Power Distribution System SVS02

Similar documents
Power Distribution System SVS02

Power Distribution System SVS20

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1

Power Distribution System SVS18

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker ESS1 for System SVS1

Power distribution system SVS25

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Protector ESX10-T

Electronic Circuit Protector ESX10

Electronic circuit protector REX12

REX12 Electronic Circuit Protector

Electronic circuit breaker ESS30-Sxxx-DC24V

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Smart Power Relay E I...

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Datasheet. Electronic Circuit Protection ESX10-T

REX12 Electronic Circuit Protector

Solid State Remote Power Controller E

PHOENIX CONTACT

PHOENIX CONTACT

PHOENIX CONTACT - 09/2009

Through and Ground Conductor Terminal Blocks 290 Series

PowerPlex Compact Module PP-C-COM24

Wireless multizone receiver RDE-MZ6

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

LED Driver Compact fixed output. Udriver LC 25/30/35/40W 600/700/800/900mA fixc SC ADV ADVANCED series

Measuring current transformers of the W AB(P) series

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

No-wear isolation of potentials in terminal block design

Adjustable Digital Process Instrument MDK480

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN

Switching power supplies CP range, Linear power supplies CP-L range. Content

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Measuring current transformers of the W, W series

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Power Distribution Blocks with Short-Circuit Current Ratings

Type CP-S, CP-C & CP-A Switch mode

E-STOP relays, safety gate monitors

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

CP-T range Product group picture

38 Series - Relay Interface Modules A

Advantages. Applications

LED Driver Compact fixed output

SINEAX V 604s Programmable multifunctional transmitter

LED Driver Compact fixed output

MINI-PS AC/2X15DC/1

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

CP-T range Benefits and advantages

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Overcurrent Protection / 7SJ45

Data sheet. W-Series WDU 2.5

27/04/2015

Measuring current transformers of the W B series

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Output of three-phase motors at 50 Hz and 400 V

Thermistor motor protection relays

EA16, EB16, EA17, EA19

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

QUINT-PS/ 1AC/24DC/20

05/09/2014

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

MOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry.

Analog signal converters CC range

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

E-STOP relays, safety gate monitors

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Control module CP-A CM

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

LR Position Switches TECHNICAL DATASHEET

83 Series - Modular timers 16 A. Features

Capacitor Switching Contactors

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

Switching Devices Contactors and Contactor Assemblies for Switching Motors

Page 13-2 Page Page 13-7

Data sheet. W-Series WDU 4 BL

Modeion MOULDED CASE CIRCUIT BREAKERS BL1000S

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Power Supplies 3. SDN-C Compact DIN Rail Series

Title page, Product innovations Product innovations. 14 OBO Neuheiten 2016 / en / 01/03/2016 (LLExport_04360) / 01/03/2016

EAO Product Information. Series 84

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

E-STOP relays, safety gate monitors

Data sheet. W-Series WDU 10

QUINT-PS/ 3AC/24DC/40

TZIF 4. Current-to-Pulse Converter 10/ EN

Transcription:

Power Distribution System SV2 Description The ETA power distribution system SV2 is designed to accommodate the electronic circuit breaker series ESS20003 or electronic circuit protector ESX0. It distributes the current supplied by a switch mode power supply up to 40 A to 4, 8, 2 or channels. Input connections are via screw terminals. The individual circuit breakers can be plugged in. Loads are connected via springloaded screwless terminals. The power distribution includes integral wiring of the signalisation of the individual channels which can be combined to a group signal. The SV2 can be snapped onto a DIN symmetrical rail. Suitable for l ESS20003 l ESX003 l 220S2 Ordering information Type SV2 Power distribution system for ESS20003 l short circuit current limited DC 24 V applications l max. 40 A continuous load l two integral circuit breakers (CB and ): overcurrent protection of group signalisation of power distribution system, red LED glashes upon trip of CB l 2 insulated wire bridges Y 303 88 08 included l without jumpers SBSP0A (for unused positions) Version, max. number of circuit breakers ESS20003 on the power distribution system 04 4 channels (F...F4) 08 8 channels (F...F8) 2 2 channels (F...F2) channels (F...F) Screw terminals for power supply DC 24 V P30 3 loopthrough terminals (X 2) max. 0 mm 2 for DC 24 V () / DC 24 V () / functional earth Load outputs per channel (F.. Fn, n = 04, 08, 2, ) L50 5 load outputs per channel, max. 8 A each l () group output () internally bridged over all channels l () protected load output (), per channel l () DC 24 V () l () DC 24 V () l () functional earth Signal outputs S5 signal terminal () for group signal, 5pole, complete with plugin terminal, wiring 5 x max. 2 mm 2 / without connector sleeve, max. 0 A: l () internal DC 24 V supply for signalisation via insulated wire bridge from () to () l () external supply possible DC 24 V for signalisation l () signal output group signalisation l () additional output DC 24 V () l () additional functional earth Control input E00 without control input Fitting variants B0 complete with screwless springloaded terminals, (max. 2 mm 2, without connector sleeve) (standard) B20 complete with plugin screw terminals (max. 2 mm 2, without connector sleeve) SV2 P30 L50 S5 E00 B0 Technical data SV208... l Modular Power distribution system for shortcircuit limited DC 24 V applications up to max. 40 A continuous load, max. voltage DC 32 V. l Three screw terminals (max. 0 mm 2 /AWG 8) for: DC 24 V () = X 2 DC 24 V () = X 2 (functional earth) = X 2 for connecting the DC 24 V power supply max. 40 A l Modular design ESS20positions F...F4 (..F8,...F2 or...f): SV204 / 4 channels / F...F4 = Kl. X...X4 SV208 / 8 channels / F...F8 = Kl. X...X8 SV22 / 2 channels / F...F2 = Kl. X...X2 SV2 / channels / F...F = Kl. X...X l 5 load outputs per channel complete with Combicon screwless connectors, wiring 5 x max. 2 mm 2 (AWG 4)/ without connector sleeve max. 8 A: () group output (), internally bridged across all channels () load output (), per channel () DC 24 V () () DC 24 V () () functional earth l Signal terminal () for group signal complete with Combicon screwless connectors, wiring 5 x max. 2 mm 2 (AWG 4)/ without connector sleeve, max. 0 A (signal contact ESS20): () internal DC 24 V supply for signalisation of terminal X 2 via insulated jumper from () to (), protected by () external supply possible DC 24 V for signalisation, protected by CB () signal output group signalisation () additional output DC 24 V () () additional functional earth l Selective overcurrent protection CB and for group signalisation of the power distribution system, red LED blinks after CB has tripped (see schematic diagram). Reset of circuit breakers: momentarily press red actuator button l Protection class to: IP20 l Insulation coordination to IEC 0934: 0 kv / pollution degree 2 l Dielectric strength AC 500 V l Temperature range: 0..0 C (without condensation) l for DIN symmetrical rail mounting EN 50022 35 x 7 l Dimensions: see dimensional drawing www.eta.de

Power Distribution System SV2 Dimensions SV2 Insulated wire bridge, not fitted (2 pcs enclosed) Rail EN 5002235x7,5 (not supplied) 52 2.05 44..75 F4 = 09 F4 = 4 F8 = 7 F8 =.75 F2 = 233 F2 = 99 F = 295 F =.3 www.eta.de Typ: SV2 B0 B20 05 45 CB X2 X2 X2 NUR KURZ DRUECKEN ONLY PUSH BRIEFLY F F2 F3 F4 F5 F F7 F8 F9 F0 F F2 F3 F4 F5 F X3 X X8 X9 X0 X X2 X3 X4 X5 X X X2 X4 X5 X7 red LED blinks after CB has tripped screw terminals DC 24 V power supply 5.0 load outputs screwless springloaded terminals This is a metric design and millimeter dimensions take precedence ( mm ) inch Schematic diagram SV2(n) n = 04, 08, 2, *) see application example for insulated wire bridge *) SO Line () GND () Line () GND () Line () GND () Line () GND () LOAD (L) LOAD (L) LOAD (L) LOAD (L) X2 X2 ESS20003 ESS20003 ESS20003 ESS20003 X2 CB LED V blinks after CB has tripped : no visual indication 2 3 V 2 3 V2 X *) X2 X3 Xn R Circuit breakers CB and : shown in tripped condition F F2 F3 Fn 2 www.eta.de

Power Distribution System SV2 Dimensions SV204, fitted with ESS20003 0 2 red LED blinks after CB has tripped 52 02 (05) 2.05 4.02 (43) d Elektronischer Schutzschalter Electronic Supplementary Protector 003DC24 VA/2A Insulated wire bridge, not fitted (2 pcs enclosed) 05 45 Rail EN 5002235x7,5 (not supplied) 09 4 www.eta.de Typ: SV204 B0 B20 X2 X2 X2 CB NUR KURZ DRUECKEN ONLY PUSH BRIEFLY F F2 F3 F4 X X2 X3 X4 screw terminals DC 24 V power supply load outputs screwless springloaded terminals This is a metric design and millimeter dimensions take precedence ( mm ) inch www.eta.de 3

Power Distribution System SV2 Dimensions SV204, fitted with ESX003 70 2.7 Insulated wire bridge 05 45 09 4 5.0 SO 05 45 X2 X2 X2 F F2 F3 F4 L S L L screw terminals power supply load outputs screwless springloaded terminals 4 www.eta.de

Power Distribution System SV2 Application example for jumper to replace Application example for insulated wire bridge The signalling pathway of the group signalisation is as follows: feedin of DC 24 V potential in ( = terminal 3) via inbuilt overcurrent protection CB via all signal contacts of the fitted circuit breakers type ESS20003 back to signal output of group signalisation ( = terminal 3) Terminal (group signalisation) wire bridge from () to () internal DC24V feed for signalisation Thus plus potential of terminal X2 is connected to () In operating condition (i.e. all circuit breakers plugged in and functional) the signalling pathway () to () is closed. If the distribution rail is not completely fitted with ESS20003, the open pathway () to () may be closed by means of a jumper type SBSP0A www.eta.de Ty p: SV204 B 0 B2 0 X2 X2 X2 CB www.eta.de Typ: SV204 B0 B20 Signalbrücke Signal loop NUR KURZ DRUECKE N ONLY PUSH BRIEFL Y F F2 F3 F4 X X2 X3 X4 X2 X2 X2 CB NUR KURZ DRUECKEN ONLY PUSH BRIEFLY F F2 F3 F4 X X2 X3 X4 Terminal X Protected load output () of CBE position F takes over protection of () terminals of all CBEs F2 up to Fn (n= 04, 08, 2, ) Accessories Jumper SBSP0A Germany top view Insulated wire bridge Y 303 88 08 Two insulated wire bridges are supplied with the power distribution system. They may be used for: 0 70 0 2.7 Signalbrücke Signal loop SBSP0A www.eta.de xxxx AC 240 V / DC 5 V, A 3 4 2 0 2 Signalbrücke Signal loop 2 84 Channel : internal DC 24 V supply for signalisation wire bridge from () to () Signal circuit () to () protected by Signal circuit () to (SO) protected by CB Channel X: Protected load output () of CBE position F takes over protection of () terminals of all CBEs F2 up to Fn (n= 04, 08, 2, ) terminals 34 bridged blade terminals DIN 4244A 0.8 This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. www.eta.de 5

www.eta.de