Compact Preset Counter

Similar documents
Position Indicator with/without Limit Values

Multifunctional counter tico 772/773/774

Typical applications:

Flexible Counter Series in DIN size 24 x 48 mm

Pulse Scaler for DIN Rail Attachment

Single and Dual Preset Counters Hengstler signo 721 series

Totalizing Counters mini-i

Preset counters, electronic

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

Solid-state Timer H3DS

Solid-State Digital Counter H7AN

Device manual Multifunction display and evaluation system FX 360. Mode/Enter

05/09/2014

Counters Totalising counters, predetermining counters and totalising timers

02/11/2015

Count/Time Totalizers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Indicator (4digit) (5digit) 8-pin plug counter

Technical Data Sheet. x1000. kwh R Y B

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Process displays For standard signals, temperature, resistance measurement

Rotational speed controller

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Self-Powered Counters H7ET

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

02/11/2015

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Bulletin 700-HX Multifunction Digital Timing Relay

Operating Instructions

DIGEM f 96 x 48 EK. Applications. Description

CONTA-ELECTRONICS. Converter Units

Operating Instructions

BATCHMATE 1500 Batch Control Computer Technical Bulletin

NPN PNP NPN PNP NPN PNP

08/07/2015

Contrast scanners detect the little differences

Operating instructions KC-LCDC. Electronic Preset Counter with two presets FACTORY AUTOMATION

02/11/2015

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Digital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions

Measurement and Instrumentation

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Analogue temperature controllers

02/11/2015

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

RATE / TOTAL / BATCH METERS INF7

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

FX-CM. HQ Color Mark Sensor. Model Number Legend SALIENT FEATURES. Sensors. Proximity. Photoelectric. Sensors

05/09/2012

XIOC technology and networking modules

02/11/2015

Limit Switch Style Inductive Prox

02/11/2015

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

em4 local - Robust Specific characteristics Part number

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

08/07/2015

22/10/2012

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

E2Q5. Square Proximity Sensor. Long Distance Square Inductive Proximity Sensor. Ordering Information

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Solid-state Timer H3DE

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

2000 h at 25 C Battery, charging time h at 25 C Battery, charging time. 8 mm 8 mm via push-button decade switches

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Type Nominal voltage (V) Code HSV V

ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222

Energy Management Three-phase energy meter with output modules Type EM4-DIN

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Model Number Structure

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

AMIK 200 / 201 Technical Data Sheet

Leuze electronic. 3 Series. Product description

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

Indicators and configurable displays

GEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)

APPENDIX APPENDIX A 1

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

WHEN A PLC IS TOO MUCH, AND SPACE FOR

Solid-state Timer H3DS

Photoelectric Sensors XUV Sensors with Separate Optical Heads

Remote Sensor Amplifier Terminal

Solid-state Timer H3DS

Product Data Sheet 3252J/2H3PU

Absolute encoders - SSI

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Absolute Encoders Singleturn

Fuzzy Temperature Controllers E5AF

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

CompoBus/D-type Digital Controller

Transcription:

signo 721 Compact Preset Counter 1 or 2 presets Prescaler with output for connection of a totalizing counter Large, 5-digit LD display Connection by plug-in screw terminals Variety of programming possibilities Small, compact design in DIN dimensions 48 x 48 mm Keypad can be secured against unauthorized access lectronic value retention, environmentally sound, uses no batteries DISPLAY 5-digit LD display with 7 mm high digits. asy to read, decimal point can be programmed if required. Line 1: Shows the current count in counting operation and entry values in programming mode. Line 2: Shows the operator the individual programming steps during programming. VALU INPUT Values shown in the diagrams can be entered or modified with four large keys on the front of the counter. Counter with one preset P Preset COR Correction Prescaler Counter with two presets P1 Preset 1 P2 Preset 2 COR Correction PSC Prescaler Value input Value input PROGRAMMING Counter with gate and display memory Counter with up/down Table (Page 78) Auto- Key 1 Off see Key 2 Off Key- Lock Input 5kHz Display-Hold Off Inhibit Off pnp-input 9 8 7 6 5 4 3 2 1 Set Off 30Hz npn Table (Page 78) Auto- Key 1 Off see Key 2 Off Key- Lock Input 5kHz pnp-input 9 8 7 6 5 4 3 2 1 Set Off 30Hz npn Out 0,05s 1s bist. Out 0,05s 1s bist. The switch positions illustrated in the diagram program the counter as follows: 9 Set mode (subtracting count) 8 With automatic repeat 7 Presets, correction value and 6 prescaler can be modified if "keylock" input is not actuated 5 Keypad reset activated 4 Max. counting frequency 5 khz 3 Display memory Off without function 2 Gate to appl. input } for u/d switch 1 pnp input logic Pot Signal duration OUT approx. 1 sec. 140 Components 2000 NCODRS COUNTRS CONTROLLRS INDICATORS RLAYS PRINTRS CUTTRS

Technical data signo 721 TCHNICAL DATA Display 5-digit, LD, decimal point with soldering bridge Digit height 7 mm Supply voltage V op : 12 24 VDC 5/+ 10 % or 24 VAC ± 10 % or 100 240 VAC, depending on version Current consumption on 12 24 VDC < 300 ma, on 24 VAC < 255 ma, on 100 240 VAC < 55 ma Sensor supply AC operation 24 VDC + 10 %, DC operation V op - 2 V Value retention approx. 10 years, NV memory Operating temperature 0 + 50 C Storage temperature 20 + 70 C lectrical connection plug-in screw terminals Protection class (IC 144) front IP 54; connections IP 20 Interference immunity MC severity 3 acc. to IC 801 - pt. 2 + pt. 4 Vibrostability 30 m/s 2 (50... 500 Hz) acc. to IC 068-2-6 Shock stability 100 m/s 2 (10 ms) acc. to IC 068-2-27 General design acc. to DIN VD 0411; insulation group C Weight approx. 200 g Approvals CSA: LR 30208-12-13 Inputs Amplitude thresholds Active edge Pulse shape Input resistance Count input Min. pulse length Max. counting frequency Control inputs Pulse shape Application (Appl.) < 2 V and > 8 V; max. + 40 VDC positive, can be switched to negative random (squarewave 1:1 for max. frequency) approx. 22 kω adding programmable, prescaler, adjustable from 0.001...9.999 > 100 µs / > 17 ms (depending on counting frequency) 5 khz / 30 Hz PNP or NPN (able to switch over) with static behaviour - manual via keypad - electric, pulse length > 17 ms - automatic when OUT2 responds (only if programmed accordingly) full keypad or only preset 1 (depending on program), static behaviour, pulse length > 17 ms gate, up/down or display memory, depending on version Signal must be applied 50 µs before count pulse Outputs Signal outputs OUT1 and OUT2, depending on version Signal duration OUT1: starts when P1 is reached and ends when OUT2 responds OUT2: starts when P2 is reached from 0.05 s... bistable (adjustable) Relay Contact type counter with 1 P: changeover; counter with 2 P: make contact Max. switching voltage max. 250 VAC or 30 VDC Switching current max. 1 A, min. 100 ma on 20 V Transistor Switching voltage AC operation 24 VDC,DC operation V op -2 V Switching current 20 ma Prescaler (PSC-OUT) Switching voltage AC operation 24 VDC ± 10 %, DC operation V op -2 V Switching current max. 10 ma Signal duration typ. 90 µs Components 2000 NCODRS COUNTRS CONTROLLRS INDICATORS RLAYS PRINTRS CUTTRS 141

signo 721 Technical data KYLOCK Counter with 1 preset Counter with 2 presets Keyl 1 Keyl 2 P COR PSC Keyl 1 Keyl 2 P1 P2 COR PSC sw. 7 sw. 6 term. 14 sw. 7 sw. 6 term. 14 off off low A A A off off low A A A A off off high A A L off off high L A A L on off low A A on off low A A A on off high L A L on off high L L A L off on low A L off on low A A L off on high A L off on high L A L on on low A L on on low A A L on on high L L on on high L L L A = active, L = locked, = masked DIMNSIONS Clamping frame Plug connector terminal CONNCTION DIAGRAM Dimensions in mm Counter with 1 preset Counter with 2 presets 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 + AC-DC supply voltage 2 + AC-DC supply voltage NC 3 NC NC 4 OUT1 Relay or NC 5 transistor output 6 NC OUT Relay or 7 OUT2 Relay or transistor output 8 transistor output OV Sensor supply voltage + Input Appl. Prescaler-OUT NC * 9 OV Sensor supply voltage 10 + 11 Input 12 13 Appl. 14 15 Prescaler-OUT 16 NC * * NC = not connected ORDR INFORMATION Counter with: Relay output Transistor output Function Supply 1 preset 2 presets 1 preset 2 presets Ord. code Ord. code Ord. code Ord. code Gate/display hold 12 24 VDC 0 721 101 0 721 105 0 721 103 0 721 107 24 VAC 0 721 109 0 721 110 100 240 VAC 0 721 102 0 721 106 0 721 104 0 721 108 Up/down 12 24 VDC 0 721 121 0 721 125 100 240 VAC 0 721 122 0 721 126 Inquire for other versions 142 Components 2000 NCODRS COUNTRS CONTROLLRS INDICATORS RLAYS PRINTRS CUTTRS

Multifunctional Counter - Bi-directional tico 732 007 high-contrast LD or LCD-Display, 6 digits small and compact DIN dimensions 48 x 48 mm easy operation by one key per digit direct access to parameters available with 1 or 2 presets transistor and relay with changeover contact, for each preset with integrated separate totalizer 5 basic functions easily programmable: counter, tachometer, time counter, shift counter and batch counter display range from 99999 to 999999 PROGRAMMING count mode 6 R 4 F1 F2 PSC PRG F1 F2 PSC PRG 1 2 3 5 6 and POWR ON and POWR ON > 5 sec preset 1 preset 2 prescaler function-parameter e.g. Basicfunction* F1 PRG F2 PRG programming mode PSC PRG count mode decimalpoint reset/set-mode signal length pnp/npn-selection reset mode output memory time countertachometer keylock for: manual reset preset 1 or 2 prescaler counter tachometer time counter shift counter batch counter * only for multifunction version The important values, preset 1, preset 2, prescaler and separate totalizer can be directly selected. It is necessary only to press the relevant button and the -button together. To make the operation still more easy, access to those values can be locked separately. All other system parameters like operation and count modes are laid down in a common operation level. These parameters are usually programmed once only during the first initiation. Components 2000 NCODRS COUNTRS CONTROLLRS INDICATORS RLAYS PRINTRS CUTTRS 131

tico 732 Technical data TCHNICAL DATA General Counter Tacho Time-counter DIMNSIONS Display LD or LCD, 6 digits, leading zero suppression, decimal point Digit height LD 7.6 mm; LCD 9 mm Supply voltage 12...24 VDC; 24 VAC; 115 VAC; 230 VAC; 50/60 Hz, depending on version Current consumption 12...24 VDC < 150 ma 100/115/230 VAC < 50 ma; including sensor supply Sensor supply only when AC operated: 12... 30 VDC, max 50 ma Data retention non-volatile memory > 10 years Operating temperature 0... +50 C Storage temperature - 20... + 70 C lectrical connection screw terminals Mounting with clamping frame Protection class (IC 144) front side IP 65, terminals IP 20 Vibrostability 10 m/s 2 (10...150 Hz) according to IC 68-T2-6 Shock stability 100 m/s 2 (18 ms) according to IC 68-T2-27 General design according to VD 0411, DIN 57411, protection class II Approvals UL + CUL 96337 Amplitude thresholds < 2 V and > 8 V, max 40 VDC Active edge programmable; positive with pnp input; negative with npn input Pulse shape any (squarewave 1:1 for max. frequency) Input resistance approx. 5 kohm (static) Counting frequency max. 5 khz (2.5 khz bi-directional) Prescaler programmable from 0.001 to 9.999 (999.999) Count inputs A, B - phase discriminator with single evaluation - differential mode (add/sub) - count direction mode - totalizing mode (add/add) Pulse length min. 17 ms (30 Hz), 100 µs (5 khz) Control input C - manual reset possible - external reset, static or dynamic, programmable, pulse length > 5 ms - automatic reset when main preset has been reached (programmable) Relay changeover contact max. 250 VAC / 30 VDC, min. 5 V AC/DC max. 1 A, min. 10 ma, delay < 5 ms Transistor pnp output 12...24 VDC max 10 ma of DC-supply; 12 30 VDC max. 10 ma of AC-supply Method time interval (1/Tau) Display range 1/min or 1/sec Min input frequency 0.125 Hz = 8 sec Alarms 2 alarms with programmable start-up-suppression Time bases programmable; sec, min., h or hh.mm.ss Resolution programmable 1; 0.1; 0.01; 0.001 Function single pulse measurement (short time meter) or cumulated counting (hour meter) Count mode pulse width or period measurement (start-stop) Dimensions in mm plug terminal clamping frame 132 Components 2000 NCODRS COUNTRS CONTROLLRS INDICATORS RLAYS PRINTRS CUTTRS

Technical data tico 732 DIMNSIONS VDC 1 Rel/1 Trans VAC 1 Rel/1 Trans VDC 2 Rel/2 Trans VAC 2 Rel/2 Trans For versions with no output, pins 7 9 and 15-17 are not connected. POSSIBL VARIANTS Display Function Outputs Power supply Counter + totalizier no output 12-24 VDC LCD LD Tacho Time counter + totalizer 1 output (1 relay, 1 transistor 100 VAC 115 VAC Shift counter* 2 outputs (2 relays, 2 transistors) 230 VAC Batch counter* ORDR INFORMATION Display Preset 12 24 VDC 24 VAC 115 VAC 230 VAC LCD 0 732 000 0 732 071 0 732 037 0 732 001 LCD 1 0 732 002 0 732 073 0 732 03 1 0 732 003 LCD 2 0 732 012 0 732 078 0 732 049 0 732 013 LD 0 732 018 0 732 080 0 732 055 0 732 019 LD 1 0 732 020 0 732 082 1 0 732 057 0 732 021 LD 2 0 732 030 0 732 087 0 732 067 0 732 031 Important: ly versions with 2 presets or without preset can be used as tachometers. Components 2000 NCODRS COUNTRS CONTROLLRS INDICATORS RLAYS PRINTRS CUTTRS 133