LOS ANGELES WORLD AIRPORTS Terminal Wayfinding Standards

Similar documents
LOS ANGELES WORLD AIRPORTS Terminal Wayfinding Standards

LOS ANGELES WORLD AIRPORTS Terminal Wayfinding Standards

INTERIOR SIGNAGE MANUAL

Summary of Modifications/Changes in this Update

BUILDING SIGN PROGRAM JULY 2012

*********************************************************************************************************

SECTION SIGNAGE

SECTION INTERIOR SIGNAGE

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

SIGN TYPES 3/3/ SIGN TYPES SIGNAGE STANDARDS MANUAL STATION SIGNS. Sign Types 8.0

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

A. Submit properly identified manufacturer's literature before starting work.

BUS RAPID TRANSIT FOURTH PLAIN BLVD

CENTRAL MICHIGAN UNIVERSITY DESIGN STANDARD FOR INTERIOR CAMPUS SIGNAGE - JANUARY 23, 2017

BUILDING SIGN PROGRAM SEPTEMBER 2016

SECTION IDENTIFYING DEVICES

ATTACHMENT B1. Typical Facility Signage Standards and Guidelines/Sign Types

SECTION IDENTIFYING DEVICES

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

SUNSET & FRANCISQUITO SHOPPING CENTER S I G N P R O G R A M

SECTION NON-ILLUMINATED INTERIOR DISPLAY SYSTEM

KNIGHT CANCER INSTITUTE KNIGHT CANCER INSTITUTE

1.1. Any deviance from the following requirements must be approved during design by WVU Facilities Management.

INTERIOR DESIGN INTENT DRAWINGS - condensed version

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SUPPORT ROADS ALL AIRPORT SERVICES BUILDINGS. ONLY CARGO BUILDINGS (Tenants) Sign Types Summary SIGN TYPES - A.SERVICES

This page is intentionally left blank.

PLANNED SIGN PROGRAM CHECKLIST

Americans with Disabilities Act (ADA) Federal Guidelines

APPENDIX 6. SIGNAGE TYPES: Signage as manufactured by KROY Sign Systems, N. Hayden Road, Scottsdale AZ 85260

A. Submit manufacturer's technical data and installation for each type of sign required.

Environmental graphics

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY DWELLING

PHOTOPOLYMER BRAILLE RASTER BRAILLE MOLDED BRAILLE QUICK SHIP ADA BRAILLE SIGNS. Photopolymer sign panel in a variety of thicknesses.

Architectural Excellence

Construction Guidelines 1

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CITY OF RICHMOND Notice of Public Opening. Contract: Richmond Speed Skating Oval Interior/ Exterior Signage Package

DOCUMENT SUBMITTAL REQUIREMENTS FOR AN ALTERATION OR ADDITION TO AN EXISTING SINGLE-FAMILY DWELLING OR MULTI-FAMILY DWELLING

SECTION IDENTIFICATION SIGNS. A. Plastic Signs, raised character, tactile, room identification, exit door signs, and non-tactile signs.

A. Interior and exterior non-illuminated tactile building signs including Braille.

INTERIOR DESIGN INTENT DRAWINGS - condensed version

PROJECT LOCATION BOZEMAN HIGH SCHOOL. ELECTRICAL ENGINEER: Van Dykken Engineering 37 Spanish Peak Drive Bozeman, MT Phone:

Exterior Signage. Design Development 75% 30 November, In collaboration with:

Sign Construction and Implementation Principles

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

Chapter 4. Accessible Routes

SIGN CRITERIA CONSER CROSSING MAJOR TENANTS

Introduction. Page 1. Welcome to the signage guidelines for St John Ambulance premises, updated as of September 2012.

Palm Beach Community College

PALM SQUARE SHOPPING CENTER TENANT SIGN CRITERIA

Addendum for 2018-COA-486 and 2018-COA-487 for the LeRoux and Cho 77 Projecting signs

DRAFT V. SITE ELEMENTS SIGNS

Tenant Sign Criteria. Guidelines. Requirements. Braelinn Village, Peachtree City

SECTION FASCIA INTERIOR FRAMED SIGNS & DIRECTORIES

Chapter 14. Signage Guidelines 14.2 GENERAL DESIGN OBJECTIVES 14.1 INTRODUCTION AND PURPOSE 14.3 GENERAL SIGN DESIGN GUIDELINES

Healthcare Portfolio

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines

LARAMIE COUNTY COMMUNITY COLLEGE Clay Pathfinder Interior Wayfinding Signage AUGUST 11, 2017

2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES

50948-RHN Putney. 14 Dec This document includes: N14 General internal signage systems. Code Section Revision Dated

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

SECTION SWINGING AUTOMATIC ENTRANCES

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

City of Dana Point -- Sign Design Guidelines

CS Restrooms. Parking Garage. All Visitors Must FLOO R. Title. Title Sub-Subtitle Sub-Subtitle Sub-Subtitle. Sub-Subtitle Sub-Subtitle 2A46

Interior Graphics Master Plan Display Manual

CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT CHABOT COLLEGE CAMPUS MASTER SIGN PROGRAM, PHASE 2 BID NO

KONE DESIGN SIGNALIZATION. KSS D20, KSS D50 and KSS D60 series

Elite. PLANNING GUIDE builder & architect edition. AmeriGlide Accessibility Solutions RESIDENTIAL ELEVATOR. ASME A17.1, Part V, Section 5.

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

Letter from the President

A. It is preferred that all submittals to be submitted electronically in PDF format.

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

DRC Page 1. DOWNTOWN SAVANNAH 1 E. Broughton Street Savannah, GA New Build Program CHS.NB.431. Drawing # B78790

OVERVIEW OF SIGN BY-LAW HERITAGE GUIDELINES

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High

Measuring Door Gap Dimensions of Swinging Fire Doors with Builders Hardware

OVERVIEW OF SIGN BY-LAW HERITAGE GUIDELINES

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

ID0.1 PALO VERDE 8000 WEST US HIGHWAY 290 AUSTIN, TX SHEET INDEX: CONTACT INFORMATION: DISCLOSURES: DOCUMENT GENERAL NOTES:

Temporary Sign Permit

Victory Fire Door Inspections

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

CHAPTER 5 SIGNAGE. For the purpose of the Mall Road Overlay Sign District, the following standards shall apply:

Tenant Design Criteria Section k Kiosk Design Criteria Updated: September 2013

DIVISION 12 - FURNISHINGS. Section General Discussion. Introduction

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

SECTION FINISH HARDWARE

Installation Guide. SN-LM42 Brilliance Series Photoluminescent Area of Rescue Signs

ETCHED PLAQUES by Matthews International

1041 Formosa Ave. West Hollywood, CA. October 1, 2013

Design Documents for Wayfinding

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

State College Area School District

A. Product Data: For each electrical identification product indicated.

Single-Family Dwelling Submittal Requirements

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW SINGLE-FAMILY DWELLING

Transcription:

LOS ANGELES WORLD AIRPORTS 07-18-2017

Contents 1 2 3 C Introduction... 04 06 S.1 Summary of Sign Types...04 S.2 Summary of Sign Types...05 1.1 Purpose...06 Wayfinding... 07 08 2.1 What is wayfinding...07 2.2 Influencing factors...08 2.3 Benefits of good wayfinding...08... 09 17 3.1 Signage Systems...09 3.2 Infrastructure Connectivity...10 3.3 Typography...12 3.4 Color Scheme...14 3.5 Pictograms...15 3.6 Pathway...17 C_Customs and Border Protection... 19 25 C_1 CBP Wall Identity...19 C_2 Welcome Identity...20 C_3 Carousel Identity...21 C_4 CBP Counter Identity...22 C_5 CBP Primary Checkpoint...23 C_6 Security Regulation...24 C_7 Hazmat regulation...25 02

Contents G R G_Gates... 26 31 R_Regulatory... 51 59 G_1 Pier Identity...26 R_1 Room Identity...51 G_2 Departure Hall Identity...27 R_2 Multiple Room Identity...52 G_3 Gate Identity...28 R_3 Defibrillator Room Identity...53 G_4 Gate Identity Sterile Corridor...29 R_4 Defibrillator Identity Vinyl...54 G_5 Counter Identity...30 R_5 General Services Identity...55 M G_6 TSA Identity Blade...31 M_Miscellaneous... 32 50 M_1 Room Occupancy...32 M_2 Life Safety Regulation Identity...33 M_3 Evacuation Plan Elevator...34 W R_6 Restroom Identity Door...56 R_7 Restroom Identity Wall...57 R_8 Restroom Identity No Door...58 R_9 General Services Identity Wall...59 W_Wayfinding... 60 76 M_4 Elevator Directory...35 W_1 CBP Identity Sign...60 M_5 Stairwell Identity...36 W_2 Pedestrian Directional - Smaller Overhead...61 M_6 Stair Identity...37 W_3 Pedestrian Directional - Overhead...62 M_7 Floor Identity...38 W_4 CBP Directional Static/Dynamic Overhead...63 M_8 Area of Assistance Sign...39 W_5 CSR Static Dynamic Overhead...64 M_9 Area of Evacuation Map/Stair Identity...40 W_6 Wall Identity...65 M_10 Tactile Exit - Wall...41 W_7 Pedestrian Directional - Smaller Overhead...66 M_11 Exit Only No Re-Entry...42 W_8 Small Directional - Wall...67 M_12 Restricted Area - Door...43 W_9 Wayfinding Directional - Wall...68 M_13 Poster Frame...44 W_10 Pedestrian Direction - Wall...69 M_14 Poster Stanchion...45 W_11 Informational Sign Placard...70 M_15 Poster Stanchion...46 W_12 Directional Sign Placard...71 M_16 Clearance Path...47 W_13 Small Freestanding Directional...72 M_17 Clearance Path - Wall...48 M_18 Clearance Bar...49 M_19 Clearance - Wall Mounted...50 W_14 Freestanding Directory...73 W_15 large Freestanding Directional...74 W_16 Freestanding Directional...75 M_20 Evacuation Plan Reduced Size...77 W_17 Pet Area Station...76 03

EXIT ONLY NO RE-ENTRY IN FIRE EMERGENCY, DO NOT USE ELEVATOR USE EXIT STAIRS LEVEL 3 RESTRICTED AREA TRESPASSING / LOITERING PROHIBITED BY LAW ALL AUTHORIZED PERSONNEL MUST DISPLAY ID BADGE BEYOND THIS POINT L.A.M.C. 56.30 L.A. CITY ORDINANCE NO. 95-789 FIRST CLASS BOARDING 5 U.S. CUSTOMS GENERAL BOARDING 4 RESTROOMS AUTHORIZED ACCESS ONLY 3 STAIR 5 NO ROOF ACCESS 1 THRU 5 IN CASE OF FIRE EVACUATION PLAN USE EXIT STAIRS 380 WORLD WAY - LEVEL 3 Stair 6 Stair 1 No Roof No Roof Access Access EVAC MAP TBD Pull Fire Alarm Use Stairs Emergency Phone Number: 911 Fire alarm is a flashing light Do Not Use Elevator with voice message You Are Here Fire Pull Exit Route Fire Extinguisher Elevator Area of Evacuation Stairwell Assistance Persons able to use stairway, do so as soon as possible. AREA FOR Emergency communications system EVACUATION is available 24 hours a day by using phone for assistance. ASSISTANCE 380 WORLD WAY - LEVEL 3 Stair 6 Stair 1 No Roof No Roof Access Access EVAC MAP TBD You Are Here Fire Pull FOR ASSISTANCE Exit Route Fire Extinguisher USE PHONE Elevator Area of Evacuation Stairwell Assistance EVACUATION PLAN 380 WORLD WAY - LEVEL 3 Stair 6 Stair 1 No Roof No Roof Access Access IN CASE OF FIRE USE EXIT STAIRS EVAC MAP TBD AREA FOR Emergency Phone Number: 911 EVACUATION Fire alarm is a flashing light with voice message ASSISTANCE You Are Here Fire Pull Exit Route Fire Extinguisher Pull Fire Alarm Elevator Area of Evacuation Use Stairs Stairwell Assistance Do Not Use Elevator EVACUATION PLAN IN CASE OF FIRE USE EXIT STAIRS DO NOT USE ELEVATOR 3/16 Stair 6 Stair 1 No Roof No Roof Access Access 3/16 EVAC MAP TBD YOU ARE HERE STAIRWELL AREA OF EVACUATION EXIT ROUTE FIRE PULL ASSISTANCE ELEVATOR FIRE EXTINGUISHER 380 WORLD WAY LEVEL 3 Emergency Phone Number: 911 Fire alarm is a flashing light with voice message Hazardous Materials There are special exceptions for small quantities (up to 70 ounces total) of medicinal and toilet articles carried in your luggage and certain smoking materials carried on your person. For further information contact your airline representative. S.1 Summary of Sign Types Federal law forbids the carriage of hazardous materials aboard aircraft in your luggage or on your person. A violation can result in five years' imprisonment and penalties of $250,000 or more (49 U.S.C. 5124). Hazardous materials include explosives, compressed gases, flammable liquids and solids, oxidizers, poisons, corrosives and radioactive materials. Examples: Paints, lighter fluid, fireworks, tear gases, oxygen bottles, and radio-pharmaceuticals. (TERMINAL IDENTITY) C_1 CBP WALL IDENTITY C_2 WELCOME IDENTITY C_3 BID/CAROUSEL ID C_4 CBP COUNTER IDENTITY C_5 CBP PRIMARY CHECKPOINT C_6 SECURITY REGULATION C_7 HAZMAT REGULATION Gate G_1 PIER IDENTITY G_2 DEPARTURE HALL IDENTITY G_3 GATE IDENTITY G_4 GATE IDENTITY STERILE CORRIDOR G_5 COUNTER IDENTITY G_6 TSA IDENTITY BLADE LEVEL 4 2 EXIT AT LEVEL 1 M_1 ROOM OCCUPANCY M_2 LIFE SAFETY REGULATORY IDENTITY M_3 EVACUATION PLAN ELEVATOR M_4 ELEVATOR DIRECTORY M_5 STAIRWELL IDENTITY M_6 STAIR IDENTITY M_7 FLOOR IDENTITY M_8 AREA OF ASSISTANCE SIGN M_9 AREA OF EVAC MAP/ STAIR IDENTITY M_10 EXIT ROUTE SPECIAL SERVICES KEEP CLEAR CAUTION KEEP AREA CLEAR AT ALL TIMES M_11 EXIT ONLY NO RE-ENTRY M_12 RESTRICTED AREA - DOOR M_13 POSTER FRAME M_14 POSTER STANCHION M_15 POSTER STANCHION M_16 CLEARANCE PATH M_17 CLEARANCE PATH WALL M_18 CLEARANCE BAR M_19 CLEARANCE - WALL MOUNT M_20 EVACUATION PLAN REDUCED SIZE 04

2-1-CR01 2-1-CR01 CBP TRAINING Mr. John Doe 0ffcr. Jane Doe Tom Bradley International Terminal Cell Phone Waiting Lot Airport Blvd. & Arbor Vitae St. 1 Long-Term Public Parking Lot C Free Bus S e r vice t o 3 Airline Terminals 2 1 Departure Upper Level Arrival Lower Level P-3 P-2 P-2A P-1 Center Way P-4 P-5 P-6 P-7 VP-6 Arrival Lower Level Departure Upper Level 4 5 6 7 8 Lot B 111th & La Cienega Blvd. Metro Rail Green Line Imperial Hwy. & Aviation Blvd. 105 1 VP-4 West Way Upper Level West Way Lower Level East Way Lower Level East Way Upper Level Sky Way Lincoln Blvd. epulve 96th St. Bridge W es t W. 96th St. W. 98th St. NORTH Airport Blvd. Long-Term Public Parking Lot B Free Bus Service t o Airline Terminals 405 405 111th St. Imperial Hwy Arbor Vitae St. Century Blvd. From I-405 Fwy. 104th St. La Cienega Blvd. Please pick-up after your pet. No Smoking. PLEASE CLEAN UP AFTER YOUR DOG! Summary of Sign Types S.2 R_1 ROOM IDENTITY R_2 MULTIPLE ROOM ID R_3 DEFIBRILATOR IDENTITY BLADE R_4 DEFIBRILATOR IDENTITY VINYL R_5 GENERAL SERVICES IDENTITY R_6 RESTROOM IDENTITY DOOR (TITLE 24) R_7 RESTROOM IDENTITY WALL R_8 RESTROOM IDENTITY NO DOOR R_9 GENERAL SERVICES IDENTITY - WALL Cashier Gates 130-144 Bag Claim Restrooms Restrooms Restaurants Customer Service Representative EXIT and Connecting Flights Elevators Ground Transport Restrooms Information Upper Boarding Bag Claim Restrooms Exit W_1 CBP IDENTITY W_2 PEDESTRIAN DIRECTIONAL - SMALLER OVERHEAD W_3 PEDESTRIAN DIRECTIONAL - OVERHEAD W_4 CBP DIRECTIONAL STATIC/DYNAMIC OVERHEAD W_5 CSR STATIC DYNAMIC OVERHEAD W_6 WALL IDENTITY W_7 PEDESTRIAN DIRECTIONAL - SMALL OVERHEAD W_8 SMALL DIRECTIONAL - WALL Gates 130-144 Restrooms Restaurants Gates 150-159 Gates 130-146 Gates 150-159 Gates 130-146 Gates 148 Lounge Rooms 00-00 Rooms 00-00 Gates 130-148 N. Concourse Airline Lounges Shopping Restrooms Concessions Gates Escalator Lounge Elevator Escalators Elevators Restrooms Restaurants Duty Free Lounges Escalators Elevators Restrooms Restaurants Duty Free Pet Relief Area Shopping S da Blvd. Restrooms Food W_9 WAYFINDING DIRECTIONAL - WALL W_10 PEDESTRIAN DIRECTIONAL - WALL W_11 INFORMATION SIGN PLACARD W_12 DIRECTIONAL SIGN PLACARD W_13 SMALL FREESTANDING DIRECTIONAL W_14 FREESTANDING DIRECTORY W_15 LARGE FREESTANDING DIRECTIONAL W_16 FREESTANDING DIRECTORY W_17 PET RELIEF STATION 05 07-18-2017

Introduction 1 INTRODUCTION The Standards includes information and advice on wayfinding practices as well as guidance on designing signs. It is intended to provide a reference and instruction on the important aspects of wayfinding as well as sources for more detailed and specific information. The use of the Standards should be taken into consideration in wayfinding planning activities throughout all terminals at LAX. Any variations to the guidelines should be presented to the proper department for approval. All signs in these standards are in compliance with the current ADA guidelines that regulates the size of symbols and accompanying text. To further aid the traveling public, LAWA emphasizes the use of international symbols on its wayfinding. TBIT West signs currently have smaller pictograms. Super graphics incorporating international symbols can be utilized as a wayfinding aid supplementing the existing signage to make the path of travel an intuitive experience. 1.1 Purpose 06 The for has been developed to assist the industry involved in delivering wayfinding information to travellers at Los Angeles International Airport. 08-04-2015

2 WAYFINDING 2.1 What is Wayfinding Wayfinding can be defined as a process in which people navigate an environment using information support systems such as architectural clues, lighting, sight lines and signage. Successful wayfinding systems can be measured by how travellers experience the airport environment and how the information facilitates self-navigation from point A to point B. Wayfinding systems should create a welcoming and enjoyable environment, reassure travellers and provide answers to questions before they have to ask for assistance. Wayfinding is achieved by focussing on the travellers needs, especially during the planning and design phases, and encompasses environmental factors, building design, user expectation and signage information. Wayfinding systems should provide the following information to travellers: identify their location reinforce they are travelling in the right direction identify their destination on arrival (of each area) know where to exit safely in an emergency 07 Wayfinding Wayfinding information can be delivered through the following: dynamic information static signs temporary information lighting building design user s prior knowledge and experience staff audible information 08-04-2015

2.2 Influencing Factors 2.3 Benefits of Good Wayfinding 08 Wayfinding HUMAN These are the factors concerned with the individual and their ability to interpret wayfinding information being conveyed to them. This is influenced by their experience in the airport environment and their familiarity with the type of information they encounter. Inexperienced travellers tend not to have a good understanding of how to move through an airport and will look for more information. When a person is unable to locate the information they require, they will seek alternative sources such as asking staff. People are unable to store a lot of information in their short term memory and they may ignore important information when they are unable to distinguish it from other less relevant information. INFORMATION The type of information provided to travellers (visual, audible or physical) and how they interpret and understand this information will affect how they find their way through the airport. Travellers need consistent, concise, accurate and timely information when they are in the airport environment. If a traveller is unable to find their way it can lead to frustration and a poor experience. Good wayfinding can offer a number of benefits, including: traveller satisfaction reduce clutter and unnecessary information in the airport environment aid traveller flow and reduce airport crowding assist travellers get to their flights on time allows travellers to reach their destination easily and quickly, allowing them time to explore their environment (e.g. shopping, eating, relaxing) reduce enquiries to airport staff Wayfinding information that is similar to other airport information may be confusing and should be avoided wherever possible. Travellers should be able to distinguish wayfinding information from other types of information, such as operational or advertising. ENVIRONMENT An airport s physical layout and architectural features will also influence successful wayfinding. Providing information and reassurance at decision points will help travellers make decisions. The use of sight lines and other visual clues will also aid wayfinding. 08-04-2015

3 SIGNAGE DESIGN GUIDE 3.1 Signage Systems The primary purpose of an airport sign system is to move travellers through the airport using a concise and comprehensive system of directional, operational, informational and regulatory messages. The following are sign design guidelines for use at all of the Los Angeles International Airport terminals. Signs should be positioned to ensure consistency, visual clutter is reduced and travellers are presented with key information at critical decision making points. Avoid positioning several contrasting signs in close proximity to each other. Signs and posters should not compete with other signs for the user s visual attention. Provide travellers with key information at critical decision making points. To support decision making, travellers need clear directions at decision points. 09 08-04-2015

3.2 Infrastructure Connectivity GENERAL REQUIREMENTS FOR INFRASTRUCTURE Admonition to Environmental Graphics Designers When working for (LAWA), designers must adhere to the following procedures during the design phases of all signage projects. All submittals shall conform to the design direction set forth in this design manual. The sign fabricator will review all types of signs, messages, and graphics that are indicated on the design drawings and specifications, and confirm various materials, finishes, electrical and data requirements. The structural design and calculations for all signage will require certification by an Engineer licensed in the State of California. The fabricator will complete the structural design of the signs and coordinate with the engineer and/or general contractor for infrastructure connections. It is expected and required that all environmental graphics designers participating in any graphics/signage projects with LAWA ensure that all work associated with the fabrication and installation of the signage maintain its aesthetic integrity. Engineering services must be retained for the purpose of graphics/ signage construction in order for documentation to be complete and thorough. This documentation includes, but is not limited to structural, electrical, data, and any other engineering services required for the successful implementation of the graphics/signage program. Submittal documents (shop drawings) shall be complete in application, size, details, materials and specifications and reflect the sign types and designs described in this manual. The Engineering team will coordinate with the sign fabricator and the general contractor on all infrastructure footings, structural attachments, and penetrations of slabs in new and existing building conditions. It shall be the responsibility of the engineering/fabricating team to perform the complete review of the sign s infrastructure connections and to incorporate all the reasonable safety factors necessary to protect the Owner and their representatives, against public liability. All electrical and data requirements shall be identified by an electrical engineer, licensed in the State of California and will provide all panel to install locations specifications and circuitry information. 10 03-07-2017

Infrastructure Connectivity Details 3.2 RESTORE FIREPROOFING OF STEEL BEAM STEEL STRUCTURE V.I.F. RESTORE FIREPROOFING OF STEEL BEAM RESTORE FIREPROOFING OF STEEL BEAM VERIFY CEILING CONNECTION CONFIGURATION OPTIONS A SECTION DETAIL B SECTION DETAIL C SECTION DETAIL ESCUTCHEON COVER MOUNTING PLATE SIGN CABINET D SECTION DETAIL MOUNTING HARDWARE AS REQUIRED FACILITY WALL (VERIFY) BLOCKING AS REQUIRED WALL CONNECTION CONFIGURATION OPTIONS SIGN CABINET INTERNAL J-BOX SIGN CABINET SIGN CABINET BASE PLATE ELECTRICAL AND DATA FEEDS ANCHOR AS REQUIRED BASE PLATE ANCHOR AS REQUIRED FINISHED FLOOR FINISHED FLOOR SLAB THICKENED SLAB E SECTION DETAIL F SECTION DETAIL ELECTRICAL AND DATA CONDUIT AS REQ D FLOOR CONNECTION CONFIGURATION OPTIONS 11 03-07-2017

3.3 Typography Helvetica Neue Lt Pro 65 Medium Helvetica Neue Lt Pro 75 Bold 12 08-04-2015

Typography 3.3 Franklin Gothic ITC BY BT Demi Joanna MT Semibold Regular 13 08-04-2015

3.4 Color Scheme Paint NOTE: CONTRACTED GRAPHICS DESIGNER IS TO PROVIDE TERMINAL SPECIFIC COLORS WITH PAINT SPECIFICATIONS FOR EACH SIGNAGE PACKAGE FOR REVIEW AND APPROVAL. DESIGNER TO PROVIDE THREE(3) PAINT SAMPLES OF EACH COLOR PROPOSED. MINIMUM SIZE FOR COLOR SAMPLES IS 3 X3. Materials NOTE: CONTRACTED GRAPHICS DESIGNER IS TO PROVIDE TERMINAL SPECIFIC MATERIALS WITH SPECIFICATIONS FOR EACH SIGNAGE PACKAGE FOR REVIEW AND APPROVAL. DESIGNER TO PROVIDE THREE(3) PAINT SAMPLES OF EACH FINISH AND MATERIAL PROPOSED. MINIMUM SIZE FOR SAMPLES IS 6 X6. 14 03-07-2017

Pictograms 3.5 Terminal RESTROOM MEN RESTROOM WOMEN RESTROOM ALL GENDER RESTROOM CHANGING ROOM NURSING ROOM ELEVATOR ACCESSIBLE ELEVATOR STAIRS ESCALATOR WAITING ROOM LITTER DISPOSAL ATM SHOPS RESTAURANT FOOD DRINKING FOUNTAIN WATER DISPENSER CASHIER CURRENCY EXCHANGE TICKET PURCHASE PUBLIC PHONE COURTESY PHONE NO SMOKING SMOKING ANIMAL CARE PET AREA (EXTERNAL USE) PET AREA (INTERNAL USE) COMPUTER STATION VENDING MACHINES PLAY AREA BAGGAGE BUSINESS CENTER PARKING NO ENTRY INFORMATION CLEAN AIR COFFEE SHOP FORWARD AND LEFT ARROW FORWARD AND RIGHT ARROW LEFT AND DOWN ARROW RIGHT AND DOWN ARROW UP ARROW RIGHT ARROW LEFT ARROW DOWN ARROW U-TURN ARROW 15

3.5 Pictograms Roadway TAXI GROUND TRANSPORT CAR RENTAL LAX TRANSPORTATION BUS GATES CONNECTING FLIGHT DEPARTING FLIGHTS ARRIVING FLIGHTS International Travel CUSTOMS AGRICULTURE IMMIGRATION Accessible ACCESSIBLE TTY HEARING LOSS VOLUMN CONTROL TELEPHONE Emergency FIRST AID DEFIBRILLATOR INFORMATION EXIT * Where pictograms are provided as designations of permanent interior rooms and spaces, they shall comply with requirements for minimum field height, finish and contrast, and they shall be accompanied by compliant tactile (raised letter and braille) descriptors. Directional and informational pictograms are not required to have tactile descriptors. 16 07-18-2017

Pathway 3.6 Orientation & Interpretation APPLICATION/ ORIENTATION LOCATION PLAN INTERPRETATION APPLICATION/ ORIENTATION LOCATION PLAN INTERPRETATION STRAIGHT AHEAD RIGHT UP DOWN ON RIGHT AHEAD ON LEFT LEFT UP ON LEFT DOWN ON LEFT AHEAD ON RIGHT DOWN UP ON RIGHT 17

3.6 Pathway Decision Point Diagram Terminal 3 example Minimum font heights when viewed from distance: 20-3 25-3 3/4 30-4 1/2 Concourse South Concourse North 22'-0" +- viewing distance Point or approach area where passenger must make a directional decision Sign Decision point Sight line Circulation path 18

CBP Wall Identity C_1 CBP Signage Contact Information NOTE: CBP SIGNAGE MAY BE REQUIRED IN THE TERMINALS. CONTACT THE FOLLOWING FOR DETAILED SIGNAGE INFORMATION AND STANDARDS. CUSTOMS & BORDER PROTECTION GENERAL PRINTING & GRAPHICS (202) 344-1310 CUSTOMS & BORDER PROTECTION MISSION SUPPORT (562) 980-3140 ext.102 19 08-04-2015

C_2 Welcome Identity 1. FABRICATED ALUMINUM LETTERFORMS AND LOGO. 2. LETTER FACES AND RULE LINES TO BE VERTICAL BRUSHED FINISH WITH MIRROR POLISHED RETURNS. 3. 3 THICK LETTERFORMS AND RULE TO BE PIN MOUNTED 1/2 FROM FACILITY WALL WITH THREADED WELDED STUDS, PAINTED NON-CORROSIVE SPACERS AND EPOXY ADHESIVE. 4. VERIFY WALL CONSTRUCTION PRIOR TO FABRICATION OF SIGN. 5. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND LOCATION OF SIGN TO BE PROVIDED BY LAWA. REFER TO NOTE FROM SIGN TYPE C_1 CONTEXT ELEVATION 3 NOT TO SCALE 1 1/8" 11 11 20 08-04-2015

Carousel Identity C_3 1. DOUBLE SIDED SIGN CABINET WITH LCD DISPLAYS. 2. SIGN CABINET TO HAVE INTERNAL FRAMING AND CLADDED WITH BRUSHED ALUMINUM. PROVIDE INCONSPICUOUS ACCESS AS REQUIRED FOR EASE OF MAINTENANCE. EXPOSED EDGES OF ALUMINUM TO BE POLISHED. 3. FABRICATED ALUMINUM SIGN PANEL PAINTED IN COLOR NOTED. 4. NUMERALS TO BE FLAT-CUT-OUT ALUMINUM WITH PAINT FINISH AS NOTED. ADHERE TO SIGN PANEL WITH HIDDEN MECHANICAL FASTENERS. SIGN CABINET 2. SIGN PANEL 3. 5. LCD ARRAY DYNAMIC DISPLAY SCREENS TO BE PROVIDED BY LAWA/GC (EXAMPLE: NEC P701 70 - USE CURRENT SPECIFICATION). INSTALL INTO SIGN CABINET IN A MANNER TO ALLOW EASE OF MAINTENANCE. MONITORS TO BE LOCKED INTO PLACE. COORDINATE WITH LAWA/GC FOR DISPLAY REQUIREMENTS. WEIGHT OF MONITORS IS APPROXIMATELY 220 LBS EACH. PROVIDE APPROPRIATE STRUCTURAL SUPPORT AS REQUIRED BY STRUCTURAL ENGINEERING CALCULATIONS. DETAIL SHOWN IS ONLY A SUGGESTION. SECTION DETAIL 5 NOT TO SCALE 6. FINAL MESSAGE PER SIGN LOCATION TO BE PROVIDED BY LAWA. 7. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLATION. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS. 8. TOTAL APPROXIMATE WEIGHT: 850 LBS. TOTAL APPROXIMATE WATTAGE REQUIREMENT: 1500W 9. SIGN CABINET BASE TO BE CLADDED WITH BRUSH FINISHED ALUMINUM. NOTE: ALL TEXT MUST COMPLY WITH THE ADA STANDARDS, INCLUDING FONT SIZE, COLOR CONTRAST AND READABILITY FROM A DISTANCE. TOP ELEVATION 4 NOT TO SCALE HINGED DOOR ASSEMBLY MONITOR 5 TBD 1 NOT TO SCALE SIDE ELEVATION 2 NOT TO SCALE 21

C_4 CBP Counter Identity 1. NON-ILLUMINATED IDENTIFICATION NUMBER PLAQUES AND APPLIED VINYL LOGOS. 1. NON-ILLUMINATED IDENTIFICATION NUMBER PLAQUES AND APPLIED VINYL LOGOS. 2. SIGN PANEL BACKGROUND TO BE ALUMINUM WITH BRUSHED FINISH. 2. SIGN PANEL BACKGROUND TO BE ALUMINUM WITH BRUSHED FINISH. 3. SIGN PANEL TO BE PAINTED ALUMINUM PERMANENTLY ATTACHED TO SIGN BACKGROUND. 3. SIGN PANEL TO BE PAINTED ALUMINUM PERMANENTLY ATTACHED TO SIGN BACKGROUND. 4. NUMERALS TO BE FLAT-CUT-OUT PAINTED ALUMINUM AND APPLIED TO SIGN PANEL WITH ALIGNMENT PINS AND 4. ADHESIVE NUMERALS AS REQUIRED. TO BE FLAT-CUT-OUT PAINTED 1/8 ALUMINUM AND APPLIED TO SIGN PANEL WITH ALIGNMENT PINS AND ADHESIVE AS REQUIRED. 5. GRAPHIC LOGOS (WHERE OCCURS) TO BE APPLIED VINYL. GLOBAL ENTRY LOGO TO FOLLOW CBP GUIDELINES. 5. REFER GRAPHIC TO LOGOS CBP.GOV (WHERE FOR INFORMATION. OCCURS) TO BE APPLIED VINYL. GLOBAL ENTRY LAWA TO PROVIDE SPECIFIC LOGO LOCATIONS. LOGO TO FOLLOW CBP GUIDELINES. REFER TO CBP.GOV FOR INFORMATION. LAWA TO PROVIDE SPECIFIC LOGO LOCATIONS. 6. SIGN TO BE MOUNTED TO PODIUM WITH THREADED WELDED STUDS AND SILICONE ADHESIVE AS REQUIRED. 6. SIGN TO BE MOUNTED TO PODIUM WITH THREADED WELDED STUDS AND SILICONE ADHESIVE AS REQUIRED. 7. FINAL MESSAGE PER SIGN LOCATION TO BE PROVIDED BY LAWA. 7. FINAL MESSAGE PER SIGN LOCATION TO BE PROVIDED BY LAWA. CONTEXT ELEVATION CONTEXT ELEVATION 3 SCALE: 3/16 = 1-0 3 SCALE: 3/16 = 1-0 SIGN BACKGROUND SIGN PANEL 3. NUMERALS 4. SIGN BACKGROUND 2 SIGN PANEL 3 NUMERALS 4 2 NOT TO SCALE 1/8 1/8 1/8 DETAIL PLAN VIEW DETAIL PLAN VIEW 2 SCALE: 1 1/2 -= 1-0 1/8 1/8 1/8 GLOBAL ENTRY LOGO 5. GLOBAL ENTRY LOGO 5. 22 1 NOT TO SCALE 1 SCALE: 1 1/2 = 1-0 SIGN BACKGROUND SIGN PANEL 3. SIGN BACKGROUND NUMERALS 4. SIGN PANEL 3 PODIUM 6. NUMERALS 4 PODIUM 6 C_2 - CUSTOMS CHECKPOINT IDENTITY

CBP Primary Checkpoint C_5 4'-0" 1. CEILING MOUNTED DISPLAY MONITOR INCASED IN A FABRICATED ALUMINUM CABINET WITH INTERNAL ILLUMINATION FOR NUMERALS, ARROWS, AND RED/GREEN LIGHTING. PLAN 2'-11 1'-3" 1-0" 2. MONITOR TO BE NEC 40 #P401 AND SUPPLIED BY OWNER. PROVIDE AND INSTALL MOUNTING BRACKET AS REQUIRED BY STRUCTURAL ENGINEERING CALCULATIONS. 3. CABINET AND SHROUD TO BE FABRICATED WITH BRUSHED ALUMINUM AND HAVE INTERNAL FRAMING AS REQUIRED. PROVIDE INCONSPICUOUS ACCESS PANELS FOR MAINTENANCE. C_4 2'-0" 1'-7 ELEVATION OPTIONAL CONFIGURATION 3 SCALE: 1/2 = 1-0 3 3/8" SIDE 6 CBP Primary Checkpoint 6'-8" MIN. VERIFY STRUCTURE ABOVE 7 8 5. INTERNAL ILLUMINATION TO BE WHITE LED. 6. RED/GREEN LIGHTS TO BE PUSH-THRU TRANSLUCENT WHITE ACRYLIC AND INTERNALLY ILLUMINATED WITH INDEPENDANTLY CONTROLLED RED AND GREEN LED LIGHTING. SURFACE OF PUSH-THRU LENS TO BE FLUSH WITH CABINET SURFACE. PROVIDE 3 SETTINGS PER LENS, RED, GREEN AND OFF. 7. PRIOR TO BID SUBMISSION, VERIFY FACILITY STRUCTURE PRIOR TO SIGNAGE FABRICATION. PROVIDE MOUNTING BRACKET AS REQUIRED BY STRUCTURAL ENGINEERING CALCULATIONS. 8. PRIOR TO BID SUBMISSION, COORDINATE STRUCTURAL, ELECTRICAL AND DATA REQUIREMENTS WITH GENERAL CONTRACTOR. 9. LAWA TO PROVIDE SPECIFIC MESSAGING PER SIGN LOCATION. Signage Details Sheet SD_04 NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. 7 8 Location Above checkpoint kiosks Dimensions Cabinet: MASKED 3-5 AND PAINTED FIELD x 2-10 Screen: 2-11 x 1-8 VINYL GRAPHICS 7 8 8 ALL TEXT MUJST COMPLY WITH ADA STANDARDS INCLUDING TEXT HEIGHT, COLOR CONTRAST AND READABILITY FROM A DISTANCE AND ILLUMINATION. 1 SCALE: 1 = 1-0 SECTION 2 SCALE: 1 = 1-0 23

Airport operators, in consultation with their FSD, must develop and incorporate into their TSA-approved ASP, Aviation Security (AVSEC) Contingency Plans that are tailored to the airport. AVSEC systems, methods and procedures should address specific HSAS levels. In developing the plan, the airport operator and FSD must consider the relative risk to the airport, existing vulnerabilities identified through a vulnerability assessment of the airport, unique characteristics of the airport, and resources available to the airport.when the Secretary of the Department of Homeland Security declares the nation at an enhanced threat condition, the airport operator and others must immediately implement the corresponding security measures contained in the AVSEC Contingency Plan and all appropriate security directives. In addition, the airport operator is responsible to ensure that an FAA-approved Airport Emergency Plan (AEP), is coordinated with the TSA FSD and included in the overall Airport Operations Manual for FAA certification of the airport. The AEP will identify the local emergency response agencies (hospitals, emergency medical services, mutual-aid first responders, military and federal support agencies, etc.) and types of services which will need to be accommodated and may require additional facilities during emergency conditions. Airport operators, in consultation with their FSD, must develop and incorporate into their TSA-approved ASP, Aviation Security (AVSEC) Contingency Plans that are tailored to the airport. AVSEC systems, methods and procedures should address specific HSAS levels. developing the plan, the airport operator and FSD must consider the relative risk to the airport, existing vulnerabilities identified through a vulnerability assessment of the airport, unique characteristics of the airport, and resources available to the airport.when the Secretary of the Department of Homeland Security declares the nation at an enhanced threat condition, the airport operator and others must immediately implement the corresponding security measures contained in the AVSEC Contingency Plan and all appropriate security directives. In C_6 Security Regulation US DEPARTMENT OF HOMELAND SECURITY RULES AND REGULATIONS Airport operators, in consultation with their FSD, must develop and incorporate into their TSA-approved ASP, Aviation Security (AVSEC) Contingency Plans that are tailored to the airport. AVSEC systems, methods and procedures should address specific HSAS levels. In developing the plan, the airport operator and FSD must consider the relative risk to the airport, existing vulnerabilities identified through a vulnerability assessment of the airport, unique characteristics of the airport, and resources available to the airport.when the Secretary of the Department of Homeland Security declares the nation at an enhanced threat condition, the airport operator and others must immediately implement the corresponding security measures contained in the AVSEC Contingency Plan and all appropriate security directives. 1. 1/8 THICK WHITE SINTRA PANEL WITH SCREENED GRAPHICS. In addition, the airport operator is responsible to ensure that an FAA-approved Airport Emergency Plan (AEP), is coordinated with the TSA FSD and included in the overall Airport Operations Manual for FAA certification of the airport. The AEP will identify the local emergency response agencies (hospitals, emergency medical services, mutual-aid first responders, military and federal support agencies, etc.) and types of services which will need to be accommodated and may require additional facilities during emergency conditions. Airport operators, in consultation with their FSD, must develop and incorporate into their TSA-approved ASP, Aviation Security (AVSEC) Contingency Plans that are tailored to the airport. AVSEC systems, methods and procedures should address specific HSAS levels. In developing the plan, the airport operator and FSD must consider the relative risk to the airport, existing vulnerabilities identified through a vulnerability assessment of the airport, unique characteristics of the airport, and resources available to the airport.when the Secretary of the Department of Homeland Security declares the nation at an enhanced threat condition, the airport operator and others must immediately implement the corresponding security measures contained in the AVSEC Contingency Plan and all appropriate security directives. US DEPARTMENT OF HOMELAND SECURITY RULES AND REGULATIONS 2. MOUNT TO WALL WITH SILICONE ADHESIVE AND DOUBLE-SIDED TAPE. 3. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. OBTAIN MESSAGE AND SIGNAGE CRITERIA FROM LAWA. 1-3 10 9 1/8 CL 5/16" 5/16" 1/8" 1'-10" MOUNT WITH SILICONE ADHESIVE AND DLUBLE-SIDED TAPE 24 SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE

Hazmat Regulation C_7 Hazardous Materials Federal law forbids the carriage of hazardous materials aboard aircraft in your luggage or on your person. A violation can result in five years' imprisonment and penalties of $250,000 or more (49 U.S.C. 5124). Hazardous materials include explosives, compressed gases, flammable liquids and solids, oxidizers, poisons, corrosives and radioactive materials. Examples: Paints, lighter fluid, fireworks, tear gases, oxygen bottles, and radio-pharmaceuticals. There are special exceptions for small quantities (up to 70 ounces total) of medicinal and toilet articles carried in your luggage and certain smoking materials carried on your person. For further information contact your airline representative. 1. 1/8 THICK WHITE SINTRA PANEL WITH SCREENED GRAPHICS. 2. MOUNT TO WALL WITH SILICONE ADHESIVE AND DOUBLE-SIDED TAPE. 3. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. OBTAIN MESSAGE AND SIGNAGE CRITERIA FROM LAWA. NOTE: ALL TEXT MUST COMPLY WITH THE ADA STANDARDS, INCLUDING FONT SIZE, COLOR CONTRAST AND READABILITY. 1 1/8 3" 2 7/8" 3/18" 1'-5 MOUNT WITH SILICONE ADHESIVE AND DLUBLE-SIDED TAPE 1'-2 1/4 SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 25

G_1 Pier Identity G_1 Location Pier Identity M_3 AED Identity Location Dimensions 3'-0" Dimensions 2'-0" 4'-0" 26 SECTION DETAIL 1 NOT TO SCALE SECTION DETAIL 2 NOT TO SCALE

Departure Hall Identity G_2 1. NON-ILLUMINATED, DIMENSIONAL LETTERING MOUNTED TO WALL. 2. FABRICATED ALUMINUM LETTERS WITH PAINTED FINISH. 3. MESSAGE, SIZE, AND LOCATION TO BE DETERMINED BY LAWA. 4. FONT: HELVETICA NEUE LT PRO 85 HEAVY 1 NOT TO SCALE 27 08-04-2015

G_3 Gate Identity 1'- 1 C L 1. DOUBLE-FACED, NON ILLUMINATED, FREESTANDING PYLON SIGN WITH DIMENSIONAL COPY. 2. FABRICATED ALUMINUM CABINET WITH INTERNAL STRUCTURE AS REQUIRED. 3 2 2 COPY 4. 6. COPY 4. 6. 3. SIGN PANELS TO BE FABRICATED ALUMINUM PAINTED IN COLOR INDICATED. ATTACH TO SIGN CABINET IN AN INCONSPICUOUS MANNER. 4. COPY TO BE FLAT-CUT-OUT PAINTED ALUMINUM FLUSH MOUNTED TO SIGN PANEL WITH HIDDEN MECHANICAL FASTENERS. FACE AND EDGES OF COPY TO BE PAINTED IN COLOR INDICATED. 5. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLATION. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR FOOTING REQUIREMENTS. 6. LAWA TO PROVIDE SPECIFIC MESSAGES PER SIGN LOCATION. 8" 9'-0" 8'-4" Gate 8" FOOTING 5. SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 28

Gate Identity Sterile Corridor G_4 CEILING 1. NON-ILLUMINATED SIGN PANEL WITH MOUNTING BRACKET. 2. BACKGROUND PANEL TO BE 1/2 ALUMINUM INTEGRATED WITH MOUNTING BRACKET AS REQUIRED. 3. SIGN PANEL TO BE 1/8 THICK PAINTED ALUMINUM PANEL IN COLOR INDICAT- ED. ATTACH TO BACKGROUND PANEL IN A PERMANENT MANNER. 6'-8" MIN. AFF 4. GRAPHICS TO BE 1/4 THICK FLAT CUT OUT PAINTED ALUMINUM ADHERED TO SIGN PANEL WITH EPOXY AND ALIGNMENT PINS OR HIDDEN FASTENERS. 5. ALUMINUM MOUNTING BRACKET WITH WELDED CONSTRUCTION AS REQUIRED. ATTACH TO CEILING WITH FLAT-HEAD/COUNTERSUNK FASTENERS AS REQUIRED. 6. FIELD VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGNS. COORDINATE WITH G.C. AND DETERMINE BEST METHOD FOR INSTALLATION REQUIREMENTS. FINISHED FLOOR 7. LAWA TO PROVIDE SIGN LOCATIONS AND SPECIFIC MESSAGE PER SIGN LOCATION. 8. A MINIMUM VERTICAL CLEARANCE OF 6-8 AFF ON ELEVATION. 1'-6" 1'-4" 1 BLOCKING 6. MOUNTING BRACKET 5. 3" GRAPHICS 4 1'-6" 1'-4" 6" BACKGROUND PANEL 2. SIGN PANEL 3. SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 29

G_5 Counter Identity 1. FABRICATED ALUMINUM NUMBERS. TV DISPLAY TV Y 2. NUMBERS TO BE FABRICATED ALUMIUM WITH ALL SURFACES PAINTED IN COLOR NOTED. NUMBERS TO BE MOUNTED TO 3/16 THICK ALUMINUM BASE PLATE. 3. ATTACH SIGNAGE TO FACILITY GATE PODIUM WITH COUNTERSUNK MECHANI- CAL FASTENERS AS REQUIRED. 4. FIELD VERIFY EXISTING CONDITIONS. COORDINATE WITH GENERAL CONTRAC- TOR TO DETERMINE BEST METHOD OF INSTALLATION BASED ON STRUCTURAL ENGINEERING CALCULATIONS. 5. LAWA TO PROVIDE LOCATIONS AND SPECIFIC MESSAGES PER SIGN LOCATION. 6. A MINIMUM VERTICAL CLEARANCE OF 6-8 AFF ON ELEVATION. 6'-8" MIN. AFF FINISHED FLOOR 30 08-04-2015 SECTION DETAIL 1 SCALE: 1 1/2 -= 1-0 2 SCALE: 3 -= 1-0

TSA Identity Blade G_6 9" 2" PYLON 2 M1 1. FREESTANDING, NON-ILLUMINATED, DOUBLE-FACED FABRICATED PYLON IDENTITY. 2. PYLON TO BE FABRICATED ALUMINUM CONSTRUCTION WITH BRUSHED FINISH. 10 4 2" 1 NUMBERS 4 P2 SIGN PANEL 3 P1 3. SIGN PANEL TO BE 1/8 THICK PAINTED ALUMINUM PANEL PERMANENTLY ADHERED TO PYLON. 4. NUMBER TO BE FLAT-CUT-OUT 22 GUAGE ALUMINUM WITH FACE AND EDGES PAINTED IN COLOR NOTED. RULE LINE 5 P5 5. RULE LINE TO BE MASKED AND SPRAY PAINTED OR SCREEN PRINTED. 6. FIELD VERIFY EXISTING CONDITIONS. COORDINATE WITH GENERAL CONTRACTOR TO DETERMINE BEST METHOD OF INSTALLATION BASED ON STRUCTURAL ENGINEERING CALCULATIONS. 7. LAWA TO PROVIDE LOCATIONS AND SPECIFIC MESSAGES PER SIGN LOCATION. 8. LAWA TO PROVIDE OVERALL SIGNAGE DIMENSIONS. 6'-10" 5'-11 1 NOT TO SCALE 31

MAXIMUM OCCUPANCY NOT TO EXCEED M_1 Room Occupancy C L 75 PERSONS 5'-6" 5'-0" 1. WALL MOUNTED PLAQUE WITH PAINTED BACKGROUND AND SCREENED GRAPHICS. 2. SIGN PANEL TO BE 1/8 THICK BRUSHED ALUMINUM WITH MASKED AND PAINTED BACKGROUND. 3. COPY TO BE 3M MATTE WHITE OPAQUE FILM MACHINE CUT VINYL AS INDICATED ON DRAWING. 4. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND VHB TAPE AS REQUIRED. 5. LAWA TO PROVIDE SPECIFIC MESSAGE PER LOCATION OF SIGN. CONTEXT ELEVATION 3 NOT TO SCALE 10" 9 C L OF SIGN & COPY 10" 9 C L 2 3" 4 SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 32

Life Safety Regulation Identity M_2 1. 2. 3. 1/8 THICK STAINLESS STEEL PANEL WITH SCREENPRINTED GRAPHICS. INLAYED 1/32 D. DIMENSIONAL LETTERS TO BE 1/16 THICK PAINTED AS NOTED. MOUNT TO WALL WITH SPACER PANEL (THICKNESS DETERMINED BY EXISITING CALL BUTTON PANEL), VHB TAPE AND SILICONE ADHESIVE. 4. 5. BRAILLE TO BE GRADE 2 STAINLESS STEEL BEADS. REFER TO MESSAGE SCHEDULE FOR EXACT MESSAGE PER LOCATION OF SIGN. Jambs of Elevator Hoistway Entrance 6. WIDTH IS DETERMINED BY WIDTH OF ELEVATOR CALL BUTTON PANEL. CONFIRM PRIOR TO FABRICATION OF SIGN. CONTEXT ELEVATION 3 NOT TO SCALE 7. FIELD VERIFY PRIOR TO FABRICATION. NOTE: THIS SIGN IS NOT REQUIRED, NOR SHOULD IT BE PROVIDED AT ELEVATORS THAT SERVE AS AN ACCESSIBLE MEANS OF EGRESS (CBC 3002.3, EXCEPTION 1), OR AT ELEVATORS THAT ARE USED FOR OCCUPANT SELF-EVACUATION IN ACCORDANCE WITH CBC 3008 (CBC 3002.3, EXCEPTION 2). 5"± VERIFY C L C L 11/16" 4 3/8" 3 PICTOGRAM FIELD 1 2" 3 3/8" 9" 5/16" 3/16" 5/16" 3/16" 5/16" 3/16" 5/16" 3/16" 5/16" IN FIRE EMERGENCY, DO NOT USE ELEVATOR USE EXIT STAIRS ELEVATOR HOISTWAY SIGN 2 1/8" 1 NOT TO SCALE SIDE ELEVATION 2 NOT TO SCALE 33

EVACUATION PLAN IN CASE OF FIRE USE EXIT STAIRS DO NOT USE ELEVATOR 3/16 Stair 6 Stair 1 No Roof No Roof Access Access 3/16 EVAC MAP TBD YOU ARE HERE STAIRWELL AREA OF EVACUATION EXIT ROUTE FIRE PULL ASSISTANCE ELEVATOR FIRE EXTINGUISHER 380 WORLD WAY LEVEL 3 Emergency Phone Number: 911 Fire alarm is a flashing light with voice message M_3 Evacuation Plan Elevator 1. EVACUATION PLAN REGULATION SIGNAGE. 2. SIGN BACKGROUND TO BE 1/8 THICK ALUMINUM WITH BRUSHED FINISH ON FACE AND EDGES. RECOMMENDED HEIGHT 3. 1/8 THICK PAINTED ACRYLIC SIGN PANEL TO BE ADHERED TO SIGN BACKGROUND IN A PERMANENT MANNER. 4. ALL COPY AND GRAPHICS TO BE SCREEN PRINTED IN COLORS INDICATED. 5. FLUSH MOUNT TO EXISTING WALL WITH WELDED THREADED STUDS AND SILICONE ADHESIVE AS REQURIED. 6. LAWA TO PROVIDE BASE MAP ART AND SPECIFIC MESSAGES PER LOCATION OF SIGN. CONTEXT ELEVATION 3 NOT TO SCALE 11 5/8 9/16 COPY P2 4 C L OF SIGN & COPY 1/4 1/4 3/8 5/8 1/4 3/8 1/4 3/8 EVACUATION PLAN IN CASE OF FIRE USE EXIT STAIRS DO NOT USE ELEVATOR 3/16 PICTOGRAM PICTOGRAM P5 P2 4 4 Stair 6 No Roof Access Stair 1 No Roof Access PICTOGRAM P2 SIGN BACKGROUND PANEL SIGN PANEL 3 P1 2 M1 1-2 PICTOGRAM P4 3/16 EVAC MAP TBD PICTOGRAM P5 4 PICTOGRAM BACKGROUND P2 EVAC MAP TBD Key Plan 34 1/4 3/16 3/8 3/16 3/8 3/16 1/4 5/8 3/8 1/4 3/4 1/4 3/8 1/4 3/8 3/8 1/4 1 NOT TO SCALE PICTOGRAM P1 4 PICTOGRAM BACKGROUND PICTOGRAM P5 4 PICTOGRAM BACKGROUND RULE P2 4 COPY P2 4 NUMBERS P5 4 P2 P2 SIDE ELEVATION 2 NOT TO SCALE YOU ARE HERE EXIT ROUTE ELEVATOR 380 WORLD WAY LEVEL 3 STAIRWELL FIRE PULL FIRE EXTINGUISHER AREA OF EVACUATION ASSISTANCE Emergency Phone Number: 911 Fire alarm is a flashing light with voice message

Elevator Directory M_4 1. WALL MOUNTED PLAQUE WITH PAINTED BACKGROUND AND SCREENED GRAPHICS. 2. SIGN PANEL TO BE 1/8 THICK BRUSHED ALUMINUM WITH MASKED AND PAINTED BACKGROUND. 3. COPY AND GRAPHICS TO BE MACHINE CUT VINYL ON INDIVIDUAL CHANGEABLE PANELS WITH COLOR TO MATCH AS INDICATED ON DRAWING. 4. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND VHB TAPE AS REQUIRED. 5. LAWA TO PROVIDE SPECIFIC MESSAGE PER LOCATION OF SIGN. 1'-8" 4 1/8" 2 7/8" 2 7/8" 2 7/8" 3" 9/16" 1 9/16" 9/16" 11/16" 3/8" 11/16" 9/16" 1 3/32" 11/16" 1 3/32" LEVEL 4 5 4 3 FIRST CLASS BOARDING U.S. CUSTOMS GENERAL BOARDING RESTROOMS AUTHORIZED ACCESS ONLY 5'-10" MAX LEVEL 4 5 FIRST CLASS BOARDING U.S. CUSTOMS GENERAL BOARDING 4 RESTROOMS 3 AUTHORIZED ACCESS ONLY 2 7/8" 2 7/8" SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 35

M_5 Stairwell Identity TOP OF SIGN 1. ADA AND LOCAL FIRE CODE COMPLIANT WALL MOUNTED IDENTIFICATION PANEL. 2. BACKGROUND PANEL TO BE 4MM SINTRA FINISH ON FACE AND EDGES. 3. SIGN PANEL TO BE 1/8 THICK PHOTOPOLYMER PANEL. 4. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND VHB TAPE AS REQUIRED. CONTEXT ELEVATION 4 SCALE: 3/16 = 1-0 5. VERIFY WITH LAWA FOR SPECIFIC MESSAGES PER SIGN LOCATION. 1'-9" 1/8 1'-8 C L OF SIGN & COPY 1'-7" 1 7/8" 1 1 6" 1 1 7/8" 1 1 C L DIMENSIONAL LETTERS 2 SIGN PANEL 1 3 NUMBER 2 BACKGROUND PANEL M1 2 STAIR 5 NO ROOF ACCESS 2 EXIT AT LEVEL 1 1 THRU 5 36 SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE

IN CASE OF FIRE EVACUATION PLAN USE EXIT STAIRS 380 WORLD WAY - LEVEL 3 Stair 6 Stair 1 No Roof No Roof Access Access EVAC MAP TBD Pull Fire Alarm Use Stairs Emergency Phone Number: 911 Fire alarm is a loud tone with Do Not Use Elevator flashing strobe You Are Here Fire Pull Exit Route Fire Extinguisher Elevator Area of Evacuation Stairwell Assistance Stair Identity M_6 IN CASE OF FIRE USE EXIT STAIRS EVACUATION PLAN 380 WORLD WAY - LEVEL 3 Stair 6 No Roof Access Stair 1 No Roof Access 3 3 Space from Door Frame 1. EVACUATION PLAN REGULATION SIGNAGE. 2. SIGN BACKGROUND TO BE 1/8 THICK ALUMINUM WITH BRUSHED FINISH ON FACE AND EDGES. EVAC MAP TBD 3. 1/8 THICK PAINTED ACRYLIC SIGN PANEL TO BE ADHERED TO SIGN BACKGROUND IN A PERMANENT MANNER. Pull Fire Alarm Use Stairs Do Not Use Elevator Emergency Phone Number: 911 Fire alarm is a flashing light with voice message You Are Here Exit Route Elevator Stairwell Key Plan Fire Pull Fire Extinguisher Area of Evacuation Assistance RECOMMENDED HEIGHT CONTEXT ELEVATION 6 NOT TO SCALE 4. ALL COPY AND GRAPHICS TO BE SCREEN PRINTED IN COLORS INDICATED AS SHOWN ON 3. 5. FLUSH MOUNT TO EXISTING WALL WITH WELDED THREADED STUDS AND SILICONE ADHESIVE AS REQURIED. 6. LAWA TO PROVIDE BASE MAP ART AND SPECIFIC MESSAGES PER LOCATION OF SIGN. NOTE: SEE PAGE 77 FOR A REDUCE SIZE EVACUATION PLAN, ONLY IF WALL AREA DOES NOT FIT THE SIZE OF THESE SIGNS. 9 1'-4" C L OF SIGN & COPY C L OF SIGN & COPY 2 3/8" COPY 2 4 6 PANEL 1 1 GROUND PANEL 2 M5 PICTOGRAM 2 4 ATTACH TO WALL AS REQUIRED 7 3" 3/8" EVACUATION PLAN 380 WORLD WAY - LEVEL 3 COPY 2 4 1'-2" Stair 6 No Roof Access Stair 1 No Roof Access 3 3/8" 3/8" 3/8" COPY 2 4 EVAC MAP TBD 3 4" 4 SIDE ELEVATION 3 NOT TO SCALE 4 NOT TO SCALE 9 9" SIGN PANEL 1 BACKGROUND PANEL 2 7 1'-7" 3 3/8" 3/8" 3/8" 3/8" 3/2" You Are Here Exit Route Stairwell SIDE ELEVATION 1 NOT TO SCALE 5 NOT TO SCALE Key Plan Fire Pull Fire Extinguisher Area of Evacuation Assistance COPY 2 4 6 PICTOGRAM 2 COPY 2 4 6 37

M_7 Floor Identity STAIR 5 NO ROOF ACCESS 1 EXIT THIS LEVEL 1 THRU 5 TOP OF SIGN 1. ADA AND LOCAL FIRE CODE COMPLIANT WALL MOUNTED IDENTIFICATION PANEL. 2. BACKGROUND PANEL TO BE STAINLESS STEEL WITH BRUSHED FINISH ON FACE AND EDGES. ADHERE TO PHOTOPOLYMER PANEL IN A TAMPERPROOF MANNER. 3. SIGN PANEL TO BE 1/8 THICK PHOTOPOLYMER PANEL. 4. SIGN TO BE FLUSH MOUNTED TO WALL WITH THREADED WELDED STUDS AND SILICONE ADHESIVE AS REQUIRED. CONTEXT ELEVATION 4 SCALE: 3/16 = 1-0 5. PHOTOPOLYMER BRAILLE TO BE GRADE 2 AND PAINTED TO MATCH BACKGROUND COLOR 6. VERIFY WITH LAWA FOR SPECIFIC MESSAGES PER SIGN LOCATION. NOTE: THE STAR INDICATE THE ACTUAL DISCHARGE LEVEL VARIES. 1'-9" 1'-8 C L OF SIGN & COPY 1'-9" 1 1 1 3/8" 6" 1 1 1 1 7/8" C L DIMENSIONAL LETTERS 2 SIGN PANEL 1 3 NUMBER STAR 2 ATTACHED SIGN TO WALL 4 BACKGROUND PANEL M1 2 BRAILLE 1 STAIR 5 NO ROOF ACCESS 1 EXIT THIS LEVEL 1 THRU 5 38 SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE

Area of Assistance Sign M_8 AREA FOR EVACUATION ASSISTANCE Persons able to use stairway, do so as soon as possible. Emergency communications system is available 24 hours a day by using phone for assistance. 380 WORLD WAY - LEVEL 3 1. ADA COMPLIANT WALL MOUNTED IDENTIFICATION PANEL. 2. SIGN BACKGROUND TO BE 1/8 THICK ALUMINUM WITH BRUSHED FINISH ON FACE AND EDGES. ADHERE TO PHOTOPOLYMER PANEL IN A TAMPERPROOF MANNER. Stair 6 No Roof Access Stair 1 No Roof Access 3. COPY AND GRAPHICS TO BE SCREEN PRINTED IN COLORS INDICATED. EVAC MAP TBD 4. MAP TO BE SCREEN PRINTED IN COLORS INDICATED. MAP TO BE UNIQUE PER SIGN LOCATION. MAP SHOWN IS FOR REFERENCE ONLY. MAP ART TO BE PROVIDED BY GENERAL CONRACTOR. FOR ASSISTANCE USE PHONE You Are Here Exit Route Elevator Stairwell Key Plan Fire Pull Fire Extinguisher Area of Evacuation Assistance 5. SIGN TO BE FLUSH MOUNTED TO WALL WITH THREADED WELDED STUDS AND SILICONE ADHESIVE AS REQUIRED. 6. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. LAWA TO PROVIDE MESSAGE SCHEDULE FOR SPECIFIC MESSAGES PER SIGN LOCATION. 1'-0" 1'-4" 1/8" C L OF SIGN & COPY C L OF SIGN & COPY 1/8" 2" SIGN PANEL 1 PANEL 1 1 GROUND PANEL 2 M5 1 COPY 2 3 6 7/8" 7/8" COPY 2 4 COPY 2 4 6 ATTACH TO WALL AS REQUIRED 5 PICTOGRAM 1 3 Stair 6 No Roof Access Stair 1 No Roof Access COPY 2 4 1'-7" 6" 1'-7" PICTOGRAM BACKGROUND 1 3 EVAC MAP TBD PICTOGRAM 2 1 2" 1 NOT TO SCALE 5 3/8" 3/2" Key Plan COPY 2 4 6 SIDE ELEVATION 2 NOT TO SCALE 3 NOT TO SCALE 39

M_9 Area of Evacuation Map/Stair Identity 9 9" 1. TWO PART FABRICATED ALUMINUM AND ACRYLIC SIGN PANEL WITH INTERNAL ILLUMINATION, RECESS INTO WALL. 10" 7/8" 3/8" AREA FOR EVACUATION ASSISTANCE 7/8" 3/8" 7/8" 3/8" 7/8" 1/8" AREA FOR EVACUATION ASSISTANCE 2. UPPER PANEL TO BE TRANSLUCENT ACRYLIC WITH OPAQUE PAINTED OR VINYL FIELD WITH SHOW-THRU INTERNALLY ILLUMINATED COPY AND ACCESSIBLE LOGO. ILLUMINATION TO MEET CODE REQUIREMENTS FOR THIS SIGN. PROVIDE INCONSPICUOUS MAINTENANCE ACCESS. 3. LOWER PANEL TO BE BRUSHED ALUMINUM PANEL WITH PAINTED FIELD. COPY AND GRAPHICS TO BE SCREEN PRINTED IN COLORS INDICATED. 4. ADA COPY TO BE DIMENSIONAL AND PAINTED IN COLOR NOTED. ADA COPY TO MEET ADA REQUIREMENTS. 7/8" 3/8" 3/8" 3/8" 5. 120V CIRCUIT AND BATTERY BACK-UP AS REQUIRED FOR LOW VOLTAGE LED POWER SUPPLY. 6. COORDINATE WITH GENERNAL CONTRACTOR TO PROVIDE WALL RECESS ABD ELECTRICAL FEED AS REQUIRED. 1 NOT TO SCALE 9 SECTION DETAIL 2 NOT TO SCALE 7. BRAILLE TO BE GRADE 2 WITH COLOR TO MATCH BACKGROUND. 8. MESSAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. LAWA TO PROVIDE SPECIFIC MESSAGES PER LOCATION OF SIGN. 9. SIGN TO BE FLUSH MOUNTED ONTO EXISTING FACILITY WALL IN A TAMPER-PROOF MANNER. 2" 3/8" 3/8" C L OF SIGN & COPY COPY 2 4 6 PANEL 1 1 GROUND PANEL 2 M5 NOTE: ALL TEXT MUST COMPLY WITH THE ADA STANDARDS, INCLUDING FONT SIZE, COLOR CONTRAST AND READABILITY FROM A DISTANCE. SEE PAGE 77 FOR A REDUCE SIZE EVACUATION PLAN, ONLY IF WALL AREA DOES NOT FIT THE SIZE OF THESE SIGNS. PICTOGRAM 2 4 ATTACH TO WALL AS REQUIRED 7 1'-4" C L OF SIGN & COPY 1'-2" 3" 3/8" EVACUATION PLAN 380 WORLD WAY - LEVEL 3 PANEL 1 1 GROUND PANEL 2 M5 COPY 2 4 IN CASE OF FIRE USE EXIT STAIRS EVACUATION PLAN 380 WORLD WAY - LEVEL 3 2 3/8" 3/8" 3/8" COPY 2 4 Stair 6 No Roof Access Stair 1 No Roof Access ATTACH TO WALL AS REQUIRED 7 Stair 6 No Roof Access Stair 1 No Roof Access 3/8" EVAC MAP TBD EVAC MAP TBD 4" 4 3 NOT TO SCALE 9 9" SIGN PANEL SIDE ELEVATION 4 NOT TO SCALE 1 7 1'-7" 3 3/8" 3/8" 3/8" 3/8" 3/2" You Are Here Exit Route Stairwell Key Plan Fire Pull Fire Extinguisher Area of Evacuation Assistance COPY 2 4 6 PICTOGRAM 2 COPY 2 4 6 Pull Fire Alarm Use Stairs Do Not Use Elevator Emergency Phone Number: 911 Fire alarm is a flashing light with voice message You Are Here Exit Route Elevator Stairwell Key Plan Fire Pull Fire Extinguisher Area of Evacuation Assistance BACKGROUND PANEL 2 5 NOT TO SCALE SIDE ELEVATION 6 NOT TO SCALE 7 NOT TO SCALE SIDE ELEVATION 8 NOT TO SCALE 40

Tactile Exit Wall M_10 1. TACTILE WALL MOUNTED IDENTIFICATION PANEL. 2. SIGN BACKGROUND TO BE 1/8 THICK ALUMINUM WITH BRUSHED FINISH ON FACE AND EDGES. ADHERE TO PHOTOPOLYMER PANEL IN A TAMPERPROOF MANNER. 3. SIGN PANEL TO BE 1/8 THICK PHOTOPOLYMER PANEL WITH 1/32 RAISED GRAPHICS WITH BRAILLE. 4. PHOTOPOLYMER ADA COMPLIANT LETTERS TO BE MINIMUM 1/32 PROTRUSION FROM FACE OF SIGN AND SCREEN TIPPED IN COLOR NOTED. 5. PHOTOPOLYMER BRAILLE TO BE GRADE 2 AND PAINTED TO MATCH BACKGROUND. 6. SIGN TO BE FLUSH MOUNTED TO WALL WITH THREADED WELDED STUDS AND SILICONE ADHESIVE AS REQUIRED. 7. PROVIDE SIGNAGE IN REQUIRED AREAS WITH PROPER MESSAGING PER ADA AND LOCAL CODES. NOTE: CA-COMPLIANT GRADE 2 BRAILLE BY A CERTIFIED GRADE 2 BRAILLE TRANSLATOR. 9 9" C L 1 (3/8" MIN.) 3/8" 4 3/8" 1 3/8" SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 41

M_11 Exit Only No Re-Entry 1. DOOR MOUNTED ALUMINUM SIGN PANEL WITH SCREEN PRINTED COPY AND SMBOLS, EXIT ONLY NO RE-ENTRY 2. SIGN PANEL TO BE 1/16 THICK BRUSHED ALUMINUM WITH PANTED CENTER. 3. COPY, GRAPHICS AND BACKGROUND FIELD TO BE MASKED AND PAINTED OR SCREENPRINTED. 4. MOUNT TO DOOR WITH VHB TAPE AND SILICONE ADHESIVE AS REQUIRED. FOR GLASS DOOR INSTALLATIONS ADHERE WHITE VINYL CUT TO SIGN PANEL PROPORTIONS TO FIRST SURFACE OF GLASS PRIOR TO INSTALLATION OF SIGN PANEL. 5. CONFIRM MESSAGING WITH LAWA PRIOR TO FABRICATION OF SIGNS. NOTE: MINIMUM TEXT HEIGHT 5/8. 1'-0" 1 SYMBOL BORDER 3. 5" 1 1/8" EXIT ONLY NO RE-ENTRY SYMBOL 3. SYMBOL BACKGROUND 3. P3 1 PAINTED SIGN PANEL 2. P1 COPY 3. SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 42

Restricted Area Door M_12 RESTRICTED AREA TRESPASSING / LOITERING PROHIBITED BY LAW ALL AUTHORIZED PERSONNEL MUST DISPLAY ID BADGE BEYOND THIS POINT L.A.M.C. 56.30 L.A. CITY ORDINANCE NO. 95-789 CONTEXT ELEVATION 7 NOT TO SCALE FINISHED FLOOR 1. SCREENPRINTED GRAPHICS ON OPAQUE WHITE VINLY FILM WITH ADHESIVE BACKING. 2. MOUNT TO FACE OF EXISTING FACILITY DOOR. GLASS DOOR INSTALLATIONS TO HAVE WHITE POLYESTER FILM PROFILE CUT TO MATCH SIGN, ATTACH TO SECOND SURFACE OF GLASS. COLOR TO MATCH RED. 3. REFER TO LAWA FOR EXACT MESSAGE PER LOCATION OF SIGN. 4. COPY AND SYMBOLS TO BE SCREENPRINTED, COLOR AS INDICATED. 5. LAYOUT A TO BE ORDERED THROUGH U.S. CUSTOMS BORDER PROTECTION SEAL TO BE PRINTED BY U.S. CUSTOMS BORDER PROTECTION APPROVED PRINTER ONLY. 1'-4" 3/16" 7/8" 2" 3/16" 1'-4" 1'-4" 7" 7" 7/8" 7/8" LAYOUT A 1 NOT TO SCALE 1'-4" 3/16" 2" 3/16" 1'-0" 7/8" LAYOUT D 4 NOT TO SCALE 3/16" 2" 3/16" 8 7/8" 3/8" LAYOUT F 6 NOT TO SCALE 3/16" 2" 3/16" 1 1/8" LAYOUT B 2 NOT TO SCALE 1'-4" 1'-4" 3/16" 7/8" 3/16" 2" 1'-3 7/8" 3/8" LAYOUT C 3 NOT TO SCALE 2" 3/16" 1'- 3/8 LAYOUT E 5 NOT TO SCALE 3/16" LINE COPY, TYP. 43 07-18-2017

M_13 Poster Frame N.I.C. 6'-10" SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 44 08-04-2015

Poster Stanchion M_14 1'-10" 1. FREESTANDING PORTABLE POSTER STANCHION. 2. 22 X28 DIRECTRAC CURVED BASE, WITH DIRECTRAC POSTER CARTRIDGE. CATALOG NUMBER #50-4501A/SA/SET, SATIN ALUMINUM FINISH. PRE-AP- PROVED FOR TSA USAGE. LAVI INDUSTRIES, LAVI.COM 27810 AVENUE HOPKINS VALENCIA, CA 91355 SALES@LAVI.COM PHONE: (888) 285-8605 3. TSA TO PROVIDE POSTER INSERTS. 2-4 DETAIL 2 NOT TO SCALE 1 NOT TO SCALE 45 08-04-2015

M_15 Poster Stanchion 1'-10" 1. FREESTANDING PORTABLE POST STANCHION. 2. 22" X 28" VERTICAL TRADITIONAL SIGN 2-4 SPECIAL SERVICES 3. 72" POSTS STAND WITH SLOPED BASE, SATIN ALUMINUM FINISH. PRE-APPROVED FOR TSA USAGE. LAVI INDUSTRIES, LAVI.COM 27810 AVENUE HOPKINS VALENCIA, CA 91355 SALES@LAVI.COM PHONE: (888) 285-8605 4. AIRLINES TO PROVIDE POSTER INSERTS. NOTE: IF SIGNS / POSTERS ON THESE STANCHIONS PROVIDE DIRECTION TO OR INFORMATION ABOUT INTERIOR OR EXTERIOR SPACES AND FACILITIES, THEY MUST COMPLY WITH ACCESSIBILITY REQUIREMENTS (CBC 11B-216.3). MOST NOTABLY, SINCE THIS STANCHION IS QUITE TALL, CHARACTERS LOCATED > 70" AFF (TO </= 120" AFF) MEASURED TO THEIR BASELINE MUST BE AT LEAST 2" TALL DEPENDING ON VIEWING DISTANCE (CBC 11B-703.5.5). 6-0 DETAIL 2 NOT TO SCALE 46 08-04-2015 1 NOT TO SCALE

Clearance Path M_16 1. PAINTED GRAPHIC ONTO FLOOR SURFACE. KEEP CLEAR 2. PAINT TO BE SLIP RESISTANT 3. LAWA TO PROVIDE LOCATIONS OF SIGNS. 17'-6" 7" 3'-0" 2. P7 COPY 2. P4 6'-2" 1 NOT TO SCALE 47 08-04-2015

M_17 Clearance Path Wall CAUTION KEEP AREA CLEAR AT ALL TIMES 1. WALL MOUNTED SIGN PANEL. 2. SIGN PANEL TO BE PAINTED ALUMINUM WITH REFLECTIVE VINYL GRAPHICS. 3. MOUNT TO WALL WITH VHB TAPE AND SILICONE ADHESIVE AS REQUIRED. 4. VERIFY LOCATIONS, MESSAGING AND QUANTITIES WITH LAWA. 5. 5/8 MINIMUM TEXT HEIGHT. 1'-2" 1-1 3/8" 5" 1 7/8" 7/8" 1 NOT TO SCALE 48

Clearance Bar M_18 6. COORDINATE WITH GC FOR CLEARANCE HEIGHT DIMENSIONS. 7. 3 MINIMUM TEXT HEIGHT. CEILING STRUCTURE/MATERIAL PLAN ELEVATION 3 NOT TO SCALE 9'-10" ENLARGED SUSPENSION DETAIL 6" 4" 1 NOT TO SCALE REFLECTIVE VINYL LETTERING 4" CAP HT. INTERNAL STRUCTURE AS REQUIRED END ELEVATION 2 NOT TO SCALE 49

M_19 Clearance Wall Mounted ATTACHED TO BUILDING STRUCTURE 3. 3 MINIMUM TEXT HEIGHT. VERIFY FULL WIDTH OF DRIVE AISLE FOR ASSEMBLY STEEL MOUNTING PLATE ATTACHED TO BUILDING STRUCTURE STEEL/CONCRETE ASSEMBLY. VERIFY ASSEMBLY REQUIREMENTS AND CONDITION PRIOR TO FABRICATION CURTAIN WALL SYSTEM GENERAL CONTRACTOR AND FABRICATOR TO CONFIRM WEIGHT OF ASSEMBLY TO ENSURE STRUCTURAL SUPPORT IS ADEQUATE (2) #6 x 1 S.S. PIN-IN-TORX FHSMS SCREW HEADS PAINTED TO MATCH BACKGROUND MMC# 95015A296 CONTEXT ELEVATION 2 NOT TO SCALE 6 DIA. ALUMINUM TUBE CLEARANCE BAR SUSPENDED FROM SOFFIT BANG BAR MOUNTED TO SOFFIT COORDINATE MOUNTING REQUIREMENTS WITH GC. DETAIL 3 NOT TO SCALE 13-0 1 1/2 X 1 1/2 SQUARE TUBE BRACKET AS REQUIRED. ATTACH TO BUILDING FACADE AND/OR TO TUBE SUPPORTS FOR SIGNTYPE MOUNTING BRACKET ATTACHED TO BUILDING SOFFIT WITH S/S HEX BOLT INTO EXPANSION ANCHOR; BOLT GOES THRU SOFFIT PANEL & RIGID INSULATION; EXPANSION ANCHOR & DRILLED HOLE IN SOFFIT PANEL BY GC; QTY. OF ANCHORS AS REQ D. END VIEW NOTE: VERIFY SOFFIT CONSTRUCTION AT LOCATION. SECTION THRU PARKING STRUCTURE ENTRY SOFFIT 4" 50 08-04-2015 1 NOT TO SCALE 1 1/2 X 1 1/2 SQUARE TUBE BRACKET AS REQUIRED. ATTACH TO BUILDING FACADE AND/OR TO TUBE SUPPORTS FOR SIGNTYPE

Room Identity R_1 2-1-CR01 1. ADA COMPLIANT ROOM IDENTIFICATION SIGNAGE. 2. SIGN PANEL TO BE 1/4 THICK PHOTOPOLYMER MOUNTED TO WALL. 3. PHOTOPOLYMER DIMENSIONAL LETTERS TO BE MINIMUM 1/32 PROTRUSION FROM SIGN FACE AND SCREEN-TIPPED IN COLOR INDICATED. 4. PHOTOPOLYMER GRADE 2 BRAILLE TO BE ADA COMPLIANT WITH COLOR TO MATCH BACKGROUND COLOR. 5. SIGN TO BE MOUNTED TO WALL WITH VHB TAPE AND SILICONE ADHESIVE AS REQUIRED. 6. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS AND MESSAGES PER SIGN LOCATION. NOTE: DUAL-PURPOSE SIGN MUST INCLUDE BOTH VISUAL AND TACTILE FORMATS. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF CHARACTERS MUST BE 135% MINIMUM AND 175% MAXIMUM OF THE CHARACTER HEIGHT (CBC 11B-703.2.8). NEITHER A BASELINE-TO-BASELINE DIMENSION NOR A DIMENSION BETWEEN LINES OF RAISED TEXT IS PROVIDED. CA-COMPLIANT GRADE 2 BRAILLE BY A CERTIFIED GRADE 2 BRAILLE TRANSLATOR. 1/4 3/8 3/8" 3/8" 5/16" 5/8 5/8 5/16" 5/8 VINYL NUMERALS (WHITE) (NO COLOR) 7/8" 6" Front Elevation 2 NOT TO SCALE Side Elevation 2 NOT TO SCALE 51

R_2 Multiple Room Identity 1. ADA COMPLIANT ROOM IDENTIFICATION SIGNAGE WITH REPLACEABLE NAME PANELS. 2. SIGN PANEL TO BE 1/4 THICK PHOTOPOLYMER MOUNTED TO 1/8 THICK ALUMINUM BACKGROUND PANEL. 3. BACKGROUND PANEL TO BE PAINTED ALUMINUM, PERMANENTLY ATTATCHED TO SIGN PANEL AND REPLACEABLE PANEL EXTRUSION. 4. PHOTOPOLYMER DIMENSIONAL LETTERS TO BE MINIMUM 1/32 PROTRUSION FROM SIGN FACE AND SCREEN-TIPPED IN COLOR INDICATED. 5. PHOTOPOLYMER GRADE 2 BRAILLE TO BE ADA COMPLIANT WITH COLOR TO MATCH BACKGROUND COLOR. 6. PANEL GUIDES TO BE BRUSHED ALUMINUM REPLACEABLE PANEL EXTRUSION OR FABRICATED AS REQUIRED. 10 1/8" 5/16" 5/16" 3/8" 3/8" 3/8" 7/8" 7/8" 7/8" 7/8" 9 VINYL NUMBERALS (WHITE) DIMENSIONAL LETTERS (NO COLOR) SIGN PANEL 2. ADA LETTERS 4. BRAILLE 5. PANEL GUIDES 6. REPLACEABLE PANEL COPY 7. REPLACEABLE PANELS 7. 1/8" 7. REPLACEABLE PANELS TO BE PAINTED ACRYLIC WITH VINYL COPY. PANELS TO BE HELD IN PLACE WITH HIDDEN FASTENERS. 8. SIGN TO BE MOUNTED TO WALL WITH THREADED WELDED STUDS AND SILICONE ADHESIVE AS REQUIRED. 9. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. LAWA TO PROVIDE MESSAGE SCHEDULE FOR SPECIFIC MESSAGES PER LOCATION OF SIGNS. 10. 3/8 MINIMUM FOR BRAILLE HEIGHT. NOTE: CA-COMPLIANT GRADE 2 BRAILLE BY A CERTIFIED GRADE 2 BRAILLE TRANSLATOR. 2-1-CR01 2-1-CR01 CBP TRAINING Mr. John Doe 0ffcr. Jane Doe SECTION DETAIL 1 NOT TO SCALE 2 NOT TO SCALE 52 08-04-2015

Defibrillator Identity Blade R_3 1. DOUBLE-FACED, NON-ILLUMINATED WALL MOUNTED SIGN PANEL. 2. SIGN PANEL TO BE 1/4 THICK ALUMINUM WITH WHITE PAINTED FACE. 3. COPY AND PICTOGRAMS TO BE VINYL-DIE-CUT IN COLORS INDICATED. 4. FABRICATED ALUMINUM MOUNTING PLATE WITH BRUSHED FINISH. 5. ATTACH SIGN TO FACILITY WALL WITH STAINLESS STEEL COUNTERSUNK FASTENERS AS REQUIRED. 6'-8" MIN. 6. VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGN. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE ADDITIONAL BLOCKING AS REQUIRED. 1-4 1 3 1 1-6 7 1/2 1-6 1 3/4 5/8 3/4 5/8 3/4 1 P5 1 NOT TO SCALE MOUNTING PLATE 2 NOT TO SCALE 53 08-04-2015

R_4 Defibrillator Identity Vinyl 1. PRINTED DECAL ON WHITE BACKGROUND. 2. VERIFY WALL CONDITIONS / BINNACLE PRIOR TO FABRICATION OF SIGN 1-4 1 3 1 1 P5 5/8 5/8 1 1 1 1-6 5-10 3/4 3/4 3/4 1 NOT TO SCALE 54 08-04-2015

General Services Identity R_5 1. DOUBLE-FACED, NON-ILLUMINATED, WALL MOUNTED BLADE SIGN. 2. FABRICATED ALUMINUM SIGN CABINET. 3. PICTOGRAMS TO BE FLAT-CUT OUT 1/4 THICK ALUMINUM PANITED IN COLORS NOTED. PICTOGRAMS TO BE MOUNTED TO SIGN PANEL WITH HIDDEN MECHANI- CAL FASTENERS. 6'-8" 4. SIGN PANEL TO BE 1/4 THICK WITH FACE AND EDGES PAINTED IN COLOR AS NOTED. CONTEXT ELEVATION 5 NOT TO SCALE 5. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLATION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEER- ING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRAC- TOR FOR STRUCTURAL REQUIREMENTS. 6. ESTIMATED SIGN WEIGHT: 50 LBS EACH. 7. VERIFY SPECIFIC MESSAGE PER SIGN LOCATION WITH LAWA. 1'-3" C L 1'-3" C L 1'-3" C L SIGN PANEL 4. 3. 7. 5. 10 7/8" 8" 1 3/16 1 3/16 1 15/16 1 10 ALL GENDER RESTROOM VOLUME CONTROL TELEPHONE CLEAN AIR 1'-3" 1'-3" C L C L SIDE CABINET 2 RESTROOMS 3 MOUNTING PLATE 2 NOT TO SCALE 1 NOT TO SCALE 10 10 NURSING ROOM TTY HEARING LOSS 10 10 9 3/8" 10 6 1/8" 8 3/8" ELEVATORS PUBLIC PHONE COURTESY PHONE INFORMATION ESCALATORS ATM PET AREA SMOKING VENDING MACHINES ADDITIONAL LAYOUTS 6 NOT TO SCALE 55

R_6 Restroom Identity Door CIRCLE AND TRIANGLE SIGN PANELS TO BE 1/4 PHOTOPOLYMER WITH SILICONE ADHESIVS AND DOUBLE-SIDE TAPE. 4'-10" to 5'-0" 6. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS AND MESSAGES PER SIGN LOCATION. CONTEXT ELEVATION 5 NOT TO SCALE 12 12 12 MEN WOMEN ALL GENDER SIDE VIEWS 1 NOT TO SCALE 2 NOT TO SCALE 3 NOT TO SCALE 4 NOT TO SCALE 56

Restroom Identity Wall R_7 1. ADA COMPLIANT ROOM IDENTIFICATION SIGNAGE. 2. SIGN PANEL TO BE 1/8 THICK PHOTOPOLYMER. PAINT TO MATCH COLOR INDICATED. 3. PHOTOPOLYMER DIMENSIONAL LETTERS TO BE MINIMUM 1/32 PROTRUSION FROM SIGN FACE. LETTERS TO BE SCREEN-TIPPED IN COLOR INDICATED. 4. PHOTOPOLYMER CA-COMPLIANT GRADE 2 BRAILLE BY A CERTIFIED GRADE 2 BRAILLE TRANSLATOR WITH COLOR TO MATCH BACKGROUND COLOR. 5'-0" MAX 4'-0" MIN 5. SIGN TO BE MOUNTED TO WALL WITH THREADED WELDED STUDS AND SILICONE ADHESIVE AS REQUIRED. 6. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS AND MESSAGES PER SIGN LOCATION. NOTE: SIGN MOUNTING HEIGHT IS NOT SHOWN OR NOTED. AS WITH ALL ROOM IDENTIFICATION SIGNAGE, THESE SIGNS ARE REQUIRED TO BE MOUNTED NO LOWER THAN 48" AFF MEASURED TO THE BASELINE OF THE LOWEST LINE OF BRAILLE CELLS, AND NO HIGHER THAN 60" AFF MEASURED TO THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. (CBC 11B-703.4.1). CONTEXT ELEVATION 4 NOT TO SCALE 1/8" 1/8" 4" 2 3 2 3 2 1 3 3 3/8" 4 4 WOMEN FAMILY ALL GENDER SIDE ELEVATION ADDITIONAL LAYOUTS 1 NOT TO SCALE 2 NOT TO SCALE 3 NOT TO SCALE 57

R_8 Restroom Identity No Door 1. ADA/TITLE 24 COMPLIANT ROOM IDENTIFICATION SIGNAGE. 2. SIGN PANEL TO BE 1/4 THICK PHOTOPOLYMER WITH PAINTED EDGE AND BORDER. UNISEX VERSION TO BE PERMANENTLY MOUNTED TO BACKGROUND PANEL. 3. BACKGROUND PANEL FOR UNISEX VERSION ONLY TO BE PHOTOPOLYMER. PAINT TO MATCH COLORS INDICATED. 4. PICTOGRAMS/LETTERS TO BE SCREEN PRINTED IN COLOR INDICATED. 5. SIGN TO BE MOUNTED TO WALL WITH THREADED WELDED STUDS AND SILICONE ADHESIVE AS REQUIRED. 6. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS AND MESSAGES PER SIGN LOCATION. WOMEN NOTE: RAISED LETTERS AND BRAILLE ARE NOT REQUIRED, NOR SHOLD IT BE PROVIDED ON THESE SIGNS, ESPECIALLY IF MOUNTED ON SWINGING DOORS. 1'-0" 11 8" 6 1'-0" 9" 7/8" 4" 4" BACKGROUND BORDER 3. SCREEN PRINTED LETTERS 7/8" 7/8" 4 2 BACKGROUND FIELD P1 4 P2 SIGN PANEL BORDER P3 SCREEN PRINTED LETTERS 7/8" 1'-0" 8 7/8" 4 3 3/8" BACKGROUND FIELD P1 4 P2 SIGN PANEL BORDER P3 SCREEN PRINTED LETTERS - ALL GENDER 1 NOT TO SCALE SIDE VIEW - ALL GENDER SIDE VIEW - MEN/WOMEN 2 NOT TO SCALE 3 NOT TO SCALE FRONT VIEW-MEN/WOMEN 4 NOT TO SCALE 58

General Services Identity Wall R_9 1. WALL MOUNTED IDENTIFICATION SIGNAGE. 2. SIGN PANEL TO BE 1/8 THICK PHOTOPOLYMER. PAINT TO MATCH COLOR INDICATED. 3. SIGN TO BE MOUNTED TO WALL WITH VHB TAPE AND SILICONE ADHESIVE AS REQUIRED. 4. COORDINATE WITH LAWA FOR SPECIFIC LOCATIONS AND MESSAGES PER SIGN LOCATION. PET AREA 2 ELEVATORS NURSING ROOM 2 PHONES ATM SIDE VIEW 2 NOT TO SCALE 1 NOT TO SCALE ACCESSIBLE ADDITIONAL LAYOUTS 4 NOT TO SCALE DRINKING FOUNTAIN 59

W_1 CBP Identity Sign 1 DOUBLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4 DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON DRAWING. 5. PRIOR TO BID SUBMISSION, FIELD VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGN. DETERMINE BEST METHOD FOR SIGNAGE INSTALLA- TION. PROVIDE STRUCTURAL ENGINEERING CALCULATIONS. Cashier 6. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE ADDITIONAL SIGNAGE SUPPORT AS REQUIRED. 7. VERTICAL SUPPORTS WITH DECORATIVE CLADDING AS REQUIRED. PROVIDE SMALLEST DIAMETER AS ALLOWED BY STRUCTURAL ENGINEERING CALCULATIONS. 8. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND LOCATION OF SIGN TO BE PROVIDED BY LAWA. 9. THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. 4'-0" 5. 6. ESCUCHEON PLATE 7. 4 1'-6" 1'-4" 7" 4" 2. 3. 6'-8" MIN. PICTOGRAM 4. 9. PICTOGRAM FIELD 4. 4. 3" 1 NOT TO SCALE END VIEW 2 NOT TO SCALE 60

Pedestrian Directional Smaller Overhead W_2 1. DOUBLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. Gates 130-144 Bag Claim Restrooms 3. SIGN PANEL TO BE 3/4 DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON DRAWING. 5. PRIOR TO BID SUBMISSION, FIELD VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGN. DETERMINE BEST METHOD FOR SIGNAGE INSTALLATION WITH CONCEALED MECHANICAL FASTERNERS. PROVIDE STRUCTURAL ENGINEERING CALCULATIONS. NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. 3" TOP VIEW 1 NOT TO SCALE 6' 1'-6" 7/8" 3" TYP. 4 4 7/8" 6'-8" MIN. 7 1 NOT TO SCALE SIDE ELEVATION 2 NOT TO SCALE 3" 61 07-18-2017

W_3 Pedestrian Directional Overhead Gates 130-144 Restrooms Restaurants 1. DOUBLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET. 6'-8" MIN. VERIFY CLEARANCE IN FIELD FINISHED FLOOR 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4 DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON DRAWING. 5. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLATION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS. 6. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID SUBMISSION. 7. VERTICAL SUPPORTS WITH DECORATIVE CLADDING AS REQUIRED. PROVIDE SMALLEST DIAMETER AS ALLOWED BY STRUCTURAL ENGINEERING CALCULA- TIONS. 3/4 8. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND LOCATION OF SIGN TO BE PROVIDED BY LAWA. 4 3/4 PLAN VIEW 3 NOT TO SCALE 7 NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. 15'-8" 4" 1'6" 11 4" 5" 10" 6" 4" 3" 4" 2 5" 4" 2 4" 5 TYPICAL INLAYED SYMBOL 4. SYMBOL BACKGROUND 4. 4 END VIEW 1 NOT TO SCALE 2 NOT TO SCALE 62

CBP Directional Static/Dynamic Overhead W_4 Federal Inspection Services Ground Transport 1. DOUBLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET WITH LED DISPLAYS. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4 DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS NOTED. Bag Claim 4-8 Oversize Bag Claim 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON DRAWING. 5. LED DISPLAY TO BE PROVIDED BY LAWA. PROVIDE MANUFACTURER S REQUIREMENTS FOR VENTILATION IN SIGN CABINET. ALLOW FOR EASE OF MAINTENANCE WITH INCONSPICUOUS ACCESS PANELS. 6. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA- TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS. 7. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID SUBMISSION. 6'-8" MIN. VERIFY CLEARANCE IN FIELD FINISHED FLOOR 8. VERTICAL SUPPORTS AND BRACKET WITH DECORATIVE CLADDING AS REQUIRED. PROVIDE SMALLEST DIAMETER AS ALLOWED BY STRUCTURAL ENGINEERING CALCULATIONS. 9. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND LOCATION OF SIGN TO BE PROVIDED BY LAWA. NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. PLAN VIEW 3 NOT TO SCALE 12'-0" CEILING 7. ESCUCHEON PLATE 8. ARROW 4. 2 1 4" 5 3 2 3/8" 1'-4" 1'-6" 4" 2 5" LED DISPLAY 5. COPY AND GRAPHICS 4. PICTOGRAM FIELD 4. (SIDE A) END ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 6" 63 07-18-2017

W_5 CSR Static Dynamic Overhead Customer Service Representative 1. SINGLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET WITH LED DISPLAYS. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4 DEEP FABRICATED ALUMINUM. FACE AND RETURNS TO BE PAINTED IN COLOR AS NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON DRAWING. 5. LED DISPLAY SPECIFICATIONS TO BE APPROVED BY LAWA. PROVIDE MANUFACTURER S REQUIREMENTS FOR VENTILATION IN SIGN CABINET. ALLOW FOR EASE OF MAINTENANCE WITH INCONSPICUOUS ACCESS PANELS. 6. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA- TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS. 6'-8" MIN. VERIFY CLEARANCE IN FIELD FINISHED FLOOR 7. VERTICAL SUPPORTS AND BRACKET WITH DECORATIVE CLADDING AS REQUIRED. PROVIDE SMALLEST DIAMETER AS ALLOWED BY STRUCTURAL ENGINEERING CALCULATIONS. 8. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND LOCATION OF SIGN TO BE PROVIDED BY LAWA. NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. 6" PLAN VIEW 3 NOT TO SCALE 11'-0" 10'-10" SUPPORTS 7. 2'-0" 7" 3" 2" 3" LED DISPLAY 5. SIGN FACE 3. 64 7" ELEVATION 1 NOT TO SCALE SIGN CABINET 2. END VIEW 2 NOT TO SCALE

Wall Identity W_6 1. NON-ILLUMINATED, WALL MOUNTED FABRICATED ALUMINUM SIGN CABINET. 2. ALUMINUM SIGN CABINET TO BE FABRICATED IN A MANNER TO ALLOW EASE OF MAINTENANCE. PROVIDE INTERNAL SUPPORT AS REQUIRED. 3. SIGN FACE TO BE PAINTED ALUMINUM ATTACHED TO SIGN CABINET WITH BLIND FASTENERS. 4. COPY AND GRAPHICS TO BE VINYL DIE-CUT IN COLOR INDICATED ON DRAWING. 5. VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGN. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE ADDITIONAL BLOCKING AS REQUIRED. CONNECTION DETAILS AND STRUCTURAL CALCULATIONS TO BE VERIFIED BY STRUCTURAL ENGINEERING CALCULATIONS. 6. VERIFY FINAL MESSAGE AND LOCATION OF SIGN WITH LAWA. NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. 6'-8" MIN. VERIFY CLEARANCE IN FIELD FINISHED FLOOR 5'-10" 1 5 1'-6" 1 7" 4" SIGN CABINET 2. SECTION DETAIL 1 NOT TO SCALE 2 NOT TO SCALE 65

W_7 Pedestrian Directional Small Overhead 1. DOUBLE-FACED, NON-ILLUMINATED, CEILING MOUNTED SIGN CABINET. EXIT and Connecting Flights Ground Transport Elevators Restrooms Information Upper Boarding 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4 DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON DRAWING. 5. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE ADDITIONAL SIGNAGE SUPPORT AS REQUIRED. 6. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA- TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS. 7. VERTICAL SUPPORTS WITH DECORATIVE CLADDING AS REQUIRED. PROVIDE SMALLEST DIAMETER AS ALLOWED BY STRUCTURAL ENGINEERING CALCULA- TIONS. 8. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND LOCATION OF SIGN TO BE PROVIDED BY LAWA. 6'-8" MIN. NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. 1'-6" 1 1/8" 4" 1 3/8" 3" 1 3/8" 5 6 7 4" 1 1/8" 66 07-18-2017 9 SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 3"

Small Directional Wall W_8 Bag Claim Restrooms Exit 1. SINGLE-FACED, NON-ILLUMINATED, WALL MOUNTED SIGN CABINET. 2. FABRICATED SIGN CABINET WITH INTERNAL FRAMING AS REQUIRED. 3. SIGN PANEL TO BE 3/4 DEEP FABRICATED ALUMINUM WITH PAINT FINISH AS NOTED. 4. COPY AND GRAPHICS TO BE VINYL DIE CUT IN COLORS INDICATED ON DRAWING. 5. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA- TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS. 6. FIELD VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGN. 7. SIGNAGE SHOWN IS FOR PLACEMENT PURPOSES ONLY. FINAL MESSAGE AND LOCATION OF SIGN TO BE PROVIDED BY LAWA. NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. 5. PARTIAL SECTION DETAIL 3 NOT TO SCALE 6'-8" MIN. VERIFY CLEARANCE IN FIELD FINISHED FLOOR 6'-0" 1 1/8" 4" 1'-6" 1 3/8" 3" 1 3/8" 4" 1 1/8" 1 NOT TO SCALE TYPICAL INLAYED SYMBOL 4. SYMBOL BACKGROUND 4. 8. 5. SIDE ELEVATION 2 NOT TO SCALE 67 07-18-2017

W_9 Wayfinding Directional Wall 1. WALL MOUNTED PLAQUE WITH PAINTED BACKGROUND AND SCREENED GRAPHICS. 2. SIGN PANEL TO BE 1/8 THICK BRUSHED ALUMINUM WITH MASKED AND PAINTED BACKGROUND. 3. COPY TO BE VINYL DIE-CUT WITH COLOR TO MATCH AS INDICATED ON DRAWING. Rooms 00-00 Rooms 00-00 4. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND VHB TAPE AS REQUIRED. 5. LAWA TO PROVIDE SPECIFIC MESSAGE PER LOCATION OF SIGN. NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. BASELINE OF CHARACTERS 6'-8" Max. VERIFY CLEARANCE IN FIELD FINISHED FLOOR 5'-0" 10" 2 3" 2" 2 BACKGROUND FIELD 1 NOT TO SCALE 2 68 08-04-2015

Pedestrian Direction Wall W_10 Gates 130-144 Restrooms Restaurants 1. NON-ILLUMINATED, WALL MOUNTED FABRICATED ALUMINUM SIGN CABINET. 2. ALUMINUM SIGN CABINET TO BE FABRICATED IN A MANNER TO ALLOW EASE OF MAINTENANCE. PROVIDE INTERNAL SUPPORT AS REQUIRED. 3. SIGN FACE TO BE PAINTED ALUMINUM ATTACHED TO SIGN CABINET WITH BLIND FASTENERS. 4. COPY AND GRAPHICS TO BE VINYL DIE-CUT IN COLOR INDICATED ON DRAWING. 5. VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION OF SIGN. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE ADDITIONAL BLOCKING AS REQUIRED. CONNECTION DETAILS AND STRUCTURAL CALCULATIONS TO BE VERIFIED BY STRUCTURAL ENGINEERING CALCULATIONS. 6. VERIFY FINAL MESSAGE AND LOCATION OF SIGN WITH LAWA. 6'-8" MIN. VERIFY CLEARANCE IN FIELD NOTE: THE SCALE OF THE SIGNAGE AND GRAPHICS ARE SUBJECT TO CHANGE IN ORDER TO BE COMPLIANT WITH ADA GUIDELINES IF THE INSTALLATION SITE EXCEEDS THE HEIGHT SHOWN IN THE DRAWING PROVIDED. FINISHED FLOOR 1 VARIES 4 1'-6" 7" 1 4" 2 4" 2 6" 4 1 4" 2 SIGN CABINET 2 1 NOT TO SCALE SECTION DETAIL 2 NOT TO SCALE 69

W_11 Informational Sign Placard 1. WALL MOUNTED PLAQUE WITH PAINTED BACKGROUND OR SCREENED GRAPHICS. 2. SIGN PANEL TO BE 1/8 THICK PHOTOPOLYMER COLOR TO MATCH THE SCREEN PRINTED GRAPHICS. 3. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND VHB TAPE AS REQUIRED. 4. TYPESTYLE: HELVETICA NEUE LT PRO 65 MEDIUM. 5. LAWA TO PROVIDE SPECIFIC MESSAGE PER LOCATION OF SIGN. 2'-6" 1'-6" 1 1 2 In the course of normal handling, your luggage may acquire evidence of use, such as minor cuts, scratches, dents or soil. We trust you to understand that we are not responsible for conditions that result from this type of normal wear and tear. Thank You. 1 NOT TO SCALE 70

Directional Sign Placard W_12 1. WALL MOUNTED PLAQUE WITH PAINTED BACKGROUND OR SCREENED GRAPHICS. 2. SIGN PANEL TO BE 1/8 THICK PHOTOPOLYMER COLOR TO MATCH THE SCREEN PRINTED GRAPHICS. 3. FLUSH MOUNT ONTO EXISTING INTERIOR WALL WITH SILICONE ADHESIVE AND VHB TAPE AS REQUIRED. 4. TYPESTYLE: HELVETICA NEUE LT PRO 65 MEDIUM. 5. LAWA TO PROVIDE SPECIFIC MESSAGE PER LOCATION OF SIGN. NOTE: VARIANCES 2'-6" 2" 1'-6" 1 1 6 2 Gates 30-39 Located in Terminal 3 1 1/8" 1 1/8" (Alternate text or foreign language) 2" 1 NOT TO SCALE 71

3 P-3 Center Way P-4 Way West Departure Arrival P-2 P-2A P-5 P-6 Arrival Departure 2 Upper Level Lower Level VP-6 Lower Level Upper Level 1 P-1 P-7 Cell Phone Waiting Lot Airport Blvd. & Arbor Vitae St. Lincoln Blvd. 1 1 96th St. Bridge Long-Term Public Parking Lot C Free Bus Service to Airline Terminals 105 W. 98th St. NORTH Lot B 111th & La Cienega Blvd. Metro Rail Green Line Imperial Hwy. & Aviation Blvd. Long-Term Public Parking Lot B Free Bus Service to Airline Terminals 111th St. Imperial Hwy 104th St. Arbor Vitae St. 405 405 W_13 Small Freestanding Directional 4'-0" 4" 1. DOUBLE-FACED, NON ILLUMINATED, FREESTANDING PYLON SIGN WITH REPLACEABLE MAP DIRECTORY. 2" 2 1/8" 2 2. FABRICATED ALUMINUM CABINET WITH INTERNAL STRUCTURE AS REQUIRED. 3. SIGN PANELS TO BE FABRICATED ALUMINUM PAINTED IN COLOR INDICATED. ATTACH TO SIGN CABINET IN AN INCONSPICUOUS MANNER. 2 4. COPY AND GRAPHICS TO BE VINYL DIE-CUT TO MATCH COLORS INDICATED ON DRAWING. 2" 1 3/8" 2" 1 3/8" 2" 1 3/8" 2" 1 3/8" 2" 1 3/8" 2" COPY AND GRAPHICS 4. 5. LED DISPLAY SPECIFICATIONS TO BE APPROVED BY LAWA. PROVIDE MANUFACTURER S REQUIREMENTS FOR VENTILATION IN SIGN CABINET. ALLOW FOR EASE OF MAINTENANCE WITH INCONSPICUOUS ACCESS PANELS. 6. DESIGNER TO FIELD VERIFY EXISTING CONDITIONS AND COORDINATE WITH GENERAL CONTRACTOR FOR BEST METHOD OF INSTALLATION. DESIGNER TO PROVIDE STRUCTURAL AND FOOTING REQUIREMENTS BASED ON STRUCTUR- AL ENGINEERING CALCULATIONS. 7. LAYOUT SHOWN IS FOR PLACEMENT PURPOSES ONLY. LAWA TO PROVIDE SPECIFIC MESSAGES PER SIGN LOCATION. 3 8'-0" 7'-4" 2'-8" DIRECTORY/MAP 5. Gates 130-148 N. Concourse Airline Lounges Shopping Restrooms Concessions Wes t SIGN PANEL 3. Sky Way W. 96th St. Airport Blvd. La Cienega Blvd. Tom Bradley International Terminal VP-4 West Way Upper Level Lower Level East Way Lower Level East Way Upper Level Century Blvd. From I-405 Fwy. SIGN CABINET 2. 4 5 6 7 8 S epulve da Blvd. 2'-5" BASE COVER 8" FOOTING 7. SIDE ELEVATION 1 NOT TO SCALE 2 NOT TO SCALE 72

Freestanding Directory W_14 1. DOUBLE-FACED, NON ILLUMINATED, FREESTANDING PYLON SIGN WITH VINYL COPY. 2'-6" 2. FABRICATED ALUMINUM CABINET WITH INTERNAL STRUCTURE AS REQUIRED. 2 7/16" 5 1/8" 1 1/8" 1 1/8" 3. SIGN PANELS TO BE FABRICATED ALUMINUM PAINTED IN COLOR INDICATED. ATTACH TO SIGN CABINET IN AN INCONSPICUOUS MANNER. 4. COPY AND GRAPHICS TO BE VINY DIE-CUT APPLIED TO SIGN PANEL. 8" 5. FIELD VERIFY EXISTING CONDITIONS. COORDINATE WITH GENERAL CONTRAC- TOR FOR BEST METHOD OF INSTALLATION. PROVIDE STRUCTURAL AND FOOTING REQUIREMENTS BASED ON STRUCTURAL ENGINEERING CALCULA- TIONS. 3 3/8" 1 4 1/8" 6. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLATION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS. 6 2" TYP 7. FABRICATED BASE COVER TO BE FABRICATED IN A MANNER TO WITHSTAND ABUSE FROM LUGGAGE CARTS. 5'-10" 4 1/8" 3 3/8" 4 1/8" 8. MESSAGES SHOWN ARE FOR PLACEMENT PURPOSES ONLY. LAWA TO PROVIDE SPECIFIC MESSAGES PER SIGNAGE LOCATION. 6 8'-0" 4 1/8" 3 3/8" SIGN CABINET 2. M1 Gates 4 1/8" 3 3/8" Escalator 4 1/8" Lounge Elevator Shopping 40" MIN. Restrooms Food BASE 7. M1 FINISHED FLOOR 6. 1 NOT TO SCALE SIDE ELEVATION 2 NOT TO SCALE 73

W_15 Large Freestanding Directional 9 1. DOUBLE-FACED, NON ILLUMINATED, FREESTANDING PYLON SIGN WITH MONITOR, POSTER CABINET AND VINYL COPY. 2. FABRICATED ALUMINUM CABINET WITH INTERNAL STRUCTURE AS REQUIRED. 3. SIGN PANELS TO BE FABRICATED ALUMINUM PAINTED IN COLOR INDICATED. ATTACH TO SIGN CABINET IN AN INCONSPICUOUS MANNER. PLAN VIEW 3 NOT TO SCALE 4. COPY AND GRAPHICS TO BE VINY DIE-CUT APPLIED TO SIGN PANEL. 5. FIELD VERIFY EXISTING CONDITIONS. COORDINATE WITH GENERAL CONTRACTOR FOR BEST METHOD OF INSTALLATION. PROVIDE STRUCTURAL AND FOOTING REQUIREMENTS BASED ON STRUCTURAL ENGINEERING CALCULATIONS. 14'-0" 3 1/8" 3 1 3 3 7/8" 3 1 3 3 7/8" 3 1 3 1'-2 2" 1 2" 1 2" 1 2" 5 2" 1 2" 1'-10 3/8" 3" 2'-3" 2'- SIGN CABINET 2. M1 TYP. COPY P2 AND GRAPHICS 5. SIGN PANEL 3. SUGGESTED SEAM LOCATION MONITOR 8. P1 1'-4" 1'-2" SIGN CABINET 2. M1 TYP. COPY AND GRAPHICS 4. SIGN PANEL 3. P1 SUGGESTED SEAM LOCATION P2 6. LED DISPLAY SPECIFICATIONS TO BE APPROVED BY LAWA. PROVIDE MANUFACTURER S REQUIREMENTS FOR VENTILATION IN SIGN CABINET. ALLOW FOR EASE OF MAINTENANCE WITH INCONSPICUOUS ACCESS PANELS. 7. POSTER RETAINER TO BE TEMPERED GLASS WITH FABRICATED FRAME TO MATCH SIGN PANEL. PROVIDE CONTINUOUS HINGE AND TWO LOCKS KEYED ALIKE. PROVIDE TOOL-LESS FASTENERS AND BACKER PANEL TO RETAIN POSTER. 8. MONITOR TO BE PROVIDED BY LAWA. INSTALL IN A MANNER TO ALLOW EASE OF MAINTENANCE. FOLLOW MANUFACTURERS RECCOMENDATIONS FOR INSTALLATION INCLUDING VENTILATION REQUIREMENTS. 9. DESIGNER TO FIELD VERIFY AND DETERMINE BEST METHOD OF INSTALLA- TION WITH MINIMAL VISUAL IMPACT. DESIGNER TO PROVIDE STRUCTURAL ENGINEERING CALCULATIONS AS REQUIRED AND COORDINATE WITH GENERAL CONTRACTOR FOR STRUCTURAL REQUIREMENTS. 10. ESTIMATED SIGN WATTAGE REQUIREMENTS: 2500W ESTIMATED SIGN WEIGHT: 1200 LBS. 11. MESSAGES SHOWN ARE FOR PLACEMENT PURPOSES ONLY. LAWA TO PROVIDE SPECIFIC MESSAGES PER SIGNAGE LOCATION. Gates 150-159 Gates 130-146 MONITOR OPENING 8. CONTINUOUS HINGE Lounge Escalators Elevators Restrooms Restaurants Duty Free 5'-10" MAX. TYP. LOCKS 7. 74 ELEVATION (SIDE A) 1 NOT TO SCALE END ELEVATION ELEVATION (SIDE B) 2 NOT TO SCALE 4 NOT TO SCALE OPTION 1