An experimental vital signs detection radar using low-if heterodyne architecture and single-sideband transmission

Similar documents
A 24 GHz integrated SiGe BiCMOS vital signs detection radar front-end

Wireless Bio- medical Sensor Network for Heartbeat and Respiration Detection

A Passive X-Band Double Balanced Mixer Utilizing Diode Connected SiGe HBTs

Simplified, high performance transceiver for phase modulated RFID applications

INTRODUCTION TO TRANSCEIVER DESIGN ECE3103 ADVANCED TELECOMMUNICATION SYSTEMS

A 5.8-GHz microwave (vital-signs) Doppler radar (for non-contact human vital-signs detection)

A 2GHz, 17% tuning range quadrature CMOS VCO with high figure of merit and 0.6 phase error

Simple high sensitivity wireless transceiver

Compact microstrip bandpass filter with tunable notch

Session 3. CMOS RF IC Design Principles

Today s mobile devices

Encoding of inductively measured k-space trajectories in MR raw data

Log-periodic dipole antenna with low cross-polarization

ANALOG COMMUNICATION

Analysis and design of lumped element Marchand baluns

A Practical FPGA-Based LUT-Predistortion Technology For Switch-Mode Power Amplifier Linearization Cerasani, Umberto; Le Moullec, Yannick; Tong, Tian

A 5 GHz CMOS Low Power Down-conversion Mixer for Wireless LAN Applications

Scalable Front-End Digital Signal Processing for a Phased Array Radar Demonstrator. International Radar Symposium 2012 Warsaw, 24 May 2012

Remote Monitoring of Heart and Respiration Rate Using a Wireless Microwave Sensor

Fiber-wireless links supporting high-capacity W-band channels

This article reports on

On-chip antenna integration for single-chip millimeterwave FMCW radars Adela, B.B.; Pual, P.T.M; Smolders, A.B.

Receiver Architecture

Radio Receiver Architectures and Analysis

Document Version Publisher s PDF, also known as Version of Record (includes final page, issue and volume numbers)

Measurement Setup for Phase Noise Test at Frequencies above 50 GHz Application Note

Design and Measurement of a 2.45 Ghz On-Body Antenna Optimized for Hearing Instrument Applications

EE470 Electronic Communication Theory Exam II

Making Noise in RF Receivers Simulate Real-World Signals with Signal Generators

Speed your Radio Frequency (RF) Development with a Building-Block Approach

Aalborg Universitet. Published in: Antennas and Propagation (EuCAP), th European Conference on

A low-if 2.4 GHz Integrated RF Receiver for Bluetooth Applications Lai Jiang a, Shaohua Liu b, Hang Yu c and Yan Li d

Termination Insensitive Mixers By Howard Hausman President/CEO, MITEQ, Inc. 100 Davids Drive Hauppauge, NY

Scanning laser Doppler vibrometry

ISSCC 2003 / SESSION 20 / WIRELESS LOCAL AREA NETWORKING / PAPER 20.2

Two octaves bandwidth passive balun for the eleven feed for reflector antennas Zamanifekri, A.; Yang, J.

Low-Profile Fabry-Pérot Cavity Antenna with Metamaterial SRR Cells for Fifth Generation Systems

RF/IF Terminology and Specs

Separation of common and differential mode conducted emission: Power combiner/splitters

Lecture 15: Introduction to Mixers

Beyond 100 Gbit/s wireless connectivity enabled by THz photonics

System Level Design of a Continuous-Time Delta-Sigma Modulator for Portable Ultrasound Scanners

Receiver Architectures

Self-Resonant Electrically Small Loop Antennas for Hearing-Aids Application

Limitations in distance and frequency due to chromatic dispersion in fibre-optic microwave and millimeter-wave links

CONTINUOUS-WAVE (CW) Doppler radars have been

ALMA MEMO #360 Design of Sideband Separation SIS Mixer for 3 mm Band

Simulating and Testing of Signal Processing Methods for Frequency Stepped Chirp Radar

10 GHz Microwave Link

Novel Electrically Small Spherical Electric Dipole Antenna

A NOVEL SCHEME FOR OPTICAL MILLIMETER WAVE GENERATION USING MZM

Lecture 6 SIGNAL PROCESSING. Radar Signal Processing Dr. Aamer Iqbal Bhatti. Dr. Aamer Iqbal Bhatti

Wideband Receiver for Communications Receiver or Spectrum Analysis Usage: A Comparison of Superheterodyne to Quadrature Down Conversion

9 Best Practices for Optimizing Your Signal Generator Part 2 Making Better Measurements

Microwave Radiometer Linearity Measured by Simple Means

Residual Phase Noise Measurement Extracts DUT Noise from External Noise Sources By David Brandon and John Cavey

A Comparative Analysis between Homodyne and Heterodyne Receiver Architecture Md Sarwar Hossain * & Muhammad Sajjad Hussain **

THE BASICS OF RADIO SYSTEM DESIGN

Combining filters and self-interference cancellation for mixer-first receivers in Full Duplex and Frequency-Division Duplex transceiver systems

Code No: R Set No. 1

Introduction to Receivers

Evaluation of RF power degradation in microwave photonic systems employing uniform period fibre Bragg gratings

Further development of synthetic aperture real-time 3D scanning with a rotating phased array

A Waveguide Transverse Broad Wall Slot Radiating Between Baffles

ADI 2006 RF Seminar. Chapter II RF/IF Components and Specifications for Receivers

Comparison of Simple Self-Oscillating PWM Modulators

A HETERODYNE SIX-PORT FMCW RADAR SENSOR ARCHITECTURE BASED ON BEAT SIGNAL PHASE SLOPE TECHNIQUES

Addressing Carrier Aggregation with Narrow-band Tunable Antennas Barrio, Samantha Caporal Del; Morris, Art; Pedersen, Gert F.

System grounding of wind farm medium voltage cable grids

Linearity Improvement Techniques for Wireless Transmitters: Part 1

Continuous Wave Radar

ELEN 701 RF & Microwave Systems Engineering. Lecture 2 September 27, 2006 Dr. Michael Thorburn Santa Clara University

ISSCC 2006 / SESSION 10 / mm-wave AND BEYOND / 10.1

AN X-BAND FREQUENCY AGILE SOURCE WITH EXTREMELY LOW PHASE NOISE FOR DOPPLER RADAR

ELT Receiver Architectures and Signal Processing Exam Requirements and Model Questions 2018

Microwave Metrology -ECE 684 Spring Lab Exercise I&Q.v3: I&Q Time and Frequency Domain Measurements

PHASE NOISE MEASUREMENT SYSTEMS

LOW-POWER RADAR SYSTEM FOR REMOTE DETECTION OF HEARTBEAT AND RESPIRAITON USING DOUBLE-SIDEBAND TRANSMISSION AND FREQUENCY-TUNING TECHNIQUE

A Novel Differential Microstrip Patch Antenna and Array at 79 GHz #Z. Tong 1, A. Stelzer 1,2, C. Wagner 2, R. Feger 2, E.

ELEC3242 Communications Engineering Laboratory Amplitude Modulation (AM)

Aalborg Universitet. Published in: th European Conference on Antennas and Propagation (EuCAP) Publication date: 2017

Gigabit Transmission in 60-GHz-Band Using Optical Frequency Up-Conversion by Semiconductor Optical Amplifier and Photodiode Configuration

Miniaturization Technology of RF Devices for Mobile Communication Systems

60 GHz RX. Waveguide Receiver Module. Features. Applications. Data Sheet V60RXWG3. VubIQ, Inc

CMOS RFIC Design for Direct Conversion Receivers. Zhaofeng ZHANG Supervisor: Dr. Jack Lau

Non resonant slots for wide band 1D scanning arrays

Real-Time Digital Down-Conversion with Equalization

An All CMOS, 2.4 GHz, Fully Adaptive, Scalable, Frequency Hopped Transceiver

HF Receivers, Part 2

FEATURES DESCRIPTION BENEFITS APPLICATIONS. Preliminary PT4501 Sub-1 GHz Wideband FSK Transceiver

Wavedancer A new ultra low power ISM band transceiver RFIC

FLEXIBLE RADIO FREQUENCY HARDWARE FOR A SOFTWARE DEFINABLE CHANNEL EMULATOR

DBR based passively mode-locked 1.5m semiconductor laser with 9 nm tuning range Moskalenko, V.; Williams, K.A.; Bente, E.A.J.M.

LOW COST PHASED ARRAY ANTENNA TRANSCEIVER FOR WPAN APPLICATIONS

Lecture 6. Angle Modulation and Demodulation

The Phased Array Feed Receiver System : Linearity, Cross coupling and Image Rejection

Communication Channels

Effects to develop a high-performance millimeter-wave radar with RF CMOS technology

Understanding Low Phase Noise Signals. Presented by: Riadh Said Agilent Technologies, Inc.

Modulation is the process of impressing a low-frequency information signal (baseband signal) onto a higher frequency carrier signal

Transcription:

Downloaded from orbit.dtu.dk on: Sep 01, 2018 An experimental vital signs detection radar using low-if heterodyne architecture and single-sideband transmission Jensen, Brian Sveistrup; Johansen, Tom Keinicke; Yan, Lei Published in: Proceedings of 2013 IEEE International Wireless Symposium (IWS) Link to article, DOI: 10.1109/IEEE-IWS.2013.6616752 Publication date: 2013 Link back to DTU Orbit Citation (APA): Jensen, B. S., Johansen, T. K., & Yan, L. (2013). An experimental vital signs detection radar using low-if heterodyne architecture and single-sideband transmission. In Proceedings of 2013 IEEE International Wireless Symposium (IWS) IEEE. DOI: 10.1109/IEEE-IWS.2013.6616752 General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

An Experimental Vital Signs Detection Radar using Low-IF Heterodyne Architecture and Single-Sideband Transmission Brian Sveistrup Jensen 1,2, Tom K. Johansen 1, Lei Yan 1 1 Technical University of Denmark, Kgs. Lyngby, DK-2800, Denmark 2 Thrane & Thrane, Kgs. Lyngby, DK-2800, Denmark Email: tkj@elektro.dtu.dk Abstract In this paper an experimental X-band radar system, called DTU-VISDAM, developed for the detection and monitoring of human vital signs is described. The DTU- VISDAM radar exploits a low intermediate frequency (IF) heterodyne RF front-end architecture and single-sideband (SSB) transmission for easier and more reliable extraction of the vital signs. The hardware implementation of the proposed low-if RF front-end architecture and associated IF circuitry is discussed. Furthermore, the signal processing and calibration steps necessary to extract the vital signs information measured on a human subject are described. Index Terms Human vital signs, low-if architecture, radar, single-sideband transmission. I. INTRODUCTION The measurement of human vital signs by wireless technology has been of great interest since the first sensors were demonstrated in the early 1970 s [1]. Essentially, these sensors are based upon microwave radar detection where the mechanically movement of the chest of the human subject results in a measurable change in the returned radar signal. By subsequent data processing it is possible to identify the heartbeat and respiration rates. Despite an extensive research effort in non-contact vital signs detection (VSD) radar within the past decade [2-3], these wireless sensors still lack widespread acceptance in the health care community. A major problem is that the faint return signal due to the physiological chest movement is difficult to separate from the much stronger interference signals caused by random body movements and unwanted reflections from static objects within the antenna beam. Furthermore, the received low-frequency baseband signal ranging from 0.1 to 3.3 Hz may be buried in 1/f-noise coming from the electronic components, in particular the amplifiers and mixers in the receiver chain. To overcome the limitation experienced with present VSD radars, which are mainly based on the direct conversion (homodyne) architecture, the low-if heterodyne architecture was recently proposed [4]. Although the hardware is slightly more complex, the low- IF heterodyne architecture reduces or completely eliminates the problems with 1/f-noise, DC offset errors, and I/Q channel mismatches. In [5], the authors showed x(t) Rx Antenna Tx Antenna RF Tx & Rx Unit Low noise amplifier Power Amplifier Baseband circuitry DSB mixer A Digital I-Q D demodulation IF amplifier A/D conversion Local oscillator IF locked SSB mixer IF signal Fig. 1. The low-if heterodyne VSD radar architecture. The human subject under test is also shown. theoretically that the low-if heterodyne architecture suffers from null-point detection distances similar to that found in single chancel direct conversion VSD radars [3]. To avoid these null-point detection distances the use of single-sideband transmission was proposed and an instrument based VSD radar was built to demonstrate the concept. Recently, a complete experimental X-band radar system for vital signs detection and monitoring, called DTU- VISDAM, has been implemented at the Technical University of Denmark (DTU). The aim of this radar is to demonstrate the benefits of the proposed low-if heterodyne architecture with single-sideband transmission for VSD radars. To the best of the author s knowledge the DTU-VISDAM radar presents the first non-instrument based VSD radar based upon the low-if heterodyne architecture with single-sideband transmission. II. LOW-IF HETERODYNE ARCHITECTURE A simplified block diagram for a VSD radar using a low-if heterodyne architecture is shown in fig. 1. The shown architecture use an up-converter sidestep configuration with a mixer and an IF generator. A downconversion sidestep configuration is also possible. Going through the signal theory for these two configurations reveals that they are essentially identical in operation. Common to both configurations is the locking (coherency) between the sampling circuit and the IF generation circuit. This is important in order to suppress the phase noise generated in the IF generator circuit.

Fig. 3. Front and back view of the DTU-VISDAM radar assembly. Fig. 2. Block diagram of the DTU-VISDAM radar. One of the drawbacks of the architecture in Fig. 1 is an increase of spectral components in the sidestep signal, owing to additional mixing products. To this end, one of the most important design aspects is that an SSB signal is needed for transmission (or down-conversion). This requires that the sidestep mixer is configured as a slightly more complicated circuit, i.e. as an image-reject mixer (IRM). In [5], the authors presented a detailed analysis highlighting the difference between using an SSB sidestep mixer rather than the simpler double-sideband (DSB) sidestep mixer. To emphasize the importance of this choice, the IF signals obtained by using either techniques are given here in compact form as S DSB 4π 4π ( t) cos x( t) + d0 cos λrf λ RF for the DSB case and S SSB ( ω t) = (1) 4π 4π ( t) cos IFt + x( t) + d λrf λrf = 0 ω (2) for the SSB case where IF =2 f IF is the IF angular frequency, x(t) represents the chest wall movement due to heart- and respiration activity, d 0 is the nominal distance to the target, and RF is the resultant wavelength associated with the up-converted RF signal. Similar wavelength RF is assumed for both the upper and lower sidebands due to the low-if frequency. It can be seen from (1) that the IF signal obtained using a DSB sidestep mixer is a sine wave at the IF frequency with its envelope modulated by the chest wall movement. Therefore null-points and optimumpoints will be present and determined by the nominal distance, d o, to the subject under test. In the case of an IF Fig. 4. Photograph of DTU-VISDAM s front-end electronics. SSB sidestep mixer, (2) shows that the modulation is placed onto the phase of the IF signal meaning that the envelope is no longer modulated by the variation in distance, i.e. null-detection points have been eliminated. III. THE DTU-VISDAM RADAR SYSTEM A block diagram of the DTU-VISDAM radar is shown in Fig. 2. The top part consists of an RF transceiver and two IF parts for the transmitter and receiver, respectively, while the bottom part consists of the control unit and the power supply unit. The IF parts handles the IF signal amplification and filtering in the receive path as well as IF signal split in the transmission path. The IF signal split generate signals with 90degrees phase difference to be fed into a Hittite I/Q mixer (model: HMC5271LC4) which effectively operates as an image reject mixer (IRM). This generates the single-sideband signal needed for transmission. The amplitude and phase of the split IF can be adjusted independently for best image suppression of the transmitted signal. The antennas are implemented as 2x2 microstrip patch antenna arrays with a measured gain of approximately 11.1 dbi and 58degrees beamwidth. A key component in the DTU-VISDAM radar is the Hittite PLL with integrated VCO (model: HMC769LP6CE) which serves as the common RF oscillator with a frequency set in the range from 9.05 to 10.15 GHz. The mixer LO inputs are provided through a set of medium

power amplifiers from Hittite (model: HMC451LP3). A combination of a resistive attenuator and a resistive splitter provides an option for tailoring the LO input power to the mixers. With this setup it is possible to provide up to 16 dbm of LO power to the mixers. The receive path of the RF front-end consists of two cascaded low-noise amplifiers (LNA s) from Hittite (model: HMC564LC4) followed by yet another Hittite I/Q mixer (model: HMC5271LC4). Only a single IF output (I or Q channel) is selected from the receive mixer for further processing. This is determined by a Vishay SPDT switch (model: DG403). The IF frequency is chosen to be 1 khz as this is easy to both generate and sample digitally. Coherent operation is ensured by using the same clock source for both IF signal generation and sampling. Fig 3 shows the front and back views of the assembled DTU-VISDAM radar. The front view provides a custom tailored user interface for selection of frequency, IF channel selection (I or Q out of the receive mixer), and signal amplification. A photograph of the front-end electronics is shown in Fig 4. The RF design comprises a single PCB containing all sub circuits. To increase the isolation between them the entire RF part is subdivided into 20x20x15 mm (width, length, height) compartments such that the cavity resonance frequency is located well above the radar operation frequency. The performance of the complete radar unit is summarized in table I. TABLE I. Performance parameters of the VISDAM radar unit Performance Units RF Bandwidth (RF radar frontend) 9.05-10.15 GHz RF Bandwidth (inclusive 9.235-9.455 GHz antennas) Image Reject Ratio (output) >45 db Transmit Power -40 to 0 dbm Antenna Gain (both Tx and Rx) 11.1 dbi Antenna Cross Talk (Tx-to-Rx) <-65 db IF Center Frequency 1.0 khz IF Bandwidth 3.0 khz Tx-Rx Isolation (RF front-end) 75 db Supply Voltage 15.0 V Power Consumption 5.25 W IV. EXPERIMENTAL RESULTS A. Digital I/Q Demodulation and Calibration The output signal of the DTU-VISDAM radar is a timedomain sinusoidal signal at 1 khz with a nearly constant envelope due to the single-sideband transmission and with a phase modulated by the heartbeat and respiration activities from the subject under test. The extraction of the vital signs information from the sampled low-if signal is Fig. 5. General procedure for amplitude and phase extraction through digital I/Q demodulation and calibration. based on a digital I/Q demodulation technique. The general procedure for extraction of the amplitude and phase information is outlined in Fig. 5. In general, two measurements are used, i.e. a vital signs measurement and a calibration measurement, both of which include a reference signal for phase alignment between measurements taken at different times. The phase reference is simply a loop-back of the outputted IF signal. The calibration is performed using a microwave absorber in front of the radar to measure the cross-talk. The first step in the demodulation process is to downconvert the input signal to an I/Q complex baseband signal. Mathematically this first step can be written as, I(n) j2πt(n)f + j Q(n) = S(n) e IF (3) where S(n) represents the sampled IF data and t(n) is the time vector. Once the I/Q baseband signal is obtained, a low pass filter (LPF) of the FIR type is applied to the data. After low pass filtering, the complex signals from both the calibration and VSD signal, are phase corrected using the reference phase acquired during each measurements. This step ensures that the calibration data can be properly referenced to the VSD signal. As the calibration data are not modulated they resemble ideally a single point DC offset in the I/Q plane. The mean value of the calibrated data is calculated to remove noise and subtracted from the VSD data. The calibrated VSD data is still not sufficient for proper detection as the influence from clutter signals is too high. Therefore, the calibrated signal is run through a best circle fitting algorithm. It fits the data to a circle with origin near (0,0) by running through a number of DC offset points around the calibrated data and finding the point at which the standard deviation of the amplitude signal is lowest. Figure 6 shows an I/Q plot after

Fig. 6. I/Q plot after calibration and curve-fitting. calibration and curve fitting. The signal amplitude and phase can now be extracted based arctangent demodulation performed on the corrected I/Q data [6]. B. Analysis of Extracted Vital Signs Signals The analysis of the extracted vital signs signals begins with filtering to separate the signals containing respiration or heartbeat signals. The heartbeat signal is selected as the output from a high pass filter with a cut-off frequency around 0.7 Hz while the respiration signal is taken as the output signal from a low-pass filter with cut-off frequency of 0.6 Hz. Having isolated the heartbeat signal, a moving window is applied for tracking of the heart rate. For the extraction of the heart rate, two different methods could be applied. The first method is based on the search of the highest spectral peak in the FFT spectrum. The second method calculates the auto-correlation of the time signal and finds the periodicity in the resulting signal. As the signals are not truly sinusoidal in nature, the latter analysis technique is applied. The analysis steps for evaluation and tracking of the respiration rate is identical to those described above. Fig. 7 shows the extracted respiration and heartbeat signals along with the heartbeat reference signal obtained with a finger pressure transducer. The extracted respiration rate is approximately 10 breaths/minute and the heart rate is around 60 beats/minute. The detected heart rate is tracked within 10% of the reference at all times. VII. CONCLUSION In this paper an experimental X-band radar for vital signs detection and monitoring was described. The VSD radar uses a low-if architecture with single-sideband transmission. The operation of the VSD radar together with the implemented signal processing methods was verified experimentally on a human subject. Fig. 7. Extracted respiration and heartbeat signals. Bottom plot shows the heartbeat reference signal obtained with a finger pressure transducer. ACKNOWLEDGEMENT The authors wish to acknowledge the Danish fond Radiopartsfonden for financial support. REFERENCES [1] J. C. Lin, Microwave Movement Sensing of Physiological and Volume Change: A Review, Bioelectromagnetics, vol. 13, issue 6, pp. 557-565, 1992. [2] A. D. Droitcour et al., Range Correlation and I/Q Performance Benefits in Single-Chip Silicon Doppler Radars for Noncontact Cardiopulmonary Monitoring, IEEE Trans. Microwave Theory and Tech., vol. 52, no. 3, pp. 838-848, March 2004. [3] Y. Xiao et al., Frequency-Tuning Technique for Remote Detection of Heartbeat and Respiration Using Low-Power Double-Sideband Transmission in the Ka-band, IEEE Trans. Microwave Theory and Tech., vol. 54, no. 5, pp. 2023-2032, May 2006. [4] C. Gu et. al, Instrument-Based Noncontact Doppler Radar Vital Sign Detection System Using Heterodyne Digital Quadrature Demodulation Architecture, IEEE Trans. Inst. And Meas.,vol. 59, no. 6, pp. 1580-1587, June 2010. [5] B. S. Jensen et. al, Vital Signs Detection Radar using Low Intermediate-Frequency Architecture and Single-Sideband Transmission, European Microwave Conf., Nov. 2012. [6] B.-K. Park, O. B.-Lubecke, and V. Lubecke, Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems, IEEE Trans Microwave Theory and Tech.,vol 55, no. 5, May 2007.