General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

Similar documents
Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

BIODEX MULTI- JOINT SYSTEM

HeRO duet

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

Powered Traction Unit OPERATION MANUAL

English

Biological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.

D C 01/2019 3

Technical Specifications Micromedical VisualEyes 505 by Interacoustics

VN415/VO425 Specifications

Technical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.

Nursing Beds with Dewert drive system

Rolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual

PHYSIOFLOW Q-LINK TM

USER MANUAL MHS-2500I. Please take time to read these instructions before starting to use the scale. Version /17

User Instruction Computer Assisted Local Analgesia. 337 Marion, Le Gardeur QC, Canada, J5Z 4W8

TH008F Multi-function Infrared Forehead Thermometer

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

USER MANUAL M-200. Please take time to read these instructions before starting to use the scale. Version /06

Operating Manual Infrared thermometer

DENTAL X-RAY OPERATOR'S INSTRUCTIONS. (for USA) Wall Mount Type...WK

#

INTRODUCTION. 4 SAFETY INSTRUCTIONS. 5 ABOUT THIS DEVICE. 6 FIRST OPERATION. 7 THE DISPLAY. 8 ATTACHING THE WRIST SLEEVE. 9 CORRECT MEASUREMENT.

SAVI SCOUT Surgical Guidance System. Console Operation Manual

Not for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT

INSTALLATION MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

H2 Check Operating Manual

M-400 M-410 M-420 M-430

The following symbol indicates that the device is MR-unsafe:

: 0089 GTIN

`bob`=p=^åèìáëáíáçå=råáí=bma

`bob`=p=^åèìáëáíáçå=råáí

The following languages can be found on our website: French. German. Spanish. Italian. Swedish. Portuguese. Russian. Dutch.

Rotating Anode X-Ray Tube Housing Assembly. General Data

Ceiling Model Ceiling Model for LEDview Plus and Heliodent Plus. Installation Requirements. New as of: English

INSTRUCTIONS FOR YOUR NEW PLASMAFLOW. Vascular Therapy System (Compressible Limb Sleeve Device)

The Symbol means that the Vet-Tech (200, 250 or 300HF) system intentionally applies some radioelectric energy for diagnostic or treatment purposes.

IEC Second Edition

SJM MRI Activator. Handheld Device. User's Manual. Model EX4000

Central Blood Pressure Meter Model cbp301. Operating Manual

Operator s Manual External Remote Controller (ERC)

MINISCAV Vacuum Pump Manual

OPERATOR'S INSTRUCTIONS DENTAL X-RAY MODEL 096

L NKTEMP. Non-contact. Infrared Thermometer. User Manual LMP001

OPERATOR'S INSTRUCTIONS DX-073 DENTAL X-RAY

#0086.

WRIST BLOOD PRESSURE MONITOR

Relief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak.

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Introducing the Pixium Portable System

Exergen TAT 5000S RS232 TTL Supplemental Instructions for Use

OPERATOR S INSTRUCTIONS (for USA & Canada)

USER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus

Osmolarity System USER MANUAL FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES. osdcare.com

Multi-Control Panel for built-in system. Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001

National Voluntary Laboratory Accreditation Program

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Laboratory Accreditation Programmes

GTIN:

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

Transcutaneous Electrical Nerve Stimulator

OPERATOR S MANUAL AN APPLIED DIGITAL COMPANY

Welch Allyn Home Scale (T- RPM-SCALE100)

AUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL

American National Standard for Methods of Measurement. Frequency allocations and radio treaty matters; general rules and regulations

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

EMC standards. Presented by: Karim Loukil & Kaïs Siala

High precision measurement system for current and voltage IHC-A/B-RM01/03

ENG en. Operating instructions. Iris Magneton MF Wellness therapy

OPSJ1900 J1900 Open Pluggable Specification Products

National Voluntary Laboratory Accreditation Program

BodyclockStimplusManual.qx8_Layout 1 17/08/ :53 Page 1. Body Clock Stimplus. Instructions for use

Power Quality Issues from an EMC Point of View

TEST REPORT... 1 CONTENT...

User instructions for the ABI-system 100

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

R&TTE Testing For EU Market

EMC Test report for LED Panel Light Models , , , , ,

User Manual. Glass Body Fat Analyzer LS203-B. version:1.0

National Voluntary Laboratory Accreditation Program

CardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring. Technical Manual

Compressor Nebulizer. Model No: 9R-021 series. Please read the instruction manual before use.

DIGITAL BLUETOOTH THEROMETER PBT

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

ibed Locator Model 5212

Draft. User s Manual. Transmitter Model EX1150

This product may malfunction due to electromagnetic waves caused by portable

Transmitter Model EX1100, EX1100W. User's Manual

AS/NZS CISPR 14.2:2015

RS Pro ENGLISH. Datasheet

POCKET AIR. Portable Nebulizer. Instruction Manual MBPN002 / MB / MB05006

National Voluntary Laboratory Accreditation Program

HD STETH TM Quick Start User Guide

National Voluntary Laboratory Accreditation Program

Product Manual N.2 WEARABLE ECG. PRODUCT MANUAL

2015 / 9C EN-00 OSRAM GmbH Marcel-Breuer-Str München Germany. Radio and Telecommunications Terminal Equipment

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

LW3.97-T120. P3.97 Led Wall Display

Transcription:

1. General Safety 1.1 The i-limb ultra and i-limb digits devices are electrical devices, which under certain circumstances could present an electrical shock hazard to the user. Please read the accompanying user manual thoroughly and follow directions stated in the manual to assure maximum safety during charging and operation. 1.2 BS EN 60601-1:2006 1.2.1 Protection against electrical shock Class II 1.2.2 Degree of protection against electrical shock Type BF provides additional protection against electric shock 1.2.3 Degree of protection against ingress of water (IEC 60529:2001) IP40 1.2.4 Not suitable for use in the presence of flammable anesthetic mixture with air or with oxygen or nitrous oxide 1.3 EMI/EMC 1.3.1 Compliance against standard BS EN 60601-1-2:2007 1.4 Radio Spectrum Matters (ERM)/Bluetooth 1.4.1 Compliance against standard EN 301 489-1 V1.8.1 Page: 1 of 7

2. Electromagnetic Compatibility (EMC) 2.1 Important information regarding Electro Magnetic Compatibility (EMC) In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the BS EN 60601-1-2:2007 standard has been implemented. This standard defines levels of electromagnetic emissions for medical devices. The i-limb ultra Device manufactured by Touch Bionics Ltd conforms to this BS EN 60601-1- 2:2007 standard for both immunity and emissions. Refer to further guidance below regarding the EMC environment in which the device should be used. Guidance and manufacturer s declaration electromagnetic emissions i-limb ultra and i-digit devices is intended for use in the electromagnetic environment specified below. The customer or the user of i-limb ultra and i-limb digits devices should assure that it each are used in such an environment. Emissions test Compliance Electromagnetic environment - guidance RF emissions CISPR 11 i-limb ultra and i-limb digits devices use RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 Class B i-limb ultra and i-digit Device is suitable for use in all establishments, including domestic establishments and those directly connected to the public lowvoltage power supply network that supplies buildings used for domestic purposes. Voltage fluctuations/ flicker emissions IEC 61000-3-3 Page: 2 of 7

Guidance and manufacturer s declaration electromagnetic immunity i-limb ultra and i-limb digits devices are intended for use in the electromagnetic environment specified below. The customer or the user of i-limb ultra and i-limb digits devices should assure that each are used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge (ESD) IEC 61000-4-2 ±6 kv contact ±8 kv air ±4 kv contact ±8 kv air Floors should be wood, concrete, or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Portable and mobile RF communications equipment should be used no closer to any part of the i-limb ultra Device, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Electrical fast transient/burst IEC 61000-4-4 No Cables >3m Surge IEC 61000-4-5 Voltage dips, short interruptions and voltage variations on power supply No Cables >30m IEC 61000-4-11 Power frequency (50/ 60 Hz) magnetic field IEC 61000-4-8 3 A/m 3 A/m 50/60Hz Page: 3 of 7

Guidance and manufacturer s declaration electromagnetic immunity i-limb ultra and i-limb digits devices are intended for use in the electromagnetic environment specified below. The customers or the users of i-limb ultra and i-limb digits devices should assure that each are used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000-4-6 Not applicable Not applicable Battery Powered No Cables >3m Portable and mobile RF communications equipment should be used no closer to any part of the i-limb ultra and i-digit including cables, than the recommended separation distance calculated from the equation appropriate to the frequency of the transmitter. Recommended separation distance d = 1.2 P d = 1.2 P 80 MHz to 800 MHz d = 2.3 P 800 MHz to 2.5 GHz Radiated RF IEC 61000-4-3 3 V/m 80 MHz to 2.5 GHz 3 V/m 80 MHz to 2700MHz 1kHz 80% AM Upper frequency extended to 2700MHz) Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol: Note 1: At 80 MHz and 800 MHz, the higher frequency range applies. Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/ cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the i- limb ultra is used exceeds the applicable RF compliance level above, i-limb ultra should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the i-limb ultra. Page: 4 of 7

Recommended separation distance between portable and mobile RF communications equipment and the i-limb ultra device i-limb ultra device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customers or the user of i-limb ultra device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the i-limb ultra device as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter in Watt Separation distance according to frequency of transmitter in meters 150 khz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5GHz d = 1.2 P d = 1.2 P d = 2.3 P 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. Note 1: At 80MHz and 800MHz, the separation distance for the higher frequency range applies. Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. Page: 5 of 7

3. Explanation of Symbols on Technical Label Refer to operating instructions Class II equipment provides double Isolation to protect against electric shock Degree of protection IP40 IP40 Protection against penetration by solid particles with diameters larger than 1 mm. No special protection against penetration by water Batch/Lot/ID Number For the i-limb ultra and i-limb digits device: Each device has a guaranteed unique batch /id number example: UXXXX:YYYY or DXXXX:YYYY U denotes Ultra product, D denotes Digits, The 4 digit number is the unique batch/id for the device and the then the year of manufacture of the device is added (YYYY) WEEE Compliance Catalogue number Manufacturer Keep Dry 4. Customer Service/Contact Information: Page: 6 of 7 Touch Bionics, Unit 3 Ashwood Court, Oakbank Park Way, Livingston EH53 0TH, UK Tel Customer Service: +44 (0) 1506 445 410 Tel: General Enquiries: +44 (0) 1506 438 556

www.touchbionics.com Page: 7 of 7