Power distribution system SVS25

Similar documents
Power Distribution System SVS18

Power Distribution System SVS20

Electronic circuit breaker ESS30-Sxxx-DC24V

Power Distribution System SVS02

Power Distribution System SVS02

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Electronic circuit protector REX12

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Protector ESX10-T

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS1 for System SVS1

REX12 Electronic Circuit Protector

PHOENIX CONTACT

Electronic Circuit Protector ESX10

REX12 Electronic Circuit Protector

Electronic Circuit Breaker ESS1 for System SVS1

Smart Power Relay E I...

PHOENIX CONTACT

Solid State Remote Power Controller E

Datasheet. Electronic Circuit Protection ESX10-T

PHOENIX CONTACT - 09/2009

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

Switching power supplies CP range, Linear power supplies CP-L range. Content

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

EPSITRON Electronic Circuit Breakers For Secondary Side DC Protection

PowerPlex Compact Module PP-C-COM24

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Installation and Operating Instructions for Phase Demodulator Type _.2

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

COMPACT LED DRIVERS. ComfortLine Selectable Current (LEDset) ComfortLine SELECTABLE CURRENT LEDset ,

MINI-PS AC/24DC/1.3

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Device circuit breakers Selective power distribution: branch out, individual adaptation, modular extension

Industrial motor controller for brushed DC motors 24 VDC

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Electronic circuit protector ESX10-Sxxx-DC24V-1A-10A

Industrial motor controller for brushed DC motors 24 VDC

QUINT-PS/ 3AC/24DC/10

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Power supply CP-T 24/20.0 Primary switch mode power supply

Type CP-S, CP-C & CP-A Switch mode

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

QUINT-PS/ 3AC/24DC/40

Adjustable Digital Process Instrument MDK480

EPSITRON Electronic Circuit Breakers Compact and Precise ECBs for DC Circuits

Industrial motor controller for brushed DC motors 12 VDC

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

SITOP power supply: The standard for reliability, compactness, and functionality. Reliably supplies 24 V DC.

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

MRG 512-PRO PQ Flex Mobile universal measurement device Supplementary description to the operation manual UMG 512-PRO

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Components Pole desig. Coding Design Part number Connector, screw Device connector M25, screw Device connector M20, screw, straight

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

MINI-PS AC/2X15DC/1

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-E 24/2.5

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

QUINT-PS/ 1AC/24DC/20

QUINT-PS AC/24DC/40

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Electronic Circuit Breaker BASIC FIX

EPSITRON Advanced Power Supply System. High-Performance Meets High-Efficiency

MRG 96RM-E Flex RCM Mobile universal measurement device Supplementary description to the operation manual UMG 96RM-E

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

ECM3 EARTH CONTINUITY RELAY

Power supply CP-E 24/0.75

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Power supply CP-E 24/2.5

MODEL: M2DYS SEN TRONIC AG

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Power supply CP-T 48/5.0 Primary switch mode power supply

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

Power supply CP-E 24/20.0

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

Level Switch NRS 2-50 NRS Original Installation Instructions English

SCS Automation and Control Ltd

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

3B SCIENTIFIC PHYSICS

Totally Integrated Power SIVACON 8PS LDM busbar trunking system siemens.com/ldm-system

HARTING. Value Added Solutions

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Transcription:

Power distribution system SVS Description The new power distribution system type SVS meets all requirements of the automation technology with regard to reliably overcurrent protection and optimised current distribution. NEW The track-mountable power distribution system SVS distributes the voltage potentials supplied by a DC V switch-mode power supply to slots and selectively protects the connected loads by means of the plugged in circuit protector type REF-S0-DCV. The SVS simplifies wiring and distribution with a load current of 0A per way and a max. total current of 0A in short-circuit-limited DC V applications. 0 protected»+«load outputs and 0 minus terminals per slot help significantly reduce wiring time. Any load circuit which might be disconnected due to overload or short circuit generates a single signal which will be summarised in a group signal directly on the power distribution system and which will be fed back directly to the control unit. The line entry for the DC V supply as well as the load output terminals are designed as push-in terminals so that the entire system can be wired quickly and cost-effectively. Suitable for the following types: Electronic circuit protectors Features and Benefits l Systematic integration of protection and distribution functions l Power distribution and selective protection of DC V load circuits all in one l Clearly laid-out distribution concept l Profitability through considerably reduced wiring time l Reduction of planning, design and installation time l Ease of maintenance, diagnosis and system extension l Compact power distribution for compact control cabinets l 0 plus and minus terminals per slot l Integral group signalling Order numbering code Type SVS SVS power distribution system for REF-S l for short-circuit limited DC V applications l max. 0 A cont. load l group signalling terminals X included, DCV / max. 0. A, has to be protected separately Max. number of circuit protectors on the distribution system 0 circuit protectors [F...F) Population, load output, minus and signalling terminals 00 completely fitted with push-in terminals (max.. mm, without wire end ferrule) 0-00 ordering example REF-S0 REF-S00 (without signalling) Technical data (T amb = C, U B = DC V) Application: Modular power distribution system for short circuit current limited DC V applications Supply Rated voltage: DC V (...0 V) Total current max. 0 A DC V (+) = X + / + DC V (-) = X - / - Terminals x -pole push-in terminals max. 0 mm, for power supplies integral loop-through, for sub-wiring cable cross section (with plastic sleeve) 0. 0 mm stripped length mm F-slots slots for circuit protectors, prepared for types REF-S0- / REF-S00- F...F ) = terminals X...X outputs, load output (+) and load output (-) per way (X...X) Rated voltage DC V (...0 V) Current max. 0 A per terminal block ( to 0) terminals: 0 x //////////0 protected per slots F...F ) led out to terminals X...X. Minus terminals: Terminals: 0 x //////////0 protected per slots F...F ) led out to terminals X...X. push-in terminal block, x -pole max. cable cross section (with plastic sleeve) 0.. mm (without plastic sleeve) 0.. mm stripping length mm Accessories: see page "accessories" ) When mounted side-by-side and fully equipped with the circuit protectors REF-Sxxx rated 0A the devices can only carry 0% of their rated load continuously. 0/ www.e-t-a.de -

Power distribution system SVS Technical data (T amb = C, U B = DC V) Mounting position Signalling Rated voltage: DC V (... 0 V) Total current max. 0. A Signal terminal X for group signalling Si External supply + DC V for aux. circuit (max. 0. A) Si Output aux. circuit (max. 0. A) Terminals: General data Mounting of housing Temperature range Storage temperature Housing material Degree of protection Insulation voltage Dimensions Mass -pole screw terminals push-in terminals max.. mm max. cable cross section (with plastic sleeve) 0.. mm (without plastic sleeve) 0.. mm stripping length mm symmetrical rail to EN 0 - x. 0...0 C (without condensation) -0...+0 C moulded terminals IP0 DIN 000 printed circuit board IP00 DIN 000 (double coating) DC 0V (pcb) see dimensions (tolerances to DIN ISO part IT) SVS0-0-00 approx. g Notes for installation l The max. total current of 0A per way must not be exceeded l The user has to ensure that the cable cross section of the load circuit in question complies with the current rating of the used load or circuit protector. l The technical data of the circuit protector have to be observed. l In addition special precautions must be taken in the system or machine (e.g. use of a safety PLC) which reliably prevent an automatic re-start of parts of the system (cf. Machinery Directive 00//EG and EN 00-, Safety of Machinery). In the event of a failure (short circuit/overload) the load circuit will be disconnected by the circuit protector. l The power distribution system must only be installed by qualified personnel. l It is only intended for use with safety extra-low voltage (= V DC). l Only after expert installation must the device be supplied with power. l After tripping of the circuit protector, before reset, the cause of short circuit or overload has to be remedied. l The national standards (e.g. for Germany DIN VDE 000) have to be observed for installation and selection of feed and return cables. l Connection to a higher or not reliably disconnected voltage can cause hazardous conditions or damages. - www.e-t-a.de 0/

Power distribution system SVS Schematic diagram SVS-0-00 -A F F F F X DCV / max. 0, A DCV / max. 0 A + + - - X SI SI X. X. X. X. X. X. X. X. 0 0 0 0 0 0 0 0 Dimensions SVS-0-00 top hat rail EN 00-x. (not supplied with product) 0 ca. Typ: SVS-0-00 DCV/0A X 0 + + - - F F F F F F F F X. + X.- X.+ X. - X. - X. - X. + X. - X. + X. - X. + X. - X. + X. - X.+ X.- X Si Si DCV/max. 0. A 0 terminals power supply push-in terminals 0.0 mm x -pole max. 0 A signalling terminals push-in terminals -pole. mm max. 0. A load output terminals push-in terminals x 0 pole. mm max. 0 A load output and signalling terminals. mm wire end ferrule with plastic sleeve. mm wire end ferrule without plastic sleeve Please order the required population option separately. 0/ www.e-t-a.de -

Power distribution system SVS Application example: SVS-0-00 fitted with REF-S 0 ca. REF-S... Typ: SVS-0-00 DCV/0A X 0 + + - - F F F F F F F F X. + X.- X.+ X. - X. - X. - X. + X. - X. + X. - X. + X. - X. + X. - X.+ X.- X Si Si DCV/max. 0. A 0 SVS-0-00, empty SVS-0-00 fitted with REF-S Please order the required population option separately. - www.e-t-a.de 0/

Power distribution system SVS Application example: jumper instead of circuit protector (e.g. REF-S0) If the power distribution system is not completely fitted with circuit breakers, the subsequently open signal way can be closed with the plugged-in jumper type SB-S-P-0--A. The signal way of the group signalisation goes - after supply of the +DC V potential in X, Si - via the plugged-in juimper and - via all aux. N/O contacts Si () / Si () of the used circuit protector types REF-S0, - back to the signal output of the group signal X, Si In the OK condition (i.e. all circuit protectors plugged in and operating) the signal way X, Si to X, Si is closed. Schematic diagram SVS-0-00 signal path X +DCV Si SC SC SC SC SC SC SC SC OUT Si -F -F -F -F -F -F -F -F SO SO SO SO SO SO SO SO SVS-0-xxx with REF-S0 and SB-S-P-0--A Typ: SVS-0-00 DCV/0A X + + - - X. + F X.- X.+ F X. - X. - F X. - X. + F X. - X. + F X. - X. + F X. - X. + F X. - X.+ F X.- X Si Si DCV/max. 0. A 0 0/ www.e-t-a.de -

Jumper SB-S-P-0--A Accessories Schematic diagram Jumper: for insertion in empty slots instead of circuit breakers for bridging the looped-through auxiliary contacts (series connection) SB-S-P-0--A,, (a) (c) max. A xxxx Signal jumper (a)-(c) SB-S-P-0--A (a) (c) auxiliary circuit (Si) load max. A All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. - www.e-t-a.de 0/