- James Kennedy
- 6 years ago
- Views:
Transcription
1 1 of 6 03/12/ : HAMEG > Products > Accessories > Probes P R O B E S H Z * AC/ DC Current Clamps This AC/DC Current Probe is used to measure currents from 1mA to 30 A over a broad frequency range. The measurement principle is based on the Hall Effect that registers the magnetic field generated by the current flow. Even for complex waveforms a high degree of measurement accuracy is achieved. The output voltage is proportional to the measured current and well suited to be displayed on an oscilloscope. The current probe complies with the safety standards defined in IEC/EN Measurement range: ±30 A DC / 20 A AC Accuracy: ±1% ±2mA Frequency range: DC to 100 khz Resolution: 1 ma Output voltage: 100 mv/a Load impedance: > 100 kω Voltage stability: 3.7 kv / 50 Hz / 1 minute Connection: BNC-Cable, 2 m * Product discontinued; Successor: HZO50 H Z O 4 0 Differential Technical specifications at 23 C ±2 C 200MHz Rise time (10 90%): 1.75ns Gain accuracy ±1% Max. Input Voltage per Input: ±60V Max. Differential Input Voltage (DC + ±20V peak AC): Max. Common Mode Input Voltage: ±60V Input impedance Between Inputs: 1MΩ II 3.5pF Each Input to Ground: 500kΩ II 7pF Output Voltage (into 50Ω): ±2V Offset (typical) ±2mV CMRR (typical): -80dB at 60Hz -50dB at 10MHz Battery life (typical): 7.5h Input for an external power supply: USB Power adapter cable (5 9V DC /200mA) H Z O 4 1 Differential Probes 10:1 Professional articles Technical specifications at 23 C ±2 C 800MHz Rise time (10 90%): 437ps Gain accuracy ±2% Max. Input Voltage per Input: ±40V Max. Differential Input Voltage (DC + ±15V peak AC): Max. Common Mode Input Voltage: ±30V Input impedance Between Inputs: 200kΩ II 1pF Each Input to Ground: 100kΩ II 2pF Output Voltage (into 50Ω): ±1.5V Offset (typical) ±5mV
2 2 of 6 03/12/ :56 CMRR (typical): -60dB at 60Hz -15dB at 500MHz" Battery life (typical): 4.5h Input for an external power supply: USB Power adapter cable (5 9V DC /300mA) H Z O 5 0 AC/DC Current Probe 30A This AC/DC current probe is used to measure currents from 1mA to 30 A over a broad frequency range. The measurement principle is based on the Hall Effect that registers the magnetic field generated by the current flow. Even for complex waveforms a high degree of measurement accuracy is achieved. The output voltage is proportional to the measured current and well suited to be displayed on an oscilloscope. The current probe complies with the safety standards defined in IEC/EN Specifications Measurement range: Accuracy: Resolution: Output voltage: Load impedance: Max. Voltage: Output cable/connector: 2m (50Ω)/BNC II H Z O 5 1 ± 20 A rms /30A p ± 1% from measurement value ± 2mA DC 100 khz (0,5 db) ± 1mA 100mV/A 100 kω II 100 pf 300 V rms (AC or DC) AC/ DC Current Probe 100/ 1000A This AC/DC current probe is used to measure currents from 100mA to 1000A over a broad frequency range. The measurement principle is based on the Hall Effect that registers the magnetic field generated by the current flow. Even for complex waveforms a high degree of measurement accuracy is achieved. The output voltage is proportional to the measured current and well suited to be displayed on an oscilloscope. The current probe complies with the safety standards defined in IEC/EN Specifications Specifications Measurement range: Accuracy: Resolution: Output Voltage: Load impedance: Max. Voltage: Output cable/connector: 2m (50Ω)/BNC II H Z ±100A rms /1000A rms ±1% from measurement value ±0.1A/±0.5A DC 20kHz ±100mA/±500mA 10mV/A/1mV/A >100kΩ II 100pF 300V rms (AC or DC) 350MHz <1.0ns Input impedance: 10MΩ II 12pF Max. Voltage: 400V (DC + peak AC) RF compensation: 2 Trimmer Cable length: 1.2m H Z MHz <700ps Input impedance: 10MΩ II 9.5pF Max. Voltage: 400V (DC + peak AC) RF compensation: 2 Trimmer
3 3 of 6 03/12/ :56 Cable length: 1.3m Professional articles H Z MHz <1.4ns Input impedance: 10MΩ II 12pF Max. Voltage: 400V (DC + peak AC) RF compensation: 2 Trimmer Cable length: 1.2m H Z 5 1 Attenuation ratio 10:1 Bandwidth 150MHz Rise time <2.4ns Input impedance 10MΩ II 12pF Max. Voltage 600V (DC + peak AC) RF compensation: 1 Trimmer Cable length 1.2 m H Z 5 2 Attenuation ratio 10:1 Bandwidth 250MHz Rise time <1.4ns Input impedance 10MΩ II 10pF Max. Voltage 600V (DC + peak AC) LF compensation 1 Trimmer RF compensation 2 Trimmer Cable length 1.2 m H Z 5 3 Probe 100:1 Attenuation ratio 100:1 Bandwidth 100MHz Rise time <3.5ns Input impedance 100MΩ II 4.5pF Max. Voltage 1200V (DC + peak AC) LF compensation 1 Trimmer Cable length 1.2 m H Z Probe 1:1 / 10:1 Attenuation ratio 1:1 Switchable 10:1 Bandwidth 10/100MHz Rise time 35/3.5 ns Input impedance 1/10 MΩ II 82/12 pf Max. voltage (10:1) 600 V (DC + peak AC) LF compensation 1 Trimmer at 10:1
4 4 of 6 03/12/ :56 RF compensation 2 Trimmer at 10:1 Cable length 1.2 m H Z O 2 0 Probe 1000:1 Attenuation ratio: 1000:1 400MHz 900 ps Input impedance: 50 MΩ II 7.5 pf Max. Voltage: 1000 V rms RF compensation: 1 Trimmer Cable length: 1.3m I H Z O 3 0 Active 1GHz 600 ps Input impedance: 1MΩ II 0.9 pf Max. Input voltage: 20 V Input Dynamic Range: ± 8 V Cable length: 1.3m Oscilloscope Input Coupling: 50Ω External Power Supply included Professional articles H Z O MHz <1.4 ns Input impedance: 10 MΩ II 15 pf Max. Voltage: 400 V (DC + peak AC) RF compensation: 2 Trimmers Cable length: 1.2 m Probe factor identification: automatically after plugging
5 5 of 6 03/12/ :56 H Z Differential Probe 20:1 / 200:1 Technical specifications at 23 C ± 2 C Differential input voltage (DC + peak AC) ±700V max.: Max. input voltage per input: 600V rms Attenuation ratio: 20:1 Selectable: 200:1 30/40MHz 12/9ns Input impedance: 8MΩ II 1.2pF Output impedance: 50Ω Max. output Voltage: ±3.5V at 1MΩ Max. noise: 2mV Accuracy after 1min: ±3% (18 30 C) Common mode rejection DC/AC 1MHz: 70dB/>50dB Inputs (CAT III): 2 safety connectors Input leads: 2 test leads 50cm with spring hooks Input for an external power supply: 12 14V dc /30mA H Z Differential Probe 1:1/ 10:1 Technical specifications at 23 C ± 2 C Differential input voltage (DC + peak AC) ±3,5V/35V max.: Max. input voltage per input: 100V rms Attenuation ratio: 1:1 Selectable: 10:1 30/40MHz 12/9ns Input impedance: 8MΩ II 1.2pF Output impedance: 50Ω Max. output Voltage: ±3.5V at 1MΩ Max. background noise at x1: <8mV rms at x10: <2mV rms Accuracy after 1min: ±3% (18 30 C) Common mode rejection DC/AC 1MHz: 70dB/>50dB Inputs (CAT III): 2 safety connectors Input leads: 2 test leads 50cm with spring hooks Input for an external power supply: 12 14V dc /30mA
6 6 of 6 03/12/ :56 H Z Differential Probe 100:1/ 1000:1 Technical specifications at 23 C ± 2 C Differential input voltage (AC rms ): 1000V (DC + peak AC) max.: ±1400V*) Max. input voltage per input: ±1400V*) Attenuation ratio: 100:1 Selectable: 1000:1 20/30MHz 17/12ns Input impedance: 60MΩ II 1.5pF Output impedance: 50Ω Max. output Voltage: ±1.5V at 1MΩ Max. background noise: 2mV Accuracy after 1min: ±3% (18 30 C) Common mode rejection DC/AC 1MHz: 70dB/>50dB Inputs (CAT III): 2 safety connectors Input leads: 2 test leads 75cm with safety test clips Input for an external power supply: 12 14V dc /30mA *) due to test clip 1000 V CAT III 2012 HAMEG Instruments GmbH Last Updated
BumbleBee. High Voltage Differential Probe Ord.-No: Features:
High Voltage Differential Probe Ord.-No: 880-102-501 Features: 2000 V rms Measurement Category I, 6000 V transient Overvoltage 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating
More informationsupplies and frequency converters. BumbleBee is also very effective in fast transient measurements
High Voltage Differential Probe Order-No: 880-102-501 Features: 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating Temperatures (0 C to +50 C) High CMRR 4 Mode Attenuation Useable
More informationTA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.
TA041 25 MHz ±700 V Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2-031 CAT III, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING
More informationTT-SI MHz Active Differential Probe
INSTRUCTION MANUAL TT-SI 9110 100MHz Active Differential Probe These probe is in compliance with EN61010-031:2002+A1:2008 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this manual:
More informationTT-SI 9001 / TT-SI MHz Active Differential Probes
INSTRUCTION MANUAL TT-SI 9001 / TT-SI 9002 25MHz Active Differential Probes These probes are in compliance with IEC-61010-031 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this
More informationTT-SI MHz Active Differential Probe
INSTRUCTION MANUAL TT-SI 9101 100MHz Active Differential Probe These probe is in compliance with IEC-61010-031 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this manual: WARNING.
More informationTA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.
TA043 100 MHz x10/x100 Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2 031 CAT III, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING
More informationDC MHZ PXI Differential Instrumentation Amplifier
DC - 100 MHZ PXI Differential Instrumentation Amplifier Differential 100 V Common Mode Input DC - 100 MHz Bandwidth AC/DC Coupling Programmable Attenuation/Gain/ Offset 9 nv/ Input Noise 50 Ω Output Impedance
More informationDataSheet SIGLENT Series Probe
DataSheet SIGLENT Series Probe Passive Probe Parameter PB470 PP510 PP215 PP430 Attenuation Rate 1 X/10 X 1 X/10 X 1 X/10 X 1 X/10 X Bandwidth 10 X: DC-70 MHz 10 X: DC-100 MHz 10 X: DC-200 MHz 10 X: DC-300
More informationE Series 9.00 (1/2) E series
Clamp-on AC/DC current probes E Series The clamps use Hall effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. The elongated, narrow design of these clamps
More informationTA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.
TA046 800 MHz ±30 V Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2-031 CAT I, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING Warning
More informationHigh Voltage Differential Probes HVD3605, HVD3206 HVD310x
High Voltage Differential Probes HVD3605, HVD3206 HVD310x Key Features 1 kv, 2 kv, 6 kv CAT safety rated models World s only 1500 Vdc safety rated probe per IEC/EN 61010-031:2015 Widest differential voltage
More informationTT-SI MHz DIFFERENTIAL PROBE
TT-SI 9110 100MHz DIFFERENTIAL PROBE USER S MANUAL This probe is in compliance with IEC-1010.1, IEC - 1010. 2-031 CATⅢ, Pollution Degree 2. 1. Safety Terms and Symbols Terms appear in this manual: WARNING.
More informationCX1100 Series Current and Differential Sensors
DATA SHEET CX00 Series Current and Differential Sensors CX0A Current Sensor, Single Channel CX0A Current Sensor, Dual Channel CX03A Current Sensor, Low Side CX04A Current Sensor, Selectable Resistive Sensor
More informationPre-Amplifier SPA Series
Pre-Amplifier SPA Series External Pre-Amplifier for all A/D cards Low noise/high gain Allows to acquire smallest signals with high resolution 5 different versions 20 db to 60 db gain up to 2 GHz bandwidth
More informationFor model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro
HIGH FREQUENCE HIGH VOLTAGE PROBE INSTRUCTION MANUAL For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro TABLE OF CONTENTS 1. SPECIFICATIONS 2. SAFETY PRECAUTIONS 3. OPERATION 4. COMPENSATION ADJUSTMENT
More informationHigh Voltage Differential Probes HVD3605A, HVD3206A HVD310xA
High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA Key Features 1 kv, 2 kv, 6 kv CAT safety rated models Widest differential voltage ranges available Exceptional common-mode rejection ratio (CMRR)
More information1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation
More informationMD 200A High voltage differential probe
1 MD 200A High voltage differential probe User Manual 601-265B MD 200A High voltage differential probe User Manual MD 200A high voltage differential probe contents 1 Safety terms and symbols 5 2 Safety
More informationN2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes
N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet Oscilloscope users often need to make floating measurements where neither point of the measurement is at earth
More informationVariable-Gain High Speed Current Amplifier
Features Transimpedance (gain) switchable from 1 x 10 2 to 1 x 10 8 V/A Bandwidth from DC up to 200 MHz Upper cut-off frequency switchable to 1 MHz, 10 MHz or full bandwidth Switchable AC/DC coupling Adjustable
More informationOscilloscope Probes and Accessories
Oscilloscope Probes and Accessories Pomona s oscilloscope probes give you the full range you need. Designed, rated, and specified to match the bandwidth of your instrument, they provide you with full voltage
More informationAC/DC current clamps (1/2) E N series
AC/DC current clamps The clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. These clamps' narrow, elongated design makes them ideal areas
More information10.00 (1/2) PAC series
Clamp-on AC/DC current probes PAC Series The is a range of professional AC/DC clamp-on current probes designed to meet the very latest in safety and performance standards. There are two different jaw designs
More information1587/1577 Insulation Multimeters
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
More informationCurrent clamps for AC current
Current clamps for AC current Y series The Y series clamps are designed to be both rugged and versatile whilst remaining easy to use. The jaws are designed so that the clamps can be hooked onto cables
More information9 Specifications. Specifications NOMINAL CHARACTERISTICS
9 Specifications Specifications NOMINAL CHARACTERISTICS WARRANTED CHARACTERISTICS Nominal characteristics describe parameters and attributes that are guaranteed by design, but do not have associated tolerances.
More informationKeysight Technologies InfiniiVision Oscilloscope Probes and Accessories
Keysight Technologies InfiniiVision Oscilloscope Probes and Accessories For 2000 X-, 3000A/T X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series Selection Guide Introduction To achieve the best results from
More informationN2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes
N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet Oscilloscope users often need to make floating measurements where neither point of the measurement is at earth
More informationOutput Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.
3 Channel Digital Storage Oscilloscope (DSO) Instrument VERTICAL SPECIFICATIONS Analogue Bandwidth (-3dB) Bandwidth Limiting Rise time (10% to 90%, calculated) Input ranges (full scale) Input sensitivity
More informationWide-band Models from DC to 100 MHz
CLAMP ON PROBE 327 series AC/DC CURRENT SENSOR CT686 series 99 Washington Street Melrose, MA 2176 Phone 781-665-14 Toll Free 1-8-517-8431 Visit us at www.testequipmentdepot.com Wide-band Models from DC
More informationVariable-Gain High Speed Current Amplifier
Features Transimpedance (Gain) Switchable from 1 x 10 2 to 1 x 10 8 V/A Bandwidth from DC up to 200 MHz Upper Cut-Off Frequency Switchable to 1 MHz, 10 MHz or Full Bandwidth Switchable AC/DC Coupling Adjustable
More informationPRELIMINARY DATA. Fiber Optic Isolated Voltage Probe. GE50 Gate Explorer FEATURES
Fiber Optic Isolated Voltage Probe. GE50 Gate Explorer FEATURES 50MHz bandwidth Battery powered, connects to any oscilloscope via BNC Standby feature for low power consumption ± 25V measuring range Excellent
More informationPHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design
High impedance passive probe Features: CeramCore TM Hybrid Probe Modular Construction Coaxial Design Interchangeable Spring Contact Tip Certificate of Calibration available on request Read-out BNC Connector
More informationProbes and Accessories
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Probes and Accessories Your Guide to Selecting the Right Probe Measurement Accuracy
More informationSupplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments
High impedance passive probe Features: CeramCore TM hybrid probe Modular construction Coaxial design Interchangeable spring contact tip Certificate of calibration available on request Read-out BNC connector
More informationKeysight Technologies InfiniiVision Oscilloscope Probes and Accessories
Keysight Technologies InfiniiVision Oscilloscope Probes and Accessories For 1000 X-, 2000 X-, 3000A/T X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series Selection Guide 02 Keysight InfiniiVision Oscilloscope
More informationSpecifications for DS1000CA Series
Revised December, 2009 RIGOL Specifications for DS1000CA Series All specifications apply to the DS1000CA Series Oscilloscopes unless noted otherwise. To meet these specifications, two conditions must first
More informationFlexible AC current probes
Flexible AC current probes Making use of the principle of Rogowski coils, the MiniFLEX models are flexible sensors offering a wide dynamic range for measuring AC intensities and viewing high-speed current
More informationKeysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet
Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes Data Sheet Introduction The Keysight Technologies, Inc. N2792A/93A and N2818A/19A differential probes provide the
More informationVariable Gain 100 MHz Wideband Voltage Amplifier
Features 10 to 60 db, Switchable in 10 db Steps Bandwidth DC... 100 MHz, Switchable to 10 MHz Built-In Temperature Compensation for Low Drift of 0.6 µv/k 2.5 nv/ Hz Input Noise Switchable AC/DC-Coupling
More informationWide-band Models from DC to 100 MHz
CLAMP SENSOR Wide-band Models from DC to 1 MHz 3273-5 - 3276 CLAMP ON PROBES http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available
More informationAnalog Arts SG985 SG884 SG834 SG814 Product Specifications [1]
www.analogarts.com Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1] 1. These models include: an oscilloscope, a spectrum analyzer, a data recorder, a frequency & phase meter, and an arbitrary
More informationQuick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series
Quick Start RSDPB5000/RSDPB4000 High Voltage Differential Probe Series 2 Please read this manual carefully before use Safety precautions 1. Be cautious of an electric shock 2. Pay attention to the maximum
More informationDS 6000 Specifications
DS 6000 Specifications All the specifications are guaranteed except the parameters marked with Typical and the oscilloscope needs to operate for more than 30 minutes under the specified operation temperature.
More informationCPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A
The CPCO Series (160mm aperture) Current Probes are Clamp On current sensors capable of measuring ac and dc currents. The Current Probe splits along a diameter allowing easy installation to existing cables
More informationAgilent Technologies 5000, 6000 and 7000 Series InfiniiVision Oscilloscope Probes and Accessories
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Agilent N2772A Product Page Agilent Technologies 5000, 6000 and 7000
More informationCPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,
The CPCO Series (160mm) Current Probes are Clamp On current sensors capable of measuring ac and dc currents available in ranges of ±4000A ±8000A, ±12000A with an accuracy of +/-1% and non-linearity of
More informationAgilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide
User s Guide Publication Number E2695-92000 June 2003 Copyright Agilent Technologies 2003 All Rights Reserved. Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes Agilent
More informationAnalog Arts SL987 SL957 SL937 SL917 Product Specifications [1]
www.analogarts.com Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1] 1. These models include: an oscilloscope, a spectrum analyzer, a data recorder, a frequency & phase meter, an arbitrary
More informationSERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.
Pinces Current ampèremetriques clamps for AC/DC pour current courant AC SERIE E N The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over
More information87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.
20 Amplifiers 83020A microwave 875A microwave 8308A microwave 8307A microwave 83006A microwave 8705C preamplifier 8705B preamplifier 83050/5A microwave The Agilent 83006/07/08/020/050/05A test s offer
More informationHigh-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A
High-voltage Differential Probes TMDP0200 - THDP0200 - THDP0100 - P5200A - P5202A - P5205A - P5210A BNC interface (P5200A probes) TekVPI interface (TMDP and THDP Series probes) TekProbe interface (P5202A,
More information400 MHz Passive High-Voltage Probe R&S RT-ZH
Manual 400 MHz Passive High-Voltage Probe R&S RT-ZH11 1409.7737.02 Printed in Germany Test and Measurment Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit
More information200 MHz Variable Gain Photoreceiver
The image shows model -FST with 1.035-40 threaded flange and coupler ring. Features Applications Adjustable transimpedance gain from 10 2 to 10 8 V/A Wide bandwidth up to 200 MHz Si-PIN photodiode covering
More informationVariable Gain Low Frequency Voltage Amplifier
Features Applications 20 to 80 db, Switchable in 20 db Steps Bipolar Input Stage, Recommended for Low Impedance Sources Smaller than 1 kω Single Ended and True Differential Input Models Bandwidth DC -
More informationWorld-Class Accuracy & Measurement Range (40 Conventional Models)
AC/DC CURRENT SENSOR CT6904 Ultra-High Performance AC/DC Current Sensor World-Class Accuracy & Measurement Range (40 Conventional Models) 500 A (rms) Rated for measurement of large currents 4 MHz (±3 db)
More informationData sheet IDM 99III Digital Multimeter
RS Stock No. 7575116 Data sheet IDM 99III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.08% basic DCV accuracy
More informationAnalog Arts SF990 SF880 SF830 Product Specifications
1 www.analogarts.com Analog Arts SF990 SF880 SF830 Product Specifications Analog Arts reserves the right to change, modify, add or delete portions of any one of its specifications at any time, without
More informationTablet Oscilloscope Data Sheet
Tablet Oscilloscope Data Sheet For tbook Series 2015.1 Shenzhen Micsig Instruments Co., Ltd. Model TO102 TO102A TO104 TO104A TO152 TO152A Channels 2 2 4 4 2 2 Bandwidth 100M 100M 100M 100M 150M 150M Risetime
More informationENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph
ENGLISH Datasheet Stock No. 123-3249 RS PRO IDM 99III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.08% basic
More informationAnalog Arts SF900 SF650 SF610 Product Specifications
www.analogarts.com Analog Arts SF900 SF650 SF610 Product Specifications Analog Arts reserves the right to change, modify, add or delete portions of any one of its specifications at any time, without prior
More informationPT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION
PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 INSTRUCTION MANUAL General Safety Instructions: Read the following safety instructions to avoid injury and prevent damage to this product
More information1507/1503. Insulation Testers. Technical Data. Features and benefits:
1507/1503 Insulation Testers Technical Data The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting,
More informationPHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design
High impedance passive probe Features: CeramCore TM hybrid probe Modular construction Coaxial design Interchangeable spring contact tip Certificate of calibration available on request Read-out BNC connector
More informationKeysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet
Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet 02 Keysight N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes
More informationDSO 3000 Series Oscilloscope
Key Features 200 / 100 / 70MHz bandwidths Arbitrary/Function Waveform Generator + Synchronizing Signal + External Trigger 1GSa/s Real Time sample rate 7 large color display, WVGA (800x480) 2 Channels,
More informationVariable Gain Photoreceiver - Fast Optical Power Meter
The picture shows model -FC with fiber optic input. Features Conversion gain switchable from 1 x 10 3 to 1 x 10 11 V/W InGaAs-PIN detector Spectral range 900-1700 nm Calibrated at 1550 nm (fiber optic
More informationS5101 Handheld Radio Communication Analyzer
is the ideal radio tester for laboratory, production, service and maintenance use. It combines radio frequency emission, reception analysis, audio source, analyzer, etc. all into one unit. It can measure
More informationSpecification for Conducted Emission Test
1 of 10 1. EMI Receiver Frequency range 9kHz 7.0 GHz Measurement time per frequency 10 µs to 100 s time sweep, span = 0 Hz - 1 µs to 16000 s Sweep time in steps of 5 % frequency sweep, span 10 Hz - 2.5
More informationRIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc
User s Guide RP1000D Series High Voltage Differential Probe Feb. 2013 RIGOL Technologies, Inc Guaranty and Declaration Copyright 2012 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information
More informationData sheet IDM 98III Digital Multimeter
RS Stock No. 7575110 Data sheet IDM 98III Digital Multimeter FEATURE: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.1% basic DCV accuracy
More informationKeysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note
Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer Application Note Introduction This note details the input impedance of the U8903B Audio Analyzer, and shows that this needs to
More informationAP034-OM-E Rev D ISSUED: January 2000 ²
3HUIRUPDQFH9HULILFDWLRQ 3HUIRUPDQFH9HULILFDWLRQ This procedure can be used to verify the warranted characteristics of the AP034 Active Differential Probe. The recommended calibration interval for the model
More informationInfiniium Series Oscilloscope Probes, Accessories, and Options
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Agilent 1153A Product Info Page Infiniium Series Oscilloscope Probes,
More informationDual operational amplifier
DESCRIPTION The 77 is a pair of high-performance monolithic operational amplifiers constructed on a single silicon chip. High common-mode voltage range and absence of latch-up make the 77 ideal for use
More informationPRODUCTS PINTEK. Pintek Electronics Co., Ltd Condensed Catalog.
PRODUCTS Pintek Electronics Co., Ltd 2016-17 Condensed Catalog www.pintek.com.tw TABLE OF CONTENTS Differential Probe Current Probe High Voltage Amplifier LCR Meter DC Power Supply Milli-OHM Meter Programable
More informationENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph
ENGLISH Datasheet Stock No. 123-3248 RS PRO IDM 98III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.1% basic
More informationAgilent IniniiVision Oscilloscope Probes and Accessories
Agilent IniniiVision Oscilloscope Probes and Accessories For 2000 X-, 3000 X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series Selection Guide Data Sheet To achieve the best results from your scope, you
More informationHA-2520, HA-2522, HA-2525
HA-, HA-, HA- Data Sheet September 99 File Number 9. MHz, High Slew Rate, Uncompensated, High Input Impedance, Operational Amplifiers HA-// comprise a series of operational amplifiers delivering an unsurpassed
More informationProbing for oscilloscope
Probing for oscilloscope Agenda - Notion de sonde en oscilloscopie - Structure des différentes sondes - Passives - Actives - Logiques - Différentielles - Comment choisir la bonne sonde - Nouvelle technologie
More informationAC Current Probes CT1 CT2 CT6 Data Sheet
View at www.testequipmentdepot.com AC Current Probes CT1 CT2 CT6 Data Sheet Features & Benefits High Bandwidth Ultra-low Inductance Very Small Form Factor Characterize Current Waveforms up to
More informationChapter 6 Specifications
RIGOL This chapter lists the technical specifications and general specifications of the RF signal generator. The technical specifications are valid when the instrument is within the calibration period,
More informationGF 467F FUNCTION GENERATOR. PROTECTED RS232 + (USB OR LAN)* LabVIEW 0,01 Hz to 5 MHz CMos. Specifications. Other specifications
FUNCTION GENERATOR EAN CODE : 3760244880468 5 MHZ+RS232++(USB or LAN)* GF 467F COMPLETE : Reciprocal frequency counter 50 MHz. - Internal linear or logarithmic sweep, and external VCF or FM modulation.
More informationSchlöder GmbH - EMC Test and Measurement Systems Model #
Schlöder GmbH - EMC Test and Measurement Systems Model # Product Description IEC / EN 61000-4 - 2 ESD SESD 216 ESD generator 10 kv CON / 16,5 kv AIR acc. to IEC 61000-4-2, 150 pf / 330 ohm SESD 230 ESD
More informationPMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip
High impedance passive probe Features: CeramCore TM Hybrid Probe Modular Construction Coaxial Design Interchangeable Spring Contact Tip IC Contacting System 0.8 to 1.27 mm pitch Unbreakable Reed Switch
More informationVoltage Sensors URV5-Z
Data sheet Version 05.00 Voltage Sensors URV5-Z May 2005 Universal voltage measurements from RF to microwaves The voltage sensors of the URV5-Z series are indispensable tools in RF and microwave laboratories,
More informationSimple measurement at the best price
Simple measurement at the best price n Multimeters n Clamp-on multimeters n Electrical safety testers n Testers n Environmental measurements n Laboratory instruments 01/2018 CONTENTS Multimeters page 3
More informationDECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY Manufacturer's Name: Transmille Ltd. Manufacturer's Address: Unit 4, Select Business Centre Lodge Road Staplehurst TN12 0QW. United Kingdom. Declares, that the product Product
More informationAgilent U2701A and U2702A USB Modular Oscilloscope. Data Sheet
Agilent U2701A and U2702A USB Modular Oscilloscope Data Sheet Features 100 MHz and 200 MHz bandwidths Up to 1GSa/s maximum sample rate 32 Mpts of waveform memory Compact and portable size 117.00 mm x 180.00
More informationFluke 192/196/199. ScopeMeter. Users Manual
Fluke 192/196/199 ScopeMeter Users Manual 4822 872 00983 October 2000, Rev.2, 2/01 2000 Fluke Corporation. All rights reserved. Printed in the Netherlands. All product names are trademarks of their respective
More informationHZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III
HZ 115 Differential probe for oscilloscopes 1500 V input voltage max. 30 MHz bandwidth x 100 and x 1000 attenuation 50 db CMRR (1MHz) User-friendliness through a microcontroller Automatic Switch-off Beep
More informationInfiniiVision Oscilloscope Probes and Accessories For 2000 X-, 3000 X-,
InfiniiVision Oscilloscope Probes and Accessories For 2000 X-, 3000 X-, 4000 X-, 5000, 6000, and 7000 Series Selection Guide Data Sheet To achieve the best results from your scope, you need the right probes
More information5MHz FUNCTION GENERATOR
5MHz FUNCTION GENERATOR MODEL GF-8056 User s Manual Elenco TM Electronics, Inc. Copyright 2004 by Elenco TM Electronics, Inc. All rights reserved. 753117 No part of this book shall be reproduced by any
More information5MHz FUNCTION GENERATOR
5MHz FUNCTION GENERATOR MODEL GF-8056 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com User s Manual Elenco TM Electronics, Inc.
More informationModels 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument
Tunable Active Single Channel Certified Filter Instrument Description Frequency Devices instruments are single channel; 8-pole low-pass or high-pass, front panel tunable filter instruments. The controls
More informationVariable Gain Photoreceiver Fast Optical Power Meter
The picture shows model -FC with fiber optic input. Features Si-PIN detector, active area 1.1 x 1.1 mm 2 Spectral range 190-1000 nm Very low noise, NEP down to 17 fw/ Hz Bandwidth up to 500 khz Conversion
More informationPMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design
High impedance passive probe Features: CeramCore TM Hybrid Probe Modular Construction Coaxial Design Interchangeable Spring Contact Tip IC Contacting System 0.8 to 1.27 mm pitch The PMT 211A-RO is a 250
More informationMeasurement and Analysis for Switchmode Power Design
Measurement and Analysis for Switchmode Power Design Switched Mode Power Supply Measurements AC Input Power measurements Safe operating area Harmonics and compliance Efficiency Switching Transistor Losses
More informationEMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing
EMC PARTNER DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management
More information