ROOF-CEILING CONSTRUCTION

Similar documents
ROOF-CEILING CONSTRUCTION

ROOF-CEILING CONSTRUCTION

ROOF-CEILING CONSTRUCTION

ROOF-CEILING CONSTRUCTION

3.1 General Provisions

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

A. Rough carpentry includes but is not limited to the following:

Exterior Wall Fastener Schedule

SECTION ROUGH CARPENTRY 1.1 DESCRIPTION OF WORK:

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

SECTION ROUGH CARPENTRY

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

Wood Connections. Concepts of Well Designed Connections

ICC-ES Evaluation Report

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

DIVISION 6 WOOD AND PLASTICS

Sections & Details VOCABULARY

MAT105: Floor Framing

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

Wood Roof Framing Common Design and Construction Defects Concurrent Session #5.3, Friday April 28, 2017, 9:45 AM-10:30 AM

SECTION ROUGH CARPENTRY

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

PROJECT INSTRUCTIONS Roofing

Joint Evaluation Report

VERSA-LAM. An Introduction to VERSA-LAM Products

Garage Design Guide. October 2018


VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California / 16

SECTION ROUGH CARPENTRY

Nailed Structural-Use Panel and Lumber Beams

APA Performance Rated Rim Boards

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER SECTION: LAMINATED STRAND LUMBER REPORT HOLDER:

Featuring TJ Rim Board and TimberStrand LSL

IRC 2015 Code Compliant Wood Framed Residential Details. Incorrect Installations of Connectors with code references and remedies, discussion.

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

Section Downloads. Terminology Outline. Industry Standards/ Publications. American Softwood Lumber Standard ANSI/TPI 1. Section 02: Terminology

ROOFING City of Grand Rapids Building Safety Division

602.4, TABLE 602.4, , , , , , , , , TABLE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

FASTENERS BUILDING DEPARTMENT

Load Tables, Technical Data and Installation Instructions

City of Virginia Beach, Virginia Typical Deck Details

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

REPORT HOLDER: JAACO CORPORATION NORTHEAST 68 TH STREET, SUITE C-130 REDMOND, WASHINGTON EVALUATION SUBJECT:

IRC 2012 Code Compliant Wood Framed Residential details. Miss Installed Connectors with code references and remedies, discussion.

CUTTING, NOTCHING, AND BORING OF WOOD FRAMING MEMBERS (Unless an alternate design is provided by a licensed Engineer or Architect)

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Typical Deck Details Based on the City of Nixa Residential Deck Ordinance

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Building for High Wind Resistance in Light-Frame Wood Construction

(800) (562) A Subsidiary of the International Code Council

Sections & Details. WOOD SILL and FLOOR CONSTRUCTION NOTES

B. Related Sections: The following Sections contain requirements that relate to this Section:

THE ENGINEERED WOOD ASSOCIATION

SECTION: 15 ZONING RULE LOT AREA 6134 S.F S.F. BUILDING AREA (FOOTPRINT) LOT COVERAGE 20.2% 24.86' FRONT YARD SIDE YARD 8.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Revised September 2003

*Revised September 1, 2003

REINFORCEMENT DESIGN FOR METAL BUILDING SYSTEMS

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

A. Product Data: For each type of process and factory-fabricated product indicated.

Pulaski County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

Glulam Connection Details

PART II ENGINEERED BASIS OF RIDGE AND EAVE VENT DETAILS

Structural Criteria for Residential Flush-Mounted Solar Arrays

Structural Criteria for Residential Rooftop Solar Energy Installations

2. Wood grounds, nailers, blocking, miscellaneous framing, sleepers, etc.

B. Related Requirements: 1. Section "Interior Painting" for priming and backpriming of interior finish carpentry.

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 9 Ventilation Overview Revised

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016

DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

LP SolidStart Laminated Strand Lumber (LSL) and Laminated Veneer Lumber (LVL) Louisiana-Pacific Corporation Revised July 21, 2017

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

Maryland Building Officials Association Typical Deck Details

Structural Criteria for Residential Rooftop Solar Energy Installations

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

WOODEN BUILDINGS 6.1 INTRODUCTION 6.2 TYPICAL DAMAGE AND FAILURE OF WOODEN BUILDINGS. Chapter 6

City of Long Beach Department of Development Services Building and Safety Bureau. Wood Frame Prescriptive Provisions For Residential Construction

A Shell construction

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

GLOSSARY OF TERMS SECTION 8

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

APPLICATION FOR A BUILDING PERMIT

FREDERICK COUNTY USBC/IRC 2015

Turada Hardwood Shingles and Shakes Installation instructions

Pryda Timber Connectors

Connectors for Cold-Formed Steel Curtain-Wall Construction

Product Information & Installation Instructions

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2011

Transcription:

CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL R801.1 Application. The provisions of this chapter shall control the design and construction of the roof-ceiling system for all buildings. R801.2 Requirements. Roof and ceiling construction shall be capable of accommodating all loads imposed according to Section R01 and of transmitting the resulting loads to the supporting structural elements. R801. Roof drainage. In areas where expansive or collapsible soils are known to exist, all dwellings shall have a controlled method of water disposal from roofs that will collect and discharge all roof drainage to the ground surface at least feet ( mm) from foundation walls or to an approved drainage system. SECTION R802 WOOD ROOF FRAMING R802.1 Identification. Load-bearing dimension lumber for rafters, trusses and ceiling joists shall be identified by a grade mark of a lumber grading or inspection agency that has been approved by an accreditation body that complies with DOC PS 20. In lieu of a grade mark, a certificate of inspection issued by a lumber grading or inspection agency meeting the requirements of this section shall be accepted. R802.1.1 Blocking. Blocking shall be a minimum of utility grade lumber. R802.1.2 End-jointed lumber. Approved end-jointed lumber identified by a grade mark conforming to Section R802.1 may be used interchangeably with solid-sawn members of the same species and grade. R802.1. Fire-retardant-treated wood. Fire-retardanttreated wood is any wood product which, when impregnated with chemicals by a pressure process or other means during manufacture, shall have, when tested in accordance with ASTM E8, a listed flame spread index of 2 or less and show no evidence of significant progressive combustion when the test is continued for an additional 20-minute period. In addition, the flame front shall not progress more than 10. feet (200 mm) beyond the center line of the burners at any time during the test. R802.1..1 Labeling. Fire-retardant-treated lumber and wood structural panels shall be labeled. The label shall contain: 1. The identification mark of an approved agency in accordance with Section 10. of the North Carolina Building Code. 2. Identification of the treating manufacturer.. The name of the fire-retardant treatment.. The species of wood treated.. Flame spread and smoke developed rating. 6. Method drying after treatment.. Conformance with appropriate standards in accordance with Sections R802.1..2 through R802.1... 8. For FRTW exposed to weather, damp or wet location, the words No increase in the listed classification when subjected to the Standard Rain Test (ASTM D2898). R802.1..2 Strength adjustments. Design values for untreated lumber and wood structural panels as specified in Section R802.1, shall be adjusted for fire retardanttreated wood. Adjustments to design values shall be based upon an approved method of investigation which takes into consideration the effects of the anticipated temperature and humidity to which the fire-retardant-treated wood will be subjected, the type of treatment and redrying procedures. R802.1..2.1 Wood structural panels. The effect of treatment and the method of redrying after treatment, and exposure to high temperatures and high humidities on the flexure properties of fire-retardant-treated softwood plywood shall be determined in accordance with ASTM D. The test data developed by ASTM D shall be used to develop adjustment factors, maximum loads and spans, or both for untreated plywood design values in accordance with ASTM D 60. Each manufacturer shall publish the allowable maximum loads and spans for service as floor and roof sheathing for their treatment. R802.1..2.2 Lumber. For each species of wood treated the effect of the treatment and the method ofredrying after treatment and exposure to high temperatures and high humidities on the allowable design properties of fire-retardant-treated lumber shall be determined in accordance with ASTM D 66. The test data developed by ASTM D 66 shall be used to develop modification factors for use at or near room temperature and at elevated temperatures and humidity in accordance with an approved method of investigation. Each manufacturer shall publish the modification factors for service at temperatures of not less than 80 F (26. C) and for roof framing. The roof framing modification factors shall take into consideration the climatological location. R802.1.. Exposure to weather. Where fire-retardant-treated wood is exposed to weather, or damp or wet locations, it shall be identified as Exterior to indicate there is no increase in the listed flamespread index as defined in Section R802.1. when subjected to ASTM D 2898. 2006 NORTH CAROLINA RESIDENTIAL CODE 20

R802.1.. Interior applications. Interior fireretardant-treated wood shall have a moisture content of not over 28 percent when tested in accordance with ASTM D 201 procedures at 92 percent relative humidity. Interior fire-retardant-treated wood shall be tested in accordance with Section R802.1..2.1 or R802.1..2.2. Interior fire-retardant-treated wood designated as Type A shall be tested in accordance with the provisions of this section. R802.1.. Moisture content. Fire-retardant-treated wood shall be dried to a moisture content of 19 percent or less for lumber and 1 percent or less for wood structural panels before use. For wood kiln dried after treatment (KDAT) the kiln temperatures shall not exceed those used in kiln drying the lumber and plywood submitted for the tests described in Section R802.1..2.1 for plywood and R802.1..2.2 for lumber. R802.1. Structural glued laminated timbers. Glued laminated timbers shall be manufactured and identified as required in AITC A190.1 and ASTM D. R802.2 Design and construction. Roof-ceilings shall be designed and constructed in accordance with the provisions of this chapter and Figures R606.10(1), R606.10(2) and R606.10() or in accordance with AFPA/NDS. Components of roof-ceilings shall be fastened in accordance with Table R602.(1). R802. Framing details. Rafters shall be framed to ridge board or to each other with a gusset plate as a tie. Ridge board shall be at least 1-inch (2. mm) nominal thickness and not less in depth than the cut end of the rafter. At all valleys and hips there shall be a valley or hip rafter not less than 2-inch (1 mm) nominal thickness and not less in depth than the cut end of the rafter. Hip and valley rafters shall be supported at the ridge by a brace to a bearing partition or be designed to carry and distribute the specific load at that point. Where the roof pitch is less than three units vertical in units horizontal (2-percent slope), structural members that support rafters and ceiling joists, such as ridge beams, hips and valleys, shall be designed as beams. R802..1 Ceiling joist and rafter connections. Ceiling joists and rafters shall be nailed to each other in accordance with Tables R602.(1) and R802..1(9), and the assembly shall be nailed to the top wall plate in accordance with Table R602.(1). Ceiling joists shall be continuous or securely joined where they meet over interior partitions and nailed to adjacent rafters to provide a continuous tie across the building when such joists are parallel to the rafters. Where ceiling joists are not parallel to rafters, subflooring or metal straps attached to the ends of the rafters shall be installed in a manner to provide a continuous tie across the building, or rafters shall be tied to 1-inch by -inch (2. mm by 102 mm) (nominal) minimum-size crossties. The connections shall be in accordance with Table R602.(1) or connections of equivalent capacities shall be provided. Where ceiling joists or rafter ties are not provided at the top plate, the ridge formed by these rafters shall also be supported by a girder designed in accordance with accepted engineering practice. Rafter ties shall be spaced not more than feet (19 mm) on center. A 1-inch by 6-inch (2 mm mm) or 2-inch by -inch (1 mm 102 mm) collar beam shall be nailed in the upper third of the roof to every third pair of rafters not to exceed feet on center. Collar beams shall be connected to the rafters as specified in Table R602.(1) for rafter ties. R802..2 Ceiling joists lapped. Ends of ceiling joists shall be lapped a minimum of inches (6 mm) or butted over bearing partitions or beams and toenailed to the bearing member. When ceiling joists are used to provide resistance to rafter thrust, lapped joists shall be nailed together in accordance with Table R602.(1) and butted joists shall be tied together in a manner to resist such thrust. R802. Allowable ceiling joist spans. Spans for ceiling joists shall be in accordance with Tables R802.(1) and R802.(2). For other grades and species and for other loading conditions, refer to the AF&PA Span Tables for Joists and Rafters. R802. Allowable rafter spans. Spans for rafters shall be in accordance with Tables R802..1(1) through R802..1(8). For other grades and species and for other loading conditions, refer to the AF&PA Span Tables for Joists and Rafters. The span of each rafter shall be measured along the horizontal projection of the rafter. R802..1 Purlins. Purlins are permitted to be installed to reduce the span of rafters as shown in Figure R802..1. Purlins shall be sized no less than the required size of the rafters that they support. Purlins shall be continuous and shall be supported by 2-inch by -inch (1 mm by 102 mm) braces installed to bearing walls at a slope not less than degrees from the horizontal. The braces shall be spaced not more than feet (19 mm) on center and the unbraced length of braces shall not exceed 8 feet (28 mm). R802.6 Bearing. The ends of each rafter or ceiling joist shall have not less than 1 1 / 2 inches (8 mm) of bearing on wood or metal and not less than inches (6 mm) on masonry or concrete. R802.6.1 Finished ceiling material. If the finished ceiling material is installed on the ceiling prior to the attachment of the ceiling to the walls, such as in construction at a factory, a compression strip of the same thickness as the finish ceiling material shall be installed directly above the top plate of bearing walls if the compressive strength of the finish ceiling material is less than the loads it will be required to withstand. The compression strip shall cover the entire length of such top plate and shall be at least one-half the width of the top plate. It shall be of material capable of transmitting the loads transferred through it. R802. Cutting and notching. Structural roof members shall not be cut, bored or notched in excess of the limitations specified in this section. R802..1 Sawn lumber. Notches in solid lumber joists, rafters and beams shall not exceed one-sixth of the depth of the member, shall not be longer than one-third of the depth of the member and shall not be located in the middle one-third of the span. Notches at the ends of the member shall not exceed one-fourth the depth of the member. The tension side 20 2006 NORTH CAROLINA RESIDENTIAL CODE

of members inches (102 mm) or greater in nominal thickness shall not be notched except at the ends of the members. The diameter of the holes bored or cut into members shall not exceed one-third the depth of the member. Holes shall not be closer than 2 inches (1 mm) to the top or bottom of the member, or to any other hole located in the member. Where the member is also notched, the hole shall not be closer than 2 inches (1 mm) to the notch. Exception: Notches on cantilevered portions of rafters are permitted provided the dimension of the remaining portion of the rafter is not less than -inch nominal (102 mm) and the length of the cantilever does not exceed 2 inches (610 mm). R802..2 Engineered wood products. Cuts, notches and holes bored in laminated veneer lumber, glue-laminated members or I-joists are not permitted unless the effect of such penetrations are specifically considered in the design of the member. R802.8 Lateral support. Rafters and ceiling joists having a depth-to-thickness ratio exceeding to 1 based on nominal dimensions shall be provided with lateral support at points of bearing to prevent rotation. R802.8.1 Bridging. Rafters and ceiling joists having a depth-to-thickness ratio exceeding 6 to 1 based on nominal dimensions shall be supported laterally by solid blocking, diagonal bridging (wood or metal) or a continuous 1-inch by -inch (2. mm by 6 mm) wood strip nailed across the rafters or ceiling joists at intervals not exceeding 8 feet (28 mm). R802.9 Framing of openings. Openings in roof and ceiling framing shall be framed with header and trimmer joists. When the header joist span does not exceed feet (19 mm), the header joist may be a single member the same size as the ceiling joist or rafter. Single trimmer joists may be used to carry a single header joist that is located within feet (91 mm) of the trimmer joist bearing. When the header joist span exceeds feet (19 mm), the trimmer joists and the header joist shall be doubled and of sufficient cross section to support the ceiling joists or rafter framing into the header. Approved hangers shall be used for the header joist to trimmer joist connections when the header joist span exceeds 6 feet (1829 mm). Tail joists over feet (68 mm) long shall be supported at the header by framing anchors or on ledger strips not less than 2 inches by 2 inches (1 mm by 1 mm). R802.10 Wood trusses. R802.10.1 Truss design drawings. Truss design drawings, prepared in conformance with Section R802.10.1, shall be provided to the building official and approved prior to installation. Truss design drawings shall include, at a minimum, the information specified below. Truss design drawing shall be provided with the shipment of trusses delivered to the jobsite. 1. Slope or depth, span and spacing. 2. Location of all joints.. Required bearing widths.. Design loads as applicable..1. Top chord live load (including snow loads)..2. Top chord dead load... Bottom chord live load... Bottom chord dead load... Concentrated loads and their points of application..6. Controlling wind and earthquake loads.. Adjustments to lumber and joint connector design values for conditions of use. 6. Each reaction force and direction.. Joint connector type and description (e.g., size, thickness or gauge) and the dimensioned location of each joint connector except where symmetrically located relative to the joint interface. 8. Lumber size, species and grade for each member. 9. Connection requirements for: 9.1. Truss to truss girder. 9.2. Truss ply to ply. 9.. Field splices. 10. Calculated deflection ratio and/or maximum description for live and total load. 11. Maximum axial compression forces in the truss members to enable the building designer to design the size, connections and anchorage of the permanent continuous lateral bracing. Forces shall be shown on the truss design drawing or on supplemental documents.. Required permanent truss member bracinglocation. R802.10.2 Design. Wood trusses shall be designed in accordance with accepted engineering practice. The design and manufacture of metal plate connected wood trusses shall comply with ANSI/TPI 1. The truss design drawings shall be prepared by a registered professional where required by the statutes of the jurisdiction in which the project is to be constructed in accordance with Section R106.1. R802.10. Bracing. Trusses shall be braced to prevent rotation and provide lateral stability in accordance with the requirements specified in the construction documents for the building and on the individual truss design drawings. In the absence of specific bracing requirements, trusses shall be braced in accordance with TPI/HIB. R802.10. Alterations to trusses. Truss members shall not be cut, notched, drilled, spliced or otherwise altered in any way without the approval of a registered design professional. Alterations resulting in the addition of load (e.g., HVAC equipment, water heater) that exceeds the design load for the 2006 NORTH CAROLINA RESIDENTIAL CODE 20

TABLE R802.(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 20) CEILING JOIST ( 19.2 #2 # #1 #2 # # # #2 # #1 #2 # # # #2 # #1 #2 # Southern -pine # # DEAD LOAD = psf 2 2 6 2 8 2 10 Maximum ceiling joist spans -8 11- -11-8 11-6 11-6 11-6 10-10- 10-1 10-10- (continued) 20-8 11 0 1 0 20-11 1-0 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1-0 1 1 1 1 1-0 1 1-6 1 1 1 2-8 20-1 2-8 2-2 2-0 20-1 2-8 21-8 2-2 2-2- 20-1 2-8 2-10 2-0 2-22-10 21-9 2-2-1 2-1 22-10 22-22- 2-22- 0 21-11 21-6 20-6 0 22-10 22-21-11 21-6 0 2-6 2-6 2 2-6 21-21- 22-2 21-2-8 1 2-1 20-2-8 2-8 1 206 2006 NORTH CAROLINA RESIDENTIAL CODE

CEILING JOIST ( 2 TABLE R802.(1) continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 20) #2 # #1 #2 # # # DEAD LOAD = psf 2 2 6 2 8 2 10 Maximum ceiling joist spans 10-8-2 Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. Span exceeds 26 feet in length. 1 1-6 1-6 21-20-1 1 20-1 1 21-2 20-10 20-1 11 1 1 2-6 22-11 1 2-11 22-1 2-11 1 2 22-11 22-11 1 2006 NORTH CAROLINA RESIDENTIAL CODE 20

TABLE R802.(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 20) CEILING JOIST ( 19.2 #2 # #1 #2 # # # #2 # #1 #2 # # # #2 # #1 #2 # # # DEAD LOAD = 10 psf 2 2 6 2 8 2 10 Maximum ceiling joist spans 10-8-2 1 1 1 0 (continued) 1 1-6 1-6 1 1- -8 1-1-6 1-0 0 1- - 11-0 1-6 - -11 0 21-20-1 1 20-1 1 21-2 20-10 20-1 11 1 1 1-1 1 19-11 1-1 - - 1 0 1-6 1-8 1 1-9 0-1 1 2-6 22-11 1 2-11 22-1 2-11 1 2 22-11 22-11 1 2 21-1 1 2-8 20-8 1 1 2-2-1 20-9 1-8 2-1 1 1 1 2-1 1-8 22-11 10 1-8 2-1 21-1 11 21-8 1-8 208 2006 NORTH CAROLINA RESIDENTIAL CODE

CEILING JOIST ( 2 TABLE R802.(2) continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 20) #2 # #1 #2 # # # DEAD LOAD = 10 psf 2 2 6 2 8 2 10 Maximum Ceiling Joist Spans -2 0-6 -9-2 -2 Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. Span exceeds 26 feet in length. 1-0 1-1 10-1 1 1 1-1-10 1-1 0 0 1-1- 1 - - 20-6 1 1-21-6 10 1 1 - - - 2006 NORTH CAROLINA RESIDENTIAL CODE 209

TABLE R802..1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180) RAFTER ( 19.2 #2 # #1 #2 # # # #2 # #1 #2 # # # #2 # #1 #2 # # # DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a 11-6 1-1 1-10 10-11-1 10-10- 10-10- 1 1 9-9- - 0 0 1 1 1 1-0 1 1 1 1 1-0 1-6 1 - - 1 1-6 1 1 1-0 1-1 1 1-1-8-11 1 1-1-1 1-1 1 2-9 22-0 22-21-10 20-8 0 2-22-11 22-21-11 0 21-1 20-11 11 21-2 20-10 1 11 20-1-9 1-1 1 1-11 1 1-9 1-1 1 1 - (continued) 2-8 1 2-1 20-2-8 2-8 1 2-9 22-1 2-2 21-11 1 2 2-2 2 22-22- 1 2-11 21-8 20-2-6 21-1 20-0 2 2-21-2 1 2-11 20-20- 22-6 22-6 2-1 22-6 2-9 2 2-9 2-9 2-2 2-6 1-9 2-6 2-2 1-9 2-10 1 2-6 2-6 1-9 11-6 10-11-1 1 10-0 10- -9 9-9- 6- -9-9 1 1-0 1 1 1-1 1 1-1-6-11 - 1 1-0 1-11- 1-8 9-1- 11-11- 2-1 22-11 11 2-21-9 1 21-9 20-11 1 1-6 21-2 10 10 1 1 11 2-9 22-1 2-2 21-11 1 2 2-2 22-22- 1 2-9 20-19- 1-6 2-20-0 11 1-6 22-20-1 2-0 19-19- 1-6 22-1 1 1-22- 1 1 1-2 20-1 1-10 1 1 1-2-9 2 2-9 2-9 2-10 22-2- 22-0 2-1 22-22- 21-9 20-1 2-9 21-20-1 1 2-21-6 2-20- 20-1 210 2006 NORTH CAROLINA RESIDENTIAL CODE

RAFTER ( 2 #2 # #1 #2 # # # TABLE R802..1(1) continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180) DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a 1 1 0 1-6 - 11-0 - 1-0 10 0 10 1-6 1-8 1 1-9 0-1 2-1 1-8 22-9 11 10 1-8 2-8 21-1 11 21-8 1-8 22-6 1 21-11 20-9 1 2-2 22-2 1 2-2 1 1 - - - 1-1-1 10- - 1-1- -8 1 20-1 1-8 1 1 1-6 22-11 1 1 1 1-8 1-8 2-1 2-0 1 11 21-9 19-21-9 1 1 Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the factors given below: H C /H R Rafter Span Adjustment Factor 2/ or greater 0.0 1/2 0.8 1/ 0.6 1/ 0.6 1/ 0.8 1/6 0.90 1/. and less 1.00 where: H C = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls. H R = Height of roof ridge measured vertically above the top of the rafter support walls. b. Span exceeds 26 feet in length. 2006 NORTH CAROLINA RESIDENTIAL CODE 211

TABLE R802..1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 20) RAFTER ( 19.2 #2 # #1 #2 # # # #2 # #1 #2 # # # #2 # #1 #2 # # # DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a 10-1 1 1 1 1 0-1 1-6 1-6 1-6 1-6 1 1-1 1-1- 1-1-0 1-6 1-1 1 1- -11 1 1-6 1- -11-8 -8 1 21-20-10 20-0 20-11 1 0 21-2 20-10 20-11 0 1 11 1 1 1-19- 11 1 1 1-9 1-9 1 1-9 1-1 - - 1 1-9 1-1 1 1 - (continued) 2-8 1 2 2-1 20-2 2-10 2-10 1 2 2-9 22-1 2-8 2-1 21-11 1 2-2-1 2-2 2-1 22-22- 1 2-21-8 20-22- 21-1 20-0 2-1 22-8 21-2 1 21-9 20-20- 22-6 22-6 2-1 22-6 2-9 2 2-9 2-9 2-2 2-6 1-9 2-6 2-2 1-9 2-10 1 2-6 2-6 1-9 10-1 1 1 1-9 6- -9-9 1 1-6 1 1 1- -11-1- 1-0 1-0 11-1- 1-6 9- -11 11-11- 21-1 20-11 11 21-2 20-10 1 11 1 1 1 1-6 19-10 1 1 1 1 1 2-9 22-1 2-2 21-11 1 2 2-2 2 22-22- 1 2-9 20-19- 1-6 2-8 20-0 11 1-6 2-22- 20-1 2-0 19-19- 1-6 22-1 1 1-22- 1 1 1-2-1 20-1 1-10 1 1 1-2-9 2 2-9 2-9 2-10 22-2- 22-0 2-1 22-22- 21-9 20-1 2-9 21-20-1 1 2-21-6 2-20- 20-1 2 2006 NORTH CAROLINA RESIDENTIAL CODE

RAFTER ( 2 #2 # #1 #2 # # # TABLE R802..1(2) continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 20) DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a 0 0-0 -6-6 1-0 0-0 - 0 0 1-6 1-8 0-1 0 21-10 1 1-8 20-8 11 10 1-8 21-6 21-1 11 20-2 1-8 22-6 1 2-1 21-11 20-9 1 2-2 22-2 1 2-1 - 0 - - - 1-0 - 10- - 1 1- -8 20-1 1-8 1 1 1-6 21-6 1 1 1 1-8 1-8 2-1 2-0 1 11 21-9 19-21-9 1 1 Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the factors given below: H C/ H R Rafter Span Adjustment Factor 2/ or greater 0.0 1/2 0.8 1/ 0.6 1/ 0.6 1/ 0.8 1/6 0.90 1/. and less 1.00 where: H C = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls. H R = Height of roof ridge measured vertically above the top of the rafter support walls. b. Span exceeds 26 feet in length. 2006 NORTH CAROLINA RESIDENTIAL CODE 21

TABLE R802..1() RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=0 psf, ceiling not attached to rafters, L/Δ = 180) RAFTER ( 19.2 #2 # #1 #2 # # # #2 # #1 #2 # # # #2 # #1 #2 # # # DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a 9-0 9-8-2 1 8-2 8-2 1-9 1 1 1-1-6 1-1-6 1-1-6 1 11-1- 1-0 0 1 1 20-9 1 20-20-0 1-1 10 10 1 1 1 1-9 1 1-1 (continued) 22-9 21-2 22-2 2-9 22-2-6 21-21- 2-9 1 1 1-11 22-9 19-1-11 2-8 21-19- 1-22-1 1 1 1-11 21-8 1 21-1 1 22-1 1 1-20-2 2-8 2-9 2-20-0 2-8 2-8 22-10 21-22- 21-1 2 22-1 2 21-21- 2-2 2-8 20-19- 2-20- 0 2-9- 0 - -6-2 -6 1 0 - - -6 1-1 1-6 -11 1-1-6 11-1 1-1 20-1 1 1-20- 1 1-6 10-1 1-10- 1 1-6 1-6 10-0 2-6 20-1 2-1 1 1 22-2 11 22-9 1 1 21-1 20-10 - 2-8 1 1-1-0 1 1 1 1-8 22-0 1 2-22-1 1 2-0 21-9 1 2-11 22-1 22-1 1 2-8 20-1 1-6 2-2 11 10 1-6 22-10 20-2 1-6 22-10 1 1 1-6 22-6 22-1 1-2-9 1 21 2006 NORTH CAROLINA RESIDENTIAL CODE

RAFTER ( 2 #2 # #1 #2 # # # TABLE R802..1() continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=0 psf, ceiling not attached to rafters, L/Δ = 180) DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a 1-6 0 - - 1 11-0 1 1 1-8 20-8 1 22-6 22-1 1-2-1 1-11 -6-6 -6 0-9 -11-11 -6-1-11 11-6 1 1-6 1-0 1-0 1-1 1-8 1-6 1-6 20-1 1 1-1 2-0 -8 Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the factors given below: H C /H R Rafter Span Adjustment Factor 2/ or greater 0.0 1/2 0.8 1/ 0.6 1/ 0.6 1/ 0.8 1/6 0.90 1/. and less 1.00 where: H C = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls. H R = Height of roof ridge measured vertically above the top of the rafter support walls. b. Span exceeds 26 feet in length. 2006 NORTH CAROLINA RESIDENTIAL CODE 21

TABLE R802..1() RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=0 psf, ceiling not attached to rafters, L/Δ = 180) RAFTER ( 19.2 #2 # #1 #2 # # # #2 # #1 #2 # # # #2 # #1 #2 # # # DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a 8-2 0 8-2 0 - -6 - - 6-6 - - -0 6-6 -11-1- 11-1 1-0 - -1 11-1 11-1 9- - 1 1 1-1- 1-0 1-1- 1-0 1 1-8 1-6 11-1 1-8 1-1- (continued) 22-1 21-1 1 21-11 20-20-8 1 1 1-8 11 1 1 1-8 1-1 1 1 2 21-20-2 1-2-6 11 1-2-1 21-1 2-1 20-2 20-22-6 22-1 1-2- 1 20-6 1 1-1 20-2 1-1 22-10 1-11 1 1 1-1 -0 8-2 -9 0-8 - -8-6 -11-8 - - - -6-1- 0 10-0 1-0 1-0 11-1 10-0 6-6- 1 6-1-0 1-0 1-8 1-8 1-8 1-1 10-1 1-8 1 20-9 1-20- 1 0 21-11 1 19-11 1 1-11 1 1-6 11 1-1 1-11 1-11 1 1-1- - 18 1-1- 2-0 20-0 2-1 1 22-1 22-20-10 1- - 20-1 - 2-10 1 1 1-1 1-1 1 1-21-9 1 1 2 2006 NORTH CAROLINA RESIDENTIAL CODE

RAFTER ( 2 #2 # #1 #2 # # # TABLE R802..1() continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=0 psf, ceiling not attached to rafters, L/Δ = 180) DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a -1-8 - -1 - -1 10-1 1 0 10-1 1 1-0 1 1-8 0-1 1-8 1 1-1- 1 1 11-1 1-1- 6-6 -10 - -11-10 -1-10 0-10- 0-9 0 1-8 1-8 1 1-1- Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the factors given below: H C /H R Rafter Span Adjustment Factor 2/ or greater 0.0 1/2 0.8 1/ 0.6 1/ 0.6 1/ 0.8 1/6 0.90 1/. and less 1.00 where: H C = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls. H R = Height of roof ridge measured vertically above the top of the rafter support walls. b. Span exceeds 26 feet in length. 1-0 1 1-0 1 1-11 2006 NORTH CAROLINA RESIDENTIAL CODE 21

TABLE R802..1() RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=0 psf, ceiling attached to rafters, L/Δ = 20) RAFTER ( 19.2 #2 # #1 #2 # # # #2 # #1 #2 # # # #2 # #1 #2 # # # DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a 1 0 0-0 -6-6 -9-6 -2-6 -2-0 -0 1-6 1-6 1- - 1-6 1- -11-11 1-0 - - - 1 11-11- 0 11-1 1 10 10 1 1 10 1-1-0 1-0 1 0 1-1- 0 1-6 1 (continued) 2-1 22-9 21-22-9 22-2 2-8 2-2 22-22- 21-21- 21-10 1 1 1-11 20-8 19-1-11 21-6 21-1 19-1- 20-2 1 1 1-11 20-1 1 1 1 20-2 1 1 1-1 2-8 2-9 2-20-0 2-8 2-8 22-10 21-2-1 22-21-1 2 22-1 2-21- 21-2 2-20- 19-2- 2-20- 0 2-1 1 0 - -6 0-2 -6 0 - - -6-9 -6 - -2 1-6 -11 1-1-0-11-1-11- 1 11-10 1 10-1 1 1-6 10-1- 10-0 1-6 1-6 10-0 1-0 2-1 20-1 22-9 1 1 2-8 22-2 11 22-1 1 21-1 20-8 - 21-6 1 1-1-0 1 1 1 1-8 20-2 1 2-22-1 1 2-0 21-9 1 2-11 22-1 22-1 1 2-8 20-1 1-6 2-2 11 10 1-6 22-10 20-2 1-6 22-10 1 1 1-6 22-6 22-1 1-2- 1 218 2006 NORTH CAROLINA RESIDENTIAL CODE

RAFTER ( 2 #2 # #1 #2 # # # TABLE R802..1() continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=0 psf, ceiling attached to rafters, L/Δ = 20) DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a - -0-0 - 6-6 6-6 11-1 1 1 1-8 1-10 1 1 1-8 1 1 22-6 21-11 1-22-10 1 - -11-6 -6-0 -9-11 -11-6 1-11 11-6 1-8 1 1-6 1-0 1-0 1-1 1-8 1-6 1-6 (feet (feet (feet (feet (feet (feet (feet (feet (feet (feet Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the factors given below: H C /H R Rafter Span Adjustment Factor 2/ or greater 0.0 1/2 0.8 1/ 0.6 1/ 0.6 1/ 0.8 1/6 0.90 1/. and less 1.00 where: H C = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls. H R = Height of roof ridge measured vertically above the top of the rafter support walls. b. Span exceeds 26 feet in length. 20-1 1 1-1 22-10 -8 2006 NORTH CAROLINA RESIDENTIAL CODE 219

TABLE R802..1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=0 psf, ceiling attached to rafters, L/Δ = 20) RAFTER ( 19.2 #2 # #1 #2 # # # #2 # #1 #2 # # # #2 # #1 #2 # # # DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a - - -6 - -0 - - -9 - -11-11 -11 - -1 11-11- 1 1 10-10- 1 10-1 9-1 - 1 1 1 1-1- 1 1-8 1-0 1 1-8 1-1- 1-8 1-11 1-1- 11-1 1-1-1 - (continued) 20-1 1 1 11 1 1 1 1-8 1 1-0 1 1-8 1 1-1-0 1 1 2-8 21-20-2 1-2- 11 1-2- 2-9 21-1 22-10 20-2 20-2 1-22- 21-2 1-22-0 1 20-9 20-6 1 1-1 11 1-1 20-9 1-11 1 1 1-1 - -6 - -9-0 -8-8 -11-8 - - -6 - -1 0 10-0 11-1 0 10-1 10-10- 0 6-6- 1 6-1 1 1-0 1-8 1-8 1-8 1-1- 1 10-1 1-1 20-1- 1 1 0 11 1 1 11 1 1-11 1-6 1 1-1 1-11 1-11 1 1-1- - 1-0 1-1- (feet (feet (feet (feet (feet (feet (feet (feet (feet (feet 2-0 20-0 2-1 1 2-22- 1 22-20-10 1- - 20-1 - 22-0 1 1 1-1 1-1 1 1-20-9 1 1 220 2006 NORTH CAROLINA RESIDENTIAL CODE

RAFTER ( 2 #2 # #1 #2 # # # TABLE R802..1(6) continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=0 psf, ceiling attached to rafters, L/Δ = 20) DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a -1-9 -8 - -1-9 - -8-1 1 0 9-0 1 1-1 0-1 0 1-8 1 1-1- 1 19-1 11-1 1-1- -10-9 - -11-10 -1-8 -10 0-0 -9 0 1-8 0 1-1- (feet (feet (feet (feet (feet (feet (feet (feet (feet (feet Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the factors given below: H C /H R Rafter Span Adjustment Factor 2/ or greater 0.0 1/2 0.8 1/ 0.6 1/ 0.6 1/ 0.8 1/6 0.90 1/. and less 1.00 where:h C = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls. H R = Height of roof ridge measured vertically above the top of the rafter support walls. 1-0 1 1-0 19-1-11 2006 NORTH CAROLINA RESIDENTIAL CODE 221

TABLE R802..1() RAFTER SPANS FOR 0 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180) RAFTER ( 19.2 #2 # #1 #2 # # # #2 # #1 #2 # # # #2 # #1 #2 # # # DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum Rafter Spans a -2 - - -0-9 - 6-6 -8 - -8-9 -9 - - -0-6 -2-0 6- - - - -0 1 10-0 1 9-6- 1-8 1-6 1-1-0 - (continued) 1 10 1-8 1 1 1-11 1-1 1-10 1-10- 1-1 1-1 1 1-10 1-22-6 22-1 1-2-10 1 1 1 21-8 1 1-1 1-9 1-10 1 1-20- 1-1-10 1-10 6- -9-2 6-6 -9 - -1-0 6-6- -9-1 6-6 -8 - -1 - -1 - -9-2 -11-9 -11 - -0-11 -9 11-1 10-1 0 10-1 1-9 - -6-2 -6-11 - - -6 1 1-8 -1 1-11 1-11 1-0 1 1-0 -6 1 1 1-0 1 1-0 0-1 10 1-8 11-1 1 1-1 0 1- (feet (feet (feet (feet (feet (feet (feet (feet (feet (feet 21-2 1 20-10 - 2-10 1 1-1 1 1-1- 1 1 11-1 1-1- 1 1-11 1-0 1 1-1 10-1-0 1-0 222 2006 NORTH CAROLINA RESIDENTIAL CODE

RAFTER ( 2 #2 # #1 #2 # # # TABLE R802..1() continued RAFTER SPANS FOR 0 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180) DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a (feet -8 - -8-11 -8 - -11-9 -6-8 -8-0 -2-2 -2 9- - -2 1-6 11-1 11-1 1 1-11 1-0 -9-9 - - - - - -11 - -9 - - - - - 6-6 -11-11 9-0 - -9 6-6 6-6 -11 10-6- 6-6- -11 1 1-8 1 1 0 11-6 0 1-11 -11 0 Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the factors given below: H C /H R Rafter Span Adjustment Factor 2/ or greater 0.0 1/2 0.8 1/ 0.6 1/ 0.6 1/ 0.8 1/6 0.90 1/. and less 1.00 where: H C = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls. H R = Height of roof ridge measured vertically above the top of the rafter support walls. 2006 NORTH CAROLINA RESIDENTIAL CODE 22

TABLE R802..1(8) RAFTER SPANS FOR 0 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/Δ = 20) RAFTER ( 19.2 #2 # #1 #2 # # # #2 # #1 #2 # # # #2 # #1 #2 # # # DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a 6-6 6-6 6-6 - 6- -9 - -11-9 -6 - -11-8 -9-8 -8 - - -0-6 -2-0 -9-8 -6 - - - -0 10-1 9-0 9-1 6-1- 1-1-0 1-8 -11-8 11-6 (continued) 1-8 10 1 1-11 1-1 1-1- 10-1- 1-1 1-1 1-8 1-1-10 1-22-1 20-10 1-21-8 1 20-11 1 1 1 1-1 1-9 1-10 1 1-1 1-1-10 1-10 6- -9 6-6 -9 6-6 -1-9 6- -1-11 -8 - -1 - -9-1 - -9-6 -2-11 -9-9 -8 - -0-9 10-1 9-0 1 1 9- -9 - -6-2 -6-11 - - -6 1-1- -1 1-0 1-8 -11 1-8 11-6 -6 1-0 10 1 0-1 1-8 11-1 1-1-1 0 1-21-2 1 20-10 - 21-8 1 1-1 1 1-1- 1 1 1 11-1 1-1- 1 1-11 1-0 1 1-1 10-1-0 1-0 22 2006 NORTH CAROLINA RESIDENTIAL CODE

RAFTER ( 2 #2 # #1 #2 # # # TABLE R802..1(8) continued RAFTER SPANS FOR 0 PSF GROUND SNOW LOAD a (Ceiling attached to rafters, L/Δ = 20) DEAD LOAD = 10 psf DEAD LOAD = 20 psf 2 2 6 2 8 2 10 2 2 2 6 2 8 2 10 2 Maximum rafter spans a -8 - -2-11 -8 - - - -9-8 -8 - -2-2 -2-1 -2 11-1 1-6 11-1 11-1 1 1-11 1-0 -9 - - -2 - - - - - -9 - - - - 6-6 -11-11 0 - -9 6-6 6-6 -11 10-6- 6-11-1 6- -11 1 1 1 0 11-6 0 1-11 -11 0 Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the factors given below: H C /H R Rafter Span Adjustment Factor 2/ or greater 0.0 1/2 0.8 1/ 0.6 1/ 0.6 1/ 0.8 1/6 0.90 1/. and less 1.00 where: H C = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls. H R = Height of roof ridge measured vertically above the top of the rafter support walls. 2006 NORTH CAROLINA RESIDENTIAL CODE 22

RAFTER SLOPE : : : : 9: : RAFTER ( 2 2 2 2 2 2 TABLE R802..1(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONS a,b,c,d,e,f GROUND SNOW LOAD (psf) 0 0 0 Roof span (feet) 20 28 6 20 28 6 20 28 6 Required number of d common nails a,b per heel joint splices c,d,e,f 6 8 11 6 9 8 11 6 8 10 6 11 1 21 8 11 9 1 6 9 6 6 9 6 For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 pound per square foot = 0.09kN/m 2. a. 0d box nails shall be permitted to be substituted for d common nails. b Nailing requirements shall be permitted to be reduced 2 percent if nails are clinched. c. Heel joint connections are not required when the ridge is supported by a load-bearing wall, header or ridge beam. d. When intermediate support of the rafter is provided by vertical struts or purlins to a loadbearing wall, the tabulated heel joint connection requirements shall be permitted to be reduced proportionally to the reduction in span. e. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices. f. When rafter ties are substituted for ceiling joists, the heel joint connection requirement shall be taken as the tabulated heel joint connection requirement for two-thirds of the actual rafter-slope. 8 11 6 8 10 6 1 2 9 1 9 1 10 8 6 1 20 0 11 1 22 9 18 9 1 10 8 6 8 6 9 11 1 21 8 11 9 1 6 9 6 1 20 0 1 2 9 18 9 1 10 8 20 26 9 1 20 29 2 9 11 1 9 1 10 226 2006 NORTH CAROLINA RESIDENTIAL CODE

For SI: 1 inch = 2. mm, 1 foot = 0.8 mm, 1 degree = 0.018 rad. NOTE: Where ceiling joints run perpendicular to the rafters, rafter ties shall be nailed to the rafter near the plate line and spaced not more than feet on center. FIGURE R802..1 BRACED RAFTER CONSTRUCTION TABLE R802.11 REQUIRED STRENGTH OF TRU OR RAFTER CONNECTIONS TO RESIST WIND UPLIFT FORCES OF 20 PSF OR GREATER a,b,c,e,f (Pounds per connection) BASIC WIND SPEED ( second gust) ROOF SPAN (feet) 20 2 28 2 6 0 OVERHANGS d (pounds/feet) 8-2 -0-1 -9-19 -21-21 -8. 90-91 -11-181 -2-22 -22-02 -.22 100-11 -218-262 -0-9 -9-6 -.6 110-1 -292-1 -09-6 -26-8 -6.6 For SI: 1 inch = 2. mm, 1 foot = 0 mm, 1 mph = 1.61 km/hr, 1 pound/foot = 1.99 N/m, 1 pound = 0. kg. a. The uplift connection requirements are based on a 0 foot mean roof height located in Exposure B. For Exposures C and D and for other mean roof heights, multiply the above loads by the Adjustment Coefficients in Table R-01.2(). b. The uplift connection requirements are based on the framing being spaced 2 inches on center. Multiply by 0.6 for framing spaced inches on center and multiply by 0. for framing spaced inches on center. c. The uplift connection requirements include an allowance for 10 pounds of dead load. d. The uplift connection requirements do not account for the effects of overhangs. The magnitude of the above loads shall be increased by adding the overhang loads found in the table. The overhang loads are also based on framing spaced 2 inches on center. The overhang loads given shall be multiplied by the overhang projection and added to the roof uplift value in the table. e. The uplift connection requirements are based upon wind loading on end zones as defined in Section M09.6 of the North Carolina Building Code. Connection loads for connections located a distance of 20% of the least horizontal dimension of the building from the corner of the building are permitted to be reduced by multiplying the table connection value by 0. and multiplying the overhang load by 0.8. f. For wall-to-wall and wall-to-foundationconnections, the capacity of the uplift connector is permitted to be reduced by 100 pounds for each full wall above. (For example, if a 600-pound rated connector is used on the roof framing, a 00-pound rated connector is permitted at the next floor level down.) 2006 NORTH CAROLINA RESIDENTIAL CODE 22

truss shall not be permitted without verification that the truss is capable of supporting such additional loading. R802.10. Truss to wall connection. Trusses shall be connected to wall plates by the use of approved connectors having a resistance to uplift of not less than 1 pounds (9. kg.) and shall be installed in accordance with the manufacturer s specifications. For roof assemblies subject to wind uplift pressures of 20 pounds per square foot (0.98 kn/m 2 ) or greater, as established in Table R01.2(2), adjusted for height and exposure per Table R01.2(), see section R802.11. R802.11 Roof tie-down. R802.11.1 Uplift resistance. Roof assemblies which are subject to wind uplift pressures of 20 pounds per square foot (0.98 kn/m 2 ) or greater shall have roof rafters or trusses attached to their supporting wall assemblies by connections capable of providing the resistance required in Table R802.11. Wind uplift pressures shall be determined using an effective wind area of 100 square feet (9. m 2 ) and Zone 1 in Table R01.2(2), as adjusted for height and exposure per Table R01.2(). If the resulting adjusted wind-uplift pressure is 20 psf (0.96kN/m 2 ) or more, then uplift resistance must be provided in accordance with Table R802.11. A continuous load path shall be provided to transmit the uplift forces from the rafter or truss ties to the foundation. SECTION R80 ROOF SHEATHING R80.1 Lumber sheathing. Allowable spans for lumber used as roof sheathing shall conform to Table R80.1. Spaced lumber sheathing for wood shingle and shake roofing shall conform to the requirements of Sections R90. and R90.8. Spaced lumber sheathing is not allowed in Seismic Design Category D 2. For SI: TABLE R80.1 MINIMUM THICKNE OF LUMBER ROOF SHEATHING RAFTER OR BEAM ( MINIMUM NET THICKNE ( 2 / 8 8 a 1 1 / 2 T & G 60 b 2 c 1 inch = 2. mm. a. Minimum 20 F b, 0,000 E. b. Minimum 20 F b, 660,000 E. c. Minimum 600 F b, 1,10,000 E. R80.2 Wood structural panel sheathing. R80.2.1 Identification and grade. Wood structural panels shall conform to DOC PS 1, DOC PS 2 or, when manufactured in Canada, CSA 0, and shall be identified by grade mark or certificate of inspection issued by an approved agency. Wood structural panels shall comply with the grades specified in Table R0.2.1.1(1). R80.2.1.1 Exposure durability. All wood structural panels, when designed to be permanently exposed in outdoor applications, shall be of an exterior exposure durability. Wood structural panel roof sheathing exposed to the underside may be of interior type bonded with exterior glue, identified as Exposure 1. R80.2.1.2 Fire-retardant-treated plywood. The allowable unit stresses for fire-retardant-treated plywood, including fastener values, shall be developed from an approved method of investigation that considers the effects of anticipated temperature and humidity to which the fire-retardant-treated plywood will be subjected, the type of treatment and redrying process. The fireretardant-treated plywood shall be graded by an approved agency. R80.2.2 Allowable spans. The maximum allowable spans for wood structural panel roof sheathing shall not exceed the values set forth in Table R0.2.1.1(1). R80.2. Installation. Wood structural panel used as roof sheathing shall be installed with joints staggered or nonstaggered in accordance with Table R602.(1), or APA E0 for wood roof framing or with Table R80. for steel roof framing. SECTION R80 STEEL ROOF FRAMING R80.1 General. Elements shall be straight and free of any defects that would significantly affect their structural performance. Cold-formed steel roof framing members shall comply with the requirements of this section. R80.1.1 Applicability limits. The provisions of this section shall control the construction of steel roof framing for buildings not greater than 60 feet (18 288 mm) in length perpendicular to the joist, rafter or truss span, not greater than 6 feet (10 9 mm) in width parallel to the joist span or truss, not greater than two stories in height with each story not greater than 10 feet (08 mm) high, and roof slopes not smaller than : (2-percent slope) or greater than : (100-percent slope). Steel roof framing constructed in accordance with the provisions of this section shall be limited to sites subjected to a maximum design wind speed of 110 miles per hour (209 km/h) Exposure A, B or C and a maximum ground snow load of 0 psf (. kn/m 2 ). R80.1.2 In-line framing. Steel roof framing constructed in accordance with Section R80 shall be located directly in-line with load-bearing studs below with a maximum tolerance of / inch (19.1 mm) between the centerline of the stud and roof joist/rafter. R80.1. Roof trusses. The design, quality assurance, installation and testing of cold-formed steel trusses shall be in accordance with the AISI Standard for Cold-formed Steel Framing-Truss Design (COFS/Truss). R80.2 Structural framing. Load-bearing steel roof framing members shall comply with Figure R80.2(1) and the dimensional and minimum thickness requirements specified in Tables R80.2(1) and R80.2(2). Tracks shall comply with Figure R80.2(2) and shall have a minimum flange width of 1 1 / inches (2 mm). The maximum inside bend radius for 228 2006 NORTH CAROLINA RESIDENTIAL CODE

load-bearing members shall be the greater of / 2 inch (2. mm) or twice the uncoated steel thickness. Holes in roof framing members shall not exceed 1. inches (8 mm) in width or inches (102 mm) in length as shown in Figure R80.2(). Holes shall be permitted only along the centerline of the web of the framing member. Holes shall not be less than 2 inches (610 mm) center-to-center and shall not be located less than 10 inches (2 mm) from the edge of the hole to the edge of the bearing surface or support unless patched in accordance with Section R80..6. R80.2.1 Material. Load-bearing steel framing members shall be cold-formed to shape from structural qualitysheet steel complying with the requirements of one of the following: 1. ASTM A 6; Grades,, 0 and 0 (Classes 1and ). 2. ASTM A 92; Grades,, 0 and 0A.. ASTM A 8; Grades,, 0 and 0 (Classes 1 and ).. Steels that comply with ASTM A 6, except for tensile and elongation, shall be permitted provided the ratio of tensile strength to yield point is at least 1.08 and the total elongation is at least 10 percent for a 2-inch (1 mm) gage length or percent for an 8-inch (20 mm) gage length. R80.2.2 Identification. Load-bearing steel framing members shall have a legible label, stencil, stamp or embossment with the following information as a minimum: 1. Manufacturer s identification. 2. Minimum uncoated steel thickness in inches (mm).. Minimum coating designation.. Minimum yield strength, in kips per square inch (ksi). R80.2. Corrosion protection. Load-bearing steel framing shall have a metallic coating complying with one of the following: 1. A minimum of G 60 in accordance with ASTM A 6. 2. A minimum of AZ 0 in accordance with ASTM A 92.. A minimum of GF 60 in accordance with ASTM A 8. R80.2. Fastening requirements. Screws for steel-to-steel connections shall be installed with a minimum edge distance and center-to-center spacing of 1 / 2 inch (. mm), shall be self drilling tapping, and shall conform to SAE J8. Structural sheathing shall be attached to roof rafters with minimum No. 8 self-drilling tapping screws that conform to SAE J8. Screws for attaching structural sheathing to steel roof framing shall have a minimum head diameter of 0.292 inch (. mm) with countersunk heads and shall be installed with a minimum edge distance of / 8 inch (9. mm). Gypsum board ceilings shall be attached to steel joists with minimum No. 6 screws conforming to ASTM C 9 and shall be installed in accordance with Section R80. For all connections, screws shall extend through the steel a minimum of three exposed threads. All self-drilling tapping screws conforming to SAE J8 shall have a minimum Type II coating in accordance with ASTM B 6. Where No. 8 screws are specified in a steel-to-steel connection, the required number of screws in the connection is permitted to be reduced in accordance with the reduction factors in Table R80.2. when larger screws are used or when one of the sheets of steel being connected is thicker NOMINAL MEMBER SIZE MEMBER DESIGNATION a TABLE R80.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES WEB DEPTH ( MINIMUM FLANGE WIDTH ( MAXIMUM FLANGE WIDTH ( MINIMUM LIP SIZE ( 0S2-t. 1.62 2 0. 0S2-t. 1.62 2 0. 800S2-t 8 1.62 2 0. 1000S2-t 10 1.62 2 0. 00S2-t 1.62 2 0. For SI: 1 inch = 2. mm. a. The member designation is defined by the first number representing the member depth in 1 / 100 inch, the letter s representing a stud or joist member, the second number representing the flange width in 1 / 100 inch, and the letter t shall be a number representing the minimum base metal thickness in mils [see Table R80.2(2)]. TABLE R80.2(2) MINIMUM THICKNE OF COLD-FORMED STEEL ROOF FRAMING MEMBERS For SI: DESIGNATION (mils) MINIMUM UNCOATED THICKNE ( REFERENCED GAGE NUMBER 0.0 20 0.0 18 0.0 68 0.068 1 1 inch = 2. mm, 1 mil = 0.02 mm. 2006 NORTH CAROLINA RESIDENTIAL CODE 229

FIGURE R80.2(1) C-SECTION FIGURE R80.2(2) TRACK SECTION For SI: 1 inch = 2. mm. FIGURE R80.2() WEB HOLES that mils (0.8 mm). When applying the reduction factor, the resulting number of screws shall be rounded up. For SI: SCREW SIZE TABLE R80.2. SCREW SUBSTITUTION FACTOR THINNEST CONNECTED STEEL SHEET (mils) #8 1.0 0.6 #10 0.9 0.62 # 0.86 0.6 1 mil = 0.02 mm. R80. Roof construction. Steel roof systems constructed in accordance with the provisions of this section shall consist of both ceiling joists and rafters in accordance with Figure R80. and fastened in accordance with Table R80.. R80..1 Allowable ceiling joist spans. The clear span of cold formed steel ceiling joists shall not exceed the limits set forth in Table R80..1(1) or R80..1(2). Ceiling joists shall have a minimum bearing length of 1. inches (8 mm) and shall be connected to rafters (heel joint) in accordance with Figure R80..1(1) and Table R80..1(). When continuous joists are framed across interior bearing supports, the interior bearing supports shall be located within 2 inches (610 mm) of midspan of the ceiling joist, and the individual spans shall not exceed the applicable spans in Table R80..1(1) or R80..1(2). Where required in Table R80..1(1) or R80..1(2), bearing stiffeners shall be installed at each bearing location in accordance with Section R80..8 and Figure R80..8. When the attic is to be used as an occupied space, the ceiling joists shall be designed in accordance with Section R0. R80..2 Ceiling joist bracing. The bottom flanges of steel ceiling joists shall be laterally braced in accordance with Section R02. The top flanges of steel ceiling joists shall be laterally braced with a minimum of mil (0.8 mm) C-section, mil (0.8 mm) track section, or 1 1 / 2 inch by mil (8 mm by 0.8 mm) continuous steel strapping as required in Table R80..1(1) or R80..1(2). Lateral bracing shall be installed in accordance with Figure R80.. C-section, tracks or straps shall be fastened to the top flange at each joist with at least one No. 8 screw and shall be fastened to blocking with at least two No. 8 screws. Blocking or bridging (X-bracing) shall be installed between joists in-line with strap bracing at a maximum spacing of feet (68 mm) measured perpendicular to the joists, and at the termination of all straps. The third point bracing span values from Table R80..1(1) or R80..1(2) shall be used for straps installed at closer spacings than third point bracing, or when sheathing is applied to the top of the ceiling joists. R80.. Allowable rafter spans. The horizontal projection of the rafter span, as shown in Figure R80., shall not exceed the limits set forth in Table R80..(1). Wind speeds shall be converted to equivalent ground snow loads in accordance with Table R80..(2). Rafter spans shall be selected based on the higher of the ground snow load or the equivalent snow load converted from the wind speed. When required, a rafter support brace shall be a minimum of 0S2- C-section with maximum length of 8 feet (28 mm) and shall be connected to a ceiling joist and rafter with four No. 10 screws at each end. R80...1 Rafter framing. Rafters shall be connected to a parallel ceiling joist to form a continuous tie between exterior walls in accordance with Figures R80. and R80..1(1) and Table R80..1(). Rafters shall be connected to a ridge member with a minimum 2-inch by 2-inch (1 mm by 1 mm) clip angle fastened with minimum No. 10 screws to the ridge member in accordance with Figure R80...1 and Table R80...1. The clip angle shall have a minimum steel thickness as the rafter member and shall extend the full depth of the rafter member. The ridge member shall be fabricated from a C-sec- 20 2006 NORTH CAROLINA RESIDENTIAL CODE