kva at φ.8 power factor kva kva at φ.8 power factor Motor starting (SHUNT excitation) Motor starting (AREP or PMG excitation) 3% M 3% M % kva 229 kva at φ.6 power factor locked rotor kVA kva at φ.6 power factor locked rotor 1 ) or a starting P.. ot er t an.6 t e starting kv A st e ltiplied Sine.. P.8 Calculation example for a different P.F. : Starter motor kva calculated at.4 P.F. = 2 kva Sin P.F..4 =.916 K = 1.14 kva corrected = 229 kva Voltage dip corresponding to = %. 2 ) or oltages ot er t an 48V ( ) 277V ( ) 24V ( ) at 6 H t en kva st e ltiplied (48 U) 2 or (277 U) 2 or (24 U) 2. Ref : 379 en POWER-8
8 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz 3-phase short-circuit curves at no load and rated speed (star connection Y) Symmetrical Asymmetrical Current (A) AREP or PMG SHUNT 1 time (ms) M Symmetrical Asymmetrical Current (A) AREP or PMG SHUNT 1 time (ms) Symmetrical Asymmetrical Current (A) AREP or PMG SHUNT 1 time (ms) Influence due to connection Curves shown are for star (Y) connection. For other connections, use the following multiplication factors: - Series delta : current value x Parallel star : current value x 2 8 Ref : 379 en 1-8-POWER-8
9 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz 3-phase short-circuit curves at no load and rated speed (star connection Y) AREP or PMG Symmetrical Asymmetrical Current (A) SHUNT 1 time (ms) AREP or PMG Symmetrical Asymmetrical Current (A) SHUNT 1 time (ms) Influence due to short-circuit Curves are based on a three-phase short-circuit. For other types of short-circuit, use the following multiplication factors. 3-phase 2-phase L/L 1-phase L/N Instantaneous (max.) Continuous Maximum duration (AREP/PMG) sec. sec. 2 sec. Ref : 379 en POWER-8
10 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Single bearing dimensions AH 3 Xg L LB 33 A to t inal A to g lato tan a a l o tp t Optional a l o tp t Ø P 27 Ø N Ø BX Ø 2 77 PMG optional Ø 23 IA t 2 a o n on Ø M Ø AIR OUTLET 2 ol Ø 2 7 AIR INLET 23 A to otating io 7 27 IA t X E p on Ø U Dimensions (mm) and weight Coupling Type L without PMG LB Xg C Weight (kg) Flex plate 11 1/ Flange S.A.E 3 X M Flange S.A.E 2 X Flange S.A.E 1 X X Flange S.A.E 1/2 X Flange (mm) Flex plate (mm) S.A.E. P N M S R CF S.A.E. BX U X Y AH 3 7*/ */368 24*/ / */ */368 24*/ */ */368 24*/17 1/ * : dimensions M Xr Ø 7 Ø Ø 4(46.2 M) Ø 6(46.2 L) Ø 11 Lr Ø 12 Ø 11 Ø 1 Ø 7 Torsional analysis data Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm 2 ): (4J = MD 2 ) Flange S.A.E. 11 1/2 Flange S.A.E. 14 Type Xr Lr M J Xr Lr M J M NOTE : Dimensions are for information only and may be subject to modifications. Contractuel 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. Ref : 379 en 1-8-POWER-8
11 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Two bearing dimensions 1 ol M Xg L LB A to t inal A to g lato tan a a l o tp t 68 1 Optional a l o tp t Ø P Ø Ø 7 1 Ø PMG optional Ø AIR OUTLET 6 B 14 BB 6 ol Ø 21 AIR I LET 23 A to otating io M IA t 12 E a o n on Ø 3 22 Dimensions (mm) and weight Type L without PMG LB P C BB B R Xg Weight (kg) M Xr Ø 7 Ø 8 Ø Ø 4(46.2 M) Ø 6(46.2 L) Lr Ø 11 Ø 12 Ø 11 Ø 1 Ø 7 Torsional analysis data Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm 2 ): (4J = MD 2 ) Type Xr Lr M J M NOTE : Dimensions are for information only and may be subject to modifications. Contractuel 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. Ref : 379 en POWER-8
12 Contact en / a - This document is the property of Moteurs Leroy-Somer, it can not be reproduced in any form without prior written authorization. Moteurs Leroy-Somer reserves the right to modify the design, technical specifications and dimensions of the products shown in this document. The descriptions cannot in any way be considered contractual. Moteurs Leroy-Somer SAS - RCS ANGOULÊME - Capital de POWER-8
Low Voltage alternators - 4 pole LSA 47.2
Low Voltage alternators - 4 pole 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Electrical and mechanical data 3782 en - 214.1 / h 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz SPECIALLY ADAPTED TO APPLICATIONS The alternator
More informationPARTNER ALTERNATORS LSA 40-4 Pole
23 kva - 50 Hz 12,5 28 kva - 60 Hz 4250 en - 2011.03 / c PARTNER ALTERNATORS LSA 40-4 Pole Electrical and mechanical data SPECIALLY ADAPTED TO APPLICATIONS The LSA 40 alternator is designed to be suitable
More informationLSA Pole. R 726 Mains paralleling
498 en-.27 / a Alternators LSA.2-4 Pole Electrical and mechanical data LSA.2-4 Pole SPECIALLY ADAPTED FOR APPLICATIONS The LSA.2 alternator is designed to be suitable for typical generator set applications,
More informationPARTNER ALTERNATORS LSA Pole
90 16 kva - 0 Hz 1 6 kva - 60 Hz 38 en - 11.04 / g PARTNER ALTERNATORS LSA 44.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 44.2 alternator is designed to be suitable
More informationTAL 049 Low Voltage Alternator - 4 pole
TAL 049 Low Voltage Alternator - 4 pole 730 to 1000 kva - 50 Hz / 915 to 1250 kva - 60 Hz Electrical and mechanical data Adapted to needs The TAL alternator range is designed to meet the needs of general
More informationTAL 047 Low Voltage Alternator - 4 pole
TAL 047 Low Voltage Alternator - 4 pole 4 to 660 kva - 50 Hz / 5 to 825 kva - 60 Hz Electrical and mechanical data Adapted to needs The TAL alternator range is designed to meet the needs of general applications
More informationLSA R & LSA H 49.1 Low Voltage Alternators - 4 pole
LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole 30 to 30 kva - 0 Hz / 420 to 63 kva - 60 Hz Electrical and mechanical data Adapted to applications LSA R and LSA H alternators are enclosed alternators
More informationTAL 044 Low Voltage Alternator - 4 pole
TAL 044 Low Voltage Alternator - 4 pole Three-phase 70 to 65 kva - 50 Hz / 88 to 206 kva - 60 Hz Dedicated single-phase 57 to 82 kva - 50 Hz / 80 to 25 kva - 60 Hz Electrical and mechanical data TAL 044
More informationTime constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)
Alternators: LSA 5, XL8 Ratings 5 Hz 5 rpm kva 66 V 4 poles kva / kwe - Cos φ =,8 3 phase Duty / Ambient Continuous duty (BR) / 4 C PR* / 4 C PR* / 7 C Temperature Rise Class.H/5 K Class.F/5 K 5 K 63 K
More informationS4L1S-D4 Wdg.17 - Technical Data Sheet
- Technical Data Sheet Standards STAMFORD industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000,
More informationS4L1D-G41 Wdg Technical Data Sheet
- Technical Data Sheet Standards Stamford industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000,
More informationS0L1-J1 - Technical Data Sheet
S0L1-J1 - Technical Data Sheet Standards Stamford industrial alternators meet the requirements of the relevant parts of the IEC EN 60034 and the relevant section of other international standards such as
More informationPI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT
- Winding 07 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 34 and the relevant sections of other national and international standards
More informationPI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT
- Winding 28 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards
More informationWDG 51 - Technical Data Sheet
MV 804 S WDG 51 - Technical Data Sheet FRAME MV 804 S SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international
More informationWDG 12 - Technical Data Sheet
LV 804 W WDG 12 - Technical Data Sheet FRAME LV 804 W SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international
More informationWDG 12 - Technical Data Sheet
LV 804 R WDG 12 - Technical Data Sheet FRAME LV 804 R SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international
More informationPI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT
- Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards
More informationPI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT
- Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards
More informationPI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT
- Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards
More informationPI734C - Technical Data Sheet
PI734C - Technical Data Sheet PI734C SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
More informationWDG 61 - Technical Data Sheet
HV 804 W WDG 61 - Technical Data Sheet FRAME HV 804 W SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international
More informationPI734A - Technical Data Sheet
PI734A - Technical Data Sheet PI734A SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
More informationWDG 83 - Technical Data Sheet
HV 804 R WDG 83 - Technical Data Sheet FRAME HV 804 R SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international
More informationWDG 07 - Technical Data Sheet
LV 804 S WDG 07 - Technical Data Sheet FRAME LV 804 S SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections
More informationWDG 12 - Technical Data Sheet
LV 804 T WDG 12 - Technical Data Sheet FRAME LV 804 T SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections
More informationALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx
ALTERNATOR TECHNICAL DESCRIPTION LSA 53.2 XL3 / 4p LS Reference: 3_66 Date: 426 V4.5G 9/26 Chargé d'affaire : Karthikeyan GN Moteurs LeroySomer +33 ()2 38 6 42 xx Electric Power Generation Orleans prenom.nom@leroysomer.com
More informationWDG 71 - Technical Data Sheet
HV 804 R WDG 71 - Technical Data Sheet FRAME HV 804 R SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections
More informationWDG 12 - Technical Data Sheet
LV 804 S WDG 12 - Technical Data Sheet FRAME LV 804 S SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections
More informationWDG 13 - Technical Data Sheet
LV 804 T WDG 13 - Technical Data Sheet FRAME LV 804 T SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections
More informationPM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS
PM734D - Winding 312 Technical Data Sheet PM734D SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and
More informationPM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT
PM734F - Winding 312 Technical Data Sheet PM734F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and
More informationPM734B - Technical Data Sheet. Generator Solutions AS
- Technical Data Sheet STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and certifications can be considered on request. DESCRIPTION
More informationSpec Information. Reactances Per Unit Ohms
GENERATOR DATA Spec Information Generator Specification Frame: 1647 Type: SR5 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 21.0 Connection: SERIES STAR Housing: 00 Phases: 3 No. of Leads: 6
More information440 (12) 416 (12) 416 (12) 440 (12)
ALTERNATOR DATA SHEET Frame Size LVSI804X CHARACTERISTICS No of Bearings 2 WEIGHTS: Stator Assembly: 10141 lb 4 kg Rotor Assembly: 4184 lb 1898 kg Complete Assembly: 18289 lb 8296 kg MAXIMUM SPEED: 2250
More informationGENERATOR DATA JANUARY 30, 2015
GENERATOR DATA JANUARY 30, 2015 For Help Desk Phone Numbers Click here Generator Specification Frame: 1822 Type: SR5 No. of Bearings: 2 Winding Type: FORM WOUND Flywheel: 21.0 Connection: SERIES STAR Housing:
More informationSpec Information. Reactances Per Unit Ohms
GENERATOR DATA Spec Information Generator Specification Frame: LC6134K Type: LC No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 18.0 Connection: - STAR Housing: 0 Phases: 3 No. of Leads: 6 Poles:
More informationPackaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:
Packaged Generators: New Kato Engineering Packaged Generator Line: The new Kato Engineering line of generators is a group of commercial and industrial quality generators that can meet the broadest range
More informationPI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
PI144H - Winding 311 Technical Data Sheet PI144H SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationLow Voltage Alternators
Low Voltage Alternators Excitation and regulation systems SHUNT - PMG - AREP Low Volta SHUNT excitation for basic applications - The AVR power supply voltage is shunted on the alternator output terminals.
More informationLow Voltage Alternators - 4 pole
TAL - A40 - A42 - A44 Electrical and mechanical data Advanced Production Technology Automated winding process to ensure maximum lifespan and reduce human error VPI (vacuum pressure impregnation) insulation
More informationAGN 034 Alternator Reactance
Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 034 Alternator Reactance DEFINITION Reactance Periods Inherent to the design of an alternator are certain internal
More informationGenerator Advanced Concepts
Generator Advanced Concepts Common Topics, The Practical Side Machine Output Voltage Equation Pitch Harmonics Circulating Currents when Paralleling Reactances and Time Constants Three Generator Curves
More information4939 en / a PARTNER ALTERNATORS LSA 54. General features and ratings
99 en - 00 / a PRTNR LTRNTORS LS eneral features and ratings LTRNTOR : LS M / 0kV - 00V - 0z - 00rpm - P (*) Y connection * PR= Peak rating Reactances (%) - class - 0 kv - 00 V unsaturated Short-circuit
More informationAPPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY
APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY 1. The undersigned Interconnection Customer submits this request to interconnect its Large Generating Facility with Transmission
More informationINTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY
INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY Internal Use Only Date Received Time Received Received By: 1. The undersigned Interconnection Customer submits this request to interconnect its Large
More informationR438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE
T1 T7 T2 T8 This manual is to be given to the end user T4 T10 140 mm T5 T11 X2 Z1X1 Z2 E+ E- 0V 110 220 380 200 mm z P1 ST9 AREP PMG This manual concerns the alternator which you have just purchased. We
More informationTechnical Data Sheet for AvK-Alternators
Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 8/1/14 Customer: GENERIC DATASHEET only Project No.: AvK Reference: dsg114l1_6_5_69_a48m988 Object data: Site: Prime Mover: Application: Stationary
More informationTechnical Data Sheet for AvK-Alternators
Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 9/1/13 Customer: GENERIC DATASHEET only Project No.: AvK Reference: dig156l_6_6_138 Object data: Site: Prime Mover: Application: Stationary Power
More informationTechnical Data Sheet for AvK-Alternators
Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 9/1/13 Customer: GENERIC DATASHEET only Project No.: AvK Reference: dig13k_4_5_33 Object data: Site: Prime Mover: Application: Stationary Power Plant
More informationApplication Guidance Notes: Technical Information from Cummins Generator Technologies
Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 007 - Testing POLICY The following is offered as an eplanation of the policy and procedures followed by Cummins
More information4938 en / a PARTNER ALTERNATORS LSA General features and rating4
9 en - 00 / a PRTNR LTRNTORS LS eneral features and rating LTRNTOR : LS M0 / 000kV - 00V - 0z - 00rpm - P (*) Y connection * PR= Peak rating Reactances (%) - class - 000 kv - 00 V unsaturated Short-circuit
More informationR241 A. 400 Hz A.V.R. Installation and maintenance. This manual is to be given to. the end user C B. Air craft p
C1 C B Air craft p This manual is to be given to the end user F 0,1A R3 0,1A A 0 F = 6.3A fast - 250 R1 = 100 Ω - R2 = 10 Ω - 1 R3 = 1 KΩ - 2 x 1 mm 2 F R3 Détail This manual concerns the alternator A.V.R.
More informationR448 & R448 V50 A.V.R.
Armature + 6- This manual is to be given to the end user F1 ST5 Field Slow fuse 250V 10 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 22 ST3 requency 50Hz 60Hz LAM 13
More informationTechnical Data Sheet for AvK-Alternators
Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 3/9/13 Customer: Bitte Interessent eingeben! Project No.: AvK Reference: 1-67-83-1 Object data: Site: Prime Mover: Application: Stationary Power
More informationR 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG
6 5 4 7 8 9 C US 45 en -. / e 5 Hz EXT FREQ 6 Hz SETTING This manual is to be given to the end user VOLT. STAB. I EXC FUSIBLES / FUSES EXT.FREQ. SET. ON ONLY FOR SPECIAL CONFIG. KNEE 5Hz 65Hz 6Hz PHASE
More informationGeneration Interconnection Study Data Sheet Synchronous Machines
FOR INTERNAL USE ONLY GTC Project Number: Queue Date: Generation Interconnection Study Data Sheet Synchronous Machines Customers must provide the following information in its entirety. GTC will not proceed
More informationAGN 005 Fault Currents and Short Circuit Decrement Curves
Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 005 Fault Currents and Short Circuit Decrement Curves DESCRIPTION To facilitate the correct design of an electrical
More informationATV12H018F1 variable speed drive ATV kW hp V - 1ph
Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component
More informationATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application
More informationHCM634G - Technical Data Sheet
HCM634 - Technical Da Sheet HCM634 SPECIFICATIONS & OPTIONS TERMINALS & TERMINAL BOX Marine gs may be ctified to Lloyds, DnV, Bureau Vitas, ABS, manisch-lloyd RINA. Oth standards and ctificio can be coided
More informationATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol
Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable
More informationRE7MY13MW time delay relay 8 functions s V AC DC - 2OC
Characteristics time delay relay 8 functions - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range
More informationD I G I T A L V O L T A G E R E G U L A T O R
The Cat Digital Voltage Regulator is a microprocessor based control designed to provide precise voltage control, robust transient response, and generator protection with industry leading features and versatility.
More informationK Factor Power Transformers
Ashley-Edison AsiaElectricTransformers (UK) K Factor Power Transformers DTKF series Low Voltage Dry Type K Factor Power Transformers AET-DTKF-2004-01: Page 1 Asia Electric Transformers, Entrepreneur Business
More informationState of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company
Engineering data submittal Page 1 WHO SHOULD FILE THIS SUBMITTAL : Anyone in the final stages of in terconnecting a Generation System with Otter Tail Power. This submittal shall be completed and provided
More informationR448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A
Armature + 6- Field Thismanualistobegivento theenduser F1 ST5 Slow fuse 250V 10 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 22 ST3 requency 50Hz 60Hz ST10 R 448 This
More informationABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL
Main Features - Compact and heavy-duty industrial model - Interface: Bit-parallel, push pull Œ Short circuit proof - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096
More informationATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Product availability : Stock - Normally stocked in distribution facility Price* : 191.76 USD Main Range of
More informationr 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES
8 7 9 6 5 4 C 45 en -. / a R 45 DETECT. PH PH. SENSING 5 Hz EXT FREQ 6 Hz SETTING This manual is to be given to the end user VOLT. STAB. I EXC FUSIBLES / FUSES EXT.FREQ. SET. ON ONLY FOR SPECIAL CONFIG.
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationGeneral Description & Features Selection Charts Definition of Terms... 42
SECTION NON-LINEAR LOAD ISOLATION TRANSFORMERS Special winding techniques minimize eddy current losses. A double sized neutral handles excessive neutral currents. UL Listed for K Factor Loads 4, 1 & 20.
More informationRotek AS440 compatible VOLTAGE REGULATOR (AVR)
Rotek AS440 compatible VOLTAGE REGULATOR (AVR) SPECIFICATION INSTALLATION AND ADJUSTMENTS General description Technical specification AS440 is a half wave phase controlled thyristor type AVR and forms
More informationIncremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution
Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm
More informationUNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49
TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact
More informationTechnical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V
Technical Data Sheet Uninterruptible Power Supply On-line VH Series UPS 2000-3000 UL / 208V GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850
More informationATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW
Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector
Characteristics integrated drive ILA with servo motor - 24..48 V - EtherCAT - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network
More informationCode No: R Set No. 1
Code No: R05310204 Set No. 1 III B.Tech I Semester Regular Examinations, November 2007 ELECTRICAL MACHINES-III (Electrical & Electronic Engineering) Time: 3 hours Max Marks: 80 Answer any FIVE Questions
More informationATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW
Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationRotary Measurement Technology Absolute Encoders, Multiturn
Mechanical drive Safety-LockTM High rotational speed -40 to 90 C IP Temperature High IP High shaft load capacity Shock/ vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection
More informationENGINEERING DATA SUBMITTAL For the Interconnection of Generation System
WHO SHOULD FILE THIS SUBMITTAL: Anyone in the final stages of interconnecting a Generation System with Nodak Electric Cooperative, Inc. This submittal shall be completed and provided to Nodak Electric
More informationATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW
Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationLoad Isolation Transformers
4 Non-Linear Load Isolation Transformers Section Special winding techniques minimize eddy current losses. A double sized neutral handles excessive neutral currents. UL Listed for K Factor Loads 4, 13 &
More informationRotary Measurement Technology Incremental Encoders
-20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection
More informationAS440 AUTOMATIC VOLTAGE REGULATOR (AVR)
AS440 AUTOMATIC VOLTAGE REGULATOR (AVR) SPECIFICATION INSTALLATION AND ADJUSTMENTS General description Technical specification AS440 is a half wave phase controlled thyristor type AVR and forms part of
More informationElectronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions and 10 time ranges.
More informationELECTRIC ACTUATOR. Quarter turn(rotary type) - ZGQ Series
ELECTRIC ACTUATOR Quarter turn(rotary type) - ZGQ Series Construction (Inside) - Manual handle - Limit switch cam - Limit switch - Stopper - Cable entries - Valve bracket - Indicator - Motor (Reversible
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationSTAR ELECTRIC COMPANY
STAR ELECTRIC COMPANY STECO manufacturers a complete range of Energy Efficient Mors conforming IS: 325. Efficiency class Improved efficiency PRODUCT RANGE International Standards 60034-1,5 60072 Rotating
More informationRE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC
Characteristics adjustable symmetrical flashing relay - 0.05..1 s - 24 V AC DC - 2OC Price* : 202.00 USD Discontinued Main Range of product Product or component type Contacts type and composition Component
More informationRoHS. High shaft load capacity. Shock / vibration resistant
Due to their sturdy bearing construction in Safety Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up
More informationATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW
Characteristics soft starter for asynchronous motor - ATS48-65 A - 208..690 V - 15..55 KW Main Range of product Altistart 48 Product or component type Product destination Product specific application Device
More informationImpact Assessment Generator Form
Impact Assessment Generator Form This connection impact assessment form provides information for the Connection Assessment and Connection Cost Estimate. Date: (dd/mm/yyyy) Consultant/Developer Name: Project
More informationAF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF
ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC
More informationPART 1 OWNER/APPLICANT INFORMATION
CALHOUN COUNTY ELECTRIC COOP. ASSN. Application for Operation of Customer-Owned Generation This application should be completed as soon as possible and returned to the Cooperative in order to begin processing
More information1 INTRODUCTION ORDER CODE / INFORMATION
INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O
More informationKNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers
KNOW MORE ABOUT THE TRANSFORMERS Glossary Transformers Ambient temperature The existing temperature of the atmosphere surrounding a transformer installation. Ampere The practical unit of electric current.
More information