Ø 1250 * 688 mm 93 kg ± 105m

Similar documents
GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Ø560*336mm 4.25 kg 2100 ± 105m

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Single-Armored Cables, Fibers

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

Outdoor, Fig 8 Armored, Multi Tube

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Outdoor, CCTV or CCTV, Fig 8 Armored.

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

Optical Systems Contents

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

Fibre Optic Indoor/Outdoor Cable

features and benefits

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

Fiber Optic Outside Plant Cables (4-144 Fibers)

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Integrating Global Communications...

SPECIFICATION. Optical Fiber Cable

Datasheet Outside Plant Cable

Exhibit A Construction Project Manual and Drawings

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Outside Plant All Dielectric

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

Type QG-G50-2C- M-BU

Standard Monotube SAFE

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables

u n a B Optical Cables UNIFLEX CABLES LTD.

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

Industrial Automation

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

COPPER + LWL RAW CABLES

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

Electric cables. Cranes

Z EE E E Z E Z Z Z Z Z

FTTH Fiber Optical Cable

Information technology. Generic cabling systems, General requirements

Data, Network and Bus Technology

14 AWG 2 AWG: 600 Volt

Y O U R W A Y ENGINEERING PRODUCTS. adritec.com

Medium Voltage Power Cables

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

ABOUT US ABOUT US 1 CRANE CABLES

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Faster. Easier. Better.

CUSTOM DESIGN COAXIAL CABLES BY SICAB

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

FiberHome Fiber Products

Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

kv: medium voltage reeling cable with fibreoptics

ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND. designed to be better.

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR FlexNAP DISTRIBUTION SYSTEMS: DISTRIBUTION TRUNK, TAP, AND TETHER. July 2018.

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

CommunicationCables FIBER OPTICS OPGW FTTH

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

UNIRAIL D RS485 and BUS cables

OFS AllWave non-dispersion shifted single-mode optical fiber

Nufern 980 nm Select Cut-Off Single-Mode Fiber

Category 6 UTP EuroClass C ca Cables

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

Connection technology for wireless communication systems

Category 6 A F/FTP Euroclass C ca Cables

Optical Characteristics of a Reduced Bending-Loss Fiber with a Bending Radius of 5 mm

X-ECT MX Electrical Cable Tie, X-EKS MX and X-EMTSC Conduit Clip Fastener

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

OPTICAL FIBER CABLE. August 2017, New Delhi. CM/L-No

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

Optical Ground Wires (OPGW)

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Jumper cable. Feeder cable + connector. Cable clamp. Grounding kit

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

Fiber Optic Principles. Oct-09 1

MULTIMEDIA CABLE H6091ZHB

Why Using Fiber for transmission

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

Application of Ultra-Low Bending Loss Fiber PureAccess-R5 to Optical Wiring in FTTx Access Networks

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

Transcription:

GCDE Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection 05-05-5 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 84 96 6.5/5-OM GCDE84 GCDE96 50/5-OM BI GCDE84 GCDE96 50/5-OM3 BI GCDED84 GCDED96 50/5-OM4 BI GCDEE84 GCDEE96 ITU G.655 C&D GCDE784 GCDE796 ITU G.65D & G.657A BI GCDE884 GCDE896 ITU G.657A BI GCDEF84 GCDEF96 ITU G.657B3 BI GCDEI84 GCDEI96 Std. plywood reel (non-returnable) Std. delivery length Ø 50 * 688 mm 93 kg 00 ± 05m Applications For outdoor and indoor use in structured (data) wiring systems such as (campus backbone). For outdoor and indoor use in networks for telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm). Features & Benefits Installation friendly dry interstices between the loose tubes. Predicted lifetime > 30 years. High mechanical and full rodent protection provided by corrugated steel tape (CST) armor. The cable has been designed to meet the requirements of LUL -085 standard.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794). Dielectric central element of glass reinforced plastic (GRP), also as protection against kinks, surrounded by swelling yarns.. Jelly filled (non-dripping and silicon-free) loose tubes with primary coated optical fibres (Ø 50 ± 5 µm). Individually colour coded optical fibres: red green blue yellow violet pink orange black grey brown white turquoise. 3. The loose tubes are stranded around the central element, if necessary with fillers (PE-natural), surrounded by swelling tape. Colour coding of the loose tubes:. red. green rest white. 4. Swellable (for the longitudinal watertightness) aramid yarns as strength members. 5. FRNC/LSNH inner jacket. 6. Corrugated Steel Tape Armoring (CST): longitudinally applied steel tape (0.55 mm). 7. UV resistant FRNC/LSNH outer jacket. Identification: BELDEN OFC cable type number x fibre type + date-, meter- and marking. Mechanical Data No. of fibres Max. 96 Cable core 8 tubes Ø Central element (mm) 3.0/4.3 Ø Loose tube (mm).5 Ø nom./max. (mm) 7.4 / 7.7 Energy of flame (kj/m) 4700 Weight (kg/km) 340

Optical Characteristics Characteristics Single-Mode Matched-Cladded optical fibres according to ITU. Mode-Field /Cladding Diameter (um) Attenuation B typical/ max. (db/km) Dispersion (ps/(nm-km) PMD (ps/km) Cable Cut-off 7 G.655 C&D 8.4 ± 0.6 5 ± 0.7 0. / 0. 0. / 0.4 4.5 7.9 < 0.04 A 60 8 G.65D & G.657A BI OS 9. ± 0.4 5 ± 0.7 30 3 / 4 0.8 / 0.9 0.0 / 0.4 3. 7 0.06 60 F G.657A BI 8.9 ± 0.4 4.8 ± 30 4 / 5 0.9 / 0. 0.0 / 0.4 3.5 8 0. 60 I G.657B3 BI 8.8 ± 0.4 5 ± 0.4 30 4 / 5 0.9 / 0. 0.0 / 3.5 8 0.06 60 Note A- Link design value Note B- Due to cabling the optical attenuation values can increase with max. 0.05 db/km Characteristics Multi-Mode Graded-Index optical fibres according to IEC 60793 Fibre- Type Core/ Cladding Diameter (um) Attenuation C typical/ max. (db/km) Bandwidth (MHzkm) Ethernet Performance (m) GBE 0 GBE Num. Apert. (μm) 6.5/5 OM 50/5 OM BI 6.5 ±.5 5 ± 50 ±.5 5 ±.7 / 3.0 0.7 / 0.8.3 /.5 / 0.6 00 600 0 600 600 33 83 0.75 ± 0.05 0.0 ± 0.05 D 50/5 OM3 BI 50 ±.5 5 ±.3 /.5 / 0.6 000 0.0 ± 0.05 E 50/5 OM4 BI 50 ±.5 5 ±.3 /.5 / 0.6 3500 00 0.0 ± 0.05 Note C- Due to cabling the optical attenuation values can increase with max. 0.4 db/km 3

Macro Bending Performance Fibers Maximum attenuation increase for Bend Insensitive Single Mode fibers in db depending on turns and radius. 7 G.655 C & D 00 30 mm 0.05 0.05 0 5 mm 6 mm 0 mm 7.5 mm ) 5 mm 8 G.65D & G.657A BI OS 0.5.0 0.75.5 F G.657A BI 0. 0. 0..0 I G.657B3 BI 0. 0.08 0.5 0.5 0.45 Maximum attenuation increase for Bend Insensitive Multi Mode fibers in db depending on turns and radius. 6.5/5 OM 00 37.5 mm 5 mm ) 7.5 mm 50/5 OM BI 0. 0. D 50/5 OM3 BI 0. 0. E 50/5 OM4 BI 0. 0. 4

Mechanical, Physical and/or Environmental Characteristics Description: Tested according to: Requirement: According to Family specification: Storage Temperature Range IEC 60794---F -30 to +70 C IEC 60794-3-0 Installation Temperature Range -5 to +50 C Operating Temperature Range -30 to +70 C Bending Tube (Installation and Operation) > 5 mm Cable Core Water Blocking IEC 60794---F5 Pass Cable Min. Bend Operation (Long Term) IEC 60794---E 0 x Cable Diam. IEC 60794-3-0 Cable Min. Bend Installation (Short Term) IEC 60794---E6 0 x Cable Diam. Cable Max. Tensile Strength Operation (Long Term) IEC 60794---E 950 N IEC 60794-3-0 Cable Max. Tensile Strength Installation (Short Term) Cable Max. Crush Resistance Operation (Long Term) Cable Max. Crush Resistance Installation (Short Term) IEC 60794---E3 900 N kn/m kn/m IEC 60794-3-0 Safety Testing standard Description / Value Reaction to fire IEC 6033- IEC 6033-3- Toxicity NF X 70-00- Halogen acid gas content IEC 60754- Zero Degree of acidity of gases IEC 60754- Min. 4.3 ph IEC 60754- Max. 0 μs/mm Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes by means of compressed air or pulling wire, certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > mm must be prevented. The jelly filling inside the tubes can be removed using a tissue soaked in turpentine. It is advisable to cap the cable-ends during storage. Options Cables for outdoor use only. Non-standard cable constructions, colours, details and/or additional information regarding specifications are available on request. 5