Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright display Make reading from long distance and low light location easier Multi-inputs & Multi-ranges User selectable Thermocouple, RTD, V, mv and Current inputs A 25Ω resistor is required across the input terminal for 4-2mA DC Inverse scaling possible With voltage and current input signals, normal and inverse scaling is possible. Additionally, normal and inverse scaling is possible for the analog output signals. Dust and splash proof front panel Equivalent to IP66 Wide range of optional features Alarms, analog output signals and communication interface (RS232C or RS485) available A six-point selector switch, (the series), is available for combined use.
SPECIFICATIONS Series SD16 Display Digital display Action display Display accuracy Display accuracy range Display resolution Measured value display range Display update cycle Setting Setting Setting range Input Type of input Thermocouple External resistance Input impedance Burnout Cold junction temperature compensation accuracy R.T.D. Amperage Lead wire tolerable resistance Voltage (mv) Voltage (V) Input impedance Current Input impedance Input scaling function Scaling range Span Position of decimal point Sampling cycle PV bias PV filter Isolation Alarm output (option) Number of alarm points Alarm type Alarm setting range Alarm action Alarm sensitivity Alarm output / rating Alarm output update cycle : Process value (PV) 7 segment Red LED 4 digits (H: 2mm) :1 point of parameter display (SET) by green LED :1 point of communication display (COM) by green LED :2 points of alarm (AL1, AL2) by red LED : ±(.3% FS+1 digit) within measuring range : Excluding cold junction temperature compensation accuracy in the case of thermocouple input :±5%FS for temperature below 4 C of thermocouple B : When the thermocouple [T, U] indication value is ~1 C,.5%FS and when it is below -1 C, 1%FS : 23 C±5 C (18~28 C) : Depends on measuring range (.1,.1,.1, 1) : -1~11% of measuring range (Accuracy guaranteed for value is within measuring range only) : For R.T.D. input of -2~6 C: 21~68 C : For thermocouple [K] input of -199.9~8 C: -273.1~9. C :.5~5. seconds (.5 steps) When.5 second or more is set, there may occur a difference among the displayed value, the analog output and the communication data. : By four (4) front key switches : Same as measuring range : Three-type multiple input of Thermocouple, R.T.D., Voltage (mv, V) : B, R, S, K, E, J, T, N, {U, L (DIN 4371)}, WRe5-26 Refer to measuring range code table : 1Ω max. : 5KΩ max. : Standard feature (Up-scale) :±1 C (18~28 C range) : ±2 C (5~18 C, 28~45 C range) (±5 C to the negative side of measuring range in case of T and U input) :JIS Pt1Ω 3-wire type : Approx..25mA :5Ω max. / wire (3 lead wire should have same resistance) When the resistance value of each wire is same ~5Ω:.5 C, 5~1Ω:.2 C, 1~2Ω:.6 C, 2~3Ω: 1.4 C max. : ~1mV DC : ~5V, 1~5V, ~1V DC : 5KΩ min. : 4~2mA DC : 25Ω [A shunt resistor (option) needs to be connected to the terminal] : Scaling possible for voltage (mv, V) or current (ma) input and inverse scaling possible. : -1999~9999 unit : 1~5 unit : None,.,.,. :.5 seconds :±2 unit : ~1 seconds ( = without filter) : Between input and analog output :2 (AL1 and AL2) for both normal open and common : Selectable from combinations of the following 4 types : High limit absolute value without inhibit action : High limit absolute value with inhibit action : Lower limit absolute value without inhibit action : Lower limit absolute value with inhibit action :Within measuring range or within full scaling range : ON-OFF action : 1~999 unit Within measuring range : Contact 1a (common) / 24V, AC1.5A (resistive load) :.5 seconds
SPECIFICATIONS Series SD16 Analog output (option) Analog output type Output resolution Output accuracy Output scaling Output update cycle Communication (option) Communication type Communication system Communication speed Data bit length Communication address Multi-drop connection Communication delay Communication code Others Data storage Ambient conditions for use Temperature and Humidity Height Installation category Degree of pollution Power supply voltage Power consumption Applicable standard Safety EMC Dust proof/drip proof Insulation resistance Dielectric strength Case material External dimensions Mounting Panel thickness Panel cutout Weight : ~1mV DC (output resistance: 1Ω) : ~1V DC (load current: 1mA max.) : 4~2mA DC (load resistance: 3Ω max.) : Approx..3% (1/3) :±(.3%FS + 1 digit) of display value :Within measuring range (inverse scaling possible) :.5 seconds : RS-232C, RS-485 : Half duplex start-stop synchronized system : 12, 24, 48, 96, 192 bps :7 bit even parity 1 stop bit 8 bit non parity 1 stop bit : 1~255 : 31 max. (with RS-485) : ~5. milli-seconds : ASCII code : By non volatile memory (EEPROM) : -1~5 C/9%R max. (on condition that there is no dew condition) : 2m above sea level or lower : Category II : Degree 2 : 1~24V AC±1%, 5/6Hz 24V AC/DC ±1% (option) : 11VA (AC) max., 7W (DC) max. : IEC 11-1 and EN611-1 : EN61326 (EMC testing Display accuracy: +5% FS) : IP66 (Complies with the IEC 529-IP66) : Between input/output terminal and power supply terminal: 5V DC 2MΩ minimum : Between input/output terminal and protective conductor terminal 5V DC 2MΩ minimum :1 min. at 23V AC between input/output terminal and power supply terminal :1 min. at 15V AC between power supply terminal and protective conductor terminal : PPO resin molding (equivalent to UL94V-1) : H48 x W96 x D11 mm : Push-in panel (one-touch mount) : 1.~4. mm : H45 x W92 mm : Approx. 25g
SPECIFICATIONS Series Selector series No. of switching points No. of switching circuits Switching operation method Applicable signal contact rating Contact method Voltage Current Contact resistance Operating ambient temperature range Operating ambient humidity range Material Color External dimensions Panel cutout Mounting Panel thickness Weight :6 :2 : Push button switching : DC voltage, current (R.T.D.is not applicable) : Contact slide : 3V DC max. : 1mA DC max. : 3m Ω max. : -1~5 C : 9% RH max. : PPO resin : Case : Munsell No. N-1 or compatible Front Panel: Munsell No. N-1 or compatible : H48 x W96 x D118 (panel depth: 1) mm : H45 x W92 mm : Push-in panel (one-touch mount) : 1.~4. mm : Approx. 25g APPLICATION EXAMPLE 1. Selection of T. C. Switching 2. Selection of Voltage Switching T. C. Compensating Lead Wire Compensating Lead Wire T. C. Converter Copper Lead Wire Copper Lead Wire Indicator Voltage Indicator Recorder R. T. D. Converter Recorder 3. Selection of Analog Output (Voltage) 4. Installation Example With SD16 Control Signal Controller Analog Output SD16 Indicator SD16 Controller Analog Output K R 1 6 Control Signal Recorder
ORDERING INFORMATION Series SD16 ITEM CODE SPECIFICATIONS 1 SERIES SD16- Digital Indicator DIN Size 48 96 mm Current (4~2mA DC) 4 A shunt resistor (option) needs to be connected to the terminal *Thermocouple B, R, S, K, E, J, T, N, 2 INPUT {U, L (DIN 4371)} 8 Multi input *R.T.D. Pt1Ω *Voltage (mv, V) ~1mV DC, ~5V DC, ~1V DC, 1~5V DC 9-1~24V AC±1% (5/6Hz) 3 POWER SUPPLY 8-24V AC ±1% (5/6Hz) / 24V DC ±1% None 4 ALARM OUTPUT (OPTION) Individual setting, individual output 2 points (1c contact) 1 Contact capacity: 25V AC 1.5A / resistive load None 3 ~1mV DC Output resistance: 1Ω 5 ANALOG OUTPUT (OPTION) 4 4~2mA DC Load resistance: 3Ω max. 6 ~1V DC Load resistance: 1mA max. None 6 COMMUNICATION FUNCTION (OPTION) 5 RS-485 7 RS-232C Without 7 REMARKS 9 With (Please consult before ordering) Value set at K ~12C when shipped MEASURING RANGE CODES INPUT TYPE CODE RANGE (ºC) RANGE (ºF) B 1 ~ 18 ~ 33 R 2 ~ 17 ~ 31 S 3 ~ 17 ~ 31 K 4-199.9 ~ 8. -3 ~ 15 K 5 ~ 12 ~ 22 THERMOCOUPLE E 6 ~ 7 ~ 13 J 7 ~ 6 ~ 11 T 8-199.9 ~ 3. -3 ~ 6 N 9 ~ 13 ~ 23 1 U 1-199.9 ~ 3. -3 ~ 6 1 L 11 ~ 6 ~ 11 2 WRe5-26 12 ~ 23 42 R.T.D. Pt1Ω 31-2 ~ 6 3-3 ~ 11 Pt1Ω 32-1. ~ 1. -15. ~ 2. ~1mV 71 Thermocouple B, R, S, K, E, J, T, N: JIS/ANSI/IEC 1 Thermocouple U, L: DIN 4371 VOLTAGE ~ 5V 81 1~ 5V 82 ~1V 83 CURRENT 4~2mA 95 3: -2. ~ 6. ºC Initial value:.~1. Scaling setting range: -1999~9999 Span: 1~5 counts range available. Please specify when ordering. 2 Thermocouple WRe5-26: Made of Hoskins ORDERING INFORMATION Series ITEM CODE SPECIFICATIONS 1 SERIES - Push button six-point selector Without 2 REMARKS 9 With (Please consult before ordering)
EXTERNAL DIMENSIONS & TERMINAL ARRANGEMENT Series SD16 & SD16 External Dimensions Terminal Arrangement 96 11 111 1 AL1 AL2 RS-232C SG RS-485 SG Communication Analog output SD RD + - + - AL1 11 12 13 14 15 16 17 18 19 2 AL2 SET COM SD16 ENT 48 44.6X91.6 + ma (25Ω register attached externally) V - R.T.D. A B B 92 +.8 Panel Cutout 1-24V AC + mv - + T.C. - L 5/6Hz N 1 2 3 4 5 6 7 8 9 1 45 +.6 6min. 11min. (Unit : mm) (Unit mm) 1 2 External Dimensions 96 18 3 4 5 6 48 118 1 44.6X91.6 6 + - 11 12 Terminal Arrangement OUTPUT + - + - + - + - 1 2 3 4 INPUT + 13 14 15 16 17 18 19 2 1 2 3 4 5 6 7 8 9 1 - + - 5 45 +.6 Panel Cutout 11min. In case installed with SD16 Panel Cutout 92 +.8 92 +.8 93 +1 (Unit : mm) (Unit : mm) Warning The SD16 & series is designed for the control of temperature, humidity and other physical values of general industrial equipment. (It is not to be used for any purpose which regulates the prevention of serious effects on human life or safety.) Caution If the possibility of loss or damage to your system or property as a result of failure of any part of the process exists, proper safety measures must be made before the instrument is put into use so as to prevent the occurrence of trouble. ISO 91 (The contents of this brochure are subject to change without notice.) Temperature and Humidity Control Specialists Head Office: 2-3-1 Kitamachi, Nerima-Ku, Tokyo 179-81 Japan Phone: +81-3-3931-7891 Fax: +81-3-3931-389 E-MAIL: exp-dept@shimaden.co.jp URL: http://www.shimaden.co.jp ESD16 & 13