SM 1222 DIGITAL OUTPUT MODULE

Similar documents
SM 1223 DIGITAL INPUT/OUTPUT MODULE

SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

FM COUNTER MODULE

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

EXM INPUT/OUTPUT EXPANSION

SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

FM 355 CONTROLLER MODULE

CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

FM HIGH-SPEED BOOLEAN PROCESSOR

FM COUNTER MODULE

FM COUNTER MODULE

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

6ES7314-6BH04-0AB0. STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

CPU 314C-2 PTP. Function

General specifications and features

SIMATIC S7-300 Function modules

FM POSITIONING MODULE

Data sheet CPU 313SC (313-5BF13)

SIMATIC S5. ET 100U Distributed I/Os. Manual. EWA 4NEB a

Zentralbaugruppen CPU 222

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet VIPA CPU 314SC DPM (314-6CG23)

Data sheet CPU 013C (013-CCF0R00)

Product Information. Release 3 4 SIMATIC ET 200S. 4DI UC V High Feature Digital Electronic Module

Product type designation. General information. Supply voltage

The DO8332 module is equipped with eight outputs for 1-wire connections. The rated output current is 2 A.

General information. CiR - Configuration in RUN

General information. Supply voltage

This data sheet is only valid in association with the IL SYS INST UM E user manual.

QUINT-PS-24DC/24DC/10

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

Siemens AG ED CB00-0BA0 6ED HB00-0BA0 6ED MB00-0BA1 6ED FB00-0BA1 Supply voltages Rated value

7.2 DV1311.L08 and DV1311.L12


PHOENIX CONTACT - 03/2007

8V General information. 2 Order data 8V

OUTPUT 5/24 VDC PWM/PT 2 CHANNEL. 1 Description. GFK-2761 May 2012

General information. CiR - Configuration in RUN

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

8V General information. 2 Order data 8V

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Isolating Repeater Input Series 9163

Totalizing Counters mini-i

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) SIMATIC. ET 200SP Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Preface. Documentation guide 1

UniStream Uni-I/O Modules

SIMATIC. ET 200B Distributed I/O Station. Preface, Contents. System Overview. Technical Description. Mechanical and Electrical Installation

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module for Zone 2 Series 9470/33

CAB2 Schematic drawing CAB3 CAB4 CAB5. CAB6 Schematic drawing CAB7 Schematic drawing CAB8 Schematic drawing 03315

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Isolators A3/1.

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

s Climatix extension module 26 I/Os POL985.00/XXX

Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) SIMATIC. ET 200SP Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) Preface

QAC910. Meteo Sensor. Synco living

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Multi-Variable Analog Interface for Smart Transmitters Specifications

Product Data Sheet 3252J/2H3PU

CAN-IO Custom IO remote module

UniStream Uni-I/O Modules

SALES SERVICE +358 (0)

Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board)

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Digital Input Output Module for Zone 2 Series 9470/33

IB IL AO 1/U/SF. Function. INTERBUS Inline Terminal With One Analog Voltage Output. Data Sheet 5736CC01

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

PHOENIX CONTACT - 09/2009

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Order number 031-1BB BB BB BD30 Figure. SM 031, AI 2x12Bit I. Note - - Coming soon - Features. 2 inputs, Current 0(4)...

Overcurrent Protection / 7SJ45

Analog Universal Module HART for Zone 2 Series 9468/33

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Product Data Sheet RG160-28/18N/2TDPU-331

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

SIMATIC. ET 200S distributed I/O 2AI I 4WIRE HS analog electronic module (6ES7134-4GB62-0AB0) Preface. Properties 1. Parameters 2.

Analog input module. AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1) SIMATIC. ET 200SP Analog input module AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1)

QUINT-PS AC/24DC/40

0 2 1 â Ó. itemp HART TMT182. Technical Information

Smart Power Relay E I...

Analog Input Module. AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0) SIMATIC. S7-1500/ET 200MP Analog Input Module AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0)

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Analog signal converters CC-E I/I

MINI-PS AC/2X15DC/1

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Product Data Sheet 3254 J/2H3P

Transcription:

SM 1222 DIGITAL OUTPUT MODULE Overview Digital outputs as supplement to the integral I/O of the CPUs For flexible adaptation of the controller to the relevant task For subsequent expansion of the system with additional outputs Application Digital output modules permit the output of digital signals from the controller to the process. This provides users with the following advantages: Optimum adaptation: With signal modules which can be mixed as desired, users can adapt their controllers exactly to the relevant task. This avoids superfluous investments. Modules with 8, 16, and 32 input/output channels are available. Flexibility: If the task is expanded subsequently, the controller can be upgraded. Updating of the user program is extremely simple. Function The SM 1222 digital output signal modules convert the internal signal level of the SIMATIC S7-1200 into the external signal level required by the process. Technical specifications Page 793 Mar 2008 Siemens ITS

Supply voltage permissible range, lower limit (DC) permissible range, upper limit (DC) Input current from backplane bus 5 V DC, max. Digital inputs from load voltage L+ 6ES7 222-6ES7 222-1BF30-0XB0 1BH30-0XB0 SM 1222 DQSM 1222 DQ 8x24 VDC 16x24 VDC 6ES7 222-1HF30-0XB0 SM 1222 DQ 8xRelay 20.4 V 20.4 V 5 V 5 V 28.8 V 28.8 V 30 V 30 V 6ES7 222-1HH30-0XB0 SM 1222 DQ 16xRelay 120 ma 140 ma 120 ma 135 ma 11 ma/relay coil 11 ma/relay coil (without load), max. Power losses Power loss, typ. 1.5 W 2.5 W 4.5 W 8.5 W Digital inputs Number/binary inputs 0 0 0 0 Digital outputs Number/binary outputs 8 16 8 16 In groups of 1 1 2 1 Functionality/short-circuit strength No; to be provided No; to be provided No; to be provided No; to be provided Page 794 Mar 2008 Siemens ITS

Limitation of inductive typ. (L+) -48 typ. (L+) -48 shutdown voltage to V V Switching capacity of the outputs with resistive load, max. 0.5 A 0.5 A 2 A 2 A on lamp load, max. 5 W 5 W 30 W DC ; 200 W AC Output voltage Rated value (AC) 5 to 250 V 30 W DC ; 200 W AC 5 to 250 V AC AC Rated value (DC) 24 V 24 V 5 to 30 V DC 5 to 30 V DC for signal "0" (DC), max.0.1 V; with 10 kohm load 0.1 V; with 10 kohm load for signal "1", min. 20 V DC 20 V DC Output current for signal "1" rated value 0.5 A 0.5 A for signal "1" permissible range, max. for signal "0" residual 10 µa 10 µa current, max. Output delay with resistive load 2 A 2 A Page 795 Mar 2008 Siemens ITS

0 to "1", max. 50 µs 50 µs 10 ms 10 ms 1 to "0", max. 200 µs 200 µs 10 ms 10 ms Aggregate current of outputs (per group) horizontal installation 4 A; Current up to 50 C, max. per mass Cable length Cable length, shielded, max. 8 A; Current per mass 10 A; Current per mass 500 m 500 m 500 m 500 m Cable length unshielded, 150 m 150 m 150 m 150 m max. Relay outputs Number of relay outputs 8 16 Rated input voltage of 24 V 24 V relay L+ (DC) Number of operating cycles mechanically 10 million, at rated load voltage 100,000 Switching capacity of contacts with inductive load, max.0.5 A 0.5 A 2 A 2 A 10 A; Current per mass mechanically 10 million, at rated load voltage 100,000 Page 796 Mar 2008 Siemens ITS

on lamp load, max. 5 W 5 W 30 W DC ; 200 W AC 30 W DC ; 200 W AC Switching 0.5 A 0.5 A 2 A 2 A frequency/contacts/at ohmic load/maximum Interrupts/diagnostics/statu s information Alarms Alarms Yes Yes Yes Yes Diagnostic alarm Yes Yes Yes Yes Diagnoses Diagnostic functions Yes Yes Yes Yes Diagnostics indication LED For status of the outputs Yes Yes Yes Yes for maintenance Yes Yes Yes Yes Status indicator digital Yes Yes Yes Yes output (green) Galvanic isolation Galvanic isolation digital outputs between the channels Relay Relay Page 797 Mar 2008 Siemens ITS

between the channels, in groups of between the channels and the backplane bus Permissible potential difference between different circuits Climatic and mechanical conditions for storage and transport Climatic conditions for storage and transport Free fall Drop height, max. (in packaging) Temperature 1 1 2 4 500 V AC 500 V AC 1500 V AC for 1 minute 0.3 m; five times, in dispatch package -40 C to Permissible +70 C temperature range Air pressure acc. to IEC 60068-2-13 0.3 m; five times, in dispatch package 750 V AC for 1 minute 0.3 m; five times, in dispatch package -40 C to +70-40 C to +70 C C 1500 V AC for 1 minute 750 V AC for 1 minute 0.3 m; five times, in dispatch package -40 C to +70 C Page 798 Mar 2008 Siemens ITS

Permissible air pressure Mechanical and climatic conditions during operation Climatic conditions in operation Temperature Permissible temperature range Permissible temperature change Degree and class of 1080 to 660 hpa 0 C to 55 C horizontal installation 0 C to 45 C vertical installation 5 C to 55 C, 3 C / minute 1080 to 660 hpa 0 C to 55 C horizontal mounting 0 C to 45 C vertical mounting 95% noncondensing humidity 5 C to 55 C, 3 C / minute 1080 to 660 hpa 0 C to 55 C horizontal installation 0 C to 45 C vertical installation 5 C to 55 C, 3 C / minute 1080 to 660 hpa 0 C to 55 C horizontal installation 0 C to 45 C vertical installation 5 C to 55 C, 3 C / minute Page 799 Mar 2008 Siemens ITS

protection IP20 Yes Yes Yes Yes Standards, approvals, certificates CE mark Yes Yes Yes Yes C-TICK Yes Yes Yes Yes FM approval Yes Yes Yes Yes Connection method required front connector Yes Yes Yes Yes Mechanics/material Type of housing (front) Plastic Yes Yes Yes Yes Dimensions Width 45 mm 45 mm 45 mm 45 mm Height 100 mm 100 mm 100 mm 100 mm Depth 75 mm 75 mm 75 mm 75 mm Weight Weight, approx. 180 g 220 g 190 g 260 g More information Brochures Information material for downloading can be found in the Internet: http://www.siemens.com/simatic/printmaterial Page 800 Mar 2008 Siemens ITS