Converter. Specifications/Instructions. General. Features. Specifications. Dimensions AB-6484

Similar documents
This section is specifically about safety matters

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

SIA, SIB, SIC, SID. User's Manual

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Mounting method DIN rail mounting or screw mounting Screw mounting Mass [g] Material Case: Plastics PCB: FR-4

General Specifications

This section is specifically about safety matters

MODEL: M2DYS SEN TRONIC AG

General Specifications

General Specifications

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

Universal Alarm Indicator

LIGHT TRANSMITTER OPERATION MANUAL. 4 to 20 ma. Model : TR-LXT1A4

SHIMADEN DIGITAL INDICATORS

General Specifications

User s Manual. Model MA5 Distributor (Free Range Type) CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT MODEL AND SUFFIX CODES

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

Tube Facing Tool.

USER MANUAL. WBP314P71 active power transducer. (3-phase 4-wired)

User s Manual Current Probe. IM E 2nd Edition IM E

MS2030 CAT III 600 V A V AUTO RS232

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

Safety Precautions. Copyright / Trademarks

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

User s Manual. Model CA51/71 HANDY CAL (Calibrator) IM CA71-E IM CA71-E

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

User s Manual. Model MS5 Potentiometer Converter (Free Range Type) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

User s Manual. Model MXS Universal Computing Unit (1-input, Isolated 2-output Type) MODEL AND SUFFIX CODES

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

Instruction Manual. Digital Panel Meter Model 3153B

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

General Specifications

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

INSTRUCTION MANUAL CLAMP ON PROBE

INSTRUCTION MANUAL FOR PROGRAMMABLE CONTROLLER PCD-33A

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Power supply CP-D 24/4.2 Primary switch mode power supply

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

General Specifications

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

General Specifications

General Specifications

USER S MANUAL. Rail-mounted temperature transmitter ATL

ProfiScale MULTI Multimeter

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

INVERTER INSTRUCTION MANUAL. 16 bit digital input function. Plug-in option FR-A7AX PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

User s Manual. Model CA51, CA71 HANDY CAL (Calibrator) IM CA71-E. Store this manual in an easily accessible place for quick reference.

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

REV-201М OPERATING MANUAL MULTIFUNCTIONAL TWO-CHANNEL TIME DELAY RELAY. «NOVATEK-ELECTRO» Ltd Intelligent industrial electronics

DM-45 Digital Multimeter

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

Power supply CP-E 24/2.5

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

RT-3 UNIT RELAY 4-POINT TERMINAL

AMM-1022 Digital Multimeter USER`S MANUAL

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

SHIMADEN DIGITAL INDICATORS

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

User s Manual Current Probe IM E. 8th Edition

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

TMP40. User Manual.

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

SAFETY PRECAUTIONS: Before use, read the following safety precautions

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control

Phase-sequence Phase-loss Relay

10-CH Digital Thermometer Module

Models UT350/UT320 Digital Indicating Controllers

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Part No. Z , IB Operation Manual. Pseudo Voice Generator KSG3600

RT-3 UNIT RELAY 4-POINT TERMINAL

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

General Specifications

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

IP Series DUAL POWER AMPLIFIERS

Power supply CP-E 24/20.0

BENNING. CM7 Electrical Tester. Service Information

On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual

MINI-PS AC/24DC/1.3

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

P5201 Universal Programmable Transmitters with Galvanic Isolation

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Temperature Input Module for Zone 1 Series 9482/32

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

1 INTRODUCTION ORDER CODE / INFORMATION

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Transcription:

AB6484 Specifications/Instructions Converter General Model RYY792X series of s offer compact, spacesaving, easy installation with its plugin structure. Each model is modularized for a particular function. Model RYY792X s can be used for signal transmission between instruments, as a controller, for monitoring, and for various other applications. Features Compact, spacesaving, plugin structure. Minimal mounting space. Wide variety of types. Specifications Items Power Insulation resistance Withstand voltage Rated operating conditions Ambient storage & transportation conditions Specifications 85 V AC to 264 V AC, 50 Hz / 60 Hz 100 M or over at 500 V DC (Between input/output and power supply) 2000 V AC for one minute (Between input/output and power supply) Temperature: 5 C to 55 C Humidity: 5 %RH to 90 %RH (Noncondensing) Altitude: 2,000m or Vibration: 4.9 m/s², 5 Hz to 100 Hz Temperature: Humidity: 10 C to 60 C 5 %RH to 90 %RH (Noncondensing) 9.8 m/s², 0 Hz to 60 Hz Vibration: Product Refer to Product Specifications. specifications Dimensions Refer to Figs. 1 and 2. Accessory Socket (See Fig. 2.) Socket: Part No. RYYCS370011P (Though the socket is supplied with Model Auxiliary part RYY792X, the socket can separately be ordered as an auxiliary part.) Dimensions 84 Potentiometer knob for SPAN adjustment Potentiometer knob for ZERO adjustment Main unit 25 8 84 33 Socket Main unit fixing screw Figure 1. Dimensions (mm): With the socket assembled 7.5 4.2 6 18.4 35.2 84 86 Slit for wall mounting (with M4 screw) 30.5 40.5 Input/output terminals 4.2 9.5 29 Figure 2. Dimensions (mm): Socket in front 1 20042017 Azbil Corporation All Rights Reserved.

AB6484 Installation Model RYY792X s are mounted on panels. Install according to the following instructions: Precautions for installation Do not use the product in an atmosphere containing excessive humidity, acidic gases, or corrosive substances. Use the product under the conditions specified in this document. Use dedicated sockets. Installation procedure 1) Mount the socket on the panel with DIN rail or screws. For screwmounting, mounting screws (M4 15 or longer) are additionally required. Mounting dimensions are shown in Figs. 1 and 2. Before mounting the socket, make sure that it is in upright position. (Do not mount it upside down.) 2) Connect the wires to the terminals according to Wires Connection section. Then, assemble the main unit with the socket by carefully inserting the main unit in the front of the socket. Improper insertion (e.g., with the main unit inclined/upside down) can damage the pins of the main unit or the socket. After insertion, fingertighten the main unit fixing screw. Safety Precautions Please read instructions carefully and use the product as specified in this manual. Be sure to keep this manual nearby for quick reference. Restrictions on Use This product was developed, designed, and manufactured for general air conditioning use. Do not use the product in a situation where human life may be at risk or for nuclear applications in radiation controlled areas. If you wish to use the product in a radiation controlled area, please contact Azbil Corporation. Particularly when the product is used in the following applications where safety is required, implementation of failsafe design, redundant design, regular maintenance, etc., should be considered in order to use the product safely and reliably. Safety devices for protecting the human body Start/stop control devices for transportation machines Aeronautical/aerospace machines For system design, application design, instructions for use, or product applications, please contact Azbil Corporation. Azbil Corporation bears no responsibility for any result, or lack of result, deriving from the customer's use of the product. Recommended Design Life It is recommended that this product be used within the recommended design life. The recommended design life is the period during which you can use the product safely and reliably based on the design specifications. If the product is used beyond this period, its failure ratio may increase due to timerelated deterioration of parts, etc. The recommended design life during which the product can operate reliably with the lowest failure ratio and least deterioration over time is estimated scientifically based on acceleration tests, endurance tests, etc., taking into consideration the operating environment, conditions, and frequency of use as basic parameters. The recommended design life of this product is shown in the following table. The recommended design life assumes that maintenance, such as replacement of the limited life parts, is carried out properly.refer to the section on maintenance in this manual. Product RYY792M RYY792A, H, L, N, P, R, V, S RYY792D, B, Y Recommended design life 9 years 13 years 14 years 2

AB6484 Warnings and Cautions WARNING CAUTION Alerts users that improper handling may cause death or serious injury. Alerts users that improper handling may cause minor injury or material loss. Signs Alerts users to possible hazardous conditions caused by erroneous operation or erroneous use. The symbol inside indicates the specific type of danger. (For example, the sign on the left warns of the risk of electric shock.) Notifies users that specific actions are prohibited to prevent possible danger. The symbol inside graphically indicates the prohibited action. (For example, the sign on the left means that disassembly is prohibited.) Instructs users to carry out a specific obligatory action to prevent possible danger. The symbol inside graphically indicates the actual action to be carried out. (For example, the sign on the left indicates general instructions.) WARNING Before wiring, be sure to turn off the power to this product. Failure to do so may result in electric shock or device failure. CAUTION Use this product under the operating conditions (for, humidity, power, vibration, shock, mounting direction, atmosphere, etc.) listed in the specifications. Failure to do so may cause fire or device failure. Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards. All wiring must comply with applicable codes and ordinances. Provide a circuit breaker for the power source of this product. The product does not have a power switch. Use crimp terminals with insulation for connections to the product terminals. Failure to do so may cause short circuit leading to fire or device failure. Firmly tighten the terminal screws. Insufficient tightening of the terminal screws may cause overheating or fire. Dispose of the product as industrial waste in accordance with your local regulations. Do not reuse all or any part of the device. 3

AB6484 Product Specifications Application Model number Converter type Input signal* 1 Output signal* 1 Range Input resistance Range Load resistance Accuracy* 2 Power consumption (VA) Weight (kg) Remarks Ni (508.4 /0 C)/ Current Platinum (JPt) (100 /0 C)/ Current Platinum (Pt) (100 /0 C)/ Current Potentiometer/ Current Voltage/current Current/ voltage Circuit insulation (isolator) 2input high selector 2input low selector RYY792N3001 RYY792N3002 RYY792N3003 RYY792P3011 RYY792P3012 RYY792P3013 RYY792P3021 RYY792P3022 RYY792P3023 RYY792R3061 RYY792V3021 RYY792V3022 RYY792V3023 RYY792V3024 RYY792A3077 Ni/I JPt/I Pt/I POT/I V/I I/V Ni 0 to 50 C 0 to 100 C 20 to 80 C JPt 0 to 50 C 0 to 100 C 20 to 80 C Pt 0 to 50 C 0 to 100 C 20 to 80 C 0100 to 10 k 0 to 10 mv 0 to 100 mv 1 to 5 V 0 to 10 V 4 to 20mA* 3 750 or 4 to 20 ma* 3 750 or 4 to 20 ma* 3 750 or 4 to 20 ma* 3 750 or 1 M or higher 4 to 20 ma* 3 750 or 4 to 20 ma 250 0 to 100 mv* 4 100 k or higher RYY792S3041 Isolator 4 to 20 ma 250 4 to 20 ma* 3 750 or RYY792H3091 RYY792L3092 High selector Low selector 4 to 20 ma 250 4 to 20 ma* 3 750 or 4 to 20 ma 250 4 to 20 ma* 3 750 or Limiter RYY792Y3051 Limiter 4 to 20 ma 250 4 to 20 ma* 3 750 or Ratio bias RYY792B3081 Monitor switch RYY792M3055 24 V DC power supply RYY792D3001 Ratio bias (positive gradient, negative gradient) Monitor switch 24 V DC power supply 4 to 20 ma 250 4 to 20 ma* 3 750 or 4 to 20 ma 250 2 Potential free (NO/NC) contacts 24 V DC Contact rating 250 V AC, 3 A 30 V DC, 5 A Max. 22 ma 0.15%FS 3.5 0.15 0.15%FS 3.5 0.15 0.15%FS 3.5 0.15 0.2 %FS 3 0.15 0.1 %FS 3 0.15 0.1 %FS 3 0.15 Setting range ZERO side: 0 to 50 % SPAN side: 50 to 100 % 0.1 %FS 3 0.15 0.1 %FS 3.5 0.15 0.1 %FS 3.5 0.15 0.2 %FS 4 0.15 0.2 %FS when Ratio K=1 Bias B=0 0.5 %FS (Setting accuracy) 24 to 28 V DC 4 0.15 3.5 0.15 5 0.15 Setting range High limit: 10 to 105 % Low limit: 10 to 105 % Equation and setting range Y = KX B (positive) Io = KX B F (negative) K=10 to 400 % (positive) K=10 to 400 % (negative) B = 100 to 100 % F = 100 % Setting range 0 to 99 % (1 % step) Without insulation (Voltage range under no allowable load) Reverser RYY792A3100 Reverser 4 to 20 ma 250 4 to 20 ma* 3 750 or 0.1 %FS 3 0.15 Notes: 1. The voltage/current (V/A) input and output signals listed above are both indicated in direct current (DC). 2. The Accuracy indicate differences between input and output under the rated operating conditions: 25 C ± 5 C room, 100 V AC rated voltage, rated frequency ±1 Hz 3. Output signals will proportionally follow input signals when the input signals are out of the rated range. That is, output signals can be out of the 4 to 20 ma range. 4. Output signals will proportionally follow input signals when the input signals are out of the rated range. That is, output signals can be out of the 0 to 100 mv range. 4

AB6484 Wire Connections Wire Specifications Select the appropriate size, length, and type of wires according to the following table. Converter type Input wiring Output wiring Power line Converters (JPt/I, Pt/I) 5 or per wire Isolator, limiter, monitor switch, 24 V DC power supply, reverser, high selector, low selector, ratio 3 or per wire bias, and s (POT/I, I/V, Ni/I) 15 V 010 V 3 or per wire 3 or per wire 3 or per wire V/I 010 mv 3 or per wire (twocore shield wire) 0100 mv 3 or per wire Note: If noise sources cannot be avoided, use shield wires. Precautions for connecting wires Install wiring complying with the indoor wiring rules and the applicable laws and regulations. Connection to the terminals Resistance Model RYY792N 3001 3002 3003 Model RYY792P 3011 3012 3013 Model RYY792P 3021 3022 3023 8 7 6 Temp. sensor A B B Output <Example of wiring for using the 1 5 V DC check terminals> Potentiometer Model RYY792R 3061 Max. Min. Figure 32. Connection diagram 24 V DC power supply Model RYY792D 3001 Figure 34. Connection diagram Output Field Instrument Figure 31. Connection diagram 2input high selector Model RYY792H 3091 2input low selector Model RYY792L 3092 Figure 33. Connection diagram Input 2 Input 1 Output Wiring for using the 1 5 V DC check terminals* 1 420 ma DC output Twowire transmitter 15 V DC Testing terminal Figure 35. Connection diagram 5 Figure 36. Connection diagram Load resistance observed by field instrument = 250 Ω Input resistance of receiver 1 Input resistance of receiver 2 V/I Model RYY792V 3021 3022 3023 3024 Ratio bias Model RYY792B 3081 Reverser Model RYY792A 3100 Isolator Model RYY792S 3041 Limiter Model RYY792Y 3051 I/V Model RYY792A 3077 Monitor switch Model RYY792M 3055 Input Figure 38. Connection diagram Input 1 Output Figure 37. Connection diagram *1 Signal (420 ma) of twowire transmitters can be checked by the 15 V DC testing terminals. However an internal resistance (250 Ω) will be added, so be aware that the total resistance should be within the twowire transmitter s allowable load resistance (see Fig. 36).

AB6484 Adjustment Precautions for making adjustment IMPORTANT: After power on, allow minimum 30 min warmup operation before starting normal operation. This product is adjusted before shipment. Do not turn the potentiometer knobs with paint locks. When adjusting the potentiometer knobs on the front of the unit, use the appropriate size driver. Do not turn the potentiometer knobs beyond their limits. Use standard lead wires to be connected to the monitor terminal. Do not touch components other than the potentiometer knobs and the setting switches when making adjustments. Adjusting the POT/I Set the effective sliding range of the potentiometer as: r 1 R r 2 UP 0 100% R: Effective sliding range r 1 : Residual resistance at 0 % side r 2 : Residual resistance at 100% side As the left figure shows, set the 0 % and 100 % points to make the residual resistances of the potentiometer be r 1 = r 2. Zero adjustment: Set the potentiometer sliding position at the 0 % point as shown in the figure above, and connect to the. Then, turn the ZERO potentiometer adjustment knob until the output is set to 4 ma. Span adjustment: Similarly, shift the potentiometer sliding position to the 100 % point as shown in the figure above. Under this condition, turn the SPAN potentiometer adjustment knob until the output is set to 20 ma. Potentiometer knob for SPAN adjustment Potentiometer knob for ZERO adjustment ZERO adjustment range: 0 to 50 % FS SPAN adjustment range: 50 to100 % FS (Reconfirm point zero and repeat the procedure 1 and 2 to ensure the s accuracy.) Figure 4. Front panel of the POT/I Monitor switch setup Monitor switch is set by turning the front thumbwheel switches with a driver. Output 1 is for high alarm and Output 2 is for low alarm. Monitor LED turns on when the relay coil is excited. Output 1 is excited when Input > Setpoint, and Output 2 is excited when Input < Setpoint. Output 1 (64) ON (65) ON Output 2 (78) ON (711) ON Input Operation during power failure: (%) 0 50 10 (64) Setpoint 2 Setpoint 1 (711) ON Figure 5. Alarm trip operation Output 1 for high alarm Output 2 for low alarm Figure 6. Front panel of the monitor switch Limiter setup How to set high limit: Switch the high/low limit selector to the upper side. The high/low limit display shows the high limit (10 to 105 %). Press UP/DOWN control for the value setup. The polarity indicator LED glows RED when the set value is in positive range, and glows GREEN in negative range. How to set low limit: Switch the high/low limit selector to the downside. The high/low limit display shows the low limit (10.0 to 105 %). Press UP/DOWN control for the value setup. The polarity indicator LED glows RED when the set value is in positive range, and glows GREEN in negative range. The factory preset setting values for high limit is 100 %, and low limit is 0 %. 6

AB6484 Potentiometer knob for ZERO adjustment Polarity indicator LED Up/down control of setpoint Potentiometer knob for SPAN adjustment High/low limit selector (top: high limit, bottom: low limit) High/low limit display Figure 7. Front panel of the limiter Ratio bias setup How to set the ratio: Switch the ratio/bias selector to the RATIO side. The ratio/bias display shows the ratio (0.10 to 4.00). Press UP/DOWN control for the value setup. The polarity indicator LED glows RED when the set value is in the positive gradient characteristic, and glows GREEN in the negative gradient characteristic. How to set the bias: Switch the ratio/bias selector to the BIAS side. The ratio/bias display shows the bias (0 to100 %). Press UP/DOWN control for the value setup. The polarity indicator LED glows RED when the set value is positive, and glows GREEN when negative. Potentiometer knob for ZERO adjustment Potentiometer knob for SPAN adjustment Polarity indicator LED Up/down control of setpoint Ratio/bias selector (top: ratio, bottom: bias) Ratio/bias display Figure 8. Front panel of the ratio bias Equation: Y = KX B (positive gradient characteristic) Y = KX B F (negative gradient characteristic) where Y = Output signal (%) K = Ratio (Linear characteristics, positive gradient: 0.1 to 4.00 / negative gradient: 0.1 to 4.00) X = Input signal (approx.10 to 120 %) B = Bias (100 to 100 %) F = 100% Fine adjustment: Follow the procedure below for fine adjustment. 1) Under the equation: Xo = KX B (positive gradient) or Xo = KX B F (negative gradient), shift the input signal value Xi to zero point side and adjust the output Y to the result with ZERO adjustment. 2) Shift the input signal value X to the span point side and adjust the output Y to the result with SPAN adjustment. 3) Shift again the input signal value X to zero point side and check the output Y on the zero point side. 4) If the output Y is changed, repeat the procedure 1 through 3 again for adjustment. The unit is set and calibrated for shipment as: Ratio (K)=1, Bias (B)=0% 7

AB6484 Handling Precautions IMPORTANT: This is a precision device. Ensure careful handling. Any mishandling or accidental dropping will damage the product. As the product utilizes electronic components, do not place in wet or humid locations. The plastic housing may be deformed if being exposed to high heating. This is a precision device with high performance and high reliability. Do not disassemble or remodel. Inspection and Maintenance Inspect each setting every 2 years. Install this product in a panel cabinet. Additionally, always keep the panel cabinet accessible only to people with sufficient knowledge concerning electrical equipment. This product complies with the following harmonised standards of the Electromagnetic Compatibility Directive (EMCD), the Low Voltage Directive (LVD) and the Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment Directive (RoHSD). EMCD: EN 613261 Class A, Table 2 (for use in an industrial electromagnetic environment) LVD: EN 610101 Overvoltage category II Pollution degree 2 RoHSD: EN 50581 Specifications are subject to change without notice. Building Systems Company http://www.azbil.com/ Rev. 8.0 Dec. 2017 8 AB6484.