Siemens AG ED CB00-0BA0 6ED HB00-0BA0 6ED MB00-0BA1 6ED FB00-0BA1 Supply voltages Rated value
|
|
- Caitlin Lynch
- 5 years ago
- Views:
Transcription
1 Siemens AG 008 Overview Expansion modules for the connection to LOGO! Modular With digital inputs and outputs, analog inputs or analog outputs Technical specifications 1CB00-0BA0 1HB00-0BA0 1MB00-0BA1 1FB00-0BA1 DC 1 V DC 4 V DC 115 V DC 30 V range, 0.4 V 0.4 V 10.8 V 100 V lower limit (DC) range, upper limit (DC) 8.8 V 8.8 V 8.8 V 53 V AC 4 V AC 115 V AC 30 V range, 0.4 V 85 V lower limit (AC) range, 6.4 V 65 V upper limit (AC) Digital inputs Number of digital inputs Digital outputs Number of digital outputs 4 4; Relay 4; Relay 4; Relay Short-circuit protection of the output ; electrical (1 A) No; external fusing No; external fusing No; external fusing Relay outputs Switching capacity of the contacts with inductive load, 3A 3A 3A with resistive load, 5A 5A 5A Thermal continuous 0.3 A current, Emission of radio interference to EN (limit class B) Siemens ST /15
2 Siemens AG 008 1CB00-0BA0 1HB00-0BA0 1MB00-0BA1 1FB00-0BA1 Environmental requirements min. 0 C 0 C 0 C 0 C 55 C 55 C 55 C 55 C IP 0 Standards, approvals, CSA approval developed to IEC1131 FM approval to VDE 0631 Marine approval UL Approval rail, spacing rail, spacing rail, spacing rail, spacing Width 36 mm; TE 36 mm; TE 36 mm; TE 36 mm; TE Height 90 mm 90 mm 90 mm 90 mm Depth 55 mm 55 mm 55 mm 55 mm Supply voltages DC 4 V DC 115 V DC 30 V 0.4 V 0.4 V 100 V limit (DC) limit (DC) 8.8 V 8.8 V 53 V AC 115 V AC 30 V 85 V limit (AC) 65 V limit (AC) 47 Hz limit 63 Hz limit Digital inputs Number of digital inputs Input voltage for signal "0" < 5 V DC < 5 V DC < 40 V AC; < 30 V DC for signal "1" > 1 V DC > 1 V DC > 79 V AC; > 79 V DC Input current for signal "0", 1mA 1mA 0.03 ma (permissible quiescent current) for signal "1", ma ma 0.08 ma typ. Input delay (for rated value of input voltage) for standard inputs - at "0" to "1", 1.5 ms 1.5 ms 50 ms - at "1" to "0", 1.5 ms 1.5 ms 50 ms /16 Siemens ST
3 Siemens AG 008 Digital outputs Number of digital outputs Short-circuit protection of the output Lamp load, Controlling a digital input Parallel switching of outputs for increased power Switching with resistive load, with inductive load, mechanical, Relay outputs Switching capacity of the contacts with inductive load, with resistive load, Thermal continuous current, 8 8; Relay 8; Relay ; electrical (1 A) No; external fusing W; 500 W at 115 V AC No No No 10 Hz Hz Hz 0.5 Hz 0.5 Hz 0.5 Hz 0.3 A 10 Hz 10 Hz 3A 5A external fusing W; 500 W at 115 V AC 3A 5A Emission of radio interference to EN (limit class B) Environmental requirements Operating temperature min. 0 C 0 C 0 C 55 C 55 C 55 C Degree of protection IP 0 Standards, approvals, CSA approval developed to IEC1131 FM approval to VDE 0631 Marine approval UL Approval Width 7 mm; 4 TE 7 mm; 4 TE 7 mm; 4 TE Height 90 mm 90 mm 90 mm Depth 53 mm 53 mm 53 mm DC 1 V DC 4 V Analog inputs Number of analog inputs Voltage Current voltages 0 to +10 V currents 0 to 0 ma resistance thermometers Pt 100 Resistance thermometer Siemens ST /17
4 Siemens AG 008 Emission of radio interference to EN (limit class B) Environmental requirements min. 0 C 0 C 55 C 55 C IP 0 Standards, approvals, CSA approval developed to IEC1131 FM approval to VDE 0631 Marine approval UL Approval rail, spacing rail, spacing Width 36 mm 36 mm Height 90 mm 90 mm Depth 55 mm 55 mm 1MM00-0BA0 DC 1 V No DC 4 V Analog outputs Number of analg outputs Output ranges, voltage 0 to 10 V Emission of radio interference to EN (limit class B) Environmental requirements min. 0 C 55 C IP 0 Standards, approvals, CSA approval developed to IEC1131 FM approval to VDE 0631 Marine approval UL Approval rail, spacing units wide Width 36 mm Height 90 mm Depth 55 mm /18 Siemens ST
5 Siemens AG 008 Ordering Data Order No. Order No. LOGO! DM8 4 1CB00-0BA0 Accessories 4 V DC supply voltage, LOGO! manual 4 digital inputs 4 V DC, 4 digital outputs 4 V DC, 0.3 A German 6ED AA00-0AE7 LOGO! DM16 4 English 6ED AA00-0BE7 4 V DC supply voltage, French 6ED AA00-0CE7 8 digital inputs 4 V DC, Spanish 6ED AA00-0DE7 8 digital outputs 4 V DC, 0.3 A Italian 6ED AA00-0EE7 LOGO! DM8 1/4R 1MB00-0BA1 Chinese 6ED AA00-0KE7 1/4 V DC supply voltage, 4 digital inputs 1/4 V DC, LOGO! memory card 6ED DA00-0BA0 For copying, with know-how LOGO! DM8 4R 1HB00-0BA0 protection 4 V AC/DC supply voltage, 4 digital inputs 4 V AC/DC, LOGO! DM16 4R 4 V DC supply voltage, 8 digital inputs 4V DC, 8 relay outputs 5 A LOGO! DM8 30R 115/30 V AC/DC supply voltage, 4 digital inputs 115/30 V AC/DC, LOGO! DM16 30R 115/30 V AC/DC supply voltage, 8 digital inputs 115/30 V AC/DC, 8 relay outputs 5 A LOGO! AM 1/4 V DC supply voltage, analog inputs 0 to 10 V or 0 to 0 ma, 10-bit resolution LOGO! AM PT 100 1/4 V DC supply voltage, Pt100 analog inputs, temperature range -50 C to 00 C LOGO! AM AQ 4 V DC supply voltage, analog outputs 0 to 10 V 1FB00-0BA1 1MM00-0BA0 LOGO!Soft Comfort V6.0 B8 6ED BA0-0YA0 For programming on the PC in LAD/FBD; executes on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO!Soft Comfort V6.0 6ED CA0-0YE0 upgrade Upgrade from V1.0 to V6.0 LOGO! PC cable 6ED AA00-0BA0 For transferring programs between LOGO! and the PC LOGO! USB PC cable B9 6ED AA01-0BA0 For transferring the program between LOGO! and PC, including driver on CD-ROM LOGO! News Box, 1/4 V Contains LOGO! 1/4RC, LOGO! USB PC cable, LOGO!Soft Comfort V6.0, manual, screwdriver, information material German B9 6ED BA00-0AA5 English B9 6ED BA00-0BA5 LOGO! News Box, 30 V Contains LOGO! 30RC, LOGO! USB PC cable, LOGO!Soft Comfort V6.0, manual, screwdriver, information material German B9 6ED AA0-0AA0 English B9 6ED AA0-0BA0 LOGO! TD News Box, 1/4 V Contains LOGO! 1/4RCo, LOGO! TD, LOGO! USB PC cable, LOGO! Soft Comfort V6.0, manual, screwdriver, information material German B9 6ED BA10-0AA0 English B9 6ED BA10-0BA0 B8: Subject to export regulations: AL: N and ECCN: EAR99S B9: Subject to export regulations: AL: N and ECCN: EAR99T Siemens ST /19
6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0
Overview The compact high-performance CPU With 2 integral input/outputs Expandable by: - 1 signal board (SB) or communication board (CB) - 8 signal modules (SM) - Max. 3 communication modules (CM) Technical
More informationType: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description
Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationType: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description
Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals
More information3TK28 Safety Relays. General data. 7/70 Siemens LV
3TK28 Safety Relays General data Overview SIRIUS safety relays are the key elements of a consistent and cost-effective safety chain. Be it EMERGENCY-STOP disconnection, protective door monitoring or the
More informationSIREC D MP SIREC D200 SIREC D300 SIREC D400 : MP , CA 01. : E86060-D4001-A110-C (CD-ROM) E86060-D4001-A510-C (DVD) SIREC D
SIREC D MP 20-2007 SIREC D MP 20 2007 SIREC D200 SIREC D300 SIREC D400 : MP 20 2005,, CA 01. : E86060-D4001-A110-C5-7600 (CD-ROM) E86060-D4001-A510-C5-7600 (DVD) Siemens Siemens AG 2007 SIREC D,, - -,
More information3TX7, 3RS18 Coupling Relays
TX7, RS18 Coupling Relays TX7 Coupling Relays, Narrow Design Relay couplers Siemens AG 2010 Application AC and DC operation EN 60947, EN 60664-1 and EN 50005. In the coupling links in double-decker design,
More informationTemperature Measurement
Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationElectronic circuit protector REX12
Description The new electronic overcurrent protection REX12 consists of the supply module EM12-T and the single or double channel electronic circuit protector REX12-T which allows modular side-by-side
More information02/11/2015
Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine
More informationSITRANS T measuring instruments for temperature
Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.
More informationInverter MICROMASTER 410
Inverter MICROMASTER 40 /2 Description /4 Circuit diagrams /6 Technical data /7 Selection and ordering data /8 Options /0 Dimension drawings Siemens DA 5.2 2005/2006 / MICROMASTER 40 Description Inverter
More information"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting
Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input
More informationFM 355 CONTROLLER MODULE
FM 355 CONTROLLER MODULE Function The FM 355 has 4 separate closed-loop control channels. The controllers display the features: Standard control structures (depending on the control structure selected,
More informationSM 1222 DIGITAL OUTPUT MODULE
SM 1222 DIGITAL OUTPUT MODULE Overview Digital outputs as supplement to the integral I/O of the CPUs For flexible adaptation of the controller to the relevant task For subsequent expansion of the system
More information3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching
Main Characteristics: Zero-point switching LED display Various connection technologies Plug-in control terminal Degree of protection IP 2 Insulated mounting foot Standards / Approvals: DIN EN 697--3 UL
More information02/11/2015
Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions
More informationSM 1223 DIGITAL INPUT/OUTPUT MODULE
SM 1223 DIGITAL INPUT/OUTPUT MODULE Overview Digital inputs and outputs as supplement to the integral I/O of the CPUs For flexible adaptation of the controller to the relevant task For subsequent expansion
More informationTemperature Measurement
Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective
More informationLevel instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview
Overview is a 4-wire, 6 GHz pulse radar level transmitter for continuous and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Auto False-Echo Suppression Infrared
More informationREX12 Electronic Circuit Protector
Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double
More informationOutput of three-phase motors at 50 Hz and 400 V
RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More information02/11/2015
"Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue
More informationDZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories
DZD 92 L Multi-Function - Multi-domain time relay Mono voltage 8 Functions Setting range 0.05 s to 100 h subdivided into 7 time domains 1 immediate-action and 1 time contact or 2 time contacts (adjustable)
More informationATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW
Characteristics soft starter for asynchronous motor - ATS01-6 A - 380..415V - 1.5..3 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationSIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE
SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE Function The SM 1234 analog input/output signal modules convert analog signals from the process into digital signals for internal processing by the SIMATIC S7-1200.
More informationTemperature Measurement Transmitters for mounting in sensor head
Siemens AG 015 SITANS TH00 two-wire system, universal Overview Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection
More informationTechnical Information itemp TMT180
TI00088R/09/EN/14.16 71315611 Technical Information itemp TMT180 Temperature head transmitter for resistance thermometers Pt100 Configurable using a PC, for installation in a terminal head, form B Application
More informationCustom "Compact" range with display CD20 Custom Part number
Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationAdditel 875 Series Dry Well Calibrators
Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationSEN TRONIC AG. Millenium 3 Essential. Essential range: powerful but cost effective. Part numbers. Accessories
Millenium Essential Essential range: powerful but cost effective Industrial temperature range (0 C +55 C) Analog inputs 00 DC, Potentiometer (00 ma/pt00 with converters) Display versions: Green LCD with
More informationSubject to changes 11/2003 Page 1/7
Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3
More informationSIMATIC S7-300 Function modules
Overview Technical specifications 6ES7 30-1AH03-0AE0 Supply voltage Aux. voltage 1L+, load voltage 2 L+ Rated value (DC) 24 V Permissible range (ripple included) - dynamic, lower limit (DC) 18. V - dynamic,
More informationSolid-State Switching Devices
SIRIUS Solid-State Switching Devices Contents Pages Introduction.................................. 8/2 Solid-state switching devices General data.................................. 8/3 Solid-state switching
More informationSITRANS T measuring instruments for temperature
SITRANS T measuring instruments for temperature /2 Product overview /6 Transmitter for mounting in sensor head /6 SITRANS TH100, two-wire system (Pt100) /9 SITRANS TH200, two-wire system universal /15
More informationElectronic timer CT-MFS.21
2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the
More information6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)
6ES7214-1AG31-0XB0 Page 1 Product data sheet 6ES7214-1AG31-0XB0 SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V
More informationSolid-State Soft Starters
Selection and ordering data Rated operational voltage U e V Soft starters for three-phase asynchronous motors 3RW30 25-1B14 3RW30 35-1B14 t ambient temperature 40 C Size Order No. Price Weight Pack. Rated
More informationCPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226
Siemens AG 2008 SIMATIC S7-200 Overview CPU 226 The high-performance package for complex technical tasks With additional PPI port for added flexibility and communication options With 40 inputs/outputs
More informationPOINTAX 6000L2 Point Recorder
GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,
More informationLevel Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI
Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationLight-strip indicator
/2 s /2 PROLUX 96 x 24 mm with 5 segments, /6 PROLUX 144 x 24 mm with 101 segments, /10 PROLUX 144 x 6 mm with 71 segments, Siemens MP 12 200 PROLUX 96 x 24 mm with 5 segments, Design The PROLUX light-strip
More informationTechnical Information RMA42
TI00150R/09/EN/05.16 71315973 Products Solutions Services Technical Information RMA42 Process transmitter with control unit Digital process transmitter for monitoring and visualizing analog measured values
More information3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.
Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationLINAX 4000L Continuous-line recorder
-48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged
More informationTemperature transmitter itemp RTD DIN rail TMT 127
Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,
More informationTransformers, Power Supply Units and Socket Outlets
Transformers, Power Supply Units and Socket Outlets /2 Introduction /3 4AC3 bell transformers /4 4AC3 safety transformers /5 4AC2 power supply units /6 5TE6 REG socket outlets For further technical product
More informationElectronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet
CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication
More informationATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW
Characteristics soft starter for asynchronous motor - ATS01-22 A - 200..240 V - 4..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationElectronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationInverter MICROMASTER 420
Inverter MICROMASTER 40 / Description /4 Circuit diagrams /6 Technical data /8 Selection and ordering data /9 Options /18 Dimension drawings Siemens DA 51. 005/006 /1 MICROMASTER 40 Description Applications
More informationTemperature head transmitter itemp TC TMT 188
Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed
More informationATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW
Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW
Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationTemperature Transmitter itemp RTD DIN rail TMT 127
Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed
More informationRMA42. Technical Information
Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and
More information1 Overview. Continuous Gas Analyzers, extractive CALOMAT 62. 1/168 Siemens AP US Edition. General information
General information Overview The gas analyzer is primarily used for quantitative determination of one gas component (e.g. H 2, N 2, Cl 2, HCl, NH 3 ) in binary or quasi-binary gas mixtures. The is specially
More informationSIMATIC S5. ET 100U Distributed I/Os. Manual. EWA 4NEB a
SIMATIC S5 Distributed I/Os Manual EWA 4NEB 8 6040-0a STEP and SIMATIC are registered trademarks of Siemens AG Copyright Siemens AG 988 Subject to change without prior notice. The reproduction, transmission
More informationATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-32 A - 200..480V - 7.5..15 KW Main Range of product Product or component type Product destination Product specific application Device short
More informationATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW
Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationTORKEL 900-series Battery Load Unit
TORKEL 900-series Batteries can be tested in service Dynamic discharge technology full power at all voltages Safety in all details, e.g. detection of blocked airflow Real time monitoring during test Easy
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More informationEGSTON POWER SUPPLY N2xxSW 12W
General description This document describes a switch mode power supply unit (AC/DC converter). The unit is designed as wall plug device. It is available with a plug for Europe, US (Japan, Canada) and UK
More informationElectronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact The CT-MVS.12 is a multifunctional electronic timer from the CT-S range and provides 10 timing functions and 10 time ranges.
More informationJUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationElectronic timer CT-SDS.22
CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication
More informationATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-22 A - 200..480 V - 4..11 KW Price* : 195.00 GBP Main Range of product Product or component type Product destination Product specific application
More informationSIRIUS/SIKOSTART Soft Starters For Standard Applications
Overview SIRIUS RW0/1 Various versions of the RW0/1 SIRUS soft starters are available: Standard version for fixed frequency three-phase motors, sizes S00, S0, S2 and S Version for fixed-speed three-phase
More informationTORKEL 900-series Battery Load Unit
Batteries can be tested in service Dynamic discharge technology full power at all voltages Safety in all details, e.g. detection of blocked airflow Real time monitoring during test Quick report Easily
More informationAdditel 875 Series Dry Well Calibrators
Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect
More informationREX12 Electronic Circuit Protector
Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double
More informationFor Immediate Delivery call KMParts.com at (866)
Contents 9/1 Page Description SN4 switched-mode power supply units 9/2 GW4 power supply units 9/3 GD4 power supply units 9/4 Basic Units, Accessories 9/5 Technical data 9/6 Dimensions 9/12 9/2 Description
More informationDigital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC
Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC Properties 1 Parameters 2 Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) Manual
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationâ itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring
Technical information itemp Pt100 TMT127 Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring Application Temperature transmitter with fixed measuring range for converting a
More informationTemperature Measurement Transmitters for mounting in sensor head
Siemens AG 015 Overview SITANS TH00 two-wire system, universal, HAT Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection
More informationOvercurrent Protection / 7SJ45
Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers
More informationQUINT-PS-24DC/24DC/10
QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage
More informationNo-wear isolation of potentials in terminal block design
TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationTT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H
Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de TT2780 Data Sheet TT2780
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationHighlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable
Siemens G 008 SIMTIC PXI inductive proximity switches Introduction Inductive proximity switches rugged, accurate and reliable PXI series The inductive proximity switches are organized in different product
More informationMACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:
Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer
More informationJUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver
Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More information