Quadrupole Power Supply Unit QPS400-3

Similar documents
TPS TRANSDUCER POWER SUPPLY & LEM IT CURRNET TRANSDUCER

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

IMPORTANT SAFETY INSTRUCTIONS

Modular Smart Interfaces

Professional Power Amplifier

CIRCUIT-TEST ELECTRONICS

OP07C PRECISION OPERATIONAL AMPLIFIERS

Models 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument

Model Quality in Test and Measurement Since 1949 OUTSTANDING PERFORMANCE DESCRIPTION APPLICATIONS ADDITIONAL FEATURES

Type Ordering Code Package TAA 762 A Q67000-A2271 P-DIP-6-1 TAA 762 G Q67000-A2273 P-DSO-6-1 (SMD) TAA 765 A Q67000-A524 P-DIP-6-1

5000 Series Receiver Systems

High Power Piezo Driver

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DSSIU-6-1U-V. Features VOM:

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE EXT-02 B EXTRACELLULAR AMPLIFIER

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

5MHz FUNCTION GENERATOR

Variable-Gain High Speed Current Amplifier

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

LF153 LF253 - LF353 WIDE BANDWIDTH DUAL J-FET OPERATIONAL AMPLIFIERS

USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER

5MHz FUNCTION GENERATOR

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Variable Gain Low Frequency Voltage Amplifier

DS10000ULFS-10V/10kA

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

AC/DC Resistance Standard DRR-112

INTEGRATED CIRCUITS DATA SHEET. TDA1074A Dual tandem electronic potentiometer circuit. Product specification File under Integrated Circuits, IC01

LF147 - LF247 LF347 WIDE BANDWIDTH QUAD J-FET OPERATIONAL AMPLIFIERS

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

AMP-13 OPERATOR S MANUAL

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

User Manual. ia480x Power amplifier

AUDIO2-4 for imc CRONOSflex (CRFX/AUDIO2-4)

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

Oscilloscope Current Probe Adapter Plus

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

ASK Cards. Features Analog signal isolation Digital signal isolation. Applications

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Advanced Test Equipment Rentals ATEC (2832)

Power Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Dual Channel Power Amplifier D2 D3 D4 D5. User Manual & Installation Guide

Primare A32 Amplifier User Guide


MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

LF442 Dual Low Power JFET Input Operational Amplifier

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

DA-Type Socket Assemblies

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Chapter 6 Specifications

Pre-Amplifier SPA Series

Primare A31.2 Amplifier User Guide

HA Quad, 3.5MHz, Operational Amplifier. Description. Features. Applications. Ordering Information. Pinouts. November 1996

Owner s manual. SDA 2175 Semi Digital Amplifier

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

EC Declaration of Conformity

GUITAR POWER AMPLIFIER U S E R ' S M A N U A L

1 W BTL mono audio amplifier TDA7052

Dual Operational Amplifiers

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SPECIFICATION. DVB-C / Worldwide NIM Tuner

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

Variable Gain 100 MHz Wideband Voltage Amplifier

Instruction Manual. Charge Amplifiers. M68 Series. Manfred Weber

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

PR-E 3 -SMA. Super Low Noise Preamplifier. - Datasheet -

Chapter 5 Specifications

Broadband Power Amplifier

Bosch Communications Systems Get your message across, effectively.

411LA Broadband Power Amplifier

Transducer for Measurement Bridges SCM90, SIGS15

Charge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...

GF 467F FUNCTION GENERATOR. PROTECTED RS232 + (USB OR LAN)* LabVIEW 0,01 Hz to 5 MHz CMos. Specifications. Other specifications

Advanced Test Equipment Rentals ATEC (2832)

High Performance Current Transducer ITL 900-T = A

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

LV3-8 for imc CRONOS-PL/-SL/compact

6500V/µs, Wideband, High-Output-Current, Single- Ended-to-Differential Line Drivers with Enable

CABINET POWERED MIXING CONSOLE

User Manual. imix 63 Stereo mixing preamplifier

TL072 TL072A - TL072B

MCTS II Multi Channel Current Transducer System. Installation Manual

Current Transducer CTSR 1-P = 1A

PowerAmp Design. PowerAmp Design PAD541 COMPACT POWER OP AMP

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

Kistler LabAmp for DynoWare

SPECIFICATIONS for SPEAKER TEST OSCILLATOR Model OG-484

USER MANUAL. GOLDMUND METIS 2 Analog Preamplifier

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

Model 3102D 0-2 kv H.V. Power Supply

PRE16/26 AUDAC PROFESSIONAL AUDIO EQUIPMENT. PRE16/26 6 Channel Pre-Amplifier Single/Double Output Zone. User Manual & Installation Guide

400 MHz Photoreceiver with InGaAs PIN Photodiode

770E DIGITAL MULTIMETER OPERATOR S MANUAL

Ultra Low-Noise Variable Gain Low-Frequency Voltage Amplifier

audionet AMP 1 V2 User s Manual Stereo - Amplifier

Operator s Manual. DA1855A Differential Amplifier

LF151 LF251 - LF351 WIDE BANDWIDTH SINGLE J-FET OPERATIONAL AMPLIFIER

Transcription:

http://www.cgc-instruments.de/ Quadrupole Power Supply Unit QPS400-3 Instruction Manual Document version 1.00, created on 12.07.2004

Technical Data Quadrupole Power Supply Unit 3 400 V QPS400-3 Version 1.00 2/10

Technical Data Technical Data Characteristics Precise high-voltage amplifier for electrodynamical quadrupole traps for micro- and nanoparticles DC accuracy Extremely low temperature coefficient of amplification High bandwidth Low noise Temporally short-circuit proof 19" case Input Input voltage: ±10 V max. Input impedance: 47 kω Signal inputs: 50 Ω BNC plug sockets Output Amplification: AC input: 40 DC inputs: 4 Function: V Top = 40V AC 4V DC V Mid = +40V AC 4V M V Bot = 40V AC + 4V DC Output voltage: ±400 V min. (> 800 V pp ) Output current: ±50 ma max. Output power: 10 W / channel max. Bandwidth: AC input (±10%): 3.5 Hz... > 1 MHz DC inputs (-3dB): DC... 100 khz Power bandwidth: > 100 khz (200 khz typ.) Output offset voltage: < 100 µv Drift of the output voltage: < 1 µv/k Noise (DC-10 MHz): 3 mv eff (typ.) Precision of the amplification at low frequencies: < 200 ppm (100 ppm typ.) 3/10

Technical Data Temperature coefficient of the amplification at low frequencies: < 10 ppm/k (5 ppm/k typ.) Signal outputs: 93 Ω BNC plug sockets Output short circuit duration: 1 s max. Monitor Output Attenuation: 1:40 of the output voltage Output voltage: ±12 V min. Output current: ±20 ma max. Output offset voltage: < 100 µv Drift of the output voltage: < 25 µv/k (5 µv/k typ.) Precision of the attenuation at low frequencies: < 0.2% (0.1% typ.) Temperature coefficient of the attenuation at low frequencies: < 50 ppm/k (25 ppm/k typ.) Bandwidth (±10%): DC... > 1 MHz Signal outputs: 50 Ω BNC plug sockets Output short circuit duration: indefinite Power Supply Rated voltage: 230 V or 115 V ±10% (voltage selector switch) Rated frequency: 50/60 Hz Fuse: T 0.63 A at 230 V, T 1.25 A at 115 V Power consumption: about 70 VA without load, 130 VA max. Main connection: IEC inlet General Dimensions: 2 HU 19" plug-in box for mounting in a 19" cabinet (height: 88 mm, width: 483 mm) depth with heat sink without handles: 265 mm Weight: 6.8 kg 4/10

Technical Data Shipment Content Quadrupole power supply unit QPS400-3 in 19" case Line cord (universal IEC mains lead, length 1.8 m) Output cables (3 pcs. 93 Ω coaxial cable with 93 Ω BNC jacks, length 1.2 m each) Ground wire (flexible wire 1 mm 2 with 4 mm cable eyes, length 2 m) Material for mounting in a 19" cabinet (4 pcs. M6 screws with washers and cage nuts) Instruction manual 5/10

Terminals Terminals The QPS400-3 device is equipped with 3 3 input and output BNC plug sockets and a ground socket (4 mm banana socket) on the front panel and an IEC inlet for the mains connection on the rear panel. Also on the rear panel, a voltage selector switch allows changing the rated mains voltage between 230 V and 115 V. The device fuse is integrated in the IEC inlet. When changing the rated mains voltage, the fuse must be exchanged for one with a value corresponding to the new mains voltage (see Technical Data: Power Supply). Quadrupole Power Supply 3x400V p QPS 400-3 V AC V DC V M Bottom Middle Top Bottom Middle Top Power Input Monitor Output Fig. 1. The terminals and control elements on the front panel of the quadrupole power supply unit QPS400-3. Power: mains switch with signal lamp Input: signal inputs (V AC, V DC, V M ) Monitor: monitor outputs (Bottom, Middle, Top) Output: amplifier outputs (Bottom, Middle, Top) : device ground 6/10

Getting Started Getting Started Before turning on the device, the rated value of the mains voltage must be set and a corresponding fuse must be installed. The device must be properly cooled. The heat sink at the rear panel must not be covered and the fan must be able to supply sufficiently cool air. The temperature of the cases of the amplifier ICs must never exceed 80 C. 7/10

Adjustment Elements Adjustment Elements! This device is shipped to you ready to use. Adjustments should not be necessary. They should be performed only for maintenance purposes or to optimize the frequency response in the case of a special load. Attention: Adjustments can be made by trained personnel only: A wrong setting can damage the device. Manipulation of the device when the case is open is perilous. Even several minutes after turning off the device the capacitors of the power supply unit can be charged to high voltages. Fig. 2. The inner assembly of the quadrupole power supply unit QPS400-3. High-voltage power-supply units (Fig. 3.): left positive, right negative supply voltage, Amplifier (Fig. 4): center. 8/10

Adjustment Elements Fig. 3. Adjustment elements of the high-voltage power-supply units. POT1: adjusting the value of the supply voltage 9/10

Adjustment Elements Fig. 4. Adjustment elements of the amplifier. CT1: frequency compensation of the input stage (balancing the channels) CT2-4: frequency compensation of the monitor outputs POT1-3: compensation of the offset voltage of the monitor outputs CT5-7, POT4-6: frequency compensation of the main amplifier 10/10