Programmable AC Current Transducer MT418

Similar documents
Programmable AC Voltage Transducer MT416

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Measuring transducers

Measuring centers MC7x0 series Multifunction Meter MC740

MT 560/UMT TRANSDUCER & ANALYZER

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

Theta 20A / 20V. Technical Data Sheet. Special Features

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

ELECTRICAL NETWORK RECORDER - MC 750 ELECTRICAL NETWORK ANALYZER -MC 760 ENERGY METER - MC 720 POWER METER - MC 710 MULTIFUNCTION METER - MC 740

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Theta Hz. Technical Data Sheet. Special Features

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Technical Data Sheet. x1000. kwh R Y B

SINEAX U 553 Transducer for AC Voltage

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

UMG 103-CBM. Universal measurement device for DIN rails

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

ULTRA RAPID POWER QUALITY ANALYZER

Custom "Compact" range with display CD20 Custom Part number

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

02/11/2015

02/11/2015

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

02/11/2015

02/11/2015

B850 Boiler House Energy Monitor

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

B850 Boiler House Energy Monitor

VariTrans P D1 TRMS

SINEAX I 552 Transducer for AC current

Energy Management Energy Meter Type EM340

Synchronisation meters for manual or semiautomatic synchronisation Synchronization Meters SQ0114/SQ0104 Synchronization Meters SQ0214/SQ0204

High precision measurement system for current and voltage IHC-A/B-RM01/03

Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Product Guide. Transducers

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Side view View from below Rear view

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

02/11/2015

General Specifications

Type CP-S, CP-C & CP-A Switch mode

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Data Sheet. RISH Master Record %THD

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

DATA SHEET Selectable AC transducer TAS-311DG

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Energy Management Energy Meter Type EM110

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Energy Management Energy Analyzer Type EM112

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Energy Management Energy Analyzer Type EM111

SINEAX V 604s Programmable multifunctional transmitter

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Universal measuring transducer

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Analog Universal Module HART for Zone 2 Series 9468/33

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Cewe Digital Programmable Transducer User Manual. Ver. 1.2

Energy Management Energy Meter Type EM110

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Integra 1560 and 1580 Digital Transducer Systems

Mars-Energo. Volt/mA Calibrator CALMAR-S. User s manual Edition 3.1

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

High Performance Process & Temperature Controllers

Environmental. Electrical Specifications at 25 O C TYPE HL. Output Constant Current. Output Voltage Range

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

NEW! Transient Data Acquisition. Stand alone. Compact. Powerful.

Power Meter Series PM3200 Functions and characteristics

SINEAX TV809, 1 channel Programmable Isolating Amplifier

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

LC35/2-DA-iC. 35 W Dimmable two channel intelligent Colour LED driver. 35 W V 0 / Hz. Functional Description. Mains Characteristics

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Transcription:

Programmable AC Current Transducer MT418 RMS AC current measurements Current auto range measurements up to 12 A Frequency measurement range 16 400 Hz AC or universal wide auiliary power supply range 24 300 Vdc, 40 276 Vac Accuracy class 0.5 (EN 60688) Serial (RS232 or RS485) communication Sophisticated analogue output; 2 voltage and 4 current ranges, non-linear characteristics Simple USB setting without auiliary power supply WWW.ISKRA MIS.SI Page 1

PROPERTIES Measurements of RMS current, frequency, THD I and MD Accuracy class 0.5 (EN 60688) Input frequency range: 50/60 Hz, 400 Hz RS 232/RS 485 communication up to 115,200 bit/s and USB 2.0 communication MODBUS communication protocol Universal power supply or transformer power supply Automatic range (ma. 12 A) Housing for DIN rail mounting User-friendly PC MiQen software DESCRIPTION MT418 is intended for measuring and monitoring singlephase electrical power network. Current input is electrically isolated from the system by means of current transformer. It measures RMS current value by means of fast sampling of current signals, which makes instruments suitable for acquisition of transient events. A built-in microcontroller calculates measurands (current, frequency, THD U, MD) from the measured signals. Measurands (I, f) can be then converted into load independent DC current or voltage which is proportional to the RMS measured value for the purpose of regulation of analogue and/or digital devices. COMPLIANCE WITH STANDARDS: Standard EN 61010-1:2001 60688:1995/A2:2001 61326-1:2006 60529:1997/A1:2000 60068-2-1/ -2/ -6/ -27/-30 UL 94 APPLICATION Description Safety requirements for electrical equipment for measurement, control and laboratory use Electrical measuring transducers for converting AC electrical variables into analogue and digital signals EMC requirements for electrical for measurements, control and laboratory use- Part 1:General requirements Degrees of protection provided by enclosures (IP code) Environmental testing (-1 Cold, -2 Dry heat, -30 Damp heat, -6 Vibration, -27 Shock) Tests for flammability of plastic materials for parts in devices and appliances The MT418 current transducer is used for a permanent monitoring of a single-phase current and frequency values. MT418 is delivered configured to default values. Subsequent customer configuration is possible with user friendly setting software MiQen. MT418 supports standard serial RS232/485 with speed up to 115200 bps. USB 2.0 can be used for a fast set-up or memory acquisition (after installation USB connection is not possible any more). Additional USB 2.0 interface can only be used for a fast setup without need for auiliary power supply. This interface is NOT galvanically isolated from analogue output and can be used ONLY unconnected to au. supply and measuring inputs. Page 2 WWW.ISKRA MIS.SI

TECHNICAL DATA MEASUREMENT INPUT Nominal frequency range 50/60, 400 Hz Current measurements: Nominal values 1, 5, 10 A Rated current (I N ) 5 A Ma. measured value (cont.) 12 A sinusoidal Ma. allowed value (thermal) 15 A cont. Ma. allowed value 20 I N ; 5 1s (acc. To EN 60688) Consumption I 2 0.01Ω COMMUNICATION MT418 has one galvanic separated communication port, which can be equipped with RS232 or RS485 or left open (to be specified with order). Different configurations are possible (to be specified with order): Configuration WO RS232 RS485 WARNING: COM USB RS232 + USB RS485 + USB Frequency measurement: Frequency measuring range (Only for frequency meas.) 16 400 Hz USB communication port is NOT galvanically isolated and can ONLY be used unconnected to au. supply AND measuring inputs. System: Current input can be connected either directly to low-voltage network or shall be connected to network via a corresponding current transformer (with standard 1 A or 5 A output). BASIC ACCURACY UNDER REFERENCE CONDITIONS Total accuracy (measurements and analogue output) according to EN 60688 Accuracy is presented as percentage of range of the measurand s nominal value, ecept when it is stated as an absolute value. Presented accuracy is valid only for a full output range. In case if used output range is less than full output range (zoom-characteristics) see INTRINSIC ERROR on page 5. Defined accuracy of analogue output is valid only after 45 minutes after power up, due to self-heating. USB connector is placed on the bottom of the MT418, behind removable cap. After installation it is not accessible any more. When connected, MT418 is powered by USB port. USB (1) : Connection type Connection terminals Ma. connection length Function Isolation Direct mini USB-B 3 m Transfer mode Protocol Transfer rate USB 2.0 (1) Settings and records acquisition, firmware upgrade None, directly coupled with analogue output Asynchronous MODBUS RTU After installation of instrument on DIN rail not accesible any more Measurand Accuracy (±% of range) Voltage rms 0.5 0.3 (1) Frequency (f) 10 mhz 2 mhz (1) THD(I) (0 400 %) 0.5 (1) On communication Serial communication: RS232 RS485 Connection type Direct Network Connection terminals screw terminals Settings, measurements and records Function acquisition, firmware upgrade Isolation Protection class II, 5.2 kv ACRMS 1 min Ma. connection 3 m 1000 m length Transfer mode Protocol Transfer rate Number of bus stations Asynchronous MODBUS RTU 2.4 kbaud to 115.2 kbaud / 32 WWW.ISKRA MIS.SI Page 3

ANALOGUE OUTPUT Analogue output is fully programmable and can be set to any of 6 hardware ranges, 4 current and 2 voltage, without opening an instrument. They all use the same output terminals. Programmable DC current output: Output range 0 100% 0 1 ma Range 1 0 5 ma Range 2 0... 10 ma Range 3 0... 20 ma Range 4 other ranges possible by MiQen software Ma. burden voltage Ma. eternal resistance Programmable DC voltage output: 10 V R Bma =10 V / I outn Output range values 0 100% 0 1 V Range 5 0 10 V Range 6 other ranges possible by MiQen software Ma. burden current Min. eternal resistance General: 20 ma R Bmin = U outn / 10 ma Ma. voltage on output 33 V (open circuit current output) Linearization Linear, Quadratic No. of break points 5 Output value limits 120% of nominal output Response time < 100 ms (measurement and analogue output) Response time of fast < 50 ms analogue output Residual ripple < 1 % p.p. Residual ripple of fast < 2 % p.p. analogue output The output may be either short or open-circuited. It is electrically isolated from all other circuits. All output range values can be altered subsequently (zoom scale) using the setting software, but a supplementary error results (see INTRINSIC ERROR). POWER SUPPLY Universal power supply: Nominal voltage AC range Nominal frequency range Nominal voltage DC range Consumption Power-on transient current 40 276 V 45 65 Hz 24 300 V < 5VA < 20 A; 1 ms SAFETY: Protection: protection class II Pollution degree 2 Installation category CAT III; 600 V meas. inputs Universal au. power supply CAT III; 300 V Transformer au. power supply CAT III; 600 V Acc. to EN 61010-1 Test voltages I input Output, U AUX, COM 5200 VAC rms Transformer au. power supply U AUX Output, COM 5200 VAC rms Universal au. power supply 3500 VAC rms Output COM 500 VAC rms Enclosure material PC/ABS Acc. to UL 94 V-0 Enclosure protection IP 20 MECHANICAL Dimensions W45 H75 D105 mm Mounting Rail mounting 35 15 mm acc. to EN 50022 Enclosure material PC/ABS Vibration withstand 7g, 3 100 Hz, 1 oct/min 10 cycles in each of three aes Shock withstand 300g, 8ms pulse 6 shocks in each of three aes Connection terminals 4.0 mm 2 solid wire 2.5 mm 2 stranded wire Flammability Acc. to UL 94 V-0 Weight Transformer au. power supply 340 g Universal au. power supply 170 g ENVIRONMENTAL CONDITIONS: Ambient temperature usage group III -10 0 45 55 C Acc. to EN 60688 Operating temperature -30 to +70 C Storage temperature -40 to +70 C Average annual humidity 93% r.h. Altitude 2000 m Transformer power supply: Nominal voltage AC Nominal frequency range Consumption 110V, 230V 45 65 Hz < 5VA Page 4 WWW.ISKRA MIS.SI

INTRINSIC-ERROR (FOR ANALOGUE OUTPUTS): For intrinsic-error for analogue output with bent or linear-zoom characteristic multiply accuracy class with correction factor (c). Correction factor c (the highest value applies): Linear characteristic y0 1 ye c = or c = 1 0 1 e MiQen - SETTING AND ACQUISITION SOFTWARE MiQen software is intended for supervision of MT418 on a PC. Network and the transducer setting, display of measured and stored values and analysis of stored data in the transducer are possible via the serial or USB communication. The information and stored measurements can be eported in standard Windows formats. Multilingual software functions on Windows 98, 2000, NT, XP, Vista, Windows 7 operating systems. Bent characteristic b 1 b b number of break point (1 to 5) c = y b b y b 1 e or c = b 1 ye 1 MiQuen setting and acquisition software MiQen software is intended for: - Setting all of the instruments parameters (online and offline) - Viewing current measured readings - Searching the net for devices - Virtual interactive instrument - Comprehensive help support Eamples of settings with linear and bent characteristic WWW.ISKRA MIS.SI Page 5

CONNECTION DIMENSIONAL DRAWING Dimensions for MT418. CONNECTION TABLE Function Connection Measuring input: AC voltage I 2/11 Analogue output: + 15 16 Auiliary power supply: + / AC 13 / AC 14 R / A 21 Communication: RS232/485 GND / C 22 T / B 23 Page 6 WWW.ISKRA MIS.SI

ORDERING Supplement: MiQen software When ordering an MT418, all required specifications should be stated in compliance with the ordering code. Additional information could be stated regarding functionality of analogue output. Default settings for analogue output provided that no ordering information is given will be: Input quantity Iin: 0 5 A Output quantity Iout: 0... 20 ma If different analogue output settings are required, a proper input quantity / output quantity pair for analogue output should be provided. EXAMPLE OF ORDERING: MT418 transducer with frequency range 50/60 Hz, RS485 communication, normal analogue output and an universal supply. Ordering code: MT418 1 2 1 1 GENERAL ORDERING CODE All specifications are obligatory ecept function of analogue output, which should be stated in a form of description. 1. Transducer type: MT418 1. Input frequency 1 50/60 Hz 2 400 Hz 2. Communication type 0 Without 1 RS232 2 RS485 3. Analogue output 1 Normal 2 Fast 3. Power supply 1 Universal switching power supply 2 230 V transformer power supply 3 110 V transformer power supply Printed in Slovenia Subject to change without notice Version 1.00 / Feb 2011 GB P 22.496.502