Power Distribution System SV2 Description The ETA power distribution system SV2 is designed to accommodate the electronic circuit breaker series ESS20003 or electronic circuit protector ESX0. It distributes the current supplied by a switch mode power supply up to 40 A to 4, 8, 2 or channels. Input connections are via screw terminals. The individual circuit breakers can be plugged in. Loads are connected via springloaded screwless terminals. The power distribution includes integral wiring of the signalisation of the individual channels which can be combined to a group signal. The SV2 can be snapped onto a DIN symmetrical rail. Suitable for l ESS20003 l ESX003 l 220S2 Ordering information Type SV2 Power distribution system for ESS20003 l short circuit current limited DC 24 V applications l max. 40 A continuous load l two integral circuit breakers (CB and ): overcurrent protection of group signalisation of power distribution system, red LED glashes upon trip of CB l 2 insulated wire bridges Y 303 88 08 included l without jumpers SBSP0A (for unused positions) Version, max. number of circuit breakers ESS20003 on the power distribution system 04 4 channels (F...F4) 08 8 channels (F...F8) 2 2 channels (F...F2) channels (F...F) Screw terminals for power supply DC 24 V P30 3 loopthrough terminals (X 2) max. 0 mm 2 for DC 24 V () / DC 24 V () / functional earth Load outputs per channel (F.. Fn, n = 04, 08, 2, ) L50 5 load outputs per channel, max. 8 A each l () group output () internally bridged over all channels l () protected load output (), per channel l () DC 24 V () l () DC 24 V () l () functional earth Signal outputs S5 signal terminal () for group signal, 5pole, complete with plugin terminal, wiring 5 x max. 2 mm 2 / without connector sleeve, max. 0 A: l () internal DC 24 V supply for signalisation via insulated wire bridge from () to () l () external supply possible DC 24 V for signalisation l () signal output group signalisation l () additional output DC 24 V () l () additional functional earth Control input E00 without control input Fitting variants B0 complete with screwless springloaded terminals, (max. 2 mm 2, without connector sleeve) (standard) B20 complete with plugin screw terminals (max. 2 mm 2, without connector sleeve) SV2 P30 L50 S5 E00 B0 Technical data SV208... l Modular Power distribution system for shortcircuit limited DC 24 V applications up to max. 40 A continuous load, max. voltage DC 32 V. l Three screw terminals (max. 0 mm 2 /AWG 8) for: DC 24 V () = X 2 DC 24 V () = X 2 (functional earth) = X 2 for connecting the DC 24 V power supply max. 40 A l Modular design ESS20positions F...F4 (..F8,...F2 or...f): SV204 / 4 channels / F...F4 = Kl. X...X4 SV208 / 8 channels / F...F8 = Kl. X...X8 SV22 / 2 channels / F...F2 = Kl. X...X2 SV2 / channels / F...F = Kl. X...X l 5 load outputs per channel complete with Combicon screwless connectors, wiring 5 x max. 2 mm 2 (AWG 4)/ without connector sleeve max. 8 A: () group output (), internally bridged across all channels () load output (), per channel () DC 24 V () () DC 24 V () () functional earth l Signal terminal () for group signal complete with Combicon screwless connectors, wiring 5 x max. 2 mm 2 (AWG 4)/ without connector sleeve, max. 0 A (signal contact ESS20): () internal DC 24 V supply for signalisation of terminal X 2 via insulated jumper from () to (), protected by () external supply possible DC 24 V for signalisation, protected by CB () signal output group signalisation () additional output DC 24 V () () additional functional earth l Selective overcurrent protection CB and for group signalisation of the power distribution system, red LED blinks after CB has tripped (see schematic diagram). Reset of circuit breakers: momentarily press red actuator button l Protection class to: IP20 l Insulation coordination to IEC 0934: 0 kv / pollution degree 2 l Dielectric strength AC 500 V l Temperature range: 0..0 C (without condensation) l for DIN symmetrical rail mounting EN 50022 35 x 7 l Dimensions: see dimensional drawing www.eta.de
Power Distribution System SV2 Dimensions SV2 Insulated wire bridge, not fitted (2 pcs enclosed) Rail EN 5002235x7,5 (not supplied) 52 2.05 44..75 F4 = 09 F4 = 4 F8 = 7 F8 =.75 F2 = 233 F2 = 99 F = 295 F =.3 www.eta.de Typ: SV2 B0 B20 05 45 CB X2 X2 X2 NUR KURZ DRUECKEN ONLY PUSH BRIEFLY F F2 F3 F4 F5 F F7 F8 F9 F0 F F2 F3 F4 F5 F X3 X X8 X9 X0 X X2 X3 X4 X5 X X X2 X4 X5 X7 red LED blinks after CB has tripped screw terminals DC 24 V power supply 5.0 load outputs screwless springloaded terminals This is a metric design and millimeter dimensions take precedence ( mm ) inch Schematic diagram SV2(n) n = 04, 08, 2, *) see application example for insulated wire bridge *) SO Line () GND () Line () GND () Line () GND () Line () GND () LOAD (L) LOAD (L) LOAD (L) LOAD (L) X2 X2 ESS20003 ESS20003 ESS20003 ESS20003 X2 CB LED V blinks after CB has tripped : no visual indication 2 3 V 2 3 V2 X *) X2 X3 Xn R Circuit breakers CB and : shown in tripped condition F F2 F3 Fn 2 www.eta.de
Power Distribution System SV2 Dimensions SV204, fitted with ESS20003 0 2 red LED blinks after CB has tripped 52 02 (05) 2.05 4.02 (43) d Elektronischer Schutzschalter Electronic Supplementary Protector 003DC24 VA/2A Insulated wire bridge, not fitted (2 pcs enclosed) 05 45 Rail EN 5002235x7,5 (not supplied) 09 4 www.eta.de Typ: SV204 B0 B20 X2 X2 X2 CB NUR KURZ DRUECKEN ONLY PUSH BRIEFLY F F2 F3 F4 X X2 X3 X4 screw terminals DC 24 V power supply load outputs screwless springloaded terminals This is a metric design and millimeter dimensions take precedence ( mm ) inch www.eta.de 3
Power Distribution System SV2 Dimensions SV204, fitted with ESX003 70 2.7 Insulated wire bridge 05 45 09 4 5.0 SO 05 45 X2 X2 X2 F F2 F3 F4 L S L L screw terminals power supply load outputs screwless springloaded terminals 4 www.eta.de
Power Distribution System SV2 Application example for jumper to replace Application example for insulated wire bridge The signalling pathway of the group signalisation is as follows: feedin of DC 24 V potential in ( = terminal 3) via inbuilt overcurrent protection CB via all signal contacts of the fitted circuit breakers type ESS20003 back to signal output of group signalisation ( = terminal 3) Terminal (group signalisation) wire bridge from () to () internal DC24V feed for signalisation Thus plus potential of terminal X2 is connected to () In operating condition (i.e. all circuit breakers plugged in and functional) the signalling pathway () to () is closed. If the distribution rail is not completely fitted with ESS20003, the open pathway () to () may be closed by means of a jumper type SBSP0A www.eta.de Ty p: SV204 B 0 B2 0 X2 X2 X2 CB www.eta.de Typ: SV204 B0 B20 Signalbrücke Signal loop NUR KURZ DRUECKE N ONLY PUSH BRIEFL Y F F2 F3 F4 X X2 X3 X4 X2 X2 X2 CB NUR KURZ DRUECKEN ONLY PUSH BRIEFLY F F2 F3 F4 X X2 X3 X4 Terminal X Protected load output () of CBE position F takes over protection of () terminals of all CBEs F2 up to Fn (n= 04, 08, 2, ) Accessories Jumper SBSP0A Germany top view Insulated wire bridge Y 303 88 08 Two insulated wire bridges are supplied with the power distribution system. They may be used for: 0 70 0 2.7 Signalbrücke Signal loop SBSP0A www.eta.de xxxx AC 240 V / DC 5 V, A 3 4 2 0 2 Signalbrücke Signal loop 2 84 Channel : internal DC 24 V supply for signalisation wire bridge from () to () Signal circuit () to () protected by Signal circuit () to (SO) protected by CB Channel X: Protected load output () of CBE position F takes over protection of () terminals of all CBEs F2 up to Fn (n= 04, 08, 2, ) terminals 34 bridged blade terminals DIN 4244A 0.8 This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. www.eta.de 5